SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit...

8
Job Name: System Reference: Date: Indoor Unit: PLA-A18EA7 Outdoor Unit: PUY-A18NKA7 PUY-A18NKA7-BS INDOOR UNIT FEATURES Space-efficient ductless installation Equipped with 3D i-see Sensor TM for enhanced comfort and energy efficiency Airflow settings for high and low ceiling applications Individual vane settings for direct/indirect airflow control or variable airflow patterns Knockouts for outside-air intake and branch-duct run Filter indicator signal Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement) Built-in condensate lift mechanism Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more OUTDOOR UNIT FEATURES Variable speed INVERTER-driven compressor Power receiver pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) Low ambient cooling down to -40ºF providing 100% capacity (only for PUY models with wind baffles installed) 24-hour continuous operation (cooling mode) High pressure protection Fast restarts in cooling mode (15 seconds for 12/18/36/42; 50 seconds for 24/30) Superior energy and operational efficiency SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) 18,000 BTU/H CEILING-CASSETTE AIR-CONDITIONING SYSTEM Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. P-SERIES

Transcript of SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit...

Page 1: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

Job Name:

System Reference: Date:

Indoor Unit:PLA-A18EA7

Outdoor Unit:□ PUY-A18NKA7□ PUY-A18NKA7-BS

INDOOR UNIT FEATURES• Space-efficient ductless installation • Equipped with 3D i-see SensorTM for enhanced comfort and energy efficiency• Airflow settings for high and low ceiling applications• Individual vane settings for direct/indirect airflow control or variable airflow patterns• Knockouts for outside-air intake and branch-duct run• Filter indicator signal• Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement)• Built-in condensate lift mechanism• Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more

OUTDOOR UNIT FEATURES• Variable speed INVERTER-driven compressor• Power receiver pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30)• Low ambient cooling down to -40ºF providing 100% capacity (only for PUY models with wind baffles installed)• 24-hour continuous operation (cooling mode)• High pressure protection• Fast restarts in cooling mode (15 seconds for 12/18/36/42; 50 seconds for 24/30)• Superior energy and operational efficiency

SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS)18,000 BTU/H CEILING-CASSETTE AIR-CONDITIONING SYSTEM

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

P-SERIES

Page 2: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

Model Number

Indoor Unit PLA-A18EA7

Outdoor UnitPUY-A18NKA7

PUY-A18NKA7-BS

Cooling1

Maximum Capacity Btu/h 18,000

Rated Capacity Btu/h 18,000

Minimum Capacity Btu/h 8,000

Maximum Power Input W 1,250

Rated Power Input W 1,250

Moisture Removal Pints/h 2.4

Sensible Heat Factor 0.85

Power Factor % 95.3

Efficiency

SEER 24.6

EER1 14.4

ENERGY STAR® Certified (ENERGY STAR products are third-party certified byan EPA-recognized Certification Body)

Yes

Electrical

Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz

Guaranteed Voltage Range V AC 198 – 253

Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230

Voltage: Indoor - Outdoor, S2-S3 V DC 24

Voltage: Indoor - Remote controller V DC 12

Recommended Fuse/Breaker Size A 15

Recommended Wire Size (Indoor - Outdoor) AWG 14

Indoor Unit

MCA A 1.00

Fan Motor Full Load Amperage A 0.36

Fan Motor Output W 50

Airflow Rate, Dry CFM 420-460-570-600

Airflow Rate, Wet CFM 380-420-530-560

External Static Pressure in.WG n/a

Sound Pressure Level dB(A) 28-29-31-32

Drain Pipe Size In. (mm) 1-1/4 (32)

Condensate Lift Mechanism, Max. Distance In. 33-7/16

Heat Exchanger Type Plate fin coil

External Finish Color White Munsell 6.4Y 8.9/0.4

Unit Dimensions // Grille Dimensions

W: In. (mm) 33-1/16 (840) // 37-13/32 (950)

D: In. (mm) 33-1/16 (840) // 37-13/32 (950)

H: In. (mm) 10-5/32 (258) // 1-9/16 (40)

Package Dimensions // Grille Dimensions

W: In. (mm) 35-9/16 // 39-6/16

D: In. (mm) 34-5/16 // 38-3/16

H: In. (mm) 15 // 4-12/16

Unit Weight // Grille Weight Lbs. (kg) 46 (21) // 11 (5)

Package Weight Lbs. (kg) 68 (31)

SPECIFICATIONS: PLA-A18EA7 & PUY-A18NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 3: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

Model Number

Indoor Unit PLA-A18EA7

Outdoor UnitPUY-A18NKA7

PUY-A18NKA7-BS

Indoor Unit OperatingTemperature Range

Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB

Outdoor Unit

MCA A 11

MOCP A 28

Fan Motor Full Load Amperage A 0.50

Fan Motor Output W 46

Airflow Rate CFM 1,590

Refrigerant Control Electronic Expansion Valve

Heat Exchanger Type Cross fin

Sound Pressure Level, Cooling1 dB(A) 44

Compressor Type INVERTER-driven twin rotary

Compressor Model SNB130FNCM2

Compressor Rated Load Amps A 7

Compressor Locked Rotor Amps A 12

Compressor Oil Type // Charge oz. FV50S // 16

External Finish Color Ivory Munsell 3Y 7.8/1.1

Base Pan Heater n/a

Unit Dimensions

W: In. (mm) 31-13/16 + 7/16 (809+62)

D: In. (mm) 11-3/16 (300)

H: In. (mm) 24-13/16 (630)

Package Dimensions

W: In. (mm) 37-1/16

D: In. (mm) 16-3/16

H: In. (mm) 27-7/16

Unit Weight Lbs. (kg) 99 (44)

Package Weight Lbs. (kg) 110 (50)

Outdoor Unit OperatingTemperature Range

Cooling Intake Air Temp (Maximum / Minimum) °F 115 DB / -40* DB

RefrigerantType R410A

Charge Lbs, oz 4 lbs, 14 oz

Piping

Gas Pipe Size O.D. (Flared) In.(mm) 1/2 (12.7)

Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35)

Maximum Piping Length Ft. (m) 165 (50)

Maximum Height Difference Ft. (m) 100 (30)

Maximum Number of Bends 15

SPECIFICATIONS: PLA-A18EA7 & PUY-A18NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 4: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

Notes

AHRI Rated Conditions (Rated data isdetermined at a fixed compressorspeed)

1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB

*Wind baffles required to operate below 23F DB in cooling mode. For PUY models, wind baffles can be utilized to extend the cooling operation range to-40F. Please refer to the wind baffle submittals to determine which baffles are required to meet the desired operation range.**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION• External Outer Panel: Phosphate coating + Acrylic-Enamel coating• Fan Motor Support: Epoxy resin coating (at edge face)• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.

SPECIFICATIONS: PLA-A18EA7 & PUY-A18NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 5: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

High-efficiency Filter Element □ PAC-SH59KF-E

Wireless Remote Controller □ PAR-FL32MA-E

Wireless Remote Receiver □ PAR-FA32MA-E

Signal Receiver □ PAR-SR3LA-E

Backlit, Wall-mounted, Wireless Controller □ MHK1

Portable Central Controller □ MCCH1

Wired MA Controller □ PAR-33MAA

Simple MA Controller □ PAC-YT53CRAU

Touch MA Controller □ PAR-CT01MAU-SB

Wired Remote Sensor □ PAC-SE41TS-E

Lockdown Bracket for Wireless, Hand-held, Remote Controller □ RCMKP1CB

Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1

Outside Air Sensor for MHK1 □ MOS1

Flush Mount Remote Temperature Sensor □ PAC-USSEN001-FM-1

Wireless Interface □ PAC-USWHS002-WF-1

Thermostat Interface □ PAC-US444CN-1

kumo station® □ PAC-WHS01HC-E

USNAP Interface □ PAC-WHS01UP-E

IT Extender □ PAC-WHS01IE-E

BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1

External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3

Connector for CN32 (remote on/off) □ PAC-SE55RA-E

Remote Operation Adapter (with wire terminals for remote ON/OFF and operation status/ error)1 □ PAC-SF40RM-E

Grille (required) □ PLP-40EAEU

Multi-Function Casement □ PAC-SJ41TM-E

Installation/Trim Panels □ PLFY-ITP1

Space Panel □ PAC-SJ38AS-E

Air Outlet Shutter Plate □ PAC-SJ37SP-E

Blue Diamond Sensor Extension Cable—15 Ft. □ C13-103

MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V

MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) up to 48,000 Btu/h[recommended]

□ X87-721 - 208/230V

Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) □ DPLS2

3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - Black □ TAZ-MS303

3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - White □ TAZ-MS303W1 Unable to use with wireless remote controller

ACCESSORIES: PLA-A18EA7

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 6: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

Air Outlet Guide □ PAC-SJ07SG-E

Front Wind Baffle □ WB-PA4

Side Advanced Wind Baffle □ WB-SD4

Rear Advanced Wind Baffle □ WB-RE4

Drain Socket □ PAC-SJ08DS-E

Centralized Drain Pan □ PAC-SG63DP-E

M-NET Converter □ PAC-SJ19MA-E

M-NET Converter □ PAC-SJ96MA-E

Control/Service Tool □ PAC-SK52ST

Hail Guard □ HG-A5

Condensing Unit Mounting Pad 16" x 36" x 3" □ ULTRILITE1

Outdoor Unit Stand—12" High □ QSMS1201M

Outdoor Unit Stand—18" High □ QSMS1801M

Outdoor Unit Stand—24" High □ QSMS2401M

Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel □ QSWB2000M-1

Heavy Duty Wall Mounting Bracket for Outdoor Units—316 Series Stainless Steel □ QSWBSS

1/4" x 1/2" x 15' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-15

1/4" x 1/2" x 30' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-30

1/4" x 1/2" x 50' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-50

1/4" x 1/2" x 65' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-65

1/4" x 1/2" x 100' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-100

ACCESSORIES: PUY-A18NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 7: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

PLA-A18EA7

6O

UTLIN

ES AN

D D

IMEN

SION

S

12(305)OR MORE

177-3/16(4500)OR LESS

FE

REFRIGERANT PIPEΦ6.35FLARED CONNECTION 1/4F

REFRIGERANT PIPE{12.7FLARED CONNECTION 1/2F

REFRIGERANT PIPEΦ9.52FLARED CONNECTION 3/8F

REFRIGERANT PIPE{15.88FLARED CONNECTION 5/8F

A B

9-1/2(241)

11-1/16 (281)

11-3/4 (298)

10-3/16 (258) 3(76)

3-1/8(79.5)

C

3(76.5)

DMODELS

PLA-A.EA7*:12/18/24/30/36/42

137-13/16(3500)OR LESS

10-7/16(265)OR MORE

WALL

CEILI

NG H

EIGH

TSP

ACE

IN TH

E C

EILIN

G

GRILLE 70-7/8(1800mm) OR MORE FROM FLOOR

INDOOR UNITINDOOR UNIT

FLOOR

BETWEEN INDOOR UNIT

OBSTACLECEILING

OR MORE118-1/8(3000mm)

59-1/16(1500mm) OR MORE

39-3/

8 OR

MORE

(1000

mm)

1/4OR

MOR

E(7m

m)

EF

BETWEEN THE TOP OF UNITAND CEILING SLAB

CEILING

{3-15/16({100)CUTOUT HOLE

{4-15/16({125) BURRING HOLE PITCH SELF-TAP 4 SCREWS:3 PLACES

DETAILS OF FRESH AIR INTAKE HOLE

6-1/

4(1

58)

120°

120°

21

MAIN UNITSUSPENSION BOLTM10 OR W3/8

INDOOR UNIT/OUTDOOR UNITCONNECTING WIRE,POWER SUPPLY WIRE ENTRY

GRILLE

DRAIN PIPEVP-25 CONNECTION(CONNECTED THE ATTACEDDRAIN SOCKET)

CEILING

SUSPENSION BOLTLOWER EDGE

THE BOTTOM OF I-SEE SENSOR (17

)+5 0 0+3/16

2-5/

16(5

8)1-

15/1

6 TO

2-3

/4(5

0-70

)5-

1/2

(140

)6-

11/1

6(1

70)

4-1/

8(1

05)

7-1/

2(1

90)

11/1

6A

1-9/

16(4

0)B

2-3/8(60)

24-3/4(628)

GRILLE

CEILING

{6-7/8({175) BURRING HOLE PITCHSELF-TAP 4 SCREWS:4 PLACES(CONNECTING TO BRANCH DUCT)

{5-7/8({150) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)

SELF-TAP 4 SCREWS:14 PLACES(CONNECTING TO BRANCH DUCT)

13-3/4×3-15/16(350×100) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)

6-9/16(167)

6-1/8(155)

15-3

/8(3

90) 3-

9/16

(90)

3-15

/16

(100

)3-

15/1

6(1

00)

3-9/

16(9

0)

13-3

/4(3

50)

5-1/8(130)

3-15/16(100)

70°

BRANCH DUCT HOLE

(CEILING HOLE)

(SUSPENSION BOLT PITCH)

(SUS

PENS

ION

BOLT

PITC

H)

(CEI

LING

HOLE

)

FRESH AIR INTAKE HOLE

BRANCH DUCT HOLE

REMOTE CONTROLLER WIRE ENTRY

INDOOR UNIT/OUTDOOR UNITCONNECTINGTERMINAL BLOCK BRANCH DUCT

HOLE

+40 0

0+1-9/

16(66

0 )

REMOTECONTROLLERTERMINAL BLOCK

BRANCH DUCT HOLE

13/1

6 TO

1-3

/4(2

0-45

)33

-7/8

TO

35-

13/1

6(86

0-91

0)

13/1

6(2

0)26

13/1

6 TO

1-3

/4(2

0-45

)

13/16 TO 1-3/4(20-45)

13/16 TO 1-3/4(20-45)

31-5/16 (795)33-7/8 TO 35-13/16(860-910)

33-1/16(840)

33-1

/16(

840)

5-11

/16

(145

)

5-11/16(145)

1/4(

6)5-11/16(145)

5-11

/16(

145)

13/1

6(2

0)

8-3/4(222)

7-5/8(193)

3-1/

8(79

.5)

5-1/

4(1

33)

D C

REMOTE CONTROLLER WIRE ENTRY

GRILLE

{5-7/8({150) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)

{6-7/8({175) BURRING HOLE PITCHSELF-TAP 4 SCREWS:4 PLACES(CONNECTING TO BRANCH DUCT)

CEILING

17-1

1/16

(450

)

70°

COMPANY NAME

I-SEE SENSOR CORNER PANELSOME GRILLES DO NOT HAVE THIS PART.*CAN INSTALL TO THE CORNER EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER)

AIR INTAKE GRILLE

CORNER POCKET

DRAIN HOLE

AUTO VANE

(AIR OUTLET HOLE)

(AIR

OUT

LET H

OLE)

(AIR

INTA

KE H

OLE)

(AIR INTAKE HOLE)

OPTIONAL PART:SIGNAL RECEIVER

20-7

/8(5

30)

20-7/8(530)

37-3/8(950)

37-3

/8(9

50)

20(508)

20(5

08)

3-1/2(89)

1-7/16(37)

3-1/

2(8

9)1-

7/16

(37)

DEFROST/STAND BY LAMPOPERATION LAMPRECEIVER

EMERGENCY OPERATION SWITCH <HEATING>AND EMERGENCY UP/DOWN SWITCH<DOWN>

EMERGENCY OPERATION SWITCH <COOLING>AND EMERGENCY UP/DOWN SWITCH<UP>

DETAILS OF SIGNAL RECEVER

VANE MOTOR

NOTE1.CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES.2.REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.3.FOR THE SUSPENSION BOLT, USE M10 OR W3/8.

(PROCURED AT THE LOCAL SITE.)4.FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4''({32) PVC TUBE).DRAIN PUMP INCLUSION.

RAISE IS MAX 33-7/16''(850mm) FROM THE CEILING.5.ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE.MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR

CONTROL/POWER WIRES CONNECTION.6.THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED

WITH THE GRILLE ATTACHED.7.REQUIRES "E" OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION.8.WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY.

OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR.(IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)

9.AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.

10.FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER ORMULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING.

Unit: inch (mm)

DIMENSIONS: PLA-A18EA7 & PUY-A18NKA7 (-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 8: SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS) · Model Number Indoor Unit PLA-A18EA7 Outdoor Unit PUY-A18NKA7 PUY-A18NKA7-BS Indoor Unit Operating Temperature Range Cooling Intake

PUY-A18NKA7(-BS)

14

PUZ-A12NKA7 PUZ-A18NKA7 PUY-A12NKA7 PUY-A18NKA7PUZ-A12NKA7-BS PUZ-A18NKA7-BS PUY-A12NKA7-BS PUY-A18NKA7-BS

6 OUTLINES AND DIMENSIONS

1/2 conduit hole

144<5-21/32>

2-{22.2<7/8>

22<7/8>

38<1

-1/2

>24

1<9-

1/2>

Min.100mm<3-15/16>

Piping and wiring connection canbe made from the rear direction only.

*1 In the place where short cycle tends to occur, cooling and heating capacity and power consumption might get lowered 10%. Air outlet guide (optional PAC-SG58SG-E) will help them improve. *2 If air discharges to the wall, the surface might get stained.

2 sides should be open inthe right, left and rear side.

Min.100mm<3-15/16> as long as no obstacle is placed on therear and light-and-left sidesof the unit

*1*2 *1

Air intake

Air discharge4-oval hole

Air intake

Service panel

Connection for liquid pipe

Service panel for charge plug

Service port

Connection for gas pipe

Min.100mm<3-15/16>

Min.500mm<19-11/16>

Min.350mm<13-25/32>

Basi

cally

open

Max

.

<Foundation bolt height>

FOUNDATION

Please secure the unit firmlywith 4 foundation M10<W3/8> bolts.(Bolts, washers and nut must be purchased locally.)

18m

m<2

3/32

>

{33<1-5/16> drain hole

43.6

<1-2

3/32

>15

2<6>

155

400<15-25/32>

347.5<13-11/16>

45.4<1-25/32>

365<

14-3

/8>

330<

13>

300<

11-1

3/16

>

40<1-9/16>

Handle

600<

23-5

/8>

10<3

/8>

300<

11-1

3/16

>

150<5-29/32>287.5<11-11/32>

500<19-11/16>

800<31-1/2>

69<2-23/32>

183<7-7/32>

90<3

-17/

32>

155<

6-3/

32>

23<29/32>

32.5

<1-9

/32>

18<23/32>

FLARE {12.7<1/2>

FLARE {6.35<1/4>

Installation bolt pitch

PIPING-WIRING DIRECTION

Minimum installation space for outdoor unit

Free space around the outdoor unit(basic example)

FOUNDATION BOLTS

Unit: mm<in>

Air discharge

Air intake

Air intake

oval hole2-10×21

drain holeø 42 2-U Shaped notched holes

(Foundation Bolt M10<W 3/8>)

(Foundation Bolt M10<W 3/8>)

330<

13>

300<

11-1

3/16

>

40 <1-19/32>

404.5<15-15/16>

48<1

-29/

32>

360<

14-3

/16>

32.5

<1-9

/32>

500<19-11/16>

Min.500mm<19-11/16>

Min.100mm <3-15/16>

Service portFLARE 12.7 (1/2F)

Connection forgas pipe

FLARE ø

ø

6.35 (1/4F)Connection forliquid pipe

Service panelfor charge plug

Service panelEarth terminal

Terminal connectionLeft ... Power supply wiringRight ... Indoor/Outdoor wiring

23.2<15/16>

99.5

<3-1

5/16

>16

4.5<

6-1/

2>49

2<19

-3/8

>

185.5 <7-5/16>

43 °35 °

2-ø22.2<7/8>1/2 conduit hole

Installation bolt pitch

Handle for moving

22 <7/8>

320<

12-5

/8>

809 <31-7/8> 62 <2-15/32>

154.5 <6-3/32>

310 <12-7/32>

8.5<

11/3

2>

22.3 <29/32>

630

<24-

13/1

6>

Min.100mm<3-15/16>

Basic

ally

open

Min.350mm <13-25/32>

Max.

<Foundation bolt height>

18m

m<2

3/32

>

Free space around the outdoor unit(basic example)

100mm<3-15/16> or more as long asno obstacle is placed on therear and right-and-left sidesof the unit

2 sides should be open in the right, left and rear side.

Please secure the unit firmlywith 4 foundation (M10<W3/8>) bolts.(Bolts, washers and nut must be purchased locally).

FOUNDATION BOLTS

Piping and wiring connection canbe made from the rear direction only.

PIPING-WIRING DIRECTION

FOUNDATION

OCH636

FORM# PLA-A18EA7 / PUY-A18NKA7(-BS) - 201810

1340 Satellite Boulevard, Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com

DIMENSIONS: PLA-A18EA7 & PUY-A18NKA7 (-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.