ID System Client Date Hour
19 QCX360 Lafarge PLN Fr 100310 15H45 1.5 ASA
18 QCX782 Lafarge Le havre Fr JC. Fayolle 100310 1 ASA
17 Ass-Tel QCX782 Lafarge Le havre Fr JC. Fayolle 100308 13H15 0.5 ASA
16 Ass-Tel QCX782 Lafarge Le havre Fr JC. Fayolle 100303 17H25 0.75 ASA
15 QCX360 Lafarge PLN Fr 100303 9H30 1 ASA
14 Ass-tel QCX360 Lafarge PLN Fr Guy Garcia 100302 16h05 0.5 ASA
13 QCX360 Lafarge PLN Fr Barbier 100301 15h30 1.5 ASA
12 Ass-tel QCX360 Lafarge PLN Fr Guy Garcia 100225 15h30 1 ASA
11 Ass-tel QCX360 Lafarge PLN Fr 100225 10h00 0.5 ASA
10 Ass-tel QCX360 Lafarge PLN Fr Guy Garcia 100224 15h20 0.5 ASA
9 Ass-tel QCX360 Lafarge PLN Fr Barbier 100219 16H30 0.5 ASA8 Ass-tel QCX360 Lafarge PLN Fr Barbier 100219 14H15 0.5 ASA
7 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 100217 22h05 0.5 ASA
6 Ass-tel QCX360 Lafarge PLN Fr Guy Garcia 100202 15H15 0.5 ASA
Support type
Site / Country
Client Pers
T. Spent (H)
FLSA eng
Bomgar RemoteAccess
Mr Barbie/Mr Camous (Contes)
Bomgar RemoteAccess
11H30 Et 14h15
Bomgar RemoteAccess
Claire Niermont/Mr Camous (Contes)
Bomgar RemoteAccess
Mme Lopez & Mr Garcia
5 Ass-tel QCX360 Lafarge PLN Fr Barbier 100127 11H15 0.75 ASA
4 e-mail QCX360 Lafarge PLN Fr Barbier 100126 17h30 0.25 ASA
3 Ass-tel QCX360 Lafarge PLN Fr 100126 14h45 0.5 ASA
2 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 100122 14H20 0.5 ASA
1 Site Visit QCX427 Lafarge SPLC Fr 100118 14 ASA
Claire Niermont
Choupay/Landais
Support Description
Pb capteur presence pastille coté FX
Connexion à distance via l'usine de Contes la modification effectué le 1/3 n'a pas résolu le Pb. Modif à nouveau
Pb sur le Synop, sur le prelv Melange un message "Manque condition initiale" et la couleur de l'échantillonneur en Bleu". Les points qui anniment ces symboles ont été supprimés !!, récréation des point concerné. Pb résolu.
Pb Insitec. Après une augmentation de la dose (de 17 à 40g) pour pour l'analyse Insitec, nous constatons plus de défauts bien que l'analyse se termine bien. Les raisons peuvent être soit Timeout soit un défaut qui se déclare pour un court instant sur l'appareil (vue auparavant). une première action de augmenter le timeout à 400 ou 500 sec. aprés augmentation à 500 sec, le défaut n'aparait plus.
Les éch Auto (Clinker) ne sont plus enregistrés. La cartouche arrive à la station Recp se vidange mais on ne dose pas cas l'ech n'est pas enreg. Après re-boot, le PB disparait, le diag sur les signaux AST et SST auipourraient être la cause
Connexion à distance via l'usine de Contes mise en place de la correction du driver effectuée il y a 2 jours, les test seront effectué durant la journée
Comment modifier le timeout du programme Malvern (PGM_Param(2) fortran ) #150
Pb1) Modif à distance du Prgramme DX concerné par le PB de la semaine dernière.vu l'heure tardive nous n'avons pas mis en place la solution. Nous feron demain. Pb2) De temps en temps une perte de comm avec toutes les machines, ceci s'est produit vers 14h aujourd'hui. aprés Investigations des messages "Collision excessives" sont générés ce qui indique un pb réseau ponctuel.
après contact avec Mr Granacher et envoie des traces il apparait que QCX envoie la demande des résultat avec format KPc, après dignostic nous decouverons su'il s'agit d'une bUg dans QCX, qui se produit suite à un monieur bien particulier.la redémarrage du driver regle le PB. une correction du driver doit être effectué la semaine suivante.
les traces envoyées montrent que le PC Bruker envoie les resultats en Kcp. Donc c'est un pb de paramètrage qui a changé dans le logiciel de Bruker (probablement après la calibration). Envoie par e-mail les coordonnées Mr Granacher qui a dévelppé la partie AXSCOM.
Pb depuis la matiné les résultas FX dans QCX sont en Kpc et non pas en pourcentage. Bruker a verifié à distance ne decèle pas d'anomalie côté PC Bruker. Demade d'eeffectuer des traces de comm et d'envoyer par e-mail.
Patille arrive au bout du conv coté FX mais Analyse ne demarre pas. PB de sequence non terminé auparavat au niveau de convoyeur (Pb d'automatisme qui arrive rarement). La solution est faire fonctionner le convoyeur manuellement sens FX vers Robot avec la pastille.
Pb Defaut Comm Modbus, sur les aiguilleurs et les échantilloneurs. Reboot QCX/Automates etc… n'a pas resolu le PB. Pb liaison Comm / cartes modem cables etc à verifier
les resultats des analyses du nouveau produit (Nv GrpEch) ne sont pas transmis à Protop. Il faut configurer les exports C-Points pour ce nouveau Produit.
Info sur les cartes de contrôle et l'utilisation des Apoints à cet effet
Suite PMV See PMV Site Report
Info comment integrer nouveau produit en Automatique, Grp Ech, AutoEch, Bpoint Alg, etc …
PB de comm avec les machines Labo et Protop/ reboot QCX OK, un diagnostic approfondit n'est pas possible, avec les alarmes communiqué, il semble que ce soit un pb de micro coupure réseau
pb au niveau DX, Ech arrive ext convoyeur mais analyse ne démarre pas. Apres RAZ, Idem, DX se met en Défaut. Solution : sur le PC DX vider la liste d'ancien Ech non supprimé. OK
Support_ID System Client Date Hour
S090213FR-ASA02 Ass-tel QCX782 Lafarge Le havre Fr 090213 11h30 0.5
S090213FR-ASA01 Remote QCX354 Lafarge Contes Fr 090213 10H00 1.25
S090415FR-ASA01 Ass-tel QCX360 Lafarge PLN Fr Barbier 090415 14H45 0.5S090529FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 090529 12H00 0.5
S090605FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 090605 16H30 1S090608FR-ASA01 PMV QCX782 Lafarge Le havre Fr P.Legros 090608 35
S090616FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr 090616 14
S090619FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr 090619 7
S090619FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr 090623 7
S090213FR-ASA02 Ass-tel QCX782 Lafarge Le havre Fr Fayolle 090626 20H45 0.5
S090703FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr 090703 7
S090728FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr 090728 7
S090803FR-ASA01 PMV QCX354 Lafarge Contes Fr 090803 35S090911FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr Choupay 090911 7
S090928FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr 090914 7S090911FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr Choupay 090928 7
S091001FR-ASA01 Ass-tel QCX782 Lafarge Le havre Fr P.Legros 091001 19h15 2
S091017FR-ASA01 Ass-tel QCX782 Lafarge Le havre Fr P.Legros 091017 17h00 1S091021FR-ASA02 Ass-tel QCX360 Lafarge PLN Fr Barbier 091021 14h30 0.5S091001FR-ASA01 Ass-tel QCX782 Lafarge Le havre Fr P.Legros 091021 11h00 0.5
Site Visit QCX782 Lafarge Le havre Fr 091116 49PMV QCX427 Lafarge SPLC Fr Choupay 091214 28PMV QCX360 Lafarge PLN Fr Barbier 091221 28
Site Visit QCX782 Lafarge Le havre Fr 091202 42
Site Visit QCX782 Lafarge Le havre Fr 090707 7
Site Visit QCX782 Lafarge Le havre Fr 090730 7
Site Visit QCX782 Lafarge Le havre Fr 090914 7
Support type
Site / Country
Client Pers
T. Spent (H)
P.Legros/Fayolle
G. Camous
J.C. Fayolle
J.C. Fayolle
J.C. Fayolle
J.C. Fayolle
J.C. Fayolle
G. Camous & J.M Jover
J.C. Fayolle
J.C. Fayolle
J.C. Fayolle
J.C. Fayolle
J.C. Fayolle
J.C. Fayolle
Site Visit QCX782 Lafarge Le havre Fr 100106 21J.C. Fayolle
Support Description crédit jours371 53
ASA Usine
ASA Contes
ASA PLNASA Info sur la recup des resultas au dela de 2 ans SPLC
ASA Le Havre ASA PMV See Site report
ASA QCX Client Install & various
ASA QCX Client Install & various
ASA Robolab trouble shooting / Trace Install etc …
ASA PB avec Robolab, blocage malgré 2 reboots. Origine du PB Robot hors cercle
ASA Latest QCX Client
ASA Robolab Diagnostic (after Server Virus contamination)
ASA See PMV Report
ASA diagnostic on Sampler PB alarm.
ASA Trace on Robot Dirver / autamatic backup of SDREvents
ASA Pb Autoech non valid BP50/Export to Protop/ Boucl
ASA
ASAASA diagnostic concernant PB Comm entre QCX et XRF Bruker
ASA téléchargement des fichiers d'alarmes sur plusieur jour pour diagnostic
Jesper Problem with TTR
ASAASA
Christophe, rené
LDo
LDo
LDo
FLSA eng
Crédit heures
Some of XRD results are not transfered to Protop. In some sgp not transfer for QIMS. Indication for XRD transfert, deeper invistigation is needed for QIMS
New application under supperQ does not start from QCX. Dignostic using BOMGAR remote connection. The application was bad configured under SuperQ. Correction OK
After having problem with Brucker XRF during analysis, need to know how to trace communication. Information given. PB solved.
PB With Extra smp for average & smp in rcv/ cancel of etra smp, restart extra smp driver; Rcv does not reset (the clean) the robot did not removed the cup from balance, once removed manual it is OK.
PB Robolab, certain appli trop long à s'afficher voir non. Reboot OK, mais ech. Non traité parés vidange cartouch. Type Godet non detect. Rredef. Poid petit Gd. + marge
bp de ralentissement su system. Après reboot et chg de srv 2 eqp "n'acrrochent pas" reverif connecteur Moxa & rebbot OK
Jesper
jours utilisés327.5 46.79 6.21
heures utilisées
35
28.542
222
heures utilisées
jours restants
Support_ID System Client Date Hour
S081204FR-ASA01 Site Visit ECS511 Rouen Fr 081204 7
S081201FR-ASA01 PMV QCX427 Lafarge SPLC Fr Choupay 081201 2 5 6 8 35
S081124FR-ASA01 Ass-tel QCX360 Lafarge PLN Fr 081124 1
S081009FR-ASA01 Remote/BOM QCX1254 Holcim Viverge 081009 13H 0.5
S081008FR-ASA01 Ass-tel QCX360 Lafarge PLN Fr 081008 3
S081007FR-ASA02 Site Visit QCX427 Lafarge SPLC Fr Caillière 081007 18H45 0.5
S081007FR-ASA01 Ass-tel QCX360 Lafarge PLN Fr Barbier 081007 10h 1
S081002FR-ASA01 Ass-tel QCX360 Lafarge PLN Fr 081002 10h 0.75
S080923FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr Caillière 080923 0.5
S080902FR-ASA01 PMV QCX360 Lafarge PLN Fr 080902 21S080825FR-ASA01 PMV QCX782 Lafarge Le havre Fr P.Legros 080825 35
S080724FR-ASA01 Ass-tel QCX354 Lafarge Contes Fr 080724 1
S080722FR-ASA01 Site Visit QCX354 Lafarge Contes Fr G. Camous 080722 11
S080717FR-ASA02 Ass-Tel ECS1059 AKBOUR 080717 10H&17H 1
S080717FR-ASA01 Remote/BOM QCX1254 Holcim Rochefort Fr Viverge 080717 1
S080715FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr P.Legros 080715 12
S080713FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080713 Sunda 2.5
S080711FR-ASA01 Remote c QCX354 Lafarge Contes Fr 080711 7
S080708FR-ASA01 Site Visit QCX1254 Holcim Rochefort Fr 080708 24
S080702FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080702 18H00 0.5
S080627FR-ASA01 PMV ECS511 Rouen Fr 080627 7
S080623FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr 080623 8
Support type
Site / Country
Client Pers
T. Spent (H)
SNVE-Smedar
M. Delorme
G. Garcia & Barbier
10h & 14h
Rochefort Fr
Barbier & Gomez
11H&14H
G. Garcia & Gaubert
G. Garcia & Barbier
G. Camous 10h&15h&16h
Cimar (italcementi)
AGDIR Morocco
14H00&20H
G. Camous
Mme Dacosta, MM Viverge, Menetrier
SNVE-Smedar
M. Delorme
Landais/ Caillière
S080616FR-ASA01 Site Visit QCX354 Lafarge Contes Fr 080616 35
S080606FR-ASA03 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080606 19H00 0.5
S080606FR-ASA02 Ass-Tel ECS1058 Safi Morocco Aroui 080606 17H 2
S080606FR-ASA01 e-mail ECS511 SNVE Rouen Fr 080606 9H30 0.5
S080605FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr 080605 8
S080604FR-ASA02 Ass-Tel ECS1058 Safi Morocco Aroui 080604 14H 1
S080604FR-ASA01 Ass-Tel QCX427 Lafarge SPLC Fr 080604 0.5
S080526FR-ASA01 e-mail/diag ECS/PLG113 Nevers FR 080526 11H 1
S080502FR-ASA01 Ass-Tel ECS1058 Safi Morocco Aroui 080502 17H00 1
S080414FR-ASA01 Ass-Tel ECS1058 Aroui 080414 16H45 0.5
S080408FR-ASA01 Ass-Tel QCX427 Lafarge SPLC Fr 080408 9h:15 1
S080328FR-ASA01 Ass-Tel QCX573 Marwahi 080328 14h15 1
S080327FR-ASA01 Ass-Tel QCX573 Marwahi 080327 14h 4
S080326FR-ASA01 Ass-Tel QCX573 Marwahi 080326 14h15 1
S080321FR-ASA01 Remote co QCX782 Lafarge Le havre Fr 080321 10h:30 0.5
S080319FR-ASA01 Site Visit QCX782 Lafarge Le havre Fr 080319 7
S080318FR-ASA01 Ass-Tel ECS1058 Safi Morocco Aroui 080318 11H30 0.5
S080317FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr Choupay 080317 7
S080317FR-CCD01 E-mail QCX1254 Holcim Rochefort Fr Menetrier 080317
G. Camous & J.M Jover
Cimar (italcementi)
Ludovic Lesage
Landais/ Sandrine Legros
Cimar (italcementi)
Sandrine Legros
11h et 14h
Onyx / Sonirval
Flore Mateta
Cimar (italcementi)
Cimar (italcementi)
Safi Morocco
Eric Landais
Holcim Maroc
FEZ Morocco
Holcim Maroc
FEZ Morocco
Holcim Maroc
FEZ Morocco
FAYOLLE/Toupin
FAYOLLE/Toupin
Cimar (italcementi)
S080312FR-ASA01 Ass-Tel ECS1058 Safi Morocco Aroui 080312 14H 1
S080311FR-ASA01 QCX1254 Holcim Rochefort Fr 080311 09h:15 2
S080307FR-ASA01 QCX1254 Holcim Rochefort Fr 080307 11h:45 1
S080306FR-ASA01 QCX1254 Holcim Rochefort Fr 080306 15h:00 1S080305FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr Landais 080305 7
S080303FR-ASA02 QCX1254 Holcim Rochefort Fr 080303 11h:05
S080303FR-ASA01 QCX782 Lafarge Le havre Fr FAYOLLE 080303 10h:00
S080302FR-ASA01 Ass-Tel QCX1254 Holcim 080302 18h05 1.5
S080227FR-ASA02 QCX1254 Holcim Rochefort Fr Menetrier 080227 14h00 1
S080227FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080227 16h:20 0.5
S080226FR-ASA02 e-mail ECS1059 080226 16H00 0.5
S080226FR-ASA01 QCX1254 Holcim Rochefort Fr 080226 17h00 2
S080215FR-ASA01 Site Visit QCX1254 Holcim Rochefort Fr Mr Cassez 080215 14h00 1
S080212FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr 080212 7
S080205FR-ASA02 Ass-Tel QCX573 Marwahi 080205 19h15 1
S080205FR-ASA01 Ass-Tel QCX573 Marwahi 080205 14h45 0.5
S080201FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080201 16h:20 0.5
S080131FR-ASA01 Ass-Tel QCX1254 Holcim Rochefort Fr 080131 15h:00 0.5
S080127FR-ASA01 QCX1254 Holcim-IT 080127 3
S080124FR-ASA01 Site Visit QCX427 Lafarge SPLC Fr Mr Landais 080124 7
Cimar (italcementi)
Mr Viverge & Menetrier
Mr Viverge & Menetrier
Mr Viverge
Mr Viverge
Rochefort Fr
Mr Viverge
Cimar (italcementi)
Agadir Morocco
Mr Akbour & Taji
Mr Viverge & Menetrier
Choupay/Landais
Holcim Maroc
FEZ Morocco
Holcim Maroc
FEZ Morocco
Mme Dacosta & Mr Cassez
Lille, Rochefort Fr
MM Marino & Dacosta & Viverge
S080123FR-ASA01 various QCX1254 Holcim Rochefort Fr 080123 2
S080117FR-ASA03 e-mail QCX782 Lafarge Le havre Fr FAYOLLE 080117 18:15 0.5
S080117FR-ASA02 Ass-Tel ECS1059 Mr Akbour 080117 1.5
S080117FR-ASA01 Ass-Tel QCX427 Lafarge SPLC Fr 080117 0
S080116FR-ASA03 Ass-Tel QCX427 Lafarge SPLC Fr Mr Landais 080116 0
S080116FR-ASA02 e-mail QCX782 Lafarge Le havre Fr FAYOLLE 080116 19:00 1
S080116FR-ASA01 Ass-Tel QCX1254 Holcim Rochefort Fr 080116 10:30 1
S080114/15/16FR-ASA01 QCX1254 Holcim-IT 080114/15/16 8
S080115FR-ASA01 Ass-Tel QCX985 Mr Djebbi 080115 15:15 1.5S080109FR-ASA01 Ass-Tel QCX360 Lafarge PLN Fr G. Garcia 080109 10:30 0.5S080107FR-ASA02 Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080104 21:45 0
S080107FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080104 18:00 2S080104FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080104 11:00 0.5
Viverge, Cassez & Menetrier
Cimar (italcementi)
Agadir Morocco
16H15 and
17H45
Mme Choupay
y; Menetrier
Lille, Rochefort Fr
MM Marino & Dacosta
CJO (CIMPOR)
Djebel Oust Tunisia
Support Description
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA VISITE ANNUELLE 3 jours
ASA PMV See Site report
ASA
ASA Résolution PB Drivers FX
ASA PB on IPModbus converter/ how to reset etc …
ASA
ASA
ASA Troubleshooting of the Robot Problem
ASA Troubleshooting of the XRF new driver
ASA PMV 3 days See site report
ASA
ASA PMV On VMS system
ASA
FLSA eng
urgent intervention : MOP1 stopped and will not restart (disk space problem), reboot on VMS CD, check of the disk files, one of system log file has huge amount of data. After file deletion system OK again
PMV XRF Driver Modification to use Cubix as spare XRF + normal system control
during the WE after changing product type for cement the analysis stops after about one Min. it is OK for clinckr and RM. From the trace QCX cancel the analysis after about 1 min. the origin of the problem is timeout definition, it looks like it has been
Since last week, almost 2 time per day, the Opstation on the client Freez, we must restart OPS to solve it. We have to check if it is HF pb
ASA & COE
Establishement of a remote connction (BOMGAR) to Debug and see itf the Bruker Pb is From QCX. Conclusion thePB is in Brucker side.
after some work on the pC XRF the communication is lost between , will not be back again. Aftre re-starting the driver OK
PB have not been solved bruker did not do any investigation. We got communication trace, the XRF at the end of the analysis send permanaetely, it is being moving sample to the belt
Pb Bruker, Sample analysed uploaded to internal Pos but not to the belt. Manual samples from rack are OK. Our dignostic Bruker PB
XRD Eqp had HW pb during Weekend, after panalytical intervention the PB has been fixed. But from QCX analysis will not start. After restating the driver Teins4 it is OK
diagnostic et info pour résoudre 1- pb transmission Pfmanu à Unilab. 2- Remplacement lecteur Cassette
after power cut the TTR drivers are in fault. After investigation the TTR have been Put in Manual. Once swithched back to Auto PB Salved
diagnostic pour le problème Robot survenu le wwek-end. Finalement c'était un PB de mauvaise sycronisation.
Info, Clincker result has not been transmited to CCR. The reason is a sample have been taken befor last clinker sample analyzed
Test to repreduce problem happening June 4. usage of 4 portion per sample. In the begining of the afternoon the PB happened. DB put back, recommendation to a avoid 4 portions use
ASA Visite annulelle dans le cadre du contrat de maintenance
ASA
ASA Help on rebuilding the arriere server by using import/export method.
ASA Info about using optical mouse, on POP (VMS) under WinNT
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA Question on how to put back old mimic. E-mail description sent.
ASA
CCD
The operators says that some time when changing sample taking frequency it is not respected by the system. Explanation may be for a given sample we have to change the frequency for all sample group (product) of the sampler and not anly the current one.
Solving Predosing PB. the PB has become serious yesterday aftrnoon. the plant decided to use the image disk made one month ago. This worked OK. so my work was to investigate what happened yesterday. we put the suspected disk on disconnected spare machine.
TS ECS carrière server, the installation of new server with Backup, Comm to PLC have PB. Serveral test and investigation PB Not solved.
Dosing/deviding PB on the predoser. Since the morining one predose machine, does not dose some or all the portion. Check of the comM, events etc.. After reboot the PB remain. Urgent intervention the to do the following day.
The client asks if possible to get statistical data fro octobre 2007, for points not declared in PLG. After investigation, Hourly stat data do cover only 2 months.
Test of the remote connection Through the secure server in Copenhagen, using BOMGAR
Problem on Server Synchronisation. Synchro failed. Finaly we did backup from server1 and restore on server2 OK
PB en Result transfer to QIMS on some of SGP. This was due to changes on XRF1 and XRF2 for (tablet and bead). Explanation on where to change config.
the QCX system is Freeze with no mouse nor keyboard active, with alarm set time error (at 28 march 02hxx.) Reboot, and change to system time to the local morrocan time
After long investigation, the PB is because the ethernet connec is set to twisted pair not BNC. Modification done (>>>set ewa0_mode BNC) comm OK with XRF & PLC. Still pb in the Eqp itself the client will contact Thermo to fix the eqp HW pb
The client recived today the new QCX server sent by KBH, It starts OK, but no comm with XRF nor PLC's various investigation, agreement to continue investigation tomorrow
Test of the remote connection Through the secure server in Copenhagen, using BOMGAR
1- Discussion on spec for Feeder acsh Estimation, based on complicated
calculation. 2- Discussion on how to improve the diagnostic when pb in the Recv
Station 3- B-Points for Eqp availability as part of new performance reports
Work with panalitical reducing analysis time, espcialy sampling handle in the changer
e-mail bug origin of AUS Pb is in one faceplate, description how to fix it. Mr Menetrier made the modif. OK
ASA Several calls for how to change passwords for administatives accounts
ASA
ASA
ASA Test remote connexion to the site using BOMGAR. Sucess OK
ASA Transfert PB between XRD Sgp Data and Protop. Solved
ASA
ASA
ASA
ASA
ASA
ASA Send TOP 50 alarms & manual how to change Mac Adress
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA
ASA Check and test new spare QCX Server
Implementation by remote connection of B Pnts for Status Eqp for KPI, BpAlg, Bpnts and log horizon.
PB AUS the transport system showing as a carrier is in the tubes with red sign. The client does think it is sensor PB. He asked for CCD diagnostic, trough remote connection. Finaly the client succeed to solve the PB by lookin in the PLC. Mr Menetier sent
The client is complaining he odered spar parts from Pfaff since Otober 2007, he did not recieve any thing yet. Phone number of GGR is given to do the necessary
JCF suggests a meeting in site to discuss the complecated calculation. We agree for 19/3/08 in the morning
Since Friday Night no possibility to analyse on the Axios from QCX. Comm look to be OK, after investigation and trace etc … we find out that the defined bacth list in SuperQ is corrupted. Creation of new list (QCX_LIST1) and modification in QCX driver par
Upgrade of Mill and Press drivers + faceplates. Discussion on BLX behavior, and modification of the virtual silo capacity from 500t to 400t
Discussion on problem happend on RCV & Balance and TTR. What is the possibility to intreuce more info in the OPS RCV etc to help for diagnostic. Also disscussion on some complicated calculation needed in the plant, the possibility of making a specific app
BOMGAR FLSA office Test and manual writing on how to use in the client side. E-mail sent for real with the site tomorrow
Finding the requested info from various document and sending them by e-mai to Mr Cassez
XRD Driver Modification to get both results from Pic & Rietveld simulanousely. Also Work on Data export to Protop
after dedusting CD Device problem not solved. Checking of the system description file SCSIdisk, CD and Tape drives. No of the usual drive names dka .. Is shown. Investigation on the shown drives, information on internet. First diagnostic, SCSI board is do
QCX Server (VMS) does not start. Diagnostic and try to boot on the CD fail. Ask to dedust the CD drive and call back
TTR shows status not updated. Check Modicon TTR PLC, No comm. Ping to TTR IP Adress OK. Check visualy the PLC looks OK. After swich off and on the TTR, Comm back OK
Mr Cassez asks to be supplyed on info on QCX connection to the ABB LIMS at the site. He will make a presentation on internal Holcim Comfrence. Promise to supply sth next week
Conf and test of DSL line as suggested by the client to test VPN, without success. E-mail to the client about the result.
ASA
ASA study the possibility to make some specific complicated calculation with QCX
ASA
ASA
ASA
ASA
ASA
ASA Trying to configure and establish a VPN connection to the Rochefort site
ASAASA Infor about prg nbr for the Malvern, the client changed the Eqp to Insitec
ASA Call back for confirmation system is OK
ASAASA Info pour des calculs compliqué (Solveur)
1- Contact with Pfaff to arrange Pfaff 2007 service visit 2- download and extraction drivers (mill and press) and send only exe and faceplates. 3- email to the client with these info including info that we are going to develop new KPI
Help on restoring (after rebuilding the Server) ECS DB Cement Dispatch ECS Server.
coordination for XRF replacement. Info for normal (not Reiveld) FCaO on the XRD
Discussion for how to build a spare VMS QCX Server. Plan intervention in site to help on this January 24
e-mail answer/diagnostic about PB of 07/01/08. See Report PB_Lehavre_080107_diagnostic_email_a_JCF.doc
It looks like one of the disks -mirror- is faulty (led blinking) (E0D76 BP Drive 1), various check, and info from MBH. The faulty disk has to be changed. Suggestion to the client to have and extra disk for Backup (image). As the disks are Hot swap
The client is worry about disk free space on QCX Server, and some strange application trying to start on the machine. General check done, free space OK, but it looks that some virus passed there. Even as administrator ther was no possibility to access the
Robolab : Big cup is not moved to the rack, this lock the recipe in the Recv Station. Stopping the BC driver freeze Eqp Tools. Reboot did not help, sample stays in RCV,not treated. Err PM, (we find PM service stopped), clean non finished recipe reboot aga
Support_ID System Client Date Hour
S071207FR-ASA01Ass-Tel ECS1059 AKBOUR 071207 11:00 1 ASA
S071206FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr 071128 17h ASA
S071206FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr 071206 11h/14h 1.5 ASA
S071205FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 071205 15h/17h 1 ASA
S071205FR-ASA01PMV QCX427 Lafarge SPLC Fr 071205 14 ASA
S071204FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr 071204 3 ASA
S071203FR-ASA01PMV QCX427 Lafarge SPLC Fr 071203 7 ASA
S071128FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 071128 10H 0 ASA
S071126FR-ASA01Ass-Tel QCX354 Lafarge Contes Fr G. Camous 071126 11H 0.5 ASA
S071125FR-ASA01Ass-Tel ECS1058 Safi Morocco Aroui 071125 14H 0.5 ASA
S071120FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 071120 10h 0.5 ASA
S071107FR-ASA01Ass-Tel QCX??? Sean-quinn Irland 071107 15h 1 ASA
S071107FR-ASA01PMV QCX427 Lafarge SPLC Fr 0709&0 14 ASA
S071106FR-ASA01Investgation QCX??? Sean-quinn Irland 071106 1 ASA
S071105FR-ASA01Remote co;, QCX803 Germany 071105 10 & 15 3 ASA
S071031FR-ASA01Ass-Tel QCX803 Germany 071031 3 ASA
S071024FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 071024 9:00 ASA
Support type
Site / Country
Client Pers
T. Spent (H)
FLSA eng
Cimar (italcementi)
Agadir Morocco
FAYOLLE / TOUPIN
y; Menetrier/ Viverge
Mme Choupay & Cailliere
y; Menetrier/ Cassez
Mme Choupay & Cailliere
Cimar (italcementi)
Don Mcdonald
Mme Choupay & Cailliere
Rohrdorf-Zement
Frank Stocker
Rohrdorf-Zement
Frank Stocker
S071023FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr Legros 071023 20:00 1.5 ASA
S071010FR-ASA01Ass-Tel ECS1059 Taji 071010 9:00 7 ASA
S071009FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr 071009 14:10 0.5 ASA
S071009FR-ASA01Ass-Tel ECS1059 Taji 071009 9:00 7 ASA
S071008FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 071008 19:35 0.5 ASA
S071008FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 071008 17:05 0.5 ASA
S070928FR-ASA01Ass-Tel QCX427 Lafarge SPLC Fr 070928 15:30 1 ASA
S070924FR-ASA01Site Visit QCX782 Lafarge Le havre Fr 070924 35 ASA
S070919FR-ASA01Ass-Tel ECS Abbeville Fr 070919 0.5 ASA
S070918FR-ASA01Site Visit QCX427 Lafarge SPLC Fr 0709&0 7 ASA
S070912FR-ASA01Site Visit QCX1254 Holcim Rochefort Fr 070912 … 21 ASA
S070910FR-ASA01Site Visit QCX427 Lafarge SPLC Fr 0709&0 7 ASA
S070907FR-ASA01Site Visit QCX427 Lafarge SPLC Fr 070907 7 ASA
S070906FR-ASA01Site Visit QCX427 Lafarge SPLC Fr 070906 7 ASA
S070905FR-ASA01Ass-Tel QCX360 Lafarge PLN Fr 070905 ASA
S070904FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr 070904 … 3 ASA
S070829FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070829 … 2 ASA
S070828FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070828 14:00 2 ASA
S070827FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070827 8:45 0.5 ASA
S070822FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070822 9:30 0.5 ASA
S070810FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070810 9:20 0.5 ASA
S070809FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070809 11:35 0.5 ASA
S070717FR-ASA01Site Visit QCX782 Lafarge Le havre Fr 070717 28 ASA
Cimar (italcementi)
Agadir Morocco
y; Menetrier
Cimar (italcementi)
Agadir Morocco
Mme Sandrine
Legros
FAYOLLE & Legros
Tereos (Beghin Say) Mr Boucher
Mme Choupay & Cailliere
L. Casser y; Menetrier
Mme Choupay & Landais
Mr Vialle & Landais
Mr Vialle & Landais
Mme Laetitia Lopez
P. Viverge & yannick
FAYOLLE & Legros
S070716FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr Yannick 070716 15:30 0.5 ASA
S070709FR-ASA03Ass-Tel QCX1080 UNILAND 070709 13:30 1 ASA
S070709FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr 070709 15:10 0.5 ASA
S070709FR-ASA01PMV QCX360 Lafarge PLN Fr 070709 24 ASA
S070705FR-ASA05Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 070705 9:35 0.5 ASA
S070701FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070701 14:10 1 ASA
S070628FR-ASA01Site Visit PLG1292 Rouen Fr 070628 7 ASA
S070626FR-ASA01Site Visit PLG1292 Rouen Fr 070626 7 ASA
S070618FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070618 14:10 0.5 ASA
S070611FR-ASA01Site Visit QCX354 Lafarge Contes Fr 070611 35 ASA
S070601FR-ASA01Ass-Tel QCX1080 UNILAND 070601 14:00 1.5 ASA
S070516FR-ASA06Ass-Tel QCX782 Lafarge Le havre Fr 070516 20:10 1.5 ASA
S070516FR-ASA05Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 070516 16:35 0.5 ASA
S070516FR-ASA04Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070516 15:15 0.5 ASA
S070516FR-ASA03Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 070516 14:40 0.5 ASA
S070516FR-ASA02Ass-Tel QCX427 Lafarge SPLC Fr Mr Vialle 070516 11:20 0.5 ASA
S070516FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070516 9:10 0.5 ASA
S070515FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070515 16:20 1 ASA
S070515FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070515 9:15 0.5 ASA
S070514FR-ASA03Ass-Tel QCX1080 UNILAND 070514 10:30 2 ASA
S070514FR-ASA03Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070515 19:30 1 ASA
S070514FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070514 14:00 0.5 ASA
Vallcarca (Spain)
Ruben Garcia
Mr Cassez & Yannick
G. Garcia & Barbier
SNVE-Smedar
M. Delorme
SNVE-Smedar
M. Delorme
G. Camous & J.M Jover
Vallcarca (Spain)
Santi RAYA & Lucio
LeGros et Michelo
Vallcarca (Spain)
Santi RAYA & Ruben Garcia
S070514FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070514 10:00 0.5 ASA
S070511FR-ASA01Site Visit ECS/PLG113 Nevers FR J. Fournier 070511 7 ASA
S070510FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070510 14:00 0.5 ASA
S070424FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 070424 16:45 0.5 ASA
S070424FR-ASA01Ass-Tel ECS/PLG113 Nevers FR J. Fournier 070424 15:00 1 ASA
S070420FR-ASA03Site Visit QCX427 Lafarge SPLC Fr 070420 7 ASA
S070419FR-ASA03Site Visit QCX427 Lafarge SPLC Fr 070419 7 ASA
S070418FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr Da Costa 070418 11:00 0.5 ASA
S070417FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr Da Costa 070417 15:00 0.5 ASA
S070416FR-ASA01Site Visit PLG1292 Rouen Fr 070416 7 ASA
S070330FR-ASA03Site Visit QCX427 Lafarge SPLC Fr 070330 7 ASA
S070329FR-ASA03Site Visit QCX427 Lafarge SPLC Fr 070329 7 ASA
S070328FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 070328 10:00 0.5 ASA
S070323FR-ASA03 QCX427 Lafarge SPLC Fr 070323 0.5 ASA
S070322FR-ASA02 PLG1292 Rouen Fr 070322 1 ASA
S070322FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070322 11:50 0.5 ASA
S070314FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070215 18:00 0 ASA
S070314FR-ASA02 QCX782 Lafarge Le havre Fr 070215 19:00 0.75 ASA
S070313FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070213 16:00 0.5 ASA
S070313FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070313 9:45 0.5 ASA
S070312FR-ASA03Ass-Tel PLG1292 Rouen Fr F. Caron 070312 10:30 1.5 ASA
S070312FR-ASA02Ass-Tel ECS1058 Safi Morocco Aroui 070312 16:00 1 ASA
Onyx / Sonirval
Onyx / Sonirval
Mr Vialle & Caillere
Mr Vialle & Caillere
SNVE-Smedar
M. Delorme
Mr Vialle & Panalytical
Mr Vialle & Panalytical
Mr Vansink Panalytical
SNVE-Smedar
SNVE-Smedar
Cimar (italcementi)
S070312FR-ASA01Adm QCX1254 Holcim Rochefort Fr P. Viverge 070312 14:00 1.5 ASA
S070306FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070306 19:00 0.5 ASA
S070306FR-ASA01e-mail ECS1058 Safi Morocco Aroui 070306 8:45 0.5 ASA
S070305FR-ASA05Develop ECS1058 Safi Morocco 070305 17:00 3 ASA
S070305FR-ASA04Ass-Tel QCX1080 Uniland 070305 16:30 0.5 ASA
S070305FR-ASA03Ass-Tel ECS1058 Safi Morocco Aroui 070305 15:45 0.5 ASA
S070305FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070305 14:10 0.5 ASA
S070305FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr 070305 9:50 0.25 ASA
S070301FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070301 10:45 0.25 ASA
S070228FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070228 13:50 0.5 ASA
S070227FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070227 9:50 0.25 ASA
S070227FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070227 9:50 0.5 ASA
S070226FR-ASA03Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070226 15:50 0.5 ASA
S070226FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070226 13:50 0.25 ASA
S070226FR-ASA01Ass-Tel QCX360 Lafarge PLN Fr G. Garcia 070226 13:45 ASA
S070223FR-ASA01Ass-Tel QCX427 Lafarge SPLC Fr 070223 9:30 1.5 ASA
S070222FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070222 15:00 0.5 ASA
S070222FR-ASA01TC ECS1058 Safi Morocco Aroui 070222 9:00 0.75 ASA
S070221FR-ASA03Ass-Tel QCX1254 Holcim Rochefort Fr Yanick 070221 16:00 0.5 ASA
S070221FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr 070221 11:00 0.5 ASA
Cimar (italcementi)
Cimar (italcementi)
Vallcarca (Spain)
Santi RAYA
Cimar (italcementi)
J.C. Fayolle
Sandrine Legros
Cimar (italcementi)
J.C. Fayolle
S070221FR-ASA01Ass-Tel QCX360 Lafarge PLN Fr G. Garcia 070221 10:00 ASA
S070220FR-ASA03TC QCX782 Lafarge Le havre Fr 070220 19:00 1.5 ASA
S070220FR-ASA02 QCX360 Lafarge PLN Fr 070220 11:00 0.75 ASA
S070220FR-ASA01Ass-Tel QCX360 Lafarge PLN Fr G. Garcia 070220 10:00 0.25 ASA
S070219FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070219 15:00 0 ASA
S070219FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr 070219 11:00 0.5 ASA
S070216FR-ASA03Ass-Tel ECS1058 Safi Morocco Aroui 070216 14:00 0.75 ASA
S070216FR-ASA02TS QCX782 Lafarge Le havre Fr 070216 10:00 1 ASA
S070216FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr 070216 10:00 0.25 ASA
S070215FR-ASA02Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070215 16:00 0.5 ASA
S070215FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr 070215 11:00 0.5 ASA
S070212FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr 070212 15:00 0.25 ASA
S070212FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070212 17:00 0.5 ASA
S070209FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070209 17:15 0.25 ASA
S070209FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070209 14:00 0.5 ASA
S070208FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070208 21:30 0.75 ASA
S070207FR-ASA05Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070207 21:30 1 ASA
S070207FR-ASA04Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070207 20:00 1 ASA
S070207FR-ASA03Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070207 18:15 1 ASA
S070207FR-ASA02Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070207 17:00 1 ASA
S070207FR-ASA01Ass-Tel QCX1254 Holcim Rochefort Fr P. Viverge 070207 15:00 1 ASA
S070206FR-ASA01Ass-Tel QCX360 Lafarge PLN Fr G. Garcia 070206 10:00 0.25 ASA
S070201FR-ASA01Ass-Tel QCX782 Lafarge Le havre Fr P.Legros 070201 17:00 0.25 ASA
J.C. Fayolle
Cimar (italcementi)
J.C. Fayolle
J.C. Fayolle
L. Cassez & I. Dacosta
Support Description
PB for Output on Siemens PLC MILL6 on one server. Solved
Discussion en vue de l'integration d'une DX Bruker et une pastilleuse Hertzog
_ Analyse perle à partir de QCX, puis transfert ver LIMS etc …
PMV 4th & 5th day /5 PMV See Report
PMV 3rd day /5 PMV See Report
Info sur disponibilité drivers pour les surb/Press Herzog envue nvll install
Information concernant l'export des résultats analyse Manu vers LIMS ABB
PMV 1st & 2nd day /5 PMV See Report
Discussion du problème arrivé la veille
Plus d'info concernant Export vers LIMS ds fic XML items déclarés sous eqp Offline pour les items calculés niv sup grpEch
_ Traitement du PB broyeur/Press ech e-mail avec Dam, e-mail lient suggestion de install nv Driver à distance. _ Modif et envoie rapport repception Essai pour facturation
Declenchement d'un Bip Sonore à chaque alarme. Comment l'empêcher. Info Fournie
UAC n'est pas appliqué sur certain operateurs sur un seul serveur. Solution donnée Synchronisation du Serveur (OK)
Discussion with DAM, he does not remember about the Bug Fix, but suggested to contact HM who has treated the PB for other plant. Contact Mr Macdonald, discuss about the PB, there is other pb when modifing the Proportionner config the system is freezing !! .for the request for tablet started from CNV In to the XRF, and avoiding flipper. this is not easy may be we have to change the PLC prg for the conveyor (sensor ?) and robot teatching etc ..., so finaly for the client is not so urgent, the most important is the smpno.
PB and request with QCX, smpno is > 1000000, it dsp ****, it was handeled by coes. Discuss with JAT, it looks that the pb happens some where else, it is not cleaus about Bug fix e-mail to SAAB,
PcAnywhere throug Modem, diagnostic more than 100 A-point with Alg 3, no deadband (c3)? Alot of alrm IO Q buffer full. Show how to modify, re-connection in the afternone alrm disappear. But still event pb. E-mail to HW
Problem with too many commandes to the PLC, and Eventlist. Send e-mail with small manual Howto for A-Point Config with alg3, const 3 and 5
Missed points in exported DB
Faceplates for Micon
Voir Rapport d'intevention
Pb sur la façon d'ouverture de session windows. Info, donnée PB résolu.
PMV See Site report
gestion des problèmes restant coté pfaff, divers contacts et info …
Info pour configuration et envoie valeur C3S (Cru EF) vers la salle de contrôle)
Voir Rapport d'intevention
plusieurs Pb de blocage du système, non traitement de certain échantillon, cartouche reste dans la station etc. .. Après un reboot un éch. est traité, le 2eme reste dans la station sans traitement. Débouchage Manu, et renvoie, nettoyage de la station et du capteur présence cartouche. PB résolu.
Par moment BLX ne calcule pas les consignes. Ceci est dû au prélèvement effectué avant l'analyse du précédent
Suite au changement des adresses IP, Pb au niveau d'un poste client. Resolution OK
Suite au changement des adresses IP, Pb au niveau de interlock entre le robot et le TTR. L'adresse référence du TTR dans l'API n'a pas été modifié.
Certain résultats Dx ne sont pas transférés vers QIMS. L'export n'était pas configuré. Configuration et test OK
3- pb pastilleuse2 See Report Pb resolu
3- pb pastilleuse2 diagnostic, test et mise en place d'une solution,
1- DecServer config et test 2- Ndivers creation points et config pour export vers protop 3- pb pastilleuse2 diagnostic
1- DecServer config et test 2- Ndivers creation points et config pour export vers protop 3- pb pastilleuse2 diagnostic
discussion et envoie de documents pour effectuer des backups images sur disque et cassettes.
Problème avec le panel. Traitement contact Pfaff pour l'envoie d'un nouveau panel. Panel arrivé à l'usine en fin de semaine
Problème avec le panel de la station d'emission cru EF. Le pannel est HS. Divers contacts pour regler le PB, CCD etc…
Impossible de faire fonctionner les applications QCX sur le poste client. Le Poste est en mode maintenance. Redémmarage du poste en mode marche. OK
Perte de communication avec la FX, passtille arrive à l'extremité du convoyeur mais l'analyse ne demarre pas. Le probleme se situe au niveau de l'UAI. Après redemarrage du PC et de l'application SuperQ le problème est résolu
Suite à un Pb de collusion entre Robot et le TTR la pince, dereglage de présence godet. Info forunie.
Comment envoyer les résultats d'analyse au système de CC
3.5 jours durant la visite une intervention uregente à Vallcarca en Espagne
Pb de copie d'un resultat vers Apoint. L'association n'était pas effectuée.
PMV on ECS VMS system + PLG PB solving
PLG Installation of ECS7.7 & PLG7.5 + pb solving
Visite annulelle dans le cadre du contrat de maintenance
Le PB de l'insitec reste pour une partie des recettes auto (ciment instantanné)
Investigation pour pb affichage etat Malvern sur les synoptiques
How to associate Insitec results to Acx Items. Answer given to the client.
Various PB Solving & info
Pb, since Friday night the XRF in error. There was no possibility for the client to bring it to Ready. E-mail recieved with some trace, showing that superQ answer the Open Lisit request by status=fatal. After investigation batch QCX_LIST uncoverable problem in superQ. after creation of a new batch QCX_LIST1, list status is OK
BLX la valeur C3S affiché sur le synop. Est differente de celle analysée. Le pb est dû a une mauvaise association dans "Export points"
Les analyses sur FX ne sont pas executé. L'échantillon arrive au bout du convoyeur, l'analyse ne démarre pas. Le PB était au niveau du port échatillon qui n'était logiquement pas defini (cup 37) au niveau de superQ
Questions conernant la liaison avec XRF suite crash du disque du PC SuperQ, et la ré-installation.
new feeder connected on Mill 3 & Mill 4. setpoint is 0 for this new feeder on mill 4 only. Investigation and test etcc . Pb solved.
Pb au niveau de la station de reception, le dosage ne démarre pas. Après deblocage de la station remise ne état le pB persiste. Après re-boot OK.
Suite des Investigations pour pb affichage etat Malvern sur les synoptiques pas de résultat
after a PB not related to QCX, one of SGP editing has been locked. Check if it is not locked by another terminal.
check for the Insitec Problem. When removing output eqp. The recipe is working. Now it has to be test in automatic to confirm.
after some modification done the sample is transported to the Insitec but the analysis do not start. Diagnostic, demand to send HC and trance. From the trace we see Output eqp is defined. E-mail to try without Outout eqp.
Problem with the Malvern, Eqp looks OK but all samples go the the Buffer rack. Divers diagnostic, finaly the eqp was in passif mode. Still in the mimic's after stopping and starting the malvern driver the status in the mimic' is "Driver Stopped" even though the driver is working OK. People in the plant will call back thursday to make a diagnostic.
1- Question on the possibility to remove "backgound test" in the insitec. No it is
not possible, this demands Driver modification ask HOeB. 2- How to start dedusting during powering material by the robot in Mill & Press and not after (chack this with CCD)
diagnotic on Comm pb. Solving alarm printer pb, Modif Rep, Log Horizon …
diagnostic with alarme printer
QCX Implementation of Error Handeling for Cubix
Info how to implement new calibrated program on XRD.
Operator samples do not start, from T-Input. Reset Eqp
PLG Hotfixes installation & test + Report correction
Discussion with PHL about the site visite next week , and the solution …
call for confirmation about QIMS . Not checked yet
demande d'info,& discussion. We will find a solution even if we have to change tis driver
QIMS Pb transfert of valproc results before Pntacq, then the results can not be stored by PCC
Some results are not transfered to CCR. Problem is when sample (for a specific SG) is taken before last sample analyzed, result will not be transfered
1- Test Error Handeling, 2- Old Bug correction on the cubix Dirver Sample
accepted even if Analysis failed. 3-AUS use one SGP for several source
sampling on Raw Mill. 4- Backup to the Spare Disk.
1- Check with Mr Vialle the Error list sent by Panalytical, to select the relevent for QCX error handeling. 2- New menu for Invalid Raw sample, just go to Clean
UAI Interface for Cubix had some problems. Panalystical Instaalled new UAI, which also handle errors as number.new UAI has been tested OK, improbvement for file trasfert for Rietveld (modification in FLSA side delay befor transfering file)
Some sample are not sampled automaticaly. The problem is one of sending station is stopped. PS Cut, so the PLC is spending too much time trying to get info from there, then the command take sample (keep 1 some seconds and back to 0) is not seen by the PLC. suggest to PS On that station
Several phone call and discussion for common visite to site to solve alarm reporting from cubix to QCX
Problem ON Dosing and AUS, sample is sent back to the sending station, and returned immediately back to the Lab !!!, the client has made some modification on the PLC prg. !! It must be this modification who cause the Problem
Test on Laptop for modification Sampling Time is OK. Transfert through XML has to be checked on the client system.
Questions on Transfert on QIMS. The Possibility to change Sampling Time. Information Given, But we have to check if it works and trasfert will be done through XML files
Problem on Balance status intermedite even if we reset …investigation suggest Reset all RCV POS.
contact the client and discuss the situation. E-mail to confirm our intervention W13 and then w19 for new version of PLG. E-mail to KIK …
the client tried the solution sent at march 06, it worked for Apoints but the file crush when processing Bpoint. I have to restore client DB and check.
E-mail the solution for Operator action. To the client with Explanation HowTo
Unlock Robolab, XRF Stat Problem.
Info on how to transfer Alarms to from QCX to WinCC (Client Control system)
VPN client config, and VNC install to connect remotely to the site. No success, access denied. The client at the plant will investicate with it's IT;
QIMS Pb, some of XRF Items are not reported any more to UNILAB. After cheking XML file Info from QCX are correct, but as chanal names have been changed by the Client from SuperQ, the references to these new names have not been linked to UNILAB ones. solution in client side
Operator action Problem.Develop, and test of Macro VB to change all relevent Events type to "Log Event, do not announce"
Operator action Problem. PHL Confirm that we must change the Log Events on all points to 1. Call to the client to tell we are going to send a small VB program to change the necessary.
1- Client has created Bpoints to make ON/Off portion for some Eqp in the automatic samples. It does not work. The problem wes in the Button references in OPS. 2- Robot supply cup 2 times to the Balance then Collusion. Suggest temporary solution, in the robot program, put a waiting time (4 sec) in the Procedure PUT BAL CUPSML
Buffer Rack physicaly empty but, it looks as it is seen as occupied by robolab, lock situation. After resetting all position it is OK. We have to check the driver, some positions may be not released by robolab ?
new Recipe made is stopped after the Mill ? The configuration was with accept/manual. Info about sample staying in the XRD Rack.
the doses for 2nd and 3rd Cup has got less material than the first, the dosing is then rejected. Idiscussion about that, and how to increase the # of doses.
Finaly the client solve the networking problem and get connected to the Malvern. The Sub-sample for Malvern is not created. The reason is the signal is Off (Bpoint) signaling we want (or not) a Malvern Portion.
Malvern comm is OK but unable to start any recipe to Malvern. Several investigation. Check if from automatic samples is OK. Finaly success. Info on how to set number of doses
Client manage to Ping succefully, but still no comm with Malvern PC. Still we have network PB. We are not able to access any directory, etc .. Client will check with its IT
The Malvern was not used for more than 1 month. The client have some trouble to make it working. No net access any more to the Malvern PC (no answer to Ping)
xrd Pb. Is solved by rebooting the XRD PC. Info if it is possible to get Kilocounts from XRF results.
problems on transfer new Sgp to QIMS. Conf reports packages for transfer to QIMS
Again info on alarm transfert, and one of the feeder rate are transfered on Kg/h, Info given on how to to get them on t/h
Operator action PB. Client Checked the conf. It is OK. He sent also the Prodb files. Contact PHL to see the possibility of handling the PB by FLSA-H throug him as he is French speaking. PHL find that more than 1600 operator actions are in the event file. Call and Send e-mail to the client telling that PHL will contact them ...
Info on modification of the Mills and Press PLCs from S5 to S7, questions about Formulas.
Discussion on the QIMS Problem.
Informations and trouble shouting on formulas and export Results
Informations and trouble shouting on formulas and export Results
Information on QIMS
Trouble shouting Robolab + Info
Trouble shouting Robolab + Info
Trouble shouting Robolab + Info
Trouble shouting Robolab + Info
Trouble shouting Robolab + Info
Trouble shouting Robolab + Info
Info on Robolab menu
Information on Active Samples
xrd Pb. Sensor checked PB persiste. It may be time out pb. In the exchange between QCX Driver and the eqp. As comm goes throuh files, Reboot the XRD PC and see if not Deeper investigation needed. It may be necessary to move to site.
Modification of PntACQ Driver according to DaM indication. Compilation and test . The modified driver is sent by e-mail to the client
Time evaluation of driver modification (VMS) for a new Malvern Eqp. Check of Malvern specification and the existing driver
Some of XRD starts but just (sec before) the Eqp is delared in Fault by QCX. Even though the analysis finish correcltely. Suggest to check the sensor.
Informations on complex formula. Screen HC of some examples made and sent by e-mail.
Some of Operator actions are not reported in event system.This has been treated by one of our colleague in Nov2006 but forgten by him !. Call PHL for support, he suggests to check system config. Screen HC of the Conf to check made and sent by e-mail to the client
Reproducing PntACQ proplem on system on Laptop , Bug report and call to DaM. Temporary solution may be made in the PntACQ Driver. The client is informed by e-mail that problem is under treatement solution will be found soon
Information and diagnostic on with PntACQ Driver Program name not registerd so it causes Pb to export to QIMS
C3A & IS are not calculated correctely. Formula of C3A is correct but the item was not associated to the correct formula. IS we did not find the reason (IS not solved yet)
Robot fail to take some samples on the XRD conveyor. Solution Conveyor has to be fixed correctely and/or Re-teach Robot position
AUS Sample Taken sent to Lab but not registerd and not treated by QCX. Signal Sample taken not sent at time to QCX then Timeout. Solution (Increase timeout from 45s to 240s)
Support_ID Client Date Hour
S070207FR-ASA04 Ass-Tel QCX1254Holcim 070207 20:00 1 ASA Night
S070207FR-ASA05 Ass-Tel QCX1254Holcim 070207 21:30 1 ASA Night
S070208FR-ASA01 Ass-Tel QCX1254Holcim 070208 21:30 0.75 ASA Night
S070516FR-ASA06 Ass-Tel QCX782 Lafarge Le havre Fr 070516 20:10 1.5 ASA Night
S070809FR-ASA01 Ass-Tel QCX1254Holcim 070809 11:35 0.5 ASA Holida
S070810FR-ASA01 Ass-Tel QCX1254Holcim 070810 9:20 0.5 ASA Holida
S070822FR-ASA01 Ass-Tel QCX1254Holcim 070822 9:30 0.5 ASA Holida
S071023FR-ASA01 Ass-Tel QCX782 Lafarge Le havre Fr Legros 071023 20:00 1.5 ASA Night
S071125FR-ASA01 Ass-Tel ECS1058 Aroui 071125 14H 0.5 ASA Holida
Support type
System
Site / Country
Client Pers
T. Spent (H)
FLSA eng
Time/type
Rochefort Fr
P. Viverge
Rochefort Fr
P. Viverge
Rochefort Fr
P. Viverge
LeGros et Michelo
Rochefort Fr
P. Viverge
Rochefort Fr
P. Viverge
Rochefort Fr
P. Viverge
Cimar (italcementi)
Safi Morocco
Support Description
Trouble shouting Robolab + Info
Trouble shouting Robolab + Info
Trouble shouting Robolab + Info
Suite à un Pb de collusion entre Robot et le TTR la pince, dereglage de présence godet. Info forunie.
Info pour configuration et envoie valeur C3S (Cru EF) vers la salle de contrôle)
Pb au niveau de la station de reception, le dosage ne démarre pas. Après deblocage de la station remise ne état le pB persiste. Après re-boot OK.
Perte de communication avec la FX, passtille arrive à l'extremité du convoyeur mais l'analyse ne demarre pas. Le probleme se situe au niveau de l'UAI. Après redemarrage du PC et de l'application SuperQ le problème est résolu
plusieurs Pb de blocage du système, non traitement de certain échantillon, cartouche reste dans la station etc. .. Après un reboot un éch. est traité, le 2eme reste dans la station sans traitement. Débouchage Manu, et renvoie, nettoyage de la station et du capteur présence cartouche. PB résolu.
UAC n'est pas appliqué sur certain operateurs sur un seul serveur. Solution donnée Synchronisation du Serveur (OK)
S080724FR-ASA Ass-tel QCX354 Lafarge Contes Fr G. Camous 080724
S080722FR-ASA Site Visit QCX354 Lafarge Contes Fr G. Camous 080722
S080715FR-ASA Site Visit QCX782 Lafarge Le havre Fr P.Legros 080715
S080713FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080713 Sunda
S080711FR-ASA Remote conn/ QCX354 Lafarge Contes Fr G. Camous 080711
S080702FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080702
S080623FR-ASA Site Visit QCX427 Lafarge SPLC Fr 080623Landais/ Caillière
S080606FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080606
S080605FR-ASA Site Visit QCX427 Lafarge SPLC Fr 080605
Landais/ Sandrine Legros
S080604FR-ASA Ass-Tel QCX427 Lafarge SPLC Fr 080604
S080408FR-ASA Ass-Tel QCX427 Lafarge SPLC Fr Eric Landais 080408
S080321FR-ASA Remote conn QCX782 Lafarge Le havre Fr 080321
S080319FR-ASA Site Visit QCX782 Lafarge Le havre Fr 080319
Sandrine Legros
FAYOLLE/Toupin
FAYOLLE/Toupin
S080317FR-ASA Site Visit QCX427 Lafarge SPLC Fr Choupay 080317
S080305FR-ASA Site Visit QCX427 Lafarge SPLC Fr Landais 080305
S080303FR-ASA01 QCX782 Lafarge Le havre Fr FAYOLLE 080303
S080227FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080227
S080212FR-ASA Site Visit QCX427 Lafarge SPLC Fr 080212Choupay/Landais
S080201FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr P. Legros 080201
S080124FR-ASA Site Visit QCX427 Lafarge SPLC Fr Mr Landais 080124
S080117FR-ASA e-mail QCX782 Lafarge Le havre Fr FAYOLLE 080117
S080117FR-ASA Ass-Tel QCX427 Lafarge SPLC Fr 080117
S080116FR-ASA Ass-Tel QCX427 Lafarge SPLC Fr Mr Landais 080116
S080116FR-ASA e-mail QCX782 Lafarge Le havre Fr FAYOLLE 080116
S080109FR-ASA Ass-Tel QCX360 Lafarge PLN Fr G. Garcia 080109
S080107FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080104
Mme Choupay
S080107FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080104
S080104FR-ASA Ass-Tel QCX782 Lafarge Le havre Fr FAYOLLE 080104
10h&15h&16h 1 ASA
11 ASA
12 ASA
14H00&20H 2.5 ASA
7 ASA
18H00 0.5 ASA
8 ASA
diagnostic et info pour
résoudre 1- pb transmission Pfmanu à
Unilab. 2- Remplacement lecteur Cassette
Résolution PB Drivers FX
diagnostic pour le problème Robot survenu le wwek-end. Finalement c'était un PB de mauvaise sycronisation.
Troubleshooting of the Robot Problem
Troubleshooting of the XRF new driver
Info, Clincker result has not been transmited to CCR. The reason is a sample have been taken befor last clinker sample analyzed
Test to repreduce problem happening June 4. usage of 4 portion per sample. In the begining of the afternoon the PB happened. DB put back, recommendation to a avoid 4 portions use
19H00 0.5 ASA
8 ASA
The operators says that some time when changing sample taking frequency it is not respected by the system. Explanation may be for a given sample we have to change the frequency for all sample group (product) of the sampler and not anly the current one.Solving Predosing PB. the PB has become serious yesterday aftrnoon. the plant decided to use the image disk made one month ago. This worked OK. so my work was to investigate what happened yesterday. we put the suspected disk on disconnected spare machine. after long investigation 1- we suspect the uses of 4 portions in the predoses it is the maximun autorized by robolab. it has never used befor, it is similar to a problem with no of machines per menu. Solution : 2- we put back the disk but with the DB savedat.vma from one month ago, OK. 3- the samples (72) made during last 24 hours were rejected by QIMS (the have
11h et 14h 0.5 ASA
9h:15 1 ASA
10h:30 0.5 ASA
7 ASA
Dosing/deviding PB on the predoser. Since the morining one predose machine, does not dose some or all the portion. Check of the comM, events etc.. After reboot the PB remain. Urgent intervention the to do the following day.
PB en Result transfer to QIMS on some of SGP. This was due to changes on XRF1 and XRF2 for (tablet and bead). Explanation on where to change config.
Test of the remote connection Through the secure server in Copenhagen, using BOMGAR
1- Discussion on spec for Feeder acsh Estimation, based on complicated calculation. 2- Discussion on how to improve the diagnostic when pb in the Recv Station 3- B-Points for Eqp availability as part of new performance reports
7 ASA
7 ASA
10h:00 ASA
16h:20 0.5 ASA
7 ASA
Work with panalitical reducing analysis time, espcialy sampling handle in the changer
Transfert PB between XRD Sgp Data and Protop. Solved
JCF suggests a meeting in site to discuss the complecated calculation. We agree for 19/3/08 in the morning
Discussion on problem happend on RCV & Balance and TTR. What is the possibility to intreuce more info in the OPS RCV etc to help for diagnostic. Also disscussion on some complicated calculation needed in the plant, the possibility of making a specific application.
XRD Driver Modification to get both results from Pic & Rietveld simulanousely. Also Work on Data export to Protop
16h:20 0.5 ASA
7 ASA
18:15 0.5 ASA
0 ASA
0 ASA
19:00 1 ASA
10:30 0.5 ASA
21:45 0 ASA
TTR shows status not updated. Check Modicon TTR PLC, No comm. Ping to TTR IP Adress OK. Check visualy the PLC looks OK. After swich off and on the TTR, Comm back OK
Check and test new spare QCX Server
study the possibility to make some specific complicated calculation with QCX
coordination for XRF replacement. Info for normal (not Reiveld) FCaO on the XRD
Discussion for how to build a spare VMS QCX Server. Plan intervention in site to help on this January 24
e-mail answer/diagnostic about PB of 07/01/08. See Report PB_Lehavre_080107_diagnostic_email_a_JCF.doc
Infor about prg nbr for the Malvern, the client changed the Eqp to Insitec
Call back for confirmation system is OK
18:00 2 ASA
11:00 0.5 ASA90.5
Robolab : Big cup is not moved to the rack, this lock the recipe in the Recv Station. Stopping the BC driver freeze Eqp Tools. Reboot did not help, sample stays in RCV,not treated. Err PM, (we find PM service stopped), clean non finished recipe reboot again, OK
Info pour des calculs compliqué (Solveur)