Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study...
-
Upload
leon-lewis -
Category
Documents
-
view
214 -
download
1
Transcript of Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study...
![Page 1: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.](https://reader036.fdocuments.in/reader036/viewer/2022082817/56649e455503460f94b39735/html5/thumbnails/1.jpg)
Status of the Data Collection
• Completed– State and Agency Surveys– Indoor Air Quality Study– Bulk Fuels Study– Large Multi-family Buildings Study
• In Progress– Utility Bill Collection– National Occupant Survey– National Weatherization Staff Survey– Weatherization Training Center Survey
![Page 2: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.](https://reader036.fdocuments.in/reader036/viewer/2022082817/56649e455503460f94b39735/html5/thumbnails/2.jpg)
Status of the ARRA Evaluation
• Evaluation Plan is complete. – One more round of surveys and utility data
collection, focus on PY10– Targeted evaluations of WIPP and SERC– Other studies: persistence of energy savings,
assessment of under- and over-performers, social network analysis
• Information Collection Request has been submitted to OMB for approval. Projecting an early winter start date for data collection.
![Page 3: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.](https://reader036.fdocuments.in/reader036/viewer/2022082817/56649e455503460f94b39735/html5/thumbnails/3.jpg)
Indoor Air Quality Findings
• Carbon Monoxide– No homes exhibited peak ambient CO problems
• Radon– 4% of site-built homes went from below EPA
threshold (4 pC/L) pre-wx to above post-wx• Formaldehyde– Net increase of 5.1 ppb post-wx in mobile homes
• Temperature – Virtually no change in settings post-wx
![Page 4: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.](https://reader036.fdocuments.in/reader036/viewer/2022082817/56649e455503460f94b39735/html5/thumbnails/4.jpg)
Occupant Survey Findings*
• Occupants’ reported home temps– Winter: 51% comfortable; 36% cold; 9% very cold– Summer: 62% comfortable; 25% hot; 8% very hot
• Occupants’ report health– Asthma: 21% reported; of these 11% ER visits last
12 months– Physical health not good last 30 days: 45%– Mental health not good last 30 days: 34%
* From IAQ Study
![Page 5: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.](https://reader036.fdocuments.in/reader036/viewer/2022082817/56649e455503460f94b39735/html5/thumbnails/5.jpg)
Diagnostic procedure (PY08) Percentage of agencies that performed
Blower door (house air leakage rate) 99%CO measurements in flues (space heating system) 91%CO measurements in flues (water heating system) 88%Flue gas analysis (space heating sys. steady-state eff. test) 83%Cooking stove 82%Draft/spillage (space heating system, normal operation) 78%CO measurements in living areas 78%Draft/spillage (water heating system, normal operation) 77%Flue gas analysis (water heating steady-state eff. test) 72%CO measurements in equipment rooms 69%Worst case draft/spillage (CAZ) 63%Refrigerator energy use 63%Duct pressure pan measurements 59%Zonal pressure measurements 58%Heat rise measurements (space heating system) 55%Infrared scanning (camera) 51%
Program Characterization Findings
![Page 6: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.](https://reader036.fdocuments.in/reader036/viewer/2022082817/56649e455503460f94b39735/html5/thumbnails/6.jpg)
• Air Sealing - ~95% (e.g., 90% bypass sealing, 75% general caulking, 35% duct sealing)
• Insulation - ~75% units (e.g., 70% attic, 25% wall, 20% floor)• Hot Water Measures – 60% units (e.g., 40% pipe insulation, 9% replacement)• Energy Efficient Lights -- ~60%• Furnace Work -- ~45% units {20% tune-up, 20% new system, 10% repair}• Windows – 40% units (e.g., 20% new, 20% glazing, 10% repairs)• Doors – 35% units • Health & Safety – 80% units
• CO monitor – 55%• Smoke Alarm – 45%• Ground vapor barrier – 15% • Attic ventilation – 15%
Program Characterization Findings: Frequency of Measures Installed (PY08)
![Page 7: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.](https://reader036.fdocuments.in/reader036/viewer/2022082817/56649e455503460f94b39735/html5/thumbnails/7.jpg)
Projected Publication Dates
• National Energy Savings Estimates – PY07 & 08: Dec. 2011
• Program Characterization – PY 08: Dec. 2011• IAQ Winter and Summer Studies: Dec. 2011• Program Eligibility – PY08: Feb. 2012• National Occupant Survey – Pre-WX: Feb. 2012• Case Studies – March 2012• Field Process Study – March 2012