Statutory regulation
Transcript of Statutory regulation
-
8/13/2019 Statutory regulation
1/19
-
8/13/2019 Statutory regulation
2/19
Statutory regulations
A statuteis a lawmade by legislativebodies
and regulationsissued by government
agencies
These are the common laws of state or central
government which has to be followed by
client as well as contractor before starting
industrial project.
These are as follows
http://en.wikipedia.org/wiki/Lawhttp://en.wikipedia.org/wiki/Legislaturehttp://en.wikipedia.org/wiki/Regulationshttp://en.wikipedia.org/wiki/Regulationshttp://en.wikipedia.org/wiki/Legislaturehttp://en.wikipedia.org/wiki/Law -
8/13/2019 Statutory regulation
3/19
CONTENTS
CHIEF CONTROLLER OF EXPLOSIVE(CCOE)
OIL INDUSTRY SAFETY DERECTORATE(OISD)
INDIAN BOILER REGULATION(IBR)
POLUTION CONTROL BOARD(PCB)
-
8/13/2019 Statutory regulation
4/19
STATE INDUSTRIAL DEVELOPMENT
CORPORATION(SIDC)
TRAFFIC ADVISORY COMMITTEE(TAC)
DIRECTOR GENERAL OF CIVIL
AVIATION(DGCA)RULE
INDIAN ELECTRICITY RULES.
-
8/13/2019 Statutory regulation
5/19
CCOE
These are statutory rules and a central Govt.
authority for whole of India.
All liquid hydrocarbon which are catagorised
in classes A, B, C. are required to be stored as
per these rules.
Rules are based on flammable and non
flammable liquids as per there flash points.
-
8/13/2019 Statutory regulation
6/19
The liquid coming under CCOE preview can
also be stored in underground tanks. But there
are not written rule available from CCOE for
this types of installation.
The general consideration is the tank edge to
fence distence can be 2-3 m. preferable to
keep 4.5m.
-
8/13/2019 Statutory regulation
7/19
The storage are required to be located at
certain minimum distance from other plant
facilities as per regulations. The CCOE will not
approve installation which are not located at
minimum distance from other facility.
The dyke wall are necessary according to
these rules which rounds the tank farm tosecure the liquid flowing in case.
-
8/13/2019 Statutory regulation
8/19
OISD
These rules not statutory and hence notmandatory. However, these have to be followed ifrequired by client.
These rule cover process plant, utility and of site,all storage of all type of plants including LPGstorage and flammable storage.
For the choice b/w OISD rule and other rules, theclient should involve as the OISD are more
stringent and hene require more space for thestorage
Using this rule means going to the SAFER SIDE.
-
8/13/2019 Statutory regulation
9/19
For LPG installation it has become a general
practice in india to follow OISD rule as the
distance required of these rules are generally
more than the petrolium (CCOE) rule.
As per the conventional practice in the oil
industry in india OISD have to be followed for
all crude oil refinery layout.
-
8/13/2019 Statutory regulation
10/19
IBR
This rules are statutoryand hence mandatory
of central Govt. but the admin. Of the rule is
at the state level. There is a separate IBR
authority for each state located in its capital.
installation of all steam pipeline(above 10size,
3.5bar pressure, 22.5litre) are required to be
approved by the IBR authority of respectivestate.
-
8/13/2019 Statutory regulation
11/19
The IBR equipment and IBR piping itemsmanufectured in a particular state shall beapproved by IBR authority of that state. The
installation shall also be approved by the same.All dispute in this regard have to be referred tocentral boiler board located in Delhi.
Fabrication and installation of piping coming
under this preview shall not be started unlessconstruction drawing and other document areapproved by the state IBR authority.
-
8/13/2019 Statutory regulation
12/19
PCB
These rules are statutory in nature and hencehave to be followed.
All concern of this rule is to make comfort and
save of human, animal, plants. the liquid effluent should be discharged to
the effluent collection system leading to
effluent treatment plant . None of theeffluent shall ever be discharged to stormwater drains.
-
8/13/2019 Statutory regulation
13/19
The height of the flare and the safety zone
around it shall be decided by process licensor
to suit the requirement of state pollution
board.
The pilot panel for flare shall be located
outside the safety cone of the flare.
-
8/13/2019 Statutory regulation
14/19
SIDC
These rule have been accorded the status ifstatutory rule by central Govt. and hence aremandatory. These rule govern the following.
The greenbelt required around the plantwithin the plot.
The requirement of the free space in the plant
area. The distance of plant from the adjacent
highway, main road and human settlements.
-
8/13/2019 Statutory regulation
15/19
Fire safety provision for the plant.
Drainage facility for the plant.
The size of water storage inside the plantrequired approval of the SIDC if water is
drawn from SIDC main.
This rule require to provided the parking
inside the plant due to high traffic.
-
8/13/2019 Statutory regulation
16/19
TAC
This rule is non-statutory in nature
Even though this rule in non mandatory, it is
essential to follow these strictly in layout as
the insurance premium charged by the
insurance company.
-
8/13/2019 Statutory regulation
17/19
-
8/13/2019 Statutory regulation
18/19
If the plant site is near the airport it is
mandatory to obtain DGCA prior approval for
locating the plant on that area
-
8/13/2019 Statutory regulation
19/19
USE OF THESE RULES AND
REGULATIONS.
It is important to find out which rule areapplicable to the particular plant area.
The work shall be carried out by actual
reference to the latest rules/regulation. In case of dispute b/w statutory and other
rules. The statutory rule shall be always
govern. However more stringent of the twoshall prefer. Always keep safety in mind.
THANKS.