Bead of sealant or expandable foam under track, then fasten with
anchor bolts, wedge anchors or wedge bolts (size and spacing per
plans)
Must be plumb in both directions, attach to base with ¾” SMS all sides, then corner screws as follows ………………….
Butt corner with 18 ga. channel attached with #10 x ¾” SMS on first panel then thru screw with SIPLD screws with washer. Attach all panels to base track with #10 x ¾” SMS
with every 3 panels run add top channel and wind brace as required, at this time only attach the pitched wall cap on exterior side with ¾” SMS , leaving interior side loose
Attach all walls to base and top
with ¾” SMS screws
Ridge Beams are field assembled with 2 vertical steel “C” members and a 18 ga. Track top and bottom attached with ¾” SMS per plans
Hangers can be purchased
from Simpson or fabricated
with 18 ga. angle
The interior surface of the wall and roof panel is typically furred out with 1 1/2" furring channels to promote conventional surface mounted installation of wiring and plumbing
Ductwork can be placed in dropped ceiling areas
Typically, plumbing is installed in interior walls and floors, but not in exterior walls. Where exterior wall vent pipes are necessary, chases can be formed in the foam cores or the wall framed out
Installing island vents or loop vents is also a common practice
#8 Polished stainless steel structural panels
Heavy Missile Impact Testing surpassed the requirements for all required structures as per the State of Florida Impact Requirements for Educational Facilities SS-TD-12-99 and ASTM E-1886 Wind Cycling and ASTM E-1996 Impact by Windborne Debris in Hurricanes including water resistance AFTER heavy missile impact and hurricane wind cycling
SSTD-1299 Non Porous Impact Protective Systems “State of Florida requirements for Educational Facilities” Chapter 5, section 5.4 Paragraph (d) Structural Missile Impact Criteria (Heavy Impact Missile at 50 feet Per Second)
Florida Building Commission Approval Listing for both Wall and Roof Assemblies (FL-6787 Walls and FL-6751 Roof)
ASTM E-1886 - 02 “Standard Test for Curtain Walls: Large Missile Impact and Exposed to Cyclic Pressure Differentials” (+/-) through 4500 cycles of each positive and negative pressure
ASTM E-1996 – 02 “Standard Specification for Curtain Walls Impacted by Windborne Debris in Hurricanes”
ASTM E-72 “Vacuum Chamber Structural Load Tests” Shear Modulus of Panel Core, Shear Strength of the Panel Core, Bending Strength, Connection Strength
ASTM-1592 & UL 580 “Standard Test Method for Steel/Metal Roof systems by Uniform Static Air Pressure Difference
UBC-26-3 and UL-1715 Room Fire Test Standards ASTM E-119-00a “Fire Test of Building Construction & Materials” Test
Conditions also described by Testing Standards UBC-7-1/1997, UBC 263 a and the NFPA 251 (National Fire Protection Association) for 1 Hour Fire Rated Load Bearing Wall Assemblies at 1650 LBS per lineal foot of wall
ASTM E-108 “Standard Test Methods for Fire Tests of Structural Roof Coverings” Intermittent Flame Test, Spread of Flame Test, Burning Brand Test, Rain Test, and Weathering
Class B Roof Assembly Rating at 5/12 Pitch ASTM 1592 Fastener and Connection
Strength of Roof Assemblies UL, ASTM, ICC/ICBO, BOCA, NBC, RBC,
SBCCI Certified EPS Insulation Cores International Steel Specifications and
Approvals Certified Lamination Adhesive
Extreme Fire Testing has been completed and certified on the SIP panel products and systems to exceed the building code having jurisdiction and all required Engineering