Surface Power – PDRJohn Dankanich (2-13-01)
Dispersion Fueled 100 kWe Reactor
![Page 2: Surface Power – PDR John Dankanich (2-13-01)](https://reader036.fdocuments.in/reader036/viewer/2022082611/56812c61550346895d90f323/html5/thumbnails/2.jpg)
System Dimensions
Assumed 500 M from Routine Activity
![Page 3: Surface Power – PDR John Dankanich (2-13-01)](https://reader036.fdocuments.in/reader036/viewer/2022082611/56812c61550346895d90f323/html5/thumbnails/3.jpg)
Mass BreakdownSubsystem Weight Breakdown
0
200
400
600
800
1000
1200
Heat Pipes Pow er Control Radiator Reactor Shield Structure TE Converter ThermalInsulation
Wire
We
igh
t (K
g)
Total Mass is Approximately 3,000 Kg.
![Page 4: Surface Power – PDR John Dankanich (2-13-01)](https://reader036.fdocuments.in/reader036/viewer/2022082611/56812c61550346895d90f323/html5/thumbnails/4.jpg)
Cost Analysis
Cost of Complete System: $750 Million
• Development
• Production
• Testing
Each additional unit $250 Million
• High Cost due to testing
![Page 5: Surface Power – PDR John Dankanich (2-13-01)](https://reader036.fdocuments.in/reader036/viewer/2022082611/56812c61550346895d90f323/html5/thumbnails/5.jpg)
Risk Assessment
Radiation: Over 500m Distance for routine crew activity
Radiation below acceptable occupational dosage
Failure: Single Failure Modes are Difficult to Eliminate
History - 3 Nuclear Incidents in 19 US missions
Transit-5BN-3, Nimbus, Apollo 13
Snap-10A Reactor Failure
Terrestrial Plant 1/17000 Reactor Years
![Page 6: Surface Power – PDR John Dankanich (2-13-01)](https://reader036.fdocuments.in/reader036/viewer/2022082611/56812c61550346895d90f323/html5/thumbnails/6.jpg)
Comparisons
Existing Space Power
• Heavier, Lower Shielding
Terrestrial
• Lighter, Smaller, Passive
DRM
• Lighter, Lower Power
Dr. Zubrin
• Comparable Mass, Comparable Power
![Page 7: Surface Power – PDR John Dankanich (2-13-01)](https://reader036.fdocuments.in/reader036/viewer/2022082611/56812c61550346895d90f323/html5/thumbnails/7.jpg)
Bottom Line
• Cost of $750 Million ($250 Million per additional unit)
• Reliability of 0.95 (0.98 after prototype)
• Power Output 100 kWe (115 capable)
• Lifetime of 5 years (7 max)
• Mass of 3 Tonnes
• Footprint of 13 m2