Taewoong-TTS-Sell-Sheet

2
Preloaded in a 3.47mm (10.5Fr) delivery system Allows easy and simple deployment through the channel, under direct visualization The best solution for tight, narrow or tortuous anatomy Features Through the Scope (TTS) Esophageal Stent Specialty Endoscopic Products 200 Grandview Avenue Camp Hill, PA 17011 800.451.5797 717.761.0216 fax [email protected] gi-supply.com

Transcript of Taewoong-TTS-Sell-Sheet

Page 1: Taewoong-TTS-Sell-Sheet

� Preloaded in a 3.47mm (10.5Fr) delivery system

� Allows easy and simple deploymentthrough the channel,under direct visualization

� The best solution for tight, narrow ortortuous anatomy

Features

Through the Scope (TTS)

Esophageal StentSp

ecia

lty

End

osc

op

ic P

rod

uct

s

200 Grandview AvenueCamp Hill, PA 17011

800.451.5797717.761.0216 fax

[email protected]

Page 2: Taewoong-TTS-Sell-Sheet

Ordering Information

Part No.Stent

Diameter(A)

OverallStent Length

(C)Diameter(3.47mm)

UsableLength

Introducer System

G-EST1806F

G-EST1808F

G-EST1810F

G-EST1812F

G-EST1814F

G-EST1815F

G-EST2006F

G-EST2008F

G-EST2010F

G-EST2012F

G-EST2014F

G-EST2015F

18 mm

18 mm

18 mm

18 mm

18 mm

18 mm

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Stent FlangeDiameter

(B)

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

60 mm

80 mm

100 mm

120 mm

140 mm

150 mm

60 mm

80 mm

100 mm

120 mm

140 mm

150 mm

FunctionalStent Length

(D)

30 mm

50 mm

70 mm

90 mm

110 mm

120 mm

30 mm

50 mm

70 mm

90 mm

110 mm

120 mm

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

Tight and narrow stricture

TTS Esophageal stent passingthrough the narrow stricture

� Dr. Giorgio Battaglia, Italy

Easy and SimpleStenting Throughthe Scope Channel

200 Grandview AvenueCamp Hill, PA 17011Toll Free: 800.451.5797Fax: 717.761.0216 Email: [email protected]: gi-supply.com

© 2014 GI SupplyG-1203-00

Clinical ReferenceSung Jun Choi, Jin Hong Kim MD. Fully covered, retrievable self-expandingmetal stents (Niti-S) in palliation of malignantdysphagia: Long-term results of a prospectivestudy. Scandinavian Journal of Gastroenterology, 2011; 46: 875-880

Esophageal Fully Covered Stent

Part No.Stent

Diameter(A)

OverallStent Length

(C)Diameter(3.47mm)

UsableLength

Introducer System

G-EST1806B

G-EST1808B

G-EST1810B

G-EST1812B

G-EST1814B

G-EST1815B

G-EST2006B

G-EST2008B

G-EST2010B

G-EST2012B

G-EST2014B

G-EST2015B

18 mm

18 mm

18 mm

18 mm

18 mm

18 mm

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Stent FlangeDiameter

(B)

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

26 mm

60 mm

80 mm

100 mm

120 mm

140 mm

150 mm

60 mm

80 mm

100 mm

120 mm

140 mm

150 mm

FunctionalStent Length

(D)

30 mm

50 mm

70 mm

90 mm

110 mm

120 mm

30 mm

50 mm

70 mm

90 mm

110 mm

120 mm

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

10.5 Fr

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

180 cm

Esophageal Partially Covered Stent

Length (C)

Functional length (D)

Diameter(A)

FlangeDiameter

(B)

An ISO 13485 Registered Company