Tankless Rack System
By Rinnai
Rinnai’s objective:
To supply a packaged water heater solution as fully assembled systems. The system/kit would include all water/gas connections and manifolds under the units. Installer mounts rack system with any necessary venting and connects his utilities at which time the system is ready for operation
– Offerings to include;• In-Line or Wall Mount – 2 & 3 unit rack • Back to Back Mount; 2 – 4 or 3 - 6 unit rack• Rack systems can be combined in combinations up to 25 water heaters.
Ojective of Rack System
2
Features and Benefits:
•Pre-assembled rack with water heaters installed
•Racks can be used with RU98 indoor/outdoor water heaters ONLY
•In-Line or Back to Back free standing options
•Gas and water manifolds properly sized for each rack system
•Rinnai MSB electronic control system available for linking up to 25 units
•MCC-91-2 commercial controller available for temperatures between 140˚F and 185˚F
Features & Benefits
3
Features and Benefits continue:
•Flexible gas/water lines
•Drain tees for gas sediment traps
•Reinforced eyelets on back to back racks for lifting purposes
•Marine grade powered coated aluminum racks
•Fully assembled TRS (with water heaters) is designed to fit through a standard 32 inch door
Features & Benefits
4
Back to Back Assembly
5
Actual 4 Unit Back to Back Rack Assembly
Integrated Manifold
6
Integrated Manifolds for both In-line and Back to Back Rack Systems
Top Frame Center Frame
In-Line Frame Design
7
– Uni-Strut Vertical legs /Sheet Metal bracing.• Uni-Strut – Galvanized Steel• Sheet Metal is 0.090” Aluminum w/powder coat
– Frame uses (12) 5/16” threaded bolts to secure the top and center bracing.
– Use up to #10 screws to mount to wall studs, 0.219” holes are 2” apart for ease of installation
• Manifold Kits– Hot & Cold Water – Type “L” Copper – Manifolds properly sized to handle maximum flow of system – Universal manifold for hot /cold water lines– Gas – Black Iron w/powder coat
• Branch Lines– CSST ¾” from water heaters to manifolds - all connections– RIK kits include for hot/cold water feeds to manifold. – ¾” manual shut off or service valve provided for each water heater– ¾” CSST gas branch lines with yellow epoxy coating
Manifold Data
8
In-Line lifting requirements - place straps here
Back to Back lifting requirements
Proper lifting points for Rack Systems
Lifting Points
9
REU-MSB Control System:
•The MSB-M main board is supplied with (2) MSB-C1 cables, (one short & one long) to connect the first two units up to the main MSB-M board.
•Additional MSB-C1 cables will be needed to connect a third, forth or fifth unit to a MSB board. If installing more than five units the combination of MSB-M boards plus C1 and C2 cables will be determined on site based on the water heater configuration you choose.
•Up to 5 MSB-M boards can be linked together with communication cables (MSB-C2’s) allowing up to 25 water heaters to operate as a single system.
•An MSB system could have an operating range from 10,000 BTU to as great as 5 million BTU’s in terms of flow rate, from 0.4 gpm to 245 gpm.
•When multiple water heaters are linked together with MSB controls, they will attempt to supply equal amounts of hot water. They will also rotated occasionally to ensure equal usage among the entire system.
•On initial water flow 1 to 3 units will fire up based on the dip switch configuration of the Main MSB board. Once the flow rate is determined, the MSB board will cycle additional units on or off as needed. Water heaters not firing will close their servo valves.
MSB System
10
MSB Control System continue
•The temperature setting for all water heaters in a manifold system are controlled by the primary unit connected to the Main MSB board. The temperature controllers connected to other units will display the set temperature selected on the primary unit and cannot be adjusted individually. Additionally they will display error codes and can be used for diagnostics for that particular unit.
•If a water temperature over 140 ˚F is desired, the MCC-91-2 controller must be installed on the water heater with the Main MSB board.
• Dip switches on the MSB-2M board determine the number of units in standby. It is recommended that the Main MSB-M board dip switches are set for three units to be in the standby mode. All other MSB-M boards should be set to one unit in standby. Place dip switch #1 and #2 on the Main MSB-M board to the “OFF” position, this will place three units in the standby mode. Place dip switch #1 & #2 to the other MSB-M boards to the “ON” position. That will place one unit in those banks in the standby mode. The system will always allow three units to be in standby, as long as the Main MSB-M board is set to three units as explained above.
•
MSB System
11
12
MSB Control System (continued)
All MSB boards must be set up to communicate with the other boards. This is achieved by setting the dip switches on the MSB boards to the proper positions, follow steps a – e below:
MSB System
LED #6
Dip switches
a. Set dip switch #3 on the Main MSB board to the “ON” position.
b. Set dip switch #4 on the second MSB board to the “ON” position.
c. Set dip switch #3 & #4 on the third MSB board to the “ON” position.
d. Set dip switch #5 on the fourth MSB board to the “ON” position.
e. Set dip switch #3 & #5 on the fifth MSB board to the “ON” position
In all steps, LED #6 will light to confirm connection.
In-Line TRW02 Specifications
4
2
6
5
9
8
3
1
7
Water and gas flex lines are included on all rack systems.
In-Line TRW02
NO. DESCRIPTION QTY.
1 Frame, Top 1
2 Frame, Bottom 1
3 Rinnai Tankless Indoor or Outdoor Unit 2
4 Manifold, Cold Water 1
5 Manifold, Hot Water 1
6 Manifold Gas 1
7 3/4” Dirt Leg 2
8 P1000 Unistrut Channel 2
9 3/4 FNPT Brass Ball Valve - Gas 2
TRW02 Specifications
13
In-Line TRW02 Dimensions
2.000 TYP
41.420
2.710(3) Plcs
36.000
24.28
54.594
1.404
39.028
20.500 TYP
3.447
4.500
9.375
14.375
26.002
52.404 54.384
54.875
7.967 12.641
TRW02 Dimensions
14
In-Line TRW03 Specifications
4
2
6
5
8
3
1
7
9
NO. DESCRIPTION QTY.
1 Frame, Top 1
2 Frame, Bottom 1
3Rinnai Tankless Indoor or Outdoor Unit
3
4 Manifold, Cold Water 1
5 Manifold, Hot Water 1
6 Manifold, Gas 1
7 3/4” Dirt Leg 3
8 P1000 Unistrut Channel 2
93/4 FNPT Brass Ball Valve - Gas
3
Water and gas flex lines are included on all rack systems.
In-Line TRW03
TRW03 Specifications
15
In-Line TRW03 Dimensions
1.76TYP
59.53 TYP
61.92
2.71(3) Plcs
56.50
20.50 TYP
24.28
54.56
2.000 TYP
29.76
4.50
9.38
14.38
26.42
52.40 54.38
54.88
7.98 12.64
2.90
TRW03 Dimensions
16
Water and gas flex lines are included on all rack systems.
Back to Back TRS04NO. DESCRIPTION QTY.
1 Frame 1
2 Lifting Eyebolt 2
3 Rinnai Tankless Indoor or Outdoor Unit
4
4 Manifold, Cold Water 1
5 Manifold, Hot Water 1
6 Manifold, Gas 1
7 3/4” Dirt Leg 4
8 Unistrut 2
9 3/4 FNPT Brass Ball Valve - Gas 4 4
2
6
5
9
8
3
1
7
Back to Back TRS04 Specification
TRR04 Specifications
17
Back to Back TRS04 Dimensions
1.10 TYP 20.50
36.53
41.50
2.49 TYP
39.03
3.01 6.00 10.23
28.50
4.50 9.38
14.38
53.59 55.18
55.57
27.60
28.14
18.82
TRS04 Dimensions
18
Back to Back TRS06 Specification
Back to Back TRS06
NO. DESCRIPTION QTY.
1 Frame 1
2 Lifting Eyebolt 2
3 Rinnai Tankless Indoor or Outdoor Unit
6
4 Manifold, Cold Water 1
5 Manifold, Hot Water 1
6 Manifold, Gas 1
7 3/4” Dirt Leg 6
8 Unistrut 2
9 3/4 FNPT Brass Ball Valve - Gas
6
4
6
5
9
8
3
1
7
2
Water and gas flex lines are included on all rack systems.
TRS06 Specifications
19
Back to Back TRS06 Dimensions
20.50 TYP
55.11 62.00
3.45 TYP 2.05
9.17 4.95
59.53
2.08 TYP 18.81
4.50 9.38
14.38
55.18 55.57
28.50
27.61
28.13
TRS06 Dimensions
20
Rack System Examples
21
In-Line Application
Back to Back Application
Rack System Examples
22
Back to Back Application
Rack System Examples
23
Back to Back Application
to side
to front
to top
to floor/ground
to side
to front
to top
to floor/ground
to Combustibles
inches (mm)
to Non-Combustibles
inches (mm)
Top of Heater 6 * (152) 2 *(51)
Back of Heater 0 (zero) 0 (zero)
Front of Heater
6 (152) 6 (152)
Sides of Heater
2 (51) 1/2 (13)
Ground/Bottom
12 (305) 12 (305)
Vent 0 (zero) 0 (zero)
to Combustibles
inches (mm)
to Non-Combustibles
inches (mm)
Top of Heater 12 (305) 2 (51)
Back of Heater 0 (zero) 0 (zero)
Front (panel) 24 (610) 0 (zero)
Front (exhaust)24 (610) 24 (610)
Sides of Heater6 (152) 1/8 (3.2)
Ground/Bottom12 (305) 2 (51)
Indoor models: RU98i Outdoor models: RU98e
Install the rack system per clearances shown below for the RU98i and RU98e water heaters
Clearances for Water Heaters
24
Manifold Design for 24 W/H’s2 ½”, 4” and 6” Water Manifolds/Connections
Piping Layout - 24 Units
25
Multiple rack systems MUST pipe in parallel as shown below. Piping systems in series will result in undersized water/gas lines.
Detailed Piping - 24 Units
26
Tankless Rack System Kit Components
Rack System Kit Components
27
Part No.* Rack type Rack P/N Configuration
TRW02iN 2-unit interior In-line rack, NG RW2
TRW02eN 2-unit exterior In-line rack, NG RW2
TRW02iP 2-unit interior In-line rack, LP RW2
TRW02eP 2-unit exterior In-line rack, LP RW2
TRW03iN 3-unit interior In-line rack, NG RW3
TRW03eN 3-unit exterior In-line rack, NG RW3
TRW03iP 3-unit interior In-line rack, LP RW3
TRW03eP 3-unit exterior In-line rack, LP RW3
Tankless Rack System Kit Components
28
Rack System Kit Components
TRS02iN 2-unit interior back to back rack, NG RS4
TRS02eN 2-unit exterior back to back rack, NG RS4
TRS02iP 2-unit interior back to back rack, LP RS4
TRS02eP 2-unit exterior back to back rack, LP RS4
TRS02iN-IL 2-unit INLINE interior back to back rack, NG RS4
TRS02eN-IL 2-unit INLINE exterior back to back rack, NG RS4
TRS02iP-IL 2-unit INLINE interior back to back rack, LP RS4
TRS02eP-IL 2-unit INLINE exterior back to back rack, LP RS4
TRS03iN 3-unit interior back to back rack, NG RS4
TRS03eN 3-unit exterior back to back rack, NG RS4
TRS03iP 3-unit interior back to back rack, LP RS4
TRS03eP 3-unit exterior back to back rack, LP RS4
TRS04iN 4-unit interior back to back rack, NG RS4
TRS04eN 4-unit exterior back to back rack, NG RS4
TRS04iP 4-unit interior back to back rack, LP RS4
TRS04eP 4-unit exterior back to back rack, LP RS4
Tankless Rack System Kit Components
29
Rack System Kit Components
TRS03iN-IL 3-unit INLINE interior back to back rack, NG RS6
TRS03eN-IL 3-unit INLINE exterior back to back rack, NG RS6
TRS03iP-IL 3-unit INLINE interior back to back, LP RS6
TRS03eP-IL 3-unit INLINE exterior back to back rack, LP RS6
TRS05iN 5-unit interior back to back rack, NG RS6
TRS05eN 5-unit exterior back to back rack, NG RS6
TRS05iP 5-unit interior back to back rack, LP RS6
TRS05eP 5-unit exterior back to back rack, LP RS6
TRS06iN 6-unit interior back to back rack, NG RS6
TRS06eN 6-unit exterior back to back rack, NG RS6
TRS06iP 6-unit interior back to back rack, LP RS6
TRS06eP 6-unit exterior back to back rack, LP RS6
Description(2) RU98
In-Line Mount(3) RU98
In-Line Mount
Top Level Part No. RW2 RW3
Rack Frame - Specifications RW2 RW3
Water Heater Model Number RU98i/eN/P RU98i/eN/P
Height - in 54.81 54.81
Length - in 41.50 62.00
Depth - in 12.75 12.75
Crate Dimensions (LxWxH) - in 62 x 55 x 36 62 x 75 x 36
Weight - Assembly w/o WHs - lbs 44.1 63.4
Weight - Water Heaters - lbs 131.4 197.1
Weight - Fully Assembled - lbs 175.5 260.5
Weight - Packaging - lbs 121.0 142.0
Weight - Shipping (total) - lbs 296.5 402.5
Material Detail List
Material Details
30
Description(4/4) RU98
Back to Back (3/4) RU98
Back to Back(2/4) RU98
Back to Back
Top Level Part No. RS4-4 RS4-3 RS4-2
Rack Frame - Specifications RF4 RF4 RF4
Water Heater Model Number RU98i/eN/P RU98i/eN/P RU98i/eN/P
Frame (HxLxD) - in 55.56 x 41.50 x 28.5
Crate Dimensions (HxLxD) - in 62 x 55 x 36
Weight - Assembly w/o WHs - lbs 96.1 88.1 80.1
Weight - Water Heaters - lbs 262.8 197.1 131.4
Weight - Fully Assembled - lbs 358.9 285.2 211.5
Weight - Packaging - lbs 129.0 129.0 129.0
Weight - Shipping (total) - lbs 487.9 414.2 340.5
Material Detail List
Material Details
31
Material Detail List
Description(6/6) RU98
Back to Back(5/6) RU98
Back to Back(3/6) RU98
Back to Back
Top Level Part No. RS6-6 RS6-5 RS6-3
Rack Frame - Specifications RF6 RF6 RF6
Water Heater Model Number RU98i/eN/P RU98i/eN/P RU98i/eN/P
Frame (HxLxD) – in 55.56 x 62.00 x 28.5
Crate Dimensions (LxWxH) - in 62x75x36
Weight - Assembly w/o WHs - lbs 124.6 116.6 100.6
Weight - Water Heaters - lbs 394.2 328.5 197.1
Weight - Fully Assembled - lbs 518.8 445.1 350.2
Weight - Packaging - lbs 148.0 148.0 148.0
Weight - Shipping (total) - lbs 666.8 593.1 498.2
Material Details
32
Description(2, 3) RU98
In-Line Mount(4/4, 3/4, or 2/4) RU98
Back to Back (b) (6/6, 5/6, 3/6) RU98Back to Back (b)
Top Level Part No. RW2, RW3 RS4-4, RS4-3, RS4-2 RS6-6, RS6-5, RS6-3
Rack Frame - Specifications RW2, RW3 RF4 RF6
Frame Rail Type Sheet Metal Sheet Metal Sheet Metal
Frame Material 0.090 5052-H32 0.090 5052-H32 0.090 5052-H32
Frame Finish Powder Coat Powder Coat Powder Coat
Color Gray Gray Gray
Water & Gas Connections
Hot Water Trunk Line Diameter 2" 2" 2-1/2"
Cold Water Trunk Line Diameter 2" 2" 2-1/2"
Hot Water Trunk Line Material Rigid Copper Rigid Copper Rigid Copper
Cold Water Trunk Line Material Rigid Copper Rigid Copper Rigid Copper
Water Trunk Connection Type 2" MNPT 2" MNPT 2-1/2" MNPT
Water Header End Cap (field supplied) 2” FNPT 2” FNPT 2-1/2” FNPT
Hot Water Branch Line Diameter 3/4" 3/4" 3/4"
Cold Water Branch Line Diameter 3/4" 3/4" 3/4"
Hot Water Branch Line Material CSST CSST CSST
Material Detail List
Materials Details
33
Cold Water Branch Line Material CSST CSST CSST
Gas Trunk Line Diameter 1-1/4" NPT 1-1/4" NPT 1-1/2" NPT
Gas Trunk Connection Type 1-1/4” MNPT 1-1/4” MNPT 1-1/2” MNPT
Gas Header End Cap (field supplied) 1-1/4” FNPT 1-1/4” FNPT 1-1/2” FNPT
Gas Trunk Line Material Sch 40 Steel Sch 40 Steel Sch 40 Steel
Gas Branch Line Diameter 3/4" 3/4" 3/4"
Gas Branch Line Material PVC over CSST PVC over CSST PVC over CSST
Gas Trunk Line Finish Powder Coat Powder Coat Powder Coat
Uni-Strut Size 1-5/8" x 13/16" 1-5/8" x 1-5/8" 1-5/8" x 1-3/8"
Uni-Strut Material 14ga Steel / Zn 12ga S/S 12ga S/S
Hardware Material/Finish Steel / Zn S/S 18-8 S/S 18-8
Material Detail List continue from previous slide
Material Details
34
BTU and Flow Rates for Common Vented RU98i/e (NG/LP)
2 RU98 3 RU98 4 RU98 6 RU98
Flow rate @ 70°F temperature rise (gpm) 10.8 16.2 21.6 32.4
Flow rate @ 100°F temperature rise (gpm) 7.6 11.4 15.2 22.8
Maximum input rate (Btuh) 398,000 597,000 796,000 1,194,000
Electrical Requirements
(Installer shall provide electrical outlet connections) Each unit has a 10 amp fuse.
Maximum circuit for each RU98 unit without a built-in circulation pump is 4 amps.
Each water heater requires 120 VAC, 60 Hz. 4 amp power source in a properly grounded circuit.
RU98i: 64 W normal operation; 2 W standby; 146 W anti-frost
protection.
RU98e: 63 W normal operation; 2 W standby; 168 W anti-frost protection.
Electrical /BTU Input Ratings
Electrical/Flow Ratings
35
The End
Rinnai
Rack System Training
Version 02282014GW