39
Strengthening Steel Girder Bridges Strengthening Steel Girder Bridges with CFRP Plates with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee Bridge Engineering Center Iowa State University A.H. Al-Saidy Dept of Civil and Arch Engineering Sultan Qaboos University

Transcript of Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP...

Page 1: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Strengthening Steel Girder Bridges Strengthening Steel Girder Bridges with CFRP Plateswith CFRP Plates

T. J. Wipf B. M. PharesF. W. Klaiber Y. S. Lee

Bridge Engineering CenterIowa State University

A.H. Al-Saidy

Dept of Civil and Arch EngineeringSultan Qaboos University

Page 2: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Overview:Overview:Overview:Laboratory Investigation:– Evaluated the feasibility of using CFRP plates in

strengthening steel-concrete composite beams

– Tested ten small-scale, steel-concrete composite beams» Two different arrangements of CFRP and two different

levels of damage were investigated

Field Investigation:– Used CFRP plates to strengthen an existing, structurally deficient

steel girder bridge– Investigating short- and long-term effectiveness– Identified changes in structural behavior due to the addition of the

strengthening system

Page 3: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Advantages of CFRP:Advantages of CFRP:Advantages of CFRP:

Corrosion resistantLight weightHigh strength with a high fatigue lifeCan be installed with a minimal crew and common equipment

Page 4: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Nonlinear Analysis:Nonlinear Analysis:Nonlinear Analysis:

Developed and validated an analytical model to investigate the impact of the following variables:

– Area of the tension flange removed– CFRP plate ultimate strain– Area of CFRP added – CFRP stiffness– Compressive strength of deck slab concrete– Yield strength of the steel section being strengthened

Page 5: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Experimental Investigation:Experimental Investigation:Experimental Investigation:

Undamaged beam

Concreteslab

32”

3”

W8X15

CFRP Plates

Concreteslab

32”

3”

W8X15Removed part of flange

Damaged beam

Page 6: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Experimental ConfigurationExperimental ConfigurationExperimental Configuration

Hydraulic cylinder

Reaction steel tubes

Load cellSteel plates

Concretesupport

CFRP plate

Neoprenepad

48” 36”

Page 7: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Failure ModesFailure ModesFailure Modes

CFRP plate ruptureConcrete crushing

Page 8: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Analytical Midspan DeflectionAnalytical Analytical MidspanMidspan DeflectionDeflection

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

0 0.5 1 1.5 2 2.5 3 3.5Deflection (in.)

Load

(lbs

) D75

D50

U

Page 9: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Impact of Repair Scheme 1Impact of Repair Scheme 1Impact of Repair Scheme 1

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

0 0.5 1 1.5 2 2.5 3

Deflection (in.)

Load

(lbs

) D50

U

D50R1E29

Page 10: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Impact of Repair Scheme 2Impact of Repair Scheme 2Impact of Repair Scheme 2

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

40,000

0 0.5 1 1.5 2 2.5 3

Deflection (in.)

Load

(lbs

)

D50

U

D50R2E29

Page 11: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Description of Bridge:Description of Bridge:Description of Bridge:Located in Pottawattamie County, IA on State Highway IA 92Three-span continuous steel girder bridgeRoadway width = 30 ft [ two traffic lanes ]Total length = 150 ft– Two 45.5 ft end spans and

a 59 ft center span

Page 12: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Description of Bridge (continued)Description of Bridge (continued)Description of Bridge (continued)

Constructed in 1938, the bridge was originally non-composite

In 1967, it was widen by adding two composite exterior girders

Page 13: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Strengthening SystemStrengthening SystemStrengthening System

13'-6" 13'-6"

BEAM 1 (EXTERIOR 27WF84)

LCCFRP PLATE

10'-0"

BEAM 3 (INTERIOR 27WF98)

10'-0" 12'-6"

10'-0"

20'-6"

12'-6"

BEAM 4 (INTERIOR 27WF98)

BEAM 6 (EXTERIOR 27WF84)

10'-0" 12'-6"

12'-6"

CFRP PLATE

CFRP PLATECL LC

CFRP PLATE

9" x 34 " x 12'-6" COV. P

9" x 916 " x 10'-6"

COV. PLL

F

F

E

E

F

F

G

G

20'-6"

J

J

I

I

H

H

I

I L

L

K

K

L

L

M

MCFRP PLATE

Page 14: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Cutting FRP Strips to the Desired LengthsCutting FRP Strips to the Desired Cutting FRP Strips to the Desired LengthsLengths

Page 15: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Removal of Paint from Beams – Stage 1Removal of Paint from Beams Removal of Paint from Beams –– Stage 1Stage 1

Page 16: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Removal of Paint from Beams – Stage 2Removal of Paint from Beams Removal of Paint from Beams –– Stage 2Stage 2

Page 17: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Cleaned SurfaceCleaned SurfaceCleaned Surface

Page 18: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Cleaning of FRP StripsCleaning of FRP StripsCleaning of FRP Strips

Page 19: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Field Cleaning of FRP StripsField Cleaning of FRP StripsField Cleaning of FRP Strips

Page 20: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Final Cleaning of Beam FlangesFinal Cleaning of Beam FlangesFinal Cleaning of Beam Flanges

Page 21: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Installation of FRS PrimerInstallation of FRS PrimerInstallation of FRS Primer

Page 22: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Application of ECS 104 Structural EpoxyApplication of ECS 104 Structural EpoxyApplication of ECS 104 Structural Epoxy

Page 23: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Application of ECS 104 Structural EpoxyApplication of ECS 104 Structural EpoxyApplication of ECS 104 Structural Epoxy

Page 24: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Obtaining Desired Thickness of EpoxyObtaining Desired Thickness of EpoxyObtaining Desired Thickness of Epoxy

Page 25: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Application of Epoxy to Beam FlangesApplication of Epoxy to Beam FlangesApplication of Epoxy to Beam Flanges

Page 26: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Installation of FRP Strips to End Span BeamsInstallation of FRP Strips to End Installation of FRP Strips to End Span BeamsSpan Beams

Page 27: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Installation of FRP Strips to End Span Beams ( continued )Installation of FRP Strips to End Installation of FRP Strips to End Span Beams ( continued )Span Beams ( continued )

Page 28: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Installation of FRP Strips to Center Span BeamsInstallation of FRP Strips to Center Installation of FRP Strips to Center Span BeamsSpan Beams

Page 29: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Installation of FRP Strips to Center Span Beams ( continued )Installation of FRP Strips to Center Installation of FRP Strips to Center Span Beams ( continued )Span Beams ( continued )

Page 30: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Rolling of installed FRP PlatesRolling of installed FRP PlatesRolling of installed FRP Plates

Page 31: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Completed Installation of FRP PlatesCompleted Installation of FRP PlatesCompleted Installation of FRP Plates

One layer (West end span) Three layers (East end span)

Page 32: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Load TestingLoad TestingLoad TestingHalf of bridge was instrumented 3-axle truck used in three different load paths Data collected continuously as truck crossed the bridgeInitial test and two follow-up testscompleted to date

N

4'-1.5"

4'-1.5"

8'-8"

CL3'-0"

LEGEND :

BEAM TRUCK PATH

Y3

Y2

Y1

LOADWAY

4'-0"

8'-5"

6'-9"

8'-5"

4'-0"

BEAM 1

BEAM 6

Page 33: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Live-load Flexural ResponseLiveLive--load Flexural Responseload Flexural ResponseElastic behaviorConsistency in strains with time

-60-40-20

020406080

100120

0 50 100 150 200

Truck Position, ft

Mic

rost

rain

Initial Test (Top)Initial Test (Bottom)t=0 year (Top)t=0 year (Bottom)t=1 year (Top)t=1 year (Bottom)

Page 34: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Bond PerformanceBond PerformanceBond PerformanceCritical to have adequate bond for force transferGages installed on CFRP plate to investigate the bond performanceAnalytical model developed based on strain compatibility relationExtreme fiber strains were predicted and compared with experimental data

CFRP PLATE

STRAIN GAGE

εTB

εEXT

εT

hwebhCFRP

εEXT = − εT (εT + εTB) * hCFRP

hweb

Page 35: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Bond PerformanceBond PerformanceBond Performance

-60-40-20

020406080

100120

0 50 100 150 200

Truck Position, ft

Mic

rost

rain

t=0 year (CFRP)t=1 year (CFRP)Analytical

Page 36: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Concluding Remarks….Concluding RemarksConcluding Remarks……..

Strength of damaged steel girders can be fully restored with the use of CFRP plates

Stiffness of repaired steel girders is greater than that of the damaged girder, however not fully restored to that of the undamaged girder

Page 37: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Concluding Remarks [continued]…Concluding Remarks [continued]Concluding Remarks [continued]……

CFRP plates have minimal impact on changing the member’s stiffness but can have a relatively large impact on changing member strength, ……if properly designed

Bond performance after one-year of service was good

Page 38: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Concluding Remarks [continued]….Concluding Remarks [continued]Concluding Remarks [continued]……..

The use of CFRP plates appears to be a viable strengthening alternative for steel girder bridgesHandling and installation of CFRP plates was initially relatively labor intensive and required some trainingA three-man crew was needed to install the system

Page 39: Strengthening Steel Girder Bridges with CFRP Plates · Strengthening Steel Girder Bridges with CFRP Plates T. J. Wipf B. M. Phares F. W. Klaiber Y. S. Lee ... Application of ECS 104

Sponsorship:Sponsorship:Sponsorship:

Project was initiated by the Iowa Department of Transportation

and was funded through the Federal Highway Administration’s Innovative Bridge Research and Construction[IBRC] Program