© MOBATIME TE-800429.06
Installation instructions
METROLINE- industrial clocks, double-sided, round
Before installation of the clock please read the manual carefully.
References to the Instruction Manual
1. The information in this Instruction Manual can be changed at any time without previousnotice.
2. This Instruction Manual has been composed with utmost care, in order to explain all details inrespect of the operation of the product. Should you, nevertheless, have questions or discovererrors in this Manual, please contact us.
3. We do not answer for direct or indirect damages, which could occur, when using this Manual
4. Please read the instructions carefully and start the setting-up of the product, only once youhave correctly understood all information for the installation and of the operation.
5. The installation must only be carried out by skilled staff.
6. It is prohibited to reproduce, to store in a computer system or to transfer this publication in away or another, even part of it. The copyright remains with all the rights with MOSER-BAERAG – CH 3454 Sumiswald / SWITZERLAND.
© MOBATIME 2 / 20 800429.06
List of contentsSeite
Mounting guidelines..............................................................................................................................................31.1 Fastening "DA" "WA" "S" und "ZM" ..........................................................................................................31.2 Building Department / Authority Permit ....................................................................................................31.3 Wall Mounting...........................................................................................................................................41.4 Ceiling Mounting.......................................................................................................................................41.5 Central Pole Mounting ..............................................................................................................................41.6 Open Clock...............................................................................................................................................51.7 Close Clock ..............................................................................................................................................51.8 Cleaning ...................................................................................................................................................5
2. Electrical connections....................................................................................................................................52.1 Mains power supply..................................................................................................................................52.2 Internal connections .................................................................................................................................72.3 Autonomous quartz clocks (QU) ..............................................................................................................72.4 Autonomous clocks with external DCF 77 radio receiver (FWU).............................................................72.5 Autonomous clocks with external GPS-receiver, battery or mains powered (GU)...................................82.6 Slave clocks for minute impulses (A, F) ...................................................................................................82.7 Slave clocks (SAx, SFx) ...........................................................................................................................9
3 Set clock to correct time..............................................................................................................................103.1 Pulse controlled slave clocks (NU 90t / NU 90t SYN) ............................................................................103.2 Self-setting movements..........................................................................................................................10
4 Replacement of lamp and starter................................................................................................................104.1 Opening clock.........................................................................................................................................104.2 Replacement of lamp .............................................................................................................................104.3 Replacement of starter ...........................................................................................................................104.4 Replacement of ballast ...........................................................................................................................104.5 Close clock .............................................................................................................................................104.6 Cleaning .................................................................................................................................................10
5 Valid documents...........................................................................................................................................10
6 Connection diagrams...................................................................................................................................116.1 Battery-driven autonomous clocks (QU, FWU, GU)...............................................................................116.2 Slave clocks for minute pulses without synchronous seconds (A) .........................................................136.3 Slave clocks for minute pulses with synchronous seconds (F) ..............................................................136.4 Slave clocks with MOBALine (SAM, SFM) .............................................................................................146.5 Slave clocks with MOBALine (SAM230, SFM230) .................................................................................146.6 Slave clocks for DCF- 77 radio reception (SAA, SFA) ...........................................................................156.7 Slave clocks for serial telegram synchronization (SAT, SFT) ................................................................156.8 Slave clocks for synchronization over RS-485 (SAS, SFS)....................................................................166.9 Slave cloks for NTP-Synchronization over NCI ......................................................................................176.10 Slave cloks for NTP-Synchronization .....................................................................................................18
© MOBATIME 3 / 20 800429.06
Mounting guidelines
1.1 Fastening "DA" "WA" "S" und "ZM"
Nominal- without illumination
types
with illumination
types
2-seitig 50 cm ML.xxx.50.3xx.xx MLB.xxx.50.3xx.xx
2-seitig 60 cm ML.xxx.60.3xx.xx MLB.xxx.60.3xx.xx
2-seitig 80 cm ML.xxx.80.3xx.xx MLB.xxx.80.3xx.xx
160,5
23
152
o 50
A
239
152-220
o13
90
126
150
186
cable entry Ø 40mm
"DA"
L
"DA"
"WA"
"ZM"
"S"
1.2 Building Department / Authority Permit
If necessary a building department / authority permit should be requested before mounting.
dial- A [mm]50 53460 63480 834
Option “DA“:L [mm] 500 / 600 / 800
© MOBATIME 4 / 20 800429.06
1.3 Wall Mounting
All electrical lines are to be fed through the console (cableentry 40 mm).Prior to any installation works the mains power has tobe disconnected!
Set four bolts or plugs for screws according to the mountingsketch of figure in chapter 1. Feed the cables through theconsole, slide the clock onto the console and adjust the clockface to a vertical position.
Tighten both locking screws (G).
Locking screws (G) M5Hex head wrench 2,5 mm
1.4 Ceiling Mounting
All electrical lines are to be fed through the console (cable entry 40 mm).
Prior to any installation works the mains power has to bedisconnected!
Set four bolts or plugs for screws according to the mounting sketch offigure in chapter 1. Feed the cables through the console, slide the clockonto the console and adjust the clock face to desired angle.
Tighten first locking screw (G).
Remove second locking screw (G) and spot-drill the console according toFig.X. Reinsert and tighten the locking screw (G).
Remove first locking screw (G) and spot-drill the console according toFig.X. Reinsert and tighten the locking screw (G).
Locking screws (G) M5Hex head wrench 2,5 mm
1.5 Central Pole Mounting
Prepare the post with its foundation, taking in account the wind loadstressing. All electrical lines are to be fed through the inside of thepost.
Prior to any installation works the mains power has to bedisconnected!
Feed the cables through the post, slide the clock onto the post andadjust the clock face to desired angle. At least one locking screwhas to be used on the pole.
Pole diameter: max. 72 mm.
4ø
G
Fig. X
G
51ø mm min.
72ø mm max.
147
pole
© MOBATIME 5 / 20 800429.06
1.6 Open Clock
Prior to any work inside the clock, all electrical lines have to be switched off!
Remove all four screws on one clock side from the case ring. Pull case ring with glass cover and dial from theclock’s cabinet. Disconnect electrical terminals from clock movement.
To avoid any damage to the fluorescent tube, it is recommended to remove the fluorescent tube during theinstallation work.
Self-setting movements: Do not touch the hands!
1.7 Close Clock
Reconnect the electrical terminals to the movement. Put case ring with glass cover and dial onto the clock’scabinet, press lightly and reinsert the four screws.
Be aware of the cable’s position inside the clock as they may shade the illuminated dial.
1.8 CleaningClean Glass with a humid cloth. Do not use solvent, evaporating or organic detergent.
2. Electrical connections
2.1 Mains power supplyThe mains power supply for illumination and clock movement may only be connected from a licensedelectrician.
Provide the same phase with only one fuse for time and clock supply.
The timing switch for the illumination has to be installed with respect to the constructional situation. Thepower supply for the movements has to be permanent.For cable entry of the line for minute impulse resp. the DCF-77 – radio receiver a second membrane rubberbushing is prepared.Connections and plug-in connections see mounting plates (pages 10-18).
Warning:Disconnect mains 230V/50Hz BEFORE start working at clock inside!
Detail of mains connection on mounting plates:
450
mA
230
V/5
0H
z
NP
2P
1 - Mains connection for clock movements- Mains connection for illumination- Neutral wire
© MOBATIME 6 / 20 800429.06
Electrical connections:
- Autonomous clocks with quartz controlled movement (QU)
ML(B).QU.50.3xx.xx, ML(B).QU.60.3xx.xx, ML(B).QU.80.3xx.xx
see mounting plate with clock movement QU 192 page 11/20
- Autonomous clocks synchronized with DCF 77 timecode (FWU)
ML(B).FWU.50.3xx.xx, ML(B).FWU.60.3xx.xx, ML(B).FWU.80.3xx.xx
see mounting plate with clock movement FU 192 page 11/20
- Autonomous clocks synchronized from GPS (GU)
ML(B).GU.50.3xx.xx, ML(B).GU.60.3xx.xx, ML(B).GU.80.3xx.xx
see mounting plate with clock movement GU 192 page 11/20
- Slave clocks for minute pulses (A, F)
ML(B).A.50.3xx.xx, ML(B).A.60.3xx.xx, ML(B).A.80.3xx.xx
see mounting plate with clock movement NU 90t page 13/20
ML(B).F.50.3xx.xx, ML(B).F.60.3xx.xx, ML(B).F.80.3xx.xx
see mounting plate with clock movement NU 90t/SYN page 13/20
- Slave clocks for MOBALine without mains connection (SAM, SFM)
ML(B).SAM.50.3xx.xx, ML(B).SAM.60.3xx.xx, ML(B).SAM.80.3xx.xx
see mounting plate with clock movement MLU 190t page 14/20
ML(B).SFM.50.3xx.xx, ML(B).SFM.60.3xx.xx, ML(B).SFM.80.3xx.xx
see mounting plate with clock movement MLU 190t S 48 page 14/20
- Slave clocks for MOBALine with mains connection (SAM230, SFM230)
ML(B).SAM230.50.3xx.xx, ML(B).SAM230.60.3xx.xx, ML(B).SAM230.80.3xx.xx
see mounting plate with clock movement MLU 190t 230 page 14/20
ML(B).SFM230.50.3xx.xx, ML(B).SFM230.60.3xx.xx, ML(B).SFM230.80.3xx.xx
see mounting plate with clock movement MLU 190t S 230 page 14/20
- Slave clocks for DCF 77 timecode with mains connection (SAA, SFA)
ML(B).SAA.50.3xx.xx, ML(B).SAA.60.3xx.xx, ML(B).SAA.80.3xx.xx
see mounting plate with clock movement BU 190t 230 page 15/20
ML(B).SFA.50.3xx.xx, ML(B).SFA.60.3xx.xx, ML(B).SFA.80.3xx.xx
see mounting plate with clock movement BU 190t S 230 page 15/20
- Slave clocks for audio frequency clock movement and mains connection (SAT, SFT)
ML(B).SAT.50.3xx.xx, ML(B).SAT.60.3xx.xx, ML(B).SAT.80.3xx.xx
see mounting plate with clock movement ATBU 190t 230 page 15/20
ML(B).SFT.50.3xx.xx, ML(B).SFT.60.3xx.xx, ML(B).SFT.80.3xx.xx
see mounting plate with clock movement ITBU 190t S 230 page 15/20
- Slave clocks for serial telegram and mains connection (SAS, SFS)
ML(B).SAS.50.3xx.xx, ML(B).SAS.60.3xx.xx, ML(B).SAS.80.3xx.xx
see mounting plate with clock movement SU 190t 230 page 16/20
ML(B).SFS.50.3xx.xx, ML(B).SFS.60.3xx.xx, ML(B).SFS.80.3xx.xx
see mounting plate with clock movement SU 190t S 230 page 16/20
- Slave clocks for NTP synchronisation over NCI (SAN2, SFN2)
ML(B).SAN2.50.3xx.xx, ML(B).SAN2.60.3xx.xx, ML(B).SAN2.80.3xx.xx
see mounting plate with clock movement MLU 190t Seite 17/20
ML(B).SFN2.50.3xx.xx, ML(B).SFN2.60.3xx.xx, ML(B).SFN2.80.3xx.xx
see mounting plate with clock movement MLU 190t S 48 Seite 17/20
- Slave clocks for NTP synchronisation (SAN3, SFN3)
ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx
see mounting plate with clock movement NBU 190t 24/PoE Seite 18/20
ML(B).SFN3.50.3xx.xx, ML(B).SFN3.60.3xx.xx, ML(B).SFN3.80.3xx.xx
see mounting plate with clock movement NBU 190t S 24/PoE Seite 18/20
© MOBATIME 7 / 20 800429.06
2.2 Internal connections
The internal wiring is made in factory. It’s important not to modify the internal wiring,
2.3 Autonomous quartz clocks (QU)
The movement is driven by battery.
Battery life with lithium battery (250394): 6 – 7 years.
2.4 Autonomous clocks with external DCF 77 radio receiver (FWU)
The DCF 77 radio receiver AD 192 is as normal fitted on the movement and is used for indoor mounting only.For clocks with illumination, the external radio receiver AD 192.5 has to be used.If the reception quality is bad, it’s recommended to use the external radio receiver too.The radio receiver AD 192.5 is delivered with protection IP 54 and 5m cable for outdoor mounting.
The radio controlled movement FU 192 is driven with two mono cells (only for indoor use), resp. a Lithiumbattery or an external power supply, protected against power-fail by an accumulator.
To check the reception quality, press the reset button on backside of the movement as long as the clock isopen. This activates the radio reception and the LED on the movement should flicker once a second. If not,change the direction of the antenna).
METROLINE clocks with radio-controlled movements FU 192 are delivered with a special, detailed instructionmanual (BE-800163).
Battery life with lithium battery (250394): 6 – 7 years.
FU 192t 200206
250394battery lithium
BU 192t 200204
battery lithium 250394
AD 192.5 200897
COM 192 200045
© MOBATIME 8 / 20 800429.06
2.5 Autonomous clocks with external GPS-receiver, battery or mains powered (GU)
The antenna must be mounted outdoors in horizontal position.
METROLINE–clocks with autonomous radio controlled movements GU 192 aredelivered with a special, detailed instruction manual (BE – 800 304).
Operation time with lithium battery (250394): > 5 years.
2.6 Slave clocks for minute impulses (A, F)
NU90t, NU 90t/SYN
- Operating voltage switch (C) on back side of movement
The operating voltage is factory set to 24 VDC.
If other voltage required, set DIP – switch accordingto diagram on backside of movement.
SMB5m
GPS-Antenne
OUT
Batterie Lithium 250394
GU 192t
© MOBATIME 9 / 20 800429.06
2.7 Slave clocks (SAx, SFx)
applicabledocuments
- Slave clocks for DCF 77 reception and mains power supply (SAA, SFA)
ML(B).SAA.50.3xx.xx, ML(B).SAA.60.3xx.xx, ML(B).SAA.80.3xx.xx
manual with movement BU 190t 230 BE – 800 603
ML(B).SFA.50.3xx.xx, ML(B).SFA.60.3xx.xx, ML(B).SFA.80.3xx.xx
manual with movement BU 190t S 230 BE – 800 602
- Slave clocks for MOBALine and mains power supply (SAM230, SFM230)
ML(B).SAM230.50.3xx.xx, ML(B).SAM230.60.3xx.xx, ML(B).SAM230.80.3xx.xx
manual with movement MLU 190t 230 BE – 800 622
ML(B).SFM230.50.3xx.xx, ML(B).SFM230.60.3xx.xx, ML(B).SFM230.80.3xx.xx
manual with movement MLU 190t S 230 BE – 800 565
- Slave clocks for MOBALine without mains power supply (SAM, SFM)
ML(B).SAM.50.3xx.xx, ML(B).SAM.60.3xx.xx, ML(B).SAM.80.3xx.xx
manual with movement MLU 190t BE – 800 642
ML(B).SFM.50.3xx.xx, ML(B).SFM.60.3xx.xx, ML(B).SFM.80.3xx.xx
manual with movement MLU 190t S 48 BE – 800 621
- Slave clocks for audio frequency time code and mains power supply (SAT, SFT)
ML(B).SAT.50.3xx.xx, ML(B).SAT.60.3xx.xx, ML(B).SAT.80.3xx.xx
manual with movement ATBU 190t 230 BE – 800 390
ML(B).SFT.50.3xx.xx, ML(B).SFT.60.3xx.xx, ML(B).SFT.80.3xx.xx
manual with movement ITBU 190t S 230 BE – 800 390
- Slave clocks for serial synchronization and mains connection (SAS, SFS)
ML(B).SAS.50.3xx.xx, ML(B).SAS.60.3xx.xx, ML(B).SAS.80.3xx.xx
manual with movement SU 190t 230 BE – 800 623
ML(B).SFS.50.3xx.xx, ML(B).SFS.60.3xx.xx, ML(B).SFS.80.3xx.xx
manual with movement SU 190t S 230 BE – 800 624
- Slave clocks for synchronization via NTP protocol (SAN3, SFN3)
ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx
manual with movement NBU 190t 230 BE – 800 xxx
ML(B).SFN3.50.3xx.xx, ML(B).SFN3.60.3xx.xx, ML(B).SFN3.80.3xx.xx
manual with movement NBU 190t S 230 BE – 800 540
© MOBATIME 10 / 20 800429.06
3 Set clock to correct time
3.1 Pulse controlled slave clocks (NU 90t / NU 90t SYN)Push button (A) and turn, until hour and minute – hands shows desired time.Never turn the second hand manually, as this will damage the movement. Also, theminute hand may only be turned in clockwise direction.Hand will be set with each minute pulse!If there would be a difference of 1 min. betweenmaster clock and secondary clock time, movethe plug (B) to the opposite pair of pins toreverse polarity and set minute hand 2 minutesforwards.
3.2 Self-setting movements
BU 190t xxx, MLU 190 xxx, xTBU 190t xxx, SU 190t xxx, GU 192, FU 192
No time settings needed, clock will set up automatically to current time.Movements are set by factory to standard run mode (DIP switch for 12:00 position in OFF position).If a clock does not run to correct time, set 12:00 position DIP switch to ON and check, if the hands are stoppingat 12:00 position exactly (if not, remove the clock hands and fix them exactly at 12:00 position).Correct time and guaranteed time and power reserve, as well as precision of the clock can only be guaranteedafter 2-3 days of working.
For further information read the documentation of respective movements (see 2.7).
4 Replacement of lamp and starterExcept from the replacement of lamp and starter, the clock is maintenance-free.
4.1 Opening clockRemove all four screws on one clock side from the case ring. Pull case ring with glass cover and dial from theclock’s cabinet. Disconnect electrical terminals from clock movement.
To avoid any damage to the fluorescent tube, it is recommended to remove the fluorescent tube during theinstallation work.
4.2 Replacement of lamp
ML(B).xxx.50... SYLVANIA CIRCLINE, 305 mm , FC 32W/154, daylight
ML(B).xxx.60/80 SYLVANIA CIRCLINE, 413 mm , FC 40W/154, daylightor OSRAM ring shape LUMILUX, cool white L40/21-840C
4.3 Replacement of starterSYLVANIA FS 11 or OSRAM ST 111 (4-80 W)
4.4 Replacement of ballastTRIDONIC.ATCO: EC 36 LC501 K, class EEI = B2
4.5 Close clockSee chapter 1.7.
4.6 CleaningSee chapter 1.8.
5 Valid documentsMovements series 190t see chapter 2.7Movement NU 90t/SYN BE-800 143Movement NU 90t BE-800 142DCF – receiver DCF 450 TE-800 116
© MOBATIME 11 / 20 800429.06
6 Connection diagramsOnly mounting plates for slave clock models with illumination are shown.
6.1 Battery-driven autonomous clocks (QU, FWU, GU)Electrical connections QU 192t
FWU 192tGU 192t
Order-No. ML(B).QU.xxML(B).FWU.xxML(B).GU.xx
with optional mains power supply (201670):
bl
bl
connectionring shape
connectionprotection earth
12
We
rk1
We
rk2
P1
P1
N
starter
ballast250 712
P1: Power supply movement (not needed)P2: Power supply illuminationN: Neutral wire
bl
bl
AnschlussRingröhre
AnschlussSchutzerde
12
We
rk1
We
rk2
P1
P1
N
movement 1-+
movement 2-+
starter
ballast250 712
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
© MOBATIME 12 / 20 800429.06
Cascade:O
UT
INO
UT
IN
OU
TIN
OU
TIN
OU
TIN
Cascading means that a number of movements will be connected inseries.Up to three slave movements BU 192 can be connected to onemaster movement.As master movement the following type can be used:
FU 192 QU 192 BU 192 mit serieller Synchronisation (with IF 494)
The cascading is done by means of a cascade cable COM 192(length 1m), enabling to synchronize 4 movements with only onereference signal. After starting-up the time synchronization for allmovements will follow in a few seconds only. Should the time for themaster movement change during the normal operation, the timetake-over for each connected movement will take about 2 minutes,which means totally about 8 minutes. This is also valid for thedaylight saving time change.
© MOBATIME 13 / 20 800429.06
bl
bl
connectionring shape
connectionprotection earth
12
We
rk1
We
rk2
P1
P1
N
minute pulses
ballast250 712
starter
slave clockpulses
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
Supply 230V movement 2
Supply 230V movement 1
6.2 Slave clocks for minute pulses without synchronous seconds (A)Electrical connections NU 90t
Order – No. MLB.A.xx.3xx.xx
6.3 Slave clocks for minute pulses with synchronous seconds (F)Electrical connections NU 90t SYN
Order – No MLB.F.xx.3xx.xx
12
Werk 2
}
Werk 1 Minutenimpulse
Minutenimpulse
Minutenimpulse
bl
bl
connectionring shape
connectionprotection earth
12
We
rk1
We
rk2
P1
P1
N
minute pulses
starter
ballast250 712
slave clockpulses
P1: Power supply movement (not needed)P2: Power supply illuminationN: Neutral wire
12 }
move-ment 2
minute pulses
minute pulses
minute pulses
move-ment 1
© MOBATIME 14 / 20 800429.06
bl
bl
12
We
rk1
We
rk2
P1
P1
N
MOBALine
starter
slave clockpulses
ballast250 712
connectionprotection earth
connectionring shape
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
Supply 230V movement 2
Supply 230V movement 1
6.4 Slave clocks with MOBALine (SAM, SFM)Electrical connections MLU 190t
MLU 190t S 48
Order – No. MLB.SAM.xx.3xx.xxMLB.SFM.xx.3xx.xx
6.5 Slave clocks with MOBALine (SAM230, SFM230)Electrical connections MLU 190t 230
MLU 190t S 230
Order – No. MLB.SAM230.xxMLB.SFM230.xx
12 }
MOBALine
move-ment 2
MOBALine
power supply 48V=(MLU 190t S 48 only)
move-ment 1
MOBALine
power supply 48V=(MLU 190t S 48 only)
bl
bl
connectionring shape
connectionprotection earth
12
We
rk1
We
rk2
P1
P1
N
ballast250 712
starter
slave clockpulses
MOBAline
P1: Power supply movement (not needed)P2: Power supply illuminationN: Neutral wire
12
move-ment 2
MOBALine
}
move-ment 1
MOBALine
MOBALine
© MOBATIME 15 / 20 800429.06
Vor
scha
ltger
ät
2
We
rk1
We
rk2
450
mA
230
V/5
0H
z
1
bl
bl
NP
2P
1
we +-
+-
DCF signal
slave clockpulses
ballast250 712
connectionprotection earth
connectionring shape
power supply 230V movement 2
power supply 230V movement 1
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
bl
bl
12
We
rk1
We
rk2
P1
P1
N
Timecode
starter
power supply 230V movement 2
power supply 230V movement 1
connectionprotection earth
connectionring shape
slave clocktime code
ballast250 712
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
6.6 Slave clocks for DCF- 77 radio reception (SAA, SFA)
Electrical connections BU 190t 230BU 190t S 230
Order – No. MLB.SAA.xx.3xx.xxMLB.SFA.xx.3xx.xx
6.7 Slave clocks for serial telegram synchronization (SAT, SFT)Electrical connections ATBU 190t 230
ATBU 190t S 230
Order – No. MLB.SAS.xx.3xx.xxMLB.SFS.xx.3xx.xx
12
+- move-
ment 1DCF
DCF-receiver
+- move-
ment 2 DCF
Optoc.
+
-
12
move-ment 1 time code
}
move-ment 2 time code
audio frequencytime code
ATBU: IRIG-B, AFNOR,DCF-FSK - time code
ITBU: minute pulses,IRIG-B, AFNOR,DCF-FSK - time code
© MOBATIME 16 / 20 800429.06
6.8 Slave clocks for synchronization over RS-485 (SAS, SFS)Electrical connections SU 190t 230
SU 190t S 230
Order – No. MLB.SAS.xx.3xx.xxMLB.SFS.xx.3xx.xx
internal wiring type SU 190t (S) 230 (illumination control)
Option SIC
230
V/5
0H
z4
50
mA
4 3 1
Werk
2W
erk
1
2
Vo
rscha
ltg.
NP
2P
1
Net Master Clock NMC
120R
SU 190(t) S 230(230V50/60 Hz)
12
34
56
78
ON
Addr. 16Addr. 8Addr. 4
Addr. 2Addr. 1
NoStopContinuous
12:00 Position
RS 485DC Input
SwitchOutput
230V50/60 Hz
230 V ±10%; 50-60 Hz; 10 mA
SU 190 S 230 A/N: 202291
P/N: 03959665 001
SensorInput
Addr. 0
Addr. 0Addr. 0Addr. 0
Addr. 0NoModeWobblingOn Time
SU 190(t) S 230(230V50/60 Hz)
12
34
56
78
ON
Addr. 16Addr. 8Addr. 4
Addr. 2Addr. 1
NoStopContinuous
12:00 Position
RS 485DC Input
SwitchOutput
230V50/60 Hz
230 V ±10%; 50-60 Hz; 10 mA
SU 190 S 230 A/N: 202291
P/N: 03959665 001
SensorInput
Addr. 0
Addr. 0Addr. 0Addr. 0Addr. 0
NoModeWobblingOn Time
3
42
1
starter
connectionprotection earth
connectionring shape
ballast250 712
Detail 1
power supply 230V movement 2
power supply 230V movement 1
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
SU 190t (S) 230(230V50/60 Hz)
12
34
56
78
ON
Addr. 16Addr.8Addr.4
Addr.2Addr.1
No StopContinuous
12:00 Position
RS 485DC Input
Swi tchOutput
230 V50/60 Hz
230 V ±10%; 50-60 Hz; 10 mA
SU 190 S 230 A/N: 202291
P/N: 03959665 001
SensorInput
Addr. 0Addr. 0Addr. 0Addr. 0Addr. 0
No ModeWobblingOn Time
PN
230V}
202517.00
450
mA
230
V/5
0H
zNP
2P
1
we
we
230
V/5
0H
z45
0m
A
4 3 1
Werk
2W
erk
1
2
Vors
ch
altg.
bl
blNP
2P
1 ballast
SU 190t (S) 230
12
34
56
78
ON
Addr. 16Addr.8
Addr.4Addr.2Addr.1
No StopContinuous
12:00Position
RS 485DC Input
SwitchOutput
230 V50/60 Hz
230 V ±10%; 50-60 Hz; 10 mA
SU 190 S 230 A/N: 202291
P/N: 03959665 001
SensorInput
Addr. 0Addr. 0Addr. 0
Addr. 0Addr. 0
No ModeWobblingOn Time
power supply 230V movement 2
power supply 230V movement 1
P1
P2
N
Perpetually230VAC/50Hz
Detail 2 for illuminationcontrol from NMC via RS 485
P1
P2
N
Important!230VAC/50Hz
from same fuse
Detail 2 for externalillumination control
Switched supplyfor illumination
Perpetually supplyfor movements
Detail 2
SensorIN
SwitchOUT
+ -
Detail 3
+-
Detail 3
W1{
{
Detail 1Connection ofRS 485/422signal
1
2
3
4
W2
GND
A
B
DC+ *
* DC supply only needed, if movementsaren't supplied by mains.
© MOBATIME 17 / 20 800429.06
6.9 Slave clocks for NTP-Synchronization over NCI
Electrical connections MLU 190tMLU 190t S 48
Order – No. ML(B).SAN2.xx.3xx.xxML(B).SFN2.xx.3xx.xx
P1
P2
N
230V/50H
z45
0mA
slave clocksMOBALine
connectinring shape
NCI
power supply MLU 190t S 48
ethernetPoE
ballast250 712
connectionprotection earth
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
movement 2 MOBALine
power supply 48V=(only MLU 190t S 48)
movement 1 MOBALine
power supply 48V=(only MLU 190t S 48)
NC
I
LAN (PoE)
© MOBATIME 18 / 20 800429.06
6.10 Slave clocks for NTP-SynchronizationElectrical connections NBU 190t 24/PoE
NBU 190t S 24/PoE
Order – No. ML(B).SAN3.xx.3xx.xxML(B).SFN3.xx.3xx.xx
Movements ML(B):
Metroline without illumination (ML): no mounting plate needed, supply and control over LAN-cable(PoE).
Metroline with illumination (MLB): mounting plate needed, to supply the illumination.
Ethernet LAN 10/100 MbpsPower over Ethernet PoE
Master Slave 1
bl
bl
12
We
rk1
We
rk2
P1
P1
N
ballast250 712
starter
connectionring shape
connectionprotection earth
P1: Power supply movementP2: Power supply illuminationN: Neutral wire
© MOBATIME 19 / 20 800429.06
© MOBATIME TE-800429.06
BÜRK MOBATIME GmbHPostfach 3760 D-78026 VS-Schwenningen
Steinkirchring 46 D-78056 VS-SchwenningenTelefon (07720) 8535 - 0 Telefax (07720) 8535 - 11
Internet: http://www.buerk-mobatime.de E-Mail: [email protected]
HEADQUARTERMOSER-BAER AG
Spitalstrasse 7 CH-3454 SumiswaldTel. +41 34 432 46 46 Fax. +41 34 432 46 99
[email protected] www.mobatime.com
SALES WORLDWIDEMOSER-BAER SA – EXPORT DIVISION
19 chemin du Champ-des-Filles CH-1228 Plan-les-Ouates/GETel. +41 22 884 96 11 Fax. +41 22 884 96 [email protected] www.mobatime.com
SALES SWITZERLANDMOBATIME SWISS AG
Stettbachstrasse 5 CH-8600 DübendorfTel. +41 44 802 75 75 Fax +41 44 802 75 65
[email protected] www.mobatime.ch
MOBATIME SWISS SAEn Budron H 20 CH-1052 Le Mont-sur-Lausanne
Tél. +41 21 654 33 50 Fax +41 21 654 33 [email protected] www.mobatime.ch