System Compatibility - Salford Groupdealer.salfordgroup.com/uploads/userfiles/files... · John...
Transcript of System Compatibility - Salford Groupdealer.salfordgroup.com/uploads/userfiles/files... · John...
System Compatibility
Display Unlocks
1. Mueller Touch800 – Requires a TC upgrade for Prescription and a Section Control unlock
2. John Deere 2630 – Requires a Section Control unlock
3. Case IH Pro700 – Requires a TC unlock for Prescription and Section Control
4. AgLeader Integra – Requires a multi-product unlock for multi-bin Rate and Section Control
Part Number: Description:ME0502001-21 ISOBUS Harness, 21 ft.
MEXXXXXXX Dry Spreader ECUMExxxxxxxx Custom Machine Harness
Optional:ME0520000 Foot Pedal, remote master ME0520001 Foot Pedal, 15’ Extension
1
1
23
3
4
4
5
5
2
1
2
3
1Home Screen
1. Soft Key Display Area
2. Main Screen Actual and Target Rate Area
3. Main Screen Application Status Area
4. Main Screen Footer Area
2
3
4
Home Screen
1. Branding Logo – Used for other data when in work.
2. Actual/Target Application Rate Bin 1– units/area
3. Actual/Target Application Rate Bin 2 – units/area
4. Application Status – ON or OFF
5. Task is started, data being recorded through Task Controller
6. Spreader ON/OFF
7. Belt Speed for Bin 1
8. Ground speed
9. Belt Speed for Bin 2
10. Bin Level Graph and Amount remaining. Will be displayed
when the Master is ON.
1
2
3
4
5 6
6
8
7
11
9
10
1 2
3
4
5 6
7
Home Screen Soft Keys
1. Soft Key – Icon Indicates Information Screen. Press
Navigates to Information screen.
2. Soft Key – Icon Application Start/Stop. Press toggles
ON/OFF Application State. Note Icon will be updated with
status.
3. Soft Key – Icon Indicates Road Mode. Press toggles
ON/OFF Road Mode.
4. Soft Key – Icon Section On / Off.
5. Soft Key – Icon for Bin Fill/Product Management. Press
navigates to Tank Fill Screen.
6. Soft Key –Icon for Delta Rate Adjustment. Press enters delta
rate adjustment page for each bin.
7. Soft Key – Icon Indicates Settings Screens. Press navigates
to Setting Screens.
1
2
34
5
6
7
1
2
34
8
Setting Screen 1/2 Functions
1. Name of Product in associated bin
2. Default Target Rate for product in associated bin
3. Delta Rate for product in associated bin
4. Density of product in associated bin
5. Soft Key – Navigates to associated bin calibration
6. Soft Key – Disables bin, no product will apply
7. Soft Key – Icon Indicates another page of Soft Keys.
8. Soft Key – Press returns to previous screen.
1
2
3
4
5
6
7
8
9
Setting Screen 2/2 Functions
1. Min Speed Setting. If ground speed drops below this set
point, spreader application will stop.
2. Target RPM for Spinner.
3. Bin Selection for Gate Height entry value.
4. Cal Factor for Bin 1 and Bin 2 adjustment. 5 is default, 10 will
increase drive sensitivity, 0 will lower sensitivity to drive
control.
5. Soft Key – Navigates to speed source selection
6. Soft Key – Navigates to warning setup selections
7. Soft Key – Navigates to diagnostics page
8. Soft Key – Navigates to spreader geometry setup screen
9. Soft Key – Navigates to OEM locked screens
Geometry Setup
Setup the spreaders
geometry. These are the
values that will be sent to
display for mapping and
auto guidance functions.
Alarm Setup
Enable/Disable the alarms
needed.
Set threshold for each
alarm selected.
Speed Source SetupSelecting the speed source available
for the spreader to use for rate control.
Custom Configuration Setup
1. If check marked, Spinner will start and stop when
main belt/master is turned ON/OFF.
2. Number of bin level sensors for the associated bin
selected.
3. Option if external master switch is being used.
4. Soft Key – Navigates to OEM locked screen settings
1
2
3
4
OEM Password Settings
Filling Hopper Selection
1. Product Selected for associated Bin
2. Remaining Weight in Bin
3. Amount to add into associated bin
4. Succession or Bin Chaining setup
5. Soft Key - Bin 1 Filling Selection
6. Soft Key - Bin 2 Filling Selection
7. Soft Key - Product Management screen
8. Soft Key - Fills associated bin to max capacity
9. Soft Key - Empty's associated bin to 0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
Product Management
1. Current Product Selection
2. Selection to rename selected product
3. Bin selected product is calibrated against
4. Calibration values of product for associated bin
5. Soft Key – Icon to delete selected product.
Press activates popup to confirm deletion of
selected product
1
2
3
4
5
6
7
Target Rate Adjustment
1. Bin 1 Application control, and Target Rate
2. Bin 2 Application control, and Target Rate
3. Soft Key - Bin 1 Rate Increase by Delta Value
4. Soft Key - Bin 2 Rate Increase by Delta Value
5. Soft Key - All bins return to Default rate when pressed
6. Soft Key - Bin 1 Rate Decrease by Delta Value
7. Soft Key - Bin 2 Rate Decrease by Delta Value
Application Control
Options for each bin.
1
2
3
Prescription Setup
1. Product Default Rate greyed Out because
prescription is loaded and selected for use
2. If prescription is loaded, the operator has the
option to select the prescription for use for
the associated bin
3. Icon on the main page indicating bin is using
prescription rate
Product Calibration
Software Update Tools
Thank You for Your Attention
Questions?