7
Status of the Data Collection • Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study • In Progress – Utility Bill Collection – National Occupant Survey – National Weatherization Staff Survey – Weatherization Training Center Survey

Transcript of Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study...

Page 1: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.

Status of the Data Collection

• Completed– State and Agency Surveys– Indoor Air Quality Study– Bulk Fuels Study– Large Multi-family Buildings Study

• In Progress– Utility Bill Collection– National Occupant Survey– National Weatherization Staff Survey– Weatherization Training Center Survey

Page 2: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.

Status of the ARRA Evaluation

• Evaluation Plan is complete. – One more round of surveys and utility data

collection, focus on PY10– Targeted evaluations of WIPP and SERC– Other studies: persistence of energy savings,

assessment of under- and over-performers, social network analysis

• Information Collection Request has been submitted to OMB for approval. Projecting an early winter start date for data collection.

Page 3: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.

Indoor Air Quality Findings

• Carbon Monoxide– No homes exhibited peak ambient CO problems

• Radon– 4% of site-built homes went from below EPA

threshold (4 pC/L) pre-wx to above post-wx• Formaldehyde– Net increase of 5.1 ppb post-wx in mobile homes

• Temperature – Virtually no change in settings post-wx

Page 4: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.

Occupant Survey Findings*

• Occupants’ reported home temps– Winter: 51% comfortable; 36% cold; 9% very cold– Summer: 62% comfortable; 25% hot; 8% very hot

• Occupants’ report health– Asthma: 21% reported; of these 11% ER visits last

12 months– Physical health not good last 30 days: 45%– Mental health not good last 30 days: 34%

* From IAQ Study

Page 5: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.

Diagnostic procedure (PY08) Percentage of agencies that performed

Blower door (house air leakage rate) 99%CO measurements in flues (space heating system) 91%CO measurements in flues (water heating system) 88%Flue gas analysis (space heating sys. steady-state eff. test) 83%Cooking stove 82%Draft/spillage (space heating system, normal operation) 78%CO measurements in living areas 78%Draft/spillage (water heating system, normal operation) 77%Flue gas analysis (water heating steady-state eff. test) 72%CO measurements in equipment rooms 69%Worst case draft/spillage (CAZ) 63%Refrigerator energy use 63%Duct pressure pan measurements 59%Zonal pressure measurements 58%Heat rise measurements (space heating system) 55%Infrared scanning (camera) 51%

Program Characterization Findings

Page 6: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.

• Air Sealing - ~95% (e.g., 90% bypass sealing, 75% general caulking, 35% duct sealing)

• Insulation - ~75% units (e.g., 70% attic, 25% wall, 20% floor)• Hot Water Measures – 60% units (e.g., 40% pipe insulation, 9% replacement)• Energy Efficient Lights -- ~60%• Furnace Work -- ~45% units {20% tune-up, 20% new system, 10% repair}• Windows – 40% units (e.g., 20% new, 20% glazing, 10% repairs)• Doors – 35% units • Health & Safety – 80% units

• CO monitor – 55%• Smoke Alarm – 45%• Ground vapor barrier – 15% • Attic ventilation – 15%

Program Characterization Findings: Frequency of Measures Installed (PY08)

Page 7: Status of the Data Collection Completed – State and Agency Surveys – Indoor Air Quality Study – Bulk Fuels Study – Large Multi-family Buildings Study In.

Projected Publication Dates

• National Energy Savings Estimates – PY07 & 08: Dec. 2011

• Program Characterization – PY 08: Dec. 2011• IAQ Winter and Summer Studies: Dec. 2011• Program Eligibility – PY08: Feb. 2012• National Occupant Survey – Pre-WX: Feb. 2012• Case Studies – March 2012• Field Process Study – March 2012