Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor...
-
date post
20-Dec-2015 -
Category
Documents
-
view
215 -
download
1
Transcript of Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor...
![Page 1: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/1.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Laser interferometric beam size monitor(Shintake-monitor)
![Page 2: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/2.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Baseline Layout
2.5m spacing from bend to dump.Edge of the dump is at ~10cm beyond the beam line.
![Page 3: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/3.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Photons from beam pipe
70~90% of photons (by electrons interacting with pipe)come forward, up to beam energy (1.3GeV)
![Page 4: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/4.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Photons from beam pipe
No energy dependence for position of detector.
![Page 5: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/5.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Photons from beam pipe
Spread over beam pipe (signal is focused to center)
![Page 6: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/6.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Photons from beam pipe
![Page 7: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/7.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Photons from beam pipe
• Energy spectrum is broad up to 1.3GeV• The rate seems to be very high
(with no collimeter)– 0.7~0.9 photons for 1 collision to pipe
• Position is much spread than signal
![Page 8: Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27 Laser interferometric beam size monitor (Shintake-monitor)](https://reader036.fdocuments.in/reader036/viewer/2022062714/56649d405503460f94a1af26/html5/thumbnails/8.jpg)
Taikan SUEHARA, ILC-Asia wg4 meeting @ KEK, 2005/7/27
Shipping
• Optical table– Returned back to Nittsu because of some probl
em of carry-in (and bad weather)– Retry tomorrow with some attachments
• Other components– Have carried-in in Hongo– Now checking