Schlumberger REDA Production Systems  XPERT ESP

SURFACE

EQUIPMENT

ESP Component

Page 2: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 2/31

SURFACE COMPONENT

- Transformer 

- Switch Board

- Junction box

- Well Head or tubing head

XPERT ESP

Page 3: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 3/31

SURFACE EQUIPMENT 

Shown here is the surface related equipment required for 

most down-hole electrical submergible pump systems.

Transformer Motor speedcontroller

Junction Box Well Head

XPERT ESP

Page 4: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 4/31

SURFACE EQUIPMENT 

Transformer 

• Provides required voltage for down hole motor 

• Works by transforming the voltage through induction magnetic field

• In general, 3 types of transformer :

- Single phase transformer 

- Three phases transformer 

- Auto transformer  

• 4 Main construction parts :

- Core (lamination body)- Primary winding

- Secondary winding

- Enclosure 

XPERT ESP

Page 5: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 5/31

SURFACE EQUIPMENT 

Transformer 

The transformer sends the correct

voltage to the Switchboard for designed

surface voltage for the proper motor 

operation.

This is based on power rating in KVA.

Transformers can be either single phase

or three phase.

XPERT ESP

Page 6: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 6/31

SURFACE EQUIPMENT 

Transformer Normally when using single phase transformers

for three phase power, three individual

transformers are connected together, in various

configurations.

 A single phase transformer 

generally appears similar to

the figure shown.

XPERT

ESP

Page 7: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 7/31

SURFACE EQUIPMENT 

CORE

WINDING

XPERT

ESP

Page 8: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 8/31

SURFACE EQUIPMENT 

V1 = T1 -------> 600 = 10 ----->

V2  T2 V2 2

600 VOLTS (10 TURNS)120 VOLTS (2 TURNS)

120 VOLTS

V2V2

V2  = 600 X 2 =

10

XPERT

ESP

Page 9: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 9/31

SURFACE EQUIPMENT 

DETERMINE TRANSFORMER’S KVA 

Sample : Motor 180 HP/ 1000 V/ 103 Amp

PSD 3000 Ft, SBHT = 200°F

Cable AWG -1, length 3100 Ft.

Voltage drop (from chart) = 24 Volts/ 1000 Ft

Total Volt drop = 24 x {(3100+100) / 1000)} =76.8 Volts

Required surface voltage = 1000 + 76.8 = 1076.8 VoltsKVA = (Surface Volt x Amps x 1.732) / 1000

= (1076.8 x 103 x 1.732) / 1000

= 192.1 KVA ---------->  Choose 200 KVA (Minimum)

103

24 AWG #1

XPERT

ESP

Page 10: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 10/31

• TRANSFORMER 

- Variable input Voltage 7200 V - 13000 V

- High voltage required in the transmission to get lower 

 Amperage, in order to allow smaller size cable

- Input voltage decreased by a step down transformer to

meet required motor voltage

SURFACE EQUIPMENT XPERT

ESP

Page 11: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 11/31

• Switch Board - Control panel for electric motor 

- Equipped with motor controller 

• Monitors overload / under load problems 

• Can be set to auto restart in the case of intermittent well 

• Detects voltage unbalance 

- Equipped with Amp chart to record motor performance

SURFACE EQUIPMENT  XPERT

ESP

Page 12: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 12/31

SURFACE EQUIPMENT  XPERT

ESP

Reda Switchboard

• Ratings

• DFH2 600 Volt

• MFH 1000 Volt• MDFH 1500 Volt

•  AB 1512 3900 Volt*

* Available to 5000V by changing P.T.

Page 13: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 13/31

SURFACE EQUIPMENT  XPERT

ESP

Switchboard

• Ratings:

 – Maximum Voltage

 – Maximum Amp Load – Maximum KVA

Page 14: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 14/31

SURFACE EQUIPMENT  XPERT

ESPSwitchboard

Selecting a Switchboard

• Select a Switchboard with the appropriate

Volt, Amp and KVA rating

• Select a motor controller type and feature

• Select a wiring harness for the motor controller.

Page 15: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 15/31

• Switch Boards 

FOUR MAIN COMPONENTS

• MAIN BREAKER 

To connect high voltage from the transformer to the down hole motor 

• POTENTIAL TRANSFORMER (PT) 

To reduce the high voltage to 120 Volts, for use by the control systems in the

switch board - and to hold magnetic field in the Vacuum contactor 

• CURRENT TRANSFORMER (CT)

Reduce high amperage in the circuit to 5 amps for ease of measurements

• VACUUM CONTACTOR 

Function is to absorb spark that possibly occur in the contactor system

during start and stop switching operations.

SURFACE EQUIPMENT XPERT

ESP

Page 16: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 16/31

SURFACE EQUIPMENT 

SWITCH BOARD

• 3 MAIN FUNCTIONS 

- Motor starter unit

- Protective equipment for overload and under load problems

- Recording Instruments

• SWITCH BOARD CONTENT 

- Manual Switch breaker 

- Motor controller 

- Gas locking protector 

- Restart relays for intermittent well

- Ampere chart mechanic

XPERT

ESP

Page 17: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 17/31

SURFACE EQUIPMENT 

Potential Transformers

Installed in the switchboard

Used to step-down the high voltage to a control voltage of 120 volts

(no load).

The 120 volts is used to run all the control circuits in the Switchboard.

Motor controllers will monitor the control voltage; and using the P.T.

ratio calculate the line voltage in the switchboard.

XPERT

ESP

Page 18: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 18/31

SURFACE EQUIPMENT  XPERT

ESPPotential Transformers

• Transformer Rating 1430/126

Calculate the Ratio 1430 = 11.35

• Measured secondary Voltage = 119V

119V X 11.35 = 1350V on the primary

126

Page 19: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 19/31

SURFACE EQUIPMENT  XPERT

ESP

Current Transformers

 Another type of transformer which is used

in the motor controller is the “CurrentTransformer". (CT)

This type of transformer changes one

current to a different current.

Page 20: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 20/31

SURFACE EQUIPMENT  XPERT

ESPCurrent Transformers

 As an example, if 180A is flowing through the conductor, sothe TR is 200:5, the amperage on the secondary side of theCT will be:

Sec. Amps =

180

(200:5) = 4.5 A 180A

4.5 A

Sec. Amps =180

200x 5 = 4.5 A

or 

Page 21: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 21/31

SURFACE EQUIPMENT  XPERT

ESPCurrent Transformers

CT also transforms the motor amperage at the

primary side, to 5 amps (maximum) at secondary

side, in order to be able to record the current on

the amp chart.

However motor amps display are best at the

middle of the range between 0 – 5, to give space

for overload and under load problems recorded

Page 22: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 22/31

SURFACE EQUIPMENT  XPERT

ESP

Motor running amps

0

5 Amps

Current Transformers

Page 23: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 23/31

SURFACE EQUIPMENT  XPERT

ESPCurrent Transformers

 A conductor passes through the winding of the CT andenergizes the CT. Typically the CT ranges used in theSPS controllers have a ratio of 200:5, 300:5, 150:5,75:5 etc.

Primary side

Secondary side

Page 24: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 24/31

SURFACE EQUIPMENT  XPERT

ESPCurrent Transformers

Given example: Available single tap CT 300:5 ratio. Motor load: 85 Amps.

CT set up: 85 x 1.6 = 136. --- CT ratio 150 : 5

Working Amperage at amps chart control :

(85/150) x 5 = 2.8 A

 Available CT 300 : 5 (85/300) x 5 = 1.42 A.

Page 25: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 25/31

SURFACE EQUIPMENT  XPERT

ESP

Current Transformers

CT ratio 150 : 5 CT ratio 300 : 5

Solution : Make two turns of wire

Page 26: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 26/31

If one pass of the wire results is greater than 5A, the CT ratiomust be increased by going to a CT with a higher turns ratio.

Control Circuit amperage can also be increased by two by

looping the wire for two passes; or by three with three passes.

Current Transformers

SURFACE EQUIPMENT  XPERT

ESP

Page 27: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 27/31

SURFACE EQUIPMENT  XPERT

ESPCurrent Transformers

Sizing CT’s 

 Amps through S.B. X 1.6 = CT primary size

e.g. 59 A X1.6 = 94 Amps

100:5 CT = 20:1

59/20 = 2.95 Amps Secondary Current

Motor Controllers work best between 2.5 -3.5 Amps

Page 28: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 28/31

SURFACE EQUIPMENT 

JUNCTION BOX

FUNCTION:

• Ventilation for gas that possibly

comes up to surface through thecable

• Connection terminals, easier to

reverse motor rotation and to take

initial readings.

JUNCTION BOX

XPERT

ESP

XPERTSURFACE EQUIPMENT

Page 29: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 29/31

Wellhead

The Wellhead is the equipment

that is installed at the surface of 

the well bore.

It’s purpose is: to suspend thetubing string in the well, and to

monitor and control high

pressures conditions often

present within the well.

XPERT

ESP

SURFACE EQUIPMENT 

Page 30: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 30/31

FROM

JUNCTION

BOX

ATTACHABLE

CONNETOR

(ASSEMBLY)

PENETRATOR

SURFACE

POWER PLUG

STRAPPED

CABLE BAND

PICK UP TUBING

TUBING HANGER

PAU/ XPERT ESP/ IWS

PRODUCTION TUBING

WELL HEAD

CONNECTOR

ASSEMBLY

XPERT

ESPSURFACE EQUIPMENT 

O RING

IWS- XpertESP 2002

Page 31: Surface Component English

7/28/2019 Surface Component English

http://slidepdf.com/reader/full/surface-component-english 31/31

PAU/ XPERT ESP/ IWS

GLAND NUT

POWER CABLE

FROM JBOX

RUBBER SEAL METALSPLIT

RING

WELL HEAD

PACK OFF

ASSEMBLY

XPERT

ESPSURFACE EQUIPMENT 

O RING

IWS XpertESP 2002