Team Engineers TEAMLINK 3002 SHDSLteamengineers.in/pdffiles/2Wire_v35_modem.pdf · Configuration...
Transcript of Team Engineers TEAMLINK 3002 SHDSLteamengineers.in/pdffiles/2Wire_v35_modem.pdf · Configuration...
TEAMLINK 3002 SHDSL
2Wire V35 G.SHDSL Modem
TECHNICAL SPECIFICATIONS
G.SHDSL LINE INTERFACE
Line type : 2Wire (single pair operation) twisted copper wire of 0.5mm Diameter
Line Code : TCPAM as per the ITU-T G991.2 ( Annex –A and Annex –B )
Bandwidth : Operates From 64Kbps to 2048Kbps
Line Impedance : 135 Ohms
Transmit Signal Power : 16 dBm +/- 0.5dBm
Operating Range : 6 Kms. on 0.5mm diameter copper cable @ 2.048Mbps operation, data rate
and 11Km on 0.5mm diameter copper cable @ 64Kbps in operation
Line protection : As per ITU-T K20 and K21
Transmit Level : Upto 16dBm
Connector : RJ 45
Surge Protection : Internal and Optional External Surge Protection
Solutions in Connectivity
An ISO 9001 : 2008 Company
Team Engineers
Interface : V35
Data Rates : 2.304 Mbps (n*64 Kbps, n=1 to 36)
Transmit Clock Modes : Internal/External/Recovered from line
Connector : V35 Pin Female Connector
Configuration : Through DIP Switches
Clock Polarity Selection : RXCLK and TXCLK
V35 INTERFACE SPECIFICATIONS
2 Wire Operation
Provides multi stage line protection as per K.20 and K.21
Configuration Through DIP Switches
External Secondary optional Line Protection Device
Long reach up to 11Kms. for standard 64Kbps speed
LED Indications for easy Monitoring
Front Panel Switches for Diagnostics or Loopbacks
Supports 230V AC and 48V DC with the Same Socket
FEATURES
Local Loopback, Digital Loopback and Remote Loopback as per the ITU-T V.54 standard
All loop back tests and BERT should be operated through Front Panel switches
Built in test 511 pattern generation and checking (BERT) for the DSL Line as well as the PCM E1 Checking
End to End Diagnostics and Status Monitoring is through the Embedded Operation Channel EOC without Interrupting the Data
DIAGNOSTICS
TEAMLINK 3002 SHDSL
2Wire V35 G.SHDSL Modem
Solutions in Connectivity
An ISO 9001 : 2008 Company
Team Engineers
Team Engineers Advance Technologies India (P).Ltd
Solutions in Connectivity
An ISO 9001 : 2008 Company
Team Engineers
Modem Configuration Through Dipswitches
MODEM CONFIGURATION AND STATUS MONITORING
TEMPERATURE : -5 To 60 C°
HUMIDITY : Upto 95% non condensing
LINE PROTECTION : As per ITU K.20/K.21 TEC Approval : As per TEC/IR/DCA-18/05.MAR 2013
PWR, MR, COT, DSL LINK, DTR, RTS, PAT, ERR, TST
MODEM LED INDICATIONS
DUAL MODE AC/DC, 230VAC +/- 10% & –48VDC +/-10%
POWER SUPPLY FOR BOTH THE G703 AND V35 MODEM