STX110 MIPTEC Flyer - LiCONiC · the instrument placed on the table surface (BenchTop BT) o rfo...

2
- Integrated Plate Handling - Stand-Alone or Bench-Top - Heated or Cooled Versions STX110 STX Automated Incubator

Transcript of STX110 MIPTEC Flyer - LiCONiC · the instrument placed on the table surface (BenchTop BT) o rfo...

Page 1: STX110 MIPTEC Flyer - LiCONiC · the instrument placed on the table surface (BenchTop BT) o rfo integration with the instrument standing on the The combination of a StandAlone Top

- Integrated Plate Handling - Stand-Alone or Bench-Top- Heated or Cooled Versions

STX110STX Automated Incubator

Page 2: STX110 MIPTEC Flyer - LiCONiC · the instrument placed on the table surface (BenchTop BT) o rfo integration with the instrument standing on the The combination of a StandAlone Top

Access through full-sizeduser door

Access through the smallrobotic gate

1155

20 - 35

200

300

819

20

Tran

sfer

Hei

ght

42661

716

485

1203

20-35

819

288

80

15

1000

Tran

sfer

Hei

ght

42661

485

716

716

485Standard Gate Location

Mirrored Gate Location (Option MR)

485

716

Standard Gate Location

Mirrored Gate Location (Option MR)

Bench-Top (BT) Stand-Alone (SA)Dimensions

Cl imate Opt ions

STX110-IC

STX110-HC

STX110-DC2

STX110-HR

STX110-DR

STX110-AR

STX110-DF

STX110-NC

33..50°C (70°C)

04..25°C

04..25°C

04..50°C (70°C)

04..50°C

04..50°C

-20..0°C

-

max. 95%

max. 90%

04..50%

90..95%

02..50%

10..95%

02..45%

-

Incubator

Humid Cooler

Dry Storage

Humid Wide Range

Dry Wide Range

Humidity Controlled

Deep Freezer

No Climate

9131 00 00

9131 05 00

9131 05 25

9131 05 01

9131 05 07

9131 05 12

9131 05 14

9131 05 28

9131 05 03

9131 05 04

9131 05 26

9131 05 05

9131 05 08

9131 05 15

9131 05 19

9131 05 29

Temperature HumidityOrder Nr.

STX110 Stand AloneOrder Nr.

STX110 Bench TopType Description

1)

1) 3)

1)

1) 3)

1) 2)

1)

1) Humidity depends on temperature setting / 2) Humidity Adjustable / 3) Adjustable dehumidification / 4) up to +20°C on request

STX110The STX110 is the world's smallest carousel based automated incubator. The STX110 slim 400 mm width minimises room required along a robotic line. Yet, keeping size constraints in mind, these units can be stacked to increase production needs.

The STX110 features LiCONiC's new Flush Gate and LiCONiC's new speed optimised handling. The Flush Gate

area.

Information within this document is subject to be changed without prior notice. For details please contact our applications. [email protected]

Options

High temperature 70°C capability

Bar Code Reader Option

Plate Presence Sensor

Disposal Tips upgrade kit up to 100mm height

Fast access for time critical applications

N-Way Decontamination

Liconel self decontaminating incubator chamber

Linear Shaker, Amplitude 1-100mm, 12-300 rpm

UCI Universal Communication Interface

Steam Injection

Side Gate (left side wall, seen from front)

Mirrored Gate LOcation, on back wall (MR)

9122 06 02

9118 11 03

9121 00 62

9118 12 23

9111 10 00

9122 05 28

9131 05 11

9131 00 18

9118 11 17

9118 11 16

9131 05 20

9131 05 30

Fast CO2 Gassing Option

Fast N2 Gassing Option

Fast O2 Gassing Option

Additional CO2 Gassing Option

Additional N2 Gassing Option

Additional O2 Gassing Option

9118 11 12

9118 11 13

9118 11 14

9118 11 07

9118 11 11

9118 11 08

.rN redrO.rN redrO

NTP (Nanotiter Plates)

1536

MTP (Microtiter Plates)

DWP (Deep Well Plates)

DiTi200

DiTi1000

5 mm

11 mm

12 mm

17 mm

22 mm

23 mm

24 mm

27 mm

44 mm

53 mm

66 mm

104 mm

210

140

135

110

85

85

85

75

50

40

35

20

Capaci tyPlate HeightPlate Type Plate capacity

of unit

22.05.2014 © Liconic AG

www.Liconic.comEurope & International: Liconic AG, Liechtenstein

UK & Nordic: Liconic UK Ltd, ManchesterUS & Asia: Liconic Inc, Woburn MA

The STX110 instruments are available for integration with the instrument placed on the table surface (BenchTop BT) or for integration with the instrument standing on the

The combination of a StandAlone

Top allow these units to be stacked.