Booster Enclosure Corrector Prototype Installation
Filter InstallationDissolved O2
Update
7/6/07
Maurice BallFluids Engineering
AD/Mechanical Support
![Page 2: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/2.jpg)
Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,Start: Wed 7/11/2007 9:30 AMEnd: Wed 7/11/2007 11:30 AMRecurrence: (none)http://www.liqui-cel.com/http://www.industry.siemens.com/Water/en/http://www.industry.siemens.com/Water/en/?gkey=[us+filter]&gr=Branded&s=g&WT.srch=1
Us Filter-Interlake2600 S 17th AveBroadview, IL 60155#(708) 345-7672Broadview Sales person for Siemens Water TechnologyJanine Pigue #(708) 345-7290Discuss modifying the system to accommodate Pbar and Booster LCW SystemsUpgrade Liqui-cel membrane contactors with higher pressure rating, remove booster pumps
![Page 3: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/3.jpg)
Filter for Booster Installation Prototype
• http://www.shelco.com/pdfs/MH_final.pdf• Pleated polypropylene media cartridge
– 0.5 micron, 90% efficiency rating– Over 5-1/2 square feet of media, very high dirt
holding capacity than other cartridges.– $24 each
• Pressure drop vs GPM at 0.5 micron– At 2 GPM, delta P at less than 1 PSID– Recommended Changeout 25 PSID
![Page 4: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/4.jpg)
![Page 5: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/5.jpg)
![Page 6: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/6.jpg)
![Page 7: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/7.jpg)
![Page 8: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/8.jpg)
![Page 9: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/9.jpg)
Filter Monitoring
• Tap on Filter housing for inlet and outlet pressure monitoring
• Local pressure gauges• Remote Pressure Transducers,
– 0.5% of full scale accuracy– 4-20 mA output signal– Remote monitoring from Main Control Room
• Acknowledgement to Kent Triplett, – Sensor testing and verification– Loop Power Source, 10-30 VDC
![Page 10: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/10.jpg)
Alarm Set Point
• Filter Delta P Clean, at 1 GPM, 0.3 PSID
• Corrector needs 80 PSID for 0.6 GPM
• Booster 95 LCW System provides S=120 PSID min
![Page 11: Subject: Meeting with Janine Pigue of Siemens Water Technology, formerly US Filter,](https://reader036.fdocuments.in/reader036/viewer/2022081520/568154d0550346895dc2d006/html5/thumbnails/11.jpg)
Bottom Line
• Installing Small Filter in Enclosure will teach us :– Impact on New Corrector Program– Health of the Booster 95 LCW System– Protect prototype corrector during critical