Tap-Changer VUCGLB Balamurugan N Approved by …...Balamurugan N 2015-02-15 Modified by Take over...

2
This document is issued by means of a computerized syste The digitally stored original is ele ctronically approved approved document has a date entered in the `Approved'-f A manual signature is not required. The information contained in this document has to kept strictly confidential. Any unautorized use, reproduction, distribution or disclosure to third parties are strictly forbidden. ABB reservs all rights regarding Intellectual Property Rights. © Copyright 2013 ABB. All rights reserved. 6917 028-PA(A4)Rev1 255 27 30 50 D 470 111 205 C 740 710 220 220 98 6 519 A B 45 39 C/L Top flange 80 332 60 C/L Diverter switch 30 24x 15 E 289 110 C/L Tap selector INSULATION380 1050 SHORT VERSION b) LEVEL kV 650 380,650 750 750 1050 A1711 a)2011 a)1491 a)1791 a) Dimen- sions in mm B 1192 a)1492 a)972 a)1272 a) C 119 a)c) 119 a) 119 a)c) 119 a) D 240 c) 540 240 c) 540 Positions E 5-14 18 15-18 56 (2) 1ZSC004912-AAE No. Shts. Document no. 1 5-18 Pos A Sheet no. Order Revision 82 (1 Phase),E,T XXXX/450-600/C 2015-02-15 Swen Mattsson Language Used in product Approved by Tap-Changer VUCGLB 2015-02-15 Balamurugan N Take over department Modified by PPCO/TK 2015-02-09 Praveenkumar B Title Responsible department Prepared V-2,4..18 Same potential as the diverter switch terminal Shielding rings for insulation levels 650, 750 and 1050 only Only for insulation level 1050 kV Transformer flange Lower ring not for short version a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1) b) Short version means reduced switching capac Please refer to Technical Guide c) Not applicable for 380 kV Contact 10 at 5-10 pos. Contact 12 at 11-12 pos. Contact 14 at 13-14 pos. Contact 16 at 15-16 pos. Contact 18 at 17-18 pos. Only for insulation level 650, 750 and 1050 kV H-1,3..17

Transcript of Tap-Changer VUCGLB Balamurugan N Approved by …...Balamurugan N 2015-02-15 Modified by Take over...

Page 1: Tap-Changer VUCGLB Balamurugan N Approved by …...Balamurugan N 2015-02-15 Modified by Take over department Praveenkumar B 2015-02-09 PPCO/TK Prepared Responsible department Title

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2013 ABB. All rights reserved.

6917 028-PA(A4)Rev1

255

27

30

50

D

470

111 205

C

740

710

220 220

98

6

519

A

B

4539

C/L Top flange80

332

60

C/L Diverter switch30

24x 15

E

289

110

C/L Tap selector

INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650

750 750 1050

A 1711 a)2011 a)1491 a)1791 a)Dimen-sionsin mm

B 1192 a)1492 a)972 a) 1272 a)

C 119 a)c)119 a) 119 a)c)119 a)

D 240 c) 540 240 c) 540

Positions E

5-14 18

15-18 56

(2)1ZSC004912-AAENo. Shts.Document no.

15-18 PosA

Sheet no.OrderRevision

82 (1 Phase),E,T XXXX/450-600/C2015-02-15Swen Mattsson

LanguageUsed in productApproved by

Tap-Changer VUCGLB2015-02-15Balamurugan N

Take over departmentModified by

PPCO/TK2015-02-09Praveenkumar B

TitleResponsible departmentPrepared

V-2,4..18

Same potential as thediverter switch terminal

Shielding rings forinsulation levels 650,750 and 1050 only

Only for insulation level 1050 kV

Transformer flange

Lower ring not for short version

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity.Please refer to Technical Guidec) Not applicable for 380 kV

Contact 10 at 5-10 pos.Contact 12 at 11-12 pos.Contact 14 at 13-14 pos.Contact 16 at 15-16 pos.Contact 18 at 17-18 pos.

Only for insulation level 650, 750 and 1050 kV

H-1,3..17

Page 2: Tap-Changer VUCGLB Balamurugan N Approved by …...Balamurugan N 2015-02-15 Modified by Take over department Praveenkumar B 2015-02-09 PPCO/TK Prepared Responsible department Title

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2013 ABB. All rights reserved.

6917 028-PA(A4)Rev1

R200

36�$�

72�$�

36�$�

45�$�

45�$�

45�$� 22,5�$�

86

232

41

86

41

100

51,5�$�

25,7�$�

86

41

60�$�

60�$�

30�$�

25,7�$�

25,7�$�

20�$�

20�$�

40�$�

20�$�20�$�

100

2210

11

26

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide VUCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL:54830001-1Motor Drive BUE:54830001-2 or -3External Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1

(2)1ZSC004912-AAENo. Shts.Document no.

25-18 PosA

Sheet no.OrderRevision

82 (1 Phase),E,T XXXX/450-600/C2015-02-15Swen Mattsson

LanguageUsed in productApproved by

Tap-Changer VUCGLB2015-02-15Balamurugan N

Take over departmentModified by

PPCO/TK2015-02-09Praveenkumar B

TitleResponsible departmentPrepared

13-14 positions

P-P

17-18 positionsT=9

P-P

5-10 positions

Current collector

Current collector

381

6

94 7

2

510

R240

11-12 positions

P-P

310

94

72

116

18

512

15-16 positions

P-PA

312 5

14

9211

4

136

110

158

716

18

310

9211

4

136

512

714

P-P

312

514

716

11213

4

156

110

178 9

18

A