Catalysts Ceramics Energy Carbon Pharma © 2013 Quantachrome Corporaon 1013 07160-EVO Rev A QUADRASORB e v o surface area & pore size analyzer e v o = evolution The ability to adapt to a changing environment over time. This imparts a higher survival rate compared to those species that do not evolve.

Transcript of Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size »...

Page 1: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

Catalysts

Ceramics

Energy

Carbon

Pharma

© 2013 Quantachrome Corporation 1013 07160-EVO Rev A

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™

surface area & pore size analyzer

evo = evolutionThe ability to adapt to a changing environment over time. This imparts a higher survival rate compared to those species that do not evolve.

Page 2: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™ New Improved Features & Benefits

» BET QuickMode™ - For industrial high throughput settings - Time savings up to 50%.

• By passes most initialization, extended evacuation, and transducer zeroing sequences.

• Samples can run synchronously.

» Dedicated Po transducer and manifold provides uninterrupted dosing of samples during measurements.

• Po can be continually measured.

• No need to stop measurement to update Po.

• No slow down in analysis to measure Po.

» Flexible Po Modes:

• Po can be estimated from ambient atmospheric pressure.

• Po can be entered as fixed value.

• Po can be analytically measured.

» New Hardware Features:

• Soft closing protective door with pneumatic hinges for operator safety.

• Integrated, insulated dewar covers incorporated in lift mechanism to extend the life and insulating the dewar content.

• Smooth belt drive dewar lift for precise control of Quantachrome’s novel small cold zone.

• New 1 torr, low pressure transducer for krypton and micropore measurements.

• Stainless steel gas paths including metal to metal seals for optimal vacuum performance.

» New Dose Wizard™ Flexibility:

• Can use a previously measured sample as a dosing template for reduced analysis time.

• Can be used with or without QuickMode™.

* For information on optimizing analysis speeds, see Technote #58-”Optimizing Gas Sorption Parameters to Minimize B.E.T. Surface Area Analysis Time”.

Benefits - Speed, Accuracy & Flexibility

Quantachrome’s QUADRASORB evoTM Surface Area and Pore Size Analyzer is designed to satisfy busy laboratory needs for high analytical throughput, without sacrificing precision, flexibility or cost-effectiveness. Up to four simultaneous and independent analysis ports remove the limitations of single dewar systems allowing samples to be started as soon as previous measurements are completed. A dedicated transducer has been provided for measurement of Po (adsorbate saturated vapor pressure), so that continually measuring Po does not slow down analysis capabilities. The new BET “QuickModeTM” provides high throughput industrial materials characterization labs the ability to process samples at dramatically improved speeds. This measure-ment flexibility has never before been available in such a compact and cost-effective package.

1Visit www.quantachrome.com for more detailed instrument specifications and download brochures.

Capable of running four (4) samples in as little as 25 minutes.*

Page 3: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

The Newest Evolution in Gas Sorption Analysis

2

With soft close hinges.

Up to four independent sample stations; each can accommodate a variety of cell sizes.

Gravity Rings- extends dewar life by form fitting closure (up to 30 hours).

Automated, independent dewar elevators.

Lower front panel opens to provide unrestricted access for dewar placement, maintenance and clean-up.

» Fully automated, multi-sample port analyzer. Available with four, three or two sample stations. » Each of the analysis ports includes separate and independent Dewar (coolant flask), 1000 torr pressure

sensor and Po (adsorbate saturated vapor pressure) cell. » Each of the analysis ports includes coolant level sensor to maintain a constant, small cold-zone for maximum sensitivity.

» Communication port for PC control via Windows®-based software

Proven Features:» Each analysis port can be independently programmed with different analyses and measurement conditions. New samples can be started on each port as prior measurements are completed with little delay to other samples already in progress.

» Choose from two measurement techniques:

• Patented NOVA® helium-free method and classical helium void-volume method.

» Multiple gas dosing methods to optimize analysis time and resolution:

• Standard™- intelligently adjusts dose size in response to sample demand.

• Vector Dosing- user selectable dose volumes from 0.25 to 10cc per point

• Delta (volume) Max™ - adds data points in regions of large uptake so critical pore filling is never missed.

• Dose Wizard™- can be used with or without QuickModeTM enabled. This allows the instrument to

dose more aggressively, saving significant analysis time.

» Low maintenance, vacuum-volumetric system with temperature monitored dosing manifold.

Krypton / Micropore Option for Low Surface Area and Micropore Measurements

» Includes low pressure (1 torr) sensor and turbo-molecular vacuum pump. Available with optional oil-free roughing pump. » Performs krypton gas sorption measurements for very low surface area determination, e.g. pharmaceutical actives, powdered metals, etc. on any or all sample stations.

» Capable of low pressure adsorption data (as low as 4 x 10-5 P/Po) necessary for more complete characterization of microporous materials, e.g. zeolites, activated carbons, molecular sieves.

Page 4: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

Physical Specifications

Height: 29.0 inches (73.6 cm)

Height Open: 44.0 inches (111.6 cm)

Width: 25.25 inches (63.7 cm)

Depth: 21.0 inches (53.3 cm)

Depth Open: 26.2 inches (66.5 cm)

Weight: 57.5 kg (127 lbs.)*

Electrical: 100 - 240 VAC, 50/60 Hz

Environmental: 10 - 38°C operating range at 90%

maximum relative humidity.

* Four (4) station standard model not Kr/MP model.

Specifications / Accessories

Analysis Specifications

Pressure Transducers:Six* 1000 torr transducers (one on each sample station, plus dosing manifold and Po manifold)plus one# 1 torr transducer (dosing manifold)

Transducer Accuracy: 1000 torr: 0.11% full scale1 torr: 0.15% reading

Pressure Resolution:0.016 torr (1000 torr range). 0.000016 torr (1 torr range).

Ultimate Vacuum: <1x10-2 torr achieved by dedicated two (2) stage rotary, direct drive pump

1x10-9 torr achieved by turbo- molecular vacuum pump in QUADRASORB evoTM - Kr/MP

Adsorbate:Nitrogen or any other non-corrosive gas with appropriate coolant

Surface Area Range:0.01m2/g to no known upper limit (nitrogen) 0.0005 m2/g to no known upper limit (krypton) Kr/MP model only

Minimum Pore Volume: (liquid): 2x10-6 cc/g (STP): 0.0001cc/g

Pore Size Range:3.5 - 4000Å / 0.35 - 400 nm

Minimum P/Po (N2):

1 x 10-3 QUADRASORB evoTM 4 x 10-5 QUADRASORB evoTM- Kr/MP

Coolant Level:Automatically maintained at a level around the sample cell to minimize cold zone volume.

* Full Quadrasorb evo™ model. 2- and 3-station versions have 4 and 5 respectively.

# Kr/MP version only.

Visit www.quantachrome.com for more detailed instrument specifications and download brochures.

3

Page 5: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

4

Accelerated Analysis Times for Busy Labs

Is the QUADRASORB evoTM “evolutionary” or “revolutionary” ? You decide! Technical improvements have

made it possible to conduct surface area analyse up to 50% faster than previously!

QuickModeTM

Designed to benefit customers in an industrial setting that require high throughput BET surface area measurements. This is ideal for customers doing initial screening of candidate materials as part of a material discovery group. Our QuickModeTM will provide scienti- fically accurate surface area data.

QuickModeTM Features: • Shorter initialization cycle.

• All samples start at one time, running synchronously.

• When a sample finishes it is not immediately evacuated, but waits for the remaining samples in a batch to complete their runs unimpeded.

• Available in both classical helium void volume, helium free Nova mode, and with all of Po modes.

Dose Wizard TM

This unique proprietary method can yield even more

time savings by using a previously measured isotherm

as a dosing template. This provides the information

of how much gas the sample is likely to adsorb at

relative pressures utilizing the information from a

previous analysis. In this mode, the unit does not have

to learn and adjust how much gas to add in order to

achieve a data point at each relative pressure. This

results in significant time savings. The Dose WizardTM

can be used with or without QuickModeTM enabled.

This allows the instrument to dose more aggressively,

saving significant analysis time.

Software & Firmware Improvements for Speed

A new proprietary dosing algorithm, implemented

in the QUADRASORB evoTM firmware increases speed

and accuracy for reaching target pressure in the

mesopore range. For repeat analysis a feature has been

added in the software to allow the option of entering

previous measurements of a cold and warm zone.

This significantly saves time as well. The dosing

software has optimized the calculation of the rate

of adsorption required in each dose. This reduces

the number of doses required, and also speeds up

analysis times.

Compelling Impacts on Speed & Analysis Time

All of the various improvements made can speed up

analysis times from 30% to as high as 50% faster than

the predecessor QuadrasorbTM SI. The geatest increas-

es will be when using the QuickModeTM for standard

BET analysis using the NOVA® mode.

Up to 50% Faster Analysis Time*

*Than QuadrasorbTM SI using mesopore analysis in

turbo mode.

Four Multi-Point BET -Measurements in 25 Minutes!*

*Multi-point BET analysis performed in QuickModeTM

using Nova® mode.

*For information on optimizing analysis speeds, see Technote #58- ”Optimizing Gas Sorption Parameters to Minimize B.E.T. Surface Area Analysis Time”.

Page 6: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

» Available in both standard versions for BET surface area and mesopore size analysis, or upgrade to the

low pressure model for low surface area analysis using krypton and micropore characterization.

» Available in 2, 3, or 4 independent analysis stations.

5

Standard-Configuration for BET Analysis

QUADRASORB EVO™ 4 STATION 4-station (non turbo)

QUADRASORB EVO™ 3 STATION 3-station (non turbo)

QUADRASORB EVO™ 2 STATION 2-station (non turbo)

CFR- for 21 CFR Part 11

QUADRASORB EVO™ CFR 4 STATION 4-station CFR (non turbo)

QUADRASORB EVO™ CFR 3 STATION 3-station CFR (non turbo)

QUADRASORB EVO™ CFR 2 STATION 2-station CFR (non turbo)

QUADRASORB EVO™ CFR 4 STATION Kr/MP 4-station CFR Kr/MP (turbo + 1torr)

QUADRASORB EVO™ CFR 3 STATION Kr/MP 3-station CFR Kr/MP (turbo + 1torr)

QUADRASORB EVO™ CFR 2 STATION Kr/ MP 2-station CFR Kr/MP (turbo + 1torr)

The Newest evolution in Modularity & Flexibility for Gas Sorption Analysis

Flexible upgrade paths to meet your labs future evolutions in surface area analysis:

Krypton / Micropore Low Pressure Analysis

QUADRASORB EVO™ 4 STATION Kr/MP 4-station Kr/MP (turbo + 1torr)

QUADRASORB EVO™ 3 STATION Kr/MP 3-station Kr/MP (turbo + 1torr)

QUADRASORB EVO™ 2 STATION Kr/MP 2-station Kr/MP (turbo + 1torr)

QUADRASORB evoTM may be upgraded in the field from standard versions to the low pressure

micropore option.

Page 7: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

6

Evolve and adapt to your lab’s changing analysis needs

Visit www.quantachrome.com for more detailed instrument specifications and download brochures.

Field Upgrades

QUADRASORB EVO™, 2 to 3 EVO™Upgrade kit: from 2 station (EVO™) model to 3 station model

QUADRASORB EVO™, 3 to 4 EVO™Upgrade kit: from 3 station (EVO™) model to 4 station model

QUADRASORB EVO™, 2 to 4 EVO™ Upgrade kit: from 2 station (EVO™) model to 4 station model

QUADRASORB EVO™, 2 to 3 EVO™ Kr/MPUpgrade kit: from 2 station (EVO™) Kr/MP model to 3 station Kr/MP model

QUADRASORB EVO™, 3 to 4 EVO™ Kr/MPUpgrade kit: from 3 station (EVO™) Kr/MP model to 4 station Kr/MP model

QUADRASORB EVO™, 2 to 4 EVO™ Kr/MPUpgrade kit: from 2 station (EVO™) Kr/MP model to 4 station Kr/MP model

QUADRASORB evoTM is field upgradeable from 2 to 3 to 4 stations to evolve with changes in your

labs throughput needs over time. The evoTM may be upgraded in the field from standard versions to

the low pressure micropore option.

Purchase for your lab’s needs of today, but have the confidence of being able to adapt to changes in the future. It is very typical that laboratories get busier over time when value of surface area analysis becomes more apparent and their sample volumes increase. However it is also typical that your current budgets are constrained, and you are attempting to meet your present needs in the most cost effective manner.

The QUADRASORB evoTM gives you the ability to purchase for today’s needs, but leave the door open to expand to provide for larger throughput, without having to buy an entirely new instrument. You can purchase a 2, or 3 station QUADRASORB evoTM and expand at any point in the future to 3, or four stations. These upgrades are done in the field, so you don’t lose valuable down time while your instrument is being upgraded.

The evoTM also gives you the flexibility to upgrade to the MP micropore platform to allow analysis of microporous materials or low surface area samples using Krypton. Your lab might not be doing these types of analysis today, but it is not uncommon for researchers in advanced materials to migrate into new materials over time. If your research focus changes, you have the assurance that Quantachrome provides you an effortless field upgrade path.

Page 8: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

7

Gas Sorption Overview

Figure 1: A section of one greatly enlarged particle of a solid.

Figure 2: The monolayer of adsorbed molecules; typically 15 - 20% saturation.

Figure 3 : The multilayer capillary condensa-tion stage approximately 70% saturation.

Figure 4: Total pore volume filling; approximately 100% saturation.

The Gas Sorption Process

Before performing gas sorption experiments, solid surfaces must be freed from contaminants such as water and oils. Sur-face cleaning (degassing) is most often carried out by placing a sample of the solid in a glass cell and heating it under vac-uum or flowing gas. Figure 1 illustrates how a solid particle containing cracks, orifices and pores of different sizes and shapes might look after pretreatment.

Once clean, the sample is brought to a constant temperature by means of an external bath. Then, small amounts of a gas (the adsorbate) are admitted in steps into the evacuated sample chamber. Gas molecules that stick to the surface of the solid (adsorbent) are said to be adsorbed and tend to form a thin layer that covers the entire adsorbent surface. Based on the well-known Brunauer, Emmett and Teller (B.E.T.) theory, one can estimate the number of molecules required to cover the adsorbent surface with a monolayer of adsorbed molecules, Nm (Figure 2). Multiplying Nm by the cross-sectional area of an adsorbate molecule yields the sample’s surface area.

Continued addition of gas molecules beyond monolayer formation leads to the gradual stacking of multiple layers (multi layers). The formation occurs in parallel to capillary condensation (Figure 3). The latter process is approximately described by the Kelvin equation, which relates equilibrium gas pressure to the size of capillaries capable of condensing gas within them.

As the equilibrium gas pressure approaches saturation, the pores largely completely fill with adsorbate (Figure 4). Knowing the density of the adsorbate, one can calculate the volume it occupies and, consequently, the total pore volume of the sample. If at this stage one reverses the adsorption process by withdrawing known amounts of gas from the system in steps, desorption isotherms are generated. The resulting hysteresis leads to isotherm shapes that can be mechanistically related to those expected from particular pore-shapes.

Older calculation methods such as the one by Barrett, Joyner and Halenda (B.J.H.) allow the computation of pore sizes from equilibrium gas pressures. One can therefore take experimental curves (isotherms) of adsorbed gas volumes versus relative pressures and convert them to cumulative or differential pore size distributions.

Modern pore size models are based on Non-local Density Functional Theory (DFT)- a statistical mechanics approach that allows one to describe the sorption of gas molecules in nanoporous materials at a molecular level. Hence, the application of such microscopic-methods produces the most accurate surface area and pore size results.

Visit www.quantachrome.com for more detailed instrument specifications and download brochures.

Page 9: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

8

evo = Intelligence With Enhanced Sensitivity

Small Cold Zone For Increased Sensitivity

Coolant level controlled here creates a small cold zone.

Coolant level controlled here creates a large cold zone.

other

The sensitivity of a manometric sorption analyzer depends on the internal volume of the measure-ment zone (free space) and how many adsorbate molecules remain unadsorbed. The goal always therefore is to minimize the amount of unadsorb- ed gas occupying the free space. For example, filler rods that occupy the stem portion of the sample cell are commonly employed. Additionally the bulbous portion of the sample cell can be selected to minimize the free space, consistent with the bulk volume of the sample and its adsorption capacity. Measurements at lower absolute pressures can also be very effective, and this is why krypton (whose saturation pressure at liquid nitrogen temperature is approximately 1/300th that of nitrogen at the same temperature) is often employed when measuring extremely low surface areas (less than one square meter total for example). The amount of unadsorbed gas is also a function of the temperature of the free space: the higher it is the fewer molecules it contains for a given pressure, and the lower it is the more molecules are present at the same pressure. In any manometric instrument part of the free space is “warm” (not in coolant), and part is “cold” (submerged in coolant). Therefore it is advantageous to minimize the volume of free space that is cold since every cm3 at liquid nitrogen temperature (77.4K) contains almost four times as many unadsorbed molecules as every cm3 does around room temperature (e.g. 298K). It is true that for any cell geometry more of it should be warm and less should be cold for maximum sensitivity.

Cabinet

Coolant

Dewar Support Arm.

30 hr Dewar

Drive Shaft

Sample Cell

Level Sensor

The transparent blue door encloses the physisorption station for additional safety and improved tempera-ture control.

As the coolant evaporates, the level sensor signals the dewar drive to compensate for the change in level, thereby maintaining a constant and small cold zone.

»

Proprietary Technology for Enhanced Sensitivity

Page 10: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

9

NLDFT-Methods

• N2 at 77K on carbon

(slit pore, equilibrium model)

• N2 at 77K on carbon

(cylindrical pore, equilibrium model)

• N2 at 77K on carbon

(slit & cylindrical pores, equilibrium model)

• Ar at 77K on carbon

(slit pore, equilibrium model)

• Ar at 87K on carbon

(slit pore, equilibrium model)

• Ar at 87K on carbon

(cylindrical pore, equilibrium model)

• CO2 at 273K on carbon

(slit pore, equilibrium model)

• N2 at 77K on silica

(cylindrical pore, equilibrium model)

• N2 at 77K on silica

(cylindrical pore, adsorption branch model)

• N2 at 77K on silica

(cylindrical and spherical pores, adsorption

branch model)

• Ar at 87K on zeolites/silica

(spherical/cylindrical pore equilibrium model)

• Ar at 87K on zeolites/silica

(spherical/cylindrical pore adsorption branch

model)

• Ar at 87K on zeolites/silica

(cylindrical pore, equilibrium model)

• Ar at 87K on zeolites/silica

(cylindrical pore, adsorption branch model)

GCMC-Methods

• CO2- carbon at 273K based on a slit-pore model

Fractal Dimension

• Neimark-Kiselev (NK), Frenkel-Halsey-Hill (FHH)

QSDFT

• QSDFT – N2 – carbon equilibrium transition

kernel at 77 K based on a slit-pore model

• QSDFT – Ar – carbon equilibrium transition

kernel at 87 K based on a slit-pore model

• QSDFT – N2 – carbon adsorption branch kernel

at 77 K based on a cylindrical pore model

• QSDFT – N2 – carbon adsorption branch kernel

at 77 K based on a cylindrical pore model

• QSDFT – N2 – carbon equilibrium transition

kernel at 77 K based on a slitpore model

• QSDFT, N2, carbon equilibrium transition kernel

at 77 K based on a slit‐pore model (pore

diameter < 2nm) and a cylindrical pore model

(pore diameter > 2 nm)

• QSDFT, N2, carbon adsorption branch kernel at

77 K based on a slitpore model (pore diameter

< 2 nm) and cylindrical pore model (pore

diameter > 2 nm)

• QSDFT, N2, carbon adsorption branch kernel at

77 K based on a cylindrical pore model (pore

diameter < 5 nm) and spherical pore model

(pore diameter > 5 nm)

• QSDFT, N2, carbon adsorption branch kernel at

77 K based on a slitpore model (pore diameter

<2 nm) and a cylindrical pore model (pore

diameter 2-5 nm) and a spherical pore model

(pore diameter > 5 nm)

QuadraWin™ Data Reporting Capabilities

See Powder Technote #53 for complete NLDFT & QSFDT methods available.

Page 11: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

10

Software

The QUADRASORB evo TM analyzer is micro-processor controlled, and communicates with a Windows® Vista, 2000, XP or Window 7 based PC utilizing Quantachrome’s state-of-the-art, data acquisition and data reduction software, QuadraWinTM. A 21CFR Part 11 compliant software version is available for the pharmaceutical industry.

State-of-the-art

The QuadraWin™ software is powerful and user friendly. QuadraWin™ is superior for data reduction, incorporating the latest DFT (Density Functional Theory) models. The software guides you through analysis setup, data reduction, graphs and report printouts. During operation one can view the accumulated data, the isotherm and all associated graphs and analytical results up to that point. After a run, reports and graphs are printed automatically or you can use the software to determine the best fitting method, to compare data by overlaying curves or to adjust graph, size, scaling, titles, plot markers and line colors for best print out.

Data presentationA comprehensive range of surface area and pore size methods is available:

» Adsorption and desorption isotherms.

» Multi- and single point BET surface area. » Langmuir surface area.

» Mesopore size distributions (BJH and DH methods).

» t-method by deBoer, Halsey, carbon black (STSA).

» Alpha-s and MP micropore methods.

» Total pore volume, and average pore size.

» Dubinin-Radushkevich (DR) micropore surface area.

» Horvath-Kawazoe, (HK) Dubinin-Astakhov (DA) and Saito-Foley (SF) micropore methods.

» Extensive Density Functional Theory (DFT) library for unified micro and mesopore analysis using

N2, Ar and CO2.

» Fractal dimension by Frenkel-Halsey-Hill (FHH) or Neimark-Kiselev (NK) models.

Page 12: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

11

21 CFR Part 11 Software Features

21 CFR Part 11

The QUADRASORB evoTM, when configured for security and used with its 21 CFR Part 11 version of QuadraWinTM

software, is designed to allow the user to meet the regulatory requirements for electronic records within the pharmaceutical and allied industries as set forth by the US Food and Drug Administration (FDA). The FDA intends to enforce Part 11* compliance under FDA Regulations, the Federal Food, Drug, and Cosmetic Act and the Public Health Service Act as outlined in its 2003 Guidance for Industry “ Part 11, Electronic Records; Electronic Signatures - Scope and Application” prepared by the Office of Compliance in the Center for Drug Evaluation and Research (CDER). This version of the QUADRASORB evoTM software adopts software design features to allow for easy integration into pharma- ceutical and other GLP laboratories.

* Final Rule, Federal Register / Vol. 62, No. 54, pp13429-13466, 1997

Audit Trail Functions & Reporting Features

The audit trail does not obscure previous entries; old and new values are both recorded and visible. The audit trail itself cannot be edited and is included as part of the securely encoded data file it cannot become disconnected. Changes to meta-data require that the user enter a reason, to be in accordance with the underlying predicate record rules, which is then retained as part of the audit trail. The audit trail is included in all human readable formats, screen display, print preview, PDF and hard copy formats. Multiple page report sets are linked by a unique report i.d. generated automatically by QuadraWin™.

QuadraWin™-CFR Software

Functions Relating to System Access, Electronic Signatures and Security.

Required login with unique user i.d. / full name combination.

» Password aging and forced change.

» Automatic user account expiration and / or manual suspension.

» Selectable minimum i.d. and password length.

» Three user levels gives three privilege levels.

» Access level programmable by administrator level.

» Programmable session time-out (auto log-off through inactivity).

» Tamper resistant binary-encoded data files.

» Data security is established through the closed QUADRASORBTM / QuadraWin™ system.

» Data reduction parameters (metadata) used to calculate final results are included as part of the data file.

» “Operator” user level does not have the access privileges to change meta-data.

» Changes to meta-data are reflected in the audit trail.

» Data files acquired by means other than directly from the QUADRASORBTM instrument are flagged as such in the audit trail.

▶CFR Software- Audit Trail.

Includes many features that support these regulations and provide the necessary tools for customer compliance.

Visit www.quantachrome.com for more detailed instrument specifications and download brochures.

Page 13: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

12

Accessories

Regulator AssemblyProper Quadrasorb™ functioning is assured when high-quality gas regulators are used. Quantachrome supplies complete assemblies which include two stage regulators with dual gauges, cylinder connector, isolation valve and 1/8” gas line con- nector. The regulators feature metal, non-venting diaphragms and the appropriate CGA fitting for specific gases. Different assemblies are available for nitrogen (and other inerts including helium), hydrogen, carbon monoxide, oxidizing gases etc.

Vacuum Pump (standard applications) All vacuum volmetric gas sorption analyzers require a good vacuum pump and the QUADRASORB evoTM is no exception. The pump shall have the capability to pull an ultimate vacuum of 10 milli- torr or below. Quantachrome can supply the correctly sized pump complete with oil, hoses and fittings. You are not required to purchase the necessary vacuum pump from Quantachrome, but if you do, the entire system will have been qualified in our factory as a set, ensuring consistent performance.

Vacuum Pumps (krypton/micropore model)

Low pressure applications require a deeper vacuum that can only be achieved by a turbo- molecular pump. The turbo pump is included, and the correct backing pump can be supplied by Quantachrome either as a rotary oil pump or as an oil-free, dry diaphragm (membrane pump).

Storage DewarsFor the convenience of having larger quantities of liquefied gases on hand, Quantachrome offers storage dewars in sizes ranging from 5 liters to 30 liters, plus a transfer device and trolley for the largest size.

QUADRASORB evo TM

You are responsible for purchasing an instrument to meet your lab’s needs of today. Do you know what your lab’s needs will be five years from now?

Only the evoTM provides you the ability to meet your needs of today with the assurance that you can adapt and evolve to meet your needs of tomorrow without having to purchase an entirely new analyzer.

= adaptability

+

flexibility

evo=evolution

Page 14: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

13

Sample Preparation: Degassers

Consistent and reliable surface area and pore size results depend upon proper sample preparation procedures. In terms of B.E.T. analysis, the limitation in throughput is often sample preparation. The complete degassing of samples can often require several hours, while surface area measurements may require as little as 30 minutes.

Quantachrome manufactures several models of degassers to fulfill your sample preparation needs. These degassers provide a virtually continuous supply of properly prepared samples for the QUADRASORB evoTM Surface Area and Pore Size Analyzer.

The gold-standard in sample preparation for physi-sorption analyzers. It provides PC control of all heat-ing zones with individual heating ramps and times. The built-in cold trap enable efficient removal of condensables at low degassing temperatures and for a clean vacuum. Turbo- pumped version available for rapid high-vacuum degassing. Vacuum pump included.

Fully featured preparation unit. Individually heated stations with programmable heating profiles for R&D, commercial labs and multi-user laboratories. Dual modes (vacuum or flow) for further flexibility and optimization. Temperature control and logging via PC software (included). Integral cooling stations provide additional convenience.

Vacuum pump not included.

XeriPrep™ Degasser

MasterPrep™ Degasser

Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.

Page 15: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

QUADRASORB evo™

surface area & pore size analyzer

Su

rfa

ce

Are

a &

Po

re S

ize

14

Sample Preparation: Degassers

The FloVac provides cost effective vacuum degassing. Complete with single-zone heater (to 400°C), digital temperature controller and built-in digital vacuum gauge. Each sample station has its own adjustable evacuation / backfill rate control. Flow degassing is also possible and can be advantageous in removing large quantities of moisture prior to vacuum degassing. Individual cooling stations. PC Temperature Control Software included. Vacuum pump not included.

FloVac™ Degasser

The popular Flow Degasser has the same heating and cooling features as the FloVac but without vacuum capability. Ideal for quality control applications, teaching and start-up labs. Each sample station has its own adjustable flow rate control. PC Temperature Control Software included

Flow Degasser

# of Sample Ports ▶ 6 6 6 6

Heating Zones ▶ 1 1 6 (ovens) 6 (mantles)

Maximum Temperature ▶ 400°C 400°C 425°C

350°C (450°C with

optional high temperature

mantles for quartz cells)

Temperature Control Via PC ▶ Yes* Yes* Yes* Yes*

Flow Degas Mode ▶ Yes Yes Yes No

Vacuum Degas Model ▶ N/A Yes Yes Yes

Digital Vacuum Display ▶ N/A Yes Yes Yes

Cold Trap ▶ N/A No No Yes

Vacuum Pump ▶ N/ASold

Separately

Sold

Separately

Included(turbo pump optional)

Valve Type ▶ Mechanical Mechanical Mechanical Electric solenoid

DEGASSERS

Features Flow FloVac™ MasterPrep™ XeriPrep™

* Temperature Control via PC interface software controls and displays ramp rates, temperatures, and soak times for greater control and consistency of the sample preparation .

Page 16: Surface Area & Pore Size - IESMAT · surface area & pore size analyzer Surface Area & Pore Size » Available in both standard versions for BET surface area and mesopore size analysis,

The quality of Quantachrome’s after sales service support is the reason we are proud to maintain lifetime relationships with our customers.

Our global service staff assure you that Quantachrome Instruments will continue to be the reliable engines of material characterization laboratories. We offer you the flexibility of choosing from service contracts tailored to provide you with the response time, service package, and spare parts discounts that best fit your needs.

Quantachrome spare parts are certified to work with our instruments. We provide rapid response spare parts orders, and keep large inventories of replacement parts and hardware available.

Our fully equipped, state-of-the-art powder characterization laboratory, LabQMC (www.labqmc.quantachrome.com,[email protected]), provides the option of contracting for expert testing services. Laboratory services are also available to validate the applicability of our products prior to your purchase using your actual samples.

We view the field support of our instruments as an essential component of our business strategy. Our expert scientists are always available to answer questions on applications, or the use of our instruments. We do this as a standard service regardless of whether you have a service contract with us or not.

Quantachrome has a scientific research department consisting of world renowned experts in material characterization. Our staff, led by Dr. Matthias Thommes, conducts collaborative research projects with leading material research labs around the world. They regularly publish articles in leading peerreviewed journals, and speak at technical symposiums around the world.

Quality-Function-Dependability

Corporate Headquarters-USAQuantachrome Instruments1900 Corporate DriveBoynton Beach, FL 33426Tel: +1 800. 989 2476 | +1 561. 731.4999Fax: +1 561. 732.9888email: [email protected] w w. q u a nt a c h ro m e. co m

ChinaQuantachrome Representative Office w w w. q u a n t a c h r o m e . c o m . c ne m a i l : [email protected]: 400 650 1652 | +86 21 52828278

United KingdomQuantachrome UK Ltd. www.quantachrome.co.ukemail: [email protected]: +44 (0) 1252 819 719

GermanyQuantachrome GmbH & Co. KGw w w. q u a n t a c h r o m e . d eemail: [email protected]: +49 (0) 8134 93240

JapanQuantachrome Instruments Japan G.K.w w w. q u a nt a c h ro m e. co. j pemail: [email protected]: +81 44 829 1525

India Quantachrome Indiaw w w. q u a nt a c h ro m e. co memail: [email protected]: +91 22 2589 5858

Renowned innovator for today’s porous materials community.

For almost half a century Quantachrome’s scientists and engineers have revolutionized measurement techniques and designed instrumentation to enable the accurate, precise, and reliable characterization of powdered and porous materials. We have an unwavering commitment to providing state of the art technology, along with superior and unparalleled customer service and support. Our commitment to customers is to support you before, during, and after the sale throughout the lifetime of our instruments. This is a big commitment because our products are so robust and reliable that we regularly find many still in use for decades.