SUBMITTAL
© 2018 Ingersoll Rand All Rights Reserved
TAG: _________________________________
15 SERIES
Multi Zone Mini-SplitInverter System
M4THM1518A12NA
M4THM1518A-SUB-1B-EN
Specifications
MODEL - Heat Pump Only
RATED Volts/PHFrequency (Hz)
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
M4THM1518A12NA
208 / 230 / 1 60Hz
M4THM1518A12NA18000
7000 - 2100019000
8530 - 226009600 8600
15.0 / 8.210.0
Inverter Rotary27
9.561245EEV
0 ~ 118 5 ~ 75Aluminum Fin-Copper Tube
5/162 - 0.055
30.6 x 1.5 x 21.7830 / 670 / 500
600.5420
153017.5
Automatic Defrosting6656
35.4 x 14.9 x 23.537.3 x 16.5 x 25.4
94.8 / 105.847.6313.020.0
1/43/81/43/8//////
163375
35.4
32.1
23.5
14.9
12.4
13.5
21.6
18K Unit
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
Calculation of the Additional Refrigerant Charge: Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
Ductless Multi-Zone Approved Combinations
Ductless Multi-Zone Quick ReferenceMulti-Zone Heat Pumps Outdoor
18,000 BTUH 24,000 BTUH 30,000 BTUH 36,000 BTUH 42,000 BTUH
M4THM1518A12N M4THM1524A13N M4THM1530A14N M4THM1536A14N M4THM1542A15N
Multi-Zone Heat Pumps Indoor Options
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
High-Wall Mounted M4MHW1509A1N M4MHW1512A1N M4MHW1518A1N M4MHW1524A1N
Indoor Unit Combinations with Associated Nominal Capacity (kBTUH)
Outdoor Unit One Unit Two Units
M4THM1518A12N
18,000 BTUH
9 9+9 12+12
12 9+12
Outdoor Unit Two Units Three Units
M4THM1524A13N
24,000 BTUH
9+9 9+12 9+9+9 9+12+12 12+12+12
9+18 12+12 9+9+12 9+9+18
12+18 18+18
Outdoor Unit Two Units Three Units Four Units
M4THM1530A14N
30,000 BTUH
9+9 9+12 9+9+9 9+9+12 9+9+18 9+9+9+9 9+9+9+12 9+9+12+12
9+18 12+12 9+12+12 9+12+18 12+12+12
12+18 18+18 12+12+18
Outdoor Unit Two Units Three Units Four Units
M4THM1536A14N
36,000 BTUH
9+9 12+18 9+9+9 9+12+18 12+12+18 9+9+9+9 9+9+12+18
9+12 12+24 9+9+12 9+12+24 12+12+24 9+9+9+12 9+9+18+18
9+18 18+18 9+9+18 9+18+18 12+18+18 9+9+9+18 9+12+12+12
9+24 18+24 9+9+24 9+18+24 18+18+18 9+9+9+24 9+12+12+18
12+12 24+24 9+12+12 12+12+12 9+9+12+12 12+12+12+12
Outdoor Unit Two Units Three Units Four Units Five Units
M4THM1542A15N
42,000 BTUH
9+9 12+18 9+9+9 9+12+24 12+12+24 9+9+9+9 9+9+12+24 9+12+18+18 9+9+9+9+9 9+9+9+18+18
9+12 12+24 9+9+12 9+18+18 12+18+18 9+9+9+12 9+9+18+18 9+18+18+18 9+9+9+9+12 9+9+12+12+12
9+18 18+18 9+9+18 9+18+24 12+18+24 9+9+9+18 9+9+18+24 12+12+12+12 9+9+9+9+18 9+9+12+12+18
9+24 18+24 9+9+24 9+24+24 12+24+24 9+9+9+24 9+12+12+12 12+12+12+18 9+9+9+9+24 9+12+12+12+12
12+12 24+24 9+12+12 12+12+12 18+18+18 9+9+12+12 9+12+12+18 12+12+12+24 9+9+9+12+12 9+12+12+12+18
9+12+18 12+12+18 18+18+24 9+9+12+18 9+12+12+24 12+12+18+18 9+9+9+12+18 12+12+12+12+12
PERFORMANCE DATA
TC* SHC** TC SHC TC SHC TC SHC65 17100 13400 18100 14200 19200 15100 20700 1620070 16700 13100 17700 13900 19000 14900 20400 1600075 16300 12800 17300 13600 18800 14800 20200 1580080 16000 12600 17100 13400 18600 14600 19900 1560085 15800 12400 16900 13200 18400 14400 19700 1550090 15600 12200 16700 13100 18200 14300 19700 1540095 15400 12100 16500 12900 18000 14100 19700 15400100 15100 11800 16200 12700 17900 14000 19400 15200105 14700 11600 15800 12400 17700 13900 19100 15000110 14300 11200 15400 12100 17300 13500 18700 14600115 13900 10900 15000 11700 16900 13200 18200 14300
TC* TC TC TC0 13400 13100 12900 126005 14300 14100 13800 1350010 14900 14700 14400 1410015 15400 15200 14900 1460020 16000 15700 15400 1510025 16500 16300 16000 1570030 17100 16900 16600 1630035 17500 17300 17000 1670040 17800 17600 17300 1710045 18700 18500 18100 1770050 19300 19000 18600 1820055 19600 19300 18900 1840060 19900 19500 19100 18700
M4THM1518A1 ‐ Cooling Mode Performance Data
M4THM1518A1 ‐ Heating Mode Performance Data
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature
68°F 73°F 80°F 82°F
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature (Dry Bulb/Wet Bulb)
68/57°F 73/61°F 80/67°F 82/68°F
*Total Capacity **Sensible Heat Capacity
*Total Capacity
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
Mechanical Specifications
01/18
Optional Equipment
Optional outdoor unit accessories M4THM15Model Multi-ZoneNumber Description up to 15 SEERTAYREFLN050 ....................... Lineset Kit 1/4x3/8 - 25' .................................................................. ✔
TAYREFLN055 ....................... Lineset Kit 1/4x3/8 - 35' .................................................................. ✔
TAYREFLN060 ....................... Lineset Kit 1/4x3/8 - 50' .................................................................. ✔
TAYREFLN560 ....................... Lineset Kit 1/4x1/2 - 25' .................................................................. ✔
TAYREFLN565 ....................... Lineset Kit 1/4x1/2 - 35' .................................................................. ✔
TAYREFLN570 ....................... Lineset Kit 1/4x1/2 - 50' .................................................................. ✔
TAYREFLN155 ....................... Lineset Kit 1/4x5/8 - 25' .................................................................. ✔
TAYREFLN160 ....................... Lineset Kit 1/4x5/8 - 35' .................................................................. ✔
TAYREFLN165 ....................... Lineset Kit 1/4x5/8 - 50' .................................................................. ✔
Multi-Zone Outdoor Unit
General
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
SUBMITTAL
© 2018 Ingersoll Rand All Rights Reserved
TAG: _________________________________
15 SERIES
Multi Zone Mini-SplitInverter System
M4THM1524A13NA
M4THM1524A-SUB-1B-EN
Specifications
MODEL - Heat Pump Only
RATED Volts/PHFrequency (Hz)
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
M4THM1524A13NA
208 / 230 / 1 60Hz
M4THM1524A13NA26000
7500 - 3300029000
7500 - 350001500012100
15.0 / 8.28.0
Inverter Rotary45
14.692200EEV
0 ~ 118 5 ~ 75Aluminum Fin-Copper Tube
3/82 - 0.055
35.0 x 1.7 x 25.0690 / 600 / 500
600.5930
153020.5
Automatic Defrosting6656
37.2 x 15.6 x 27.640.5 x 18.0 x 29.5
134.5 / 145.577.6220.030.0
1/43/81/43/81/43/8////
3365230
35.1
37.2
27.6
15.6
13.4
22.014
.5
24K-30K Unit
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
Calculation of the Additional Refrigerant Charge:
Indoor Unit Combinations with Associated Nominal Capacity (kBTUH)
Outdoor Unit One Unit Two Units
M4THM1518A12N
18,000 BTUH
9 9+9 12+12
12 9+12
Outdoor Unit Two Units Three Units
M4THM1524A13N
24,000 BTUH
9+9 9+12 9+9+9 9+12+12 12+12+12
9+18 12+12 9+9+12 9+9+18
12+18 18+18
Outdoor Unit Two Units Three Units Four Units
M4THM1530A14N
30,000 BTUH
9+9 9+12 9+9+9 9+9+12 9+9+18 9+9+9+9 9+9+9+12 9+9+12+12
9+18 12+12 9+12+12 9+12+18 12+12+12
12+18 18+18 12+12+18
Outdoor Unit Two Units Three Units Four Units
M4THM1536A14N
36,000 BTUH
9+9 12+18 9+9+9 9+12+18 12+12+18 9+9+9+9 9+9+12+18
9+12 12+24 9+9+12 9+12+24 12+12+24 9+9+9+12 9+9+18+18
9+18 18+18 9+9+18 9+18+18 12+18+18 9+9+9+18 9+12+12+12
9+24 18+24 9+9+24 9+18+24 18+18+18 9+9+9+24 9+12+12+18
12+12 24+24 9+12+12 12+12+12 9+9+12+12 12+12+12+12
Outdoor Unit Two Units Three Units Four Units Five Units
M4THM1542A15N
42,000 BTUH
9+9 12+18 9+9+9 9+12+24 12+12+24 9+9+9+9 9+9+12+24 9+12+18+18 9+9+9+9+9 9+9+9+18+18
9+12 12+24 9+9+12 9+18+18 12+18+18 9+9+9+12 9+9+18+18 9+18+18+18 9+9+9+9+12 9+9+12+12+12
9+18 18+18 9+9+18 9+18+24 12+18+24 9+9+9+18 9+9+18+24 12+12+12+12 9+9+9+9+18 9+9+12+12+18
9+24 18+24 9+9+24 9+24+24 12+24+24 9+9+9+24 9+12+12+12 12+12+12+18 9+9+9+9+24 9+12+12+12+12
12+12 24+24 9+12+12 12+12+12 18+18+18 9+9+12+12 9+12+12+18 12+12+12+24 9+9+9+12+12 9+12+12+12+18
9+12+18 12+12+18 18+18+24 9+9+12+18 9+12+12+24 12+12+18+18 9+9+9+12+18 12+12+12+12+12
Ductless Multi-Zone Approved Combinations
Ductless Multi-Zone Quick ReferenceMulti-Zone Heat Pumps Outdoor
18,000 BTUH 24,000 BTUH 30,000 BTUH 36,000 BTUH 42,000 BTUH
M4THM1518A12N M4THM1524A13N M4THM1530A14N M4THM1536A14N M4THM1542A15N
Multi-Zone Heat Pumps Indoor Options
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
High-Wall Mounted M4MHW1509A1N M4MHW1512A1N M4MHW1518A1N M4MHW1524A1N
PERFORMANCE DATA
TC* SHC** TC SHC TC SHC TC SHC65 22700 17800 24200 18900 25600 20100 27500 2160070 22200 17400 23600 18500 25400 19900 27200 2130075 21700 17100 23100 18100 25100 19700 26900 2110080 21400 16800 22700 17800 24800 19500 26600 2090085 21100 16500 22500 17600 24500 19300 26300 2060090 20800 16300 22200 17400 24300 19000 26200 2060095 20500 16100 21900 17200 24000 18800 26200 20600100 20100 15800 21500 16900 23800 18700 25800 20300105 19700 15500 21100 16600 23600 18500 25500 20000110 19400 15200 20900 16400 23400 18300 25200 19800115 19100 15000 20600 16100 23100 18100 24900 19600
TC* TC TC TC0 20400 20100 19700 192005 21900 21500 21100 2060010 22800 22400 22000 2150015 23600 23200 22700 2220020 24400 24000 23500 2300025 25200 24900 24400 2390030 26100 25800 25400 2490035 26700 26400 26000 2560040 27200 26800 26500 2600045 28600 28200 27700 2710050 29500 29000 28400 2780055 29900 29400 28800 2810060 30300 29800 29200 28500
M4THM1524A1 ‐ Heating Mode Performance Data
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature (Dry Bulb/Wet Bulb)
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature
68/57°F 73/61°F 80/67°F 82/68°F
M4THM1524A1 ‐ Cooling Mode Performance Data
68°F 73°F 80°F 82°F
*Total Capacity
*Total Capacity **Sensible Heat Capacity
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
Mechanical Specifications
01/18
Optional Equipment
Optional outdoor unit accessories M4THM15Model Multi-ZoneNumber Description up to 15 SEERTAYREFLN050 ....................... Lineset Kit 1/4x3/8 - 25' .................................................................. ✔
TAYREFLN055 ....................... Lineset Kit 1/4x3/8 - 35' .................................................................. ✔
TAYREFLN060 ....................... Lineset Kit 1/4x3/8 - 50' .................................................................. ✔
TAYREFLN560 ....................... Lineset Kit 1/4x1/2 - 25' .................................................................. ✔
TAYREFLN565 ....................... Lineset Kit 1/4x1/2 - 35' .................................................................. ✔
TAYREFLN570 ....................... Lineset Kit 1/4x1/2 - 50' .................................................................. ✔
TAYREFLN155 ....................... Lineset Kit 1/4x5/8 - 25' .................................................................. ✔
TAYREFLN160 ....................... Lineset Kit 1/4x5/8 - 35' .................................................................. ✔
TAYREFLN165 ....................... Lineset Kit 1/4x5/8 - 50' .................................................................. ✔
Multi-Zone Outdoor Unit
General
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
SUBMITTAL
© 2018 Ingersoll Rand All Rights Reserved
TAG: _________________________________
15 SERIES
Multi Zone Mini-SplitInverter System
M4THM1530A14NA
M4THM1530A-SUB-1B-EN
Specifications
M4THM1530A14NA
208 / 230 / 1 60Hz
M4THM1530A14NA29000
7500 - 3400030500
7500 - 360001650013300
15.0 / 8.28.0
Inverter Rotary45
19.622200EEV
0 ~ 118 5 ~ 75Aluminum Fin-Copper Tube
3/82 - 0.055
35.0 x 1.7 x 25.0690 / 600 / 500
600.5945
153020.5
Automatic Defrosting6656
37.2 x 15.6 x 27.640.5 x 18.0 x 29.5
136.7 / 147.777.6226.045.0
1/43/81/43/81/43/81/43/8//
3365230
MODEL - Heat Pump Only
RATED Volts/PHFrequency (Hz)
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
35.1
37.2
27.6
15.6
13.4
22.014
.5
24K-30K Unit
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
Calculation of the Additional Refrigerant Charge:
Ductless Multi-Zone Approved Combinations
Ductless Multi-Zone Quick ReferenceMulti-Zone Heat Pumps Outdoor
18,000 BTUH 24,000 BTUH 30,000 BTUH 36,000 BTUH 42,000 BTUH
M4THM1518A12N M4THM1524A13N M4THM1530A14N M4THM1536A14N M4THM1542A15N
Multi-Zone Heat Pumps Indoor Options
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
High-Wall Mounted M4MHW1509A1N M4MHW1512A1N M4MHW1518A1N M4MHW1524A1N
Indoor Unit Combinations with Associated Nominal Capacity (kBTUH)
Outdoor Unit One Unit Two Units
M4THM1518A12N
18,000 BTUH
9 9+9 12+12
12 9+12
Outdoor Unit Two Units Three Units
M4THM1524A13N
24,000 BTUH
9+9 9+12 9+9+9 9+12+12 12+12+12
9+18 12+12 9+9+12 9+9+18
12+18 18+18
Outdoor Unit Two Units Three Units Four Units
M4THM1530A14N
30,000 BTUH
9+9 9+12 9+9+9 9+9+12 9+9+18 9+9+9+9 9+9+9+12 9+9+12+12
9+18 12+12 9+12+12 9+12+18 12+12+12
12+18 18+18 12+12+18
Outdoor Unit Two Units Three Units Four Units
M4THM1536A14N
36,000 BTUH
9+9 12+18 9+9+9 9+12+18 12+12+18 9+9+9+9 9+9+12+18
9+12 12+24 9+9+12 9+12+24 12+12+24 9+9+9+12 9+9+18+18
9+18 18+18 9+9+18 9+18+18 12+18+18 9+9+9+18 9+12+12+12
9+24 18+24 9+9+24 9+18+24 18+18+18 9+9+9+24 9+12+12+18
12+12 24+24 9+12+12 12+12+12 9+9+12+12 12+12+12+12
Outdoor Unit Two Units Three Units Four Units Five Units
M4THM1542A15N
42,000 BTUH
9+9 12+18 9+9+9 9+12+24 12+12+24 9+9+9+9 9+9+12+24 9+12+18+18 9+9+9+9+9 9+9+9+18+18
9+12 12+24 9+9+12 9+18+18 12+18+18 9+9+9+12 9+9+18+18 9+18+18+18 9+9+9+9+12 9+9+12+12+12
9+18 18+18 9+9+18 9+18+24 12+18+24 9+9+9+18 9+9+18+24 12+12+12+12 9+9+9+9+18 9+9+12+12+18
9+24 18+24 9+9+24 9+24+24 12+24+24 9+9+9+24 9+12+12+12 12+12+12+18 9+9+9+9+24 9+12+12+12+12
12+12 24+24 9+12+12 12+12+12 18+18+18 9+9+12+12 9+12+12+18 12+12+12+24 9+9+9+12+12 9+12+12+12+18
9+12+18 12+12+18 18+18+24 9+9+12+18 9+12+12+24 12+12+18+18 9+9+9+12+18 12+12+12+12+12
PERFORMANCE DATA
TC* SHC** TC SHC TC SHC TC SHC65 27500 21600 29200 22900 31000 24300 33300 2610070 26900 21100 28600 22400 30700 24100 32900 2580075 26300 20600 27900 21900 30400 23800 32500 2550080 25900 20300 27500 21600 30000 23500 32200 2520085 25500 20000 27200 21300 29700 23300 31800 2500090 25200 19700 26900 21100 29400 23000 31700 2490095 24800 19400 26500 20800 29000 22800 31700 24900100 24300 19100 26000 20400 28800 22600 31300 24500105 23800 18700 25600 20100 28600 22400 30800 24200110 23500 18400 25200 19800 28300 22200 30500 23900115 23200 18200 24900 19500 27900 21900 30200 23700
TC* TC TC TC0 21500 21100 20700 202005 23000 22600 22200 2170010 24000 23600 23100 2260015 24800 24400 23900 2340020 25600 25200 24700 2420025 26600 26200 25700 2520030 27500 27100 26700 2620035 28100 27800 27300 2690040 28600 28200 27800 2740045 30100 29600 29100 2850050 31100 30500 29900 2920055 31500 30900 30300 2960060 31900 31300 30700 30000
M4THM1530A1 ‐ Heating Mode Performance Data
M4THM1530A1 ‐ Cooling Mode Performance Data
*Total Capacity
*Total Capacity **Sensible Heat Capacity
80°F 82°F
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature (Dry Bulb/Wet Bulb)
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature
68/57°F 73/61°F 80/67°F 82/68°F
68°F 73°F
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
Mechanical Specifications
01/18
Optional Equipment
Optional outdoor unit accessories M4THM15Model Multi-ZoneNumber Description up to 15 SEERTAYREFLN050 ....................... Lineset Kit 1/4x3/8 - 25' .................................................................. ✔
TAYREFLN055 ....................... Lineset Kit 1/4x3/8 - 35' .................................................................. ✔
TAYREFLN060 ....................... Lineset Kit 1/4x3/8 - 50' .................................................................. ✔
TAYREFLN560 ....................... Lineset Kit 1/4x1/2 - 25' .................................................................. ✔
TAYREFLN565 ....................... Lineset Kit 1/4x1/2 - 35' .................................................................. ✔
TAYREFLN570 ....................... Lineset Kit 1/4x1/2 - 50' .................................................................. ✔
TAYREFLN155 ....................... Lineset Kit 1/4x5/8 - 25' .................................................................. ✔
TAYREFLN160 ....................... Lineset Kit 1/4x5/8 - 35' .................................................................. ✔
TAYREFLN165 ....................... Lineset Kit 1/4x5/8 - 50' .................................................................. ✔
Multi-Zone Outdoor Unit
General
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
SUBMITTAL
© 2018 Ingersoll Rand All Rights Reserved
TAG: _________________________________
15 SERIES
Multi Zone Mini-SplitInverter System
M4THM1536A14NA
M4THM1536A-SUB-1B-EN
Specifications
M4THM1536A14NA
208 / 230 / 1 60Hz
M4THM1536A14NA34000
8530 - 3410035800
10660 - 409002200014400
15.0 / 8.27.75
Inverter Rotary45
21.02200EEV
0 ~ 118 5 ~ 75Aluminum Fin-Copper Tube
5/82 - 0.063
35.8 x 1.5 x 29.4820 / 640 / 560
1200.6745
217721.7
Automatic Defrosting6959
39.1 x 16.8 x 31.142.6 x 19.2 x 33.7
152.6 / 165.2102.3128.045.0
1/43/81/43/81/41/23/85/8//
5065230
MODEL - Heat Pump Only
RATED Volts/PHFrequency (Hz)
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
16.839.1
36.2
24.0
14.6
31.1
15.6
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
Calculation of the Additional Refrigerant Charge:
Ductless Multi-Zone Approved Combinations
Ductless Multi-Zone Quick ReferenceMulti-Zone Heat Pumps Outdoor
18,000 BTUH 24,000 BTUH 30,000 BTUH 36,000 BTUH 42,000 BTUH
M4THM1518A12N M4THM1524A13N M4THM1530A14N M4THM1536A14N M4THM1542A15N
Multi-Zone Heat Pumps Indoor Options
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
High-Wall Mounted M4MHW1509A1N M4MHW1512A1N M4MHW1518A1N M4MHW1524A1N
Indoor Unit Combinations with Associated Nominal Capacity (kBTUH)
Outdoor Unit One Unit Two Units
M4THM1518A12N
18,000 BTUH
9 9+9 12+12
12 9+12
Outdoor Unit Two Units Three Units
M4THM1524A13N
24,000 BTUH
9+9 9+12 9+9+9 9+12+12 12+12+12
9+18 12+12 9+9+12 9+9+18
12+18 18+18
Outdoor Unit Two Units Three Units Four Units
M4THM1530A14N
30,000 BTUH
9+9 9+12 9+9+9 9+9+12 9+9+18 9+9+9+9 9+9+9+12 9+9+12+12
9+18 12+12 9+12+12 9+12+18 12+12+12
12+18 18+18 12+12+18
Outdoor Unit Two Units Three Units Four Units
M4THM1536A14N
36,000 BTUH
9+9 12+18 9+9+9 9+12+18 12+12+18 9+9+9+9 9+9+12+18
9+12 12+24 9+9+12 9+12+24 12+12+24 9+9+9+12 9+9+18+18
9+18 18+18 9+9+18 9+18+18 12+18+18 9+9+9+18 9+12+12+12
9+24 18+24 9+9+24 9+18+24 18+18+18 9+9+9+24 9+12+12+18
12+12 24+24 9+12+12 12+12+12 9+9+12+12 12+12+12+12
Outdoor Unit Two Units Three Units Four Units Five Units
M4THM1542A15N
42,000 BTUH
9+9 12+18 9+9+9 9+12+24 12+12+24 9+9+9+9 9+9+12+24 9+12+18+18 9+9+9+9+9 9+9+9+18+18
9+12 12+24 9+9+12 9+18+18 12+18+18 9+9+9+12 9+9+18+18 9+18+18+18 9+9+9+9+12 9+9+12+12+12
9+18 18+18 9+9+18 9+18+24 12+18+24 9+9+9+18 9+9+18+24 12+12+12+12 9+9+9+9+18 9+9+12+12+18
9+24 18+24 9+9+24 9+24+24 12+24+24 9+9+9+24 9+12+12+12 12+12+12+18 9+9+9+9+24 9+12+12+12+12
12+12 24+24 9+12+12 12+12+12 18+18+18 9+9+12+12 9+12+12+18 12+12+12+24 9+9+9+12+12 9+12+12+12+18
9+12+18 12+12+18 18+18+24 9+9+12+18 9+12+12+24 12+12+18+18 9+9+9+12+18 12+12+12+12+12
PERFORMANCE DATA
TC* SHC** TC SHC TC SHC TC SHC65 35400 27800 37700 29500 40000 31400 42900 3370070 34100 26800 36300 28500 38900 30500 41800 3280075 32800 25800 34900 27400 37900 29700 40600 3190080 31800 24900 33800 26500 36900 28900 39500 3100085 30900 24200 32900 25800 35900 28200 38500 3020090 29900 23500 32000 25100 34900 27400 37700 2960095 29000 22800 31100 24300 34000 26700 37100 29100100 28400 22300 30500 23900 33800 26500 36600 28700105 27900 21900 29900 23500 33500 26300 36100 28300110 27500 21600 29600 23200 33100 25900 35700 28000115 27100 21300 29200 22900 32700 25600 35300 27700
TC* TC TC TC0 25200 24800 24300 237005 27000 26600 26100 2550010 28100 27700 27100 2650015 29100 28600 28100 2740020 30100 29600 29000 2840025 31200 30700 30200 2950030 32300 31800 31300 3070035 33000 32600 32100 3150040 33500 33100 32700 3210045 35300 34800 34100 3340050 36500 35800 35100 3430055 37000 36300 35600 3470060 37500 36800 36100 35200
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature (Dry Bulb/Wet Bulb)
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature
68/57°F 73/61°F 80/67°F 82/68°F
68°F 73°F 80°F 82°F
M4THM1536A1 ‐ Heating Mode Performance Data
M4THM1536A1 ‐ Cooling Mode Performance Data
*Total Capacity **Sensible Heat Capacity
*Total Capacity
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
Mechanical Specifications
01/18
Optional Equipment
Optional outdoor unit accessories M4THM15Model Multi-ZoneNumber Description up to 15 SEERTAYREFLN050 ....................... Lineset Kit 1/4x3/8 - 25' .................................................................. ✔
TAYREFLN055 ....................... Lineset Kit 1/4x3/8 - 35' .................................................................. ✔
TAYREFLN060 ....................... Lineset Kit 1/4x3/8 - 50' .................................................................. ✔
TAYREFLN560 ....................... Lineset Kit 1/4x1/2 - 25' .................................................................. ✔
TAYREFLN565 ....................... Lineset Kit 1/4x1/2 - 35' .................................................................. ✔
TAYREFLN570 ....................... Lineset Kit 1/4x1/2 - 50' .................................................................. ✔
TAYREFLN155 ....................... Lineset Kit 1/4x5/8 - 25' .................................................................. ✔
TAYREFLN160 ....................... Lineset Kit 1/4x5/8 - 35' .................................................................. ✔
TAYREFLN165 ....................... Lineset Kit 1/4x5/8 - 50' .................................................................. ✔
Multi-Zone Outdoor Unit
General
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
SUBMITTAL
© 2018 Ingersoll Rand All Rights Reserved
TAG: _________________________________
15 SERIES
Multi Zone Mini-SplitInverter System
M4THM1542A15NA
M4THM1542A-SUB-1B-EN
Specifications
M4THM1542A15NA
208 / 230 / 1 60Hz
M4THM1542A15NA40000
8530 - 4640044500
10660 - 477502480017600
15.0 / 8.29.1
Inverter Rotary60
19.073010EEV
0 ~ 118 5 ~ 75Aluminum Fin-Copper Tube
5/162 - 0.055
40.2 x 1.5 x 41.6860 / 650 / 550
1401.150
323722.4
Automatic Defrosting6858
42.8 x 17.3 x 43.445.6 x 19.4 x 48.6
224.9 / 247169.3429.050.0
1/43/81/43/81/41/21/41/23/85/85080230
MODEL - Heat Pump Only
RATED Volts/PHFrequency (Hz)
Outdoor UnitRated Cooling Capacity Cooling Capacity Range (Btu/h)Rated Heating CapacityHeating Capacity Range @ 47 F (Btu/h)Max. Heating Capacity @ 17 F (Btu/h)Max Heating Capacity @ 5 F (Btu/h)SEER / HSPFEERCompressor TypeL.R.A. (A)Compressor RLA(A)Compressor Power Input(W)Throttling MethodWorking Temp Range (°F) Cooling/HeatingCondenserPipe Diameter (inch)Row Fin Gap (inch)Coil length (L) x height (H) x coil width (W) (inch)Fan Motor Speed (rpm)Output of Fan Motor (W)Fan Motor RLA (A)Fuse (A)Air Flow Volume of Outdoor Unit (CFM)Fan Diameter (inch)Defrosting MethodSound Power Level dB (A)Sound PRESSURE Level dB (A)1Uncrated Dimension (W/D/H) (inch)Crated Dimension of Package (L/W/H) (inch)Net Weight /Gross Weight (lbs)Refrigerant Charge (oz)MCAM.O.P
Connection PipeOuter Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Outer Diameter Liquid Pipe (inch)Outer Diameter Gas Pipe (inch)Max Height Distance (ft)Max Length Distance (ft) - Single Unit EachMax Length Distance (ft) - Multiple Units Total
1 Sound PRESSURE Level @ 3.3 ft. dB(A)
40.0
42.8
24.8
17.3
14.3
15.8
43.4
42K Unit
Unit: Feet
M4THM1518 M4THM1524 M4THM1530 M4THM1536 M4THM1542
Maximum total length 75 230 230 230 260
Maximum length to single IDU 33 65 65 65 80
Minimum distance to single IDU 10 10 10 10 10
Maximum ODU/IDU height difference 16 33 33 50 50
Maximum IDU/IDU height difference 16 25 25 25 25
Maximum w/o adding charge 66 100 130 130 165
Minimum w/o removing charge 33 50 65 80 100
Amount of R410-A +/- (oz/ft) 0.22 0.22 0.22 0.24 0.24
NOTES:• The refrigerant charge mentioned in the technical data does not include additional charge required
for the indoor unit(s) and the refrigerant pipe. • The amount of the additional refrigerant charge depends on the length of the liquid refrigerant pipe
installed and the number of indoor units connected. • Record the additional refrigerant charge for future maintenance.
Calculation of the Additional Refrigerant Charge:
Ductless Multi-Zone Approved Combinations
Ductless Multi-Zone Quick ReferenceMulti-Zone Heat Pumps Outdoor
18,000 BTUH 24,000 BTUH 30,000 BTUH 36,000 BTUH 42,000 BTUH
M4THM1518A12N M4THM1524A13N M4THM1530A14N M4THM1536A14N M4THM1542A15N
Multi-Zone Heat Pumps Indoor Options
9,000 BTUH 12,000 BTUH 18,000 BTUH 24,000 BTUH
High-Wall Mounted M4MHW1509A1N M4MHW1512A1N M4MHW1518A1N M4MHW1524A1N
Indoor Unit Combinations with Associated Nominal Capacity (kBTUH)
Outdoor Unit One Unit Two Units
M4THM1518A12N
18,000 BTUH
9 9+9 12+12
12 9+12
Outdoor Unit Two Units Three Units
M4THM1524A13N
24,000 BTUH
9+9 9+12 9+9+9 9+12+12 12+12+12
9+18 12+12 9+9+12 9+9+18
12+18 18+18
Outdoor Unit Two Units Three Units Four Units
M4THM1530A14N
30,000 BTUH
9+9 9+12 9+9+9 9+9+12 9+9+18 9+9+9+9 9+9+9+12 9+9+12+12
9+18 12+12 9+12+12 9+12+18 12+12+12
12+18 18+18 12+12+18
Outdoor Unit Two Units Three Units Four Units
M4THM1536A14N
36,000 BTUH
9+9 12+18 9+9+9 9+12+18 12+12+18 9+9+9+9 9+9+12+18
9+12 12+24 9+9+12 9+12+24 12+12+24 9+9+9+12 9+9+18+18
9+18 18+18 9+9+18 9+18+18 12+18+18 9+9+9+18 9+12+12+12
9+24 18+24 9+9+24 9+18+24 18+18+18 9+9+9+24 9+12+12+18
12+12 24+24 9+12+12 12+12+12 9+9+12+12 12+12+12+12
Outdoor Unit Two Units Three Units Four Units Five Units
M4THM1542A15N
42,000 BTUH
9+9 12+18 9+9+9 9+12+24 12+12+24 9+9+9+9 9+9+12+24 9+12+18+18 9+9+9+9+9 9+9+9+18+18
9+12 12+24 9+9+12 9+18+18 12+18+18 9+9+9+12 9+9+18+18 9+18+18+18 9+9+9+9+12 9+9+12+12+12
9+18 18+18 9+9+18 9+18+24 12+18+24 9+9+9+18 9+9+18+24 12+12+12+12 9+9+9+9+18 9+9+12+12+18
9+24 18+24 9+9+24 9+24+24 12+24+24 9+9+9+24 9+12+12+12 12+12+12+18 9+9+9+9+24 9+12+12+12+12
12+12 24+24 9+12+12 12+12+12 18+18+18 9+9+12+12 9+12+12+18 12+12+12+24 9+9+9+12+12 9+12+12+12+18
9+12+18 12+12+18 18+18+24 9+9+12+18 9+12+12+24 12+12+18+18 9+9+9+12+18 12+12+12+12+12
PERFORMANCE DATA
TC* SHC** TC SHC TC SHC TC SHC65 32100 25200 34100 26800 36200 28400 38900 3050070 31400 24700 33400 26200 35900 28100 38500 3020075 30700 24100 32600 25600 35500 27800 38000 2980080 30200 23700 32100 25200 35100 27500 37600 2950085 29800 23400 31800 24900 34700 27200 37200 2910090 29400 23100 31400 24600 34300 26900 37100 2910095 29000 22700 31000 24300 33900 26600 37000 29100100 28400 22300 30400 23900 33700 26400 36500 28600105 27800 21800 29900 23400 33400 26200 36000 28200110 27400 21500 29500 23100 33000 25900 35600 27900115 27000 21200 29100 22800 32600 25600 35200 27600
TC* TC TC TC0 34200 33700 33000 323005 36700 36100 35400 3460010 37900 37300 36600 3580015 38800 38200 37500 3670020 39600 39000 38300 3750025 40000 39400 38800 3810030 40500 39900 39300 3860035 41000 40500 39900 3920040 41700 41200 40600 3990045 43900 43200 42400 4150050 45300 44500 43600 4260055 45900 45100 44200 4320060 46600 45700 44800 43800
M4THM1542A1 ‐ Cooling Mode Performance Data
80°F 82°F
M4THM1542A1 ‐ Heating Mode Performance Data
*Total Capacity **Sensible Heat Capacity
*Total Capacity
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature (Dry Bulb/Wet Bulb)
Outdoor Ambient Air Temperature
(°F)
Indoor Entering Air Temperature
68/57°F 73/61°F 80/67°F 82/68°F
68°F 73°F
The manufacturer has a policy of continuous product and product data improvement and it reserves the right
to change design and specifications without notice.
Mechanical Specifications
Multi-Zone Outdoor Unit
General
This unit comes pre-charged with refriger-ant from the factory. It is designed to operate at outdoor ambient temperatures as high as 118°F. Cooling capacities with its associated indoor units shown in the catalog are AHRI certified. It is also ETL listed for outdoor ap-plication.
Unit Casing
The unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint.
Refrigerant Controls
Refrigeration system controls include a condenser fan and compressor relay. High and low pressure controls are inher-ent to the compressor. A suction line multi function service valve is standard
Compressor
The compressor features internal over temperature and over pressure protec-tion; it also has dipped hermetic motor windings. Other features include: a centrifugal oil pump and low vibration and noise.
Condenser Coil
The coil consists of aluminum finned coils brazed to copper tubing. It provides air flow resistance, efficient heat transfer, and is protected by the casing.
Low Ambient Cooling
Matched ductless products have a cooling capability to 0° F.
01/18
Optional Equipment
Optional outdoor unit accessories M4THM15Model Multi-ZoneNumber Description up to 15 SEERTAYREFLN050 ....................... Lineset Kit 1/4x3/8 - 25' .................................................................. ✔
TAYREFLN055 ....................... Lineset Kit 1/4x3/8 - 35' .................................................................. ✔
TAYREFLN060 ....................... Lineset Kit 1/4x3/8 - 50' .................................................................. ✔
TAYREFLN560 ....................... Lineset Kit 1/4x1/2 - 25' .................................................................. ✔
TAYREFLN565 ....................... Lineset Kit 1/4x1/2 - 35' .................................................................. ✔
TAYREFLN570 ....................... Lineset Kit 1/4x1/2 - 50' .................................................................. ✔
TAYREFLN155 ....................... Lineset Kit 1/4x5/8 - 25' .................................................................. ✔
TAYREFLN160 ....................... Lineset Kit 1/4x5/8 - 35' .................................................................. ✔
TAYREFLN165 ....................... Lineset Kit 1/4x5/8 - 50' .................................................................. ✔