STEED CREEK CLUBHOUSE - Pavilion Construction · 3/1/2012 · CONT Continuous DBA Deformed Bar...
Transcript of STEED CREEK CLUBHOUSE - Pavilion Construction · 3/1/2012 · CONT Continuous DBA Deformed Bar...
STEED CREEK CLUBHOUSE
DRAWING INDEX
STRUCTURAL ABBREVIATIONS:@ At& And' Feet" Inch# Number, Pound(E) Existing(N) New
AB Anchor BoltACI American Concrete InstituteADD Addendum, AdditionALT AlternateAPPROX ApproximateARCH Architect, ArchitecturalASTM American Society for Testing and MaterialsAVG AverageAWS American Welding Society
BEV BevelBLDG BuildingBLKG BlockingBM BeamBOT BottomBP Base PlateBRDG Bridge, BridgingBRG BearingBRK Brick
CJ Control JointCL CenterlineCLG CeilingCLR Clear
CMU Concrete Masonry UnitCOL ColumnCONC ConcreteCONN ConnectionCONT Continuous
DBA Deformed Bar AnchorDBL DoubleDET DetailDF Doug Fir (Douglas-Fir)DIAG DiagonalDIA DiameterDIM DimensionDL Dead LoadDWG DrawingDWGS DrawingsDWL Dowel
EA EachENG EngineerENGR EngineerEQ EqualEQUIP EquipmentEOR Engineer of RecordEW Each WayEXT Exterior
F TO F Face to FaceFAB FabricateFT Foot, FeetFTG Footing
GA GaugeGALV GalvanizedGC General ContractorGEN GeneralGL Glulam (Glue Laminated Beam)GR GradeGRND GroundGYP GypsumGYP BD Gypsum Board
HAS Headed Anchor StudHDD Headed StudsHDR HeaderHEX HexagonalHK Hook, HooksHORIZ HorizontalHSS Hollow Structural ShapeHVAC Heating, Ventilating, Air ConditioningHT Height
IBC International Building CodeIN InchINFO InformationINSP InspectINSUL InsulationINT Interior, Internal, intersection
JST Joist
K Kilopound (1000 pounds)KIP Kilopound (1000 pounds)
L Angle, Left, Length, LongLAM Laminate, LaminatedLAT LateralLB Pound (weight)LLH Long Leg HorizontalLLV Long Leg VerticalLL Live LoadLNTL LintelLONG LongitudinalLSL Laminated Strand LumberLT WT LightweightLVL Laminated Veneer Lumber
MAX MaximumMB Machine BoltMECH MechanicalMEZZ MezzanineMFD Manufactured, Metal Floor DeckMFG ManufacturingMFR Manufacture, ManufacturerMIN MinimumMISC MiscellaneousMTL Material, Metal
N NorthNO NumberNOM NominalNS Nelson StudNTS Not To Scale
OC On CenterOPNG Opening
OPP OppositeOWSJ Open Web Steel Joist
PAF Powder Actuated FastenersPCF Pounds per Cubic FootPERF Perforate, PerformancePERIM PerimeterPERP PerpendicularPL PlatePLF Pounds per Lineal FootPLWD PlywoodPREFAB PrefabricatedPSF Pounds per Square FootPSI Pounds per Square InchPSL Parallel Strand LumberPT Post-Tensioned, Preservative-Treated
QTY Quantity
REF Refer, ReferenceREINF Reinforcement, ReinforceREQ'D RequiredREV Revision
SCHED ScheduleSE Structural EngineerSECT SectionSF Square FootSL Snow LoadSIM SimilarSOG Slab on GradeSPEC Specification, Specifications
STD StandardSTIFF StiffenerSTL SteelSTRUCT Structural
T&B Top and BottomT&G Tongue & GrooveTAN TangentTHK Thick, ThicknessTOB Top of BeamTOF Top of FootingTOJ Top of JoistTOL Top of Lintel, LandingTOP Top of PierTOS Top of Slab, Top of SteelTOW Top of WallTOL ToleranceTRANS TransverseTYP Typical
UNO Unless Noted Otherwise
VERT Vertical
W/ WithW/O WithoutWD WoodWF Wide Flange (structural steel)WT WeightWWF Welded Wire FabricWF Wide Flange (structural steel)
SHEETNUMBER SHEET TITLE
TYPICAL SYMBOLS:NOTE: SOME SYMBOLS SHOWN MAY NOT BE IN USE
1
A
LETTER
REFERENCE GRID LINES
NORTH ARROW
N
KEY NOTE TAG
1
NUMBER
BUILDING SECTION
1S0.00
SHEET NUMBER
SECTION NUMBER
1S0.00
ELEVATION REFERENCEPARTIAL SECTION
SHEET NUMBER
SECTION NUMBER
1S0.00
1S0.00
SHEET NUMBER
ELEVATION NUMBER
DETAIL REFERENCE BUBBLE
DETAIL REFERENCE
1S0.00
SHEET NUMBER
DETAIL NUMBER
DETAIL BUBBLE
SHEET NUMBER
DETAIL NUMBER
1S0.00
NUMBER
WASHINGTON CO, OREGON
S1.00 STRUCTURAL COVER SHEET
S1.10 GENERAL STRUCTURAL NOTES
S2.10 CLUB HOUSE FOUNDATION PLAN
S2.50 CLUB HOUSE ROOF FRAMING PLAN
S4.10 FOUNDATION DETAILS
S4.11 FOUNDATION DETAILS
S5.10 FRAMING DETAILS
S5.11 FRAMING DETAILS
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s100
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:16
amXr
efs:
11-
t226
xtb
TB0
9055
0-24
x36
froe
lich-
logo
P:\2
011j
obs\
11-T
226
(Ste
ed C
reek
- C
lubh
ouse
)\Stru
ctur
al\C
urre
nt\1
1-t2
26s1
00.d
wg
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:16
am
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s100
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:16
am
STRUCTURALCOVER SHEET
General Structural NotesPROJECT DESCRIPTION:
NEW 1-STORY COMMUNITY CLUB HOUSE BUILDING.GANG NAILED WOOD ROOF TRUSSES.WOOD STRUCTURAL SHEATHED WOOD STUD WALL FRAMING.CONCRETE SLAB ON GRADE FIRST FLOOR.CONVENTIONAL FOUNDATION (CONCRETE SPREAD FOOTINGS, CONTINUOUS FOOTING W/ STEMWALLS)
DESIGN CODE:1. INTERNATIONAL BUILDING CODE, 2009 EDITION.2. STATE OF OREGON 2010 STRUCTURAL SPECIALTY CODE (OSSC) AMENDMENTS.3. ALL REFERENCE TO OTHER CODES AND STANDARDS (ACI, ASTM, ETC.) SHALL BE FOR THE
EDITIONS NOTED IN CHAPTER 35 OF THE IBC AND OSSC
OCCUPANCY CATEGORY (PER IBC TABLE 1604.5 II& ASCE 7 TABLE 1-1)
GROUND SNOW LOAD (Pg) 10 PSFFLAT-ROOF SNOW LOAD (Pf) 25 PSFSNOW EXPOSURE FACTOR (Ce) 1.0SNOW LOAD IMPORTANCE FACTOR (Is) 1.0THERMAL FACTOR (Ct) 1.0
BASIC WIND SPEED, 3 SEC GUST 95 MPHWIND EXPOSURE BWIND IMPORTANCE FACTOR (lw) 1.0
SEISMIC IMPORTANCE FACTOR (le) 1.0SITE CLASS DMAPPED SPECTRAL RESPONSE (Ss) 0.968MAPPED SPECTRAL RESPONSE (Sl) 0.353SPECTRAL RESPONSE COEFF. (Sds) 0.718SPECTRAL RESPONSE COEFF. (Sdl) 0.399SEISMIC DESIGN CATEGORY DBASIC SEISMIC FORCE RESISTING SYSTEM LIGHT FRAME WALLS WITH SHEAR PANELSRESPONSE MODIFICATION FACTOR (R) 6.5SEISMIC RESPONSE COEFFICIENT (Cs) 0.11DESIGN BASE SHEAR 6.1 KIPSANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE
ALLOWABLE SOIL BEARING PRESSURE 1500 PSF PER GEOTECHNICAL REPORTBY: GEO PACIFIC ENGINEERING, INC.DATED: MARCH 21, 2011PROJECT NO: 11-2249
DESIGN CRITERIA:
GENERAL:1. UNLESS OTHERWISE NOTED, ALL MATERIAL AND DESIGN SPECIFICATIONS CITED HEREIN SHALL
CONFORM TO THE MOST RECENTLY ADOPTED SPECIFICATION OF CODE.2. THESE STRUCTURAL NOTES ARE A SUPPLEMENT TO THE PROJECT SPECIFICATIONS. ANY
DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS, THESE NOTES, AND ANY SITECONDITIONS SHALL BE REPORTED IN A TIMELY MANNER TO THE ARCHITECT / ENGINEER OFRECORD WHO SHALL CORRECT ANY DISCREPANCY IN WRITING. ANY WORK DONE BY THECONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'SRISK.
3. THE CONTRACTOR SHALL VERIFY AND COORDINATE THE DIMENSIONS AMONG DRAWINGS PRIORTO PROCEEDING WITH ANY WORK OR FABRICATION.
4. THE STRUCTURAL DRAWINGS REPRESENT THE COMPLETED STRUCTURE AND ARE NOT INTENDEDTO INDICATE THE MEANS AND METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLEFOR ALL DEMOLITION AND CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCING, ANDSAFETY REQUIRED FOR THIS PROJECT.
5. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF ALL ERECTIONBRACING, FORM WORK, AND TEMPORARY SHORING REQUIRED FOR THIS PROJECT.
6. SEE SUBMITTAL KEY FOR REQUIRED SHOP DRAWING SUBMITTALS. UNLESS STATED OTHERWISEIN THE PROJECT SPECIFICATIONS, PROVIDE A MINIMUM OF TWO SETS OF SUBMITTALS FORAPPROVAL OR CORRECTIONS.
7. ALL FEATURES OF CONSTRUCTION NOT FULLY SHOWN SHALL BE OF THE SAME TYPE ANDCHARACTER AS SHOWN FOR SIMILAR CONDITIONS SUBJECT TO REVIEW BY THE ARCHITECT ANDSTRUCTURAL ENGINEER OF RECORD.
8. ALL PRODUCTS AND MATERIALS USED BY THE CONTRACTOR SHALL BE APPLIED, PLACED,ERECTED OR INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
9. THESE DOCUMENTS CONTAIN NOTES THAT MAY APPLY GENERALLY TO ALL STRUCTURALELEMENTS, SPECIFICALLY TO ONE SHEET, OR SPECIFICALLY TO ONE OR MORE STRUCTURALELEMENTS. THE NOTES ARE NOT MERE GUIDELINES, THEY ARE PART AND PARCEL OF OURDESIGN. ANY WORK THAT IS PERFORMED THAT IS NOT IN COMPLIANCE WITH THE NOTES IS NOT INCOMPLIANCE WITH THE DESIGN AND IS SUBJECT TO REJECTION. ANY ALTERATION, MODIFICATION,DELETION, OR ADDITION TO THE NOTES BY WRITING, ACT OR FAILURE TO ACT, SHALL BE CARRIEDOUT ONLY WITH THE PRIOR EXPRESS WRITTEN CONSENT AND APPROVAL OF FROELICHCONSULTING ENGINEERS.
1. A QUALIFIED SPECIAL INSPECTOR IS TO BE CONTRACTED BY THE OWNER PER IBC CHAPTER 17REQUIREMENTS, AND ALL LOCAL ORDINANCES.
2. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE ALL INSPECTIONS WITH THEDESIGNATED SPECIAL INSPECTOR IN A TIMELY MANNER PRIOR TO ALL WORK REQUIRING SPECIALINSPECTION.
3. ALL SPECIAL INSPECTORS SHALL BE CERTIFIED TO PERFORM THE NECESSARY INSPECTIONS ONTHE MATERIALS AND OPERATIONS INDICATED PER IBC, ACI, AWS OR OTHER APPROVEDGOVERNING INSTITUTION STANDARDS.
SPECIAL INSPECTIONS:
Post-Installed Anchors
Required Special Inspections:
Verification andInspection
INSTALLATION INHARDENED
CONCRETE ANDCOMPLETED
MASONRY
Continuous Periodic
Frequency ofInspection
IBC CodeReference
Code or StandardReference
1703.4.2,1704.15.3
INSPECTION
REMARKS
SPECIAL INSPECTIONS APPLY TOANCHOR PRODUCT NAME, TYPE,
AND DIMENSIONS, HOLEDIMENSIONS, COMPLIANCE WITH
DRILL BIT REQUIREMENTS,CLEANLINESS OF THE HOLE ANDANCHOR, ADHESIVE EXPIRATION
DATE, ANCHOR/ADHESIVEINSTALLATION, ANCHOR
EMBEDMENT, AND TIGHTENINGTORQUE.
ICCEVALUATION
REPORTX -
DEFERRED SUBMITTALS:1. PURSUANT TO THE IBC, SUBMITTAL DOCUMENTS FOR DEFERRED ITEMS SHALL BE PROVIDED TO THE
ARCHITECT AND/OR THE STRUCTURAL ENGINEER OF RECORD FOR REVIEW.
ITEM ARCHITECT OFRECORD
STRUCTURALENGINEER OF
RECORD
BUILDINGOFFICIAL
1. PRE-ENGINEERED ROOF TRUSSES X X X--------------------------------------------------------------------------------------------------------------------------------------------------------
1. FOUNDATION SIZES ARE BASED UPON A MAXIMUM TOTAL LOAD BEARING SOIL PRESSURE = 1500PSF FOR BEARING ON NATIVE SOILS/COMPACTED FILL.
2. FOOTING SHALL BE FOUNDED ON FIRM, UNDISTURBED SOIL OR ON APPROVED STRUCTURAL FILL.,AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER'S REPORT.
3. ALL FOOTINGS SHALL BE A MINIMUM OF 18" BELOW FINAL GRADES.4. ALL DISTURBED SOIL SHALL BE REMOVED BY HAND OPERATION FROM FOOTING EXCAVATIONS TO
NEAT LINES AND REPLACED WITH ENGINEERED FILL IF NECESSARY.5. THE CONTRACTOR SHALL REVIEW ALL GEOTECHNICAL ENGINEER RECOMMENDATIONS PRIOR TO
THE COMMENCEMENT OF ANY SITE WORK.6. BOTTOM OF FOOTINGS SHALL BE STEPPED FROM ELEVATION TO ELEVATION AT 2'-0" HORIZONTAL
TO 1'-0" VERTICAL STEPS OR SHALL BE SLOPED NOT TO EXCEED 1 VERTICAL TO 4 HORIZONTALWHEN APPROVED BY THE ENGINEER.
7. PLACEMENT OF ALL FILL SHALL BE OBSERVED AND TESTED FOR RELATIVE COMPACTION BY AQUALIFIED TECHNICIAN UNDER THE GUIDANCE OF THE GEOTECHNICAL ENGINEER. MINIMUMTESTING FREQUENCY SHALL BE ESTABLISHED BY THE GEOTECHNICAL ENGINEER.
8. THE CONTRACTOR SHALL NOTIFY THE GEOTECHNICAL ENGINEER PRIOR TO COMMENCEMENT OFFILLING OPERATIONS
9. ALL GENERAL EXCAVATIONS AND FOOTINGS SHALL BE INSPECTED AND APPROVED PRIOR TO THEPLACEMENT OF ANY SOIL BACKFILL AND/OR CONCRETE.
10. ALL FILL, BACKFILL AND COMPACTION ACTIVITIES, PARTICULARLY DURING WET WEATHERCONDITIONS, SHALL FOLLOW RECOMMENDATIONS OF GEOTECHNICAL ENGINEER.
FOUNDATIONS:
CONCRETE (CAST IN PLACE):1. ALL CONCRETE SHALL BE NORMAL WEIGHT AND SHALL HAVE THE FOLLOWING PROPERTIES:
NOTE: STRUCTURAL CALCULATIONS ARE BASED UPON 2500 PSI CONCRETE STRENGTH. PER IBCSEC. 1704.4, EXCEPTION 2.3, SPECIAL INSPECTION NOT REQUIRED.NOTE: COLUMNS THAT ARE AN INTEGRAL PART OF A WALL MUST HAVE CONCRETE STRENGTH ASREQUIRED FOR COLUMNS.
2. CONCRETE, FORMS, MIXING, PLACING AND CURING SHALL CONFORM TO ACI MANUAL OFCONCRETE PRACTICE, LATEST EDITION, AND SPECIFICATIONS.
3. CONCRETE SHALL BE PLACED IN ONE CONTINUOUS OPERATION.
3000 PSI 0.50FOOTINGS
DESCRIPTION 28-DAYSTRENGTH
WATER/CEMENTRATIO OTHER
0.50
0.43
3000 PSI
4000 PSI
STEMWALLS
ENTRAINED AIR
INTERIOR SLAB-ON-GRADE
512% +/- 1.5%
512% +/- 1.5%
NA
REINFORCING STEEL:1. ALL REINFORCING BARS SHALL CONFORM TO ASTM A-615 OF THE FOLLOWING GRADES: ASTM A615
GRADE 60 FOR ALL REINFORCEMENT ASTM A615 GRADE 40 FOR BEAM STIRRUPS, COLUMN TIES ANDAS NOTED.
2. REINFORCEMENT SHALL BE SECURED IN FORMS WITH SUITABLE TIES AND ANCHORAGE TOPREVENT DISPLACEMENT. BARS ADJACENT TO EARTH SHALL BE SUPPORTED BY CEMENT MORTARCUBES.
3. REINFORCEMENT STEEL SHALL NOT BE DISPLACED FOR THE CONVENIENCE OF OTHER TRADESUNLESS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
4. 'WET SETTING' OF REINFORCEMENT, ANCHOR BOLTS, AND INSERTS IS NOT PERMITTED5. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR CAST-IN-PLACE
REINFORCEMENT:A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED EARTH 3"B. CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 THROUGH #18 BARS 2"#5 BAR AND SMALLER 11
2"6. PLACE 2'-0" x 2'-0" BARS AT CORNERS AND INTERSECTIONS FOR WALLS AND FOUNDATIONS EQUAL
IN SIZE, NUMBER AND SPACING TO HORIZONTAL REINFORCING.7. REINFORCEMENT SPLICES, SHALL BE 48 BAR DIA. (24" MIN.), UNLESS NOTED OTHERWISE.8. UNLESS OTHERWISE NOTED, DOWEL CONCRETE WALLS TO FOOTING WITH BARS OF SAME SIZE &
SPACING AS WALL REINFORCEMENT.
MASONRY/STONE VENEER:1. VENEER SHALL NOT EXCEED 5" IN THICKNESS.2. PROVIDE 1" MIN (41
2" MAX) AIR SPACE BETWEEN VENEER AND STUD WALL SHEATHING. WALLSHEATHING TO BE COVERED WITH APPROVED WEATHER RESISTANT BARRIER.
3. VENEER ANCHORS ARE TO MEET THE REQUIREMENTS OF ACI 530-08.6.2.4. VENEER TO BE ANCHORED DIRECTLY TO WALL STUDS, COLUMNS, CONCRETE WALLS, CMU
WALLS, OR STRUCTURAL ELEMENTS. ANCHORS TO BE SPACED AT 16" O.C. HORIZONTALLY AND18" O.C. VERTICALLY, MAXIMUM. IN NO CASE IS THE AREA OF VENEER SUPPORTED BY EACHANCHOR TO EXCEED 2.0 SQ. FT.
5. USE 3/4" x 22 GAGE GALVANIZED METAL ADJUSTABLE ANCHORS OR # 9 GAGE GALVANIZED WIREANCHORS.
6. USE #9 GAGE GALVANIZED WIRE JOINT REINFORCEMENT HORIZONTALLY AT MAXIMUM OF 18" O.C.JOINT REINFORCEMENT TO BE SECURED TO SEISMIC ANCHORS.
7. ANCHORS TO MEET THE REQUIREMENTS OF SEISMIC DESIGN CATEGORY D.8. ISOLATE THE SIDES AND TOP OF ANCHORED VENEER FROM THE STRUCTURE SO THAT VERTICAL
AND LATERAL SEISMIC FORCES RESISTED BY THE STRUCTURE ARE NOT IMPARTED TO THEVENEER.
9. PROVIDE ADDITIONAL ANCHORS AROUND OPENINGS LARGER THAN 16" IN EITHER DIMENSION.SPACE ANCHORS AROUND PERIMETER OF OPENINGS AT A MAXIMUM OF 3'-0" O.C. PLACEANCHORS WITHIN 12" OF OPENINGS.
10. EMBED ANCHORS INTO THE MORTAR JOINT A MINIMUM DISTANCE OF 1 12" WITH AT LEAST 5
8"MORTAR COVER TO THE OUTSIDE FACE.
METAL PLATE CONNECTED TRUSSES:1. METAL PLATE CONNECTED TRUSSES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE
WITH "DESIGN SPECIFICATIONS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES", TPI-24 ASPUBLISHED BY THE TRUSS PLATE INSTITUTE AND SHALL BE DESIGNED FOR THE FOLLOWINGMINIMUM LOADS AND ANY SNOW DRIFTING/SLIDING SNOW INDICATED ON DRAWINGS:
TOP CHORD 25 PSF SNOW LOAD13 PSF DEAD LOAD
BOTTOM CHORD 7 PSFEAVES 2 x 25 PSF SNOW LOAD (ICE DAMS)TOTAL LOAD 43 PSF + SELF WEIGHTNET UPLIFT 10 PSF (0.6 D + W)
2. THE TRUSS MANUFACTURER SHALL SUBMIT DESIGNS, SHOP DRAWINGS AND CALCULATIONSBEARING THE STAMP OF A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE OFOREGON TO THE ARCHITECT FOR REVIEW.
3. DESIGN, SHOP DRAWINGS AND CALCULATIONS SHALL INCLUDE THE FOLLOWING INFORMATION:A. DEFLECTION DESIGN CRITERIAB. LIVE, SNOW, DEAD, WIND, SEISMIC AND MECHANICAL DESIGN LOADSC. ERECTION AND PLACEMENT CRITERIAD. DETAILS OF ALL BRIDGING, BRACING, STIFFENERS, BLOCKING AND CONNECTIONSE. LOCATION AND FRAMING FOR ALL EQUIPMENT LOADS OVER 500 LBSF. LOCATION AND FRAMING FOR ALL SUSPENDED WALLS AND EQUIPMENT
4. THE TRUSS MANUFACTURER SHALL SUPPLY ALL HARDWARE, ANCHORAGE, AND METAL SEATSREQUIRED, AND SHALL INDICATE BRACING AND OTHER ACCESSORIES, TO BE SUPPLIED BY THEGENERAL CONTRACTOR, NECESSARY FOR THE PROPER ERECTION & PERFORMANCE OF THEIRPRODUCT.
5. LOWER CHORDS SHALL BE CAMBERED TO PROVIDE FOR DEAD LOAD DEFLECTION AT GYPSUMBOARD CEILINGS.
6. CONTRACTOR TO VERIFY ALL WEIGHTS AND LOCATIONS OF CONCENTRATED LOADS DUE TO ROOFTOP MECHANICAL UNITS, MECHANICAL PIPING, ELECTRICAL UNITS, FOLDING PARTITIONS ANDOTHER CONCENTRATED LOADS PRIOR TO TRUSS FABRICATION.
7. DO NOT NOTCH OR DRILL TRUSS MEMBERS W/OUT APPROVAL OF THE TRUSS MANUFACTURERAND THEIR ENGINEER.
8. ALTERNATIVE PRODUCTS AND DESIGNS MUST BE APPROVED BY THE STRUCTURAL ENGINEER OFRECORD PRIOR TO BID.
GLUE LAMINATED MEMBERS:1. ALL GLUE LAMINATED TIMBER BEAMS SHALL BE DOUGLAS FIR 24F-V4 AT ALL SIMPLE BEAMS AND
GRADE 24F-V8 AT ALL CANTILEVER AND CONTINUOUS BEAMS, UNLESS OTHERWISE SPECIFIED ONTHE DRAWINGS.
2. ALL G.L. TIMBER SHALL BE FABRICATED IN ACCORDANCE WITH ANSI A190 MANUFACTURING, USINGD.F. LUMBER AND WATERPROOF ADHESIVE. EACH MEMBER SHALL BEAR AN AITC OR APAIDENTIFICATION MARK AND BE ACCOMPANIED BY AN AITC OR APA CERTIFICATE OFCONFORMANCE.
3. G.L. TIMBER BEAMS SHALL HAVE A 3500' RADIUS CAMBER, OR, AS INDICATED ON THE DRAWINGS.4. ALL G.L. MEMBERS SHALL BE NOTCHED, SHAPED AND FINISHED AS PER PLANS AND
SPECIFICATIONS.5. SEE SPECIFICATIONS FOR FINISH AND PROTECTION.6. ALL G.L. TIMBER COLUMNS SHALL BE COMBINATION 2.7. DO NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS ALLOWED PER CODE. ANY
PROPOSED NOTCHING OR DRILLING OF STRUCTURAL MEMBERS, BEYOND THE LIMITATIONS SETFORTH BY CODE, NEEDS TO HAVE PRIOR APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD.
SAWN FRAMING LUMBER:1. ALL SAWN LUMBER SHALL BE DOUGLAS FIR, S4S, GRADED IN ACCORDANCE WITH WCLIB RULE #16, OF THE
FOLLOWING GRADES:2x4 STUDS, 2x6 STUDS UP TO 10'-0": PARA. 121, NO. 22x6 STUDS OVER 10'-0", JOISTS, PLATES, 4x HEADERS, BLOCKING: PARA. 123, NO. 2BEAMS, 6x HEADERS: PARA. 130, NO. 1POSTS: PARA. 131, NO. 2 OR NO.1
(AS INDICATED ON PLANSAND DETAILS
2. ALL 2X LUMBER SHALL BE S-DRY, UNO.3. ALL PLATES AND LEDGERS IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESERVATIVE
TREATED PER AWPB SPECIFICATIONS. ALL PT LUMBER SHALL BEAR THE AWPB QUALITY MARK.4. ALL DIMENSIONAL LUMBER AND TIMBERS SHALL BE CERTIFIED IN WRITING BY THE SUPPLIER TO BE LESS
THAN 19% MOISTURE CONTENT.5. DO NOT NOT NOTCH OR DRILL STRUCTURAL MEMBERS, EXCEPT AS ALLOWED PER CODE. ANY PROPOSED
NOTCHING OR DRILLING OF STRUCTURAL MEMBERS, BEYOND THE LIMITATIONS SET FORTH BY CODE,NEEDS TO HAVE PRIOR APPROVAL BY THE ENGINEER OF RECORD.
SHEATHING:1. ALL SHEATHING SHALL BE EXPOSURE 1 CONFORMING TO DOC PS 1 OR PS 2 & SHALL HAVE AN APA
PANEL IDENTIFICATION INDEX STAMP UNLESS NOTED OTHERWISE ON DRAWINGS. PANELTHICKNESS & IDENTIFICATION INDEX SHALL BE AS FOLLOWS:
A. ROOF SHEATHING: 58"-INDEX 40/20
B. WALL SHEATHING: 716"-INDEX 32/16
2. SHEATHING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS AND ENDJOINTS SHALL BE STAGGERED.
3. PROVIDE 1 PLY CLIP PER SPAN @ UNSUPPORTED EDGE OF ROOF SHEATHING WHERE JOISTSPACING EXCEEDS 16" O.C. U.N.O. AS BLOCKED EDGES.
4. BLOCK ALL WALL SHEATHING AS REQUIRED PER SHEARWALL SCHEDULE.
NAILING AND FASTENERS:1. NAILING INDICATED ON PLANS AND DETAILS ARE "COMMON" NAILS. MINIMUM FRAMING NAILING SHALL
CONFORM TO IBC TABLE 2304.9.1. SEE DETAILS FOR ADDITIONAL TYPICAL NAILING REQUIREMENTS.SUBSTITUTION OF NAILS OTHER THAN "COMMON" IS NOT PERMITTED WITHOUT PRIOR APPROVAL.
2. POWER DRIVEN NAILS OTHER THAN "COMMON" NAILS MAY BE USED IF DATA IS SUBMITTED ANDAPPROVED PRIOR TO USE.
3. PLYWOOD NAILING SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE ON PLANS:A. ROOF SHEATHING 8d AT 6" O.C. AT ALL SUPPORTED PANEL EDGES
8d AT 12" O.C. ALONG INTERMEDIATE FRAMINGB. WALL SHEATHING 8d AT 6" O.C. AT ALL PANEL EDGES U.N.O. ON PLANS
8d AT 12" O.C. ALONG INTERMEDIATE STUDSBLOCK ALL EDGES WITH 2 x 4 FLATS
4. ALL BOLTED CONNECTIONS SHALL BE MADE WITH MACHINE BOLTS (M.B.) CONFORMING TO ASTM A307.ALL BOLTS AND LAGS SHALL BE INSTALLED WITH STANDARD WASHERS, UNLESS NOTED.
5. JOIST HANGERS, HOLD DOWNS, AND OTHER FRAMING ACCESSORIES ARE REFERRED TO ON PLANS BYPARTICULAR TYPE AS MANUFACTURED BY SIMPSON COMPANY - SAN LEANDRO, CA. ALL HARDWARE ISTO BE FASTENED PER MANUFACTURER'S SPECIFICATIONS, U.N.O.
6. SILLS AT WALLS SHALL BE BOLTED TO CONCRETE WITH 12" DIAMETER x 7" EMBED ANCHOR BOLTS AT
4'-O" O.C. MAXIMUM AND WITHIN 1'-O" OF SILL PLATE ENDS, CORNERS OR SPLICES, UNLESS DETAILEDOTHERWISE. AT SHEARWALLS, USE STEEL PLATE WASHERS AT ALL ANCHOR BOLTS. WASHERS TO BEMINIMUM 1/4"x3"x3" AS PER IBC 2305.3.11.
7. ALL PLATES AND LEDGERS SHALL BE ANCHORED WITH A MINIMUM OF THREE FASTENERS PER PIECE.8. EPOXY ANCHOR BOLTS AND ADHESIVE INDICATED ON DRAWINGS SHALL BE OF TYPE AS NOTED ON
DRAWINGS, OR APPROVED EQUAL. DEPTH OF EMBEDMENT SHALL BE AS PER MANUF. SPECIFICATIONS,UNLESS NOTED OTHERWISE. INSTALL ALL EPOXY FASTENERS IN STRICT ACCORDANCE WITH THEMANUFACTURER'S REQUIREMENT
9. ALL FASTENERS FOR PRESSURE TREATED WOOD SHALL BE CORROSION RESISTANT PER THEREQUIREMENTS OF IBC 2304.9.5.
a. HOT-DIPPED ZINC-COATED GALVANIZED STEELb. STAINLESS STEEL
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s110
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:16
am
GENERALSTRUCTURAL
NOTES
9" TYP
9"TYP
9"TYP
STD-
STD-
A1
A1
B1
STD1
STD1
B2
B2
B1
STD1
CENTER FOOTINGON WALL
CENTER FOOTINGON WALL
B1
SLOPE & DRAINSLAB PER ARCH
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
4" CONCRETE SLAB ONGRADE W/ #3 @ 18" OC EA
WAY OVER VAPORRETARDER & COMPACTEDSUBGRADE PER GEOTECH
4" CONCRETE SLAB ONGRADE W/ #3 @ 18" OC EA
WAY OVER VAPORRETARDER & COMPACTEDSUBGRADE PER GEOTECH
4" CONCRETE SLAB ONGRADE W/ #3 @ 18" OC EA
WAY OVER VAPORRETARDER & COMPACTEDSUBGRADE PER GEOTECH
7S4.10
8S4.10
7S4.10
8S4.10
TYP7
S4.108
S4.10TYP
9S4.10
6S4.10
TYP
11S4.10
TYP@ CJ
10S4.10
TYP
7S4.10
10S4.10
TYP
5S4.10
TYP
TYP
7S4.10
TYP
12S4.11
TYP (2)
7S4.10
7S4.10
TYP4S4.10
TYP
1S4.10
IF REQ'D
7S4.10
TYP
8S4.10
1 TYP
1 TYP
1 TYP1 TYP
1TYP
1TYP
1TYP 1 TYP
1 TYP
1 TYP
2 TYP
2TYP
33
13S4.10
22S5.11
1'-4"1'-4"
BALLOON FRAMECHIMNEY W/ 11
2"x512"
1.3E LSL STUDS
HTT5
HTT5
HTT5
HTT4
HTT4
HTT4
HTT4
HTT4
HTT4
HTT4HTT4HTT4HTT4
HTT4
HTT4
HTT4HTT4
HTT4
HTT4
HTT5
9" TYP
9" TYP
8S4.10
@ DOOR
@ DOOR
TYP
4
RAISEDCONCRETE CURB
@ DOOR
6x6 DF#1 6x6 DF#1
6x6 DF#16x6 DF#1
CJ
CJ
CJ
CJ
CJ
21S5.11
WINDOW FRAMING
SCALE:
1S2.101/4"=1'-0"
11-T226
Shear Wall ScheduleSheathing - Nailing Mud Sill Plate and Anchor Bolts (See note 6) Comments
-
7/16" APA RATED SHT'G (1) SIDE W/8d NAILS @ 6" OC EDGES & 12"OC FIELDSTD 2x SILL PL. W/ 1/2"Ø A.B. @ 42" OC (EMBED 7")
A 7/16" APA RATED SHT'G (1) SIDE W/8d NAILS @ 4" OC EDGES & 12"OC FIELD
2x SILL PL. W/ 1/2"Ø A.B. @ 32" OC (EMBED 7")
7/16" APA RATED SHT'G (1) SIDE W/8d NAILS @ 3" OC EDGES & 12"OC FIELD
2x SILL PL. W/ 1/2"Ø A.B. @ 18" OC (EMBED 7") SEE NOTE 8 BELOWB
-
-
SHEAR WALL GENERAL NOTES : (APPLY TO ALL SHEAR WALLS)1. IF A.B. SPACING IS GREATER THAN SHEAR WALL LENGTH INSTALL (1) A.B. WITHIN 12" OF EACH END AS PER OSSC SECTION 2308.6.2. SHEAR WALL FRAMING IS TO BE 16" OC UNLESS NOTED OR DETAILED OTHERWISE.3. SHEAR WALLS ARE TO BE BLOCKED AT ALL PANEL EDGES UNLESS NOTED OR DETAILED OTHERWISE.4. ALL NAILS STATED ARE COMMON NAILS UNLESS NOTED OTHERWISE. 8d GALVANIZED BOX NAILS SHALL BE SUBSTITUTED FOR THE 8d COMMON NAILS INTO
PT SILL PL.8d = 0.131x21
2"16d = 0.162 x 31
2"5. LTP4 PLATES SHALL BE INSTALLED W/(12) 8d COMMON NAILS.6. ANCHOR BOLTS SHALL BE GALVANIZED & SHALL HAVE A 1/4"x3"x3" GALVANIZED PL WASHER BETWEEN THE SILL PL & NUT. ANCHOR BOLTS SHALL BE
PLACED SO THAT THE EDGE OF THE PL WASHER IS 12" MAX FROM THE SHEATHED FACE OF THE WALL. WHERE SHEATHING IS APPLIED TO BOTH FACES,
ALTERNATE ANCHOR BOLTS - SEE DETAIL 3/S4.10 FOR ANCHOR BOLT PL WASHER REQUIREMENTS.7. PENETRATIONS GREATER THAN 4" WIDE x 4" TALL IN THE SHEATHING OF SHEAR WALLS SHALL NOT OCCUR UNLESS APPROVED BY ENGINEER.
PENETRATIONS SMALLER THAN 4" WIDE & 4" TALL SHALL BE BLOCKED ABOVE & BELOW (STUD-STUD) & EDGE NAILED.
SHEAR WALL SPECIFIC NOTES:8. FRAMING AT ADJOINING PANEL EDGES SHALL BE 3" NOMINAL OR GREATER & NAILS SHALL BE STAGGERED. (DBL. 2x ARE ACCEPTABLE W/16d @ 4" OC
STAGGERED).
5.
-
INDICATES SHEAR WALL. SEE SHEAR WALL LEGEND, SHEAR WALL SCHEDULE, & HOLDOWN SCHEDULE ONTHIS SHEET FOR MORE INFORMATION.
6. INDICATES LOAD BEARING WALL, FRAMING TO BE 2x DF#2 STUDS @ 16" OC UNO (SEE ARCH DRAWINGS FORWALL WIDTH)
4.
H.D.
X3.
7. INDICATES NON-LOAD BEARING PARTITION WALL BELOW, FRAMING TO BE 2x DF#2 STUDS @ 16" OC, UNO (SEEARCH DRAWINGS FOR WALL WIDTHS)
1. VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL DRAWINGS.
2. DETAILS ON THESE PLANS ARE INTENDED TO DEPICT THE GENERAL CONSTRUCTION METHODS FOR THIS STRUCTURE.CONNECTIONS, DETAILS AND CONDITIONS NOT SPECIFICALLY SHOWN THAT ARE SIMILAR TO THOSE THAT ARE SPECIFIED SHALLBE ASSUMED ONE AND THE SAME. IF QUESTIONS REGARDING THE APPLICATION OF DETAILS ARE ENCOUNTERED, NOTIFY THEARCHITECT / ENGINEER FOR CLARIFICATION IN A TIMELY MANNER PRIOR TO BID OPENING.
INDICATES FOOTING TYPE. SEE FOOTING SCHEDULE ON THIS SHEET FOR MORE INFORMATION.
INDICATES HOLDOWN. SEE HOLDOWN SCHEDULE ON THIS SHEET.
Foundation Plan Notes
Footing Schedule-
18" WIDE x 10" DEEP x CONT1LONG: (2) #4
TRANS: #4 @ 48" OC
16" WIDE x 10" DEEP x CONT2
3 3'-0" x 3'-0" x 12" DEEP (4) #4 EA WAY - EQ SPACEDAT BOTTOM
LONG: (2) #4TRANS: #4 @ 48" OC
Size Reinforcing Notes
4 10" DEEP x AS SHOWN #4 @ 12" OC EA. WAY ATBOTTOM
1. NAIL HOLDOWN MEMBERS W/ (2) ROWS OF 16d @ 6" OC STAGGERED FULL HEIGHT (TYP.)2. ALL HOLDOWNS AND ANCHORS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.3. NAILS ARE TO BE COMMON NAILS UNLESS NOTED OTHERWISE.4. SEE DETAILS 2/S4.10, 4/S4.10, 5/S4.10 FOR TYPICAL HOLDOWN INSTALLATION.5. HOLDOWNS OCCUR @ EACH END OF WALL.
-
1
2
NONE REQUIRED-
HOLDOWN GENERAL NOTES :
Holdown ScheduleHoldown Attachment to Framing Member Minimum Framing
Member SizeAttachment to Foundation ONU on
Plans or Details Comments
USE SIMP. SSTB24L INTO STEM WALL.USE 5 8" DIA ASTM A36 HEX HEAD A.B.
EMBED 6" INTO FTG. W/ 38"x11
2"x112" PL
WASHER BETWEEN DBL. NUT @ BOT.OF THREADED ROD WHEN NO STEM
WALL OCCURS.
PROVIDE #4 DOWEL W/STANDARD HOOK @ EACH
HOLDOWN LOCATION(2) 2x STUDS(18) 16dx21
2 NAILSSIMPSON HTT4
PROVIDE #4 DOWEL W/STANDARD HOOK @ EACH
HOLDOWN LOCATION
USE SIMP. SSTB24L INTO STEM WALL.USE 5 8" DIA ASTM A36 HEX HEAD A.B.
EMBED 6" INTO FTG. W/ 38"x11
2"x112" PL
WASHER BETWEEN DBL. NUT @ BOT.OF THREADED ROD WHEN NO STEM
WALL OCCURS.
(2) 2x STUDSSIMPSON HTT5 (26) 16dx212 NAILS
Holdown Embedment Detail
SSTBJAMBNUTTED
EMBE
DLE
NG
TH
3" MIN. CLR TO BOTTOM OFFOOTING -TYP
8" MIN. THREADEDPROJECTION -TYP
FOOTING
STEMWALL (ASOCCURS)
FOOTING
3x SILL PL PER SHEARWALL SCHEDULE
PL WASHER PERHOLDOWN SCHEDULE
1. ANCHOR RODS TO BE ASTM F1554 GRADE 36, A36 OR A307 ONU2. NUTS FOR ANCHOR RODS SHALL BE STANDARD HEX NUTS TYPE ASTM A563-A.3. WASHER FOR ANCHOR RODS SHALL BE ASTM F844. PROVIDE WASHER BETWEEN ALL NUTS AND BASE PL's.4. ANCHOR BOLTS SHALL NOT BE IN CONTACT W/ PRESSURE TREATED (PT) WOOD. PT WOOD PLATES SHALL HAVE OVERSIZED HOLES 1
4" MINIMUM & 38"
MAXIMUM LARGER THAN ROD SIZE. AS AN ALTERNATE, THE ANCHOR SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A653.
HOLDOWN SCHEDULE NOTES :
Shear Wall Legend
A
1
A
1
ONE HOLDOWN IS ALWAYS TO BE LOCATED AT EACH END OF EACH SHEAR WALL AS INDICATEDBELOW ("HD") UNLESS NOTED OTHERWISE. HOLDOWNS MAY OR MAY NOT BE INDICATED BY ADOT (AS SHOWN BELOW) ON THE PLANS.
SEE SCHEDULED INFORMATION FOR EACH APPLICABLE SYMBOL SHOWN.
UNLESS NOTED OTHERWISEON THE PLANS.
- INDICATES HOLDOWN TYPE
- INDICATES SHEAR WALL TYPEEXTENT OFSHEAR WALL
HDHD
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 1
1-t2
26xp
lan0
xPl
an x
Grid
11-
t226
xwal
ls 1
1-t2
26xs
hear
sche
d 1
1-t2
26xf
ndnp
lann
otes
11-
t226
xftg
11-
t226
xhol
d 1
1-t2
26xs
hear
legn
d fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s210
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:16
am
CLUB HOUSEFOUNDATION
PLAN
PRE-MFR ROOF
TRUSSES @ 24" O.C.
PRE-MFR ROOF
TRUSSES @ 24" O.C.
PRE-
MFR
RO
OF
TRUS
SES
@ 2
4" O
.C.
PRE-
MFR
SCI
SSO
R
TRUS
SES
@ 2
4" O
.C.
11S5.10
RIDGE RIDGE
RID
GE
RID
GE
4'-0
"
2x4 DF#2 ROOF
OUTLOOKERS @ 12" OC
4x10 DF#2 HDR- TYP UNO
PRE-MFR ROOFTRUSSES @24" OC
6x6 DF#1
6x6 DF#1 4x6
DF#
2PU
RLI
N
4x8
DF#
2PU
RLI
N
4x6
DF#
2PU
RLI
N
518 x 12 COMB 2 GL
BELOW
518x9 COMB 2 GL
6x8 DF#2 HDR 6x8 DF#2 HDR 6x8 DF#2 HDR
4x10
DF#
2 H
DR
- TYP
UN
O
PRE-MFR ROOFTRUSSES @24" OC
518 x 101
224F-V4 GL
6x10
DF#
2
58" APA RATED SHTH OVER 2x6
T&G SELECT DECKING INCONTROLLED RANDOM
PATTERN - TYP
30 PSF8'-0"
30 PSF8'-0"
3S5.10
1S5.10
4S5.10
1S5.10
7S5.10
3S5.10
11S5.10
1S5.10
1S5.10
7S5.10
TYP
TYP
TYP
TYP TYP BETWEENGRIDS B & C TYP
TYP
TYP
TYP
6S5.10
5S5.10
8S5.10
6S5.10
5
S5.10
6S5.10
5S5.10
8S5.10
6S5.10
TYP TYP
TYP @RIDGE
TYP
TYP @RIDGE
TYP @RIDGE
TYP
TYP
TYP
4x10 DF#2 HDR -TYP UNO
4x10 DF#2 HDR -TYP UNO
58" APA RATED
ROOF SHTH - TYP
58" APA RATED
ROOF SHTH - TYP
58"
APA
RAT
EDR
OO
F SH
TH -
TYP
3
1 2
3
12
GIRDER TRUSS
GIRDER TRUSS 4'-0
"
TYP
4423
S5.11
22S5.11
DR
AG T
RU
SS
10S5.10
@ BEAM
9S5.10
@ BEAM
10S5.10
@ BEAM
GIRDER TRUSS
(1) 2x6 CRIPPLE W/(2) 2x6 KINGS
(1) 2x6 CRIPPLE W/(2) 2x6 KINGS
DBL 2x6
DBL 2x6
(2) 2x6
(2) 2x6
(2) 2x6
LOUVER @ GABLEEND TRUSS - SEE
ARCH FOR LOCATION
LOUVER @ GABLEEND TRUSS - SEE
ARCH FOR LOCATION
51 8x12
GL
6x6 DF#1 (SEALEDPER ARCH)
4x6 W/ (2) 2x6KINGS
12S5.10
TYP (2)
16S5.11
TYP
518x9 COMB 2 GL
15S5.11
14S5.11
TYP (2)
21S5.11
WINDOW FRAMING
17S5.11
GL ROOF TRUSS
13S5.11 TYP
NOTE:SEE ARCH FOR SEALED FINISHREQUIREMENTS FOR PURLINS& GL ROOF TRUSS
51 8x12
GL
6x6 DF#1 (SEALEDPER ARCH)
4x6 W/ (2) 2x6KINGS
(1) 2x6 CRIPPLEW/ (2) 2x6 KINGS
(1) 2x6 CRIPPLEW/ (2) 2x6 KINGS
(2) 2x6
GIRDER TRUSS
TRUSSTRUSSD
RAG
TR
USS
6x10
DF#
2
SCALE:
1S2.501/4"=1'-0"
11-T226
3.
Roof Framing Plan Notes
-
4.
-
INDICATES SHEAR WALL BELOW. SEE SHEAR WALL LEGEND, SHEAR WALL SCHEDULE, & HOLDOWNSCHEDULE ON THIS SHEET FOR MORE INFORMATION.
5. INDICATES LOAD BEARING WALL BELOW, FRAMING TO BE 2x DF#2 STUDS @ 16" O.C. U.N.O. (SEE ARCH.DRAWINGS FOR WALL WIDTH)
6. INDICATES NON-LOAD BEARING PARTITION WALL BELOW, FRAMING TO BE 2x DF#2 STUDS @ 16" O.C.,U.N.O. (SEE ARCH. DRAWINGS FOR WALL WIDTHS)
7. INDICATES ROOF OVERFRAMING. SEE DETAIL 6/S5.10.
9.
10.
11.
12.
13.
8. INDICATES DRIFT LOAD & SLIDING SNOW LOADS. TRUSS MANUFACTURER SHALL ACCOUNT FORINDICATED LOADS IN DESIGN OF TRUSS.30 PSF
7'-6"
INDICATES KEYED NOTE, SEE ROOF FRAMING KEYED NOTES SCHEDULE ON THIS SHEET.
PROVIDE 4x10 DF#2 HEADER @ ALL WINDOW & DOOR OPENINGS W/ (1) CRIPPLE & (1) KING ON EACH END OF HEADER, TYP.U.N.O. SEE DETAIL 2/S5.10 FOR TYPICAL CONSTRUCTION.
SUPPORT ALL GIRDER TRUSSES W/ MIN OF (2) 2x6 STUDS @ EACH FLOOR TO FOUNDATION UNLESS NOTED OTHERWISE (TYP)
FOR TYPICAL DOUBLE TOP PL SPLICE, SEE DETAIL 7/S5.10 UNLESS NOTED OTHERWISE.
PROVIDE SIMPSON LSTA36 STRAP CENTERED @ ALL DOUBLE TOP PL BREAKS W/ (13) 16d SINKERS TO EACH SIDE OFDOUBLE TOP PL BREAK (26) TOTAL NAILS. TYPICAL UNLESS NOTED OTHERWISE.
TRUSS MANUFACTURER TO REVIEW ALL DETAILS & PLANS TO ACCOUNT FOR SPECIFIC CONDITIONS.
1. VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL DRAWINGS.
2. DETAILS ON THESE PLANS ARE INTENDED TO DEPICT THE GENERAL CONSTRUCTION METHODS FOR THIS STRUCTURE.CONNECTIONS, DETAILS AND CONDITIONS NOT SPECIFICALLY SHOWN THAT ARE SIMILAR TO THOSE THAT ARE SPECIFIEDSHALL BE ASSUMED ONE AND THE SAME. IF QUESTIONS REGARDING THE APPLICATION OF DETAILS ARE ENCOUNTERED,NOTIFY THE ARCHITECT / ENGINEER FOR CLARIFICATION IN A TIMELY MANNER PRIOR TO BID OPENING.
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 1
1-t2
26xp
lan1
xPl
an x
Grid
11-
t226
xwal
ls x
Roo
f 11
-t226
xroo
fpla
nnot
es f
roel
ich-
logo
11-
t226
xroo
ffram
ingK
eyN
otes
P:\2
011j
obs\
11-T
226
(Ste
ed C
reek
- C
lubh
ouse
)\Stru
ctur
al\C
urre
nt\1
1-t2
26s2
50.d
wg
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:17
am
CLUB HOUSEROOF FRAMING
PLAN
1. NAIL ROOF SHEATHING TO DRAG TRUSS BELOW W/ MIN OF 8d NAILS @ 6" O.C. UNO ON PLAN.
2. ALIGN DRAG TRUSS W/ WALL BELOW. DESIGN TRUSS FOR AXIAL LOAD OF 1.0W = 3000 LBS TENSION OR COMPRESSION. SEEDETAIL 8/S5.10 FOR ALIGNMENT AND CONNECTION TO WALL BELOW.
3. ATTACH DRAG TRUSS TO SHEAR WALL WITH (5) SIMPSON LTP4 CLIPS, EQUALLY SPACED.
4. SIMPSON CS18 x AS SHOWN W/ (2) ROWS OF 8d NAILS @ 4" O.C. TO 2x CONT. BLKG BETWEEN TRUSSES & GIRDER TRUSS.
5. BALLOON FRAME STUDS CHIMNEY W/ 112"x51
2" 1.3E LSL.
Roof Framing Keyed Notes=
SCALE:
1S4.101"=1'-0"
11-T226SCALE:
2S4.101"=1'-0"
11-T226
SCALE:
4S4.101"=1'-0"
11-T226SCALE:
5BS4.101"=1'-0"
11-T226SCALE:
6S4.101"=1'-0"
11-T226SCALE:
7S4.101"=1'-0"
11-T226
SCALE:
8S4.101"=1'-0"
11-T226SCALE:
9S4.101"=1'-0"
11-T226SCALE:
10S4.101"=1'-0"
11-T226SCALE:
11S4.101"=1'-0"
11-T226
HH
MINIMUM
HF
HH
2x "H"
2x "H"1'-6"
LONG BARS TO MATCHLONG FOOTING BARS
TYP WALL FTG
TYP WALL FTG
LONG BARSPER PLAN
NOTE:DO NOT SLOPE FOOTINGSUNDER ANY CONDITIONS.
REINF LAP
PER PLAN
REINF LAP
PER PLAN
SHEARWALL SHEATHING& NAILING PERSHEARWALL SCHEDULE
HOLDOWN POST PERHOLDOWN SCHEDULE
EDGE OF ROUGH OPENINGOR CORNER OF BUILDING
HOLDOWN &HOLDOWN ANCHOR
PER HOLDOWNSCHEDULE
SILL PL AND SILLANCHORS PER
SHEAR WALLSCHEDULE
PROVIDE AN ADDITIONALFOUNDATION WALL DOWELADJACENT TO HOLDOWN PERHOLDOWN SCHEDULE
EXTE
NT
OF
SHEA
R W
ALL
STEMWALL &FOOTING PER PLAN
5" MIN
CL
SHEAR WALLPER PLANS
BLK'G FOR GYPBOARD NOTSHOWN
ADDITIONAL STUD ASREQ'D - SEE NOTE
SHEAR WALLPER PLANS
HOLDOWN PER PLAN &SCHED (USE GREATER OF
THE (2) HOLDOWNS)
EDGE OF CONC
EDGE NAILING PERSHEAR WALL SCHED
16d NAILS @ 4" OC
POST PER HOLDOWNSCHEDULE
NOTE:HOLDOWN BOLT TO BE PLACED 5" MINFROM EDGE OF CONCRETE. ADDADDITIONAL 2x STUD AS REQUIRED &FASTEN TO DBL 2x HOLDOWN POST W/16d @ 4" OC STAGGERED
CRIPPLE STUD(S) PER PLAN& BEAM SCHEDULE
OPENING PER PLAN
STAGGER SHEARWALL EDGE NAILINGTO HOLDOWN POSTUSE THE GREATER OF THE
KING POST OR THEHOLDOWN POST
2x STUD WALL PER PLAN
HOLDOWN PER PLAN& HOLDOWN SCHED
SHEAR WALL SHEATHING PER PLAN& SHEAR WALL SCHED (MAY REQ'D
ON BOTH SIDES OF WALL)
CRIPPLE STUD(S)PER PLAN
STAGGER SHEAR WALLEDGE NAILING BETWEENDBL STUDSUSE THE GREATER OF THE
KING STUDS OR THEHOLDOWN POST
2x STUD WALL PER PLAN
HOLDOWN PER PLAN& HOLDOWN SCHED
OPENING PER PLAN
SCALE:
5AS4.101"=1'-0"
11-T226
1'-0"
1'-6
" MIN
SEE PLAN FOR
SIZE & REINF
3" CLR
8"
PL WASHER PER SHEAR WALL SCHED& DETAIL 3/S4.10
IF STEM WALL HEIGHT ISGREATER THAN 2'-6" ADD
ADDITIONAL #4 HORIZ @ 12"OC
2" CLR
1'-0
" MIN
- TYP
(1) #4 CONT @ TOP
SHEAR WALL -SEE SHEARWALL SCHEDULE FOR MORE
INFO
PT SILL PL, ANCHOR BOLT SIZE & SPACINGPER PLAN & SHEAR WALL SCHEDULE (SILL
PL IN CONTACT W/ CONCRETE TO BE PT)
EDGE NAILING -SEE SHEARWALL SCHEDULE STAGGER
NAILING
CONC SLAB-ON-GRADE -SEEPLANS FOR ADDITIONALINFORMATION
4"
6"
REINF PER PLAN
11 2" C
LR
DOWELS @ 24" OC(ALT HOOKS)
11
AIR GAP & VENEER PERARCH
#4x
3" C
LR
SEE PLAN FOR SIZE
& REINF
CONC SLAB ON GRADE, (SEEPLAN FOR SIZE & REINF )
(1)-#4 CONT
WALL BEYOND
DOWEL SLAB REINFAS SHOWN
1'-6
"
MIN
21 #4 DOWELS @ 48" OC (ALT HOOKS)
EXTERIOR SLAB PERARCH & CIVIL
FTG
. DEP
TH
PER
PLA
N
3" C
LR3" CLR
SEE PLAN FORFOOTING SIZE & REINF
21
2x STUD WALL PER PLAN
SHEAR WALL - SEE SHEAR WALLSCHEDULE FOR MORE INFO
PL WASHER PER SHEAR WALLSCHEDULE & DETAIL 3/S4.10
EDGE NAILING - SEE SHEARWALL SCHEDULE
SLAB ON GRADE SEEPLAN
REINF PER PLAN
PT SILL PL, ANCHOR BOLT SIZE & SPACINGPER PLAN & SHEAR WALL SCHEDULE (SILL
PL IN CONTACT W/ CONCRETE TO BE PT)
CL
OF
STEM
WAL
L&
FTG
FTG
. DEP
TH
PER
PLA
N
3" C
LR3" CLR
SEE PLAN FORFOOTING SIZE & REINF
21
2x PT SILL PL W/ 12"∅ AB (7" EMBED) @ 48"
OC (SILL PL IN CONTACT W/ CONCRETE TOBE PT)
2x STUD WALL PER PLAN
SLAB ON GRADE SEEPLAN
REINF PER PLAN
REINF PER PLAN
CL
OF
STEM
WAL
L &
FTG
6"
CONSTRUCTION JOINT
CONTROL JOINT
6"
11
4"
SEE PLAN FOR REINFINFORMATION
CONCRETE SLAB ON GRADE SEEPLANS FOR ADDITIONAL INFORMATION1
8" x 112" SAW JOINT. SAW AS SOON AS CONC WILL
SUPPORT WEIGHT OF MACHINE WITHOUT MARRINGTHE SURFACE. FILL JOINT WITH JOINT FILLER.
APPLY ACCORDING TO MANUFACTURER'SRECOMMENDATIONS.
ROCK PER GEOTECHRECOMMENDATION
12" DIA x 36" SMOOTH DOWEL @ 24" OC
GREASE OR WRAP ONE END OF EACHDOWEL
CONCRETE SLAB ON GRADE- SEEPLANS CONCRETE SLAB ON FOR
ADDITIONAL INFO
SEE SLAB FOR REINF INFO
NOTES:CONTRACTOR MAY USE EITHER CONTROLJOINTS OR CONSTRUCTION JOINTS ATLOCATIONS INDICATED ON PLANS.
CL CONTROLJOINT
CL CONTROLJOINT
112" CLR
112" CLR
CUT EVERY OTHER BARPERPENDICULAR TO JOINT
FOUNDATION DRAIN PERGEOTECH
FOUNDATION DRAINPER GEOTECH
SHEAR WALL SHEATHING PER PLAN& SHEAR WALL SCHED (MAY REQ'D
ON BOTH SIDES OF WALL)
RIGID INSULATIONPER ARCH
FTG
. DEP
TH
PER
PLA
N
3" C
LR3" CLR
SEE PLAN FORFOOTING SIZE & REINF
21
2x STUD WALL PER PLAN
SHEAR WALL - SEE SHEAR WALLSCHEDULE FOR MORE INFO
PL WASHER PER SHEAR WALLSCHEDULE & DETAIL 3/S4.10
EDGE NAILING - SEE SHEARWALL SCHEDULE
SLAB ON GRADE SEEPLAN
REINF PER PLAN
PT SILL PL, ANCHOR BOLT SIZE & SPACINGPER PLAN & SHEAR WALL SCHEDULE (SILL
PL IN CONTACT W/ CONCRETE TO BE PT)
CL
OF
STEM
WAL
L&
FTG
#4 DOWEL @ 24" OC (ALTHOOKS)
#4 CONTCONCRETE CURB PER ARCH
CONTRACTOR OPTION:REPLACE CAST-IN A.B. W/ EITHER:1
2" DIA. A307 THREADED ROD EPOXY EMBED 6" MIN W/SIMPSON SET-XP EPOXY.
12" DIA. SIMPSON STRONG-BOLT 2 WEDGE ANCHOR.
CONTRACTOR OPTION:REPLACE CAST-IN A.B. W/ EITHER:1
2" DIA. A307 THREADED ROD EPOXY EMBED 6" MIN W/SIMPSON SET-XP EPOXY.
12" DIA. SIMPSON STRONG-BOLT 2 WEDGE ANCHOR.
SCALE:
3BS4.103"=1'-0"
11-T226SCALE:
4S4.101"=1'-0"
11-T226
SCALE:
3AS4.103"=1'-0"
11-T226
13 4"
MAX
3"
3"
BOLT DIAMETER + 116" DIA
HOLE CENTERED IN PL
14" GALVANIZED PLATE
WASHER
BOLT DIAMETER + 316"x13
4" LONGDIAGONALLY SLOTTED HOLE HOLECENTERED IN PL
14" GALVANIZED PLATE
WASHERPROVIDE STANDARD CUT
WASHER BETWEEN PLWASHER & NUT
3"
3"
NOTE:1. CONTRACTOR MAY USE PLATE
WASHER OPTION A OR B2. PLATE WASHER MUST BE HOT
DIPPED GALVANIZED3. STANDARD CUT WASHER
REQUIRED BETWEEN PLATEWASHER & NUT
4. ONLY REQUIRED AT SHEARWALLS
NOTE:1. CONTRACTOR MAY USE PLATE
WASHER OPTION A OR B2. PLATE WASHER MUST BE HOT
DIPPED GALVANIZED3. STANDARD CUT WASHER NOT
REQUIRED4. ONLY REQUIRED AT SHEAR
WALLS
WALL STUDSPER PLAN
WALLSHEATHING PER
PLAN
12" MAX
FROM WALLSHEATHING TYP
ANCHOR BOLTPER PLAN
FOUNDATIONPER PLAN
2x SILL PL
PL WASHER PER3a & 3b/S4.10
A-A
AA1
2" MAXFROM WALL
SHEATHING TYP
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s410
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:17
am
FOUNDATIONDETAILS
SCALE:
12S4.111"=1'-0"
11-T226SCALE:
13S4.111"=1'-0"
11-T226
SIZE & REINF.SEE PLAN FOR
3"CLR
2"(4) #4 x
DOWELS 8"
ROUGHENED SURFACE
(2)-#3 HOOPS @ TOP & #3 TIES@ 8" O.C. @ REST OF PIER
SEE
PLAN18
" MIN
4" RAISED CONCRETEPOST BASE 6"x6"
CONCRETE PIERPER ARCH
2" CLR TYP
BRICK VENEER PERARCH
51 2"3"
11 2"
SIMPSON AP66K-38 W/ (4) 5 8"Ø
x 6" HDD STUDS
CL
POST
&FO
OTI
NG
1'-4
" PER
AR
CH
EXTERIOR SLABON GRADE
PRECAST CONCRETECAP PER ARCH
POST PER PLAN
PL 3 8"x6"x6" W/ (4) 58"DIA x 10"
HDD STUDS @ 3" GAGE EA WAY
PL 3 8"x3" x AS SHOWNW/ (2) 3 4" DIA A307
THRU BOLTS (HOTDIPPED GALVANIZED)
1/4
NOTE:HOT DIP GALVANIZEPOST BASE & BOLTS
CONTRACTOR OPTION:REPLACE CAST-IN A.B. W/ EITHER:1
2" DIA. A307 THREADED ROD EPOXY EMBED 6" MIN W/SIMPSON SET-XP EPOXY.
12" DIA. SIMPSON STRONG-BOLT 2 WEDGE ANCHOR.
4"
6"
SEE PLAN FOR SIZE & REINF
3"
CLR
2x PT SILL PL W/ 12"∅ AB (7" EMBED)@ 48" OC (SILL PL IN CONTACT W/
CONCRETE TO BE PT)
AIR GAP & BRICKVENEER PER ARCH
PRECAST PERARCH
11
11 4"
6"
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s411
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:17
am
FOUNDATIONDETAILS
SCALE:
1S5.101"=1'-0"
11-T226SCALE:
2S5.101"=1'-0"
11-T226
SCALE:
5S5.101"=1'-0"
11-T226SCALE:
6S5.101"=1'-0"
11-T226SCALE:
7BS5.101"=1'-0"
11-T226SCALE:
8S5.101"=1'-0"
11-T226
SCALE:
9S5.101"=1'-0"
11-T226SCALE:
10S5.101"=1'-0"
11-T226SCALE:
11S5.101"=1'-0"
11-T226SCALE:
12S5.101"=1'-0"
11-T226
SCALE:
3S5.101"=1'-0"
11-T226SCALE:
4S5.101"=1'-0"
11-T226
ROOF SHEATHING
NAILS @ 6" OC (EDGENAILING)
2x SOLID BLOCKING
EDGE NAILING (SEESHEAR WALL
SCHEDULE)WALL SHEATHING
2x STUD WALLSTUDS @ 16" OCUNLESS NOTED
OTHERWISE
CONTINUOUS DOUBLE 2xTOP PLATE PER 7/S5.10
SIMPSON H1 CLIPAT EACH TRUSS
MANUFACTUREDTRUSSES
11
CEILING LINE
DOUBLE TOP PLPER 7/S5.10
EDGE NAILING
8d @ 6" OC
GABLE END TRUSS W/ VERTS @ 24"OC MIN PROVIDE 7/16 APA RATED
SHT'G W/ 8d NAILS @ 6" OC EDGES &12" OC FIELD
2x6 TOP CHORD LET-IN 2x6OUTLOOKER
8d @ 6" OC
2x6 OUTLOOKER @24" OC
8d @ 6" OC
ROOFSHEATHING
PER PLAN
2x BLOCKING (MATCHDEPTH OF TRUSS TOP
CHORD) W/ (4)-8d NAILS
2x4 KICKER @ 48" OC NAILW/ (5)-16d @ TOBLOCKING
PRE MANUF ROOFTRUSS @ 24" OC
2x4 @ 4'-0" OC W/ (2) 16d NAILS@ EACH KICKER IF KICKERLENGTH EXCEEDS 6'-0"
BALLOON FRAMEEND WALL TOCEILING LINE
SIMPSON LTP4 @ 48" OC MIN
SIMPSON A23CLIP @ EACHKICKER
11
CEILING LINE
DOUBLE TOP PLPER 7/S5.10
EDGE NAILING
8d @ 6" OC
GABLE END TRUSS W/ VERTS @ 24"OC MIN PROVIDE 7/16 APA RATED
SHT'G W/ 8d NAILS @ 6" OC EDGES &12" OC FIELD
2x8 TOP CHORD LET-IN 2x4OUTLOOKER
8d @ 6" OC
2x4 OUTLOOKERPER PLAN
8d @ 6" OC
ROOFSHEATHING
PER PLAN
2x BLOCKING (MATCHDEPTH OF TRUSS TOP
CHORD) W/ (4)-8d NAILS
2x4 KICKER @ 48" OC NAILW/ (5)-16d @ TOBLOCKING
PRE MANUF ROOFTRUSS @ 24" OC
2x4 @ 4'-0" OC W/ (2) 16d NAILS@ EACH KICKER IF KICKERLENGTH EXCEEDS 6'-0"
BALLOON FRAMEEND WALL TOCEILING LINE
SIMPSON LTP4 @ 48" OC MIN
SIMPSON A23CLIP @ EACHKICKER
SIMPSON LUSHANGER EA
OUTLOOKERTO TRUSS
RIDGE BLKG W/ RIDGE VENT
RIDGE BLKG
PRE MANUFACTUREDROOF TRUSSES
2x SHAPED BLOCKING @RIDGE (ALTERNATE
BLOCKING EACH BAY)ROOF SHEATHINGPER PLAN
EDGE NAILING
PRE MANUFACTUREDROOF TRUSSES
2x BLOCKING
ROOF SHEATHINGPER PLAN
EDGE NAILING
RIDGE VENT-SEE ARCH
2x6 OVERFRAMING POSTDOWN TO FRAMING BELOW@ 48" OC MAX W/ 2x4
2x CONT FLAT TO RECEIVEBRACING/POST DOWNOF OVER FRAMING(TYP) W/ (2) 16d NAILS @ EATRUSSROOF TRUSS
PER PLAN
(2) 16d TOENAILS TO FLAT2x-TYP
2x8 FLAT W/ (3) 16d NAILS TOEACH TRUSS
8d @ 6" OC
BID ALTERNATE:TRUSS MFR PROVIDE TRUSSED OVERFRAMING@ 24" OC CLIPPED TO MAIN ROOF TRUSSES W/SIMPSON VTCR @ 48" OC IN LIEU OF 2x6OVERFRAMING & POST & 2x FLAT.
TOP PLATE SPLICE
LESS THAN 4'-0"
4'-0" MINIMUM
W/ (10) 16d NAILS AS SHOWN (EQ SPACED)
CONTINUOUSDOUBLE TOP PL
2x STUDS
16d NAILS @ 8" OCSTAGGERED (TYP)
SIMPSON LSTA36 STRAPCENTERED ON ALL DBLTOP PL SPLICES (TOP &BOTTOM PLATES)
2x STUDS
SCALE:
7AS5.101"=1'-0"
11-T226
ROOF SHEATHINGPER PLAN
12" MAX3'-0" MAX
OPENING WIDTHTRIMSTUD
SILL PL'S
SILL PL
SIMPSON A35 AS SHOWN(NOT REQ'D FOR OPENINGWIDTHS LESS THAN 6'-0")TYP
DOUBLE TOP PL
HEADER
(2) 16d FACE NAILS @16" OC - TYP @ BUILT
UP STUDS @ OPENING
FILLER STUDS ASREQ'D
(8) 16d NAILS TOHEADER - TYPEA SIDE
CRIPPLESTUD
8d NAILS @ 6" OC TODRAG TRUSS
PRE MANUF ROOFTRUSSES, SEE PLAN FOR
TYPE & SPACING
CONTINUOUSPLYWOOD ROOFSHEATHING
EDGE NAIL (8d@ 6" OC)
2x CONT BLOCKING BETWEENTRUSSES W/ 16d NAILS @ 8"
OC TO DRAG TRUSS
SIMPSON H1 CLIP @EACH TRUSS
CONT DOUBLE TOP PLSEE DETAIL 7/S5.10 FOR
SPLICE CONN.
2x STUDS PER PLAN
SHEAR WALLEDGE NAILING
DRAG TRUSSPER PLAN
SIMPSON LTP4 @ 48"OC DRAG TRUSS TOSHEARWALL UNO
PRE MANUF ROOFTRUSSES, SEE PLANFOR TYPE & SPACING
ROOF OVERFRAMINGPER 6/S5.10
TRUSSES &CONNECTIONTO WALL PERDETAIL 8/S5.10
CEILING LINE
CEILING LINE
BEAM PER PLAN
TRUSSES &CONNECTIONTO WALL PERDETAIL 8/S5.10
CEILING LINE
BEAM PER PLAN
STUD WALLPER PLAN
CONT DBLTOP PL
SIMPSON LSTA36 STRAP
SIMPSON BC POST CAP
POST - SEE PLAN
GL BEAM PER PLAN
DBL KING STUDS MIN
ROOF SHEATHING
NAILS @ 6" OC (EDGENAILING)
2x SOLID BLOCKING
EDGE NAILING (SEESHEAR WALL
SCHEDULE)WALL SHEATHING
2x STUD WALLSTUDS @ 16" OCUNLESS NOTED
OTHERWISE
CONTINUOUS DOUBLE 2xTOP PLATE PER 7/S5.10
SIMPSON H1 CLIPAT EACH TRUSS
11
KICKER PERDETAIL 3/S5.10
HANGER BYTRUSS MANUF
2x4 BLOCKING @ KICKERW/ SIMPSON LU24 EA ENDTO TRUSS
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s510
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:17
am
FRAMINGDETAILS
20S5.11
14S5.11
15S5.11
18S5.11
19S5.11
51 8x6
CO
MBS
2 G
L
5 18x9 COMB 2 GL TOP CHORD
51 8x9 COMB 2 GL TOP CHORD
518x12 COMB 2 GL
CEILING BEAM
TYP (2)
TYP (2)
BC
(2) SIMP LS70 -TYP EA POST
CONT DBLTOP PL
SIMP LSTA36 STRAP@ WALL RIDGE
(2) 2x6KINGS W/
2x6 CRIPPLE
(2) 2x6 KINGS W/2x6 CRIPPLE
6x8 DF#2 6x8 DF#2 6x8 DF#2
6x8 DF#2
6x6 DF#1
6x6 DF#1
(1) SIMPSON A35(ONE TOP) -TYP EA
END EA HEADER
SIMPSON HUCHANGER - TYP
(6)SIMP A35 -TYP SILL TOPOST
SIMP A35 -TYP
PURLINS & TRUSSPER PLAN
BALLOONFRAMED STUDSPER PLAN
ROOF TRUSSESPER PLAN
GIRDER TRUSSPER PLAN
(2) 16d NAILSTRUSS TO EA STUD
CONT DBLTOP PL
AIR GAP & BRICKVENEER PER ARCH
SCALE:
13S5.111"=1'-0"
11-T226SCALE:
14S5.111"=1'-0"
11-T226
SCALE:
17S5.111/4"=1'-0"
11-T226SCALE:
18S5.111"=1'-0"
11-T226SCALE:
19S5.111"=1'-0"
11-T226SCALE:
20S5.111"=1'-0"
11-T226
SCALE:
21S5.111/4"=1'-0"
11-T226SCALE:
22S5.111"=1'-0"
11-T226SCALE:
23S5.111/2"=1'-0"
11-T226
SCALE:
15S5.111"=1'-0"
11-T226SCALE:
16S5.111"=1'-0"
11-T226
GL TRUSS PER PLAN
ROOF SHEATHINGOVER T&G DECKINGPER PLAN
PURLIN PER PLAN
SIMPSON HL35 EA. SIDE OF PURLIN W/(2) 12" DIA THRU BOLTS TO PURLIN & (2)1
2" DIA x 4" LAG BOLTS IN BEAM (EA.ANGLE)
GL TRUSS PER PLAN
ROOF SHEATHING OVER T&GDECKING PER PLAN
ROOF SHTH OVER T&GDECKING PER PLAN
GL TRUSS PER PLAN
ROOF SHEATHINGOVER T&G DECKINGPER PLAN
RIDGE BEAM PER PLAN
CONT. 3x6 RIPPED RIDGEFILLER BLOCK
RIDGE BEAM PER PLAN
GL TRUSS PERPLAN
CONT. 3x4 RIPPED RIDGEFILLER BLOCK
212"
2"TYP
PLs 14"x314"x31
4"x5" LONG EA SIDEOF PURLIN W/ (2) 12" DIA THRUBOLTS TO RIDGE & (2) 1
2" DIAx4"LAG BOLTS IN BEAM (EA ANGLE)
114"
TYP
2"
BEAM PER PLAN
518" GL CONT BLKG W/ (2) SIMPSON
SDS 14x5" SCREWS @ 10" OC & 4"FROM EA END (DAP SCREWS INTOBLKG)
2x FASCIA PERARCH
ROOF SHEATHING PERPLAN OVER T&G DECKING
3"3"
3"
3"
2" 2"
6"
112"
POST
CL OF POST
TOP CHORD OFTRUSS
14" SIDE PLs W/ 3
4" DIA A307THRU BOLTS
4"3"
11 2"
2"2"
14" SIDE PL W/(5) 3
4"DIA THRU-BOLTS
CEILING BEAM OF TRUSS
6"
4"2"
2"2"
2"2"
2"
2" 4" 2"
CL OFBEAM
CL OF
BEAM
POST PERPLAN
CEILING BEAMOF TRUSS
14" SIDE PLs W/ 3
4" DIAA307 THRU BOLTS
TOP CHORD OFTRUSS
BEAM PER PLAN
SIMPSON CCT 514-6
8"
GABLE END TRUSS &KICKERS PER 3/S4.10
ROOF SHEATHINGPER PLANROOF SHEATHING OVER T&G
DECKING PER PLAN
PURLIN PER PLAN
2x8 TOP CHORD
SIMPSON LUSHANGER
2x STUDS @ 16" OC UNOSHEARWALL SHEATHING PER
PLAN & SHEARWALL SCHEDULE
CONT DBL TOP PL
L4x4x14 LINTEL ANGLE.
BEAR ON BRICK VENEER 6"MIN. EA END
BALLOON FRAMEDSTUDS PER PLAN
AIR GAP & BRICKVENEER PER ARCH
6x10 HEADER
114" 11
4"
11 2"4"
11 2"11 2"
112" 6" 6" 11
2"
CL BEAMCL BEAM
PERMIT SET
WASHINGTON CO., OREGONSTEED CREEK CLUBHOUSE
1 2 3 4 5
THESE DRAWINGS ARE THE PROPERTY OFMYHRE GROUP ARCHITECTS AND ARE NOTTO BE REPRODUCED IN ANY MANNER,EXCEPT WITH THE PRIOR WRITTENAPPROVAL OF MYHRE GROUP ARCHITECTS
MYHRE GROUP ARCHITECTS, INC.C
C
B
A
D
REV
JOB NO:
DATE:
DRAWN BY:
ASSOC:
JC:
DATE FILE
PM:
808 SW 3rd Avenue, Suite 500 Portland, Oregon 97204t 503.236.6000 f 503.236.7500 www.myhregroup.com
K. RANDOLPH
090550
25 JAN 2012
P. STEWART
Portland: (503) 624-7005 Bend: (541) 383-1828Froelich-Engineers.com
Xref
s: 1
1-t2
26xt
b T
B090
550-
24x3
6 fr
oelic
h-lo
goP:
\201
1job
s\11
-T22
6 (S
teed
Cre
ek -
Clu
bhou
se)\S
truct
ural
\Cur
rent
\11-
t226
s511
.dw
g
Dat
e Pl
otte
d: 2
5 Ja
n 20
12 -
9:17
am
FRAMINGDETAILS