SureDesign v.1.2.1.15 Laura Pellegrino PhD...Designed for FFPE compatibility June 30, 2014...
Transcript of SureDesign v.1.2.1.15 Laura Pellegrino PhD...Designed for FFPE compatibility June 30, 2014...
1
SureDesign v.1.2.1.15
Laura Pellegrino PhD
SureDesign
Design with Confidence
• Modify existing catalog and custom designs
• Direct link to UCSC browser to review target regions
• Easily modify design settings (FFPE, stringency, etc.)
• Download .BED and design report
• Basic and advanced design options
June 30, 2014
Confidentiality Label
2
www.agilent.com/genomics/suredesign
Replaces eArray for DNA NGS/CGH custom design
BASIC DESIGN
June 30, 2014
Confidentiality Label
3
June 30, 2014
Confidentiality Label
4
Step 1: Define Design
June 30, 2014
Confidentiality Label
5
Haloplex
Step 2: Define Targets
June 30, 2014
Confidentiality Label
6
Step 3: Review Targets
June 30, 2014
Confidentiality Label
7
Direct links to UCSC Genome Browser
Step 4: Enter Parameters (only with Advantge Option)
June 30, 2014
Confidentiality Label
8
Step 5: Select probes
Step 6: Finalize
June 30, 2014
Confidentiality Label
9
June 30, 2014
Confidentiality Label
10
PDF Reports
Ways to Find Existing SureDesign Content
Expanded Search Capability
• Global search across applications, workgroups, and collaborations
• Search by design creator
June 30, 2014
Confidentiality Label
11
ADVANCED HALO DESIGN
June 30, 2014
Confidentiality Label
12
Halo Advanced Design Wizard (Ion and Illumina)
Define Design
• Library name, sequencing platform, read length, etc
Add / Review Content - LOOP
• Create one or more probe groups
– By Tiling
• Access to additional design parameters
– By Selecting Existing Probes
• Entire design
• Subset of a design
• List of amplicon IDs from a design
Finalize
• Design is available for quoting and ordering
June 30, 2014
Confidentiality Label
13
Read Length Parameter
• For Halo Illumina libraries only
• In Simple and Advanced wizards
• Choice of 100bp, 150bp or 250bp
• Probe selection algorithm is the
same for 100bp, 150bp and 250
read lengths
• Different coverage calculation
– to account for longer coverage
contribution per amplicon
needed for sequencing
June 30, 2014
Confidentiality Label
14
Read Length
June 30, 2014
Confidentiality Label
15
100bp 250bp
Add / Review Content – By Tiling
Same as tiling in HaloPlex simple design workflow
With access to additional design parameters
• Stringency
– Maximize Specificity, Balanced, or Maximize Coverage
• Optimize for Fragmented Samples
June 30, 2014
Confidentiality Label
16
Pseudogene designs
- Probe Stringency alteration
17
1. Maximize Specificity - Requires probe with only one unique hit in the
genome
2. Balanced – Allows selection of probes with 2 hits in the genome.
3. Maximize Coverage – Allows up to 5 hits in the genome.
Pseudogene Designs
- Probe Stringency Alteration
18
Balanced probe selection – 100% coverage of MYH6
Maximize specificity probe selection – 96.6% coverage of MYH6
SureDesign – FFPE Compatibility
19
For FFPE optimized designs
1. The design will include shorter fragments (50-400bp)
2. Both target polarities will be selected
Target Region Target Region
Normally fragments in the
range of 100-400bp are
used
For FFPE samples shorter
fragments (50-400bp) are
included
Standard design
Designed for FFPE compatibility
Exon Exon
FFPE design
One probe is targeting the sense and one the anti-sense strand of the target DNA
Sense
Strand
AntiSense
Strand
DNA TARGET FRAGMENT
Probes are designed for both target fragment polarities
• Improves capture efficiency
• Eliminate strand specific FFPE artifacts
Designed for FFPE compatibility
Designed for FFPE compatibility
June 30, 2014
Confidentiality Label
22
#chrom chromStart chromEnd name score strand
chr17 7565227 7565285 AM_175245_000003 1000 –
chr17 7565317 7565419 AM_175245_000002 1000 –
chr17 7565330 7565382 AM_175245_000001 1000 –
chr17 7569302 7569549 AM_175245_000008 1000 –
chr17 7569302 7569549 AM_175245_000007 1000 –
chr17 7569374 7569604 AM_175245_000004 1000 –
chr17 7569419 7569771 AM_175245_000006 1000 –
chr17 7569515 7569618 AM_175245_000005 1000 –
#chrom chromStart chromEnd name score strand
chr17 7565227 7565285 AM_719573_000005 1000 +
chr17 7565227 7565285 AM_719573_000004 1000 –
chr17 7565317 7565419 AM_719573_000001 1000 –
chr17 7565318 7565420 AM_719573_000003 1000 +
chr17 7565326 7565382 AM_719573_000002 1000 +
chr17 7569300 7569549 AM_719573_000012 1000 +
chr17 7569300 7569549 AM_719573_000011 1000 +
chr17 7569302 7569549 AM_719573_000014 1000 –
Standard FFPE
SureDesign – Ion Torrent vs Illumina
23
Polarities
Illumina: Probes are selected on one of the two
polarities of the region targeted
(PE sequencing)
Ion Torrent: Probes are selected on both polarities
(SE sequencing) Pseudo PE Sequencing
Capacities
Illumina: Up to 5 MB
Ion Torrent: Up to 2.5 MB
Add / Review Content – Selecting Existing Probes
Options are to choose:
• One design / probegroup
• Subset of one design / probegroup
June 30, 2014
Confidentiality Label
24
Exon 1 Exon 2
• All HaloPlex exome probes overlapping with defined targets will be selected
• Exome probes do not exist for non-coding regions, none will be selected for
these regions
SureDesign
Use amplicons from other probe groups (ex: HaloPlex Exome)
1. Define target regions
2. Use all exome probes for coding regions
3. Combine with custom design for non coding regions
Questions and Live Demo
June 30, 2014
Confidentiality Label
33
www.agilent.com/genomics/suredesign