Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor...

29
Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 (ppm) (ppm) Ambient + 100 0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1 Ambient + 100 0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 63 ND ND ND ND ND ND ND ND ND ND ND 221 ND ND ND ND ND ND ND ND ND ND ND B Notes: 1 2 3 4 -- * ND = NS = Analytical Result 4 S M Detection Limit 3 PCB Naphthalene Lead Mercury Nickel Copper Water Quality Standard 3 Mercury Parameter Total Suspended Solids Benzo(a)pyrene Unit (ppb) (ppb) Sample ID 030118-SIDI-F-U 030118-SIDI-F-D Nickel Copper Lead Zinc Zinc PCB Naphthalene Benzo(a)pyrene Total Suspended Solids Upcurrent (Ambient) Downcurrent Distance to Source Approx. 500 - 1000 ft 1 500 ft 2 Sample Time 07:52 07:41 Survey Date 03/01/2018 Survey Type V - Vessel Based Construction Activity SIDI - Silt Displacement Comments Periodic tug movements of excavator barge during sample collection. Tide Flood Source Location B189 Sample Location NS NS NS NS S = Near Surface, M = Mid-Depth, B = Near Bottom Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible Samples collected at the edge of the 500 ft mixing zone Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14 No detection limit or water quality standard None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages Not Detected Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14. Reported value exceeds the Water Quality Standard as stated in Condition 61 of NYSDEC Permit Facility ID 3-9903-00043/00012-14

Transcript of Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor...

Page 1: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

63 ND ND ND ND ND ND ND ND ND ND ND 221 ND ND ND ND ND ND ND ND ND ND ND

B

Notes: 1

2

3

4

--

*

ND =

NS =

An

aly

tic

al R

es

ult

4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 030118-SIDI-F-U 030118-SIDI-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Upcurrent (Ambient) Downcurrent

Distance to

SourceApprox. 500 - 1000 ft

1500 ft

2

Sample Time 07:52 07:41

Survey Date 03/01/2018

Survey Type V - Vessel Based

Construction Activity SIDI - Silt Displacement Comments Periodic tug movements of excavator barge during sample collection.

Tide Flood

Source Location B189

Sample

Location

NS

NSNS

NS

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Reported value exceeds the Water Quality Standard as stated in Condition 61 of NYSDEC Permit Facility ID 3-9903-00043/00012-14

Page 2: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

58.7 ND ND ND ND ND ND ND ND ND ND ND 211 ND ND ND ND ND ND ND ND ND ND ND

B

Notes: 1

2

3

4

--

*

ND =

NS =

An

aly

tic

al R

es

ult

4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 030118-JETT-F-U 030118-JETT-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Upcurrent (Ambient) Downcurrent

Distance to

SourceApprox. 500 - 1000 ft

1500 ft

2

Sample Time 09:35 09:27

Survey Date 03/01/2018

Survey Type V - Vessel Based

Construction Activity JETT - Jetting CommentsOccuring concurently with Sediment Displacement at same location. Periodic tug movements of

excavator barge during sampling.

Tide Flood

Source Location B189

Sample

Location

NS

NS

NS

NS

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Reported value exceeds the Water Quality Standard as stated in Condition 61 of NYSDEC Permit Facility ID 3-9903-00043/00012-14

Page 3: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

298 ND ND ND ND ND ND ND ND ND ND ND 55 ND ND ND ND ND ND ND ND ND ND ND

B 64.5 ND ND ND ND ND ND ND ND ND ND ND 77 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

Sample Time 11:07 10:45

Survey Date 03/05/2018

Survey Type V - Vessel Based

Construction Activity JETT - Jetting Comments

Tide Flood

Source Location B187

Sample

LocationUpcurrent (Ambient) Downcurrent

Distance to

SourceApprox. 500 - 1000 ft

1500 ft

2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 030518-JETT-F-U 030518-JETT-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

An

aly

tic

al R

es

ult

4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Page 4: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

39.5 ND ND ND ND ND ND ND ND ND ND ND 45.5 ND ND ND ND ND ND ND ND ND ND ND

B 50 ND ND ND ND ND ND ND ND ND ND ND 44 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS = Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Tide Ebb

Source Location B187

Sample

LocationUpcurrent (Ambient) Downcurrent

Distance to

SourceApprox. 500 - 1000 ft

1800 ft

2

Sample ID 030618-JETT-E-U 030618-JETT-E-D

Zin

c

Survey Date 03/06/2018

Survey Type V - Vessel Based

Construction Activity JETT - Jetting Comments Due to access restrictions sample collected beyond edge of 500ft mixing zone.

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Sample Time 15:02 14:45

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected beyond the edge of the 500 ft mixing zone due to access

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M NS NS

Page 5: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

37 ND ND ND ND ND ND ND ND ND ND ND 36 ND ND ND ND ND ND ND ND ND ND ND

B 40.5 ND ND ND ND ND ND ND ND ND ND ND 44.5 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

Sample Time 12:07 11:53

Survey Date 03/08/2018

Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B128

Sample

LocationUpcurrent (Ambient) Downcurrent

Distance to

SourceApprox. 500 - 1000 ft

1500 ft

2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 030818-TIDO-F-U 030818-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

An

aly

tic

al R

es

ult

4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Page 6: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

39.7 ND ND ND ND ND ND ND ND ND ND ND 32 ND ND ND ND ND ND ND ND ND ND ND

B 36.5 ND ND ND ND ND ND ND ND ND ND ND 35 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS = Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Tide Ebb

Source Location B113

Sample

LocationUpcurrent (Ambient) Downcurrent

Distance to

SourceApprox. 500 - 1000 ft

1300 ft

2

Sample ID 030918-TIDO-E-U 030918-TIDO-E-D

Zin

c

Survey Date 03/09/2018

Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Sample Time 10:06 10:22

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within 500ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M NSNS

Page 7: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

32 ND ND ND ND ND ND ND ND ND ND ND 29.3 ND ND ND ND ND ND ND ND ND ND ND

B 43 ND ND ND ND ND ND ND ND ND ND ND 29 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within 500ft mixing zone.

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

An

aly

tic

al R

es

ult

4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 031218-TIDO-F-U 031218-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Sample

LocationUpcurrent (Ambient) Downcurrent

Distance to

SourceApprox. 500 - 1000 ft

1150 ft

2

Sample Time 09:25 09:11

Survey Date 03/12/2018

Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B112

Page 8: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

20.7 ND ND ND ND ND ND ND ND ND ND ND 24.7 ND ND ND ND ND ND ND ND ND ND ND

22 ND ND ND ND ND ND ND ND ND ND ND 41.3 ND ND ND ND ND ND ND ND ND ND ND

B 56.5 ND ND ND ND ND ND ND ND ND ND ND 76.7 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Tide Ebb

Source Location B176

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 031418-JETT-E-U 031418-JETT-E-D

Zin

c

Survey Date 03/14/2018Survey Type V - Vessel Based

Construction Activity JETT - Jetting Comments

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Sample Time 15:23 14:56

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M

Page 9: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

21 ND ND ND ND ND ND ND ND ND ND ND 28 ND ND ND ND ND ND ND ND ND ND ND

B 28 ND ND ND ND ND ND ND ND ND ND ND 23.5 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

An

aly

tic

al R

es

ult4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 031418-TIDO-F-U 031418-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 170 ft2

Sample Time 09:57 09:35

Survey Date 03/14/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B96

Page 10: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

24.3 ND ND ND ND ND ND ND ND ND ND ND 24 ND ND ND ND ND ND ND ND ND ND ND

55.7 ND ND ND ND ND ND ND ND ND ND ND 40.5 ND ND ND ND ND ND ND ND ND ND ND

B 104 ND ND ND ND ND ND ND ND ND ND ND 181 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected as close to the edge of the 500 ft mixing zone as was safe and practical

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

An

aly

tic

al R

es

ult4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 031518-JETT-F-U 031518-JETT-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 750 ft2

Sample Time 09:23 08:57

Survey Date 03/15/2018Survey Type V - Vessel Based

Construction Activity JETT - Jetting Comments

Tide Flood

Source Location B176

Sample Location

Page 11: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

31 ND ND ND ND ND ND ND ND ND ND ND 38.7 ND ND ND ND ND ND ND ND ND ND ND

B 32 ND ND ND ND ND ND ND ND ND ND ND 30.3 ND ND ND ND ND ND ND ND ND 4.8 ND

Notes: 1

2

3

4

--

*

ND =

NS =

Sample Time 10:05 09:52

Survey Date 03/15/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B94

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 175 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 031518-TIDO-F-U 031518-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

An

aly

tic

al R

es

ult4

S

M

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

NS NS

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Page 12: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

24 ND ND ND ND ND ND ND ND ND ND ND 25.5 ND ND ND ND ND ND ND ND ND ND ND

B 26.3 ND ND ND ND ND ND ND ND ND ND ND 28.3 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

An

aly

tic

al R

es

ult4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 031618-TIDO-F-U 031618-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 120 ft2

Sample Time 10:54 10:43

Survey Date 03/16/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B92

Sample Location

Page 13: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

57 ND ND ND ND ND ND ND ND ND ND ND 47.3 ND ND ND ND ND ND ND ND ND ND ND

92 ND ND ND ND ND ND ND ND ND ND ND 64 ND ND ND ND ND ND ND ND ND ND ND

B 134 ND ND ND ND ND ND ND ND ND ND ND 95 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Sample Time 10:32 09:54

Survey Date 03/17/2018Survey Type V - Vessel Based

Construction Activity JETT - Jetting Comments

Tide Flood

Source Location B176

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 031718-JETT-F-U 031718-JETT-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

An

aly

tic

al R

es

ult4

S

M

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Page 14: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

66 ND ND ND ND ND ND ND ND ND ND ND 68.5 ND ND ND ND ND ND ND ND ND ND ND

B 70 ND ND ND ND ND ND ND ND ND ND ND 73.5 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

An

aly

tic

al R

es

ult4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 031918-TIDO-F-U 031918-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 250 ft2

Sample Time 10:39 10:19

Survey Date 03/19/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B91

Sample Location

Page 15: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

33.2 ND ND ND ND ND ND ND ND ND ND ND 45 ND ND ND ND ND ND ND ND ND ND ND

B

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

NS NS

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

An

aly

tic

al R

es

ult4

S

M

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032018-JETT-F-U 032018-JETT-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample Time 12:18 12:05

Survey Date 03/20/2018Survey Type V - Vessel Based

Construction Activity JETT - Jetting Comments

Tide Flood

Source Location B189

Page 16: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

60.5 ND ND ND ND ND ND ND ND ND ND ND 73.5 ND ND ND ND ND ND ND ND ND ND ND

B 64.5 ND ND ND ND ND ND ND ND ND ND ND 82 ND ND ND ND ND ND ND ND ND 7.5 ND

Notes: 1

2

3

4

--

*

ND =

NS =

Sample Time 09:27 09:11

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Survey Date 03/20/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B89

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 100 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032018-TIDO-F-U 032018-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

An

aly

tic

al R

es

ult4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

NS NS

Page 17: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

50 ND ND ND ND ND ND ND ND ND ND ND 78.5 ND ND ND ND ND ND ND ND ND ND ND

B

Notes: 1

2

3

4

--

*

ND =

NS =

NS NS

NS NS

Sample Time 12:49 12:35

Survey Date 03/22/2018Survey Type V - Vessel Based

Construction Activity JETB - Jetting by Ballard Comments

Tide Flood

Source Location B189

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032218-JETB-F-U 032218-JETB-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

An

aly

tic

al R

es

ult4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Page 18: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

88.5 ND ND ND ND ND ND ND ND ND ND ND 143 ND ND ND ND ND ND ND ND ND ND ND

B 95 ND ND ND ND ND ND ND ND ND ND ND 109 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

5

--

*

ND =

NS =

Sample Time 13:32 13:14

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Survey Date 03/22/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Tide Flood

Source Location B86

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 120 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032218-TIDO-F-U 032218-TIDO-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

An

aly

tic

al R

es

ult4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

NS NS

Value is considerably lower than ambient values from samples collected at adjacent locations on this date and is likely not representative of ambient conditions

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Reported value exceeds the Water Quality Standard as stated in Condition 61 of NYSDEC Permit Facility ID 3-9903-00043/00012-14

Page 19: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

26 ND ND ND ND ND ND ND ND ND ND ND 25 ND ND ND ND ND ND ND ND ND ND ND

45.7 ND ND ND ND ND ND ND ND ND ND ND 30 ND ND ND ND ND ND ND ND ND ND ND

B 69.5 ND ND ND ND ND ND ND ND ND ND ND 54.5 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M

Sample Time 09:21 08:49

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Survey Date 03/24/2018Survey Type V - Vessel Based

Construction Activity JETT - Jetting Comments

Tide Ebb

Source Location B175

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 032418-JETT-E-U 032418-JETT-E-D

Zin

c

Page 20: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

27.5 ND ND ND ND ND ND ND ND ND ND ND 29 ND ND ND ND ND ND ND ND ND ND ND

B 54 ND ND ND ND ND ND ND ND ND ND ND 40 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M NS NS

Sample Time 14:28 14:09

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the outer edge of the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Survey Date 03/26/2018Survey Type V - Vessel Based

Construction Activity DBRI - Debris Removal Comments

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Tide Ebb

Source Location B171

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 032618-DBRI-E-U 032618-DBRI-E-D

Zin

c

Water Quality

Standard3

2 Samples collected at the edge of the 500 ft mixing zone

Page 21: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

34 ND ND ND ND ND ND ND ND ND ND ND 33.3 ND ND ND ND ND ND ND ND ND ND ND

B 35 ND ND ND ND ND ND ND ND ND ND ND 50 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS = Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Tide Ebb

Source Location B84

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 032618-TIDO-E-U 032618-TIDO-E-D

Zin

c

Survey Date 03/26/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Sample Time 10:39 10:22

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected within the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M NS NS

Page 22: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

22 ND ND ND ND ND ND ND ND ND ND ND 17 ND ND ND ND ND ND ND ND ND ND ND

29.7 ND ND ND ND ND ND ND ND ND ND ND 50 ND ND ND ND ND ND ND ND ND ND ND

B 74 ND ND ND ND ND ND ND ND ND ND ND 60 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Sample Time 09:29 08:59

Survey Date 03/27/2018Survey Type V - Vessel Based

Construction Activity DBRI - Debris Removal Comments

Tide Flood

Source Location B171

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032718-DBRI-F-U 032718-DBRI-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

An

aly

tic

al R

es

ult4

S

M

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at outer edge of 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

2 Samples collected at the edge of the 500 ft mixing zone

Page 23: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

24 ND ND ND ND ND ND ND ND ND ND ND 22.3 ND ND ND ND ND ND ND ND ND ND ND

37.7 ND ND ND ND ND ND ND ND ND ND ND 40 ND ND ND ND ND ND ND ND ND ND ND

B 53 ND ND ND ND ND ND ND ND ND ND ND 70 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Tide Ebb

Source Location B176

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 032718-SIDI-E-U 032718-SIDI-E-D

Zin

c

Survey Date 03/27/2018Survey Type V - Vessel Based

Construction Activity SIDI - Silt Displacement Comments

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Sample Time 11:27 10:56

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M

Page 24: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

26.3 ND ND ND ND ND ND ND ND ND ND ND 25.3 ND ND ND ND ND ND ND ND ND ND ND

B 29.7 ND ND ND ND ND ND ND ND ND ND ND 24.3 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS =

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M NS NS

Sample Time 10:34 10:15

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at outer edge of the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Survey Date 03/27/2018Survey Type V - Vessel Based

Construction ActivityTIDO - Timber Dolphin

RemovalComments

Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Tide Ebb

Source Location B127

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 032718-TIDO-E-U 032718-TIDO-E-D

Zin

c

Water Quality

Standard3

2 Samples collected at the edge of the 500 ft mixing zone

Page 25: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

18.3 ND ND ND ND ND ND ND ND ND ND ND 29.7 ND ND ND ND ND ND ND ND ND ND ND

38.3 ND ND ND ND ND ND ND ND ND ND ND 38.7 ND ND ND ND ND ND ND ND ND ND ND

B 59.3 ND ND ND ND ND ND ND ND ND ND ND 60.4 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Sample Time 09:42 09:03

Survey Date 03/28/2018Survey Type V - Vessel Based

Construction Activity DBRI - Debris Removal Comments

Tide Flood

Source Location B171

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032818-DBRI-F-U 032818-DBRI-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

An

aly

tic

al R

es

ult4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Page 26: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

21 ND ND ND ND ND ND ND ND ND ND ND 24.3 ND ND ND ND ND ND ND ND ND ND ND

51 ND ND ND ND ND ND ND ND ND ND ND 32.3 ND ND ND ND ND ND ND ND ND ND ND

B 55.3 ND ND ND ND ND ND ND ND ND ND ND 60.3 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Sample Time 10:56 10:24

Survey Date 03/28/2018Survey Type V - Vessel Based

Construction Activity JETB - Jetting Comments

Tide Flood

Source Location B176

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032818-JETB-F-U 032818-JETB-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

An

aly

tic

al R

es

ult4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Page 27: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

22.7 ND ND ND ND ND ND ND ND ND ND ND 22.7 ND ND ND ND ND ND ND ND ND ND ND

B 40.7 ND ND ND ND ND ND ND ND ND ND ND 51 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

NS = Not Sampled due to water depth, pursuant to 8/6/13 modification to Condition 60 of NYSDEC Permit Facility ID 3-9903-00043/00012-14.

Tide Ebb

Source Location B168

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 032818-SIDI-E-U 032818-SIDI-E-D

Zin

c

Survey Date 03/28/2018Survey Type V - Vessel Based

Construction Activity SIDI - Silt Displacement Comments

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Sample Time 12:02 11:45

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M NS NS

Page 28: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

22.3 ND ND ND ND ND ND ND ND ND ND ND 21.3 ND ND ND ND ND ND ND ND ND ND ND

54.5 ND ND ND ND ND ND ND ND ND ND ND 28.7 ND ND ND ND ND ND ND ND ND ND ND

B 96.7 ND ND ND ND ND ND ND ND ND ND ND 94 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Sample Time 09:10 08:45

Survey Date 03/29/2018Survey Type V - Vessel Based

Construction Activity DBRI - Debris Removal Comments

Tide Flood

Source Location B171

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Sample ID 032918-DBRI-F-U 032918-DBRI-F-D

Nic

ke

l

Co

pp

er

Le

ad

Zin

c

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal S

us

pe

nd

ed

S

olid

s

Detection Limit3

PCB

Na

ph

tha

len

e

Le

ad

Me

rcu

ry

Nic

ke

l

Co

pp

er

Water Quality

Standard3

Me

rcu

ry

Pa

ram

ete

r

To

tal S

us

pe

nd

ed

S

olid

s

An

aly

tic

al R

es

ult4

S

M

S = Near Surface, M = Mid-Depth, B = Near Bottom

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

Page 29: Survey Date 03/01/2018 Survey Type Construction Activity ... · 8/3/2019  · Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

Aro

clo

r 1

24

2

Aro

clo

r 1

24

8

Aro

clo

r 1

25

4

Aro

clo

r 1

26

0

(ppm) (ppm)

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

Am

bie

nt

+

10

0

0.07 3.7 2.6 1.8 5.6 0.2 0.2 0.2 0.2 -- 0.1

* 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006 * 0.0007 8.2 5.6 8.0 66 -- -- -- -- 16 0.0006

37.3 ND ND ND ND ND ND ND ND ND ND ND 51.3 ND ND ND ND ND ND ND ND ND ND ND

B 49.7 ND ND ND ND ND ND ND ND ND ND ND 38.3 ND ND ND ND ND ND ND ND ND ND ND

Notes: 1

2

3

4

--

*

ND =

Tide Ebb

Source Location B168

Sample Location

Upcurrent (Ambient) Downcurrent

Distance to Source

Approx. 500 - 1000 ft1 500 ft2

Sample ID 032918-SIDI-E-U 032918-SIDI-E-D

Zin

c

Survey Date 03/29/2018Survey Type V - Vessel Based

Construction Activity SIDI - Silt Displacement Comments

Water Quality

Standard3

Nic

ke

l

Co

pp

er

Zin

c

PCB

Na

ph

tha

len

e

Be

nzo

(a)p

yre

ne

To

tal

Su

sp

en

de

d

So

lid

s

Le

ad

Pa

ram

ete

r

To

tal

Su

sp

en

de

d

So

lid

s

Me

rcu

ry

Nic

ke

l

Co

pp

er

Me

rcu

ry

Le

ad

Sample Time 14:04 13:45

S = Near Surface, M = Mid-Depth, B = Near Bottom

Based on New York State Department of Environmental Conservation (NYSDEC) Permit Facility ID 3-9903-00043/00012-14

Samples collected at a location up current of the source where the water quality effects of the project are no longer discernible

Samples collected at the edge of the 500 ft mixing zone

Be

nzo

(a)p

yre

ne

Unit (ppb) (ppb)

Detection

Limit3

PCB

Na

ph

tha

len

e

No detection limit or water quality standard

None from sewage, industrial waste or other wastes that will cause deposition or impair the waters for their best usages

Not Detected

An

aly

tic

al

Re

su

lt4

S

M NS NS