Street Light 2
Transcript of Street Light 2
POLE PEDESTRIAN LIGHTING (E01) - TYPES
ALTERNATE FOR A B
7’-0”
NEW STEEL LAMP POLE
NEW STEEL LAMP POLE
(6) 7 1/4” DIA. GLOBE
(4) 9 1/2” DIA. GLOBE
(3) 13” DIA. GLOBE
(5) 7 1/4” DIA. GLOBE
(3) 9 1/2” DIA. GLOBE
(2) 13” DIA. GLOBE
(5) 7 1/4” DIA. GLOBE
(3) 9 1/2” DIA. GLOBE
(2) 13” DIA. GLOBE
LUMINAIRE
NEW STEELLAMP POLE
BRACKET & ARM
BRACKET & ARM
BRACKET & ARM
A
8’-0”
LUMINAIRE
13’-0”
30’-0”
20’-0”
8’-0”
7’-0”
13’-0”
30’-0”
20’-0”
8’-0”
7’-0”
13’-0”
20’-0”
8’-0”
5’-0”
5’-0”
1 ELEVATION - BASE BIDscale: AS NOTED
GENERAL NOTES
1 TOTAL LUMENS: APPROXIMATELY 14,000 LUMENS
2 TOTAL WATTAGE NOT TO EXCEED 1300 WATTS
3 NEW LIGHT POLES ARE INSTALLED ON EXISTING
FOUNDATIONS
4 NEW LAMP POLE: ASTM-A595 STEEL; F283 GALVANIZED
POWDER TOP COAT; FINAL COLOR TBD BY DESIGNER
5 LAMP POL BASE COVER TO BE SUPPLIED BY THE CITY
STAMP:STAMP:
4 7 6 1LEE SWAIN, P.E. | CITY ENGINEER
RICK VALTE, P.E. | PRINCIPAL CIVIL ENGINEER2 3 9 4
ZACH POLLARD, P.E. | CIVIL ENGINEER
E.04
24
4TH STREET PEDESTRIAN IMPROVEMENTS100% CONSTRUCTION DOCUMENTS AUGUST 31, 2015
selbert perkins design col laborat ive
432 Culver Boulevard, Playa Del Rey, CA 90293
T 310 822 5223 www.selbertperkins.com
PROPOSED PLAN - MATERIALS - LIGHTING / ELECTRICAL
Data sheet
Philips Lighting Rev. 20150604 3 Burlington Woods Drive Burlington, MA 01803 Copyright © 2015 Philips Lighting. All rights reserved Tel 888 385 5742 Specifications may change without notice. Fax 617 338 0454 www.colorkinetics.com
Vaya Tube, White & Mono (On-Off) Vaya Tube White & Mono is a reliable and cost effective direct view linear LED lighting fixture designed for exterior accent and contour lighting applications. The slim form factor and light weight allow for easy and flexible integration into façade cladding elements or structures. Up to 12m (40ft) linear runs can be connected per 24V power supply for crisp, static lighting effects.
Key Features
Uniform band of light in 180° viewing angle
Slim profile & light weight
Available in 4 CCTs: 2700K, 3000K, 4000K, 5000K
Available in 4 Mono Colors: Red, Green, Blue, Amber
3-Year Warranty
Product Data Width 47 mm (1.8in), including mounting bracket Height 66 mm (2.4in), including mounting bracket Length 300 mm (1 ft)
Mounting Front-serviceable surface mount brackets Source White or Mono Color (Red / Green / Blue / Amber)
Viewing Angle 180° 2700K Flux & Intensity 178 lm / 40 cd 5000K Flux & Intensity 215 lm / 48 cd
Lumen Maintenance White: 50,000 hrs L70 at 25ºC Mono: 50,000 hrs L50 at 25ºC
Lens Translucent Cover Lens Housing UV-stabilized polycarbonate, dark grey finish (RAL7043) Weight <0.5 kg (1lbs)
Connection Input and output connectors Control On-Off
Input Voltage 24V DC Power Consumption 3 W
Run-Length 46 fixtures Temperature Range -20ºC to 40ºC (-4ºF ~104ºF) start-up temperature
-40ºC to 40ºC (-40ºF ~104ºF) operating temperature Protection Rating IP66, Wet location listed, IK10
Certifications UL / cUL, FCC Class A, CE, CB, CQC, SAA, C-Tick Warranty 3 Years
Data sheet
Philips Lighting Rev. 20150604 3 Burlington Woods Drive Burlington, MA 01803 Copyright © 2015 Philips Lighting. All rights reserved Tel 888 385 5742 Specifications may change without notice. Fax 617 338 0454 www.colorkinetics.com
Vaya Tube, White & Mono (On-Off) Vaya Tube White & Mono is a reliable and cost effective direct view linear LED lighting fixture designed for exterior accent and contour lighting applications. The slim form factor and light weight allow for easy and flexible integration into façade cladding elements or structures. Up to 12m (40ft) linear runs can be connected per 24V power supply for crisp, static lighting effects.
Key Features
Uniform band of light in 180° viewing angle
Slim profile & light weight
Available in 4 CCTs: 2700K, 3000K, 4000K, 5000K
Available in 4 Mono Colors: Red, Green, Blue, Amber
3-Year Warranty
Product Data Width 47 mm (1.8in), including mounting bracket Height 66 mm (2.4in), including mounting bracket Length 300 mm (1 ft) 1200 mm (4 ft)
Mounting Front-serviceable surface mount brackets Source White or Mono Color (Red / Green / Blue / Amber)
Viewing Angle 180° 2700K Flux & Intensity 178 lm / 40 cd 750 lm / 170 cd 5000K Flux & Intensity 215 lm / 48 cd 900 lm / 200 cd
Lumen Maintenance White: 50,000 hrs L70 at 25ºC Mono: 50,000 hrs L50 at 25ºC
Lens Translucent Cover Lens Housing UV-stabilized polycarbonate, dark grey finish (RAL7043) Weight <0.5 kg (1lbs) < 1.0kg (2 lbs)
Connection Input and output connectors Control On-Off
Input Voltage 24V DC Power Consumption 3 W 12 W
Run-Length 46 fixtures 12 fixtures Temperature Range -20ºC to 40ºC (-4ºF ~104ºF) start-up temperature
-40ºC to 40ºC (-40ºF ~104ºF) operating temperature Protection Rating IP66, Wet location listed, IK10
Certifications UL / cUL, FCC Class A, CE, CB, CQC, SAA, C-Tick Warranty 3 Years
19'-0"
12'-0" 12'-0" 12'-0"23'-6" 6'-6"
2'-0"3'-0" 3'-0"2'-6"
14'-0" 12'-0" 12'-0" 31'-5"
4'-7" 4'-0" 6'-4"
12'-0" 21'-10"12'-0"12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 12'-0"39'-6" 8'-6" 9'-8" 12'-0" 14'-7"
1'-5" 5'-1"
37'-5" 9'-6" 11'-10" 6'-0"
5'-11"
14'0"
7'-9" 13'-6"
6'-11"
29'-4"
3'-11"8'-51/2"
12'-8" 24'-6"
2'-1"(TYP)
0' 20'10' 40' 60' 80' 100'
NN
LEGEND
X
DETAIL NOTES
NOTATIONS
X
CONSTRUCTION NOTES
ELECTRICAL
NEW VEHICLE / PEDESTRIAN LIGHTING - TYPE A(2) QUANTITY
NEW PEDESTRIAN LIGHTING - TYPE B(4) QUANTITY
PAVEMENT PEDESTRIAN LIGHTING(11) QUANTITY
APPROXIMATE LOCATION OFEXISTING 2” CONDUIT WITH EXISTING CONDUCTORS
WIRING RUN UNDER FLOOR, OR UNDERGROUND
MATERIALSTREE PIT WITH GRATEAND PAVEMENT PEDESTRIANLIGHTING
E
STLT
STLT
E
E
E
E E E E E E E E E E E E E E E
TO PEDESTAL "MPE"ON SW CORNER OF4TH AND BROADWAY.APPROXIMATE LOCATION OF CONDUIT. FIELD VERIFYPRIOR TO BID.
BR
OA
DW
AY
BENCH
1 PROPOSED PLAN - LIGHTING / ELECTRICALscale: 1"=20'-0"
2 DETAIL PLAN - PAVEMENT PEDESTRIAN LIGHTINGscale: 1/2"=1'-0"
4 MINIMUM COVER REQUIREMENTSscale: AS NOTED
3 PAVEMENT PEDESTRIAN LIGHTINGNO SCALE
5 DETAIL PAVEMENT PEDESTRIAN LIGHTINGNO SCALE
3 3 3 3 3 3 3 3 3 3 31 12 2 22
MA
TCH
LINE
E.03/01
CURB SIDE
EXISTING UNDERGROUND 2” CONDUIT. PROTECT AND REUSE.
EXISTING UNDERGROUND TREE LIGHTING JUNCTION BOX. PROTECT AND REUSE.
(12) 1’ SECTIONS OF PHILLIPS VAYA TUBE 5000K MOUNTED TO LOWER METAL FRAME FROM TREE GRATE BY TREE GRATE MANUFACTURER. CONTRACTOR TO CONNECT EXISTING POWER TO NEW FIXTURES THROUGH NEW POWER PACK PROVIDED WITH TREE GRATE.
1/2” LIQUIDTITE FLEXIBLE WET LOCATION CONDUIT. ROUTE PREASSEMBLED FIXTURE CABLE THROUGH CONDUIT TO POWER PACK AND CONNECT.
PHILLIPS LIGHTING POWER PACK #309-000014-00, ADJUST LOCATION TO FIELD CONDITIONS AND LENGTH OF FIXTURE CABLE.
1/2” LIQUIDTITE FLEXIBLE WET LOCATION CONDUIT WITH 3#1 CONDUCTORS FROM FIXTURE POWER PACK TO EXISTING JUNCTION BOX. PULL NEW CONDUCTORS THROUGH EXISTING CONDUIT TO EXISTING METER.
15,121 VAVAVA
A
EXISTING LOADADDED LOAD (CIRCUIT 12)TOTAL@ 240V, 1P
FROM SHEET E2.4 DRAWING 6548 - 2009. ASBUILT OF 4TH STREET IMPROVEMENTS.
NEW LIGHTS ON EXISTING CIRCUITSNOT TO EXCEED EXISTING LOAD.• Uniform band of light in 180° viewing angle
• Slim profile & light weight
• CCT: 5000K
• White
• 3-Year Warranty
CONSTRUCTION NOTES
1 UTILIZE EXISTING CIRCUIT (METER “MPE” - CIRCUIT 8.)
NEW FIXTURE NOT TO EXCEED 300W.
2 UTILIZE EXISTING CIRCUIT (METER “MPE” - CIRCUIT 8.)
NEW FIXTURE NOT TO EXCEED 150W.
3 UTILIZE EXISTING CIRCUIT AND PULL NEW 120V CIRCUIT
TO METER “MPE” - CIRCUIT 12. PROVIDE 3#10 CONDUCTORS
TO NEAREST PULLBOX AND 2#2 & 1#6G FROM NEAREST
PULLBOX TO METER “MPE”. INSTALL NEW 30A/1P 120V
BREAKER IN “MPE”. INSTALL NEW DAYLIGHT SENSOR ON
PEDESTAL AND ROUTE CIRCUIT 12 THROUGH SENSOR.
W EACH.
GENERAL NOTES
1 PROTECT ALL SURFACES AND SUBSURFACE UTILITIES
TO REMAIN, INCLUDING ALL EXISTING IRRIGATION AND
ELECTRICAL CONNECTIONS.
2 MAINTAIN AND PROTECT ALL EXISTING PAVEMENTS TO
REMAIN.
3 COORDINATE ALL WORK WITH APPROPRIATE CITY AGENCIES
AND TRANSIT AUTHORITIES.
4 PLANT BEDS TO BE EXPANDED AND PREPARED FOR NEW
TREES AND GROUNDCOVERS.
5 ALL EXISTING PEDESTRIAN LIGHT POLES TO BE REMOVED,
PROTECTED, AND REPLACED WITH NEW PEDESTRIAN LIGHT
POLES ON EXISTING FOOTINGS.
6 PROTECT IN PLACE ALL UNDERGROUND ELECTRICAL
CONDUIT AND WIRE DURING DEMOLITION. CONDUIT AND
WIRE TO BE REUSED.
STAMP:STAMP:
4 7 6 1LEE SWAIN, P.E. | PRINCIPAL CIVIL ENGINEER
RICK VALTE, P.E. | PROJECT DIRECTOR
ZACH POLLARD, P.E. | CIVIL ENGINEER
E .02
SANTA MONICA 4TH STREET100% CONSTRUCTION DOCUMENTS AUGUST 14, 2015
selbert perkins design col laborat ive
432 Culver Boulevard, Playa Del Rey, CA 90293
T 310 822 5223 www.selbertperkins.com
P2S Engineer ing, Inc
5000 East Spr ing Street, 8th Floor
Long Beach, CA 90815
T 562 497 2999 www.p2seng.com
SELBERT PERKINS DESIGNS
TURNKEY LIGHTING SOLUTIONS LLC
SPD / CD
ELECTRIC
STAMP
648
15, 76965.70
0
36
7. ALL NEW LIGHTING TO HAVE PHOTOMETRIC LAYOUTS PROVIDED BY MANUFACTURER THAT COMPLY WITH CITY STANDARDS.
EFORPDE
RE
TSI
GE
R RE
ENI
GNE
LANOISS
C A L I F ORN
I AST
A T EO F
ST
E V E N C . MUS SE
R
E L E C T R I C A L
No. E198178/17/2015
P2S Engineer ing, Inc
5000 East Spr ing Street, 8th Floor
Long Beach, CA 90815
T 562 497 2999 www.p2seng.com
19