FEATURES FABPRO POLYMERS’ OMEGA™ II Steel Reinforcing Fiber is a low carbon, cut sheet, steel fiber. This industry proven fiber provides a reinforcement system that addresses restrained shrinkage in concrete slabs. The OMEGA™ II Steel Fibers are uniformly distributed throughout the concrete to assure the owner, contractor and engineer excellent crack control. OMEGA™ II Steel Reinforcing Fiber can significantly enhance direct tensile strength and eliminate WWM and rebar in residential, commercial and industrial applications. OMEGA™ II meets the requirements of ATSM A820/A820M, Type II “Standard Specification for Steel Fibers for Fiber-Reinforced Concrete” and is also approved for use in composite metal deck systems by the Steel Deck Institute. BENEFITS Versus rebar and WWM, OMEGA™ II Fibers: Are always positioned properly when mixed according to ASTM C94/C94M. Save time and money. Improve impact and abrasion resistance. Enhance durability and toughness. Eliminate the on-the-job safety concerns associated with using WWM and rebar. Provide improved crack control. PERFORMANCE CHARACTERISTICS Specific Gravity 7.86 Melting Point 2760˚F (1516˚C) Ignition Point 1500°F (816°C) Absorption Nil Tensile Strength 60 - 120 ksi (414 - 828 MPa) Fiber Length 1.0” (25mm) Aspect Ratio 43 Fiber Count 8,000 fibers/lb (0.45 kg) FABPRO POLYMERS' OMEGA™ II Steel Reinforcing Fiber DESCRIPTION The carbon steel fibers in OMEGA™ II meet the requirements of ASTM A820/A820M, Type II “Standard Specification for Steel Fibers for Fiber-Reinforced Concrete” and are approved for use in composite metal deck systems by the Steel Deck Institute. APPLICATIONS Recommended for use in: Any SOG application, to increase impact and shatter resistance Composite metal deck systems Driveways & loading areas, to increase fatigue strength Pavement, parking lots and overlays Applications where controlling drying shrinkage & temperature cracks are important Shotcrete Extending joints in slab-on- ground floors

Transcript of Steel Reinforcing Fiber - FabPro...FABPRO POLYMERS’ OMEGA™ II Steel Reinforcing Fiber is a low...

Page 1: Steel Reinforcing Fiber - FabPro...FABPRO POLYMERS’ OMEGA™ II Steel Reinforcing Fiber is a low carbon, cut sheet, steel fiber. This industry proven fiber provides a reinforcement

FEATURES FABPROPOLYMERS’OMEGA™IISteelReinforcingFiberisalowcarbon,cutsheet,steelfiber.Thisindustryprovenfiberprovidesareinforcementsystemthataddressesrestrainedshrinkageinconcreteslabs.TheOMEGA™IISteelFibersareuniformlydistributedthroughouttheconcretetoassuretheowner,contractorandengineerexcellentcrackcontrol.

OMEGA™IISteelReinforcingFibercansignificantlyenhancedirecttensilestrengthandeliminateWWMandrebarinresidential,commercialandindustrialapplications.OMEGA™IImeetstherequirementsofATSMA820/A820M,TypeII“StandardSpecificationforSteelFibersforFiber-ReinforcedConcrete”andisalsoapprovedforuseincompositemetaldecksystemsbytheSteelDeckInstitute.

BENEFITS VersusrebarandWWM,OMEGA™IIFibers:

• ArealwayspositionedproperlywhenmixedaccordingtoASTMC94/C94M.• Savetimeandmoney.• Improveimpactandabrasionresistance.• Enhancedurabilityandtoughness.• Eliminatetheon-the-jobsafetyconcernsassociatedwithusingWWMand

rebar.• Provideimprovedcrackcontrol.

PERFORMANCE CHARACTERISTICS

Specific Gravity 7.86 Melting Point 2760˚F (1516˚C) Ignition Point 1500°F (816°C) Absorption Nil Tensile Strength 60 - 120 ksi (414 - 828 MPa) Fiber Length 1.0” (25mm) Aspect Ratio 43 Fiber Count 8,000 fibers/lb (0.45 kg)

FABPRO POLYMERS'

OMEGA™ II Steel Reinforcing Fiber

DESCRIPTION

ThecarbonsteelfibersinOMEGA™IImeettherequirementsofASTMA820/A820M,TypeII“StandardSpecificationforSteelFibersforFiber-ReinforcedConcrete”andareapprovedforuseincompositemetaldecksystemsbytheSteelDeckInstitute.

APPLICATIONS

Recommendedforusein:

• AnySOGapplication,toincreaseimpactandshatterresistance

• Compositemetaldecksystems• Driveways&loadingareas,to

increasefatiguestrength• Pavement,parkinglotsand

overlays• Applicationswherecontrolling

dryingshrinkage&temperaturecracksareimportant

• Shotcrete• Extendingjointsinslab-on-

groundfloors

Page 2: Steel Reinforcing Fiber - FabPro...FABPRO POLYMERS’ OMEGA™ II Steel Reinforcing Fiber is a low carbon, cut sheet, steel fiber. This industry proven fiber provides a reinforcement

GUIDELINES FOR USE Dosage:OMEGA™IIFibersaretypicallyaddedatadosagerateof15 to 25 lb/yd³ (8.9 kg/m³ to 14.8 kg/m³) in standard jointedfloors based on ACI 360 design guidelines. Dosages up to 65lb/yd³(38.6kg/m³)canbeused inextendedjointedfloors.Forextended joint floors beyond the standard ACI 360 designguidelinesforslabsonsupportedgroundconstruction,FABPROrecommendsconsultingourdesignengineeranddesignprogramforproperdosagerates.

Mixing,Placing,andFinishing:OMEGA™IIFibersarepackagedin50 lb/yd³(29.7kg/m³)boxesandcanbe introducedintothetruck before, during or after batching. Please follow propermixingproceduresasspecifiedinASTMC94/C94M.

OMEGA™IIFiberscanbepumpedandplacedusingconventionalequipment.Hand screedscanbeused, butvibratoryand laserscreedsarerecommendedtoprovideaddedcompactionandtohelpburythefibersbelowthesurface.

Normalfinishingequipmentandtechniquescanbeusedwhenfinishing. Troweling blades should be kept flat for as long aspossibletoinsureafiberfreesurface.

Standard practices detailed in ACI 544-3R for placing, finishingand curing fiber concrete should be followed when usingOMEGA™IIFibers.ENGINEERING SPECIFICATIONS OMEGA™IIFibersareforthecontrolofcrackingduetodryingshrinkage,thermalexpansionandcontraction,andtoaddressimpactandshatterresistance.OMEGA™IIFibersfromFABPROPOLYMERScomplywithapplicablebuildingcodesandASTMC1116/C1116MSection4.1.3,TypeI,andareapprovedforuseincompositemetaldecksystemsbytheSteelDeckInstitute.

OMEGA™IIshouldbespecifiedforuseinconcreteslabs:

q Tolimitthewidthofcracksthatoccurbetweenjointsq Toenhanceaggregateinterlockatthejointsq Toimproveimpactresistanceq Toprovidesuperiorcrackcontrolq Tocontroldryingshrinkagecrackingandtemperature

cracking

FABPRO’s OMEGA™ II Fibers should not be used to replacestructural, load-bearing reinforcement. OMEGA™ II Fibersshould not be used as a means of reducing thickness ofconcretesectionsbeloworiginal design,nor to increase jointspacing past those dimensions suggested by PCA and ACIindustrystandardguidelineswithoutfirstconsultingourdesignengineeranddesignprogramforproperdosagerates.

STORAGE AND HANDLING

Storage Temperature: OMEGA™ II Fibers should be stored attemperatures below 140°F (60°C). Use caution when stacking toavoidunstableconditions.Storeinasprinkledwarehouse.PACKAGING OMEGA™IIFibersareavailable in50 lb. (22.7kg)boxesand2,400lbs. (1,089 kg) to a pallet. The boxes are palletized and stretch-wrappedtopreventdamagefromshippingandhandling.RELATED DOCUMENTS SafetyDataSheets:OMEGA™IIFiberADDITIONAL INFORMATION ForadditionalinformationonOMEGA™IIFibers,contactyourlocalsalesrepresentativeorCustomerServiceat(800)821-4391.DISCLAIMER OF WARRANTIES & LIMITATION OF LIABILITY SELLERANDMANUFACTURERDONOTMAKEANYWARRANTYWHATSOEVERREGARDINGTHIS

PRODUCT, EITHER EXPRESS OR IMPLIED, INCLUDING,WITHOUT LIMITATION, ANY IMPLIED

WARRANTYOFMERCHANTABILITY,FITNESSFORAPARTICULARPURPOSE,CONDITION,DESIGN

OR QUALITY. BUYER’S EXCLUSIVE REMEDY AND THE SELLER’S AND THEMANUFACTURER’S

EXCLUSIVELIABILITYFORANYCLAIMS,LOSSES,DAMAGESORINJURIESRESULTINGFROMTHE

USEOF THIS PRODUCT, SHALL BE LIMITED TO THE REPLACEMENTOF THE PRODUCTWITH

RESPECT TO WHICH DAMAGES ARE CLAIMED. IN NO CASE SHALL THE SELLER OR THE

MANUFACTURERBELIABLEFORDIRECT,CONSEQUENTIAL,SPECIAL,INCIDENTAL,PUNITIVEOR

INDIRECT DAMAGES RESULTING FROM THE PURCHASE OR USE OF THIS PRODUCT. BUYER

ACCEPTSTHISPRODUCTSUBJECTTOTHEFOREGOINGDISCLAIMERANDPURCHASESANDUSES

THIS PRODUCT AT BUYER’S OWN RISK. NO EMPLOYEE OR AGENT OF SELLER OR THE

MANUFACTURERISAUTHORIZEDTOVARYTHETERMSOFTHISDISCLAIMERINANYMANNER.

©2016GLPTFOIIPS12/05