Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan...
-
Upload
jayda-moser -
Category
Documents
-
view
229 -
download
0
Transcript of Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan...
Star kW
Star kWStar kW
NEW
Star kW
Star kWStar kWInstantaneous wall-hung gas boilersInstantaneous wall-hung gas boilers
Conventional flue Sealed room fan assisted
NIKE Star 23 kW EOLO Star 23 kW
Star kW
New design
Compact dimensions
Easy installation
Hydraulic circuit with fast production of d.h.w.
Digital technology
Star kWStar kW
Star kW
Modern and elegant design
Pleasant insertion into any home interior
Control panel with new digital interface
New designNew design
New
design
Star kW
Height = 762 mm
Width = 450 mm
Depth = 250 mm
Compact dimensionsCompact dimensions
Star kW
Light weight = 34 kg
Only 25 cm deep
IPX4D insulation
Operation without electrical polarity
Easy installationEasy installation
Star kW
D.H
.W.
mode
Hydraulic diagramHydraulic diagram
Bithermal heat exchangerPump
Pressure switch
Automatic by-pass
D.h.w. flow switch
Main components :
Hydraulic
circuit
Star kW
Bithermal heat exchangerBithermal heat exchanger
Double function (c.h. and d.h.w.)
Domestic hot water fast production
“Pipe in pipe” copper made
Hydraulic
circuit
Star kW
D.h.w.
circuit
C. h.circuit
“Cross pipe”
“Central heating pipes collector”
Bithermal heat exchanger sectionBithermal heat exchanger sectionHydraulic
circuit
Star kW
Grundfos pumpGrundfos pump
Star kW
Highly sensitive d.h.w. magnetic flow switch
Min. flow rate = 2,5 l/min
Min. water pressure = 0,26 bar
Modulating heat output from 23,3 to 7 kW
D.h.w. circuit featuresD.h.w. circuit featuresHydraulic
circuit
Star kW
t 30°C
t 25°C
l/min
Domestic hot water flow rateDomestic hot water flow rate
0 10 20
11,1
13,3
0 10 200 10 20
11,1
13,3
Hydraulic
circuit
Star kW
Buttons
For faster and easier boiler regulations
Control panel with digital interface Control panel with digital interface
Display
Constant monitoring of functioning mode and for boiler diagnostics
Digital
technology
Star kW
D.h.w. temperatureadjustment
Digital interface buttons Digital interface buttons
C. H. temperature
adjustment
Reset button
Off/Summer/Winter button
Digital
technology
Star kW
D.h.w. mode operation
Illuminated LCD display Illuminated LCD display
C. H. mode operation
Heating power Summer mode operation
Burner ON
Boiler / d.h.w. temperature and failures codes
The display illumination is green during the normal operation and red or orange in case of faulty
Winter mode operation
Digital
technology
Star kW
Modulating for C.H. and D.H.W. by 2 NTC sensors Operation parameters setting by means buttons Operation without electrical polarity C.h. anti-cycling device Low circulation safety device Anti freeze function (protection until - 5° C) Compatible with a thermo climatic remote control (DRC)
Printed control boardPrinted control boardDigital
technology
Star kW
Boiler remote control (adjustments, display, etc) Digital weekly room thermostat Thermo regulating functions according to the
room temperature required
Thermo regulating remote controlThermo regulating remote control (CRD) (CRD)(optional)(optional) D
igital
technology
Star kW
Pre-arranged for Pre-arranged for the “BLUE serie” the “BLUE serie” concentric flue kitsconcentric flue kits and for twin pipe and for twin pipe kitskits
Flue connection and flue kitsFlue connection and flue kits
Built-in flue sampling Built-in flue sampling pointspoints
Flue
connections
Star kW
Main optionsMain options
Options
Connecting group
Digital weekly timer/room thermostat
Anti-scale kit
Star kW
23,3 kW23,3 kWMaximum heat outputMaximum heat output
9,3 kW9,3 kW
7 kW7 kW
90,9%90,9%
35 - 80 °C35 - 80 °C
35 - 55 °C35 - 55 °C
6 litres 6 litres
G20 - G30 - G31G20 - G30 - G31
IPX4DIPX4D
30 kg30 kg
Minimum central heating heat outputMinimum central heating heat output
Minimum d.h.w heat outputMinimum d.h.w heat output
Net efficiency at max heat outputNet efficiency at max heat output
Efficiency rating - according to EN 92/42Efficiency rating - according to EN 92/42
Central heating temperature rangeCentral heating temperature range
Domestic hot water temperature rangeDomestic hot water temperature range
Expansion vessel capacityExpansion vessel capacity
Type of gases Type of gases
Electrical protectionElectrical protection
WeightWeight
Main technical dataMain technical data
23,3 kW23,3 kW
9,3 kW9,3 kW
7 kW7 kW
90,4%90,4%
35 - 80 °C35 - 80 °C
35 - 55 °C35 - 55 °C
6 litres 6 litres
G20 - G30 - G31G20 - G30 - G31
IPX4DIPX4D
34 kg34 kg
NIKENIKEStar 23 kWStar 23 kW
EOLOEOLOStar 23 kWStar 23 kW