System Limits (Trunks)

22
1 DCNNG SA SD Design Calc ST/PRM3-EU | | 02.Mar.0 6 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems System Limits (Trunks) 1. Control facilities single CCU 245 addresses max. Delegate units, chairman's units, and interpreters desks are counting for 1. Channel selectors are passive units and using one reserved address for all. Reserved addresses are not a part of the 245! 2. Power handling Capacity Central Control Unit 130 Watt Extension Power Supply 255 Watt 3. Cable length After 100 meter of system cable the signal needs to be regenerated. Units with the regenerating signal-outlets: Trunk Splitter & Tap-Off unit (Trunk Splitter protected) Extension power supply (Tap-off outlets only) The number of serial tap-off connections from the CCU to the last tap-off in a branch must not exceed 4. 250 meter max. from the CCU to the last unit in the trunk. I&U Instruction s

description

System Limits (Trunks). 1. Control facilities single CCU 245 addresses max. Delegate units, chairman's units, and interpreters desks are counting for 1. Channel selectors are passive units and using one reserved address for all. Reserved addresses are not a part of the 245 ! - PowerPoint PPT Presentation

Transcript of System Limits (Trunks)

Page 1: System Limits  (Trunks)

1 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

System Limits (Trunks)

1. Control facilities single CCU 245 addresses max.

Delegate units, chairman's units, and interpreters desks are counting for 1. Channel selectors are passive units and using one reserved address for all.

Reserved addresses are not a part of the 245!

2. Power handling Capacity Central Control Unit 130 Watt Extension Power Supply 255 Watt

3. Cable length After 100 meter of system cable the signal needs to be regenerated.

Units with the regenerating signal-outlets: Trunk Splitter & Tap-Off unit (Trunk Splitter protected) Extension power supply (Tap-off outlets only)

The number of serial tap-off connections from the CCU to the last tap-off in a branch must not exceed 4.

250 meter max. from the CCU to the last unit in the trunk.

I&U Instructions

Page 2: System Limits  (Trunks)

2 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Discussion Unit with fixed microphone 2.75 W

Discussion Unit 2.75 W

Discussion Unit with Channel selector 2.9 W

Discussion Unit Dual 2.8 W

Discussion Unit Dual with channel selector 3.15 W

Discussion Unit with voting 3.05 W

Discussion Unit with voting and channel selector 3.20 W

Concentus Chairman unit 4.2 W

Concentus basic unit 3.4 W

Concentus with channel selector 3.7 W

Concentus full function 4.2 W

Voting Unit 1.0 W

Dual Delegate Interface 4.5 W Inclusive all connected FM panels.

Power Consumption in Watt

I&U Instructions

Page 3: System Limits  (Trunks)

3 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Interpreter’s Desk 3.6 W

Channel selector unit 0.9 W

Data distribution unit 2.0 W

Extension Power Supply 0.8 W

Trunk Splitter 1.3 W

Tap-Off Unit (Trunk Splitter Protected)

1.4 W

Watt value includes the 2 meter (6.5 ft.) unit-cable.

Audio Expander Analogue 7.6 W

Audio Expander Digital 6.0 W

Cobra net interface 10.5 W

Optical Network splitter 3.9 W

Fiber Interface (POF/GOF or GOF/POF) 4.6 W

Power Consumption in Watt

I&U Instructions

Page 4: System Limits  (Trunks)

4 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Power handling capacities

Central Control Unit Central Control Unit Extension Power SupplyDCN-CCUB DCN-CCU DCN-EPS

65 W 65 W

65 W 65 W

130 W

65 W

Trunk Tap-off

85 W 85 W

255 W

85 W

I&U Instructions

65 W 65 W

130 W

Page 5: System Limits  (Trunks)

5 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Max. number of units within 100M from CCU

Max. per trunk: 18 Interpreter desks 50 Channel selectors

or

Max. all trunks: 36 Interpreter desks 100 Channel selectors

or

Central Control Unit

Cable length per outlet to the last unit 100M

1 n 50

1 n 18

I&U Instructions

Page 6: System Limits  (Trunks)

6 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Max. number of units connected to the CCU

Max. per trunk: 18 Interpreter desks 70 Channel selectors

or

Max. all trunks: 36 Interpreter desks 140 Channel selectors

or

* * Max. Cable length 100m

Central Control Unit

1 n 18

* Tap-off outlets.Tap-off outlets.

1 5051 70TS

I&U Instructions

Page 7: System Limits  (Trunks)

7 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Max. number of units within 100M from EPS

Max. per trunk: 23 Interpreter desks 50 Channel selectors

or

Max. all trunks: 69 Interpreter desks150 Channel selectors

or

Trunk Tap-off

Cable length per outlet to the last unit 100M

Extension Power Supply

1 n 23

1 n 50

1 n 50

I&U Instructions

Page 8: System Limits  (Trunks)

8 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Max. number of units connected to the EPS

Max. per trunk: 23 Interpreter desks 90 Channel selectors

or

Max. all trunks: 69 Interpreter desks 270 Channel selectors

or

Trunk Tap-off

Extension Power Supply

1 5051 90

1 5051 90

1 n 23

Max. Cable length 100m

* Tap-off outlets.Tap-off outlets.

* *

* *

I&U Instructions

LBB4114

LBB4114

Page 9: System Limits  (Trunks)

9 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Trunk Outlet & Tap-Off Outlets

For Trunk-cable splitting with regenerating the digital signal.

*

Tap-off outlets which regenerating the digital signal.Tap-off outlets which regenerating the digital signal.

* *

Extension Power Supply

* *

Trunk-in Trunk-out

Trunk Splitter&

Tap-Off unit (trunk splitter

protected)

I&U Instructions

Page 10: System Limits  (Trunks)

10 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Using the Tap-Off unit (Trunk Splitter Protected)

* *

* Tap-off outlets with a limitation of 4,5 Watt.Tap-off outlets with a limitation of 4,5 Watt.

* *

I&U Instructions

LBB4115 LBB4115

Page 11: System Limits  (Trunks)

11 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Tap-Off Limitations

Trunk Splitter

Tap-off

Tap-off Trunk-lineLoop Through

Trunk-line

1st Tap-off

1st Tap-off

3rd Tap-off

2nd Tap-off

2nd Tap-off

3rd Tap-off

4th Tap-off

4th Tap-off

5th Tap-off

Extension Power SupplyCentral ControlUnit

I&U Instructions

Page 12: System Limits  (Trunks)

12 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Maximum Cable Lengths 250M

Central ControlUnit

RegenerativeTap-offTrunk Splitter

ExtensionPower Supply

RegenerativeTap-offTrunk Splitter

ExtensionPower Supply

I&U Instructions

Page 13: System Limits  (Trunks)

13 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Longest Extension Cable example

The length of cable used in a system hasa direct influence on the load of a

system.

The second in- line trunk- splitter has two extension cables connected to it, with lengths of 20 m and 50 m.

When determining the cable length of a Trunk-outlet or Tap-off outlet, the longest extension cable only is taken in to account.

Therefore, the total extension cable lengthfrom a single Trunk-outlet of the CCU is calculated as 10+50= 60 m (196.8 ft.)

10 m (32.8 ft.)

50 m (164 ft.)20 m (65.6 ft.)

Central ControlUnit

I&U Instructions

Page 14: System Limits  (Trunks)

14 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Power calculation Example-1

TrunkOutlet

Longest ExtensionCable length

Power consumptionwithout

ext. cable correction

Power consumption with

ext. cable correction

1 65 m. (213.2 ft.) 46.6 Watt 63.9 Watt

2 40 m. (147.4 ft.) 54.0 Watt 64.8 Watt

Total power in use 128.7 Watt

*

Max. Cable length 100m

Central Control Unit

12x 12x12x 12x

TS

10x 5x

40m.

50m.15m.

1 2

To EPSSee next slide

* TS

Example

LBB4114

Page 15: System Limits  (Trunks)

15 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Power calculation Example-2

TrunkOutlet

Longest ExtensionCable length

Power consumptionwithout

ext. cable correction

Power consumption with

ext. cable correction

3 60 m. (196.8 ft.) 63.4 Watt 84.5 Watt

4 40 m. (131.2 ft.) 70.6 Watt 84.7 Watt

5 35 m. (131.2 ft.) 72.0 Watt 84.3 Watt

Total power in use 253.5 Watt

Example

Trunk Tap-off

Extension Power Supply

10x 20x15x 24x

20x 20x22x 15x

10x35m.

10x

Max. Cable length 100m

* 40m.20m.

20m.20m.

TS

TS

3 4 5

*

LBB4114

LBB4114

Page 16: System Limits  (Trunks)

16 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Cable correction graph

I&U Instructions

Page 17: System Limits  (Trunks)

17 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

System Limits (Optical)

1. Maximum number of nodes is 63

2. Maximum number of optical devices is 16

3. Optical Plastic Fiber length is maximum 50 Meter

4. Maximum Optical cable length is depending of the number of nodes in the system

I&U Instructions

Page 18: System Limits  (Trunks)

18 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Basic Central Control Unit 0

Central Control Unit 2

Audio Expander LBB4402/00 1

Digital Audio Expander 1

CobraNet Interface 1

Optical Network Splitter 1

Fiber Interface POFGOF & GOFPOF 0

Integrus Transmitter 4 channels 1

Integrus Transmitter 8 channels 2

Integrus Transmitter 16 channels 4

Integrus Transmitter 32 channels 8

Number of nodes per optical unit

I&U Instructions

Page 19: System Limits  (Trunks)

19 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Fiber interface without address

The fiber interface is used to: convert from plastic optical fiber

(POF) cable to glass optical fiber (GOF) cable and vice versa.

cover distances of more than 50 m in the optical network.

I&U Instructions

LBB4414/10 LBB4414/10

Page 20: System Limits  (Trunks)

20 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Nodes Cable lengths graph

I&U Instructions

Page 21: System Limits  (Trunks)

21 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

Optical connections

I&U Instructions

CobraNet

Central Controle Unit

Interface

Audio Expander

Integrus Transmitter

Page 22: System Limits  (Trunks)

22 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of

disposal such as copying and passing on to third parties.

Security Systems

System Design and Calculation

End of section