T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO...

1

Transcript of T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO...

Page 1: T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO ...summitgc.net/wp-content/uploads/2020/02/Revision-1-Walker-LA-03-04-20.pdf6. all materials indicated are new, unless specifically

12 S

unne

n Dr

ive,

Sui

te 1

00, S

t. Lo

uis,

MO

631

43T:

314

.821

.110

0

DFDF

DDD

FFF

DFDF

DFDF

DDD

FFF

DFDF

DFDF

DDD

FFF

DFDF

DFDF

DDD

FFF

DFDF

AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
CS1
AutoCAD SHX Text
NOTES AND LEGEND
AutoCAD SHX Text
RESPONSIBILITY CHART AND KEY PLAN
AutoCAD SHX Text
RBM
AutoCAD SHX Text
TAW
AutoCAD SHX Text
TAW
AutoCAD SHX Text
project
AutoCAD SHX Text
drawing
AutoCAD SHX Text
project
AutoCAD SHX Text
date
AutoCAD SHX Text
designed
AutoCAD SHX Text
drawn
AutoCAD SHX Text
checked
AutoCAD SHX Text
mark
AutoCAD SHX Text
revisions
AutoCAD SHX Text
date
AutoCAD SHX Text
by
AutoCAD SHX Text
description
AutoCAD SHX Text
PHONE: 314-821-1100
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
28050 WALKER ROAD SOUTH, WALKER, LA 70785
AutoCAD SHX Text
520574
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
PROFESSIONAL OF RECORD
AutoCAD SHX Text
CASCO DIVERSIFIED CORPORATION ARCHITECTURAL FIRM LICENSE #AE0220 EXPIRES 6/30/20
AutoCAD SHX Text
DOLLAR TREE EXPANSION
AutoCAD SHX Text
EXISTING DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA 28050 WALKER ROAD 28050 WALKER ROAD WALKER, LA 70785 DEAL # 11989 STORE # 02433
AutoCAD SHX Text
NO SECURITY MEASURE NECESSARY
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
L
AutoCAD SHX Text
ACT ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE ADA AMERICAN DISABILITIES ACT AMERICAN DISABILITIES ACT AFC ABOVE FINISHED CEILING ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR ARCH ARCHITECT,ARCHITECTURAL ARCHITECT,ARCHITECTURAL APPROX APPROXIMATE APPROXIMATE BD BOARD BOARD BLDG BUILDING BUILDING CLG CEILING CEILING CLR CLEAR CLEAR CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT COL COLUMN COLUMN DF DRINKING FOUNTAIN DRINKING FOUNTAIN DTL DETAIL DETAIL DWG DRAWING DRAWING EA EACH EACH EIFS EXTERIOR INSULATION FINISH EXTERIOR INSULATION FINISH SYSTEM ELEV ELEVATION ELEVATION EQ EQUAL EQUAL WXIST EXISTING EXISTING EXITING EXTINGUISHER EXTINGUISHER FE FIRE EXTINGUISHER FIRE EXTINGUISHER FR FIRE RETARDANT FIRE RETARDANT FRP FIBERGLASS REINFORCED PANEL FIBERGLASS REINFORCED PANEL FIN FINISH, FINISHED FINISH, FINISHED FT FOOT, FEET FOOT, FEET FTG FOOTING FOOTING FV FIELD VERIFY FIELD VERIFY GA GAGE GAGE GWB GYPSUM WALL BOARD GYPSUM WALL BOARD H HIGH HIGH HDW HARDWARE HARDWARE HM HOLLOW METAL HOLLOW METAL HGT HEIGHT HEIGHT HOL HOLLOW HOLLOW HORIZ HORIZONTALLY HORIZONTALLY HR HOUR HOUR HVAC HEATING, VENTILATION AND AIR HEATING, VENTILATION AND AIR CONDITIONING JT JOINT JOINT L LENGTH, LONG LENGTH, LONG LAM LAMINATE LAMINATE LVT LUXURY VINYL TILE LUXURY VINYL TILE MAX MAXIMUM MAXIMUM MFG, MANUF MANUFACTURE, MANUFACTURER MANUFACTURE, MANUFACTURER MIN MINIMUM, MINUTE MINIMUM, MINUTE MTD MOUNTED MOUNTED MTL METAL METAL NIC NOT IN CONTRACT NOT IN CONTRACT OC ON CENTER ON CENTER OPP OPPOSITE OPPOSITE PEJ PREFORMED EXPANSION JOINT PREFORMED EXPANSION JOINT PLAM PLASTIC LAMINATE PLASTIC LAMINATE PLYWD PLYWOOD PLYWOOD PR PAIR PAIR PSI POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH PTD PAINTED PAINTED RELO RELOCATE RELOCATE REQD REQUIRED REQUIRED SC SOLID CORE SOLID CORE SF SQUARE FEET SQUARE FEET SHT SHEET SHEET SIM SIMILAR SIMILAR STRUCT STRUCTURAL STRUCTURAL T THICK, THICKNESS THICK, THICKNESS TG TEMPERED GLASS TEMPERED GLASS THRESH THRESHOLD THRESHOLD TYP TYPICAL TYPICAL UL UNDERWRITERS LABORATORIES UNDERWRITERS LABORATORIES UON UNLESS OTHERWISE NOTED UNLESS OTHERWISE NOTED VCT VINYL COMPOSITION TILE VINYL COMPOSITION TILE VTR VENT THROUGH ROOF VENT THROUGH ROOF W WIDE, WIDTH WIDE, WIDTH WD WOOD WOOD W/ WITH WITH WWF WELDED WIRE FABRIC WELDED WIRE FABRIC & AND AND ANGLE @ A A C CENTER LINE CENTER LINE ° DEGREES , DIA DIAMETER # NUMBER NUMBER ± PLUS OR MINUS
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
XXX
AutoCAD SHX Text
X
AutoCAD SHX Text
AX
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
AX
AutoCAD SHX Text
X
AutoCAD SHX Text
AX
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
ELEVATION MARKER
AutoCAD SHX Text
ENLARGED DETAIL INDICATOR
AutoCAD SHX Text
WALL SECTION MARKER
AutoCAD SHX Text
INTERIOR ELEVATION MARKER
AutoCAD SHX Text
DEMOLITION NOTE
AutoCAD SHX Text
WALL CONSTRUCTION TYPE
AutoCAD SHX Text
REVISION MARKER
AutoCAD SHX Text
DOOR NUMBER
AutoCAD SHX Text
ELEVATION DATUM
AutoCAD SHX Text
BREAK LINE
AutoCAD SHX Text
EXISTING DOOR
AutoCAD SHX Text
NEW DOOR
AutoCAD SHX Text
GYPSUM WALL BOARD
AutoCAD SHX Text
WOOD TRIM
AutoCAD SHX Text
NEW WALL CONSTRUCTION
AutoCAD SHX Text
CMU
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
DRAWING INDEX AND DATES
AutoCAD SHX Text
PERMIT/BID
AutoCAD SHX Text
CS1 NOTES AND LEGEND, RESPONSIBILITY CHART AND KEY PLAN NOTES AND LEGEND, RESPONSIBILITY CHART AND KEY PLAN CS2 NOTES AND ACCESSIBILITY DETAILS NOTES AND ACCESSIBILITY DETAILS D1 DEMOLITION FLOOR PLAN & NOTES DEMOLITION FLOOR PLAN & NOTES D2 DEMOLITION CEILING PLAN & NOTES DEMOLITION CEILING PLAN & NOTES A1 FLOOR PLAN, WALL CONSTRUCTION TYPES AND ENLARGED OFFICE, TOILET PLANS FLOOR PLAN, WALL CONSTRUCTION TYPES AND ENLARGED OFFICE, TOILET PLANS A2 REFLECTED CEILING PLAN, LEGEND & NOTES, OFFICE ELEVATIONS & TOILET ELEVATIONS REFLECTED CEILING PLAN, LEGEND & NOTES, OFFICE ELEVATIONS & TOILET ELEVATIONS A3 EXTERIOR ELEVATION & INTERIOR ELEVATIONS EXTERIOR ELEVATION & INTERIOR ELEVATIONS A4 DETAILS, SECTIONS & SCHEDULES DETAILS, SECTIONS & SCHEDULES A4.1 DETAILS & SECTIONS DETAILS & SECTIONS A4.2 DETAILS & SECTIONS DETAILS & SECTIONS E1 ELECTRICAL POWER PLAN ELECTRICAL POWER PLAN E2 ELECTRICAL LIGHTING PLAN ELECTRICAL LIGHTING PLAN E3 ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE ELECTRICAL RISER DIAGRAM AND PANEL SCHEDULE E4 ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS MP1 FLOOR PLAN HVAC/PLUMBING FLOOR PLAN HVAC/PLUMBING MP2 SCHEDULES AND DETAILS HVAC/PLUMBING SCHEDULES AND DETAILS HVAC/PLUMBING MP3 SPECIFICATIONS HVAC/PLUMBING SPECIFICATIONS HVAC/PLUMBING FP1 FIRE PROTECTION PLANS FIRE PROTECTION PLANS FP2 FIRE PROTECTION NOTES, DETAILS, AND SPECIFICATIONSFIRE PROTECTION NOTES, DETAILS, AND SPECIFICATIONS
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
2
AutoCAD SHX Text
R
AutoCAD SHX Text
3
AutoCAD SHX Text
R
AutoCAD SHX Text
4
AutoCAD SHX Text
R
AutoCAD SHX Text
5
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
DS1 REACH-IN DETAILS & SPECIFICATIONS REACH-IN DETAILS & SPECIFICATIONS DS2 WALK-IN DETAILS & SPECIFICATIONS WALK-IN DETAILS & SPECIFICATIONS DS3 WALK-IN SPECIFICATIONS WALK-IN SPECIFICATIONS EM1 ENERGY MANAGEMENT DRAWINGS ENERGY MANAGEMENT DRAWINGS EM2 ENERGY MANAGEMENT DRAWINGS ENERGY MANAGEMENT DRAWINGS EM3 ENERGY MANAGEMENT DRAWINGS ENERGY MANAGEMENT DRAWINGS EM4 ENERGY MANAGEMENT DRAWINGSENERGY MANAGEMENT DRAWINGS
AutoCAD SHX Text
FOR REFERENCE ONLY
AutoCAD SHX Text
R
AutoCAD SHX Text
6
AutoCAD SHX Text
R
AutoCAD SHX Text
7
AutoCAD SHX Text
R
AutoCAD SHX Text
8
AutoCAD SHX Text
PROJECT DIRECTORY
AutoCAD SHX Text
PROJECT MANAGERS: CASCO : CASCO CASCO 12 SUNNEN DRIVE, SUITE 100 ST. LOUIS, MO 63143 PHONE: (314) 821-1100 FAX: (314) 821-4162 CONTACT: BOB McLAUGHLIN EMAIL: [email protected]
AutoCAD SHX Text
BUILDING DEPARTMENT: CITY OF WALKER MUNICIPAL BUILDING : CITY OF WALKER MUNICIPAL BUILDING CITY OF WALKER MUNICIPAL BUILDING 10136 FLORIDA BLVD. WALKER, LA 70785 PHONE: 225-665-8893 ALT. PHONE: 225-665-4356 CONTACT: NANCY KIMBLE
AutoCAD SHX Text
LANDLORD: MAESTRI-MURRELL, INC. : MAESTRI-MURRELL, INC. MAESTRI-MURRELL, INC. 9018 JEFFERSON HIGHWAY BATON ROUGE, LA 70809 PHONE: 225-276-6380 EMAIL:[email protected] CONTACT:JONATHAN WALKER
AutoCAD SHX Text
BUILDING CODE SUMMARY
AutoCAD SHX Text
APPLICABLE BUILDING CODE: INTERNATIONAL BUILDING CODE, 2015 EDITION INTERNATIONAL BUILDING CODE, 2015 EDITION APPLICABLE PLUMBING CODE: INTERNATIONAL PLUMBING CODE, 2015 EDITION INTERNATIONAL PLUMBING CODE, 2015 EDITION APPLICABLE MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE, 2015 EDITION INTERNATIONAL MECHANICAL CODE, 2015 EDITION APPLICABLE ELECTRICAL CODE: NATIONAL ELECTRICAL CODE, 2014 EDITION NATIONAL ELECTRICAL CODE, 2014 EDITION APPLICABLE FIRE CODE: INTERNATIONAL FIRE CODE, 2015 EDITION INTERNATIONAL FIRE CODE, 2015 EDITION APPLICABLE ENERGY CODE: IECC, 2015 EDITION IECC, 2015 EDITION APPLICABLE ACCESSIBILITY CODE: ICC/ANSI, A117.1, CURRENT EDITION ICC/ANSI, A117.1, CURRENT EDITION TYPE OF CONSTRUCTION: TYPE II B TYPE II B USE GROUP: M - MERCANTILE M - MERCANTILE NUMBER OF STORIES: ONE (1) ONE (1) SPRINKLERED: YES YES FIRE MONITORING REQUIRED: YES / WILL USE AS CURRENTLY CONFIGUREDYES / WILL USE AS CURRENTLY CONFIGURED
AutoCAD SHX Text
SCOPE OF WORK
AutoCAD SHX Text
1. TENANT FIT UP EXPANSION OF THE EXISTING DOLLAR TREE TENANT FIT UP EXPANSION OF THE EXISTING DOLLAR TREE 2. EXISTING SERVICE WITH TWO (2) EXISTING PANELS AND TWO (2) EXISTING SERVICE WITH TWO (2) EXISTING PANELS AND TWO (2) NEW PANELS. 3. ADDING NEW EMS SYSTEM. ADDING NEW EMS SYSTEM. 4. INSTALLING NEW WALK-IN FREEZER/COOLER AND NEW REACH-IN INSTALLING NEW WALK-IN FREEZER/COOLER AND NEW REACH-IN FREEZER/COOLERS. 5. BUILDING NEW OFFICE IN SALES AREA & EMPLOYEE AREA IN BUILDING NEW OFFICE IN SALES AREA & EMPLOYEE AREA IN STOCKROOM. 6. FOUR (4) NEW CONDENSING UNITS AND TWO (2) EXISTING UNITS TO FOUR (4) NEW CONDENSING UNITS AND TWO (2) EXISTING UNITS TO REMAIN ON GROUND. 7. REMOVING FIVE (5) EXISTING AIR HANDLER UNITS AND REPLACING REMOVING FIVE (5) EXISTING AIR HANDLER UNITS AND REPLACING WITH SIX (6) NEW AIR HANDLING UNITS HUNG FROM UNDER SIDE OF ROOF STRUCTURE. 8. NEW MECHANICAL DUCTWORK IN EXPANSION SPACE AND RETAINING NEW MECHANICAL DUCTWORK IN EXPANSION SPACE AND RETAINING EXISTING DUCTWORK IN THE DOLLAR TREE SPACE. 9. NEW ELECTRICAL TO ALL NEW LIGHTS, RECEPTACLES, ETC. NEW ELECTRICAL TO ALL NEW LIGHTS, RECEPTACLES, ETC. 10. PAINTING WALLS. PAINTING WALLS. 11. POLISH CONCRETE FLOORS. POLISH CONCRETE FLOORS. 12. DEMOLISH ALL WALLS AND FINISHES IN THE EXPANSION SPACE. DEMOLISH ALL WALLS AND FINISHES IN THE EXPANSION SPACE. 13. ADDING NEW CHECKOUTS AND SALES FIXTURES.ADDING NEW CHECKOUTS AND SALES FIXTURES.
AutoCAD SHX Text
DEFERRED SUBMITTALS
AutoCAD SHX Text
FIRE SPRINKLER DESIGN AND ENGINEERING: IF MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM IS REQUIRED BY THE LOUISIANA STATE FIRE MARSHAL OR STATE FIRE MARSHAL. DRAWINGS SHALL BE PERMITTED UNDER A SEPARATE SUBMITTAL BY A LICENSED CONTRACTOR. DESIGN AND ENGINEERING DOCUMENTS TO BE SIGNED/SEALED BY A LICENSED FIRE PROTECTION ENGINEER IN THE PRESIDING STATE FOLLOWING LOCAL FIRE PROTECTION REQUIREMENTS.
AutoCAD SHX Text
VESTIBULE NOTE
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
1. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS. CONSTRUCTION SHALL ALSO COMPLY WITH LANDLORD'S CRITERIA (UNLESS PRECLUDED BY CODE). 2. ALL WOOD FRAMEWORK, WOOD BLOCKING AND PLYWOOD SHALL BE ALL WOOD FRAMEWORK, WOOD BLOCKING AND PLYWOOD SHALL BE FIRE RETARDANT TREATED PER CODE. 3. ALL FINISH MATERIALS SHALL MEET FLAME SPREAD AND SMOKE ALL FINISH MATERIALS SHALL MEET FLAME SPREAD AND SMOKE DEVELOPMENT RATING CLASS C (OR CLASS 3). 4. WALL CONSTRUCTION BY THE TENANT'S CONTRACTOR IS SHOWN WALL CONSTRUCTION BY THE TENANT'S CONTRACTOR IS SHOWN HATCHED. 5. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO BID TO DETERMINE THE EXTENT OF WORK. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND THE TENANT OF ANY DISCREPANCIES PRIOR TO BIDDING. 6. ALL MATERIALS INDICATED ARE NEW, UNLESS SPECIFICALLY NOTED ALL MATERIALS INDICATED ARE NEW, UNLESS SPECIFICALLY NOTED AS EXISTING, AND SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR . ITEMS INDICATED AS TENANT SUPPLIED SHALL BE INSTALLED BY THE CONTRACTOR PER TENANT'S REQUIREMENTS AND/OR MANUFACTURER'S PUBLISHED STANDARDS. 7. ALL EXISTING MATERIALS TO REMAIN WHICH ARE DAMAGED OR ALL EXISTING MATERIALS TO REMAIN WHICH ARE DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BE PATCHED OR REPAIRED TO MATCH THE EXISTING ADJACENT MATERIALS, SO THAT THE REPAIR IS IMPERCEPTIBLE. 8. DURING THE COURSE OF CONSTRUCTION, IF THE CONTRACTOR DURING THE COURSE OF CONSTRUCTION, IF THE CONTRACTOR UNCOVERS ANY CODE VIOLATION KNOWN TO HIM OR ANY DISCREPANCY WITH THE DESIGN, CONTRACTOR SHALL NOTIFY THE ARCHITECT OF SUCH IMMEDIATELY. 9. CONTRACTOR SHALL ASSEMBLE AND INSTALL MATERIALS/ PRODUCTS CONTRACTOR SHALL ASSEMBLE AND INSTALL MATERIALS/ PRODUCTS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRIAL/ASSOCIATION STANDARDS. 10. FIELD VERIFY AND/OR REPORT ASBESTOS-CONTAINING MATERIAL TO FIELD VERIFY AND/OR REPORT ASBESTOS-CONTAINING MATERIAL TO ARCHITECT AND TENANT UPON DISCOVERY. 11. SMOKE AND FIRE PARTITIONS SHALL BE CONSTRUCTED PER THE SMOKE AND FIRE PARTITIONS SHALL BE CONSTRUCTED PER THE DESIGNATED UL DESIGN AND SHALL BE EXTENDED VERTICALLY TO THE BOTTOM OF THE STRUCTURE ABOVE. PROVIDE FIRE STOPS AND SEAL ALL PIPE AND CONDUIT PENETRATIONS WITH SEALANT THAT COMPLIES WITH THE MINIMUM FIRE RATED REQUIREMENTS FOR THE PARTITION. DUCT PENETRATIONS SHALL BE PROTECTED WITH SMOKE AND/OR FIRE DAMPERS. 12. ALL INTERIOR CONCRETE SHALL BE PORTLAND CEMENT BASED TO ALL INTERIOR CONCRETE SHALL BE PORTLAND CEMENT BASED TO INCLUDE PATCHING, FLOATING/LEVELING OF FLOORS AND INFILLING. 13. FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. LETTERING SHALL BE NOT LESS THAN 3" IN HEIGHT LOCATED ABOVE AN ACCESSIBLE CEILING AND REPEATED IN INTERVALS NOT EXCEEDING 30' HORIZONTALLY ALONG THE WALL OR PARTITION. SUGGESTED WORDING SHALL BE " FIRE AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS." 14. ANY DETAIL WHICH MAY BE INCOMPLETE OR LACKING IN THE PLANS ANY DETAIL WHICH MAY BE INCOMPLETE OR LACKING IN THE PLANS OR SPECIFICATIONS SHALL NOT CONSTITUTE CLAIM FOR EXTRA COMPENSATION. SUCH DETAIL, IF REQUESTED BY THE CONTRACTOR, SHALL BE SUPPLIED BY THE ENGINEER/ARCHITECT AND SUBMITTED TO THE CONTRACTOR IN ADVANCE OF ITS REQUIREMENT ON THE JOB. THE TRUE INTENT OF THE PLANS AND SPECIFICATIONS IS TO PRODUCE A COMPLETE WORKING FACILITY AND INCOMPLETE DETAIL WILL NOT ABROGATE THIS INTENT. 15. THE CONTRACTOR SHALL PROVIDE ALL SHOP DRAWINGS (WITH THEIR THE CONTRACTOR SHALL PROVIDE ALL SHOP DRAWINGS (WITH THEIR STAMP OF APPROVAL) AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR APPROVAL BY THE ARCHITECT/ENGINEER OF RECORD.
AutoCAD SHX Text
NEW WORK NOTES
AutoCAD SHX Text
1. PROVIDE TENANT IDENTIFICATION SIGN AT REAR DOOR PROVIDE TENANT IDENTIFICATION SIGN AT REAR DOOR PER LANDLORD'S CRITERIA. 2. (4) 2A-10BC RATED FIRE EXTINGUISHERS TO BE TENANT (4) 2A-10BC RATED FIRE EXTINGUISHERS TO BE TENANT SUPPLIED. SIMILAR TO JL INDUSTRIES MODEL COSMIC 5E. LOCATE EXTINGUISHERS AS SHOWN. PROVIDE WALL BRACKETS AND MOUNT CONTROLS AT 48" AFF MAX. PROVIDE "FIRE EXTINGUISHER" SIGNS ON WALL DIRECTLY ABOVE EACH UNIT. CONTRACTOR SHALL HAVE EXTINGUISHERS INSPECTED AND TAGGED. REFER TO J/A4.1 FOR ADDITIONAL INFORMATION. 3. THE CONTRACTOR SHALL VERIFY THAT TOILET ROOM(S), THE CONTRACTOR SHALL VERIFY THAT TOILET ROOM(S), INCLUDING FIXTURES AND ACCESSORIES (BOTH EXISTING AND NEW) MEET ALL APPLICABLE LOCAL, STATE AND FEDERAL ACCESSIBILITY CODES AND LAWS. 4. PROVIDE EXTERIOR LIGHT ABOVE REAR DOOR, AS PROVIDE EXTERIOR LIGHT ABOVE REAR DOOR, AS APPROVED BY LANDLORD, IF ONE DOES NOT EXIST WITHIN 10 FEET OF REAR DOOR. 5. PAINT ALL EXPOSED SURFACE MOUNTED CONDUIT TO PAINT ALL EXPOSED SURFACE MOUNTED CONDUIT TO MATCH ADJACENT WALL COLOR (IE WHITE OR YELLOW). 6. CONTRACTOR SHALL CAULK AROUND TOP AND BOTTOM CONTRACTOR SHALL CAULK AROUND TOP AND BOTTOM EDGES OF COLUMN SURROUNDS TO AVOID INJURY. REFER TO DETAIL 4/CS2 FOR ADDITIONAL INFORMATION. 7. REPAIR AND CLEAN ALL EXISTING MATERIALS (IE REPAIR AND CLEAN ALL EXISTING MATERIALS (IE STOREFRONT FRAMING AND GLAZING, WALLS, CEILING, ETC) TO REMAIN TO A LIKE NEW CONDITION. 8. NOTIFY DOLLAR TREE'S CONSTRUCTION PM AS TO THE NOTIFY DOLLAR TREE'S CONSTRUCTION PM AS TO THE CONDITION OF EXPOSED CONCRETE BLOCK WALL TO REMAIN ON THE SALES FLOOR. DOLLAR TREE WILL MAKE THE DETERMINATION AS TO WHETHER THE WALL'S CONDITION IS SUITABLE FOR PAINTING OR NEEDS TO BE FURRED OUT WITH METAL STUDS AND GWB. 9. CONTRACTOR SHALL INSTALL TENANT SUPPLIED FIXTURES CONTRACTOR SHALL INSTALL TENANT SUPPLIED FIXTURES TO INCLUDE BUT NOT LIMITED TO CART CORRAL, PERIMETER WALL GONDOLA, FLOOR GONDOLA, BALLOON CENTER, HANGING BALLOON CORRALS, HELIUM TANK CABINET (SALES FLOOR), HELIUM TANK BRACKETS (STOCKROOM, SEE DETAIL), GRAVITY CONVEYOR SYSTEM, AND MOBILE FIXTURES PER TENANT'S FIXTURE PLAN. CALIFORNIA PROJECTS ONLY, CONTRACTOR SHALL STRAP ALL FIXTURES AS PER THE SEISMIC DRAWINGS PROVIDED. CONTACT THE CONSTRUCTION PM IF FIXTURE/SEISMIC DRAWING WAS NOT MADE AVAILABLE TO YOU DURING YOUR BIDDING PROCESS. 10. DOORS AND FRAMES (OTHER THAN THOSE LISTED AS DOORS AND FRAMES (OTHER THAN THOSE LISTED AS EXIST) ARE TENANT SUPPLIED FOR CONTRACTOR INSTALLATION. STOREFRONT DOORS (WHEN NOTED) SHALL BE SUPPLIED AND INSTALLED BY CONTRACTOR AS REQUIRED. AUTOMATIC DOORS (WHEN NOTED) WILL BE SUPPLIED AND INSTALLED BY TENANT'S VENDOR (CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL CONNECTION). 11. CONTRACTOR SHALL REMOVE ANY EXISTING SIGNAGE CONTRACTOR SHALL REMOVE ANY EXISTING SIGNAGE THAT HAS PREVIOUS TENANT'S NAME (INTERIOR AND/OR EXTERIOR) ANY SIGNAGE THAT IS REQUIRED SHALL BE REPLACED IN LIKE KIND WITH DOLLAR TREE'S NAME. 12. CONTRACTOR SHALL VERIFY IF THERE IS AN EXISTING CONTRACTOR SHALL VERIFY IF THERE IS AN EXISTING ACCESS PANEL TO TENANT'S SIGNAGE. IF ACCESS PANEL DOES NOT EXIST, INSTALL 2'-0" X 2'-0" ACCESS PANEL EITHER INSIDE AT DOLLAR TREE'S SPACE ABOVE THE CEILING (VERIFY FIRE RATINGS AND CODE REQUIREMENTS) OR IN THE EXTERIOR SOFFIT TO MATCH CANOPY CONSTRUCTION AS ALLOWED BY LANDLORD. CONFIRM WITH SIGN VENDOR FOR LOCATION PRIOR TO INSTALLING. 13. CONTRACTOR SHALL NOTIFY CONSTRUCTION PM OF ANY CONTRACTOR SHALL NOTIFY CONSTRUCTION PM OF ANY NECESSARY REPAIRS TO ROOF PRIOR TO PERFORMING ANY OR ALL WORK. 14. CONTRACTOR SHALL REMOVE AND DISPOSE OF ANY AND CONTRACTOR SHALL REMOVE AND DISPOSE OF ANY AND ALL PREVIOUS TENANT'S EXTERIOR SIGNAGE LEFT BEHIND. ALL EXISTING MATERIALS TO REMAIN WHICH ARE DAMAGED OR OTHERWISED DISTURBED BY REMOVAL OF PREVIOUS TENANT SIGNAGE SHALL BE PATCHED OR REPAIRED AND PAINTED TO MATCH EXISTING ADJACENT MATERIALS SO THAT THE REPAIR IS IMPERCEPTIBLE. CONTRACTORS SHALL NOT INCLUDE THIS SCOPE OF WORK IN THEIR BID AND WILL BE HANDLED VIA CHANGE ORDER AFTER SITE EVALUATION IS DONE BY WINNING BIDDER. CONTRACTOR SHALL FORWARD THE EVALUATION AND PRICE QUOTE TO THE CONSTRUCTION PM FOR APPROVAL PRIOR TO PERFORMING ANY AND ALL WORK. 15. CONTRACTOR SHALL INSTALL TENANT SUPPLIED INTERIOR CONTRACTOR SHALL INSTALL TENANT SUPPLIED INTERIOR GRAPHICS AND SIGNS TO INCLUDE BUT NOT LIMITED TO PERIMETER WALL GRAPHICS/SIGNAGE, HANGING GRAPHICS/SIGNAGE AND STOREFRONT WINDOW DECALS. CONTACT THE CONSTRUCTION PM FOR GRAPHIC/SIGNAGE DRAWINGS. 16. CONTRACTOR SHALL SEAL ALL EXTERIOR PENETRATIONS CONTRACTOR SHALL SEAL ALL EXTERIOR PENETRATIONS INCLUDING CRACKS, HOLES, GAPS, AND EXISTING PENETRATIONS. CONTRACTOR SHALL SELECT MATERIAL APPROPRIATE FOR CONDITION TO PROVIDE PERMANENT RODENT-PROOF INFILL (INSULATION SPRAY FOAM IS NOT AN ACCEPTABLE FINISHED MATERIAL.) 17. CONTRACTOR SHALL INSTALL NEW ENTRY "DECO RIB" CONTRACTOR SHALL INSTALL NEW ENTRY "DECO RIB" CARPET TILE W/ TRANSITION STRIP. TRANSITION STRIP TO BE SECURED TO FLOOR W/ 3/16" X 1 3/4" TAPCON SCREWS. 18. CONTRACTOR SHALL POST ON BULLETIN BOARD IN OFFICE CONTRACTOR SHALL POST ON BULLETIN BOARD IN OFFICE FINAL INSPECTIONS AND CERTIFICATE OF OCCUPANCY. 19. AT ROOF, FLASH NEW MECHANICAL EQUIPMENT CURBS IN AT ROOF, FLASH NEW MECHANICAL EQUIPMENT CURBS IN ACCORDANCE WITH ROOFING MANUFACTURER'S RECOMMENDATIONS. REFER TO MECHANICAL AND/OR STRUCTURAL DRAWINGS FOR MORE INFORMATION. GENERAL CONTRACTOR SHALL COORDINATE WITH CONSTRUCTION PM PRIOR TO STARTING WORK & TO USE LANDLORD'S ROOFING CONTRACTOR AS NOT TO VOID LANDLORD ROOF WARRANTY. 20. PROVIDE NEW ALUMINUM AND GLASS STOREFRONT SYSTEM PROVIDE NEW ALUMINUM AND GLASS STOREFRONT SYSTEM EQUAL TO KAWNEER TRIFAB VG 451 SERIES, STICK SYSTEM FABRICATION, ** CLEAR*DARK BRONZE ANODIZED FINISH. PROVIDE TEMPERED 1" INSULATED LOW E GLAZING AS INDICATED. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL FIELD CONDITIONS, AND FOR ALL ACCESSORY PARTS AND HARDWARE REQUIRED. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE LANDLORD FOR APPROVAL PRIOR TO CONSTRUCTION. 21. ALL PLAQUE SIGNAGE INCLUDING BUT NOT LIMITED TO ALL PLAQUE SIGNAGE INCLUDING BUT NOT LIMITED TO TOILET SIGNS, LADDER STORAGE SIGN, AND FLEX CONVEYOR SIGN SHALL BE ATTACHED TO MOUNTING SURFACE WITH CONSTRUCTION ADHESIVE.
AutoCAD SHX Text
GENERAL SITE
AutoCAD SHX Text
1.IN ACCORDANCE WITH CHAPTER 11, ACCESSIBILITY - SECTIONS IN ACCORDANCE WITH CHAPTER 11, ACCESSIBILITY - SECTIONS 1104 AND 1106 OF THE INTERNATIONAL BUILDING CODE, 2015 EDITION, THE EXTERIOR ROUTES OF TRAVEL AND ACCESSIBLE PARKING ARE EXISTING PRIOR TO THE OCCUPANCY OF THE NEW TENANT. NO CHANGE OF OCCUPANCY OR EXTERIOR SITE MODIFICATION SHALL OCCUR WITHOUT PRIOR PERMITTING AND COMPLIANCE TO ABOVE MENTIONED CODE. REQUIRED SITE DEVELOPMENT OR COMPLIANCE TO ABOVE MENTIONED CODE SHALL BE SOLE RESPONSIBILITY OF LANDLORD AND/OR OWNER OF EXISTING BUILDING AND SITE.
AutoCAD SHX Text
ACCESSIBILITY NOTES
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
"LOW/MEDIUM SECURITY"
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
EXPIRES 12/31/20
AutoCAD SHX Text
LIC. # 9222
AutoCAD SHX Text
KRISTEN M. MACK
AutoCAD SHX Text
STORE # ____________ ____________ TURNOVER DATE: ____________ ____________ OPEN DATE: ____________ ____________ CONTRACTOR: ____________ ____________ SVN / TVN / AS-IS / SHELL / MALL / RELOCATION / EXPANSION
AutoCAD SHX Text
A VESTIBULE IS NOT INCLUDED ON THIS PROJECT BASED ON THE 2015 IECC, PARAGRAPH 502.4.7 VESTIBULES, EXCEPTION 1. EXCEPTION 1 ALLOWS FOR OMISSION OF VESTIBULES FOR COMMERCIAL BUILDINGS IN CLIMATE ZONES 1 AND 2 AS INDICATED IN FIGURE 301.1 AND TABLE 301.1.
AutoCAD SHX Text
STATE FIRE MARSHAL: LOUISIANA STATE FIRE MARSHAL : LOUISIANA STATE FIRE MARSHAL LOUISIANA STATE FIRE MARSHAL LOUISIANA STATE FIRE MARSHAL 8181 INDEPENDENCE BLVD BATON ROUGE, LA 70806 PHONE: (225) 925-4911
AutoCAD SHX Text
CONSTRUCTION CLARK, GEER, LATHAM & ASSOC., INC CLARK, GEER, LATHAM & ASSOC., INC OBSERVATION (ARCH): 3901 SPRINGHILL AVE. 3901 SPRINGHILL AVE. MOBILE, ALABAMA 36608 PHONE: (251) 344-7073 FAX: (251) 343-9179 CONTACT: THOMAS LATHAM
AutoCAD SHX Text
TENANT: DOLLAR TREE / FAMILY DOLLAR : DOLLAR TREE / FAMILY DOLLAR DOLLAR TREE / FAMILY DOLLAR 500 VOLVO PARKWAY CHESAPEAKE, VIRGINIA 23320 PHONE: (412) 335-7406 FAX: (757) 321-5300 (757) 321-5300 CONTACT: JAMES RODAK EMAIL: [email protected]
AutoCAD SHX Text
SIGN CONTRACTOR: ANCHOR SIGNS : ANCHOR SIGNS ANCHOR SIGNS 2200 DISCHER AVE. CHARLESTON, SC 29405 PHONE: (800) 213-3331 EMAIL: [email protected] CONTACT: TOM CARR
AutoCAD SHX Text
FREEZER/COOLER VENDOR: ORIGIN RETAIL SOLUTIONS : ORIGIN RETAIL SOLUTIONS ORIGIN RETAIL SOLUTIONS 12220 BIRMINGHAM HIGHWAY BUILDING 90 MILTON, GA 30004 PHONE: (770) 374-9362 CONTACT: TONY O'CONNOR
AutoCAD SHX Text
VERA McGOWAN
AutoCAD SHX Text
HARTMAN LANE
AutoCAD SHX Text
WALKER SOUTH RD.
AutoCAD SHX Text
OLD WALKER S
AutoCAD SHX Text
LaQUINTA INN & SUITES
AutoCAD SHX Text
WAFFLE HOUSE
AutoCAD SHX Text
WHOLLY GROUND CHURCH & COFFEE SHOP
AutoCAD SHX Text
BIG BAD BEN CAR WASH
AutoCAD SHX Text
EXPANSION OF EXISTING STORE
AutoCAD SHX Text
CLARIFICATIONS
AutoCAD SHX Text
03/04/20
Page 2: T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO ...summitgc.net/wp-content/uploads/2020/02/Revision-1-Walker-LA-03-04-20.pdf6. all materials indicated are new, unless specifically

12 S

unne

n Dr

ive,

Sui

te 1

00, S

t. Lo

uis,

MO

631

43T:

314

.821

.110

0

AutoCAD SHX Text
D1
AutoCAD SHX Text
DEMOLITION NOTES
AutoCAD SHX Text
DEMOLITION FLOOR PLAN AND
AutoCAD SHX Text
RBM
AutoCAD SHX Text
TAW
AutoCAD SHX Text
TAW
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DEMOLITION FLOOR PLAN
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
GENERAL DEMOLITION NOTES
AutoCAD SHX Text
DEMOLITION KEY NOTES
AutoCAD SHX Text
project
AutoCAD SHX Text
drawing
AutoCAD SHX Text
project
AutoCAD SHX Text
date
AutoCAD SHX Text
designed
AutoCAD SHX Text
drawn
AutoCAD SHX Text
checked
AutoCAD SHX Text
mark
AutoCAD SHX Text
revisions
AutoCAD SHX Text
date
AutoCAD SHX Text
by
AutoCAD SHX Text
description
AutoCAD SHX Text
PHONE: 314-821-1100
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
28050 WALKER ROAD SOUTH, WALKER, LA 70785
AutoCAD SHX Text
520574
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
PROFESSIONAL OF RECORD
AutoCAD SHX Text
CASCO DIVERSIFIED CORPORATION ARCHITECTURAL FIRM LICENSE #AE0220 EXPIRES 6/30/20
AutoCAD SHX Text
9
AutoCAD SHX Text
8
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
DEMOLISH ALL RESTROOM FIXTURES AND ACCESSORIES COMPLETE. CAP ALL UNUSED STUB-UPS 6" BELOW CONC. FLOOR. PATCH AND REPAIR CONCRETE SLAB AS REQUIRED.
AutoCAD SHX Text
REMOVE ANY ITEMS ATTACHED TO PERIMETER WALLS, KNEE WALL(S), & FURRED COLUMNS. EXISTING PERIMETER FURRING AND GYP. BD. SHALL REMAIN. REPAIR & RESTORE TO LIKE NEW CONDITION PREPARE FOR APPLICATION OF NEW FINISHES.
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
1
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
5
AutoCAD SHX Text
7
AutoCAD SHX Text
4
AutoCAD SHX Text
EXISTING TOILET ROOMS, FIXTURES AND FLOOR DRAINS TO REMAIN. G.C. TO VERIFY TOILET ROOMS MEET ALL LOCAL CODES AND REPAIR/REPLACE TOILET FIXTURES AND ACCESSORIES AS REQUIRED.
AutoCAD SHX Text
DEMOLISH EXISTING MTL. STUD AND GWB PARTITIONS COMPLETE (SHOWN DASHED, TYP.) VERIFY THAT THESE WALLS ARE NOT BEARING WALLS PRIOR TO DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY.
AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
REMOVE EXISTING WALL FIXTURES AND FINISHES COMPLETE.
AutoCAD SHX Text
FLOORING CONTRACTOR (TENANT HIRED) SHALL REMOVE EXISTING CARPET COMPLETE. GC SHALL NOT INCLUDE IN BID.
AutoCAD SHX Text
FLOORING CONTRACTOR (TENANT HIRED) SHALL REMOVE EXISTING VCT FLOORING COMPLETE. GC SHALL NOT INCLUDE IN BID.
AutoCAD SHX Text
FLOORING CONTRACTOR (TENANT HIRED) SHALL REMOVE EXISTING CERAMIC TILE COMPLETE. GC SHALL NOT INCLUDE IN BID.
AutoCAD SHX Text
EXISTING OFFICE, OFFICE COUNTER, SHELVING AND ACCESSORIES (INCLUDING FLOOR MOUNTED SAFE) TO REMOVED COMPLETE.
AutoCAD SHX Text
1. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE THEM SELF WITH ALL APPLICABLE CODES, RULES, PROCEDURES, OR CONSTRAINTS OF ANY KIND PRIOR TO COMMENCEMENT OF DEMOLITION INCLUDING ANY FEDERAL, STATE, CITY, MUNICIPAL, OR LANDLORD REQUIREMENTS. 2. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO KEEP IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO KEEP ORDERLY WORKING CONDITIONS WITHIN, AND AROUND THE PREMISES - REMOVE ALL DEBRIS IN THE APPROPRIATE MANNER. 3. SPACE IS TO BE BROOM CLEAN READY FOR BUILD OUT OF NEW SPACE IS TO BE BROOM CLEAN READY FOR BUILD OUT OF NEW SPACE & FINISHES. 4. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTRACTING GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTRACTING TRASH REMOVAL SERVICE. TRASH REMOVAL MUST BE COORDINATED WITH ON-SITE PROPERTY MANAGEMENT. 5. CONTRACTOR TO PROTECT DEMISING WALL FRAMING & CONTRACTOR TO PROTECT DEMISING WALL FRAMING & REPLACE ALL DAMAGED AREAS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING & CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING & PAYING FOR ALL DEMOLITION PERMITS. 7. THIS DRAWING REFLECTS AVAILABLE DEMOLITION INFORMATION, THIS DRAWING REFLECTS AVAILABLE DEMOLITION INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF ALL CONTRACTORS TO VISIT THE SITE & REVIEW ALL CONSTRUCTION DOCUMENTS TO FULLY DETERMINE THE SCOPE & INTENT OF THE DEMOLITION ACTIVITY. 8. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL SPECIFIC DEMOLITION INFORMATION & INSTRUCTION AS TO WHAT EXISTING EQUIPMENT AND/OR CONSTRUCTION IS TO REMAIN. 9. CONTRACTOR IS TO INSPECT THE PREMISES PRIOR TO CONTRACTOR IS TO INSPECT THE PREMISES PRIOR TO SUBMITTING A BID AND BE RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED FOR NEW CONSTRUCTION. 10. GENERAL CONTRACTOR IS TO PROVIDE ALL NECESSARY DUST & GENERAL CONTRACTOR IS TO PROVIDE ALL NECESSARY DUST & TRAFFIC BARRIERS & TEMPORARY PARTITIONS AS REQUIRED TO MAINTAIN A SAFE & CLEAN ENVIRONMENT FOR THE PUBLIC, EMPLOYEES, AND PROPERTY THROUGHOUT THE PROJECT. 11. ANY EXISTING MECHANICAL EQUIPMENT TO BE ABANDONED MUST ANY EXISTING MECHANICAL EQUIPMENT TO BE ABANDONED MUST BE COMPLETELY REMOVED AND PROPERLY DISPOSED OF, AND ANY REPAIRS TO THE ROOFING SYSTEMS DUE TO REMOVAL OF SAID EQUIPMENT MUST BE COMPLETED. 12. IN ALL WALLS & FIXTURES THAT ARE TO BE REMOVED, THE IN ALL WALLS & FIXTURES THAT ARE TO BE REMOVED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION OF THE SOURCE AND REMOVING OR CAPPING ANY ELECTRICAL, PLUMBING AND/ OR GAS LINES THAT ARE DISCLOSED AND NOT SCHEDULED FOR REUSE. 13. CONTRACTOR TO PATCH/REPAIR/REPLACE EXISTING FLOORS, CONTRACTOR TO PATCH/REPAIR/REPLACE EXISTING FLOORS, WALLS, AND CEILINGS TO MATCH ADJACENT CONSTRUCTION DUE TO DEMOLITION OF FIXTURES, EQUIPMENT, AND ETC. 14. THE CONTRACTOR SHALL ADHERE TO PROPER RECOVERY AND THE CONTRACTOR SHALL ADHERE TO PROPER RECOVERY AND DISPOSAL OF ALL REFRIGERANTS. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR COMPLIANCE WITH STATE AND FEDERAL REGULATIONS RELATING TO CLEAN AIR AND/OR VENTING OF CFC AND/OR HCFC REFRIGERANTS UNTIL THE EQUIPMENT IS TURNED OVER TO TENANT FOR OPERATION AND MAINTENANCE. THIS RESPONSIBILITY SHALL INCLUDE ALL WORK RELATING TO DISCHARGING ANY AND ALL HVAC REFRIGERANT SYSTEMS OF ANY EXISTING EQUIPMENT REUSED OR REMOVED. 15. G.C. SHALL PROVIDE ALL TEMPORARY SHORING, BRACING & G.C. SHALL PROVIDE ALL TEMPORARY SHORING, BRACING & PINNING OF WALLS REQUIRED TO MAINTAIN INTEGRITY OF WALL CONSTRUCTION DURING DEMOLITION & UNTIL WALL HAS BEEN COMPLETED.
AutoCAD SHX Text
EXISTING REAR EXTERIOR DOOR AND FRAME TO REMAIN.
AutoCAD SHX Text
EXISTING STOREFRONT GLAZING TO BE REMOVED COMPLETE. PREPARE OPENING FOR INSTALLATION OF NEW DOORS AND GLAZING.
AutoCAD SHX Text
EXIST. ALUM/GLASS STOREFRONT TO REMAIN.
AutoCAD SHX Text
EXISTING CONCRETE SIDEWALK TO REMAIN.
AutoCAD SHX Text
EXISTING CONCRETE ACCESSIBILITY RAMP TO REMAIN.
AutoCAD SHX Text
EXISTING ELECTRICAL EQUIPMENT TO REMAIN. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text
DEMOLISH INTERIOR DOOR AND FRAME COMPLETE
AutoCAD SHX Text
EXISTING INTERIOR WALLS TO REMAIN.
AutoCAD SHX Text
EXISTING DOOR TO REMAIN.
AutoCAD SHX Text
EXIST. BOLLARDS TO REMAIN (TYP OF 5).
AutoCAD SHX Text
1.2
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
A.9
AutoCAD SHX Text
A
AutoCAD SHX Text
CU-5
AutoCAD SHX Text
CU-4
AutoCAD SHX Text
CU-3
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
A.1
AutoCAD SHX Text
B
AutoCAD SHX Text
EXPIRES 12/31/20
AutoCAD SHX Text
LIC. # 9222
AutoCAD SHX Text
KRISTEN M. MACK
AutoCAD SHX Text
NOTE: THIS DRAWING SET IS TO BE VIEWED AS A WHOLE. ALL WORK PERTAINING TO A SPECIFIC CONTRACTOR MAY OR MAY NOT BE SHOWN ON SPECIFIC DRAWINGS SECTIONS. IT IS EACH SUBCONTRACTOR'S RESPONSIBILITY TO PREPARE THEIR BID FROM A COMPLETE SET OF CONSTRUTCTION DOCUMENTS.
AutoCAD SHX Text
EXIST. CONDENSING UNIT TO BE REMOVED COMPLETE. ALL UTILITIES TO BE REMOVED BACK TO SOURCE. PATCH AND REPAIR AREAS AS REQUIRED. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL USE LANDLORDS ROOFING CONTRACTOR SO WORK WILL NOT VOID WARRANTY.
AutoCAD SHX Text
REMOVE PORTION OF EXISTING WALL COMPLETE.
AutoCAD SHX Text
EXISTING METAL STUD DEMISING WALL TO REMAIN.
AutoCAD SHX Text
6
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
18
AutoCAD SHX Text
3
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
12
AutoCAD SHX Text
12
AutoCAD SHX Text
24
AutoCAD SHX Text
24
AutoCAD SHX Text
14
AutoCAD SHX Text
14
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
17
AutoCAD SHX Text
17
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
19
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
EXIST. CONDENSING UNITS TO REMAIN.
AutoCAD SHX Text
21
AutoCAD SHX Text
20
AutoCAD SHX Text
21
AutoCAD SHX Text
22
AutoCAD SHX Text
EXIST. SANITARY CLEAN OUT TO REMAIN.
AutoCAD SHX Text
22
AutoCAD SHX Text
23
AutoCAD SHX Text
23
AutoCAD SHX Text
EXIST. HI-LO WATER FOUNTAINS TO REMAIN.
AutoCAD SHX Text
13
AutoCAD SHX Text
EXISTING ALUM./GLASS DOORS, REMOVE EGRESS HARDWARE AND LOCK IN CLOSED POSITION. COVER HOLES AS REQUIRED.
AutoCAD SHX Text
24
AutoCAD SHX Text
25
AutoCAD SHX Text
AT EXISTING DOLLAR TREE SPACE, REMOVE ALL EXISTING GONDOLA, SHELVING, CHECKOUTS AND OTHER ACCESSORIES NOT ATTACHED TO WALLS COMPLETE.
AutoCAD SHX Text
26
AutoCAD SHX Text
26
AutoCAD SHX Text
25
AutoCAD SHX Text
27
AutoCAD SHX Text
EXIST. BLACK FILM ON INTERIOR GLAZING TO REMAIN.
AutoCAD SHX Text
28
AutoCAD SHX Text
EXIST. BLACK FILM AND GRAPHICS TO BE REMOVED COMPLETE.
AutoCAD SHX Text
27
AutoCAD SHX Text
28
AutoCAD SHX Text
29
AutoCAD SHX Text
REMOVE EXISTING TOILET COMPLETE AND REPLACE WITH NEW TOILET WITH FLUSH HANDLE ON THE CORRECT SIDE.
AutoCAD SHX Text
30
AutoCAD SHX Text
REMOVE EXISTING FRP COMPLETE TO MAKE WAY FOR NEW BLOCKING AND VERTICAL GRAB BAR. INSTALL NEW FRP.
AutoCAD SHX Text
29
AutoCAD SHX Text
31
AutoCAD SHX Text
EXISTING VCT IN RESTROOMS TO REMAIN. CLEAN AND REPAIR TO LIKE NEW CONDITIONS.
AutoCAD SHX Text
31
AutoCAD SHX Text
30
AutoCAD SHX Text
31
AutoCAD SHX Text
30
AutoCAD SHX Text
32
AutoCAD SHX Text
EXIST. BOLLARDS TO BE REMOVED COMPLETE. (TYP. OF 3)
AutoCAD SHX Text
32
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
03/04/20
AutoCAD SHX Text
TAW
AutoCAD SHX Text
CLARIFICATIONS
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
33
AutoCAD SHX Text
33
AutoCAD SHX Text
ALL EXIST. EXTERIOR GRAPHICS ON GLAZING TO BE REMOVED COMPLETE.
Page 3: T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO ...summitgc.net/wp-content/uploads/2020/02/Revision-1-Walker-LA-03-04-20.pdf6. all materials indicated are new, unless specifically

12 S

unne

n Dr

ive,

Sui

te 1

00, S

t. Lo

uis,

MO

631

43T:

314

.821

.110

0

EE

E

E

AutoCAD SHX Text
D2
AutoCAD SHX Text
AND NOTES
AutoCAD SHX Text
DEMOLITION CEILING PLAN
AutoCAD SHX Text
RBM
AutoCAD SHX Text
XXX
AutoCAD SHX Text
XXX
AutoCAD SHX Text
GENERAL DEMOLITION NOTES
AutoCAD SHX Text
DEMOLITION KEY NOTES
AutoCAD SHX Text
project
AutoCAD SHX Text
drawing
AutoCAD SHX Text
project
AutoCAD SHX Text
date
AutoCAD SHX Text
designed
AutoCAD SHX Text
drawn
AutoCAD SHX Text
checked
AutoCAD SHX Text
mark
AutoCAD SHX Text
revisions
AutoCAD SHX Text
date
AutoCAD SHX Text
by
AutoCAD SHX Text
description
AutoCAD SHX Text
PHONE: 314-821-1100
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
28050 WALKER ROAD SOUTH, WALKER, LA 70785
AutoCAD SHX Text
520574
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
PROFESSIONAL OF RECORD
AutoCAD SHX Text
CASCO DIVERSIFIED CORPORATION ARCHITECTURAL FIRM LICENSE #AE0220 EXPIRES 6/30/20
AutoCAD SHX Text
AT EXPANSION SPACE, DEMOLISH CEILING GRID, TILE, LIGHTS (BACK TO SOURCE), AND ALL OTHER RELATED CEILING ITEMS COMPLETE (I.E. DIFFUSERS, DUCTWORK, SPEAKERS, EMERG. LIGHTS, DUCTWORK, ETC.)
AutoCAD SHX Text
AT EXISITING DOLLAR TREE SPACE, ALL DUCT AND AIR DEVICES TO REMAIN. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
1.2
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
A.9
AutoCAD SHX Text
A
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text
AHU-2
AutoCAD SHX Text
AHU-3
AutoCAD SHX Text
AHU-4
AutoCAD SHX Text
AHU-5
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
A.1
AutoCAD SHX Text
B
AutoCAD SHX Text
1. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE THEM SELF WITH ALL APPLICABLE CODES, RULES, PROCEDURES, OR CONSTRAINTS OF ANY KIND PRIOR TO COMMENCEMENT OF DEMOLITION INCLUDING ANY FEDERAL, STATE, CITY, MUNICIPAL, OR LANDLORD REQUIREMENTS. 2. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO KEEP IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO KEEP ORDERLY WORKING CONDITIONS WITHIN, AND AROUND THE PREMISES - REMOVE ALL DEBRIS IN THE APPROPRIATE MANNER. 3. SPACE IS TO BE BROOM CLEAN READY FOR BUILD OUT OF NEW SPACE IS TO BE BROOM CLEAN READY FOR BUILD OUT OF NEW SPACE & FINISHES. 4. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTRACTING GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTRACTING TRASH REMOVAL SERVICE. TRASH REMOVAL MUST BE COORDINATED WITH ON-SITE PROPERTY MANAGEMENT. 5. CONTRACTOR TO PROTECT DEMISING WALL FRAMING & CONTRACTOR TO PROTECT DEMISING WALL FRAMING & REPLACE ALL DAMAGED AREAS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING & CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING & PAYING FOR ALL DEMOLITION PERMITS. 7. THIS DRAWING REFLECTS AVAILABLE DEMOLITION INFORMATION, THIS DRAWING REFLECTS AVAILABLE DEMOLITION INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF ALL CONTRACTORS TO VISIT THE SITE & REVIEW ALL CONSTRUCTION DOCUMENTS TO FULLY DETERMINE THE SCOPE & INTENT OF THE DEMOLITION ACTIVITY. 8. REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL SPECIFIC DEMOLITION INFORMATION & INSTRUCTION AS TO WHAT EXISTING EQUIPMENT AND/OR CONSTRUCTION IS TO REMAIN. 9. CONTRACTOR IS TO INSPECT THE PREMISES PRIOR TO CONTRACTOR IS TO INSPECT THE PREMISES PRIOR TO SUBMITTING A BID AND BE RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED FOR NEW CONSTRUCTION. 10. GENERAL CONTRACTOR IS TO PROVIDE ALL NECESSARY DUST & GENERAL CONTRACTOR IS TO PROVIDE ALL NECESSARY DUST & TRAFFIC BARRIERS & TEMPORARY PARTITIONS AS REQUIRED TO MAINTAIN A SAFE & CLEAN ENVIRONMENT FOR THE PUBLIC, EMPLOYEES, AND PROPERTY THROUGHOUT THE PROJECT. 11. ANY EXISTING MECHANICAL EQUIPMENT TO BE ABANDONED MUST ANY EXISTING MECHANICAL EQUIPMENT TO BE ABANDONED MUST BE COMPLETELY REMOVED AND PROPERLY DISPOSED OF, AND ANY REPAIRS TO THE ROOFING SYSTEMS DUE TO REMOVAL OF SAID EQUIPMENT MUST BE COMPLETED. 12. IN ALL WALLS & FIXTURES THAT ARE TO BE REMOVED, THE IN ALL WALLS & FIXTURES THAT ARE TO BE REMOVED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISCONNECTION OF THE SOURCE AND REMOVING OR CAPPING ANY ELECTRICAL, PLUMBING AND/ OR GAS LINES THAT ARE DISCLOSED AND NOT SCHEDULED FOR REUSE. 13. CONTRACTOR TO PATCH/REPAIR/REPLACE EXISTING FLOORS, CONTRACTOR TO PATCH/REPAIR/REPLACE EXISTING FLOORS, WALLS, AND CEILINGS TO MATCH ADJACENT CONSTRUCTION DUE TO DEMOLITION OF FIXTURES, EQUIPMENT, AND ETC. 14. THE CONTRACTOR SHALL ADHERE TO PROPER RECOVERY AND THE CONTRACTOR SHALL ADHERE TO PROPER RECOVERY AND DISPOSAL OF ALL REFRIGERANTS. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR COMPLIANCE WITH STATE AND FEDERAL REGULATIONS RELATING TO CLEAN AIR AND/OR VENTING OF CFC AND/OR HCFC REFRIGERANTS UNTIL THE EQUIPMENT IS TURNED OVER TO TENANT FOR OPERATION AND MAINTENANCE. THIS RESPONSIBILITY SHALL INCLUDE ALL WORK RELATING TO DISCHARGING ANY AND ALL HVAC REFRIGERANT SYSTEMS OF ANY EXISTING EQUIPMENT REUSED OR REMOVED. 15. G.C. SHALL PROVIDE ALL TEMPORARY SHORING, BRACING & G.C. SHALL PROVIDE ALL TEMPORARY SHORING, BRACING & PINNING OF WALLS REQUIRED TO MAINTAIN INTEGRITY OF WALL CONSTRUCTION DURING DEMOLITION & UNTIL WALL HAS BEEN COMPLETED.
AutoCAD SHX Text
EXISTING CANOPY ABOVE TO REMAIN.
AutoCAD SHX Text
EXISTING CEILING GRID TO REMAIN, REPLACE DAMAGED OR MISSING CEILING TILES. PROTECT FIRE SPRINKLER HEADS DURING CONSTRUCTION. REMOVE EXISTING LIGHTING & RECEPTICALS COMPLETE BACK TO ORIGIN. ALL OTHER CEILING MOUNTED ITEMS (DIFFUSERS, SPEAKERS, ETC.) TO REMAIN. REFER TO ELECTRICAL/MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text
EXPIRES 12/31/20
AutoCAD SHX Text
LIC. # 9222
AutoCAD SHX Text
KRISTEN M. MACK
AutoCAD SHX Text
NOTE: THIS DRAWING SET IS TO BE VIEWED AS A WHOLE. ALL WORK PERTAINING TO A SPECIFIC CONTRACTOR MAY OR MAY NOT BE SHOWN ON SPECIFIC DRAWINGS SECTIONS. IT IS EACH SUBCONTRACTOR'S RESPONSIBILITY TO PREPARE THEIR BID FROM A COMPLETE SET OF CONSTRUTCTION DOCUMENTS.
AutoCAD SHX Text
AIR HANDLERS TO BE REMOVED COMPLETE. ALL UTILITIES TO BE REMOVED BACK TO SOURCE. PATCH AND REPAIR AREA AS REQUIRED. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL USE LANDLORDS ROOFING CONTRACTOR SO WORK WILL NOT VOID WARRANTY.
AutoCAD SHX Text
1
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
EXIST. SPRINKLER SYSTEM TO BE MODIFIED AS REQUIRED TO MEET LOCAL CODES, SEE FIRE PROTECTION NOTES ON CS1. SPRINKLER SYSTEM TO BE SERVICED TO ENSURE PROPER OPERATION. SPRINKLER SYSTEM MODIFICATIONS ARE UNDER SEPARATE PERMIT.
AutoCAD SHX Text
4
AutoCAD SHX Text
EXISTING GUTTER TO REMAIN.
AutoCAD SHX Text
5
AutoCAD SHX Text
EXISTING DOWNSPOUT TO REMAIN.
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
2
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
2
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
03/04/20
AutoCAD SHX Text
TAW
AutoCAD SHX Text
CLARIFICATIONS
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DEMOLITION CEILING PLAN
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NORTH
Page 4: T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO ...summitgc.net/wp-content/uploads/2020/02/Revision-1-Walker-LA-03-04-20.pdf6. all materials indicated are new, unless specifically

12 S

unne

n Dr

ive,

Sui

te 1

00, S

t. Lo

uis,

MO

631

43T:

314

.821

.110

0

AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
ENLARGED TOILET PLAN
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
2
AutoCAD SHX Text
A1
AutoCAD SHX Text
A1
AutoCAD SHX Text
FLOOR PLAN, WALL CONSTRUCTION TYPES,
AutoCAD SHX Text
AND ENLARGED OFFICE, TOILET PLANS
AutoCAD SHX Text
RBM
AutoCAD SHX Text
TAW
AutoCAD SHX Text
TAW
AutoCAD SHX Text
PARTITION WALL: EXISTING 3 5/8" (20 GAUGE) METAL STUDS @ 16" O.C. WITH 5/8" GWB ON BOTH SIDES TO ROOF DECK. SEE DETAIL 9/A4 FOR ADDITIONAL INFORMATION. REFER TO SHEET A3 FOR GONDOLA LOCATION IF REQUIRED. REFER TO SECTION 8/A4 FOR GONDOLA ATTACHMENT. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
PARTITION WALL: NEW 3 5/8" (20 GAUGE) METAL STUDS @ 16" O.C. WITH ONE LAYER OF 5/8" GWB ON ONE SIDE ONLY TO 6" A.F.C. BRACE WALL TO STRUCTURE AS REQUIRED. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
TENANT DEMISING WALL: EXISTING 3 5/8" METAL STUDS @ 16" O.C. ONE LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE TO UNDER SIDE OF ROOF DECK. DESIGNED PER UL U495. ONE HOUR RATING. PATCH AND REPAIR TO LIKE NEW CONDITION. SEE DETAIL 9/A4 FOR ADDITIONAL REQUIREMENTS. REFER TO SHEET A3 FOR GONDOLA LOCATION IF REQUIRED. REFER TO SECTION 8/A4 FOR GONDOLA ATTACHMENT. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
PARTITION WALL: EXISTING 6" (20 GAUGE) METAL STUDS @ 16" O.C. WITH ONE LAYER OF 5/8" WR GWB ON ONE SIDE TO FINISHED CEILING. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
6
AutoCAD SHX Text
4
AutoCAD SHX Text
TENANT DEMISING WALL: EXISTING PEMB WALL WITH EXISTING STUDS AND GWB. PATCH AND REPAIR TO LIKE NEW CONDITIONS. SEE DETAIL 10/A4 FOR ADDITIONAL REQUIREMENTS. REFER TO SHEET A3 FOR GONDOLA LOCATION IF REQUIRED. REFER TO SECTION 8/A4 FOR GONDOLA ATTACHMENT.FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
WALL CONSTRUCTION TYPES
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
PARTITION WALL: NEW 3 5/8" (20 GAUGE) METAL STUDS @ 16" O.C. WITH 5/8" GWB ON ONE SIDE ONLY TO 6" A.F.C. (TO 10'-0" A.F.F. PROVIDE GRILLES FOR VENTILATION AS REQUIRED AT TOP AND BOTTOM @ 16" O.C. - AMERICAN GRILLE AG10 OR EQUAL. BRACE WALL TO STRUCTURE AS REQUIRED. SEE DETAIL 11/A4 FOR ADDITIONAL REQUIREMENTS. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
PARTITION WALL: NEW 3 5/8" (20 GAUGE) METAL STUDS @ 16" O.C. WITH ONE LAYER 5/8" GWB EACH SIDE TO 8'-0" AFF. FINISH PER FINISH SCHEDULE SHEET A4. REFER TO DETAIL 3/A4 FOR ADDITIONAL INFORMATION.
AutoCAD SHX Text
PARTITION WALL: EXISTING 3 5/8" (20 GAUGE) METAL STUDS @ 16" O.C. WITH 5/8" GWB (WR GWB @ PLUMBING FIXTURES) ON EACH SIDE TO 8'-0" A.F.F. BRACE WALL TO STRUCTURE AS REQUIRED. REFER TO DETAIL 12/A4 FOR ADDITIONAL INFORMATION. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
A
AutoCAD SHX Text
A3
AutoCAD SHX Text
1
AutoCAD SHX Text
A1
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
400
AutoCAD SHX Text
2
AutoCAD SHX Text
A1
AutoCAD SHX Text
500
AutoCAD SHX Text
100
AutoCAD SHX Text
300
AutoCAD SHX Text
300
AutoCAD SHX Text
FIRE EXTINGUISHER (SEE NEW WORK NOTE 2 ON SHEET CS1)
AutoCAD SHX Text
EXISTING WOMEN'S TOILET
AutoCAD SHX Text
EXISTING MEN'S TOILET
AutoCAD SHX Text
FIRE EXTINGUISHER (SEE NEW WORK NOTE 2 ON SHEET CS1)
AutoCAD SHX Text
%%USALES
AutoCAD SHX Text
%%UPRE-SALES
AutoCAD SHX Text
200
AutoCAD SHX Text
401
AutoCAD SHX Text
FE
AutoCAD SHX Text
EXISTING STOREFRONT GLAZING SYSTEM (TYP.)
AutoCAD SHX Text
EXISTING SIDEWALK
AutoCAD SHX Text
EXISTING ACCESS RAMP (TYP. OF 2)
AutoCAD SHX Text
F
AutoCAD SHX Text
A3
AutoCAD SHX Text
FE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
ENLARGED EMPLOYEE AREA
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
3
AutoCAD SHX Text
A1
AutoCAD SHX Text
3
AutoCAD SHX Text
A1
AutoCAD SHX Text
4
AutoCAD SHX Text
EMPLOYEE AREA
AutoCAD SHX Text
PRE-WIRED CHECKOUTS
AutoCAD SHX Text
SHOPPING CART BUMPERS, REFER TO F/A4.1
AutoCAD SHX Text
A.9
AutoCAD SHX Text
A
AutoCAD SHX Text
2 DOOR COOLER
AutoCAD SHX Text
5 DOOR FREEZER
AutoCAD SHX Text
5 DOOR FREEZER
AutoCAD SHX Text
24"X96"
AutoCAD SHX Text
24"X96"
AutoCAD SHX Text
UTILITY CABINET
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
LOCKER
AutoCAD SHX Text
A.1
AutoCAD SHX Text
B
AutoCAD SHX Text
COOLER
AutoCAD SHX Text
COOLER
AutoCAD SHX Text
15'-0" x 7'-10"
AutoCAD SHX Text
5
AutoCAD SHX Text
9
AutoCAD SHX Text
D
AutoCAD SHX Text
A3
AutoCAD SHX Text
B
AutoCAD SHX Text
A3
AutoCAD SHX Text
C
AutoCAD SHX Text
A3
AutoCAD SHX Text
E
AutoCAD SHX Text
A3
AutoCAD SHX Text
EXISTING SIDEWALK AND SITE CONDITIONS NOT A PART OF PROJECT SCOPE. LANDLORD PROPERTY.
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
LOCKER
AutoCAD SHX Text
UTILITY CABINET
AutoCAD SHX Text
EXISTING BLACK FILM ON INTERIOR OF GLAZING TO REMAIN.
AutoCAD SHX Text
NEW ALUMINUM STOREFRONT SYSTEM REFER TO "NEW WORK NOTES" #20 ON SHEET CS1
AutoCAD SHX Text
NOTE: SEE 'GENERAL SITE ACCESSIBILITY NOTES', SHEET CS1, FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX Text
NOTE: VERIFY LOCATION OF CHECKOUTS, REACH-IN F/C & WALK-IN F/C WITH FIXTURE PLAN. IF THERE IS ANY CONFLICTS WITH LOCATIONS OF CHECKOUTS, CONTACT CONSTRUCTION PROJECT MANAGER FOR DIRECTION.
AutoCAD SHX Text
NOTE: CONTRACTOR SHALL VERIFY WITH DOLLAR TREE CONSTRUCTION PROJECT MANAGER ANY PROPOSED CUSTOM INTERIOR WINDOW GRAPHICS/FILM PRIOR TO BUILDING INFILL WALL AT STOREFRONT.
AutoCAD SHX Text
F R P (FIBERGLASS REINFORCED PANEL) TO 4'-0" A.F.F. ON SALES FLOOR (ON AREAS NOT COVERED BY GONDOLA UNITS, TYP.) SHALL BE ALMOND COLOR WITH "J" CHANNEL TRIM CAP AND "H" CHANNEL PANEL CONNECTORS.
AutoCAD SHX Text
NOTE: ALL ADA COMPLIANCE AND SITE PLANNING ISSUES OUTSIDE THE DOLLAR TREE LEASED PREMISES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER, THEIR CONSULTANTS, PROPERTY MANAGERS, AND/OR ASSIGNED REPRESENTATIVES.
AutoCAD SHX Text
NEW CARPET TILE W/ TRANSITION STRIP. SEE NEW WORK NOTE #17 ON SHEET CS1.
AutoCAD SHX Text
SAFE (TENANT SUPPLIED) BOLT TO FLOOR
AutoCAD SHX Text
POWER POLE FOR CHECKOUT REGISTER WIRING (SUPPLIED BY TENANT) (TYP. OF 4)
AutoCAD SHX Text
EXISTING H.M. EXTERIOR DOOR & FRAME. G.C. TO VERIFY FIN. FLOOR AND EXTERIOR GRADE, NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS OR IF FIN. FLOOR IS MORE THAN 1/2" ABOVE GRADE
AutoCAD SHX Text
AREA OF ELECTRICAL PANELS - SEE ELECTRICAL DWGS.
AutoCAD SHX Text
EMS PANEL
AutoCAD SHX Text
TELEPHONE BOARD
AutoCAD SHX Text
EXISTING BOLLARDS (TYP. OF 5)
AutoCAD SHX Text
EXISTING CONDENSING UNITS (TYP. OF 2)
AutoCAD SHX Text
EXTERIOR NOT PART OF DESIGN SCOPE. LANDLORD RESPONSIBILITY.
AutoCAD SHX Text
ALARM SYSTEM. REFER TO DETAIL B/A4.1
AutoCAD SHX Text
project
AutoCAD SHX Text
drawing
AutoCAD SHX Text
project
AutoCAD SHX Text
date
AutoCAD SHX Text
designed
AutoCAD SHX Text
drawn
AutoCAD SHX Text
checked
AutoCAD SHX Text
mark
AutoCAD SHX Text
revisions
AutoCAD SHX Text
date
AutoCAD SHX Text
by
AutoCAD SHX Text
description
AutoCAD SHX Text
PHONE: 314-821-1100
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
28050 WALKER ROAD SOUTH, WALKER, LA 70785
AutoCAD SHX Text
520574
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
PROFESSIONAL OF RECORD
AutoCAD SHX Text
CASCO DIVERSIFIED CORPORATION ARCHITECTURAL FIRM LICENSE #AE0220 EXPIRES 6/30/20
AutoCAD SHX Text
EXPIRES 12/31/20
AutoCAD SHX Text
LIC. # 9222
AutoCAD SHX Text
KRISTEN M. MACK
AutoCAD SHX Text
FREEZER/COOLER VENDOR TO INSTALL WALK-IN COOLER UNIT PER MANUFACTURER'S SPECIFICATIONS.
AutoCAD SHX Text
FREEZER/COOLER VENDOR TO INSTALL WALK-IN FREEZER UNITS PER MANUFACTURER'S SPECIFICATIONS.
AutoCAD SHX Text
5 1/2" X 1 1/2" (18 GA) STEEL ANGLE - SEE DETAIL K/A4.1.
AutoCAD SHX Text
FIRE EXTINGUISHER (SEE NEW WORK NOTE 2 ON SHEET CS1)
AutoCAD SHX Text
FE
AutoCAD SHX Text
FE
AutoCAD SHX Text
FREEZER/COOLER VENDOR TO INSTALL REACH-IN COOLER UNIT PER MANUFACTURER'S SPECIFICATIONS.
AutoCAD SHX Text
5 1/2" X 1 1/2" (18 GA) STEEL ANGLE - SEE DETAIL K/A4.1.
AutoCAD SHX Text
FREEZER/COOLER VENDOR TO INSTALL REACH-IN FREEZER UNIT PER MANUFACTURER'S SPECIFICATIONS.
AutoCAD SHX Text
9
AutoCAD SHX Text
9
AutoCAD SHX Text
8
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
EXISTING ALUM./GLASS DOORS, REMOVE EGRESS HARDWARE COMPLETE AND LOCK IN CLOSED POSITION. COVER HOLES AS REQUIRED.
AutoCAD SHX Text
EXISTING SANITARY CLEAN OUT (TYP.)
AutoCAD SHX Text
7
AutoCAD SHX Text
1
AutoCAD SHX Text
A4
AutoCAD SHX Text
7
AutoCAD SHX Text
9
AutoCAD SHX Text
A4
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
3
AutoCAD SHX Text
E
AutoCAD SHX Text
A4.2
AutoCAD SHX Text
3
AutoCAD SHX Text
8
AutoCAD SHX Text
8
AutoCAD SHX Text
EXISTING ACCESS RAMP (TYP.)
AutoCAD SHX Text
1.2
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
EXISTING H.M. EXTERIOR DOOR & FRAME. G.C. TO VERIFY FIN. FLOOR AND EXTERIOR GRADE, NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS OR IF FIN. FLOOR IS MORE THAN 1/2" ABOVE GRADE
AutoCAD SHX Text
10
AutoCAD SHX Text
A4
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
FE
AutoCAD SHX Text
4
AutoCAD SHX Text
A4
AutoCAD SHX Text
3
AutoCAD SHX Text
A4
AutoCAD SHX Text
6
AutoCAD SHX Text
A4
AutoCAD SHX Text
100
AutoCAD SHX Text
3
AutoCAD SHX Text
A4
AutoCAD SHX Text
7
AutoCAD SHX Text
A4
AutoCAD SHX Text
11
AutoCAD SHX Text
A4
AutoCAD SHX Text
A2
AutoCAD SHX Text
C
AutoCAD SHX Text
A2
AutoCAD SHX Text
E
AutoCAD SHX Text
A2
AutoCAD SHX Text
D
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
SHELVING ABOVE
AutoCAD SHX Text
2 1/2" DIA GROMMETED HOLE AT COUNTER AND 15" SHELF ABOVE (TYP OF 2)
AutoCAD SHX Text
CLIPBOARD RACK - SEE DETAIL D/A4.1.
AutoCAD SHX Text
SIM
AutoCAD SHX Text
BULLETIN BOARD (TENANT SUPPLIED) - MOUNT ABOVE CLIPBOARD RACK.
AutoCAD SHX Text
SAFE (TENANT SUPPLIED) BOLT TO FLOOR
AutoCAD SHX Text
PROVIDE PREFORMED COUNTER AND BACKSPLASH W/ HIGH PRESSURE WHITE LAMINATE FINISH. MOUNT TO WALL. SEE OFFICE ELEVATION E/A2 & DETAILS F/A2 & G/A2.
AutoCAD SHX Text
EXISTING STOREFRONT GLAZING. PROVIDE OPAQUE WINDOW FILM ON INTERIOR FACE OF GLASS PRIOR TO INSTALLING INFILL WALL. PROVIDE GRILLES FOR VENTILATION AS REQUIRED - AMERICAN GRILLE AG10 OR EQUAL.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
ENLARGED OFFICE PLAN
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
1
AutoCAD SHX Text
A1
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CLEAR
AutoCAD SHX Text
CLEAR
AutoCAD SHX Text
PAINT OSHA YELLOW
AutoCAD SHX Text
12
AutoCAD SHX Text
A4
AutoCAD SHX Text
HANDICAPPED ACCESSIBLE HI/LO DRINKING FOUNTAIN REFER TO A/A4.1 FRP ON WALLS ADJACENT TO DF FROM 4" TO 4'-0" AFF
AutoCAD SHX Text
12
AutoCAD SHX Text
A4
AutoCAD SHX Text
HAND DRYER, TENANT SUPPLIED (TYP.)
AutoCAD SHX Text
9
AutoCAD SHX Text
A4
AutoCAD SHX Text
A2
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
OPP. HD.
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
H
AutoCAD SHX Text
E
AutoCAD SHX Text
WOMEN'S TOILET
AutoCAD SHX Text
MEN'S TOILET
AutoCAD SHX Text
10
AutoCAD SHX Text
A4
AutoCAD SHX Text
AutoCAD SHX Text
WATER HEATER MTD ABOVE MOP SINK ON STEEL FRAME. REFER TO DETAIL E/A4.1.
AutoCAD SHX Text
MOP SINK - PROVIDE FRP TO 8'-0" AFF ON ALL ADJACENT WALLS REFER TO H/A4.1
AutoCAD SHX Text
AutoCAD SHX Text
DECK HEIGHT: 14'-4"
AutoCAD SHX Text
%%USQUARE FOOTAGES
AutoCAD SHX Text
TOTAL SPACE LEASED:
AutoCAD SHX Text
NON-SALES AREA:
AutoCAD SHX Text
USABLE STOCKROOM:
AutoCAD SHX Text
SF
AutoCAD SHX Text
SF
AutoCAD SHX Text
SF
AutoCAD SHX Text
CEILING HEIGHT
AutoCAD SHX Text
CITY:
AutoCAD SHX Text
SHOPPING CENTER:
AutoCAD SHX Text
%%UGENERAL INFORMATION:
AutoCAD SHX Text
STATE:
AutoCAD SHX Text
(SALES AREA):
AutoCAD SHX Text
SALES FLOOR AREA:
AutoCAD SHX Text
SF
AutoCAD SHX Text
USABLE SALES FLOOR
AutoCAD SHX Text
SPRINKLERED:
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
YES
AutoCAD SHX Text
10,000
AutoCAD SHX Text
1,630
AutoCAD SHX Text
16.3%
AutoCAD SHX Text
1,056
AutoCAD SHX Text
10.6%
AutoCAD SHX Text
11'-0" AFF
AutoCAD SHX Text
WALKER
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
SHOPPING CENTER
AutoCAD SHX Text
LOUISIANA
AutoCAD SHX Text
8,370
AutoCAD SHX Text
7,852
AutoCAD SHX Text
EXISTING FLOOR DRAIN (TYP. OF 2)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
A4.1
AutoCAD SHX Text
L
AutoCAD SHX Text
EXISTING SANITARY CLEAN OUT
AutoCAD SHX Text
A4.2
AutoCAD SHX Text
D
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A4.2
AutoCAD SHX Text
CLEAR
AutoCAD SHX Text
PREFORMED COUNTER - REFER TO ELEVATION D/A4.2 & DETAILS B/A4.2 & C/A4.2
AutoCAD SHX Text
COAT RACK REFER TO A/A4.2
AutoCAD SHX Text
LOCKERS REFER TO D/A4.2
AutoCAD SHX Text
BULLETIN BOARD (TENANT SUPPLIED) - MOUNT AT 4'-0" AFF.
AutoCAD SHX Text
1
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
6
AutoCAD SHX Text
6
AutoCAD SHX Text
11
AutoCAD SHX Text
A4
AutoCAD SHX Text
%%UEXISTING
AutoCAD SHX Text
9
AutoCAD SHX Text
9
AutoCAD SHX Text
A2
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
TENANT DEMISING WALL: NEW 6" METAL STUDS @ 16" O.C. ONE LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE TO UNDER SIDE OF ROOF DECK. DESIGNED PER UL U495. ONE HOUR RATING. SEE DETAIL E/A4.2 FOR ADDITIONAL REQUIREMENTS. REFER TO SHEET A3 FOR GONDOLA LOCATION IF REQUIRED. REFER TO SECTION 8/A4 FOR GONDOLA ATTACHMENT. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
3
AutoCAD SHX Text
PARTITION WALL: NEW 3 5/8" (20 GAUGE) METAL STUDS @ 16" O.C. WITH 5/8" GWB ON BOTH SIDES TO ROOF DECK. SEE DETAIL 9/A4 FOR ADDITIONAL INFORMATION. REFER TO SHEET A3 FOR GONDOLA LOCATION IF REQUIRED. REFER TO SECTION 8/A4 FOR GONDOLA ATTACHMENT. FINISH PER FINISH SCHEDULE, SHEET A4.
AutoCAD SHX Text
10
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
03/04/20
AutoCAD SHX Text
TAW
AutoCAD SHX Text
CLARIFICATIONS
AutoCAD SHX Text
EXISTING SIDEWALK
AutoCAD SHX Text
NEW CONDENSING UNITS (TYP. OF 4)
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
EXISTING ASPHALT AND CONCRETE
AutoCAD SHX Text
6" DIA STEEL PIPE BOLLARD CONCRETE FILLED
AutoCAD SHX Text
PAINT 'OSHA YELLOW'
AutoCAD SHX Text
SMOOTH CONCRETE DOMED FINISH TO BE PAINTED "OSHA YELLOW"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NEW BOLLARD DETAIL
AutoCAD SHX Text
1 1/2" = 1'-0"
AutoCAD SHX Text
4
AutoCAD SHX Text
A1
AutoCAD SHX Text
PROVIDE 6" STEEL PIPE BOLLARDFILLED WITH CONC EMBEDDED INTO CONC BASE 12" X 12" PIER, 24" MIN IN GROUND AND 42" EXPOSED ABOVE GROUND (TYP OF 8) - PAINT YELLOW. SEE DETAIL 4/A1 FOR MORE INFORMATION.
AutoCAD SHX Text
LINE OF CANOPY ABOVE REFER TO SHEET A3 FOR ADDITIONAL INFORMATION
AutoCAD SHX Text
EXISTING ALUM./GLASS DOORS, REMOVE EGRESS HARDWARE COMPLETE AND LOCK IN CLOSED POSITION. COVER HOLES AS REQUIRED.
AutoCAD SHX Text
EXISTING STOREFRONT GLAZING, APPLY OPAQUE FILM ON INTERIOR FACE OF GLASS PRIOR TO INSTALLING INFILL WALL.
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
Page 5: T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO ...summitgc.net/wp-content/uploads/2020/02/Revision-1-Walker-LA-03-04-20.pdf6. all materials indicated are new, unless specifically

12 S

unne

n Dr

ive,

Sui

te 1

00, S

t. Lo

uis,

MO

631

43T:

314

.821

.110

0

METAL FILE

CABINET

METAL FILE

CABINET

SS

AutoCAD SHX Text
project
AutoCAD SHX Text
drawing
AutoCAD SHX Text
project
AutoCAD SHX Text
date
AutoCAD SHX Text
designed
AutoCAD SHX Text
drawn
AutoCAD SHX Text
checked
AutoCAD SHX Text
mark
AutoCAD SHX Text
revisions
AutoCAD SHX Text
date
AutoCAD SHX Text
by
AutoCAD SHX Text
description
AutoCAD SHX Text
PHONE: 314-821-1100
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
28050 WALKER ROAD SOUTH, WALKER, LA 70785
AutoCAD SHX Text
520574
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
PROFESSIONAL OF RECORD
AutoCAD SHX Text
CASCO DIVERSIFIED CORPORATION ARCHITECTURAL FIRM LICENSE #AE0220 EXPIRES 6/30/20
AutoCAD SHX Text
A2
AutoCAD SHX Text
REFLECTED CEILING PLAN, LEGEND & NOTES
AutoCAD SHX Text
OFFICE ELEVATIONS & TOILET ELEVATIONS
AutoCAD SHX Text
RBM
AutoCAD SHX Text
TAW
AutoCAD SHX Text
TAW
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
REFLECTED CEILING PLAN
AutoCAD SHX Text
1/8"=1'-0"
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NEW 11'-0"%%P
AutoCAD SHX Text
OFFICE WALLS BELOW
AutoCAD SHX Text
NO FINISHED CEILING EXPOSED TO ROOF STRUCTURE ABOVE.
AutoCAD SHX Text
BOTTOM OF ROOF DECK HEIGHT @ 14'-4"± A.F.F.
AutoCAD SHX Text
BOTTOM OF ROOF DECK HEIGHT @ 14'-4"± A.F.F.
AutoCAD SHX Text
EXISTING GUTTER
AutoCAD SHX Text
EXISTING DOWNSPOUT (TYP.)
AutoCAD SHX Text
11'-0"%%P
AutoCAD SHX Text
LINE OF CANOPY. REFER TO SHEET A3 FOR ADDITIONAL INFORMATION
AutoCAD SHX Text
1.2
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
A.9
AutoCAD SHX Text
A
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
NL
AutoCAD SHX Text
NL
AutoCAD SHX Text
NL
AutoCAD SHX Text
NL
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
NL
AutoCAD SHX Text
EM
AutoCAD SHX Text
NL
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
A.1
AutoCAD SHX Text
B
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
OFFICE SECTION
AutoCAD SHX Text
1"=1'-0"
AutoCAD SHX Text
G
AutoCAD SHX Text
A2
AutoCAD SHX Text
LINE OF ADJACENT WALL (TYP)
AutoCAD SHX Text
NOTE::
AutoCAD SHX Text
SHELF FRAMING ABOVE SHALL BE SIMILAR - SEE ELEVATION.
AutoCAD SHX Text
F
AutoCAD SHX Text
A2
AutoCAD SHX Text
PROVIDE CONT. FIRE RETARDANT 2X4 WD LEDGER - ATTACH TO ADJACENT WALL @ 8" OC MAX.
AutoCAD SHX Text
PROVIDE FIRE RETARDANT 2X4 WD CENTER SUPPORT
AutoCAD SHX Text
PROVIDE FIRE RETARDANT 2X4 ENDCAP SUPPORT (EA SIDE TYP) - ATTACH @ 8" OC MAX.
AutoCAD SHX Text
LINE OF COUNTER ABOVE - HOLD BACK 2X4 FRAMING AS REQ'D FOR INSTALLATION OF COUNTER
AutoCAD SHX Text
FIRE RETARDANT 2X4 WD. SUPPORT
AutoCAD SHX Text
EQ
AutoCAD SHX Text
EQ
AutoCAD SHX Text
10'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
OFFICE SECTION
AutoCAD SHX Text
1"=1'-0"
AutoCAD SHX Text
F
AutoCAD SHX Text
A2
AutoCAD SHX Text
G
AutoCAD SHX Text
A2
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
FIRE RETARDANT 2X4 WD SUPPORT FRAME
AutoCAD SHX Text
CONT. FIRE RETARDANT 2X4 WD FRAME ATTACHED TO WALL PAINT FRAMING WHITE
AutoCAD SHX Text
PROVIDE 3/4" X 15" WHITE MELAMINE SHELF
AutoCAD SHX Text
2 1/2" HOLE WITH GROMMENT. SEE ELEVATION FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX Text
PROVIDE PREFORMED WHITE LAMINATE COUNTER TOP WITH BACKSPLASH.
AutoCAD SHX Text
PAINT ALL FRAMING WHITE.
AutoCAD SHX Text
ATTACH FRAME TO ADJACENT WALL
AutoCAD SHX Text
PROVIDE VERT. FIRE RETARDANT 2X4 WD FRAME SUPPORT AT CENTER OF COUNTER.
AutoCAD SHX Text
ATTACH FRAME TO SLAB
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
OFFICE ELEVATION
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
E
AutoCAD SHX Text
A2
AutoCAD SHX Text
4" VINYL COVE BASE
AutoCAD SHX Text
CLEAR
AutoCAD SHX Text
FIRE RETARDANT 2X4 WD SILL SHOT TO FLOOR.
AutoCAD SHX Text
(3) FIRE RETARDANT 2X4 WD SUPPORT LEGS AT FRONT, CENTER AND WALL. REFER TO SECTION.
AutoCAD SHX Text
3'-6"(H) x 2'-6"(W) 3/4" PLYWOOD BACKBOARD INSTALLED BY CONTRACTOR. TOP OF BOARD AT 8'-0" AFF. PAINT WHITE
AutoCAD SHX Text
F
AutoCAD SHX Text
A2
AutoCAD SHX Text
PROVIDE (1) 15" DEEP 3/4" WHITE MELAMINE SHELF SUPPORT WITH 2X4 WOOD CONSTRUCTION. PROVIDE (2) 2 1/2" DIA. HOLES W/ GROMMETS FOR PRINTER AND CCTV. (1) AT EACH END DIRECTLY ABOVE HOLES IN COUNTER. SEE ENLARGED OFFICE PLAN.
AutoCAD SHX Text
PROVIDE 10" WIDE 3/4" WHITE MELAMINE SHELF. SUPPORT W/ SHELF BRACKETS. (CUT 30" OFF TOTAL & OFFSET SHELF TO RIGHT).
AutoCAD SHX Text
PROVIDE 10" WIDE 3/4" WHITE MELAMINE SHELF. SUPPORT W/ TENANT SUPPLIED SHELF BRACKETS.
AutoCAD SHX Text
FILE CABINETS (SUPPLIED BY TENANT)
AutoCAD SHX Text
TOP OF SLATWALL
AutoCAD SHX Text
FIRE RETARDANT 2X4 SUPPORT FRAMING ATTACHED TO WALL.
AutoCAD SHX Text
2-1/2" DIA HOLE W/ GROMMET (TYP OF 2)
AutoCAD SHX Text
PRE-FORMED WHITE LAMINATE COUNTER - SUPPORT WITH FIRE RETARDANT 2X4 WOOD CONSTRUCTION.
AutoCAD SHX Text
NOTE: 1. THE ELECTRICIAN SHALL INSTALL ADDITIONAL WIRE TIE SUPPORTS FROM THE CEILING GRID THE ELECTRICIAN SHALL INSTALL ADDITIONAL WIRE TIE SUPPORTS FROM THE CEILING GRID TO THE STRUCTURE ABOVE FOR SUPPORT OF THE LIGHT FIXTURES CLIPPED ON THE GRID. 2. LIGHT FIXTURES ARE SUPPLIED BY TENANT FOR CONTRACTOR'S INSTALLATION. LIGHT FIXTURES ARE SUPPLIED BY TENANT FOR CONTRACTOR'S INSTALLATION. 3. MOUNT LIGHTS AT 10'-0" A.F.F. IN STOCKROOM. MOUNT LIGHTS AT 10'-0" A.F.F. IN STOCKROOM. 4. SPRINKLER HEADS ARE SHOWN GRAPHICALLY. CONTRACTOR SHALL PREPARE DRAWINGS AS SPRINKLER HEADS ARE SHOWN GRAPHICALLY. CONTRACTOR SHALL PREPARE DRAWINGS AS REQUIRED BY CODE. REFER TO DEFERRED SUBMITTAL ON SHEET CS1. 5. NEW CEILING GRID, SPACING AND HEIGHT SHALL MATCH EXISTING MAIN CEILING HEIGHT OF NEW CEILING GRID, SPACING AND HEIGHT SHALL MATCH EXISTING MAIN CEILING HEIGHT OF 11'-0" A.F.F.
AutoCAD SHX Text
TWO ROLL TOILET PAPER DISPENSER (TYP OF 2 PER WATER CLOSET). PROVIDE BLOCKING IN WALL AS REQ'D.
AutoCAD SHX Text
A
AutoCAD SHX Text
A2
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
TOILET ELEVATION
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
WRAP PIPES AS REQUIRED BY ADA.
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
18" VERTICAL MOUNTED GRAB BAR (PROVIDE BLOCKING IN WALL AS REQ'D)
AutoCAD SHX Text
TO REFLECTIVE SURFACE
AutoCAD SHX Text
B
AutoCAD SHX Text
A2
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
TOILET ELEVATION
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
18"
AutoCAD SHX Text
18"
AutoCAD SHX Text
18"
AutoCAD SHX Text
L
AutoCAD SHX Text
C
AutoCAD SHX Text
36" GRAB BAR (PROVIDE BLOCKING IN WALL AS REQ'D)
AutoCAD SHX Text
FRP - SEE FINISH NOTES SHEET A4
AutoCAD SHX Text
FRP - SEE FINISH NOTES SHEET A4
AutoCAD SHX Text
18" VERTICAL MOUNTED GRAB BAR (PROVIDE BLOCKING IN WALL AS REQ'D)
AutoCAD SHX Text
42" GRAB BAR (PROVIDE BLOCKING IN WALL AS REQ'D)
AutoCAD SHX Text
TWO ROLL TOILET PAPER DISPENSER (TYP OF 2 PER WATER CLOSET). PROVIDE BLOCKING IN WALL AS REQ'D.
AutoCAD SHX Text
VINYL BASE
AutoCAD SHX Text
NOTE: TOILET ACCESSORIES ARE TENANT SUPPLIED - INCLUDING GRAB BARS, TOILET PAPER DISPENSER, MIRROR AND HAND DRYER. THE ELECTRIC HAND DRYER WILL NOT EXTEND MORE THAN 4" FROM THE WALL ON WHICH IT IS MOUNTED UNLESS IT HAS A LEADING EDGE AT OR BELOW 27" ABOVE FINISHED FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET.
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
CHECKOUTS BELOW (TYP.)
AutoCAD SHX Text
REFLECTED CEILING LEGEND
AutoCAD SHX Text
SCD
AutoCAD SHX Text
NL
AutoCAD SHX Text
EM
AutoCAD SHX Text
EXTERIOR EMERGENCY LIGHT AND BATTERY BACKUP.
AutoCAD SHX Text
CONCENTRIC DIFFUSER/RETURN
AutoCAD SHX Text
NL
AutoCAD SHX Text
NEW 2'-0"X4'-0" ACOUSTICAL CEILING TILE AND GRID- SEE FINISH NOTE 4.
AutoCAD SHX Text
NEW GWB - PAINT WHITE UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
EXIT LIGHT
AutoCAD SHX Text
VENTILATION FAN
AutoCAD SHX Text
CEILING HEIGHT ABOVE FINISH FLOOR
AutoCAD SHX Text
POWER POLE
AutoCAD SHX Text
RETURN AIR GRILLE
AutoCAD SHX Text
DIFFUSER
AutoCAD SHX Text
SECURITY CAMERA DOME
AutoCAD SHX Text
SECURITY CAMERA DOME MTD ON WALL @ 10'-0" AFF.
AutoCAD SHX Text
CEILING OCCUPANCY SENSOR MODEL CMR-PDT-2P
AutoCAD SHX Text
EM
AutoCAD SHX Text
NEW 8'-0" STRIP LED LIGHT FIXTURE WITH LAMPS ON NIGHT LIGHT CIRCUIT. SURFACE MOUNT TO GWB, ACT CEILING OR PER DETAIL NOTED.
AutoCAD SHX Text
NEW 4'-0" STRIP LED LIGHT FIXTURE WITH LAMPS ON NIGHT LIGHT CIRCUIT. SURFACE MOUNT TO TO GWB, ACT CEILING OR PER DETAIL NOTED.
AutoCAD SHX Text
NEW 4'-0" STRIP LED LIGHT FIXTURE. SURFACE MOUNT TO ACT, GWB CEILING OR PER DETAIL NOTED.
AutoCAD SHX Text
NEW 4'-0" STRIP LED LIGHT FIXTURE WITH LAMPS ON EMERGENCY LIGHT CIRCUIT WITH BATTERY PACK. SURFACE MOUNT TO TO GWB, ACT CEILING OR PER DETAIL NOTED.
AutoCAD SHX Text
NEW 8'-0" STRIP LED LIGHT FIXTURE WITH LAMPS ON EMERGENCY LIGHT CIRCUIT WITH BATTERY PACK. SURFACE MOUNT TO GWB, ACT CEILING OR PER DETAIL NOTED. FOR FIXTURES WITH 2 LAMPS, THE EMERGENCY BATTERY PACK WILL ONLY OPERATE 1 OF THE LAMPS.
AutoCAD SHX Text
INTERIOR EMERGENCY LIGHT AND BATTERY BACKUP.
AutoCAD SHX Text
*
AutoCAD SHX Text
SPRINKLER HEAD (SHOWN FOR INFORMATIONAL PURPOSES ONLY. SPRINKLER CONTRACTOR SHALL PREPARE DRAWINGS AS REQUIRED BY CODE FOR RELOCATION OR ADDITION OF HEADS.)
AutoCAD SHX Text
EM
AutoCAD SHX Text
EM
AutoCAD SHX Text
NEW 8'-0'' LED STRIP LIGHT WITH INTEGRAL BATTERY UNIT. SURFACE MOUNT TO GWB, ACT CEILING OR PER DETAIL NOTED. EMERGENCY LIGHT - WIRE BATTERY INVERTER TO HOT WIRE. FOR FIXTURES WITH 2 LAMPS, THE INTEGRAL BATTERY WILL ONLY OPERATE 1 OF THE LAMPS.
AutoCAD SHX Text
NEW 4'-0" STRIP LED LIGHT WITH INTEGRAL BATTERY UNIT. SURFACE MOUNT TO TO GWB, ACT CEILING OR PER DETAIL NOTED. EMERGENCY LIGHT - WIRE BATTERY INVERTER TO HOT WIRE.
AutoCAD SHX Text
EXIST 8'-0" STRIP LIGHT FIXTURE. SURFACE MOUNT TO GWB, ACT CEILING OR PER DETAIL NOTED.
AutoCAD SHX Text
NEW 8'-0" STRIP LED LIGHT FIXTURE. SURFACE MOUNT TO GWB, ACT CEILING OR PER DETAIL NOTED.
AutoCAD SHX Text
EXIST 4'-0" STRIP LIGHT FIXTURE. SURFACE MOUNT TO GWB, ACT CEILING OR PER DETAIL NOTED.
AutoCAD SHX Text
MIRROR PANEL
AutoCAD SHX Text
SECURITY MONITOR
AutoCAD SHX Text
ELECTRIC HAND DRYER
AutoCAD SHX Text
SOAP DISPENSER
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
EXPIRES 12/31/20
AutoCAD SHX Text
LIC. # 9222
AutoCAD SHX Text
KRISTEN M. MACK
AutoCAD SHX Text
8'-0"%%p
AutoCAD SHX Text
8'-0"%%p
AutoCAD SHX Text
8'-0"%%p
AutoCAD SHX Text
NEW 11'-0"%%P
AutoCAD SHX Text
NOTE: "THE EXISTING FIRE SPRINKLER RISER SERVING THE DOLLAR TREE SPACE IS CURRENTLY BEING ELECTRONICALLY MONITORED BY A FIRE ALARM CONTROL PANEL LOCATED OUTSIDE OG THE PROPOSED DOLLAR TREE SPACE. THE PROPOSED DOLLAR TREE SPACE HAS AN OCCUPANT LOAD OF LESS THAN 500 AND THEREFORE DOES NOT REQUIRE OCCUPANT NOTIFICATION. DOES NOT REQUIRE OCCUPANT NOTIFICATION. REQUIRE OCCUPANT NOTIFICATION. THEREFORE, THE EXISTING FIRE ALARM SYSTEM SHALL CONTINUE TO MONITOR THE FIRE SPRINKLER SYSTEM AS CURRENTLY CONFIGURED."
AutoCAD SHX Text
BOTTOM OF ROOF DECK HEIGHT @ 14'-4"± A.F.F.
AutoCAD SHX Text
BOTTOM OF ROOF DECK HEIGHT @ 14'-4"± A.F.F.
AutoCAD SHX Text
11'-0"%%P
AutoCAD SHX Text
EXISTING 2'-0"X4'-0" ACOUSTICAL CEILING TILE AND GRID- SEE FINISH NOTE 4.
AutoCAD SHX Text
1 X 4 POPLAR WOOD TRIM- PAINT WHITE
AutoCAD SHX Text
ONE WAY VISION MIRROR GLASS (TEMPERED)
AutoCAD SHX Text
VINYL BASE
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
SLATWALL FINISH
AutoCAD SHX Text
VINYL BASE
AutoCAD SHX Text
ALMOND FRP TO 4'-0" A.F.F.
AutoCAD SHX Text
WHITE FRP - OUTSIDE CORNER
AutoCAD SHX Text
1 X 4 POPLAR WOOD TRIM- PAINT WHITE. NOTCH TRIM AS REQ'D FOR GONDOLA
AutoCAD SHX Text
ONE WAY VISION MIRROR GLASS (TEMPERED)
AutoCAD SHX Text
SIM
AutoCAD SHX Text
3
AutoCAD SHX Text
A4
AutoCAD SHX Text
4
AutoCAD SHX Text
A4
AutoCAD SHX Text
3
AutoCAD SHX Text
A4
AutoCAD SHX Text
4
AutoCAD SHX Text
A4
AutoCAD SHX Text
6
AutoCAD SHX Text
A4
AutoCAD SHX Text
C
AutoCAD SHX Text
A2
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
OFFICE ELEVATION
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
D
AutoCAD SHX Text
A2
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
OFFICE ELEVATION
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
NEW AIR HANDLING UNITS MOUNTED BELOW DECK. (TYP. OF 6) REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR MORE INFORMATION.
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
03/04/20
AutoCAD SHX Text
TAW
AutoCAD SHX Text
CLARIFICATIONS
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
Page 6: T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO ...summitgc.net/wp-content/uploads/2020/02/Revision-1-Walker-LA-03-04-20.pdf6. all materials indicated are new, unless specifically

12 S

unne

n Dr

ive,

Sui

te 1

00, S

t. Lo

uis,

MO

631

43T:

314

.821

.110

0

ONLY

EMPLOYEES

ONLY

EMPLOYEES

AutoCAD SHX Text
A3
AutoCAD SHX Text
EXTERIOR ELEVATION &
AutoCAD SHX Text
INTERIOR ELEVATIONS
AutoCAD SHX Text
RBM
AutoCAD SHX Text
TAW
AutoCAD SHX Text
TAW
AutoCAD SHX Text
project
AutoCAD SHX Text
drawing
AutoCAD SHX Text
project
AutoCAD SHX Text
date
AutoCAD SHX Text
designed
AutoCAD SHX Text
drawn
AutoCAD SHX Text
checked
AutoCAD SHX Text
mark
AutoCAD SHX Text
revisions
AutoCAD SHX Text
date
AutoCAD SHX Text
by
AutoCAD SHX Text
description
AutoCAD SHX Text
PHONE: 314-821-1100
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
28050 WALKER ROAD SOUTH, WALKER, LA 70785
AutoCAD SHX Text
520574
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
PROFESSIONAL OF RECORD
AutoCAD SHX Text
CASCO DIVERSIFIED CORPORATION ARCHITECTURAL FIRM LICENSE #AE0220 EXPIRES 6/30/20
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
EXTERIOR ELEVATION
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
A
AutoCAD SHX Text
A3
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
INTERIOR ELEVATION
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
B
AutoCAD SHX Text
A3
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
INTERIOR ELEVATION
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
C
AutoCAD SHX Text
A3
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
INTERIOR ELEVATION
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
E
AutoCAD SHX Text
A3
AutoCAD SHX Text
CONTRACTOR SHALL INSTALL TENANT SUPPLIED 5"x 5" ENTRANCE ACCESSIBILITY DECAL ON STOREFRONT GLAZING. DECAL SHALL BE MOUNTED TO THE RIGHT OF THE MAIN ENTRANCE STOREFRONT DOOR (DO NOT MOUNT NEXT TO EXIT DOORS).
AutoCAD SHX Text
NOTE: IF HARD SURFACE EXIST NEXT TO STOREFRONT ENTRANCE DOOR, CONTRACTOR SHALL SUPPLY AND INSTALL BACKER FOR DECAL TO ADHERE TO AND ATTACH TO HARD SURFACE AS REQUIRED.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
STOREFRONT ENTRANCE
AutoCAD SHX Text
ACCESSIBILITY DECAL AT
AutoCAD SHX Text
3/8"=1'-0"
AutoCAD SHX Text
F
AutoCAD SHX Text
A3
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
INTERIOR ELEVATION
AutoCAD SHX Text
3/16"=1'-0"
AutoCAD SHX Text
D
AutoCAD SHX Text
A3
AutoCAD SHX Text
NOTE: : SIGNS, LOCATION, NUMBER AND SIZE ARE NOT APPROVED UNDER THIS BUILDING PERMIT. A SEPARATE SIGN LOCATION PERMIT IS REQUIRED FOR EACH SIGN.
AutoCAD SHX Text
NOTES: CONTRACTOR SHALL REMOVE AND DISPOSE OF ANY AND ALL PREVIOUS TENANT'S EXTERIOR SIGNAGE LEFT BEHIND. ALL EXISTING MATERIALS TO REMAIN WHICH ARE DAMAGED OR OTHERWISE DISTURBED BY REMOVAL OF PREVIOUS TENANT SIGNAGE SHALL BE PATCHED OR REPAIRED AND PAINTED TO MATCH EXISTING ADJACENT MATERIALS SO THAT THE REPAIR IS IMPERCEPTIBLE. CONTRACTORS SHALL NOT INCLUDE THIS SCOPE OF WORK IN THEIR BID AND WILL BE HANDLED VIA CHANGE ORDER AFTER SITE EVALUATION IS DONE BY WINNING BIDDER. CONTRACTOR SHALL FORWARD THE EVALUATION AND PRICE QUOTE TO THE CONSTRUCTION PM FOR APPROVAL PRIOR TO PERFORMING ANY AND ALL WORK.
AutoCAD SHX Text
CONTRACTOR SHALL VERIFY WITH DOLLAR TREE CONSTRUCTION PROJECT MANAGER ANY PROPOSED CUSTOM INTERIOR WINDOW GRAPHICS/FILM PRIOR TO BUILDING INFILL WALL AT STOREFRONT.
AutoCAD SHX Text
EXPIRES 12/31/20
AutoCAD SHX Text
LIC. # 9222
AutoCAD SHX Text
KRISTEN M. MACK
AutoCAD SHX Text
EXISTING EIFS
AutoCAD SHX Text
EXIST. FIN. FL. EL. 0'-0"
AutoCAD SHX Text
B.O. CANOPY 10'-1"±
AutoCAD SHX Text
T.O. PARAPET 23'-1 1/2"±
AutoCAD SHX Text
T.O. PARAPET 28'-4 3/4"±
AutoCAD SHX Text
T.O. ROOF DECK 22'-5 1/2"±
AutoCAD SHX Text
EXISTING EIFS
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
VINYL BASE
AutoCAD SHX Text
T
AutoCAD SHX Text
BALLOON CENTER
AutoCAD SHX Text
BALLOON CORRAL
AutoCAD SHX Text
SLATWALL TO 8'-0" AFF. PROVIDE 1X4 WOOD TRIM AT EDGES, PAINT WHITE (TYP).
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
GRAPHICS TENANT SUPPLIED
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
WALL SURFACE AREAS NOT COVERED BY GONDOLA UNITS SHALL BE PAINTED YELLOW.
AutoCAD SHX Text
2X4 HORIZONTAL WD BLOCKING EXTENDS TO FARTHEST OUTER EDGE OF LAST GONDOLA (REFER TO TENANT'S FIXTURE PLAN.)
AutoCAD SHX Text
NOTE: T= TEMPERED GLASS PER DOLLAR TREE REQUIREMENTS.
AutoCAD SHX Text
TOP OF PERIMETER WALL GONDOLA (TYP).
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
CORNER BOX (TYP.)
AutoCAD SHX Text
CORNER BOX (TYP.)
AutoCAD SHX Text
PROVIDE VINYL BASE ON WALL SURFACES NOT COVERED BY GONDOLA UNITS (TYP).
AutoCAD SHX Text
ELIASON DOOR - SEE DOOR SCHEDULE
AutoCAD SHX Text
TOP OF PERIMETER WALL GONDOLA (TYP).
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
2X4 HORIZONTAL WD BLOCKING EXTENDS TO FARTHEST OUTER EDGE OF LAST GONDOLA (REFER TO TENANT'S FIXTURE PLAN.)
AutoCAD SHX Text
WALL SURFACE AREAS NOT COVERED BY GONDOLA UNITS SHALL BE PAINTED YELLOW.
AutoCAD SHX Text
CORNER BOX (TYP.)
AutoCAD SHX Text
GRAPHICS TENANT SUPPLIED
AutoCAD SHX Text
1
AutoCAD SHX Text
A4
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
CORNER BOX (TYP.)
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
CORNER BOX (TYP.)
AutoCAD SHX Text
EMERGENCY
AutoCAD SHX Text
EXIT ONLY
AutoCAD SHX Text
WALL SURFACES COVERED BY FREEZERS AND COOLERS SHALL NOT BE PAINTED
AutoCAD SHX Text
FREEZER / COOLER
AutoCAD SHX Text
CORNER BOX (TYP.)
AutoCAD SHX Text
TOP OF PERIMETER WALL GONDOLA (TYP).
AutoCAD SHX Text
2X4 HORIZONTAL WD BLOCKING EXTENDS TO FARTHEST OUTER EDGE OF LAST GONDOLA (REFER TO TENANT'S FIXTURE PLAN.)
AutoCAD SHX Text
10
AutoCAD SHX Text
A4
AutoCAD SHX Text
WALL SURFACE AREAS NOT COVERED BY GONDOLA UNITS SHALL BE PAINTED YELLOW.
AutoCAD SHX Text
T
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
CORNER BOX (TYP.)
AutoCAD SHX Text
TOP OF PERIMETER WALL GONDOLA (TYP).
AutoCAD SHX Text
2X4 HORIZONTAL WD BLOCKING EXTENDS TO FARTHEST OUTER EDGE OF LAST GONDOLA (REFER TO TENANT'S FIXTURE PLAN.)
AutoCAD SHX Text
WALL SURFACE AREAS NOT COVERED BY GONDOLA UNITS SHALL BE PAINTED YELLOW.
AutoCAD SHX Text
E
AutoCAD SHX Text
A4.3
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
NOTE: T= TEMPERED GLASS PER DOLLAR TREE REQUIREMENTS.
AutoCAD SHX Text
PROVIDE VINYL BASE ON WALL SURFACES NOT COVERED BY GONDOLA UNITS (TYP).
AutoCAD SHX Text
SIGN MANUFACTURER TO VERIFY ELEVATION WITH LANDLORDS ARCHITECT.
AutoCAD SHX Text
EXTERIOR ELEVATIONS SHOWN FOR REFERENCE ONLY. WORK NOT IN CONTRACT.
AutoCAD SHX Text
AREA OF EXTERIOR SIGNAGE - REFER TO SIGN VENDOR'S DRAWINGS FOR PAINT & DETAILS.
AutoCAD SHX Text
EXISTING GLASS & ALUM. STOREFRONT
AutoCAD SHX Text
PROVIDE OPAQUE VINYL FILM ON INTERIOR FACE OF GLASS PRIOR TO INSTALLING INFILL WALL.
AutoCAD SHX Text
NEW GLASS & ALUM. STOREFRONT
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
EXPANSION SPACE
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
ADJACENT TENANT
AutoCAD SHX Text
EXPANSION SPACE
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
EXISTING BLACK FILM ON INTERIOR OF GLAZING TO REMAIN. NEW FILM TO BE APPLIED TO EXTERIOR FACE OF GLAZING BY TENANT.
AutoCAD SHX Text
EXISTING ALUM./GLASS DOORS, REMOVE EGRESS HARDWARE COMPLETE AND LOCK IN CLOSED POSITION. COVER HOLES AS REQUIRED.
AutoCAD SHX Text
EXISTING ALUM./GLASS DOORS, REMOVE EGRESS HARDWARE COMPLETE AND LOCK IN CLOSED POSITION. COVER HOLES AS REQUIRED.
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
03/04/20
AutoCAD SHX Text
TAW
AutoCAD SHX Text
CLARIFICATIONS
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
EXTERIOR FACADE TO BE POWER WASHED AND CLEANED TO LIKE NEW CONDITIONS.
AutoCAD SHX Text
R
AutoCAD SHX Text
1
Page 7: T: 314.821.1100 12 Sunnen Drive, Suite 100, St. Louis, MO ...summitgc.net/wp-content/uploads/2020/02/Revision-1-Walker-LA-03-04-20.pdf6. all materials indicated are new, unless specifically

12 S

unne

n Dr

ive,

Sui

te 1

00, S

t. Lo

uis,

MO

631

43T:

314

.821

.110

0

7'-6

1

/2

"

AutoCAD SHX Text
A4
AutoCAD SHX Text
DETAILS, SECTIONS & SCHEDULES
AutoCAD SHX Text
RBM
AutoCAD SHX Text
TAW
AutoCAD SHX Text
TAW
AutoCAD SHX Text
project
AutoCAD SHX Text
drawing
AutoCAD SHX Text
project
AutoCAD SHX Text
date
AutoCAD SHX Text
designed
AutoCAD SHX Text
drawn
AutoCAD SHX Text
checked
AutoCAD SHX Text
mark
AutoCAD SHX Text
revisions
AutoCAD SHX Text
date
AutoCAD SHX Text
by
AutoCAD SHX Text
description
AutoCAD SHX Text
PHONE: 314-821-1100
AutoCAD SHX Text
DOLLAR TREE
AutoCAD SHX Text
WALKER PLAZA
AutoCAD SHX Text
28050 WALKER ROAD SOUTH, WALKER, LA 70785
AutoCAD SHX Text
520574
AutoCAD SHX Text
02/25/20
AutoCAD SHX Text
PROFESSIONAL OF RECORD
AutoCAD SHX Text
CASCO DIVERSIFIED CORPORATION ARCHITECTURAL FIRM LICENSE #AE0220 EXPIRES 6/30/20
AutoCAD SHX Text
%%USALES AREA
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTRUCTION TYPE 2 & 7
AutoCAD SHX Text
WALL SECTION -
AutoCAD SHX Text
1"=1'-0"
AutoCAD SHX Text
9
AutoCAD SHX Text
A4
AutoCAD SHX Text
METAL STUD AND GWB PARTITION, WALL CONSTRUCTION TYPE:
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
2
AutoCAD SHX Text
TENANT'S FINISHED FLOOR/EXISTING SLAB
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
1 1/2"=1'-0"
AutoCAD SHX Text
7
AutoCAD SHX Text
A4
AutoCAD SHX Text
5/8" GWB ON 3 5/8" (20 GAUGE) MTL STUDS @ 12" OC
AutoCAD SHX Text
1X2 BLOCKING
AutoCAD SHX Text
VINYL "J" MOLD
AutoCAD SHX Text
CONTINUOUS SEALANT
AutoCAD SHX Text
PROVIDE OPAQUE WINDOW FILM ON INTERIOR FACE OF GLASS PRIOR TO INSTALLING INFILL WALL.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTRUCTION TYPE 1
AutoCAD SHX Text
WALL SECTION -
AutoCAD SHX Text
1"=1'-0"
AutoCAD SHX Text
10
AutoCAD SHX Text
A4
AutoCAD SHX Text
WALL CONSTRUCTION TYPE:
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
%%USALES AREA
AutoCAD SHX Text
1
AutoCAD SHX Text
TENANT'S FINISHED FLOOR/EXISTING SLAB
AutoCAD SHX Text
6" METAL STUDS @ 16" O.C. (SEE TABLE FOR MORE INFO.)
AutoCAD SHX Text
(2) BLOCKS PER BRACING STUD (ONE @ EA. END) W/ (3) #8 SMS FROM STUD & (3) #8 SMS FROM GYP. BOARD (6 TOTAL PER BLOCK)
AutoCAD SHX Text
3 5/8" x 20ga. CONT. BRACING STUD W/ (2) #8 SMS @ EA. STUD (SEE TABLE FOR REQUIRED LOCATIONS)
AutoCAD SHX Text
2" STUD WEB LAP, TYP.
AutoCAD SHX Text
(3) #12 SMS, TYP.
AutoCAD SHX Text
SEE TYP. ROOF DECK CONNECTION DETAIL 2/A4 FOR MORE INFO
AutoCAD SHX Text
EQ.
AutoCAD SHX Text
EQ.
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
SLAB
AutoCAD SHX Text
SLAB
AutoCAD SHX Text
SLAB
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
(E) SLAB
AutoCAD SHX Text
(E) ROOF DECK
AutoCAD SHX Text
3 5/8" x 20ga. CONT. BRACING STUD W/ (2) #8 SMS @ EA. STUD (SEE TABLE FOR REQUIRED BRACING STUD LOCATIONS)
AutoCAD SHX Text
GYP. BOARD - SEE TYPICAL DETAILS FOR MORE INFO.
AutoCAD SHX Text
HILTI X-U (.157" ) SHOT PINS W/ 1 1/4" EMBED INTO THE SLAB @ 4' O.C. & 4" OFF EACH END OF THE INDIVIDUAL PIECE OF TRACK, TYP.
AutoCAD SHX Text
STOCKROOM SIDE GYP. BOARD STOPS HERE & SALES FLOOR SIDE GYP. BOARD IS FULL HEIGHT AS SHOWN
AutoCAD SHX Text
SLAB
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
6" METAL STUDS @ 16" O.C. (SEE TABLE FOR MORE INFO.)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
WALL SECTION - CONSTRUCTION TYPE 3
AutoCAD SHX Text
1"=1'-0"
AutoCAD SHX Text
1
AutoCAD SHX Text
A4
AutoCAD SHX Text
A
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
BRACING ELEVATION
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
E
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
B
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
A
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
3
AutoCAD SHX Text
METAL STUD AND GWB PARTITION, WALL CONSTRUCTION TYPE:
AutoCAD SHX Text
2
AutoCAD SHX Text
A4
AutoCAD SHX Text
(2) 20 GA METAL STUD BLOCKS PER INDIVIDUAL BRACING STUD (ONE @ EA END) W/ (3) #8 SMS FROM STUD & (3) #8 SMS FROM GYPBOARD (6 TOTAL PER BLOCK) - LOCATE BLOCKS AT EACH SIDE OF SPLICE.
AutoCAD SHX Text
STUD SPAN
AutoCAD SHX Text
BRACE SPACING
AutoCAD SHX Text
BRACING LOCATION SECTION
AutoCAD SHX Text
NO BRACING REQUIRED
AutoCAD SHX Text
STUD GAGE
AutoCAD SHX Text
STUDS MUST MEET MINUMIM SSMA SPECIFICATIONS FOR 600S125 Fy=33 KSI STUDS OF THE SPECIFIED GAGE.
AutoCAD SHX Text
18'
AutoCAD SHX Text
20 (600S125-33)
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
5' OC (MAX)
AutoCAD SHX Text
20 (600S125-33)
AutoCAD SHX Text
22'
AutoCAD SHX Text
24'-6"
AutoCAD SHX Text
20 (600S125-33)
AutoCAD SHX Text
4'-2" OC (MAX)
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
3'-7" OC (MAX)
AutoCAD SHX Text
18 (600S125-43)
AutoCAD SHX Text
30'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JAMB DETAIL
AutoCAD SHX Text
HEAD /
AutoCAD SHX Text
1 1/2"=1'-0"
AutoCAD SHX Text
4
AutoCAD SHX Text
A4
AutoCAD SHX Text
SEE FLOOR PLAN FOR WALL CONSTRUCTION TYPE.
AutoCAD SHX Text
PROVIDE DOUBLE FRAMING AT HEAD & JAMB.
AutoCAD SHX Text
WOOD BLOCKING
AutoCAD SHX Text
CONTINUOUS SEALANT - BOTH SIDES
AutoCAD SHX Text
HOLLOW METAL DOOR FRAME W/ JAMB ANCHOR - 3 PER JAMB
AutoCAD SHX Text
DOOR AS SCHEDULED
AutoCAD SHX Text
PROVIDE GRILLES FOR VENTILATION AS REQUIRED - AMERICAN GRILLE AG10 OR EQUAL.
AutoCAD SHX Text
SUSPENDED ACOUSTICAL CEILING TILE - REFER TO REFLECTED CEILING PLAN FOR HEIGHT
AutoCAD SHX Text
(20 GA) SILL TRACK W/ "HILTI" SHOT PIN "DN" SERIES #X-DNI EMDED 1 1/4" X .145" DIA @ 16" OC (OR EQUAL)
AutoCAD SHX Text
4" VINYL BASE, REFER TO FINISH SCHEDULE, SHEET A4
AutoCAD SHX Text
CONTACT DOLLAR TREE'S CONSTRUCTION PM FOR GRAPHICS INFORMATION PRIOR TO INSTALLING INFILL WALL.
AutoCAD SHX Text
TENANT'S FINISHED FLOOR
AutoCAD SHX Text
PAINT YELLOW @ SALES AREA
AutoCAD SHX Text
EXISTING ALUM STOREFRONT SYSTEM
AutoCAD SHX Text
%%USALES AREA / OFFICE/PRE-SALES
AutoCAD SHX Text
PROVIDE ONE LAYER 5/8" GWB ON 3 5/8" MTL. STUDS @ 16" O.C.
AutoCAD SHX Text
BRACE TO STRUCTURE ABOVE.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTRUCTION TYPE 9
AutoCAD SHX Text
WALL SECTION -
AutoCAD SHX Text
3/4"=1'-0"
AutoCAD SHX Text
11
AutoCAD SHX Text
A4
AutoCAD SHX Text
11'-0" AFF
AutoCAD SHX Text
PAINT WHITE @ OFFICE
AutoCAD SHX Text
WALL CONSTRUCTION TYPE:
AutoCAD SHX Text
9
AutoCAD SHX Text
NO PAINT @ PRE-SALES
AutoCAD SHX Text
7
AutoCAD SHX Text
SUSPENDED ACOUSTICAL CEILING TILE - REFER TO REFLECTED CEILING PLAN FOR HEIGHT
AutoCAD SHX Text
NOTE: REFER TO TYPICAL REFER TO TYPICAL FIXTURE ATTACHMENT DETAIL
AutoCAD SHX Text
NOTE: ATTACH GONDOLA FIXTURE UNITS PER MANUFACTURER'S INSTRUCTIONS.
AutoCAD SHX Text
SUSPENDED ACOUSTICAL CEILING TILE - REFER TO REFLECTED CEILING PLAN FOR HEIGHT
AutoCAD SHX Text
(20 GA) SILL TRACK W/ "HILTI" SHOT PIN "DN" SERIES #X-DNI EMDED 1 1/4" X .145" DIA @ 16" OC (OR EQUAL)
AutoCAD SHX Text
1. THRESHOLDS AT EGRESS DOORS SHALL BE THRESHOLDS AT EGRESS DOORS SHALL BE NO MORE THAN 1/2" (MAX) HEIGHT AFF. 2. ALL DOOR HANDLES, PULLS, LATCHES, LOCKS ALL DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34" (MIN) TO 48" (MAX) AFF AND SHALL BE "SINGLE-HANDED" OPERABLE WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE. 3. WHERE EGRESS DOORS ARE USED IN PAIRS, WHERE EGRESS DOORS ARE USED IN PAIRS, THE UNLATCHING OF THE LEAF SHALL NOT REQUIRE MORE THAN ONE (1) OPERATION AS MENTIONED IN GENERAL HARDWARE NOTE #2 ABOVE. 4. CONTROLS AND OPERATING MECHANISMS CONTROLS AND OPERATING MECHANISMS SHALL BE LEVER-TYPE (OR EQUAL) PROVIDING OPERATION WITH ONE HAND AND NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS OF INTERIOR HINGED DOORS SHALL BE NO GREATER THAN 5 POUNDS (22.2 N). 5. DOORS EQUIPPED WITH CLOSERS SHALL BE DOORS EQUIPPED WITH CLOSERS SHALL BE ADJUSTED SO THAT THE SWEEP PERIOD FROM AN OPEN POSITION OF 70 DEGREES WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3" FROM THE LATCH, MEASURED FROM THE LEADING EDGE OF THE DOOR.
AutoCAD SHX Text
FINISH SCHEDULE
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
SPACES
AutoCAD SHX Text
FLOORS
AutoCAD SHX Text
BASES
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
CEILINGS
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
ENTRY CARPET TILE / POLISHED CONCRETE
AutoCAD SHX Text
4" VINYL
AutoCAD SHX Text
EXIST. GWB - PAINT YELLOW / FRP
AutoCAD SHX Text
ACT
AutoCAD SHX Text
1,2,4,5,6,9,11,13,14
AutoCAD SHX Text
SALES
AutoCAD SHX Text
PRE-SALES
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
HALLWAY
AutoCAD SHX Text
EMPLOYEE AREA
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
----
AutoCAD SHX Text
EXIST. GWB
AutoCAD SHX Text
----
AutoCAD SHX Text
2,8,11,16,17
AutoCAD SHX Text
POLISHED CONCRETE
AutoCAD SHX Text
4" VINYL
AutoCAD SHX Text
GWB - PAINT WHITE
AutoCAD SHX Text
----
AutoCAD SHX Text
2,5,6,9,10,13,14
AutoCAD SHX Text
EXIST. VCT
AutoCAD SHX Text
SHEET VINYL 6" HIGH
AutoCAD SHX Text
WR GWB W/ WHITE FRP
AutoCAD SHX Text
WR GWB - PAINT WHITE
AutoCAD SHX Text
6,7,11,12
AutoCAD SHX Text
POLISHED CONCRETE
AutoCAD SHX Text
4" VINYL
AutoCAD SHX Text
GWB - PAINT WHITE / FRP
AutoCAD SHX Text
ACT
AutoCAD SHX Text
2,4,6,7,11,13,14
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
----
AutoCAD SHX Text
FR PLYWOOD - PAINT GREEN
AutoCAD SHX Text
----
AutoCAD SHX Text
2,6,8,15,17
AutoCAD SHX Text
DOORS
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
FR
AutoCAD SHX Text
HDW NOTES
AutoCAD SHX Text
DOOR NOTES
AutoCAD SHX Text
#
AutoCAD SHX Text
W
AutoCAD SHX Text
H
AutoCAD SHX Text
T
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
SILL
AutoCAD SHX Text
100
AutoCAD SHX Text
3'-0"
AutoCAD SHX Text
6'-8"
AutoCAD SHX Text
1 3/4"
AutoCAD SHX Text
SOLID CORE WOOD
AutoCAD SHX Text
4/A4
AutoCAD SHX Text
--
AutoCAD SHX Text
100A
AutoCAD SHX Text
5,10,11,14
AutoCAD SHX Text
200
AutoCAD SHX Text
PR 3'-0"
AutoCAD SHX Text
300
AutoCAD SHX Text
400
AutoCAD SHX Text
401
AutoCAD SHX Text
500
AutoCAD SHX Text
3'-0"
AutoCAD SHX Text
3'-0"
AutoCAD SHX Text
PR 3'-0"
AutoCAD SHX Text
PR 3'-0"
AutoCAD SHX Text
6'-8"
AutoCAD SHX Text
7'-0"
AutoCAD SHX Text
7'-0"
AutoCAD SHX Text
7'-0"
AutoCAD SHX Text
7'-0"
AutoCAD SHX Text
0.063"
AutoCAD SHX Text
1 3/4"
AutoCAD SHX Text
1 3/4"
AutoCAD SHX Text
1 3/4"
AutoCAD SHX Text
1 3/4"
AutoCAD SHX Text
TEMP. ALUM ALLOY
AutoCAD SHX Text
SOLID CORE WOOD
AutoCAD SHX Text
EXIST HOLLOW MTL
AutoCAD SHX Text
EXIST HOLLOW MTL
AutoCAD SHX Text
NEW ALUM/GLASS
AutoCAD SHX Text
5/A4
AutoCAD SHX Text
4/A4
AutoCAD SHX Text
4/A4
AutoCAD SHX Text
5/A4
AutoCAD SHX Text
4/A4
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
--
AutoCAD SHX Text
200A
AutoCAD SHX Text
300A
AutoCAD SHX Text
400A
AutoCAD SHX Text
401C
AutoCAD SHX Text
500A
AutoCAD SHX Text
2,5,7,9,10,11,14
AutoCAD SHX Text
5,6,10,11,14,15
AutoCAD SHX Text
3,4,5,8,10,11,12,14
AutoCAD SHX Text
3,5,8,10,11,12,14
AutoCAD SHX Text
1,3,10,11,13,14
AutoCAD SHX Text
FINISH NOTES
AutoCAD SHX Text
FINISH NOTES
AutoCAD SHX Text
GENERAL HARDWARE NOTES
AutoCAD SHX Text
3/4" SLATWALL ON GWB
AutoCAD SHX Text
PROVIDE FRP OUTSIDE CORNER - WHITE.
AutoCAD SHX Text
5/8" GWB - PAINT YELLOW
AutoCAD SHX Text
6
AutoCAD SHX Text
A4
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
1 1/2"=1'-0"
AutoCAD SHX Text
12
AutoCAD SHX Text
A4
AutoCAD SHX Text
FINISHED FLOOR.
AutoCAD SHX Text
8'-0" A.F.F.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CEILING DETAIL @ TOILET
AutoCAD SHX Text
1 1/2"=1'-0"
AutoCAD SHX Text
ATTACHED WITH (2)-#12 TEK SCREWS AT EACH STUD.
AutoCAD SHX Text
GWB ON METAL STUDS. REFER TO SHEET A1 FOR WALL TYPES.
AutoCAD SHX Text
BASE. REFER TO FINISH SCHEDULE, SHEET A4 (TYP.)
AutoCAD SHX Text
3 5/8" (20 GAUGE) METAL STUDS @ 16" oc. W/ ONE LAYER 5/8" WR GWB. MAX STUD SPAN W/ DEFLECTION OF L/360 W/ MAX LOAD OF 5 PSF. ALIGN WITH WALL STUDS.
AutoCAD SHX Text
WATER RESISTANT GWB ON METAL STUDS. REFER TO SHEET A1 FOR WALL TYPES.
AutoCAD SHX Text
HILTI X-U (.157" ) SHOT PINS W/1 1 /4" EMBED INTO THE SLAB @ 4' O.C. & 4" OFF EACH END OF INDIVIDUAL PIECE OF TRACK, TYP.
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
NOTE: 1. REFER TO FINISH SCHEDULE FOR ALL FINISHES, SHEET A4
AutoCAD SHX Text
ROOF STRUCTURE
AutoCAD SHX Text
2X FIRE TREATED WOOD BLOCKING
AutoCAD SHX Text
2X FIRE TREATED WOOD BLOCKING
AutoCAD SHX Text
ONE-WAY VISION TEMPERED MIRROR GLASS
AutoCAD SHX Text
WOOD TRIM - PAINT WHITE. (MITER CORNERS)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
HEAD / JAMB DETAIL
AutoCAD SHX Text
1 1/2"=1'-0"
AutoCAD SHX Text
PROVIDE CORNER BEAD
AutoCAD SHX Text
%%UOFFICE
AutoCAD SHX Text
PAINT OFFICE INTERIOR WHITE.
AutoCAD SHX Text
%%USALES AREA
AutoCAD SHX Text
6'-5"
AutoCAD SHX Text
8'-0"
AutoCAD SHX Text
3
AutoCAD SHX Text
A4
AutoCAD SHX Text
1X4 POPLAR WD TRIM - PAINT WHITE
AutoCAD SHX Text
PAINT YELLOW
AutoCAD SHX Text
ONE LAYER 5/8" GWB EACH SIDE ON 3 5/8" (20 GA) METAL STUDS AT 16" OC.
AutoCAD SHX Text
1X4 POPLAR WD TRIM - PAINT WHITE
AutoCAD SHX Text
PROVIDE OPAQUE WINDOW FILM ON INTERIOR FACE OF GLASS PRIOR TO INSTALLING INFILL WALL.
AutoCAD SHX Text
FACE OF WALL - SEE WALL CONSTRUCTION TYPES FOR ADDITIONAL INFO.
AutoCAD SHX Text
MASONRY - USE HILTI 1/4" X 4" - USE HILTI 1/4" X 4" KWIK-CON II FASTENERS AT 24" OC.
AutoCAD SHX Text
SLAB AND TENANT FLOOR FINISH
AutoCAD SHX Text
%%USALES AREA
AutoCAD SHX Text
METAL OR WOOD STUDS - USE 1/4" - USE 1/4" X 4" ZINC COATED TEK SELF DRILLING SCREWS AT EACH STUD.
AutoCAD SHX Text
CONTRACTOR SHALL PROVIDE AND INSTALL 2X4 WD STUDS AS SHOWN AND ATTACH TO FACE OF WALL AS REQUIRED.
AutoCAD SHX Text
CONTRACTOR SHALL PROVIDE AND INSTALL 1X4 WD TRIM AT EXPOSED SIDES OF GONDOLA. ATTACHED TO 2X4 STUDS. PAINT WHITE.
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text
GONDOLA FIXTURE SUPPLIED BY TENANT AND INSTALLED BY CONTRACTOR PER MANUF PUBLISHED STANDARDS (TYP). PROVIDE BOLTS IN UPRIGHTS AT 4th HOLE FROM BOTTOM AND 6th HOLE FROM THE TOP.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
ATTACHMENT DETAIL
AutoCAD SHX Text
TYPICAL FIXTURE
AutoCAD SHX Text
1"=1'-0"
AutoCAD SHX Text
8
AutoCAD SHX Text
A4
AutoCAD SHX Text
AutoCAD SHX Text
1. CARPET TILE: MANUFACTURED BY INTERFACE FLOORING CARPET TILE: MANUFACTURED BY INTERFACE FLOORING SYSTEMS AND SUPPLIED BY TENANT. INSTALL TILES QUARTER TURNED AND PER TENANT'S CRITERIA. ENTRY TILE: DECO RIB, STYLE #678609900 TENANT'S CONTRACTOR SHALL PREPARE FLOOR SURFACE AND COORDINATE CARPET INSTALLATION W/ CARPET INSTALLER. 2. VINYL COVE BASE: COLOR - BLACK. (VINYL BASE ONLY VINYL COVE BASE: COLOR - BLACK. (VINYL BASE ONLY ON EXPOSED WALLS NOT COVERED BY GONDOLA IN SALES AREA). COVE BASE TO BE INSTALLED AT MOP SINK ONLY IN THE STOCKROOM, U.N.O. 3. LVT (LUXURY VINYL TILE) - SUPPLIED BY TENANT & LVT (LUXURY VINYL TILE) - SUPPLIED BY TENANT & INSTALLED BY CONTRACTOR. 4. PROVIDE 2'-0" X 4'-0" CEILING TILE EQUAL TO PROVIDE 2'-0" X 4'-0" CEILING TILE EQUAL TO ARMSTRONG "CORTEGA" MINABOARD #769, WHITE, IN A WHITE METAL GRID. (IN AREAS W/ SIGNIFICANT AIR PRESSURE DIFFERENTIALS PROVIDE RETENTION CLIPS TO RETAIN PANELS IN PLACE.) REFER TO SHEET A2 FOR HEIGHT. 5. SLATWALL: 3/4" SLATWALL W/ WHITE MELAMINE FINISH. SLATWALL: 3/4" SLATWALL W/ WHITE MELAMINE FINISH. SEE MANUFACTURER'S DRAWINGS FOR INSTALLATION DETAILS. 6. PAINT COLORS ARE AS FOLLOWS: PAINT COLORS ARE AS FOLLOWS: WHITE - SHERWIN WILLIAMS PRO 200 LATEX - SHERWIN WILLIAMS PRO 200 LATEX SEMI-GLOSS WHITE W/ B-1 PER GALLON. YELLOW - "LEMON SORBET" #2019-60. BENJAMIN - "LEMON SORBET" #2019-60. BENJAMIN MOORE PRODUCT 274 EGGSHELL FINISH GREEN - "FOREST GREEN" #2047-10. BENJAMIN - "FOREST GREEN" #2047-10. BENJAMIN MOORE PRODUCT 274 EGGSHELL FINISH (EMPLOYEE ROOM WALLS ONLY) GREEN - "ENVY GREEN" SW6925LRV 18% SHERWIN - "ENVY GREEN" SW6925LRV 18% SHERWIN WILLIAMS TAN - "TRUSTY TAN" #6087. BENJAMIN MOORE - "TRUSTY TAN" #6087. BENJAMIN MOORE PRODUCT 274 EGGSHELL FINISH (SALES FLOOR 12'-0" AFF AND HIGHER) (IF SALES FLOOR HAS OPEN CEILING) 7. PAINT TOILET ROOM INTERIOR CEILING WHITE AND PAINT TOILET ROOM INTERIOR CEILING WHITE AND EXTERIOR HALLWAY WALLS WHITE. 8. EXISTING CONCRETE FLOOR TO REMAIN. PATCH AND EXISTING CONCRETE FLOOR TO REMAIN. PATCH AND REPAIR AS REQUIRED TO PROVIDE SMOOTH SURFACE. 9. SLATWALL SHALL BE PROVIDED BY TENANT AND SLATWALL SHALL BE PROVIDED BY TENANT AND INSTALLED BY TENANT'S CONTRACTOR. ALL OTHER FINISHES SHALL BE PROVIDED AND INSTALLED BY TENANT'S CONTRACTOR. 10. PROVIDE PREFORMED COUNTER W/ WHITE HIGH PROVIDE PREFORMED COUNTER W/ WHITE HIGH PRESSURE LAMINATE FINISH. MOUNT TO WALLS. FILING CABINETS PROVIDED BY TENANT. SEE ENLARGED OFFICE PLAN AND OFFICE ELEVATION. 11. F R P (FIBERGLASS REINFORCED PANEL): IN TOILET F R P (FIBERGLASS REINFORCED PANEL): IN TOILET ROOM FROM FLOOR TO 8'-0" AFF SHALL BE WHITE COLOR (IN STOCKROOM BEHIND MOP SINK AND UTILITY CABINET ONLY, IN HALLWAY BEHIND DRINKING FOUNTAIN ONLY). FRP ON SALES FLOOR (WHERE NOTED ON PLANS/ELEVATION SHALL BE ALMOND COLOR WITH "J" CHANNEL TRIM CAP AND "H" CHANNEL PANEL CONNECTORS. 12. SHEET VINYL: CLASSIC CORLON SERIES MANUFACTURED SHEET VINYL: CLASSIC CORLON SERIES MANUFACTURED BY ARMSTRONG - CONNECTION CORLON "PORCELAIN" #88724 OR EQUAL. SHEET VINYL BASE: BY INTEGRAL, 3/8" RADIUS, 6" HIGH COVED BASE W/ COVE STICK AND EXTRUDED ALUMINUM CAP TRIM. 13. POLISH CONCRETE FLOOR ON SALES FLOOR, HALLWAY POLISH CONCRETE FLOOR ON SALES FLOOR, HALLWAY AND OFFICE. POLISH CONCRETE FLOOR BY TENANT'S VENDOR. COORDINATE W/ TENANT. 14. SALES AREA TO RECEIVE LEVEL 5 FINISH. PROVIDE SALES AREA TO RECEIVE LEVEL 5 FINISH. PROVIDE FINISH TO 1'-0" BEHIND FREEZER/COOLER AND GONDOLA. TO FINISHED FLOOR EVERYWHERE ELSE. CONTRACTOR SHALL ALLOW 72 HOUR CURE TIME. 15. PAINT EMPLOYEE AREA WALLS TO 4'-0" AFF "FOREST PAINT EMPLOYEE AREA WALLS TO 4'-0" AFF "FOREST GREEN." 16. PAINT 6" WIDE BAND ON CONCRETE FLOOR AROUND PAINT 6" WIDE BAND ON CONCRETE FLOOR AROUND PERIMETER OF STOCKROOM WITH TWO COATS OF BENJAMIN MOORE "FD BM WHITE" TOUGH SHIELD ACRYLIC GLOSS TY-43. PAINT BAND PRIOR TO PAINTING ANY YELLOW CLEAR FLOOR SPACE AREAS. 17. CONTRACTOR SHALL SEAL CONCRETE FLOOR AND ADD CONTRACTOR SHALL SEAL CONCRETE FLOOR AND ADD VINYL COVE BASE AT ENTIRE PERIMETER OF PRE-SALES AND EMPLOYEE AREA. PRE-SALES WALLS TO BE PAINTED SEMI-GLOSS WHITE TO 8'-0".
AutoCAD SHX Text
1. PROVIDE A SIGN POSTED ON THE EGRESS SIDE, PROVIDE A SIGN POSTED ON THE EGRESS SIDE, ON OR ADJACENT TO THE DOOR STATING: "THIS "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." THE SIGN SHALL BE IN LETTERS 1" THE SIGN SHALL BE IN LETTERS 1" HIGH ON A CONTRASTING BACKGROUND. 2. NEW DOORS - SUPPLIED BY TENANT - ELIASON NEW DOORS - SUPPLIED BY TENANT - ELIASON - SUPPLIED BY TENANT - ELIASON BI-SWING DOORS W/ WINDOW. EXISTING DOORS - INSTALL ALUMINUM COVER - INSTALL ALUMINUM COVER PLATE (SUPPLIED BY TENANT) ON EXISTING DOORS TO REMAIN. 3. DOOR, FRAME AND HINGES ARE EXISTING. DOOR, FRAME AND HINGES ARE EXISTING. PROVIDE AND INSTALL ANY MISSING ITEMS OF HARDWARE PER HARDWARE NOTES. 4. PROVIDE (1) ONE PEEP HOLE TO VIEW OUT. MOUNT PROVIDE (1) ONE PEEP HOLE TO VIEW OUT. MOUNT @ 4'-3" AFF. 5. PAINT DOORS AND FRAMES W/ WHITE PAINT DOORS AND FRAMES W/ WHITE SEMI-GLOSS ENAMEL PAINT AT ALL INTERIOR SURFACES. EXTERIOR DOORS SHALL MATCH EXISTING BUILDING COLOR ON EXTERIOR SURFACES. 6. INSTALL TENANT SUPPLIED SIGNAGE PER DETAIL INSTALL TENANT SUPPLIED SIGNAGE PER DETAIL C/A4.1. 7. REINFORCE JAMBS W/ WOOD BLOCKING. REINFORCE JAMBS W/ WOOD BLOCKING. 8. INSTALL TENANT SUPPLIED SIGNAGE THAT READS INSTALL TENANT SUPPLIED SIGNAGE THAT READS "EMERGENCY EXIT ONLY." 9. INSTALL TENANT SUPPLIED SIGNAGE THAT READS INSTALL TENANT SUPPLIED SIGNAGE THAT READS "EMPLOYEES ONLY." 10. CONTROLS AND OPERATING MECHANISMS WILL CONTROLS AND OPERATING MECHANISMS WILL BE OPERABLE W/ ONE HAND AND NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 4 LBS. 11. PROVIDE HARDWARE TO COMPLY W/ ANSI, A117.1. PROVIDE HARDWARE TO COMPLY W/ ANSI, A117.1. 12. REFER TO DETAIL B/A4.1 FOR DOOR ALARM REFER TO DETAIL B/A4.1 FOR DOOR ALARM MOUNTING. 13. INSTALL SIGNAGE PER ELEVATION F/A3. INSTALL SIGNAGE PER ELEVATION F/A3. 14. LISTED HARDWARE PROVIDES GUIDELINES TO LISTED HARDWARE PROVIDES GUIDELINES TO LANDLORD AND CONTRACTOR PER CLIENTS DIRECTION. TENANT MUST PROVIDE HARDWARE THAT COMPLIES W/ ALL GOVERNING AUTHORITIES. 15. PROVIDE COAT HOOK @ 48" AFF ON BACK SIDE PROVIDE COAT HOOK @ 48" AFF ON BACK SIDE OF DOOR.
AutoCAD SHX Text
HDW # 100A 1 1/2 PAIR HINGES: STANDARD WEIGHT 1 MECHANICAL PUSH BUTTON LOCKSET WITH LEVER HANDLE 1 CLOSER 1 FLOOR STOP
AutoCAD SHX Text
HDW # 300A 1 1/2 PAIR HINGES: STANDARD WEIGHT 1 PRIVACY SET W/ LEVER HANDLE 1 CLOSER (FLOOR/WALL STOP IF SHIPPED WITH HARDWARE)
AutoCAD SHX Text
HDW # 400A 3 PAIR HINGES: 4 1/2" HEAVY WEIGHT, NON- REMOVABLE PINS 1 NON-ALARMED, NON-KEYED PANIC BAR DEVICE: WITH STAND ALONE ALARM REFER TO DOOR ALARM MOUNTING DETAIL 2 OVERHEAD HOLDERS/STOPS 2 FLUSH BOLTS (ON INACTIVE LEAF) 1 DUST PROOF STRIKE 1 PEEP HOLE 1 ALUM THRESHOLD (1/2" MAX HEIGHT) 2 SWEEPS 1 WEATHER STRIP 1 RAIN DRIP 1 ASTRAGAL
AutoCAD SHX Text
HDW # 401C 1 1/2 PAIR HINGES: STANDARD WEIGHT, NON- REMOVABLE PINS 1 NON-ALARMED, NON-KEYED PANIC BAR DEVICE: WITH STAND ALONE ALARM REFER TO DOOR ALARM MOUNTING DETAIL. 1 CLOSER WITH STOP ARM 1 ALUM THRESHOLD (1/2" MAX HEIGHT) 1 SWEEP 1 WEATHER STRIP 1 RAIN DRIP
AutoCAD SHX Text
HDW # 500A HINGES PER STOREFRONT MANUFACTURER (BY GENERAL CONTRACTOR) 2 CLOSERS WITH STOP ARM AND DROP PLATE 2 PUSH PLATES (BY GENERAL CONTRACTOR) 2 PULL HANDLES (BY GENERAL CONTRACTOR) 1 KABA CYLINDER (SUPPLIED BY TENANT) 1 COMMERCIAL GRADE DEADLOCK W/ THUMB TURN ON SALES SIDE (BY GENERAL CONTRACTOR)
AutoCAD SHX Text
HDW # 200A LWP-3 ALUMINUM TRAFFIC DOOR EASY SWING HINGE SYSTEM 9" X 30" CLEAR ACRYLIC WINDOW FLUSH HOLLOW METAL FRAME - DRYWALL
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JAMB DETAIL
AutoCAD SHX Text
HEAD /
AutoCAD SHX Text
1 1/2"=1'-0"
AutoCAD SHX Text
5
AutoCAD SHX Text
A4
AutoCAD SHX Text
SEE FLOOR PLAN FOR WALL CONSTRUCTION TYPE.
AutoCAD SHX Text
PROVIDE DOUBLE FRAMING AT HEAD & JAMB.
AutoCAD SHX Text
WOOD BLOCKING
AutoCAD SHX Text
CONTINUOUS SEALANT - BOTH SIDES
AutoCAD SHX Text
ELIASON BI-SWING DOOR AS SCHEDULED
AutoCAD SHX Text
FLUSH METAL FRAME BEYOND
AutoCAD SHX Text
EXPIRES 12/31/20
AutoCAD SHX Text
LIC. # 9222
AutoCAD SHX Text
KRISTEN M. MACK
AutoCAD SHX Text
1 1/2"x 16 GAUGE, COLD ROLLED U-CHANNEL BRIDGING NOT MORE THAN 12" FROM TOP OF WALL (TYP). ATTACH BRIDGING TO METAL STUDS WITH MANUFACTURED CLIP ANGLES. AT PARTITION TYPES
AutoCAD SHX Text
3
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
ROOF CONNECTION DETAIL
AutoCAD SHX Text
DEFLECTION TRACK
AutoCAD SHX Text
1"=1'-0"
AutoCAD SHX Text
2
AutoCAD SHX Text
A4
AutoCAD SHX Text
16 GA TRACK (W/ 3" DEEP LEGS) CONTINUOUS AT TOP OF SEPARATION WALLS W/ #12 TEKS @ 16" OC.
AutoCAD SHX Text
SEALANT OR SAFING INSULATION
AutoCAD SHX Text
EXISTING METAL DECK
AutoCAD SHX Text
CUT STUDS 1 1/2" SHORT
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
03/04/20
AutoCAD SHX Text
TAW
AutoCAD SHX Text
CLARIFICATIONS
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1
AutoCAD SHX Text
R
AutoCAD SHX Text
1