Still Heating Technologies and
Emulation of Direct Fired
Character
James Ludford-Brooks
Briggs of Burton
![Page 2: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/2.jpg)
Talk Outline• Introduction
– Still heating objectives
• Overview of Still Heating Technologies
– Direct Fired
– Internally Heated
– Externally Heated
• Emulation of Direct Fired Character
– Can the Pot Still Heating Method Influence Spirit Character?
– Investigation using Novel Thermal Fluid (Oil) Heating Technology
![Page 3: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/3.jpg)
Still Heating Objectives
• Heat the Still to boiling
• Maintain a consistent evaporation rate from
Batch start to the end
• Minimise fouling & Cleaning
• Controllable, reliable & safe.
• Minimise energy usage / Carbon footprint
![Page 4: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/4.jpg)
Direct Fired System• Natural Gas Fired (typically) –
flame temp 1200°C
• Flue Exit Temp 600°C
• Low Copper Surface Area > 200°C (~0.8 m2/m3)
• 9.2 kWh/litre pure alcohol (lpa)
• Preheated combustion air ~ 15% fuel saving
• Rummager – removal of fouling material produced continuously
• Refractory Lined ‘Hot Box’
![Page 5: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/5.jpg)
Internal Coil / Pans• Steam Most Common
– Potential for Thermal Fluid
• Stainless Steel Coil / Pan
• Energy– Low Heating Surface Area
– 135 - 152°C (0.8 m2/m3)
– Typically Isothermal Heating
– 7.2 kWh / litre pure alcohol (lpa)
• Cleaning– Fouling Removed by
Cleaning In Place (CIP)
![Page 6: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/6.jpg)
• Wash does NOT boil in heat
exchanger
• Min Height at End of Distillation is
critical, Can dictate minimum
Recirculation rate
• Check Net Positive Suction Head
(NPSH)
• Heating Surface 135-152°C (1.0
m2/m3)
• TVR/HTHP High Heating Surface
Area 95-107°C (~1.6 m2/m3)
External Heater (Plate or Shell & Tube)
![Page 7: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/7.jpg)
Pumped Recirculation - OPEX• Recirculation pump operational cost often overlooked
– ~ 0.3 -0.8 kWe/m3
– £2,400 – £5,900 cost p.a (per pump at 11p/kWh)
• Recirculation rate dependent on steam pressure and temp.
raise per pass.
– 6 - 15+ contents/hr.
• Thermosyphon during distillation could eliminate this cost
• Thermosyphon commonly used in brewing industry
• Vapour Bubbles Beneficial
– Volatile Stripping
• improved cogener recovery?
![Page 8: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/8.jpg)
Thermosyphon Recirculation
• Principle:
– Density difference between Single Phase and Two Phase system
– Creates Driving Force for the Thermosyphon recirculation
Two Phase Flow
( Liquid & Vapour )
Single Phase
Flow (Liquid)
![Page 9: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/9.jpg)
External Heater – Return above max level
![Page 10: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/10.jpg)
Thermal Vapour Recompression
(TVR) Still
![Page 11: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/11.jpg)
TVR Features
• 40% Reduction in Batch
Distillation Steam Usage for
Scotch Whisky Wash Distillation
~ 5.5 kWh/ l alc
• Low Steam Pressure, coupled
with good control and pumped
condensate systems yield
consistent batch times and low
fouling levels
• Opex (Pump circulation)
• Generally complex operation
(Automation & control)
• Condenser Life Reduced
compared to traditional
Pros Cons
![Page 12: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/12.jpg)
TVR Steam Injector Nozzle
• Motive steam supplied from boiler
• A valve controls / throttles motive steam entering steam injector nozzle, steam required depends on compression ratio.
• Motive steam entrains the recovered steam
• Discharge steam heats the still and must be at sufficient pressure to push the condensate to drain/receiver
Compression Ratio (Start/End) : 2.4 /1.4
Expansion Ratio (Start/End) : 16 / 9
Motive steam
8 bar A
Discharge steam
(Total system
steam)
1.2 – 1.3 bar A
Recovered steam
0.5 – 0.9 bar A
65% open (typical)∆H
![Page 13: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/13.jpg)
TVR Operation – Variable steam supply
Operation
• Only possible with pumped condensate return
• Steam can condense at less than atmospheric pressure in the HX
• Motive steam is reduced as recovered steam increases
Motive steam
Discharge steam
(Total steam) Recovered steam
Variable ∆H
Compression Ratio (Start/End) : 1.8 /1.3
Expansion Ratio (Start/End) : 16 / 9
![Page 14: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/14.jpg)
Distillation steam recovery
• Fixed motive steam– 33 to 63 %
– Avg. = 48 %
• Variable motive steam– 50 to 63 %
– Avg. = 56 %
Theoretically:
![Page 15: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/15.jpg)
High Temperature Heat Pump
(HTHP) Still
![Page 16: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/16.jpg)
HTHP Features
• >85% Reduction in Batch
Distillation Steam Usage for
Scotch Whisky Wash Distillation
– 3.3 kWh / litre alc
• Low Steam Pressure, coupled
with good control and pumped
condensate systems yield
consistent batch times and low
fouling levels
• Reliance on Fossil Fuel
Significantly reduced
• No examples in existence
– Briggs Auchroisk-1985
• Generally complicated
operation
– Automation & control
• Condenser Life Reduced
compared to traditional
• Payback Relative to Boiler
Fuel and Electricity Price
• Opex (Pump circulation)
Pros Cons
![Page 17: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/17.jpg)
Emulation of Direct Fired Character
• Bently Heritage Distillery, Minden,
Nevada
– build a modern, safe and efficient still
house
– recreate the rich, delicate character
found from direct fired stills
![Page 18: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/18.jpg)
Distillery Wash
Character obtained from Still Influenced by
• Raw Materials & Yeast
• Wort Separation Method
• Degree/length of Fermentation
• Heating Method & Reflux
![Page 19: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/19.jpg)
Maillard Reaction Temperatures
Flavour + colour =
• Water + (Temperature / Time) + (Amino acids + Sugar)
Still heating
technologyTVR & HTHP Steam Thermal oil Direct Fired
Operating
temperature (°C)107 135 185 >200
![Page 20: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/20.jpg)
Wash Turbidity
0
200
400
600
800
1000
1200
0 20 40 60 80 100 120 140 160 180
EB
C
Time (mins)
Distillery A Distillery B
Distillery C Distillery D
![Page 21: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/21.jpg)
Furfural level – Effect of Higher
Temperatures
0
200
400
600
800
1000
1200
1400
1600
Start Boil End Boil
Furf
ura
l
Brewhouse Trial
• 830 hl 6.5% / h x 70
min boil:• Internal Heater
– High Temperature Surface
– ~ 0.8 m2/m3
• High Surface Area Heater
Low Temperature Surface– 2.2 m2/m3
![Page 22: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/22.jpg)
External Thermal Oil Heater• Thermal Oil Heating - 200°C, low pressure
• Control By Variable Area (Unlike Steam,
Which is Variable Pressure/Temperature)
q= 𝐔.𝐀. ∆𝐓q = Heat Transfer (W) [Rate of heat energy
transfer per unit time]
U = Overall Heat Transfer Coefficient
(W/m².°C)
A = Heat Transfer Surface Area (m²)
∆T = Temperature Difference (°C) [Driving
force]
![Page 23: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/23.jpg)
External Thermal Oil Heater
![Page 24: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/24.jpg)
External ThermalOil Heater• Forced Circulation - reduce Fouling,
no boil at heat transfer surface
• Oil Recirculation maintained at desired Temp (145 – 185 °C)
• Split Range Control of HX Surface Area, lower valve (1) opens first, if duty not achieved, valve (2) opens
• Progressive fouling of heat exchanger Area ie Area increased as Heat exchanger fouls.
• Film boil likely to limit max temp of thermal oil in practise
![Page 25: Still Heating Technologies and Emulation of Direct Fired ...](https://reader034.fdocuments.in/reader034/viewer/2022042910/626a39d6bdb0412d094929db/html5/thumbnails/25.jpg)
Summary
• Method of Still heating is an
important choice
• Flexible equipment can allow the
distiller to select for specific
characteristics