STX110 MIPTEC Flyer - LiCONiC · the instrument placed on the table surface (BenchTop BT) o rfo...
Transcript of STX110 MIPTEC Flyer - LiCONiC · the instrument placed on the table surface (BenchTop BT) o rfo...
- Integrated Plate Handling - Stand-Alone or Bench-Top- Heated or Cooled Versions
STX110STX Automated Incubator
Access through full-sizeduser door
Access through the smallrobotic gate
1155
20 - 35
200
300
819
20
Tran
sfer
Hei
ght
42661
716
485
1203
20-35
819
288
80
15
1000
Tran
sfer
Hei
ght
42661
485
716
716
485Standard Gate Location
Mirrored Gate Location (Option MR)
485
716
Standard Gate Location
Mirrored Gate Location (Option MR)
Bench-Top (BT) Stand-Alone (SA)Dimensions
Cl imate Opt ions
STX110-IC
STX110-HC
STX110-DC2
STX110-HR
STX110-DR
STX110-AR
STX110-DF
STX110-NC
33..50°C (70°C)
04..25°C
04..25°C
04..50°C (70°C)
04..50°C
04..50°C
-20..0°C
-
max. 95%
max. 90%
04..50%
90..95%
02..50%
10..95%
02..45%
-
Incubator
Humid Cooler
Dry Storage
Humid Wide Range
Dry Wide Range
Humidity Controlled
Deep Freezer
No Climate
9131 00 00
9131 05 00
9131 05 25
9131 05 01
9131 05 07
9131 05 12
9131 05 14
9131 05 28
9131 05 03
9131 05 04
9131 05 26
9131 05 05
9131 05 08
9131 05 15
9131 05 19
9131 05 29
Temperature HumidityOrder Nr.
STX110 Stand AloneOrder Nr.
STX110 Bench TopType Description
1)
1) 3)
1)
1) 3)
1) 2)
1)
1) Humidity depends on temperature setting / 2) Humidity Adjustable / 3) Adjustable dehumidification / 4) up to +20°C on request
STX110The STX110 is the world's smallest carousel based automated incubator. The STX110 slim 400 mm width minimises room required along a robotic line. Yet, keeping size constraints in mind, these units can be stacked to increase production needs.
The STX110 features LiCONiC's new Flush Gate and LiCONiC's new speed optimised handling. The Flush Gate
area.
Information within this document is subject to be changed without prior notice. For details please contact our applications. [email protected]
Options
High temperature 70°C capability
Bar Code Reader Option
Plate Presence Sensor
Disposal Tips upgrade kit up to 100mm height
Fast access for time critical applications
N-Way Decontamination
Liconel self decontaminating incubator chamber
Linear Shaker, Amplitude 1-100mm, 12-300 rpm
UCI Universal Communication Interface
Steam Injection
Side Gate (left side wall, seen from front)
Mirrored Gate LOcation, on back wall (MR)
9122 06 02
9118 11 03
9121 00 62
9118 12 23
9111 10 00
9122 05 28
9131 05 11
9131 00 18
9118 11 17
9118 11 16
9131 05 20
9131 05 30
Fast CO2 Gassing Option
Fast N2 Gassing Option
Fast O2 Gassing Option
Additional CO2 Gassing Option
Additional N2 Gassing Option
Additional O2 Gassing Option
9118 11 12
9118 11 13
9118 11 14
9118 11 07
9118 11 11
9118 11 08
.rN redrO.rN redrO
NTP (Nanotiter Plates)
1536
MTP (Microtiter Plates)
DWP (Deep Well Plates)
DiTi200
DiTi1000
5 mm
11 mm
12 mm
17 mm
22 mm
23 mm
24 mm
27 mm
44 mm
53 mm
66 mm
104 mm
210
140
135
110
85
85
85
75
50
40
35
20
Capaci tyPlate HeightPlate Type Plate capacity
of unit
22.05.2014 © Liconic AG
www.Liconic.comEurope & International: Liconic AG, Liechtenstein
UK & Nordic: Liconic UK Ltd, ManchesterUS & Asia: Liconic Inc, Woburn MA
The STX110 instruments are available for integration with the instrument placed on the table surface (BenchTop BT) or for integration with the instrument standing on the
The combination of a StandAlone
Top allow these units to be stacked.