    DESIGN EXAMPLES

    The following five structural design examples demonstrate the significant savings which can

    be achieved in the areas of weight and cost by using Grade 690 MPa Bisplate 80 steel

    instead of the more commonly used lower grade structural steels. These examples primarily

    compare Bisplate 80 to Grade 300 Plus Steel which is currently the most commonly usedstructural steel in Australia. Comparison with other steels are noted where appropriate.

    The design examples are as follows:

    Heavily Loaded Column

    Heavily Loaded Beam - I section

    Heavily Loaded Beam - Box section

    Heavily Loaded Truss

    70 MI Water tank

    Where appropriate, these examples have been simplified as much as possible in order tofacilitate ease of comparison between the different steels. Each example contains a brief

    explanation of the structural element and the loading applied. Also provided are some typical

    examples of applications in which the structural element may be utilised.

    DESIGN CODES RELATING TO THE USE OF HIGH STRENGTH QUENCHED AND TEMPERED PLATE

    MEMBERS IN STRUCTURAL ENGINEERING APPLICATIONS.

    There is currently no Australian Standard covering the design of structural elements utilising

    high strength quenched and tempered steels. The SAA Steel Structures Code, AS 4100-1990,

    may be used for the design of structures in steel grades up to 450 MPa, beyond which the

    general provisions of the code are not applicable.

    AS4100 does not exclude the use of structural steels in excess of 450 MPa yield stress.

    However, in order to adequately design and demonstrate the validity of a design in such

    steels, it is necessary to engage an appropriate international standard which has been

    specifically developed to cater for the use of high strength steels.

    One such code, and the most commonly used in Australia for design in high strength steels is

    the American Institute of Steel Constructions (AISC) Specification For Structural Steel

    Buildings - Allowable Stress Design and Plastic Design, June 1, 1989. This code has been

    proven to provide relatively simple and efficient methods of structural design for all types ofstructural elements, and has been used in the development of each of the design examples

    contained within this publication.

    A limit state version of the AISC specification is also available, and should be equally

    effective in the design of High Strength Steel structures. It should also be noted that Bisplate

    80 steel, at 690 MPa yield stress, is right on the upper limit of 100 ksi yield stress steel

    covered by the AISC specification. Above this yield stress the AISC specification is not

    applicable.

    2 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    3/13

    Bisalloy Design Examples

    EXAMPLE 1

    HEAVILY LOADED COLUMN

    Consider a braced column, 10m high, loaded

    axially with an 11,000 KN factored live load

    (Fig. 1).

    Some examples of practical applications where

    such a column may be required are as follows:

    In multi-storey construction

    Heavy industrial structures

    Storage silos/Hopper supports

    Structural column design was carried out

    for Grade 300 MPa steel using AS4100-1990. C

    Corresponding design was carried out forGrade 690 MPa Bisplate 80 Steel using the

    AISC specification.

    The results of each design are summarised in Table 1. Representative calculations are

    provided on following pages.

    STEEL GRADE MPa SECTION WEIGHT Kg/m300 500WC383 383

    690tf = 20 d1 = 400tw = 16 bf = 500

    207

    3 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    4/13

    Bisalloy Design Examples

    COLUM DESIGN USING GRADE 300STEEL COLUMN DESIGN USING GRADE 690MPA YIELDDesign in accordance with AS4100 1900.

    Fig 3

    AS4100 500WC383Reference

    Section Capacity6.2.1 NS = KfAnfy

    An=Ag=Ae

    Kf = 1.0

    Ns = 13664 KN

    Ns = 12,298 KN > N* OK

    Member Capacity6.3.3 Nc = c Ns N

    c = {[1-[1-(90/)2]}= 0.8945Nc = 12,222 KN

    Nc = 11,000 KN N* OK

    Nominal Mass of Column = 383 kg/m

    STRENGTH BISPLATE 80

    Design in accordance with American Institute of Steel

    Construction Specification for Structural Steel Buildings - 1989.Ag = 48,800 mm

    2

    Ix = 1,890 x 106mm4

    Iy = 751 x 106mm4

    rx = 197mm

    ry = 124mm

    fy = 280 MPa

    AISC Spec. Design Load = 11,000 =7,333KN

    Reference 1.5

    fa = 7,333 = 277.78 MPaAg

    Fa = 40.29 ksi

    B5 Check Local Buckling

    Table B5.1 Flanges : 95 = 95 = 9.5 < b = 12.1

    Fy 100 t

    Kc 1.0

    Slender Element

    Table B5.1 Web: 253 = 253 = 25.3 > b = 25.0

    Fy 100 t

    Non-Compact Element

    Slender elements involved

    Design by Appendix B

    App. B Stress Reduction Factor for Flange,

    B5a Qs = 1.293 0.00309 b Fy = 0.907

    t Kc

    Stress Reduction Factor for Web,

    Qa = 1.0

    Member stress reduction factor,

    Q = QsQa = 0.907

    Ag = 26,400 mm2 = An = Ae

    Iy = 416.8 x 106mm4

    Ry = Iy A = 125.7mm

    fy = 690 MPa

    = 100 Ksi

    4 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    5/13

    Bisalloy Design Examples

    COLUMN DESIGN USING GRADE 690MPA YIELD

    STRENGTH BISPLATE 80(CONTINUED)

    AISC Spec.

    Reference

    B5c Allowable Stress, Fa

    C1c = 79.44 > kl

    r

    kl2

    r

    Q 1 - Fy2Cc

    ,2

    Fa =

    Eq A-B5-11 kl kl3

    5 3 r r

    3 + 8Cc 8Cc3

    Fa = 43.13ksi > fa OK

    Nominal mass of Column = 208 kg/m

    5 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    6/13

    Bisalloy Design Examples

    EXAMPLE 2

    HEAVILY LOADED BEAM (ISECTION)

    Consider a beam with full lateral restraint spanning 10m, loaded continuously with a live load of 470

    KN/m (factored) as shown in Fig.5.

    Practical applications where such a beam ma

    required are:

    In multi-storey construction

    Heavy industrial structures

    Roof support in underground mining

    Structural beam design was carried out for Grade 300 MPa steel using AS4100-1990. Corresponding

    design was carried out for Grade 690 MPa Bisplate 80 steel using the AISC specification.

    The results of each design are summarised in Table 2. Representative calculations are provided on the

    following pages.

    STEEL GRADEMPa

    SECTION WEIGHT Kg/m

    300 1200WB392 392

    690

    tf= 25 d1 = 850

    tw = 12 bf = 450 256

    Note that a significant reduction in the depth of the beam was achieved through the use of Bisplate 80, in addition to the

    weight waving, while still satisfying the permissible deflection requirements. This is of great importance in underground

    mining and multi-storey construction applications, where head room is at a premium.

    6 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    7/13

    Bisalloy Design Examples

    BEAM DESIGN USING BEAM DESIGN USING GRADE 690MPA

    GRADE 300STEEL YIELD STRENGTH BISPLATE 80Design in accordance with AS4100 1990.

    7 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    8/13

    Bisalloy Design Examples

    EXAMPLE 3

    HEAVILY LOADED BEAM (BOX SECTION)

    Consider a beam with full lateral restraint spanning 10m, loaded continuously with a live load of 470

    KN/m (factored) as shown in Fig 9.

    Practical applications are :

    Heavy industrial structures

    Roof support in mining

    A box section is effective in long spans where additional lateral restraint is required within the

    beam section to compensate for a lack of external restraints.

    A common application ofabox section fabricated from high strength Q & T steel in

    which the load configuration varies significantly from that described above, is in the

    lifting booms ofmobile cranes.

    Structural beam design was carried out for both Grade 250 MPa steel and Grade 690 MPa

    Bisplate 80 steel using the AISC specification.

    The results of each design are summarised in Table 3. Representative calculations are

    provided on the following pages.

    Table 3:

    STEEL GRADEMPa

    SECTION WEIGHT Kg/m

    250

    tf= 40 d1 = 1120

    tw = 10 bf = 500 490

    690tf= 25 d1 = 850

    tw = 8 bf = 450284

    8 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    9/13

    Bisalloy Design Examples

    BOX SECTION BEAM DESIGN USING BOX SECTION BEAM DESIGN USING

    GRADE 250MPA ASTMA36 GRADE 690MPA BISPLATE 80

    In accordance with AISC Spec. In accordance with AISC Spec.

    9 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    10/13

    Bisalloy Design Examples

    EXAMPLE 4

    HEAVILY LOADED TRUSS

    Consider a heavily loaded truss spanning 40m.

    Some examples of practical applications where such a truss may be required include :

    Underground construction supporting a trafficable roof

    (e.g. a hydro-electric power station).

    Multi-storey construction supporting several floors.

    In this example the following loading parameters have been considered.

    Truss spacing 10m

    Live Load 3 KPa

    Dead Load 1 KPa

    Occasional Load 20 KN mid span

    The resulting load configuration is illustrated in Fig.13.

    10 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    11/13

    Bisalloy Design Examples

    Structural member design was carried out for Grade 300 and 350 MPa steels using AS4100

    1990. Corresponding design was carried out for Grade 690 Bisplate 80 steel using the

    American Institute of Steel Construction Specification for Structural Steel Buildings. Results

    are summarised in Tables 4 and 5.

    TRUSS DESIGN SUMMARY

    Grade 300 & 350 MPa AS4100 1990

    Table 4:MEMBER SECTION kg/m TOTAL LENGTH

    mTOTAL WEIGHT

    TONNES

    Top Cord 310 UC 137 137 40 5.480

    Bottom Cord 310 UC 96.8 96.8 40 3.872Webs 250 UC89.5

    * (250 x 250 x 6 SHS)

    89.5

    (45)

    87.3

    (87.3)

    7.814

    (3.929)

    Total Weight = 17.166(13.281)

    *Figures in brackets correspond to the use of Grade 350 square

    Hollow Sections as web members.

    All other members are Grade 300.

    Grade 690 Bisplate 80 AISC Spec.

    Table 5:MEMBER SECTION kg/m TOTAL LENGTH

    mTOTAL WEIGHT

    TONNES

    Top Cord tf = 10 d1 = 212tw = 8 bf = 256

    55 40 2.200

    Bottom Cord tf = 10 d1 = 212tw = 10 bf = 260

    58 40 2.320

    Webs tf = 8 d1 = 225tw = 6 bf = 256

    43 87.3 3.754

    Total Weight = 8.274

    11 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    12/13

    Bisalloy Design Examples

    EXAMPLE 5

    REVISED DESIGN FOR A LARGE WATERSTORAGE TANK

    A water storage tank was originally designed in AS3678-1990 Grade 250 and 350 steel plateto the following parameters:

    Height = 14.25m

    Diameter = 83.8m

    Capacity = 70 MI

    The stress calculations for the original design are as shown in Table 6.

    Table 6::DEPTH (m) PRESSURE

    (KPa)

    HOOP

    TENSION(KN/m)

    PLATE YIELD

    STRENGTH(MPa)

    PLATE

    THICKNESS(mm)

    STRESS

    (MPa)

    2.85 28.5 1194 250 10 1195.70 57.0 2388 250 20 119

    8.55 85.5 3582 250 25 14311.40 114.0 4777 350 28 17114.25 142.5 5971 350 36 166

    A revised design incorporating 690 MPa yield strength Q & T steel plates in the lower two

    sections produced the following set of values, shown in Table 7.

    Table 7:

    DEPTH (m) PRESSURE(KPa)

    HOOPTENSION

    (KN/m)

    PLATE YIELDSTRENGTH

    (MPa)

    PLATETHICKNESS

    (mm)

    STRESS(MPa)

    2.85 28.5 1194 250 10 1195.70 57.0 2388 250 20 1198.55 85.5 3582 250 20 17911.40 114.0 4777 690 20 23914.25 142.5 5971 690 20 298

    As shown in Fig. 15, this revised design resulting in a saving of 25% in the mass of steelwork

    in the walls of the tank.

    12 of 13 11 Aug 2006 Rev 1.

  • 8/3/2019 Structural Design Examples

    13/13

    Bisalloy Design Examples

    Please Note:Every care has been taken to ensure the accuracy of the design examples, however, the information is provided

    as a guide only. A structural engineer should be consulted with respect to use for specific projects. Bisalloy doesnot warrant the suitability of the design examples for a particular purpose. The purchaser relies on its own skilland judgement as to the suitability of Bisalloy 80 (Bisplate 80) for its purpose.Bisalloy Steels shall not be liable for any loss or damage howsoever caused arising from the application of such

    information.

    13 of 13 11 Aug 2006 Rev 1.