Stepan Formulation 1127
-
Upload
adbuo-mahgh -
Category
Documents
-
view
265 -
download
3
description
Transcript of Stepan Formulation 1127
-
FFoorrmmuullaattiioonnName FOAMING ALKALINE BATHROOM CLEANERNo. 1127Description When dispensed via a foamer-trigger nozzle, this cleaner effectively removes bathroom grime
by providing a thick foam that clings to bathroom surfaces.Formulation INGREDIENTS:
Deionized WaterSodium CarbonateBIO-SOFT EC-600 AMMONYX LO Special Dowanol PnB (Dow) Propylene Glycol n-Butyl EtherEnviomet EDDS (Innospec) [S,S]-Ethylenediaminedisuccinic acid
% by Weight
86.02.01.09.01.01.0
Functionality
DiluentpH AdjusterEmulsifierFoaming and Cleansing AgentSolventChelating Agent
Total___________
100.0
Procedure 1. Charge Water and blend in Sodium Carbonate and AMMONYX LO Special.2. With good agitation, slowly blend in BIO-SOFT EC-600.3. Mix until homogenous.4. Blend in Enviomet EDDS and Dowanol PnB.
Physical Properties
AppearancepH, as isViscosity, cps
Clear liquid10.5Water thin
Storage/ Stability
Freeze/Thaw, 3 cycles4 weeks at 50C4 weeks at 25C4 weeks at 4C
PassStableStableStable
Instructions for Use
Spray on soiled surface and allow foam to penetrate. Wipe surface with wet sponge or cloth. Rinse with water.
External Comment Marketing Notes: BCI = 82. Total Biorenewable Carbon Index (BCI) was calculated only for the
Stepan surfactants used in this formulation. For further information on Stepan's BCI, visit www.stepan.com.
RegisteredTrademarks of Stepan Company
AMMONYX BIO-SOFT
For Additional Assistance
For applications or product handling assistance, call our Technical Service Department at 1-800-745-7837 (U.S.) or 011-334-76-505-100 (Europe).For ordering assistance, call our Account Service Department at 1-800-457-7673.Nothing contained herein grants or extends a license, express or implied, in connection with patents, issued or pending, of the manufacturer or others. The information contained herein is based on the manufacturer's own study
-
and the works of others. The manufacturer makes no warranties, expressed or implied, as to the accuracy, completeness, or adequacy of the information contained herein. The manufacturer shall not be liable (regardless of fault) to the vendee's employees, or anyone for any direct, special or consequential damages arising out of or in connection with the accuracy, completeness, adequacy or furnishing of such information.
Stepan Stepan CompanyNorthfield, Illinois 60093Telephone (847) 446-7500
Revision Date: 11/02/2012 Publication Date: 01/26/2010 2012, Stepan Company. All rights reserved.