STRENGTHENING OF REINFORCED CONCRETE COLUMNS...
Transcript of STRENGTHENING OF REINFORCED CONCRETE COLUMNS...
STRENGTHENING OF REINFORCED CONCRETE COLUMNS USING
FRP FABRIC
SHUJAATULLAH SHEIKH
A project report submitted in partial fulfillment of the
requirements for the award of the degree of Master of Engineering
(Civil – Structure)
Faculty of Civil Engineering
Universiti Teknologi Malaysia
JANUARY 2012
iii
To my beloved family…
iv
ACKNOWLEDGEMENTS
First and foremost the author wishes to express his profound gratitude to his
research supervisor Associate Professor Dr. Abdul Rahman Mohd. Sam for his
guidance and valuable advice throughout the research period. His insight into the
behaviour of CFRP-concrete substrate was of immense help in the preparation of this
thesis.
The author would also like to thank his brother Dr. Usman Ullah Sheikh in
proofreading the final draft and for his many technical comments.
Last but not least, the author remembers his family, especially his mother, for
her countless blessings which have always been a source of inspiration in achieving
success up to this level.
v
ABSTRACT
In a number of cases, the compressive strength of reinforced concrete
members have been found to be less than the design strength. Therefore, forcing the
structural engineer to strengthen these members in order to cater for the dead, super-
dead and superimposed loads to which these structural members are subjected to
throughout their service life. In the case of under-strength columns, an efficient
method of increasing the strength and ductility of these columns is by wrapping them
with fibre-reinforced polymer (FRP) fabric. However, most previous studies on
concrete short columns confined with FRP sheets were based on small-scale testing
which did not take into consideration the size effect of these columns. In this study,
40 MPa concrete cylinders having height-to-width ratios (λ) of 4 and 8 are wrapped
with CFRP sheets impregnated with epoxy and tested under uniaxial compression.
Their ultimate failure loads are recorded and the performance of the wrapped
cylinders is compared to the unwrapped control specimens in terms of the strength
gain produced by the confining effects of the wraps.
vi
ABSTRAK
Dalam beberapa kes, kekuatan mampatan struktur konkrit bertetulang
didapati tidak mencapai kekuatan rekabentuk. Justeru itu, jurutera struktur terpaksa
mencadangkan agar langkah-langkah penambahbaikan dilakukan terhadap struktur-
struktur yang lemah ini untuk membolehkan struktur-struktur berkenaan terus dapat
menanggung beban hidup dan beban mati yang dikenakan dengan selamat. Salah
satu kaedah yang efisien untuk menguatkan struktur tiang konkrit yang lemah adalah
dengan membalut tiang berkenaan dengan jaket FRP (serat polimer yang diperkuat).
Dalam kajian ini, silinder konkrit gred 40 MPa dengan nisbah kelangsingan (λ)
bersamaan 4 dan 8 dibalut dengan CFRP (serat karbon polimer yang diperkuat) dan
diuji di bawah aplikasi daya mampatan. Beban puncak direkodkan serta kelakunan
sampel silinder konkrit yang berbalut dibandingkan dengan sampel kawalan yang
tidak dibalut daripada segi kesan penambahbaikan yang mungkin dihasilkan oleh
balutan CFRP berkenaan.
vii
TABLE OF CONTENTS
CHAPTER TITLE PAGE
DECLARATION ii
DEDICATION iii
ACKNOWLEDGEMENTS iv
ABSTRACT v
ABSTRAK vi
TABLE OF CONTENTS vii
LIST OF TABLES ix
LIST OF FIGURES x
LIST OF SYMBOLS xii
LIST OF ABBREVIATIONS xiv
LIST OF APPENDICES xv
CHAPTER 1 INTRODUCTION 1
1.0 Introduction 1
1.1 Objectives of the study 7
1.2 Scope of the study 7
1.3 Case study 8
CHAPTER 2 LITERATURE REVIEW 9
2.1 Introduction 9
CHAPTER 3 RESEARCH METHODOLOGY 15
3.1 Introduction 15
3.2 Concrete 18
viii
3.3 Reinforcement 19
3.4 Compression Testing of Samples 23
CHAPTER 4 RESULTS AND DISCUSSION 24
4.1 Introduction 24
4.2 Concrete cube results 24
4.3 Ultimate loads at failure 25
4.4 Stiffness (k) 29
4.5 Modes of failure 30
4.6 Discussion 33
CHAPTER 5 CONCLUSIONS AND RECOMMENDATIONS 41
5.1 Conclusions 41
5.2 Recommendations for future research 43
REFERENCES 44
APPENDIX A 46
ix
LIST OF TABLES
TABLE NO. TITLE PAGE
2.1 Various expressions for kl [7]. 12
3.1 40 MPa concrete design mix. 19
3.2 Cylindrical concrete sample properties. 20
4.1 Test results on 40 MPa concrete. 25
4.2 Table depicts peak loads (kN) and axial compressions
(mm) at failure and failure modes.
33
4.3 Recommended values for parameters kl, kg and ks [7]. 35
4.4 The actual and calculated load capacities of wrapped
samples compared.
36
x
LIST OF FIGURES
FIGURE NO. TITLE PAGE
1.1 Schmidt Rebound Hammer Testing being carried out
on the 1000 mm diameter bored pile.
2
1.2 Concrete cores taken from the 1000 mm diameter
“under-strength” bored pile being tested.
2
1.3 Strengthening of an RC column by enlarging its cross
sectional area.
3
1.4 Two new columns are introduced in order to reduce
the stresses experienced by the under-strength column
C/2.
4
1.5 Retrofitting of under-strength bridge column with a
steel jacket.
5
1.6 Under-strength concrete column in a building wrapped
with carbon fibre reinforced polymer (CFRP) sheets.
6
1.7 Retrofitting of a concrete bridge pier with glass fibre
reinforced polymer (GFRP) sheets.
6
1.8 Axial load enhancement for a rectangular RC column
achieved by CFRP wrapping.
8
2.1 Unconfined circular column experiences lateral stress
fl when vertical load is applied.
9
2.2 FRP confined circular column. 10
2.3 Free-body diagram of circular column confined by an
FRP jacket.
10
3.1 Dimensions of sample type A and sample type B. 15
3.2 The direction of fabric wrapping on the cylindrical
sample in order to enable confinement of concrete.
16
xi
3.3 The CFRP sheet is lapped at a length of 100 mm in
order to prevent debonding.
16
3.4 Sample preparation and wrapping with CFRP sheet. 17
3.5 Flow chart for the experimental procedure. 18
3.6 Compressive testing of 150 mm concrete cubes. 19
3.7 Cross-sectional dimensions and reinforcement details
of circular concrete samples.
21
3.8 Reinforcement cage for the concrete samples used in
this study.
21
3.9 Plan view of the reinforcement cage used in this study. 22
3.10 SikaWrap-200C woven carbon fibre fabric (width 600
mm) for structural strengthening.
22
3.11 A wrapped sample being tested under the application
of uniaxial compressive loading.
23
4.1 Load-compression curve for samples A1 and A2. 26
4.2 Load-compression curve for samples B1 and B2. 27
4.3 Load increase for all samples tested. 28
4.4 Load-compression curve for samples A2 and B2. 28
4.5 Load-deflection behaviour of wrapped samples A2 and
B2.
29
4.6 Load-deflection behaviour of unwrapped samples A1
and B1.
30
4.7 Compressive failure of the unwrapped concrete
sample.
31
4.8 Mode of failure of (a) wrapped and (b) unwrapped
samples.
32
4.9 Peak failure loads for wrapped samples A2 and B2. 37
4.10 Bits of concrete stuck to the CFRP fabric. 38
4.11 Typical stress-strain behaviour of steel and FRP
materials [12].
40
xii
LIST OF SYMBOLS
Ac - cross sectional area of concrete
Ag - gross cross-sectional area of concrete
Asc - cross-sectional area of longitudinal steel
Ast - cross-sectional area of longitudinal steel
D or d - diameter of circular concrete column
Ec - modulus of elasticity of concrete
EFRP - modulus of elasticity of FRP
f’c - compressive strength of the unconfined concrete, measured by
testing 150 mm x 300 mm cylinders according to ASTM C39
f’cc - strength of concrete due to the confinement effect of the FRP
f’cc2:1 - confined concrete strength of a concrete specimen with L/D = 2
f’co - unconfined strength of concrete
fcu - characteristic strength of concrete
fFRP - ultimate tensile strength of the FRP
fl - confinement pressure exerted by FRP
fy - characteristic strength of reinforcement
k - Stiffness = P/Δ
kg - gap factor
k1 - confinement effectiveness coefficient
ks - shape factor
L - length of column
le - effective length of column
M - bending moment
Nu - ultimate axial load capacity of column
P - axial compressive load
Pn - axial load capacity of column
xiii
t or tFRP - thickness of FRP or total thickness for multiple plies
γc - partial safety factor for concrete
γfrp - partial factor for FRP tensile strength
γs - partial safety factor for steel reinforcement
Δ - axial deformation (shortening)
λ - column slenderness ratio (L/D)
vc - Poisson ratio of concrete
ψf - reduction factor for concrete
xiv
LIST OF ABBREVIATIONS
AFRP Aramid Fibre Reinforced Polymer.
CFRP Carbon Fibre Reinforced Polymer.
EBR Externally Bonded Reinforcement.
FRP Fibre Reinforced Polymer.
GFRP Glass Fibre Reinforced Polymer.
HPC High Performance Concrete
HSC High Strength Concrete
RC Reinforced Concrete.
xv
LIST OF APPENDICES
APPENDIX TITLE PAGE
A Axial Load Estimation for CFRP-wrapped Samples 46
CHAPTER 1
INTRODUCTION
1.0 Introduction
In a number of cases, the structural strength of reinforced concrete members
have been found to be less than the design strength, therefore, forcing the structural
engineer to strengthen these members in order to cater the dead, super-dead and
superimposed loads to which these structural members are subjected throughout their
service life.
In the case of under-strength reinforced concrete columns, a few options are
available to the structural engineer, among them:
(a) complete demolition and re-construction – this is the most radical
alternative whereby strengthening of the member in question is either not
feasible structurally or economically, or the structural engineer is unwilling to
take any risks pertaining to the dubious strength of the said member.
For example, a 1000 mm diameter bored pile for a bridge foundation as
shown in Figure 1.1 was found to be of under-strength concrete. The
consulting engineer stipulated that the actual strength of the concrete has to
2
be established by Schmidt Rebound Hammer Testing as shown in Figure 1.1.
Core samples were also taken and tested as shown in Figure 1.2.
Figure 1.1: Schimdt Rebound Hammer Testing being carried out on the
1000 mm diameter bored pile.
Figure 1.2: Concrete cores taken from the 1000 mm diameter “under-strength” bored pile being tested.
3
The consulting engineer stated that if the in-situ concrete strength determined
from rebound hammer testing and core tests was satisfactory, then the bored pile
in question can be accepted as being of sound quality. On the contrary, if the
concrete strength is determined to be lower than the design strength, then the
bored pile should be abandoned and a replacement pile had to be constructed.
(b) enlargement – structurally this is the simplest and most obvious solution
to strengthen under-strength columns as shown in Figure 1.3.
Figure 1.3: Strengthening of an RC column by enlarging its cross
sectional area.
However, this method has a few drawbacks. First of all, expensive rentable
floor area is lost when the dimensions of columns are enlarged. For example,
when a 450 mm-square column is enlarged to 600 mm x 600 mm,
approximately 2 square feet of floor space is lost. This leads to a loss in
revenue from floor rental.
From project budgeting point of view, enlargement will incur additional
material and labour costs.
New concrete cast against
under-strength column
4
(c) stress reduction – this can be achieved by the addition of extra columns,
resulting in load distribution away from the under-strength column to the
newly added columns as shown in Figure 1.4. Once again, this solution is
both expensive and ruins the architectural functionality of the floor space.
Figure 1.4: Two new columns are introduced in order to reduce the
stresses experienced by the under-strength column C/2.
(d) installation of steel plates – this traditional method of strengthening
reinforced concrete structural elements as shown in Figure 1.5 is now deemed
both expensive and inefficient as the strength enhancement achieved per
kilogramme of steel used is rather low.
5
Figure 1.5: Retrofitting of under-strength bridge column with a steel
jacket.
This method also involves the lugging of thick steel plates to the construction
site. Installation is difficult due to the weight of these plates which would
have to be mechanically attached to the under-strength columns using bolts
and nuts. Surface treatment of these plates is absolutely necessary for
corrosion and fire protection, thus incurring further costs to the contractor.
(e) wrapping with FRP sheets – currently this method as shown in Figures 1.6
and 1.7 is gaining popularity as it is a clean and hassle-free method of
strengthening structural concrete members. The confining effect of the FRP
sheets enhances the compressive strength of the concrete.
6
Figure 1.6: Under-strength concrete column in a building wrapped with
carbon fibre reinforced polymer (CFRP) sheets.
Figure 1.7: Retrofitting of a concrete bridge pier with glass fibre
reinforced polymer (GFRP) sheets.
7
This study seeks to investigate the behaviour of circular concrete columns
wrapped with CFRP fabric under the application of monotonic axial loading.
1.1 Objectives of the study
The objectives of the study are as follows:
i. To study the mode of failure of circular reinforced concrete columns
wrapped with carbon fibre reinforced polymer (CFRP) sheet.
ii. To study the increase in axial load capacity of CFRP-wrapped
columns as compared to unwrapped columns.
iii. To study the effects of column slenderness ratio, λ, on the axial
strength gain of CFRP-wrapped columns.
1.2 Scope of the study
This study is restricted to circular column specimens wrapped with a single
ply of CFRP sheet consisting of mid-strength carbon fibres under the application of
purely compressive loading. As no eccentricity is considered, no bending moment is
applied to the column specimens tested in the study. Normal concrete having a
characteristic 28-day cube strength of 40 MPa is used. Neither high-strength (HSC)
nor high-performance concrete (HPC) is considered. The slenderness ratios of the
concrete specimens are restricted to values of λ = 4 and λ = 8.
8
1.3 Case study
It was required to increase the load capacity of a 300 mm by 450 mm
rectangular RC column as shown in Figure 1.8 reinforced with 6 numbers of 20 mm
diameter steel bars with the characteristic yield strength of steel is 400 N/mm2. The
compressive 28-day cube strength of the concrete [1] was 22.4 MPa giving an
ultimate axial load carrying capacity of 1983 kN. By wrapping the column with four
plies of BBR carbon fibre sheet CFS 240 – 300 gm/m2, the ultimate load bearing
capacity of the column was increased by 21.5% to 2409 kN.
Figure 1.8: Axial load enhancement for a rectangular RC column achieved by CFRP wrapping.
REFERENCES
[1] “A Guide to the Design and Application of BBR FRP Strengthening Systems (2002)”, BBR Systems Ltd. Schwerzenbach, Switzerland.
[2] Karbhari, V.M. and Gao, Y. (1997) “Composite jacketed concrete under uniaxial compression – verification of simple design equations.” ASCE Journal of Materials in Civil Engineering, Vol. 9, No. 4.
[3] Toutanji, H.A. (1999) “Stress – strain characteristics of concrete columns externally confined with advanced fiber composite sheets.” ACI Materials Journal, Vol. 96, No. 3.
[4] Saafi, M., Toutanji, H.A. and Li, Z. (1999) “Behavior of concrete columns confined with fiber reinforced polymer tubes.” ACI Materials Journal, Vol. 96, No. 4.
[5] Miyuachi, K., Inoue, S., Kuroda, T. and Kobayashi, A. (1999) “Strengthening effects of concrete columns with carbon fiber sheet.” Transactions of The Japan Concrete Institute, Vol. 21.
[6] Samaan, M., Mirmiran, A. and Shahawy, M. (1998) “Model of concrete confined by fiber composite.” ASCE Journal of Structural Engineering, Vol. 124, No. 9.
[7] Teng, J.G., Chen, J.F., and Lam, L. (2002) “FRP-strengthened RC structures.” John Wiley & Sons, Ltd., West Essex, England.
[8] Mirmiran, A., Shahawy, M., Samaan, M. and El Echary, H. (1998) “Effect of column parameters on FRP-confined concrete.” ASCE Journal of Composites for Construction, Vol. 2, No. 4.
[9] Mander, J.B., Priestley, M.J.N. and Park, R. (1988) “Theoretical stress – strain model for confined concrete.” ASCE Journal of Structural Engineering, Vol. 114, No. 8.
45
[10] Saadatmanesh, H., Ehsani, M. R. and Li, M. W. (1994) “Strength and ductility of concrete columns externally reinforced with fiber composite straps.” ACI Structural Journal, V. 91, No. 4 July-August 1994.
[11] American Concrete Institute (ACI) (2002) “Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures.” ACI-440, ACI-440 Committee, Detroit.
[12] FIB Bulletin 14 Technical Report (2001) “Externally Bonded FRP Reinforcement for RC Structures.” International Federation of Structural Concrete, Lausanne.
[13] Spoelstra, M.R. and Monti, G. (1999) “FRP-confined concrete
model.” ASCE Journal of Composites for Construction, Vol. 3, No. 3. [14] “BS 8110-1:1997 - Structural use of concrete - Part 1: Code of
practice for design and construction (Incorporating Amendments Nos. 1, 2, 3 and 4).” British Standards Institution, London.
[15] “Product Information Edition 02/2008.” Sika Kimia Sdn. Bhd., Lot 689, Nilai Industrial Estate, 71800 Nilai, Negeri Sembilan, Malaysia.
[16] Razavi, M. (2009) “Strengthening of under-strength concrete using FRP fabric.” Master’s Thesis, Universiti Teknologi Malaysia, Johor Bahru, Malaysia.
[17] Aire, C., Gettu, R. and Casas, J.R. (2001) “Study of the compressive behavior of concrete confined by fiber reinforced composites - Composites in Construction (ISBN 90 2561 858 7).” Swets & Zeitlinger, Lisse, The Netherlands.
[18] Balaguru, P., Nanni, A. and Giancaspro, J. (2009) “FRP Composites for Reinforced and Prestressed Concrete Structures – A guide to fundamentals and design for repair and retrofit.” Taylor & Francis, New York.
[19] Elwell, D.J. and Fu, G. (1995) “Special Report 119 – Compression testing of concrete: cylinders vs. cubes.” Transportation Research and Development Bureau, Albany, New York.