© MOBATIME TE-800429.06 Installation instructions METROLINE- industrial clocks, double-sided, round Before installation of the clock please read the manual carefully. References to the Instruction Manual 1. The information in this Instruction Manual can be changed at any time without previous notice. 2. This Instruction Manual has been composed with utmost care, in order to explain all details in respect of the operation of the product. Should you, nevertheless, have questions or discover errors in this Manual, please contact us. 3. We do not answer for direct or indirect damages, which could occur, when using this Manual 4. Please read the instructions carefully and start the setting-up of the product, only once you have correctly understood all information for the installation and of the operation. 5. The installation must only be carried out by skilled staff. 6. It is prohibited to reproduce, to store in a computer system or to transfer this publication in a way or another, even part of it. The copyright remains with all the rights with MOSER-BAER AG – CH 3454 Sumiswald / SWITZERLAND.

Transcript of TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation...

Page 1: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME TE-800429.06

Installation instructions

METROLINE- industrial clocks, double-sided, round

Before installation of the clock please read the manual carefully.

References to the Instruction Manual

1. The information in this Instruction Manual can be changed at any time without previousnotice.

2. This Instruction Manual has been composed with utmost care, in order to explain all details inrespect of the operation of the product. Should you, nevertheless, have questions or discovererrors in this Manual, please contact us.

3. We do not answer for direct or indirect damages, which could occur, when using this Manual

4. Please read the instructions carefully and start the setting-up of the product, only once youhave correctly understood all information for the installation and of the operation.

5. The installation must only be carried out by skilled staff.

6. It is prohibited to reproduce, to store in a computer system or to transfer this publication in away or another, even part of it. The copyright remains with all the rights with MOSER-BAERAG – CH 3454 Sumiswald / SWITZERLAND.

Page 2: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 2 / 20 800429.06

List of contentsSeite

Mounting guidelines..............................................................................................................................................31.1 Fastening "DA" "WA" "S" und "ZM" ..........................................................................................................31.2 Building Department / Authority Permit ....................................................................................................31.3 Wall Mounting...........................................................................................................................................41.4 Ceiling Mounting.......................................................................................................................................41.5 Central Pole Mounting ..............................................................................................................................41.6 Open Clock...............................................................................................................................................51.7 Close Clock ..............................................................................................................................................51.8 Cleaning ...................................................................................................................................................5

2. Electrical connections....................................................................................................................................52.1 Mains power supply..................................................................................................................................52.2 Internal connections .................................................................................................................................72.3 Autonomous quartz clocks (QU) ..............................................................................................................72.4 Autonomous clocks with external DCF 77 radio receiver (FWU).............................................................72.5 Autonomous clocks with external GPS-receiver, battery or mains powered (GU)...................................82.6 Slave clocks for minute impulses (A, F) ...................................................................................................82.7 Slave clocks (SAx, SFx) ...........................................................................................................................9

3 Set clock to correct time..............................................................................................................................103.1 Pulse controlled slave clocks (NU 90t / NU 90t SYN) ............................................................................103.2 Self-setting movements..........................................................................................................................10

4 Replacement of lamp and starter................................................................................................................104.1 Opening clock.........................................................................................................................................104.2 Replacement of lamp .............................................................................................................................104.3 Replacement of starter ...........................................................................................................................104.4 Replacement of ballast ...........................................................................................................................104.5 Close clock .............................................................................................................................................104.6 Cleaning .................................................................................................................................................10

5 Valid documents...........................................................................................................................................10

6 Connection diagrams...................................................................................................................................116.1 Battery-driven autonomous clocks (QU, FWU, GU)...............................................................................116.2 Slave clocks for minute pulses without synchronous seconds (A) .........................................................136.3 Slave clocks for minute pulses with synchronous seconds (F) ..............................................................136.4 Slave clocks with MOBALine (SAM, SFM) .............................................................................................146.5 Slave clocks with MOBALine (SAM230, SFM230) .................................................................................146.6 Slave clocks for DCF- 77 radio reception (SAA, SFA) ...........................................................................156.7 Slave clocks for serial telegram synchronization (SAT, SFT) ................................................................156.8 Slave clocks for synchronization over RS-485 (SAS, SFS)....................................................................166.9 Slave cloks for NTP-Synchronization over NCI ......................................................................................176.10 Slave cloks for NTP-Synchronization .....................................................................................................18

Page 3: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 3 / 20 800429.06

Mounting guidelines

1.1 Fastening "DA" "WA" "S" und "ZM"

Nominal- without illumination

types

with illumination

types

2-seitig 50 cm ML.xxx.50.3xx.xx MLB.xxx.50.3xx.xx

2-seitig 60 cm ML.xxx.60.3xx.xx MLB.xxx.60.3xx.xx

2-seitig 80 cm ML.xxx.80.3xx.xx MLB.xxx.80.3xx.xx

160,5

23

152

o 50

A

239

152-220

o13

90

126

150

186

cable entry Ø 40mm

"DA"

L

"DA"

"WA"

"ZM"

"S"

1.2 Building Department / Authority Permit

If necessary a building department / authority permit should be requested before mounting.

dial- A [mm]50 53460 63480 834

Option “DA“:L [mm] 500 / 600 / 800

Page 4: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 4 / 20 800429.06

1.3 Wall Mounting

All electrical lines are to be fed through the console (cableentry 40 mm).Prior to any installation works the mains power has tobe disconnected!

Set four bolts or plugs for screws according to the mountingsketch of figure in chapter 1. Feed the cables through theconsole, slide the clock onto the console and adjust the clockface to a vertical position.

Tighten both locking screws (G).

Locking screws (G) M5Hex head wrench 2,5 mm

1.4 Ceiling Mounting

All electrical lines are to be fed through the console (cable entry 40 mm).

Prior to any installation works the mains power has to bedisconnected!

Set four bolts or plugs for screws according to the mounting sketch offigure in chapter 1. Feed the cables through the console, slide the clockonto the console and adjust the clock face to desired angle.

Tighten first locking screw (G).

Remove second locking screw (G) and spot-drill the console according toFig.X. Reinsert and tighten the locking screw (G).

Remove first locking screw (G) and spot-drill the console according toFig.X. Reinsert and tighten the locking screw (G).

Locking screws (G) M5Hex head wrench 2,5 mm

1.5 Central Pole Mounting

Prepare the post with its foundation, taking in account the wind loadstressing. All electrical lines are to be fed through the inside of thepost.

Prior to any installation works the mains power has to bedisconnected!

Feed the cables through the post, slide the clock onto the post andadjust the clock face to desired angle. At least one locking screwhas to be used on the pole.

Pole diameter: max. 72 mm.

G

Fig. X

G

51ø mm min.

72ø mm max.

147

pole

Page 5: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 5 / 20 800429.06

1.6 Open Clock

Prior to any work inside the clock, all electrical lines have to be switched off!

Remove all four screws on one clock side from the case ring. Pull case ring with glass cover and dial from theclock’s cabinet. Disconnect electrical terminals from clock movement.

To avoid any damage to the fluorescent tube, it is recommended to remove the fluorescent tube during theinstallation work.

Self-setting movements: Do not touch the hands!

1.7 Close Clock

Reconnect the electrical terminals to the movement. Put case ring with glass cover and dial onto the clock’scabinet, press lightly and reinsert the four screws.

Be aware of the cable’s position inside the clock as they may shade the illuminated dial.

1.8 CleaningClean Glass with a humid cloth. Do not use solvent, evaporating or organic detergent.

2. Electrical connections

2.1 Mains power supplyThe mains power supply for illumination and clock movement may only be connected from a licensedelectrician.

Provide the same phase with only one fuse for time and clock supply.

The timing switch for the illumination has to be installed with respect to the constructional situation. Thepower supply for the movements has to be permanent.For cable entry of the line for minute impulse resp. the DCF-77 – radio receiver a second membrane rubberbushing is prepared.Connections and plug-in connections see mounting plates (pages 10-18).

Warning:Disconnect mains 230V/50Hz BEFORE start working at clock inside!

Detail of mains connection on mounting plates:

450

mA

230

V/5

0H

z

NP

2P

1 - Mains connection for clock movements- Mains connection for illumination- Neutral wire

Page 6: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 6 / 20 800429.06

Electrical connections:

- Autonomous clocks with quartz controlled movement (QU)

ML(B).QU.50.3xx.xx, ML(B).QU.60.3xx.xx, ML(B).QU.80.3xx.xx

see mounting plate with clock movement QU 192 page 11/20

- Autonomous clocks synchronized with DCF 77 timecode (FWU)

ML(B).FWU.50.3xx.xx, ML(B).FWU.60.3xx.xx, ML(B).FWU.80.3xx.xx

see mounting plate with clock movement FU 192 page 11/20

- Autonomous clocks synchronized from GPS (GU)

ML(B).GU.50.3xx.xx, ML(B).GU.60.3xx.xx, ML(B).GU.80.3xx.xx

see mounting plate with clock movement GU 192 page 11/20

- Slave clocks for minute pulses (A, F)

ML(B).A.50.3xx.xx, ML(B).A.60.3xx.xx, ML(B).A.80.3xx.xx

see mounting plate with clock movement NU 90t page 13/20

ML(B).F.50.3xx.xx, ML(B).F.60.3xx.xx, ML(B).F.80.3xx.xx

see mounting plate with clock movement NU 90t/SYN page 13/20

- Slave clocks for MOBALine without mains connection (SAM, SFM)

ML(B).SAM.50.3xx.xx, ML(B).SAM.60.3xx.xx, ML(B).SAM.80.3xx.xx

see mounting plate with clock movement MLU 190t page 14/20

ML(B).SFM.50.3xx.xx, ML(B).SFM.60.3xx.xx, ML(B).SFM.80.3xx.xx

see mounting plate with clock movement MLU 190t S 48 page 14/20

- Slave clocks for MOBALine with mains connection (SAM230, SFM230)

ML(B).SAM230.50.3xx.xx, ML(B).SAM230.60.3xx.xx, ML(B).SAM230.80.3xx.xx

see mounting plate with clock movement MLU 190t 230 page 14/20

ML(B).SFM230.50.3xx.xx, ML(B).SFM230.60.3xx.xx, ML(B).SFM230.80.3xx.xx

see mounting plate with clock movement MLU 190t S 230 page 14/20

- Slave clocks for DCF 77 timecode with mains connection (SAA, SFA)

ML(B).SAA.50.3xx.xx, ML(B).SAA.60.3xx.xx, ML(B).SAA.80.3xx.xx

see mounting plate with clock movement BU 190t 230 page 15/20

ML(B).SFA.50.3xx.xx, ML(B).SFA.60.3xx.xx, ML(B).SFA.80.3xx.xx

see mounting plate with clock movement BU 190t S 230 page 15/20

- Slave clocks for audio frequency clock movement and mains connection (SAT, SFT)

ML(B).SAT.50.3xx.xx, ML(B).SAT.60.3xx.xx, ML(B).SAT.80.3xx.xx

see mounting plate with clock movement ATBU 190t 230 page 15/20

ML(B).SFT.50.3xx.xx, ML(B).SFT.60.3xx.xx, ML(B).SFT.80.3xx.xx

see mounting plate with clock movement ITBU 190t S 230 page 15/20

- Slave clocks for serial telegram and mains connection (SAS, SFS)

ML(B).SAS.50.3xx.xx, ML(B).SAS.60.3xx.xx, ML(B).SAS.80.3xx.xx

see mounting plate with clock movement SU 190t 230 page 16/20

ML(B).SFS.50.3xx.xx, ML(B).SFS.60.3xx.xx, ML(B).SFS.80.3xx.xx

see mounting plate with clock movement SU 190t S 230 page 16/20

- Slave clocks for NTP synchronisation over NCI (SAN2, SFN2)

ML(B).SAN2.50.3xx.xx, ML(B).SAN2.60.3xx.xx, ML(B).SAN2.80.3xx.xx

see mounting plate with clock movement MLU 190t Seite 17/20

ML(B).SFN2.50.3xx.xx, ML(B).SFN2.60.3xx.xx, ML(B).SFN2.80.3xx.xx

see mounting plate with clock movement MLU 190t S 48 Seite 17/20

- Slave clocks for NTP synchronisation (SAN3, SFN3)

ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx

see mounting plate with clock movement NBU 190t 24/PoE Seite 18/20

ML(B).SFN3.50.3xx.xx, ML(B).SFN3.60.3xx.xx, ML(B).SFN3.80.3xx.xx

see mounting plate with clock movement NBU 190t S 24/PoE Seite 18/20

Page 7: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 7 / 20 800429.06

2.2 Internal connections

The internal wiring is made in factory. It’s important not to modify the internal wiring,

2.3 Autonomous quartz clocks (QU)

The movement is driven by battery.

Battery life with lithium battery (250394): 6 – 7 years.

2.4 Autonomous clocks with external DCF 77 radio receiver (FWU)

The DCF 77 radio receiver AD 192 is as normal fitted on the movement and is used for indoor mounting only.For clocks with illumination, the external radio receiver AD 192.5 has to be used.If the reception quality is bad, it’s recommended to use the external radio receiver too.The radio receiver AD 192.5 is delivered with protection IP 54 and 5m cable for outdoor mounting.

The radio controlled movement FU 192 is driven with two mono cells (only for indoor use), resp. a Lithiumbattery or an external power supply, protected against power-fail by an accumulator.

To check the reception quality, press the reset button on backside of the movement as long as the clock isopen. This activates the radio reception and the LED on the movement should flicker once a second. If not,change the direction of the antenna).

METROLINE clocks with radio-controlled movements FU 192 are delivered with a special, detailed instructionmanual (BE-800163).

Battery life with lithium battery (250394): 6 – 7 years.

FU 192t 200206

250394battery lithium

BU 192t 200204

battery lithium 250394

AD 192.5 200897

COM 192 200045

Page 8: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 8 / 20 800429.06

2.5 Autonomous clocks with external GPS-receiver, battery or mains powered (GU)

The antenna must be mounted outdoors in horizontal position.

METROLINE–clocks with autonomous radio controlled movements GU 192 aredelivered with a special, detailed instruction manual (BE – 800 304).

Operation time with lithium battery (250394): > 5 years.

2.6 Slave clocks for minute impulses (A, F)

NU90t, NU 90t/SYN

- Operating voltage switch (C) on back side of movement

The operating voltage is factory set to 24 VDC.

If other voltage required, set DIP – switch accordingto diagram on backside of movement.

SMB5m

GPS-Antenne

OUT

Batterie Lithium 250394

GU 192t

Page 9: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 9 / 20 800429.06

2.7 Slave clocks (SAx, SFx)

applicabledocuments

- Slave clocks for DCF 77 reception and mains power supply (SAA, SFA)

ML(B).SAA.50.3xx.xx, ML(B).SAA.60.3xx.xx, ML(B).SAA.80.3xx.xx

manual with movement BU 190t 230 BE – 800 603

ML(B).SFA.50.3xx.xx, ML(B).SFA.60.3xx.xx, ML(B).SFA.80.3xx.xx

manual with movement BU 190t S 230 BE – 800 602

- Slave clocks for MOBALine and mains power supply (SAM230, SFM230)

ML(B).SAM230.50.3xx.xx, ML(B).SAM230.60.3xx.xx, ML(B).SAM230.80.3xx.xx

manual with movement MLU 190t 230 BE – 800 622

ML(B).SFM230.50.3xx.xx, ML(B).SFM230.60.3xx.xx, ML(B).SFM230.80.3xx.xx

manual with movement MLU 190t S 230 BE – 800 565

- Slave clocks for MOBALine without mains power supply (SAM, SFM)

ML(B).SAM.50.3xx.xx, ML(B).SAM.60.3xx.xx, ML(B).SAM.80.3xx.xx

manual with movement MLU 190t BE – 800 642

ML(B).SFM.50.3xx.xx, ML(B).SFM.60.3xx.xx, ML(B).SFM.80.3xx.xx

manual with movement MLU 190t S 48 BE – 800 621

- Slave clocks for audio frequency time code and mains power supply (SAT, SFT)

ML(B).SAT.50.3xx.xx, ML(B).SAT.60.3xx.xx, ML(B).SAT.80.3xx.xx

manual with movement ATBU 190t 230 BE – 800 390

ML(B).SFT.50.3xx.xx, ML(B).SFT.60.3xx.xx, ML(B).SFT.80.3xx.xx

manual with movement ITBU 190t S 230 BE – 800 390

- Slave clocks for serial synchronization and mains connection (SAS, SFS)

ML(B).SAS.50.3xx.xx, ML(B).SAS.60.3xx.xx, ML(B).SAS.80.3xx.xx

manual with movement SU 190t 230 BE – 800 623

ML(B).SFS.50.3xx.xx, ML(B).SFS.60.3xx.xx, ML(B).SFS.80.3xx.xx

manual with movement SU 190t S 230 BE – 800 624

- Slave clocks for synchronization via NTP protocol (SAN3, SFN3)

ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx

manual with movement NBU 190t 230 BE – 800 xxx

ML(B).SFN3.50.3xx.xx, ML(B).SFN3.60.3xx.xx, ML(B).SFN3.80.3xx.xx

manual with movement NBU 190t S 230 BE – 800 540

Page 10: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 10 / 20 800429.06

3 Set clock to correct time

3.1 Pulse controlled slave clocks (NU 90t / NU 90t SYN)Push button (A) and turn, until hour and minute – hands shows desired time.Never turn the second hand manually, as this will damage the movement. Also, theminute hand may only be turned in clockwise direction.Hand will be set with each minute pulse!If there would be a difference of 1 min. betweenmaster clock and secondary clock time, movethe plug (B) to the opposite pair of pins toreverse polarity and set minute hand 2 minutesforwards.

3.2 Self-setting movements

BU 190t xxx, MLU 190 xxx, xTBU 190t xxx, SU 190t xxx, GU 192, FU 192

No time settings needed, clock will set up automatically to current time.Movements are set by factory to standard run mode (DIP switch for 12:00 position in OFF position).If a clock does not run to correct time, set 12:00 position DIP switch to ON and check, if the hands are stoppingat 12:00 position exactly (if not, remove the clock hands and fix them exactly at 12:00 position).Correct time and guaranteed time and power reserve, as well as precision of the clock can only be guaranteedafter 2-3 days of working.

For further information read the documentation of respective movements (see 2.7).

4 Replacement of lamp and starterExcept from the replacement of lamp and starter, the clock is maintenance-free.

4.1 Opening clockRemove all four screws on one clock side from the case ring. Pull case ring with glass cover and dial from theclock’s cabinet. Disconnect electrical terminals from clock movement.

To avoid any damage to the fluorescent tube, it is recommended to remove the fluorescent tube during theinstallation work.

4.2 Replacement of lamp

ML(B).xxx.50... SYLVANIA CIRCLINE, 305 mm , FC 32W/154, daylight

ML(B).xxx.60/80 SYLVANIA CIRCLINE, 413 mm , FC 40W/154, daylightor OSRAM ring shape LUMILUX, cool white L40/21-840C

4.3 Replacement of starterSYLVANIA FS 11 or OSRAM ST 111 (4-80 W)

4.4 Replacement of ballastTRIDONIC.ATCO: EC 36 LC501 K, class EEI = B2

4.5 Close clockSee chapter 1.7.

4.6 CleaningSee chapter 1.8.

5 Valid documentsMovements series 190t see chapter 2.7Movement NU 90t/SYN BE-800 143Movement NU 90t BE-800 142DCF – receiver DCF 450 TE-800 116

Page 11: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 11 / 20 800429.06

6 Connection diagramsOnly mounting plates for slave clock models with illumination are shown.

6.1 Battery-driven autonomous clocks (QU, FWU, GU)Electrical connections QU 192t

FWU 192tGU 192t

Order-No. ML(B).QU.xxML(B).FWU.xxML(B).GU.xx

with optional mains power supply (201670):

bl

bl

connectionring shape

connectionprotection earth

12

We

rk1

We

rk2

P1

P1

N

starter

ballast250 712

P1: Power supply movement (not needed)P2: Power supply illuminationN: Neutral wire

bl

bl

AnschlussRingröhre

AnschlussSchutzerde

12

We

rk1

We

rk2

P1

P1

N

movement 1-+

movement 2-+

starter

ballast250 712

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

Page 12: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 12 / 20 800429.06

Cascade:O

UT

INO

UT

IN

OU

TIN

OU

TIN

OU

TIN

Cascading means that a number of movements will be connected inseries.Up to three slave movements BU 192 can be connected to onemaster movement.As master movement the following type can be used:

FU 192 QU 192 BU 192 mit serieller Synchronisation (with IF 494)

The cascading is done by means of a cascade cable COM 192(length 1m), enabling to synchronize 4 movements with only onereference signal. After starting-up the time synchronization for allmovements will follow in a few seconds only. Should the time for themaster movement change during the normal operation, the timetake-over for each connected movement will take about 2 minutes,which means totally about 8 minutes. This is also valid for thedaylight saving time change.

Page 13: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 13 / 20 800429.06

bl

bl

connectionring shape

connectionprotection earth

12

We

rk1

We

rk2

P1

P1

N

minute pulses

ballast250 712

starter

slave clockpulses

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

Supply 230V movement 2

Supply 230V movement 1

6.2 Slave clocks for minute pulses without synchronous seconds (A)Electrical connections NU 90t

Order – No. MLB.A.xx.3xx.xx

6.3 Slave clocks for minute pulses with synchronous seconds (F)Electrical connections NU 90t SYN

Order – No MLB.F.xx.3xx.xx

12

Werk 2

}

Werk 1 Minutenimpulse

Minutenimpulse

Minutenimpulse

bl

bl

connectionring shape

connectionprotection earth

12

We

rk1

We

rk2

P1

P1

N

minute pulses

starter

ballast250 712

slave clockpulses

P1: Power supply movement (not needed)P2: Power supply illuminationN: Neutral wire

12 }

move-ment 2

minute pulses

minute pulses

minute pulses

move-ment 1

Page 14: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 14 / 20 800429.06

bl

bl

12

We

rk1

We

rk2

P1

P1

N

MOBALine

starter

slave clockpulses

ballast250 712

connectionprotection earth

connectionring shape

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

Supply 230V movement 2

Supply 230V movement 1

6.4 Slave clocks with MOBALine (SAM, SFM)Electrical connections MLU 190t

MLU 190t S 48

Order – No. MLB.SAM.xx.3xx.xxMLB.SFM.xx.3xx.xx

6.5 Slave clocks with MOBALine (SAM230, SFM230)Electrical connections MLU 190t 230

MLU 190t S 230

Order – No. MLB.SAM230.xxMLB.SFM230.xx

12 }

MOBALine

move-ment 2

MOBALine

power supply 48V=(MLU 190t S 48 only)

move-ment 1

MOBALine

power supply 48V=(MLU 190t S 48 only)

bl

bl

connectionring shape

connectionprotection earth

12

We

rk1

We

rk2

P1

P1

N

ballast250 712

starter

slave clockpulses

MOBAline

P1: Power supply movement (not needed)P2: Power supply illuminationN: Neutral wire

12

move-ment 2

MOBALine

}

move-ment 1

MOBALine

MOBALine

Page 15: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 15 / 20 800429.06

Vor

scha

ltger

ät

2

We

rk1

We

rk2

450

mA

230

V/5

0H

z

1

bl

bl

NP

2P

1

we +-

+-

DCF signal

slave clockpulses

ballast250 712

connectionprotection earth

connectionring shape

power supply 230V movement 2

power supply 230V movement 1

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

bl

bl

12

We

rk1

We

rk2

P1

P1

N

Timecode

starter

power supply 230V movement 2

power supply 230V movement 1

connectionprotection earth

connectionring shape

slave clocktime code

ballast250 712

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

6.6 Slave clocks for DCF- 77 radio reception (SAA, SFA)

Electrical connections BU 190t 230BU 190t S 230

Order – No. MLB.SAA.xx.3xx.xxMLB.SFA.xx.3xx.xx

6.7 Slave clocks for serial telegram synchronization (SAT, SFT)Electrical connections ATBU 190t 230

ATBU 190t S 230

Order – No. MLB.SAS.xx.3xx.xxMLB.SFS.xx.3xx.xx

12

+- move-

ment 1DCF

DCF-receiver

+- move-

ment 2 DCF

Optoc.

+

-

12

move-ment 1 time code

}

move-ment 2 time code

audio frequencytime code

ATBU: IRIG-B, AFNOR,DCF-FSK - time code

ITBU: minute pulses,IRIG-B, AFNOR,DCF-FSK - time code

Page 16: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 16 / 20 800429.06

6.8 Slave clocks for synchronization over RS-485 (SAS, SFS)Electrical connections SU 190t 230

SU 190t S 230

Order – No. MLB.SAS.xx.3xx.xxMLB.SFS.xx.3xx.xx

internal wiring type SU 190t (S) 230 (illumination control)

Option SIC

230

V/5

0H

z4

50

mA

4 3 1

Werk

2W

erk

1

2

Vo

rscha

ltg.

NP

2P

1

Net Master Clock NMC

120R

SU 190(t) S 230(230V50/60 Hz)

12

34

56

78

ON

Addr. 16Addr. 8Addr. 4

Addr. 2Addr. 1

NoStopContinuous

12:00 Position

RS 485DC Input

SwitchOutput

230V50/60 Hz

230 V ±10%; 50-60 Hz; 10 mA

SU 190 S 230 A/N: 202291

P/N: 03959665 001

SensorInput

Addr. 0

Addr. 0Addr. 0Addr. 0

Addr. 0NoModeWobblingOn Time

SU 190(t) S 230(230V50/60 Hz)

12

34

56

78

ON

Addr. 16Addr. 8Addr. 4

Addr. 2Addr. 1

NoStopContinuous

12:00 Position

RS 485DC Input

SwitchOutput

230V50/60 Hz

230 V ±10%; 50-60 Hz; 10 mA

SU 190 S 230 A/N: 202291

P/N: 03959665 001

SensorInput

Addr. 0

Addr. 0Addr. 0Addr. 0Addr. 0

NoModeWobblingOn Time

3

42

1

starter

connectionprotection earth

connectionring shape

ballast250 712

Detail 1

power supply 230V movement 2

power supply 230V movement 1

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

SU 190t (S) 230(230V50/60 Hz)

12

34

56

78

ON

Addr. 16Addr.8Addr.4

Addr.2Addr.1

No StopContinuous

12:00 Position

RS 485DC Input

Swi tchOutput

230 V50/60 Hz

230 V ±10%; 50-60 Hz; 10 mA

SU 190 S 230 A/N: 202291

P/N: 03959665 001

SensorInput

Addr. 0Addr. 0Addr. 0Addr. 0Addr. 0

No ModeWobblingOn Time

PN

230V}

202517.00

450

mA

230

V/5

0H

zNP

2P

1

we

we

230

V/5

0H

z45

0m

A

4 3 1

Werk

2W

erk

1

2

Vors

ch

altg.

bl

blNP

2P

1 ballast

SU 190t (S) 230

12

34

56

78

ON

Addr. 16Addr.8

Addr.4Addr.2Addr.1

No StopContinuous

12:00Position

RS 485DC Input

SwitchOutput

230 V50/60 Hz

230 V ±10%; 50-60 Hz; 10 mA

SU 190 S 230 A/N: 202291

P/N: 03959665 001

SensorInput

Addr. 0Addr. 0Addr. 0

Addr. 0Addr. 0

No ModeWobblingOn Time

power supply 230V movement 2

power supply 230V movement 1

P1

P2

N

Perpetually230VAC/50Hz

Detail 2 for illuminationcontrol from NMC via RS 485

P1

P2

N

Important!230VAC/50Hz

from same fuse

Detail 2 for externalillumination control

Switched supplyfor illumination

Perpetually supplyfor movements

Detail 2

SensorIN

SwitchOUT

+ -

Detail 3

+-

Detail 3

W1{

{

Detail 1Connection ofRS 485/422signal

1

2

3

4

W2

GND

A

B

DC+ *

* DC supply only needed, if movementsaren't supplied by mains.

Page 17: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 17 / 20 800429.06

6.9 Slave clocks for NTP-Synchronization over NCI

Electrical connections MLU 190tMLU 190t S 48

Order – No. ML(B).SAN2.xx.3xx.xxML(B).SFN2.xx.3xx.xx

P1

P2

N

230V/50H

z45

0mA

slave clocksMOBALine

connectinring shape

NCI

power supply MLU 190t S 48

ethernetPoE

ballast250 712

connectionprotection earth

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

movement 2 MOBALine

power supply 48V=(only MLU 190t S 48)

movement 1 MOBALine

power supply 48V=(only MLU 190t S 48)

NC

I

LAN (PoE)

Page 18: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 18 / 20 800429.06

6.10 Slave clocks for NTP-SynchronizationElectrical connections NBU 190t 24/PoE

NBU 190t S 24/PoE

Order – No. ML(B).SAN3.xx.3xx.xxML(B).SFN3.xx.3xx.xx

Movements ML(B):

Metroline without illumination (ML): no mounting plate needed, supply and control over LAN-cable(PoE).

Metroline with illumination (MLB): mounting plate needed, to supply the illumination.

Ethernet LAN 10/100 MbpsPower over Ethernet PoE

Master Slave 1

bl

bl

12

We

rk1

We

rk2

P1

P1

N

ballast250 712

starter

connectionring shape

connectionprotection earth

P1: Power supply movementP2: Power supply illuminationN: Neutral wire

Page 19: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME 19 / 20 800429.06

Page 20: TE-800429.06-Metroline-Installationsanleitung ML rund ... · - Slave clocks for NTP synchronisation (SAN3, SFN3) ML(B).SAN3.50.3xx.xx, ML(B).SAN3.60.3xx.xx, ML(B).SAN3.80.3xx.xx see

© MOBATIME TE-800429.06

BÜRK MOBATIME GmbHPostfach 3760 D-78026 VS-Schwenningen

Steinkirchring 46 D-78056 VS-SchwenningenTelefon (07720) 8535 - 0 Telefax (07720) 8535 - 11

Internet: http://www.buerk-mobatime.de E-Mail: [email protected]

HEADQUARTERMOSER-BAER AG

Spitalstrasse 7 CH-3454 SumiswaldTel. +41 34 432 46 46 Fax. +41 34 432 46 99

[email protected] www.mobatime.com

SALES WORLDWIDEMOSER-BAER SA – EXPORT DIVISION

19 chemin du Champ-des-Filles CH-1228 Plan-les-Ouates/GETel. +41 22 884 96 11 Fax. +41 22 884 96 [email protected] www.mobatime.com

SALES SWITZERLANDMOBATIME SWISS AG

Stettbachstrasse 5 CH-8600 DübendorfTel. +41 44 802 75 75 Fax +41 44 802 75 65

[email protected] www.mobatime.ch

MOBATIME SWISS SAEn Budron H 20 CH-1052 Le Mont-sur-Lausanne

Tél. +41 21 654 33 50 Fax +41 21 654 33 [email protected] www.mobatime.ch