8
TRACK TECHNICAL DETAILS and FITTING INSTRUCTIONS SYSTEM 16 CEILING 19mm 19mm Max 120cm Max 60cm Max 8cm Max 8cm 16mm 30mm Top fix only 10kg/m fixed at 60cm spacing directly into ceiling/topboard Top fix or face fix kg/m with standard brackets 15kg/m with heavy duty brackets SYSTEM 30 BENDABLE SYSTEM 30 STRAIGHT BRACKET SPACING BRACKET SPACING Max 60cm Max 60cm Top fix or face fix 10kg/m with brackets either side of every bend, max spacing 60cm 19mm 30mm * A bracket is required either side of every bend BRACKET SPACING * Two brackets are required at the track ends 1 Tel: 01404 47568 Email: [email protected] www.cameronfuller.co.uk © cameronfuller 2016 v1

Transcript of SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit...

Page 1: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

TRACK TECHNICAL DETAILS and FITTING INSTRUCTIONS

S Y S T E M 1 6 C E I L I N G

19mm

19mm

Max 120cm

Max 60cm

Max 8cm

Max 8cm

16mm

30mm

Top fix only 10kg/m fixed at 60cm spacing directly into ceiling/topboard

Top fix or face fixkg/m with standard brackets 15kg/m with heavy duty brackets

S Y S T E M 3 0 B E N D A B L E

S Y S T E M 3 0 S T R A I G H T

B R A C K E T S PA C I N G

B R A C K E T S PA C I N G

Max 60cmMax 60cm

Top fix or face fix10kg/m with brackets either side of every bend, max spacing 60cm

19mm

30mm

* A bracket is required either side of every bend

B R A C K E T S PA C I N G

* Two brackets are required at the track ends

1Tel: 01404 47568 Email: [email protected] www.cameronfuller.co.uk © cameronfuller 2016 v1

Page 2: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

S Y S T E M 1 6 C E I L I N G

S Y S T E M 3 0 S T R A I G H T

S Y S T E M 3 0 B E N D A B L E

Fit track directly to ceiling or top board, using pre-drilled holes

See page 8 for bracket sizes

See page 8 for bracket sizes

Fit track directly to ceiling / top board

Drill using drill guide and 4mm drill-bit (supplied) or order pre-drilled from us

No brackets required

Drill using drill guide and 4mm drill bit (supplied) or order pre-drilled from us

No brackets required

Not suitable for bending

TOP FIXING

TOP FIXING ONLY. NO FACE FIXING OPTION

Fit track directly to ceiling or top board, using pre-drilled holes

No brackets required

When top fixing bendable track, DO NOT over tighten screws as this can deform the track and cause the gliders to jam

TOP FIXING

IMPORTANT

FACE FIX BRACKETS FOR SYSTEM 30

FACE FIX BRACKETS FOR SYSTEM 30

Use pre-drilled holes

2

Front

Back

Front

Back

Page 3: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

Join using straight joiner

Magnet

Magnet

Magnet

Magnet

Magnet

Cover plate

S YS T E M 3 0 S T R A I G H T J O I N E R F I N I A L S

S YS T E M 3 0 B E N D A B L E J O I N E R

Ensure magnet is at the front of the track so that the cover plate will locate correctly

The finials below are for System 30 straight and bendable only

Suitable for use with top fix

NOTSuitable for use with topfix

Remove part of the inner plastic section to create space to insert the joiner

Ensure magnet is at the front of the track so that the cover plate will locate correctly

No finials / end caps

3

85mm

60mm

60mm

30mm

30mm

30mm

30mm

85mm

25mm

100mm

100mm

Ice finial

Square Barrel finial

Collar finial

Cap finial

Torus finial

Ball finial

50mm

S Y S T E M 1 6 C E I L I N G

Page 4: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

B E N D I N G S Y S T E M 3 0

Bend B

Trim here

Trim here

Bend B

Bend CBend C

Bend A Bend A

Window centre

Joiner

Former with spring back gives a track bend radius of 150mm (we can supply this former)

Bend track until kerfs touch. Do not bend any further

All tracks over 2.4m long are supplied in 2 pieces. The track should be joined in the middle of the centre window.

It’s easy to achieve:

FORWARD BENDS REVERSE BENDS CONTINUOUS BENDS

Easy to bend on site at point of installation. No more measuring up and hoping. No transporting awkward and delicate bent tracks

4

Radius 150

Radius 150

Trim off excess track at the track ends4

Bracket spacing - see front page5

Bend from the centre working outwards. Bend A, then B, then C, one side then A-C on the other side

3

B E N D I N G TO F I T A B AY

Identify front and back of track

Insert joiner, pushing the plastic filler down the track and tighten screws2

1

Front

Back

Diagram shows track joiner attaching two track lengths at the window centre

Track radius

150mm

Form

er ra

dius

100mm

Page 5: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

Bend towards the straight end NOT LIKE THIS

B E N D I N G S YS T E M 3 0

This method causes internal stress in the track which can cause the gliders to jam

DO NOT try to bend towards another bendOpen end

Open end

Former

Former

Bend track until kerfs touch. Do not bend any further

J O I N I N G A L L T R A C K S

Trim ends and cover with end caps/finials

Uncut factory ends

Uncut factory ends Uncut factory ends

With careful installation gliders will smoothly pass over the track joins. There is no limit to maximum track length

Join together factory cut ends and trim off the excess at track ends only

Place a support bracket as close as possible to the join

Ensure the joins are butted together tightly before tightening lock screws

5

Trim off excess track at the track ends

Bracket spacing - see front page

1

2

3

Page 6: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

S I N G L E C O R D , S I N G L E C U R TA I N

T R A C K C O R D I N G I N S T R U C T I O N S

For a single curtain you will need in addition to hand-drawn componants:

– 1 x down pulley– 1 x return pulley– 1 x cord tensioner– 1 x overlap arm– cord (2 x track length and 2 x cord drop)

Tensioner

Cap end or any finialNote: Child safety regulations state:

Cord loop should be installed at least 1.5m from the floor

Down pulleyReturn pulley

Min 1.5m

Cord drop

D U A L C O R D , PA I R O F C U R TA I N S

Tensioner Tensioner

For a dual controlled pair of curtains, you will need:

– 2 x down pulleys– 2 x return pulley– 2 x cord tensioner– 1 x overlap arm– 1 x underlap arm– cord (2 x track length and 4 x cord drop)

Cord drop

Min 1.5m

100

Under lap Overlap

100

Knotted endsKnotted ends

Underlap arm Overlap arm

S I N G L E C O R D , PA I R O F C U R TA I N S

Tensioner

For a pair of curtains controlled by a single cord you will need:

– 1 x down pulley– 1 x return pulley– 1 x cord tensioner– 1 x overlap arm– 1 x underlap arm– cord (2 x track length and 2 x cord drop)

Underlap armOverlap arm

Min 1.5m

Cord drop

Knotted ends

6

Knotted ends

O V E R L A P A N D U N D E R L A P D I M E N S I O N S

Page 7: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

80mm

T W I S T S TO P E N D S

S U R F 8 0

C A M E R O N F U L L E R ‘ S U R F ’ G L I D E R S

to ensure curtains stay stacked back

Lead glider with magnet

Adjustable glider stop

Use adjustable 75 -105 wall brackets to allow curtains to stack back correctly with SURF 80

Drawrod carrier

10mm

C U R TA I N H E A D I N G S We recommend curtain headings should be underslung for all three tracks to ensure the best operation of the curtains

D R A W R O D C A R R I E R

M A G N E T I C G L I D E R B R A K E

7

60mm

Drawrod

Standard wall brackets will allow curtains to stack back correctly with SURF 60

S U R F 6 0

Page 8: SYSTEM 16 CEILING · 2018-07-10 · SYSTEM 16 CEILING SYSTEM 30 STRAIGHT SYSTEM 30 BENDABLE Fit track directly to ceiling or top board, using pre-drilled holes See page 8 for bracket

B R A C K E T S A N D F I T T I N G S

FA C E F I X B R A C K E T S F O R S YS T E M 3 0

D I R E C T C E I L I N G F I X F O R A L L T R A C K S

LO N G C E I L I N G S TA N D O F F

Standard bracket

All dimensions are in mm

Adjustable 80 -680mm

Heavy duty adjustable 110 -150 bracket

57 110 -150

41 50 50

Heavy duty adjustable 75 -110 bracket

Front Back

For System 30, NOT System 16

5050

75 -110

Double track bracket

30

55

140

Des

igne

d by

ww

w.a

liasd

esig

n.co

.uk

8

57

30

5757

57

Cover

CoverCover