All ideas, designs, arrangements and plans indicated or represented by these drawings are owned by, and property of OHSU and Corbin Design and were created, evolved and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm or corporation for any purpose whatsoever without the written permission of Corbin Design and OHSU.
These standards apply to all OHSU facilities except for Doernbecher Children’s Hospital. For Doernbecher Children’s Hospital signage standards contact the OHSU Design and Construction department.
Table of Contents
I-2: Secondary ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
I-2a: Conference Room ID w/ Insert Holder . . . . . . . . . . . . . . .69
I-3: General Room ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
I-3a: General/Patient Room ID w/Notifier Bar . . . . . . . . . . . . . .71
I-4,a: Patient Room ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
I-5: Utility ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
I-6: Cubicle ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
I-7: Individual Letters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
I-7c: Individual Letters, Acrylic Panel . . . . . . . . . . . . . . . . . . . .76
I-9: Research Bay ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
V-1-5: Vinyl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Notifiers
N-1a,b,c,d,e,f,g: Notice Holders . . . . . . . . . . . . . . . . . . . . . . .84
N-2: General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
N-2a: General Information . . . . . . . . . . . . . . . . . . . . . . . . . . .88
N-3: General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Regulatory
Restroom Sign Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
R-1: Regulatory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93
R-1a: Regulatory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
R-2: Regulatory, Stairwell . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
R-3: Regulatory, Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
Decorative and Custom
Directory Signage Decorative, Construction Details . . . . . . . . .98
Guide Signage Decorative, Construction Details . . . . . . . . . . .99
D-2e: Main Directory, Wall-mounted, Existing Cabinet . . . . . .100
D-3: Elevator Directory, Decorative . . . . . . . . . . . . . . . . . . . .101
D-4,a: Strip Map, Decorative . . . . . . . . . . . . . . . . . . . . . . . . .102
G-1,a,b: Guide Sign, Decorative . . . . . . . . . . . . . . . . . . . . . .103
G-4a,b: Guide Sign, Custom . . . . . . . . . . . . . . . . . . . . . . . . .107
I-1,a: Primary ID, Decorative . . . . . . . . . . . . . . . . . . . . . . . . .108
I-1ca: Primary ID, Standard . . . . . . . . . . . . . . . . . . . . . . . . . .110
I-1d: Primary ID, Standard . . . . . . . . . . . . . . . . . . . . . . . . . . .111
I-8: Logo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
O-5c: Overhead Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
N-1d-alt: Notice Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
N-1h: Notice Holder w/ Brochure Holders . . . . . . . . . . . . . . .116
Table of Contents
Overview
Summary of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Style Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Interior Sign Type Array and Hanging Guidelines . . . . . . . . . . . .6
Graphic Standards & Specifications
Color & Typography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Interior Fabrication Specifications . . . . . . . . . . . . . . . . . . . . . .19
Directories
D-1: Main Directory, Freestanding w/ Handheld Map . . . . . . . .23
D-1a: Main Directory, Wall-mounted w/ Handheld Map . . . . . .25
D-2: Main Directory, Freestanding . . . . . . . . . . . . . . . . . . . . . .27
D-2a: Main Directory, Wall-mounted . . . . . . . . . . . . . . . . . . . .28
D-2b: Main Directory, Freestanding, Angled . . . . . . . . . . . . . .29
D-2d: Main Directory, Freestanding, Tall-angled . . . . . . . . . . . .31
D-2c: Main Directory, Wall-mounted . . . . . . . . . . . . . . . . . . . .33
D-2f: Main Directory, Wall-mounted . . . . . . . . . . . . . . . . . . . .35
D-3a: Elevator Directory, Standard . . . . . . . . . . . . . . . . . . . . . .36
D-3b,c,e,f,g: Elevator and Physician Directory . . . . . . . . . . . . .37
D-4b,c: Strip Map, Standard . . . . . . . . . . . . . . . . . . . . . . . . . .42
D-5: Building/Floor Transition Sign, Wall-mounted . . . . . . . . . .43
Guides
G-2,a,b: Guide Sign, Standard . . . . . . . . . . . . . . . . . . . . . . . . .45
G-3: Guide Sign, Freestanding . . . . . . . . . . . . . . . . . . . . . . . . .48
Overheads
O-1a,b: Overhead, Projecting ID/Guide . . . . . . . . . . . . . . . . . .50
O-1c,d: Overhead, Projecting ID/Guide . . . . . . . . . . . . . . . . . .51
O-1e,f: Overhead, Projecting ID/Guide . . . . . . . . . . . . . . . . . . .52
O-1g,h: Overhead, Projecting ID/Guide . . . . . . . . . . . . . . . . . .53
O-2,a: Overhead ID/Guides . . . . . . . . . . . . . . . . . . . . . . . . . . .54
O-3,a: Overhead Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
O-4a,b: Overhead, Projecting ID/Guides, Large . . . . . . . . . . . .57
O-5,b: Overhead Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
O-6,a: Overhead ID/Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Identifiers
I-1b: Primary ID, Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
I-1c: Primary ID, Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
I-1e: Primary ID, Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
2
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Summary of Changes
The goal should always be to implement signs that are already in the standards, although minor changes are often required as new challenges present themselves. This page is provided to help users of the standards stay up to date with revisions that have been made over time. Any changes or deviations to these standards must be reviewed and approved by the Wayfinding Committee.
The following is a summary of changes to the standards by date:
6/2013 • Original Standards Implemented
6/12/2019 • Completely updated standards
3
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
OHSU Style Guidelines
Making a list and getting it rightBulleted lists:• Include periods after bulleted items if those items are clauses
or long phrases, or if they are short phrases that complete the statement introducing them. Do not use periods if the items resemble a shopping list, regardless of whether they complete the introductory statement.
• Capitalize the first letter of each item in a bulleted list.
• Do not use semi-colons after each bulleted item.
Commas: Do not use an Oxford comma in a simple series but do include it in a complex series. He ate peas, carrots and celery. Not peas, carrots, and celery. The meal consisted of a roasted turkey that was stuffed with feta cheese and pine nuts, baked sweet potatoes with thyme, and a Brussels sprouts side dish.
Upper or lower: Take it case by caseColons: Capitalize the first word after a colon if the word starts a complete sentence: Then he made a promise: The research results will be available to scientists worldwide within 12 months.
Departments are capitalized when referring to their proper names, but not in faculty titles referencing the specialty: It’s the Department of Pediatrics but Elisha DuBois, M.D., chairman of pediatrics.
Professional title: Capitalize when a formal title directly precedes a name: OHSU President Joe Robertson, M.D. Do not capitalize when set off from the name by punctuation: OHSU’s president, Joe Robertson, M.D., and Joe Robertson, M.D., president of OHSU. And don’t capitalize an informal title: ICU nurse Jane Smith. Capitalize chairman, chairwoman as a formal title before a name: department Chairman, Henry Ford, committee Chairwoman Margaret Chase Smith.
Do not capitalize a casual, temporary position: meeting chairman Robert Jones. Use chairperson, chair or co-chair as preferred by your program or department.
A title with a signature on letterhead is the exception to the above guidelines: Joe Robertson, M.D., President.
Capitalize book titles and the names of newspapers and magazines. Include magazine, journal, etc. lowercase and without italics unless it’s part of the publication’s formal name: Harper’s Magazine, Time magazine, the journal Nature. See the composition titles section of the AP Stylebook for further clarification.
Headings and subheadings: Wondering where to use capitals in a document? The table below provides some answers.
These guidelines adhere to AP style as a first reference and Webster’s dictionary as a secondary source. The below categories touch upon common questions and issues but do not represent a full list. For more information, visit apstylebook.com.
A, b, c, d, Ph.D.Periods are always used when abbreviating academic degrees and certifications: B.S., F.A.A.N., M.S., M.D., Ph.D., R.N., D.D.S., etc. Even when an acronym/degree is long or unwieldy, the punctuation is still retained: P.A.-C. (AP Style makes an exception for MBA where periods are not used. These style guidelines do not follow that exception for consistency and to avoid confusion.)
These guidelines do not apply when titles are included in databases where space is constrained, or for vinyl signage applications, as vinyl punctuation is easily vandalized.
Location, location, locationWhen directing to a location: First give context as to which part of town the visitor will need to navigate. Identify the campus first, followed by the parking garage, building name, elevator location, floor number and final destination.
When using postal delivery:
OHSU Vein Clinic Mail code: L492 3181 S.W. Sam Jackson Park Road Portland, OR 97239-3098
When directing to a website: Use a link rather than giving a URL, as in Read more about deep brain stimulation at OHSU, with the link directing to the appropriate site. It is preferred that websites referenced in printed materials do not include http:// at the beginning of the URL except in those instances where navigation to a site requires it. Visit us at www.ohsu.edu. Always test URLs before use to be sure they are valid.
And and &Use an ampersand when it is part of a company’s formal name or composition title: House & Garden, Procter & Gamble, Wheeling & Lake Erie Railway. The ampersand should not otherwise be used in place of and.
For certain circumstances OHSU units may be granted approval to use their unit name along with the OHSU master logo. In those instances where the name is very long an ampersand can be used to replace and. However, uses in text always require spelling out and.
This Heading Is in Title Case. Capitalize the principal words, including verbs, prepositions and conjunctions of four letters or more.
This heading is in sentence case. Only the first word is capitalized.
Title of a document or website: NICU Services at Doernbecher, The Economic Impact of OHSU
Subhead within a document, website, publication such as brochure, poster or newsletter: Find a provider, Infants younger than six months, OHSU community service
Titles in publications, such as a brochure, poster, newsletter or magazine titles: You and Your Baby at Doernbecher, Community Connections, OHSU At a Glance
Headlines in press releases: OHSU cures cancer once and for all.
Lecture titles: The 24-Hour Clock in Human Health, The Promise of Gene Therapy
All sentences within body copy, regardless of whether they are online or printed.
Although AP Stylebook does not stipulate within its guidelines where title or sentence case is used, the guidelines above represent the examples AP provides in the layout of its printed and online guides.
Make a date to check the timeThere’s more to know than how many days are in each month. Capitalize every month in all uses. When a month is used with a specific date, abbreviate only Jan., Feb., Aug., Sept., Oct., Nov. and Dec. Spell out months when using alone, or with a year alone: The lectures will be held Feb. 16 and March 22 this year.
When listing time of day: 11:30 a.m., 11 a.m. (not 11:00), 12 p.m. or noon, (never 12 noon). AP Stylebook encourages noon over 12 p.m.
Don’t carry the abbrevs. too farIn general, avoid alphabet soup. Do not use abbreviations or acronyms that the reader would not quickly recognize and do not use abbreviations or acronyms in headings and titles.
Do not follow the name of a program or other formal nouns with an abbreviation or acronym in parentheses or set off by dashes. If an abbreviation or acronym would not be clear on second reference without this arrangement, do not use it. Names not commonly before the public should not be reduced to acronyms solely to save a few words.
Correct: The Center for Typed Words was formed to enlighten the public about printed communications. The center has many members.
Incorrect: The Center for Typed Words (CTW) was formed to enlighten the public about printed communications.The CTW has many members.
Do not abbreviate department and specialty names. For example, use: Hematology and Medical Oncology not Hem Onc. Use Obstetrics and Gynecology not OB GYN.
When composing posts for social media, adhere to the style guidelines with the exception of posting to twitter. Due to the character limit set by the platform, it’s acceptable to use abbreviations, use figures for numbers below 10 and use an ampersand instead of and. If your post requires more than one tweet to communicate the message, end each tweet with 1/3, 2/3, 3/3, etc. This will show readers each tweet is a part of a longer message.
Do you take one or two words with your health care?Two words, except in the use of a formal noun, as in Tuality Healthcare or OHSU Healthcare.
4
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Make your numerals countSpell out whole numbers below 10. The Yankees finished second. He had nine months to go.
Use figures for 10 or above and whenever preceding a unit of measure or referring to ages of people, animals, events or things, and also, in all tabular matter, and in statistical and sequential forms. The law is 8 years old; the 101-year-old house.
Some exceptions to the below-10 rule: Ages, weights, millions and billions (except casual uses), percentages and currency: My 8-year-old daughter, who weighs 9 pounds, just inherited $3 million from her aunt. A week ago she had about 5 cents to her name. I asked her to lend me a thousand at 6 percent, and she said she’d think about it.
At the start of a sentence: Forty years was a long time to wait. Fifteen to 20 cars were involved in the accident. The only exception is years: 1992 was a very good year.
Calling all hyphensPhone listings: Use hyphens after area code and prefix. Do not use parentheses around area code. For example: 503-494-8311.
An em dash ( — ) with a space on either side is used to indicate an abrupt change in thought or an emphatic pause in a sentence.
A hyphen ( - ) is a word joiner. Use it to avoid ambiguity or to form a single idea from two or more words.
---
Questions? Contact Brand Strategy in Marketing and Communications at [email protected]
5
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
D-1 Main Directory, Freestanding, w/Handheld Map D-2 Main Directory, Freestanding
D-2c Main Directory, Wall-mounted, Simplified D-2f Main Directory, Wall-mounted, Simplified
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S
D I R E C T O R YD I R E C T O R Y
S A M J A C K S O N H A L L • M A R Q U A M H I L L C A M P U S
D I R E C T O R YD I R E C T O R Y
B A I R D H A L L • M A R Q U A M H I L L C A M P U S
D-1, D-1a, D-2, D-2a-fLocated near building entrances or at transition points between connecting buildings, these freestanding or wall-mounted directories provide the “universe of information” available to patients and visitors. The directory includes a listing of destinations accessible within that building, organized alphabetically into two sections, first destinations and then patient units. When connected to other buildings, there is a third section that includes instructions on how to access those other buildings. The directory also includes a map of the current floor showing public pathways and elevators.
D-2b Main Directory, Freestanding, Angled, w/Handheld Map D-2d Main Directory, Freestanding, Tall-angled
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S
D I R E C T O R YD I R E C T O R Y
H A T F I E L D R E S E A R C H C E N T E R
D-1a Main Directory, Wall-mounted, w/Handheld Map D-2a Main Directory, Wall-mounted
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S O H S U H O S P I T A L • M A R Q U A M H I L L C A M P U S
D I R E C T O R YD I R E C T O R Y
The following signs are installed 70" from the top of the sign window frame to the floor. This places important wayfinding information at a standard reading level for all visitors.
70"
7'-2"
5'-2"
3'-10"
5'-2"
6'-4 1/2"
4'-6"
3'-10"
4'-5 1/2"
5'-3"
5'-1"
2'-6"
5'-0"(max)
3'-9 5/8"
3'-7"
3'-4 1/4"
3'-7"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Directories 6
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
D-3 Elevator Directory Decorative D-3a Elevator Directory D-3b Elevator Directory, Inside Cab D-3c Elevator Directory, Inside Cab D-3e Physician Directory
D-4 Strip Map w/Guide Info, Decorative D-4a Strip Map, Decorative D-4b Strip Map w/Guide Info D-4c Strip Map D-5 Building/Floor Transition Sign, Wall-mounted
Floor 9
H O S P I TA LE L E VAT O RB
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Floor 10
MULTNOMAHELEVATORAUse these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Use this elevator to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
Orthopedics 10
Ultra Sound 10
DESTINATION FLOOR
Use this elevator to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
DESTINATION FLOOR PHYSICIANS LISTINGCafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
Orthopedics 10
Ultra Sound 10
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
Orthopedics 10
Ultra Sound 10
D-3f Custom Elevator Directory
Floor 3
G HATFIELD ELEVATORUse these elevators to access the following destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
DESTINATION FLOOR DESTINATION FLOOR
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hospital Administration 8
Information 9
D-3g Elevator Directory
Floor 1
SCHOOL OF NURSINGELEVATOR
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
DoernbecherChildren’sHospital
Hatf ieldResearch Ctr
KohlerPavilion
Tram
You are in the Hospital Floor 9
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
You are in the Hospital Floor 9
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
DoernbecherChildren’sHospital
Hatf ieldResearch Ctr
KohlerPavilion
Tram
You are in the Hospital Floor 9
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
You are in the Hospital Floor 9
H AT F I E L D R E S E A R C H C E N T E R
D-3eThe physician directory listing is an alphabetical by last name listing of physicians. The directory can be used at a suite entrance, or at a building entrance.
D-3, D-3a, D-3f, D-3gThis wall mounted sign type is located at every public elevator bank and lists the public destinations that are accessible via that elevator, along with the floor where the destination is located. The directory should be located on the same wall as the elevator doors and call buttons. Destinations are separated between public destinations and patient units, and listed alphabetically within each group.
The more decorative version of the D-3 is for use on the ninth floor of the Hospital, Kohler and Hatfield buildings only. The D-3a, D-3f and D-3g are to be used in all other locations.
D-3b, D-3cThese inside cab elevator directories are the same as the D-3a directories, but are located inside of the elevator cab rather than in the elevator lobby. Destination listings and organization should match the elevator directory in the lobbies.
D-4, D-4a, D-4b, D-4cThese wall-mounted sign types indicate the current floor and depicts a simplified version of the floor plan, showing symbols and destinations that are nearby. The user’s location is marked with a “You Are Here” arrow. The map should be correctly oriented to the viewer, so that the top of the map shows the direction that the viewer is facing. The D-4 and D-4b signs also contain a second insert with at-a-glance directional information for nearby buildings and the tram only. This sign type is to be used within long corridors to reinforce one’s location and direction, or at complex decision points.
The more decorative version of the D-4 and D-4a are for use on the ninth floor of the Hospital, Kohler and Hatfield buildings only. The D-4b and D-4c are to be used in all other locations.
D-5This custom overhead is to be used to mark when a visitor transitions from one building to another. When the building transition includes a change in floor, include the new floor information as well.
The following signs are installed 70" from the top of the sign window frame to the floor. This places important wayfinding information at a standard reading level for all visitors.
70"
The following signs are installed 70" from the top of the sign window frame to the floor. This places important wayfinding information at a standard reading level for all visitors.
Installation height and size of this sign varies depending on location. The sign cannot hang over a pathway lower than 80”.
70"
1'-8 3/4"
2'-11"
1'-6"
2'-7 1/2"
1'-6"
2'-8"
2'-7 1/2"
1'-4 1/2"
1'-10"
1'-0"
1'-0"
1'-0"
2'-1"
2'-0"
2'-3 7/8"
3'-0 1/2"
2'-3 7/8"
2'-2 1/2"
2'-0 7/8"
2'-10"
2'-0 7/8"
2'-0"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Directories 7
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
G-1 Guide Sign, Large, Decorative G-1a Guide Sign, Medium, Decorative G-1b Guide Sign, Small, Decorative G-2 Guide Sign, Large G-2a Guide Sign, Medium G-2b Guide Sign, Small
G-3 Guide Sign, Freestanding
Floor 9
EMERGENCY Elevator
Conference Room 9D53Hatfield ElevatorHospital AdministrationMarquam CaféRestroom
G
Floor 9
Stairs toEMERGENCY
To OHSU Hospital
Floor 9
Hospital Administration
Conference Room 9D53Marquam CaféRestroomTo OHSU Hospital
Floor 1
Library ResearchAdministration
To OHSU HospitalTo Parking Garage
Floor 2
Movement DisordersProgramParkinson Center of OR
To Multnomah Pavilion
Floor 5
Division of VascularSurgeryMultnomah ElevatorA
Kohler OutpatientElevatorPatient Rm 9020-9144To Parking Garage
Floor 9
G-1, G-1a, G-1b, G-2, G-2a, G-2bThese sign types are used to direct to elevators and nearby primary and secondary public destinations. Guide signs are located at key decision points or within long corridors where confirmation of direction is needed. The large version of this sign frame has space for up to 11 arrow and destination lines, the medium has space for up to 9 arrow and destination lines, and the small frame can display up to 7 arrows and destination lines. Destinations shall be listed in the following order - left, right, then straight ahead. Destinations within each arrow group are listed alphabetically. If an arrow grouping includes Emergency, then that arrow group is listed first, and Emergency is the first destination.
The more decorative version of the G-1, G-1a, and G-1b are for use on the ninth floor of the Hospital, Kohler and Hatfield buildings only. The G-2, G-2a, and G-2b are to be used in all other locations.
The following signs are installed 70" from the top of the sign window frame to the floor. This places important wayfinding information at a standard reading level for all visitors.
70"
G-3The G-3 sign type can be used on any floor, and is to be used in locations where a visitor needs guide information, but there is no wall space available for a wall-mounted sign.
2'-3 7/8"
1'-8 5/8"
1'-11 3/4"
1'-8 5/8"
1'-7 1/4"
1'-8 5/8"
2'-1"
1'-6"
1'-9"
1'-6"
1'-5"
1'-6"
5'-7 3/8"
1'-6 3/4"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Guides 8
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
O-1e Projecting Identifier, Small,Ceiling Mount
4
O-1a Projecting Identifier, Large,Ceiling Mount
HospitalElevator
O-1f Projecting Identifier, Small,Wall Mount
4
O-1d Projecting Identifier, Medium,Wall Mount
O-1c Projecting Identifier, Medium,Ceiling Mount
O-1g Projecting Identifier,Ceiling Mount
E
O-1h Projecting Identifier,Wall Mount
E
O-1b Projecting Identifier, Large,Wall Mount
Waiting
O-2 Overhead Identifier/Guide, Double-sided, Ceiling MountO-2a Overhead Identifier/Guide, Single-sided, Wall Mount
Casey Eye Elevator
O-2, O-2aOverhead signs used to highlight or direct to primary public destinations perpendicular to the path of travel. These are primarily used to identify public elevators and the top 10% of the public destinations. This sign only displays one line of text.
O-1a-h, O-4aLarge projecting signs are to identify elevators and primary public destinations. Medium projecting signs are used for identifying public amenities and sometimes destinations, provided the minimum cap height can be met. Small projecting signs are used for numbering bays or to identify fire extinguisher locations. Wall-mounted projecting signs are preferred where possible.
KohlerOutpatientElevator
O-4a Projecting Identifier/Guide,Ceiling Mount
O-4b Projecting Identifier/Guide,Wall Mount
80"
27"
80"
27"
the floor for optimal clearance and visibility. For ceiling heights above 10', signs shall be rigidly suspended down to 94" from the bottom of the sign to the floor. Overhead signs may not be installed above 10' without increasing the text height to 3" or greater.
Per ADA regulations, overhead projecting, identification and guide signs cannot be mounted below 80" above the finished floor. Minimum text height for all messaging is 2". For ceiling heights up to 10', signs shall be mounted at 85" from the bottom of the sign to
85"
85"
Down toFloor 1North Café
10"
1'-4 1/2"
8"
9"
6"
6"
10"
1'-4 1/2"
8"
9"
6"
6"
8"
1'-3"
8"
1'-3"
1'-3"
1'-6"
1'-3"
1'-6"
8"
4'-0"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Overheads 9
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
80"
27"
O-3 Overhead Guide, Large, Double-sided, Ceiling Mounted,O-3a Overhead Guide, Large, Single-sided, Wall Mounted
O-6 Overhead Identifier/Guide, Ceiling MountO-5c Overhead Guide, Double-sided, Projection Mounted O-6a Overhead Identifier/Guide, Wall Mount
Elevator to ParkingTo OHSU Hospital
O-5b Overhead Guide, Double-sided,Ceiling Mount
Diagnostic Imaging Rheumatology andImmunology InfusionOrthopaedics and Rehab
O-5 Overhead Guide, Double-sided,Ceiling Mounted
O-3, O-3a, O-5, O-5b, O-5c, O-6, O-6aThese overhead signs are used to direct to high-level destinations at key decision-making points where adequate sight lines are available and a wall guide at standard height cannot be used to provide the direction. Their use should be minimized as people, particularly the elderly, tend to avoid looking up for directions. The O-3 sign face can display upto two destinations, whereas the O-5 and O-5b signs can hold upto four destinations per sign face. Destinations should be listed left, then right, then straight-ahead. If both destinations are in the same direction, they should be listed alphabetically.
85"
80"
27"
85"
NOTE: The Mounting Guidelines included on these pages are provided as a reference only. The guidelines are an interpretation of the 2010 ADA Standards for Accessible Design, and are not to be construed as legal advice concerning compliance with any law or regulation.
the floor for optimal clearance and visibility. For ceiling heights above 10', signs shall be rigidly suspended down to 94" from the bottom of the sign to the floor. Overhead signs may not be installed above 10' without increasing the text height to 3" or greater.
Per ADA regulations, overhead projecting, identification and guide signs cannot be mounted below 80" above the finished floor. Minimum text height for all messaging is 2". For ceiling heights up to 10', signs shall be mounted at 85" from the bottom of the sign to
ReceptionWaiting
Check-in Building 2Ctr for Health & Healing - Bldg 1Pharmacy Building 2Tram
Day Stay Surgery Admit/Waiting
Short Stay UnitTo Sam Jackson Hall
Multnomah ElevatorA
10"
4'-0"
1'-7"
4'-6"
10"
6'-0"
8"
3'-0"
8"
3'-0"1'-8"
4'-6"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Overheads 10
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
4"
60"
48"
I-1d Classroom/Lab Identifierw/Insert
I-1e Primary Identifierw/Letter-sized Insert Holder
Classroom8N124
8 N124SJFGHZSJHGJHG
MarquamCafe
MARQUAM C AFEMARQUAM CAFE
I-1d and I-1eThe I-1d includes a half-letter sized insert holder within the sign frame to allow for added messaging, such as classroom notices, hours of operations, or other special instructions. The I-1e includes a letter-sized insert holder and is similarly used for additional information that is pertinent to the patient or visitor.
I-1 Primary Identifier, Decorative I-1a Primary Identifier,w/Slider, Decorative
I-1b Primary Identifier I-1ca Primary Identifierw/Slider
I-1c Classroom/Lab Identifierw/Notifier Bar
PhysicalTherapyTerapia física
PHYSIC AL THER APYHEALTH CONNECTIONS
ConferenceRoom 9D53
CONFERENCE ROOM 9D53HEALTH CONNECTIONS
In Use
Pharmacy
PHARMAC YHEALTH CONNE
ResearchAdministration
RESEARCH ADMINISTR ATIONHEALTH CONNECTIONS
Classroom8N124
8 N124
I-1, I-1a, I-1b, I-1ca, I-1c, I-1d, I-1eThis wall-mounted sign type displays the name of a primary public destination and repeats the name in tactile and Braille lettering. Only the top 10-15% of destinations will receive this high-level sign type. This sign is to be placed at the entrance to the destination and mounted in accordance with ADA requirements. International symbols from the graphic standards page are used where appropriate.
The decorative I-1 and I-1a sign types are to be used on floor 9 of the Hospital, Kohler and Hatfield buildings only. The remaining options are for use everywhere else.
Note that tactile signs must be installed such that a clear floor space of 18 inches by 18 inches, centered on the tactile copy, is provided outside of the swing of a door. (Illustration 3A and 3B)
ADA states that tactile room identification signs shall be installed on the latch side of the door (Illustration 1A). In the case of a double door, the sign shall be installed on the inactive leaf of the door (Illustration 1B). If both doors are active, then the sign is installed to the right of the right hand door (Illustration 1C). If there is no space on the latch side of the door, or to the right side of the double doors, then the sign is to be installed on the nearest adjacent wall space.
ILLUSTRATION 1A ILLUSTRATION 1B ILLUSTRATION 1C ILLUSTRATION 2 ILLUSTRATION 3A
Signs with tactile characters may be installed on the push side of a door (doors that open into the room, not into the circulation space), so long as the door has a closer and is not on a hold-open device. For example, restroom doors that push open into the restroom, and the door automatically closes, may have the tactile identification sign installed on the door. This is not preferred if space is available on the latch side of the door. (Illustration 2)
Inactive door Self-closing doorthat pushes open
Sign Center line
ILLUSTRATION 3B
Sign
Centerline
18"x18"clear floor and wall space
18"x18"clear floor and wall space
NOTE: The Mounting Guidelines included on these pages are provided as a reference only. The guidelines are an interpretation of the 2010 ADA Standards for Accessible Design, and are not to be construed as legal advice concerning compliance with any law or regulation.
ConferenceRoom
CONFERENCE ROOMCONFERENCE ROOM
In Use1'-2 3/8"
1'-4 3/4"
1'-2 3/8"
1'-4 3/4"
11 3/8"
1'-2"
11 3/8"
1'-2"
1'-0 3/4"
1'-2"
1'-4"
1'-2"
1'-8 3/8"
1'-2"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Identifiers 11
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
60"
48"
I-4, I-4a Patient Room Identifier I-5 Utility Identifier I-6 Cubical Identifier I-9 Research Bay Identifier
3453 4 52478
Leah CuddingtonAssistant
FACILITIES SVCS WORKSHOP
4 N 0 81BT I S S U E C U LT U R E
I-4, I-4aThis wall-mounted sign type displays the number of the patient or exam room on the insert and the architectural room number in tactile and braille characters. The I-4a sign includes a notifier bar for patient caution information.
I-5This small wall-mounted identification sign is used to designate the architectural room number and room function for utility type rooms such as telecommunication, electrical, housekeeping, etc.
I-6Nameplate signs identify staff office spaces where tactile and braille are not required by code. The copy on this sign is limited to the occupants name and title only.
I-9This small label is for use in academic and research lab settings to identify lab desk assignments.
I-2 Secondary Identifier I-2a Conference Room Identifierwith insert Holder
I-3, I-3a General Room Identifier
Patient andFamily Lounge
247 8GJHG
Kenneth C. SwanLibrary
247 8GJHG
Hours:Monday-Thursday8:00am-4:00pm
Reserved for faculty and staff.
6 7 8GJHDFG
Office
I-2 and I-2aThese slightly smaller wall mounted identification signs are to be used at more secondary public destinations. The I-2a sign is only for use at conference rooms, where the lower insert holder can be used to post the room reservation schedule.
I-3, I-3aThis smaller room identification sign is to be used at exam rooms, offices and non-public or back-of-house destinations. The tactile/braille panel should be used to display the room number. The I-3a sign includes a notifier bar for temporary postings.
9" from center ofsign to edge of door
I-7 Individual Letters I-8 Logo
I-7 and I-7cThe I-7 is for use at information and/or admitting desks only. The I-7c is for use at check-in desks or waiting rooms.
I-8Use of this sign type must be approved by the Chief Marketing Officer.
Installation height and size of these signs vary depending on location.
3 N 0 6 8 . A1
NOTE: The Mounting Guidelines included on these pages are provided as a reference only. The guidelines are an interpretation of the 2010 ADA Standards for Accessible Design, and are not to be construed as legal advice concerning compliance with any law or regulation.
8 3/4"
8 1/2"1'-8 1/2"
8 1/2"
7"
8" 8"
7"4"
8"
3 1/2"
9"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Identifiers 12
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
V-3 Vinyl on Elevator Door V-4 Vinyl on Staff Elevator Door V-5 Door Vinyl
Access to Floors 2-16B U I L D I N G 1
Staff Only
P 216 0
TBD TBD
11"
2'-6"
6 3/4"
3"(w.) x 1"(h.)
Drawing Revised 6/12/19 Manual Revised 6/12/19
Identifiers 13
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
60"
N-1a Notice Holder N-1b Notice Holder N-1c Notice Holder N-1d Notice Holder N-1e Notice Holder N-1f Notice Holder N-1g Notice Holder
N-2 General Information N-2a General Information N-3 General Information
Please lockthe door.
Please lockthe door.
Accessible Path to Hospital
Take Elevator toLobby to access
DoernbecherChildren’s Hospital.
Cell phones may interfere with patient care equipment.
No cell phones in this area.
N-2, N2a, N-3These simple flat acrylic sign types are used to convey information such as restricted access or special instructions.
N-1a-gThese simple wall-mounted, desktop and freestanding signs are used to display general information notices in various sizes and orientations. If a sign requires easy removal of the insert, the sign frame can be ordered with a thumb slot.
NOTE:An N-1g sign with the message “Please wait here” is required for all check-in desk locations.
60"
Although no mounting height is specified by ADA guidelines for a sign without tactile and braille it’s recommended this sign be mounted 60" to center from the floor so that its height is consistent with other signs. NOTE: Any text above 70" from the floor must be a minimum of 2" in height.
WOMEN2478
RADIATION AREA BIOHAZARD
6"
8"
11"
8 1/2"
1'-5"
11"
8 1/2"
11"
8 1/2"
11"
8 1/2"
11"
1'-5"
11"
3'-8 3/4"
8"
8"
1'-0"
1'-0"8"
~4 1/2"
Drawing Revised 6/12/19
All are welcome to use the restroom that aligns with
their gender identity or expression.
Manual Revised 6/12/19
Notifiers 14
STANDARDS MANUAL FOR WAYFINDING SIGNAGE
60"
48"
9" from center ofsign to edge of door
R-1 Regulatory
WOMEN2478
EXIT STAIRS2478FDVBSDF
R-3 RegulatoryR-1a Regulatory
WOMEN2478
Changing TableAvailable
R-2 Regulatory Stairwell
R-1, R-1a, R-2 and R-3This collection of sign types are used to comply with code requirements for the identification of restrooms, stairs, or interior stairwell instructions. Fire codes, building codes, ADA, and other regulations dictate the placement and use of these signs.
See the Restroom Sign Standards page for additional details regarding restroom signage required by OHSU.
STAIR 1ROOF ACCESS
91 THROUGH ROOFEXIT THIS LEVEL
LEVEL V1
★ F L O O R 1
NOTE: The Mounting Guidelines included on these pages are provided as a reference only. The guidelines are an interpretation of the 2010 ADA Standards for Accessible Design, and are not to be construed as legal advice concerning compliance with any law or regulation.
9"
8"
10 7/8"
8"
1'-6"
1'-0"
2 1/4"
8"
Drawing Revised 6/12/19 Manual Revised 6/12/19
Regulatory 15
SILVER:MP18099 PLATINUM SPARKLE METALLIC VINYL: 3M SATIN ALUMINUM
CHAMPAGNE:MP20051 SANDALWOODMETALLIC
DARK BLUE:PANTONE 533
LIGHT BLUE:PANTONE 534
BEIGE:PANTONE 7527
WHITEVINYL: 3M WHITE 7725-10VINYL: 3M MATTE WHITE 7725-20
RADIATION YELLOW:PANTONE 394
BIOHAZARD ORANGE:PANTONE 1665
CLEAR MATTE ACRYLIC
RADIATION PINK:PANTONE RUBINE RED
MYRIAD PRO FAMILY:
Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm NnOo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz1234567890
MYRIAD PRO CONDENSED
MYRIAD PRO SEMIBOLD CONDENSED
Aa Bb Cc Dd Ee Ff Gg Hh Ii Jj Kk Ll Mm NnOo Pp Qq Rr Ss Tt Uu Vv Ww Xx Yy Zz1234567890RED:
PANTONE 1797
PARKING & BARRIER FREE BLUE:PANTONE MEDIUM BLUE
ALUMINUM MESH SCREEN
3M DUSTED CRYSTAL ACRYLIC
Typesetting Example: Apostrophe
Visitor’s - correctVisitor's - incorrect
Typesetting Example: Ligatures
Staff - correctStaff - incorrect
BLACK
Fabricator is responsible for matching all colors and materials as specified and is required to provide color and material samples for approval. CONSISTENT AND ACCURATE COLOR REPRODUCTION IN THIS DOCUMENT CANNOT BE ASSURED DUE TO THE LIMITATIONS OF COLOR PRINTING TECHNOLOGY.
The Coated Pantone Matching System® and Matthews Paint system are used for specifying signage color matches. (In the absence of
actual sign material color chip reference sets, actual specified product color swatches should be referenced for color matching.)
Shown here are approximations of the signage background colors and supporting accent colors. Actual color finishes on signage are to be matte or low luster (not shiny or glossy) and exclusively a premium acrylic polyurethane.
The font used for this project was selected specifically for this project by the Designer and Owner.
It is the responsibility of the fabricator to purchase the fonts. Purchasing information can be obtained at the following websites:http://www.adobe.com/
No substitution of any other typefaces may be made. Under no circumstanc-es are typefaces to be electronically distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composition unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.
NOTE:Selected fabricator will need to match insert ink with APCO Cool Gray 11 ink swatch for consistent match.
DARK GREY:PANTONE COOL GRAY 11
NOTE: The colors for OHSU and RLSB symbols and sign backgrounds are different. Above are examples of how color is applied to symbols depending on the building of installation. Color should be applied to all signs within a building consistently.
OHSU symbol RLSB symbol
Specifications Revised 6/12/19
16
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Color and Typography
All arrows, symbols or graphics shall be produced either by photographic or computer-generated means. Hand-cut characters are not acceptable.
No substitution or creation of any new symbols may be made without prior approval. Under no circumstances are symbols to be electronically distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composition unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.
B
Drawing Revised 6/12/19
INFORMATION
ELEVATOR
FOOD AND BEVERAGE
STAIRS
VENDING
PHONE
ELEVATOR LETTER
ATM
LABOR & DELIVERY
SURGERY
OPTHAMOLOGY
BILLING
REGISTRATION
INTERNAL MEDICINE
RADIOLOGY
MEDICAL RECORDS
CHAPEL
INTERPRETIVE SERVICES
CARDIOLOGY
LABORATORY
AMBULANCE
PHARMACY
FAMILY PRACTICE
OUTPATIENT
INTENSIVE CARE
WAITING
PHYSICAL THERAPY
CAFE
LACTATION ROOM
ARROW
GIFT SHOP
UNISEX RESTROOM
BARRIER-FREEUNISEX
RESTROOM
BARRIER-FREEUNISEX
RESTROOMR-1/1a Signs Only
UNISEXRESTROOM
R-1/1a Signs Only
MEN’SRESTROOM
BARRIER-FREEMEN’S
RESTROOM
BARRIER-FREEMEN’S
RESTROOMR-1/1a Signs Only
MEN’SRESTROOM
R-1/1a Signs Only
WOMEN’SRESTROOM
BARRIER-FREEWOMEN’SRESTROOM
BARRIER-FREEWOMEN’SRESTROOM
R-1/1a Signs Only
WOMEN’SRESTROOM
R-1/1a Signs Only
PATIENT RELATIONS
17
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Symbols
All arrows, symbols or graphics shall be produced either by photographic or computer-generated means. Hand-cut characters are not acceptable.
No substitution or creation of any new symbols may be made without prior approval. Under no circumstances are symbols to be electronically distorted (“squeezed” or “extended”) for purposes of fitting to the specified sign or general alteration of the sign face composition unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.
Drawing Revised 6/12/19
NO SMOKING
PARKING DO NOT ENTER
BIOHAZARD
RADIATION DOLLY
TRAM
NO CELL PHONES
NO FLOWERS
NO FRAGRANCES
FIREEXTINGUISHER
ENTRY
BARRIER-FREE
18
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Symbols
SECTION 10 14 01 – INTERIOR SIGNAGE
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes specifi cations related to fabrication and installation of interior project signage.
1. Sign type details are listed in the Design Intent Drawings. Design drawings are provided to the Fabricator in PDF format, or in the current version of Adobe Illustrator.
2. Sign Location Plans are general in nature and not to scale. They refl ect locations deemed desirable for the effectiveness of the overall wayfi nding plan. Sign location plans are provided to the Fabricator in PDF format.
3. The Sign Message Schedule includes sign type, exact messaging, layout details, and provides additional installation or graphic layout information specifi c to each sign location. Sign message schedules are prepared in FileMaker. Fabricator will be provided information in PDF format sorted by sign type and by sign number. Data is also available exported into an Excel fi le upon request. A link to the FileMaker database can also be supplied.
4. The materials, products, equipment and performance specifi cations within these documents describe the standard of required function, dimension, appearance, performance and quality to be met by the Fabricator.
B. Fabricator’s responsibilities:
1. Engineer, fabricate and install all signage and graphics per the fi nal documents provided at contract award.
2. Be knowledgeable of relevant federal, state and local code requirements, and be responsible for ensuring that all signs meet current local, state and federal codes, especially, but not limited to, ADA and Fire/Life Safety codes.
3. Perform complete structural design and engineering of the signs and to incorporate all the safety features necessary to adequately support the sign for its intended use and purpose, as required for approvals and permits, and to protect the Owner. All signs shall meet local, state and federal codes. Engineered shop drawings for suspended project signage and signage weighing more than 20 lbs shall be reviewed, stamped and signed by a registered engineer. Shop drawings are to be provided for all sign elements.
4. Signs listed in the sign message schedule should match those on the sign location plan. Fabricator to notify the Designer and Owner’s Representative of any discrepancies before manufacturing the signage
5. Generate graphic layouts for all sign messages, including necessary tactile and Grade 2 Braille (conforming to the 2010 ADA Standards for Accessible Design) from the sign message schedule meeting the Design Intent Drawing specifi cations.
6. Visit the site to observe existing conditions, verify mounting conditions and space availability, take fi eld measurements and verify all signage locations with Owner’s Representative prior to starting fabrication.
7. Notify the Owner’s Representative immediately if any discrepancies exist within the Construction Documents or fi eld conditions.
8. Provide all submittals outlined in the specifi cations in a timely fashion and according to the agreed upon contract schedule.
9. Work with the Owner’s Representative to coordinate with other trades performing work on site.
10. Maintain all project related fi les such that the Owner may reorder additional signs for a minimum of 10 years after the completion of the work.
1.2 WARRANTY
A. Extend in writing all manufacturers’ warranties.
B. Obtain a minimum fi ve (5) year extended warranty on all paint and powder coat applications.
C. Obtain a minimum eight (8) year warranty on all custom color vinyl or fl ood-coated vinyl applications. Vinyl shall not fade excessively, discolor, crack, peel, or blister.
D. Obtain a minimum fi ve (5) year warranty on all applied vinyl applications. Vinyl shall not fade, discolor, delaminate, crack or curl.
E. Provide a written full replacement warranty for fi ve (5) years starting from the completion of installation that all signs will be free of defects due to craft work and materials including, but not limited to:
1. Bubbling, chalking, rusting or other disintegration of the sign panel, graphics or of the edges.
2. Corrosion appearing beneath paint surfaces of panels, brackets, posts or other support assemblies (except as an obvious result of vandalism or other external damage).
3. Corrosion of fasteners.
4. The assemblies not remaining true and plumb on their supports.
5. Fading, chalking and discoloration of the colors and fi nishes within the vinyl and paint manufacturer’s stated warranty period.
6. Peeling, delamination or warping (“oil canning”).
7. Repair and reinstallation of signage due to failed mountings.
F. Repair or replace, including installation, any defective signs or hardware, which develop during the warranty period and repair any damage to other work due to such imperfections at no charge to the Owner and to the Owner’s satisfaction.
G. The Fabricator will be required to fully replace all signs that are in error relative to the working documents (sign message schedule and sign type drawings) that were submitted to the Fabricator upon award of contract.
H. Correct any installation misalignments at no charge.
1.3 DESIGN RIGHTS
A. The Fabricator is hereby granted limited right to the designs as shown and specifi ed herein for the sole purpose of completing contractual obligations to fabricate and install project signage. Fabricator may not manufacture, reproduce or exhibit these designs, or modify them for any other purpose without prior written consent from both the Owner/Owner’s Representative and the Designer.
1.4 SUBMITTALS
A. Pre-Fabrication Submittals: Submit the following to the Owner’s Representatives and Designer for review and approval prior to commencing with signage fabrication.
1. Shop Drawings: Detailed engineered shop drawings for each sign type are to be submitted as electronic PDF no larger than 11"x 17". Final Shop Drawings are to be stamped by a licensed engineer to ensure structural integrity and safety. The shop drawings for each sign type shall illustrate/describe the following:
a. Elevations and cross sections – front, sides, top and back; side sections; internal structure section/details; enlarged details such as of extrusions, push-through letter mounting, mounting plate; and access panel, etc.; with all fi nal dimensions and call-outs for:
1) Components – construction details/information related to individual elements
2) Materials – color, type, gauge, and thickness (including substrates and overlays)
3) Finishes – color, type of product, manufacturer, and sheen
4) Fonts, graphics specifi cations and message fi elds
b. Exploded view, unless otherwise indicated – isometric view with components, materials, and fi nishes.
c. Cross-section of corners – one illustration for each corner condition. Items to be illustrated: seams, joints, layers, internal support and fasteners.
d. Mounting/installation details – provide foundation cross-sections (including hardware), bracket/post details, elevations, materials, fi nishes and fasteners.
e. Removable panels (where applicable)
f. Identify any dimensional or other changes in the overall sign required by virtue of the fabrication materials, techniques and/or engineering.
2. Samples: Submit three (3) samples of each material listed in the design intent material specifi cations using actual substrate materials for review and approval. One will be returned, one kept by the Owner’s Representative and one kept in the Designer’s records.
a. All material samples to be 3"x3".
b. Insert artwork samples to be 12" x 12", and are to be at 100% scaled segments of the fi nal insert artwork for interior guide signs, directories and maps
c. Label the back of every sample with the project name, sample designation and fabricator name.
d. The Owner’s Representative and Designer reserve the right to reject any sample and require additional samples as necessary to obtain fi nal approval.
3. Keystroke Proofs: Provide a proofi ng document of fi nal production keystroke output for all sign messages to verify line breaks, character and word spacing, and interline spacing.
a. The proofs are to be scaled production art fi les, not full sized.
b. Layouts are to be organized by sign type and by sign number within each sign type group.
c. Each layout is to be identifi ed with the corresponding sign number.
4. Schedule: Provide a detailed fabrication and installation schedule.
a. Include all pertinent dates and milestones such as submittal delivery dates, required approval dates, fabrication dates and installation dates.
b. Include all lead times for materials and third-party supplied items.
c. Allow a minimum of 15 business days for Owner Representative and Designer review with one round of revisions built in unless otherwise noted within the bid schedule.
d. Include submittal delivery dates.
B. During Fabrication Submittals:
1. Fabricator is required to maintain the detailed fabrication and installation schedule, submitting weekly updates as changes occur.
19
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Fabrication Specifications
2. Upon request, Fabricator is to submit photo documentation of signage at various stages of fabrication and installation. Review of these photos does not rule out rejection of the sign during the punch list if they do not meet fabrication requirements.
C. Post-Fabrication Submittals: Upon completion of the initial installation, the following are to be submitted to the Owner’s Representatives.
1. Maintenance instructions and manuals for all sign components (paint, etc.), along with fi nal amended shop drawings, as-installed sign location plans and approved keystroke documents.
2. Templates for all insert based signs, utilizing standard software for the Owner’s use in printing replacement inserts.
3. One (1) pint of each fi nish paint color for touch-up purposes.
4. Labeled, spare keys to master keyed locks on directory or kiosk signage.
5. Warranty documentation, as outlined above.
1.5 QUALITY ASSURANCE
A. The materials, products, equipment and performance specifi cations described within, establish a high quality standard of required function, dimension, appearance, performance and quality to be met by the Fabricator.
B. Materials used for this project shall be new materials, not reconditioned.
C. Fabricator shall only use workforce skilled and experienced with the products, fabrication methods, and installation requirements outlined for this project.
D. Fabrication and installation is to withstand severe abuse and souvenir theft vandalism, but not less than the equivalent of resisting simple hand implements and tools (screwdrivers, knives, coins, keys, and similar items), and adult physical force. It is the fabricator’s responsibility to suggest alternate fabrication or installation methods, should they be deemed necessary to hinder theft or vandalism.
E. Regulatory Requirements: Signage shall meet or exceed requirements of all current applicable local, state and federal codes, including, but not limited to:
1. 2010 Americans with Disabilities Act Standards for Accessible Design, including local modifi cations and amendments; and
2. Local and State Building and Fire Codes.
1.6 DELIVERIES, STORAGE AND MATERIAL HANDLING
A. Pack, wrap, crate, bundle, box, bag, or otherwise package, handle, transport, and store all fabricated work as necessary to provide protection from damage by every cause.
B. Provide clear and legible identifying information on all product packaging to ensure proper on-site identifi cation and installation.
C. Coordinate the delivery and secure storage of signs with the Owner’s Representative to meet deadlines.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Substitution:
1. No substitution will be considered unless the Owner’s Representative and Designer have received written request for approval.
2. Equal or better equipment or method may be recommended, but will be required to provide full documentation establishing such a substitution’s equality or superiority as measured in: compliance with the visual design intent, cost, ease of maintenance, and performance.
3. The Owner’s Representative and Designer’s decision of approval or disapproval of a proposed substitution shall be fi nal.
B. Approved manufacturers include:
1. Acrylic Polyurethane Paint: Matthews Paint Company or Akzo Nobel
2. Interior Vinyl: 3M or Oracal
3. Non-glare front lens: Calsak Acrycast LX or equal
4. Acrylic Sheets: Rohm and Hass Co, Acrylite or equal.
5. Interior Extrusions: SignComp, Charleston Industries or equivalent
6. Adhesive Silicone: Dow Corning or equivalent
7. Adhesive Tape: Polyfoam or “Isotac” by 3M or equivalent
2.2 Materials
A. Aluminum: suitable for ornamental work. Finish to be smooth and free of imperfections. Alloy based upon structural requirements of the signage design.
B. Aluminum sheet: .125" minimum thickness unless otherwise specifi ed.
C. Aluminum plate: .25" minimum thickness unless otherwise specifi ed.
D. Structural Steel: galvanized rolled steel or equal as required to meet structural requirements.
E. Acrylic sheet: varying colors and thicknesses as noted on design intent drawings.
F. Adhesive vinyl: solid color, refl ective color, and transparent color.
G. Interior grade paint: acrylic polyurethane paint in solid and metallic colors with primer and satin clearcoat fi nish, unless otherwise noted.
H. Miscellaneous mounting hardware: including but not limited to, screws, bolts, steel cable, hinges, and adhesives.
I. Fonts: purchase fonts associated with the project. See typography standards within the design package.
J. Labels: Only labels required by law are permitted on the exterior of the sign face.
1. Labels shall not be on the primary messaging faces of the sign, unless dictated so by the local ordinance.
2. Labels shall be located in a position as discreet as possible.
3. No other labels are permitted on the signs.
4. Fabricator contact information may be placed inside the sign on the access panel.
K. All printed graphics shall be printed at a minimum of 1200 DPI using interior grade UV inks.
2.3 FABRICATION
A. Details on design drawings indicate a design approach for sign structure but do not necessarily include all fabrication details required for the complete structural integrity of the signs, including consideration for static, dynamic and erection loads during handling, erecting, and service at the installed locations.
B. Site-verify all locations to determine special installation requirements. Field verify measurements for ceiling suspended, wall mounted and glass mounted signage, etc. prior to fabrication.
C. Fabricate signage such that major components of the sign can be removed and replaced with similar components. Incorporate this changeability such that it does not promote vandalism, but can be done by a qualifi ed maintenance crew.
D. Within fabrication tolerances, allow for expansion and contraction of materials due to temperature changes as appropriate to the project location.
E. Construction Methodology:
1. The drawings call for a variety of fabrication techniques.
2. Sign faces requiring aluminum plate of varying thicknesses, as specifi ed on design drawings, with a minimum thickness of .125 inches unless otherwise noted.
3. Conceal all fasteners except for access panels or where approved otherwise by Owner’s Representative and Designer. Access panel fasteners are to be stainless steel, tamper resistant, counter-sunk fl ush screws, painted to match adjacent fi nish.
4. All hardware and fasteners within reach shall be vandal resistant.
5. To prevent electrolysis, separate all ferrous and non-ferrous materials with a non-conductive gasket or barrier and utilize stainless steel fasteners as required.
6. Welded joints:
a. Exposed welded joints must be fi lled and ground smooth so that there is no seam visible when painted.
b. Dimensional and structural welding defects will not be accepted, including but not limited to: poor weld contours, including excessive bead convexity and reinforcement, and considerable concavity or undersized welds; cracks; undercutting; porosity; incomplete fusion; inadequate penetration; spatter; and non-metallic inclusions.
c. Welding is to be performed by AWS (or similar) certifi ed personnel, following AWS Standard Welding Procedure Specifi cations (SWPSs) for steel, aluminum, and stainless steel as appropriate.
7. Non-welded joints between various portions of signs must have a tight, hairline-type appearance, without gaps. Provide suffi cient fastenings to preclude looseness, racking, or similar movement.
8. Exposed acrylic edges are to be fi nished such that no saw marks are visible.
9. Visible metal joints must adhere to a fi t tolerance of .01".
10. Sign panels shall be appropriately pre-drilled/pre-cut before priming and painting or coating.
F. Painting:
1. Metal surfaces are to be painted per the most recent Matthews Paint or Akzo Nobel product bulletins.
2. Paint preparation of all metal surfaces of the sign to include removal of all scratches and imperfections, sanding and chemical etching.
3. Substrate cleaning, preparation, paint application and paint thickness to be in strict compliance with Matthews Paint or Akzo Nobel published recommendations.
4. Aluminum and Steel surfaces to be properly covered with a primer.
5. Acceleration of the drying process is not allowed.
20
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Fabrication Specifications
6. All paint fi nishes to be a satin fi nish unless otherwise noted in the design drawings.
7. All painted surfaces to have a clearcoat fi nish to add UV protection and protection from cleaning chemicals.
G. Fonts/Typefaces:
1. Fonts used within the Designer’s programs were purchased by and are licensed to the Designer. It is the responsibility of the fabricator to purchase the specifi ed licensed fonts for use within this program. See the design intent typography page for the specifi c fonts.
2. The fabricator is responsible for spacing the letters (Kerning) to meet ADA code requirements.
3. Letter height/cap height is based upon the height of the capital letter “E” or any capital character that has a fl at top and base.
4. Under no circumstances are typefaces to be electronically distorted (“squeezed” or “extended”) for purposes of fi tting to the specifi ed sign or general alteration of the sign face composition unless noted in the drawings. This includes (but is not limited to) stretching, squeezing, tilting, outlining or shadowing.
5. Ligatures are to be turned off.
6. Apostrophes and quotation marks are to be used, not footmarks and inches. Note that there is a difference in most fonts.
7. Fabricator to reference spacing within the Design Intent Drawing package. Layout of copy is critical for the proper function of the wayfi nding signage. Any typesetting concerns or issues are to be brought to the Designer for resolution recommendations.
8. Fabricator is responsible for correcting any typesetting errors that may be necessary.
9. All tactile and grade 2 Braille characters are to be created using the photopolymer or raster dot methods as dictated by code requirements.
H. Silk-screen, digital printing and vinyl copy:
1. All letterforms, symbols or graphics shall be reproduced either by photographic or computer-generated means.
2. Cutting shall be done such that edges and corners of fi nished letterforms will be straight, sharp and true.
3. Letterforms with nicked, cut, ragged, rounded corners, and similar disfi gurements will not be acceptable.
4. Copy is to match the sheen of the copy panel background (satin).
5. Surface of letters shall be uniform in color fi nish, and free from pinholes and other imperfections.
6. Silk-screened images shall be executed with photo-processed screens prepared from original electronic art.
7. Use only weather- resistant coating materials that are compatible with substrates.
8. Silk-screening shall be highest quality, with sharp lines and no sawtooths or uneven ink coverage.
9. Images shall be uniform in color and ink thickness.
10. Images shall be free from squeegee marks and lines resulting from improper print stroke or screen off contact height.
PART 3 - EXECUTION
3.1 DEMOLITION
A. It is required that the fabricator remove existing signs as identifi ed in the bidding documents.
B. Fabricator is responsible for repairing and repainting all surfaces damaged through the removal of the existing signage. Owner’s Representative will provide material specifi cations for matching existing surfaces.
C. If there are electrical connections, they must be properly terminated.
D. Fabricator is responsible for disposal of existing signage. Recycling is recommended. Open dumping is prohibited. Coordinate with the Owner’s Representative.
3.2 INSTALLATION
A. Review all sign locations with the Owner’s Representative and ensure that every location has the necessary blocking for safe and secure mounting. Where additional blocking is needed, recommend changes and additional associated costs, and receive approval prior to beginning installation.
B. The fi nal Sign Message Schedule and Sign Location Plan shall be consulted together and shall be approved by the Owner to determine the precise location for each sign. Any necessary adjustments will be made with the approval of the Owner.
C. If installation subcontractors are utilized, the Fabricator must provide a company representative to act as on-site supervisor through the duration of the installation process to oversee any subcontracted installation work.
D. Fabricator to maintain current signage and directional information during installation in order to continue to provide proper wayfi nding. This can be done through the use of temporary signs or temporary mounting of existing signs while walls are repaired.
E. Fabricator to coordinate delivery of signage with the Owner’s Representative.
F. Fabricator to provide a site logistics plan indicating the work areas, proposed equipment and power sources, and schedule time/dates of the respective sign installations. This schedule
is to be updated on a weekly basis if changes occur.
G. Mounting:
1. All signs to be mounted level and true, and within the guidelines of applicable local, state and federal codes including, but not limited to, the 2010 Standards for Accessible Design (ADA) and fi re/life safety codes, where applicable.
2. For all bolts, nuts, washers and other fasteners, Fabricator to use same basic metal or alloy as the metal being fastened and fi nished to match. When fastening dissimilar materials, use stainless steel 300 series.
3. Fabricator is required to specify mounting hardware and anchoring per the engineering of the signage. The visual appearance of the sign is not to be compromised from that shown in the design drawings.
4. Install all signage products such that there are no misalignments between visible components. Sign elements intended to be removable or changeable after installation must function as intended without binding, sticking or blocking.
5. OHSU will not allow substitutions pertaining to VHB tape. OHSU has specifi cally requested that when VHB tape is used, the fabricator will be required to use 3M VHB Grey tape based on its performance and past experiences with this product.
H. Locating Signs:
1. Fabricator’s installers must have applicable understanding of the 2010 Standards for Accessible Design (ADA) mounting guidelines, city zoning and other applicable federal, state and local codes, general sign locating practices, and any particular unique installations.
2. Installers are to follow the regulations, noted guidelines, comments within the Sign Message Schedule and architectural details around an installation location for the best visual placement.
3. Keep a reasonable distance from protruding objects.
4. Any signage that is improperly located is to be moved to the proper location, and all repairs to wall surfaces and signage are to be handled by the Fabricator.
5. If the installers are unable to make a decision about any sign locations, they can contact the Designer, providing a graphic representation of the questionable area, or contact the Owner’s Representative for on-site options. If there is a code requirement regarding the sign location, the installer must notify the Owner’s Representative of the requirement.
I. Upon completion of installation prior to fi nal punch list, Fabricator is to remove any protective covering, tape, or installation hardware. Fabricator is then to clean the sign per the manufacturer recommendations, ensuring that sign is clean from dirt, stains, fi ngerprints, tape residue, etc.
J. All exposed hardware is to be touch-up painted on site as required immediately following installation prior to punch list.
K. All minor blemishes or marring are to be repaired such that the repairs are imperceptible. Components having permanent, non-removable scratches or defects are to be replaced completely.
L. Site Safety and Restoration:
1. Fabricators are responsible for their own safety during the installation period.
2. Maintain a safe environment for pedestrians during the installation period, following OSHA safety standards as necessary.
3. Keep the Owner’s premises and the adjoining premises, driveways and streets clean and clear.
4. Job site shall be left safe, neat and clean at the completion of each day’s operation.
5. In addition to maintaining old or temporary signs for their directional or informational purposes, Fabricator is to maintain signage that meets or exceeds local standards during the installation period.
6. At the completion of work, remove all rubbish, tools, equipment, tape and surplus materials, from and about the premises, and leave the site as originally found.
7. Repair or correct damage to other contractors’ work resulting from signage installation work.
3.2 PUNCH LIST
A. The Fabricator’s onsite representative is to complete a walk through with the Owner’s Representative immediately following installation to identify any errors, such as construction or installation issues. Such errors are to be corrected in a timely manner, and to the satisfaction of the Owner’s Representative.
B. Fully replace all signs that are in error relative to the working documents (fi nal sign message schedule and design drawings).
C. Correct any installation misalignments at no charge.
D. If the Fabricator agrees to a timeline for the Designer’s punch list trip, and then does not complete their scope of work in time for the site visit, requiring the trip to be delayed, the Fabricator will be responsible for associated charges in rescheduling.
END OF SECTION
21
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Fabrication Specifications
DIRECTORIES
22
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S
H O S P I TA L • M A R Q U A M H I L L C A M P U S
D I R E C T O R Y
D I R E C T O R YD I R E C T O R Y
H O S P I T A L • M A R Q U A M H I L L C A M P U S
2'-3"
2"
3 1/2"
1/4"
5'-2"
~6"
5"2 1/2"
1/2"1/2"
9"
2 1/2"
1 3/4"
2 1/2"
1/4"
1/4"
1/2"
7'-2"
9"
6 5/8"1'-3 1/8"
LEFT SIDE VIEW RIGHT SIDE VIEW
TOP VIEW
Custom fabricated, double-sided cabinet with painted custom radius aluminum support poles.
DECORATIVE HEADERCustom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted 1/8” off cabinet. 1/8” spacer should not be visible.
OPPOSITE FACE
DECORATIVE FOOTERCustom fabricated cabinet with painted acrylic panels. Panels should align with insert windows above.
ACCENT BARS3/4” (th.) painted aluminum accent bars welded to support poles. HANDHELD MAP HOLDER
Custom fabricated cabinet with angled slots to hold folded vertical
8.5” x 11” brochure inserts. Fabricator to engineer insert slots and quantity.
Background of cabinet is a painted mesh screen.
BASEPLATESMin. 3/4” (th.) aluminum base (to match accent bars)with chemset studs stainless steel studs and hardware.
DIRECTORY HEADERCustom fabricated cabinet with a silk-screened header. Header should surface align with with angled metallic silver decorative header above.
DIRECTORY CABINETAPCO FullView Large Assembly sign - horizontal configuration with vertical divider bar. Mounted to central support, signs should be flush with Header above. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.3’-9”w x 2’-5”h
Custom fabricated cabinet with vinyl symbol. Cabinet is double-sided.
D-1 MAIN DIRECTORY, FREESTANDING, w/HANDHELD MAPScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
23
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S
2"
3 1/2"
1/4"
5'-2"
~6"
5"2 1/2"
1/2"1/2"
9"
2 1/2"
1 3/4"
2 1/2"
1/4"
1/4"
1/2"
7'-2"
3 1/4" 4 1/4"2"2 3/4"
7"2 3/4"
1 3/4"8"
5 1/4"
~2'-5"~2'-3"
~2'-5"~1'-6"
3"
3/4"
9"
2'-5"
3'-9 1/8"
1 1/4"
9"
1'-3 1/8"
6 5/8"
LEFT SIDE VIEW RIGHT SIDE VIEW
TOP VIEW
DIRECTORYMyriad Pro Semibold Condensed, kerning set for Optical at 200%
FOOTERMyriad Pro Condensed, all capital letters, kerning set for Optical at 100%
D-1 MAIN DIRECTORY, FREESTANDING, w/HANDHELD MAP DETAILScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
24
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S
1" 3"
5'-2"
1/4"
1/4"
1/2"
2"
4"
H O S P I TA L • M A R Q U A M H I L L C A M P U S
RIGHT SIDE VIEW LEFT SIDE VIEW
WALL BRACKETHidden z-bar bracket inset behind support poles.
TOP VIEW
ISOMETRIC VIEW
D I R E C T O R Y
D-1a MAIN DIRECTORY, WALL MOUNTED, w/HANDHELD MAPScale: 1”=1’-0” on an 11” x 17” sheet
DECORATIVE HEADERCustom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted 1/8” off cabinet. 1/8” spacer should not be visible.
DECORATIVE FOOTERCustom fabricated cabinet with painted acrylic panels. Panels should align with insert windows above.
INSTALLATIONSign to be mechanically fastened to wall. Depending on wall condition extra backing may be required to support weight of sign. Recommend using z-bar clips inset behind support poles and mechanical fasteners through APCO FullView Large mounting plate.
DIRECTORY HEADERCustom fabricated cabinet with a silk-screened header. Header should surface align with with angled metallic silver decorative header above.
DIRECTORY CABINETAPCO FullView Large Assembly sign - horizontal configuration with vertical divider bar. Mounted to backer plate, signs should be flush with Header above. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. 3’-9”w x 2’-5”h
HANDHELD MAP HOLDERCustom fabricated cabinet with angled slots to hold folded vertical 8.5” x 11” brochure inserts. Fabricator to engineer insert slots and quantity. Background of cabinet is a painted mesh screen.
3'-10"
ACCENT BARS3/4” (th.) painted aluminum accent bars welded to support poles.
Custom fabricated cabinet with painted custom radius aluminum support poles.
Drawing Revised 6/12/19
25
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S
3'-7 3/4"
3'-9"
3'-8 3/8"
3'-10"
3"
2'-3"
2'-5"
2'-5"1'-6"
5 1/4"
1 3/4"
2 3/4"
3/4"
3"1 1/4"
5'-2"
1/4"
1/4"
1/2"
RIGHT SIDE VIEW LEFT SIDE VIEW
TOP VIEW
D-1a MAIN DIRECTORY, WALL MOUNTED, w/HANDHELD MAPScale: 1”=1’-0” on an 11” x 17” sheet
DIRECTORYMyriad Pro Semibold Condensed, kerning set for Optical at 200%
FOOTERMyriad Pro Condensed, all capital letters, kerning set for Optical at 100%
3 1/2"
2 3/4"
4 1/4" 3 1/4"
Drawing Revised 6/12/19
26
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R YD I R E C T O R Y D I R E C T O R YD I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S P H Y S I C I A N S PAV I L I O N • M A R Q UA M H I L L C A M P U S
4'-6"
6 5/8"
6'-3 1/2"
3'-9"2"
2'-5"
SIDE VIEW SIDE VIEW
TOP VIEW
D-2 MAIN DIRECTORY, FREE STANDINGCustom fabricated cabinet with painted aluminum poles. Decorative angled fins painted silver metallic and champagne metallic. Header is painted with 1/4” thick acrylic white letters. Footer is an insert behind an acrylic window. Map and destination listings are contained within a cabinet with two acrylic window faces. Acrylic windows are removed by pushing up into reveals notched into the top of the cabinet. Physician directory has only one acrylic window.
SPECIFICATIONSSee D-1 Main Directory for additional fabrication specifications.
D-2 MAIN DIRECTORY, FREESTANDINGScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
27
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S
1" 3"
D I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S
D-2a MAIN DIRECTORY, WALL MOUNTEDScale: 1”=1’-0” on an 11” x 17” sheet
RIGHT SIDE VIEW LEFT SIDE VIEW
WALL BRACKETHidden z-bar bracket inset behind support poles.
TOP VIEW
DECORATIVE HEADERCustom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted 1/8” off cabinet. 1/8” spacer should not be visible.
DIRECTORY HEADERCustom fabricated cabinet with a silk-screened header. Header should surface align with with angled metallic silver decorative header above.
ACCENT BARS3/4” (th.) painted aluminum accent bars welded to support poles.
DIRECTORY CABINETAPCO FullView Large Assembly sign - horizontal configuration with vertical divider bar. Mounted to backer plate, signs should be flush with Header above. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. 3’-9”w x 2’-5”h
Non-illuminated inserts will minimally be printed at 1200 DPI using pigment-based UV inks on a white, satin finish UV-coated photo paper, with a matte UV over-laminate (unless otherwise noted in the design intent drawings). The thickness of the photo paper must be heavy enough such that no wrinkles or waves will occur once installed into the sign housings. If necessary, rigid backers may be used. DECORATIVE FOOTERCustom fabricated cabinet with painted acrylic panels. Panels should align with insert windows above.
INSTALLATIONSign to be mechanically fastened to wall. Depending on wall condition extra backing may be required to support weight of sign. Recommend using z-bar clips inset behind support poles and mechanical fasteners through APCO FullView Large mounting plate.
3'-10"
Custom fabricated cabinet with painted custom radius aluminum support poles.
Drawing Revised 6/12/19
4'-5 1/2"
4'-5 1/2"
1/4"
1/4"
1/2"
2"
4"
3'-9"
3'-7 3/4"
3"3 1/2"
3'-8 3/8"
4 1/4" 3 1/4"
7"
2'-4 3/4"
3"
1'-5 1/2" 2'-3 1/2"
28
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R YD I R E C T O R Y
O H S U H O S P I TA L • M A R Q UA M H I L L C A M P U S
4 1/2"
5'-1"
5'-3"
3'-1 1/4"
2'-5"
5 3/4"
SIDE VIEW
Custom cabinet fabricated out of 1/8” (th.) painted aluminum with painted 3 1/2” round support poles with beveled top edges.
DECORATIVE HEADERCustom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted 1/8” off cabinet. 1/8” spacer should not be visible.
DECORATIVE FOOTERSilk-screened footer and graphics.
DIRECTORY HEADERHeader fabricated out of 1/8” (th.) aluminum silk-screened (or mask and spray) copy and graphics.
DIRECTORY CABINETAPCO FullView Large Assembly sign - horizontal configuration with vertical divider bar. Inset flush to the surface of the sign. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.Units are the same size as the D-1 and D-1a3’-9”w x 2’-5”h
D-2b MAIN DIRECTORY, FREESTANDING, ANGLED, w/HANDHELD MAPScale: 1”=1’-0” on an 11” x 17” sheet
TOP VIEW
HANDHELD MAP HOLDERSCustom fabricated cabinet with
angled slots (flush to the surface of the cabinet to hold folded vertical
8.5” x 11” brochure inserts. Fabricator to engineer insert slots and
quantity.
2'-3"
BASEPLATESMin. 3/4” (th.) aluminum base (to match accent bars)with chemset studs stainless steel studs and hardware.
Drawing Revised 6/12/19
29
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R Y
H AT F I E L D R E S E A R C H C E N T E R
~1'-1 3/4"
2"3 3/4"
1'-9 1/2"
MAX. 5'-0"
1'-4 3/8"2'-6"
2'-5 1/2"
3 1/2"
1'-8 5/8"
1'-7 3/8"
2'-5"
3"
5"
3/4"
3 1/8" 2 1/8" 2"1"
2'-2"
2'-2" 12" (shown angled)
1'-6"
1'-6"
1'-6"
2'-5"
2"1/4"4 1/2"
1 1/4"
SIDE VIEW FRONT VIEW
DIRECTORYMyriad Pro Semibold Condensed, kerning set for Optical at 200%
FOOTERMyriad Pro Condensed, all capital letters, kerning set for Optical at 100%
D-2d MAIN DIRECTORY, FREESTANDING, TALL-ANGLEDScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
30
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R YD I R E C T O R Y
H AT F I E L D R E S E A R C H C E N T E R
~1'-1 3/4"
1'-9 1/2"
MAX. 5'-0"
1'-4 3/8"
2'-6"2'-5 1/2"
3 1/2"
1'-8 5/8"
1'-7 3/8"
2'-5"
3"
Top VIEW
DECORATIVE HEADERCustom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted 1/8” off cabinet. 1/8” spacer should not be visible.
DECORATIVE FOOTERSilk-screened footer and graphics.
SUPPORT POLES3 1/2” round support poles with beveled top edges.
DIRECTORY HEADERHeader fabricated out of 1/8” (th.) aluminum silk-screened (or mask and spray) copy and graphics.
DIRECTORY CABINET UPPER UNITAPCO FullView Standard Assembly signs - horizontal configuration, mounted in a painted aluminum cabinet, flush with surface. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.FVS1826(H)
DIRECTORY CABINET LOWER UNITSimilar construction to upper unitFVS1226(H)
D-2d MAIN DIRECTORY, FREESTANDING, TALL-ANGLEDScale: 1”=1’-0” on an 11” x 17” sheet
BASEPLATESMin. 3/4” (th.) aluminum base (to match accent bars)with chemset studs stainless steel studs and hardware.
Custom cabinet fabricated out of 1/8” (th.) painted aluminum with painted 3 1/2” round support poles with beveled top edges.
Drawing Revised 6/12/19
31
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R Y
H AT F I E L D R E S E A R C H C E N T E R
~1'-1 3/4"
2"3 3/4"
1'-9 1/2"
MAX. 5'-0"
1'-4 3/8"2'-6"
2'-5 1/2"
3 1/2"
1'-8 5/8"
1'-7 3/8"
2'-5"
3"
5"
3/4"
3 1/8" 2 1/8" 2"1"
2'-2"
2'-2" 12" (shown angled)
1'-6"
1'-6"
1'-6"
2'-5"
2"1/4"4 1/2"
1 1/4"
SIDE VIEW FRONT VIEW
DIRECTORYMyriad Pro Semibold Condensed, kerning set for Optical at 200%
FOOTERMyriad Pro Condensed, all capital letters, kerning set for Optical at 100%
D-2d MAIN DIRECTORY, FREESTANDING, TALL-ANGLEDScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
32
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R YD I R E C T O R Y
S A M J A C K S O N H A L L • M A R Q UA M H I L L C A M P U S
3'-9 5/8"
3'-9 5/8"
3'-7"
2'-1 3/4"
3"
7"
1/4"
1/8"
3/4"
1/4"
3/4”
APCO FullView Large Assemblysigns - horizontal configurationMechanically fastened to wall
1/4” (th.) continuous lightweight backer. Inset 1/8” from all edges
3/4” (th.) aluminum accent bar,mechanically fastened to backer.
3/4” (th.) acrylic header, VHB tapedto backer. Edges painted to matchface.
1/4” (th.) painted acrylic panel spaced 1/8” off background
1/8” (th.) spacer
LEFT SIDE VIEW RIGHT SIDE VIEW
CONSTRUCTIONDETAIL
TOP VIEW
Custom fabricated cabinet, see details below.
DECORATIVE HEADERCustom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted 1/8” off cabinet. 1/8” spacer should not be visible.
DECORATIVE FOOTER3/4” (th.) painted acrlyic header with silk-screened copy and graphics. Edges painted to match face. VHB taped to backer plate.
DIRECTORY HEADER3/4” (th.) painted acrlyic header with silk-screened copy and graphics. Edges painted to match face. VHB taped to backer plate.
DIRECTORY CABINETAPCO FullView Large Assembly sign - horizontal configuration with vertical divider bar. Mounted to backer plate, signs should be flush with Header above. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. 3’-9”w x 2’-13/4”h
D-2c MAIN DIRECTORY, WALL MOUNTED, SIMPLIFIEDScale: 1”=1’-0” on an 11” x 17” sheet
INSTALLATIONSign to be mechanically fastened to wall through APCO FullView Large mounting plate.. Depending on wall condition extra backing may be required to support weight of sign.
ACCENT BARS3/4” (th.) painted aluminum accent bars mechanically fastened to backer plate.
Drawing Revised 6/12/19
33
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R Y
S A M J A C K S O N H A L L • M A R Q UA M H I L L C A M P U S
2 3/4"5 1/4"
1 3/4"
3'-9 5/8"
3'-7 3/4"
3'-9 1/8"
3/4"
3" 1 1/4"
2'-1 3/4"
2'-3"1'-6"
3'-9 5/8"
3'-7"
4 1/4"
3/4"
3/4"
7"
2'-1 3/4"
3"
3/4"
3/4"
DIRECTORYMyriad Pro Semibold Condensed, kerning set for Optical at 200%
FOOTERMyriad Pro Condensed, all capital letters, kerning set for Optical at 100%
D-2c MAIN DIRECTORY, WALL MOUNTED, SIMPLIFIED DETAILScale: 1”=1’-0” on an 11” x 17” sheet
LEFT SIDE VIEW RIGHT SIDE VIEW
TOP VIEW
Drawing Revised 6/12/19
34
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D I R E C T O R YD I R E C T O R Y
B A I R D H A L L • M A R Q UA M H I L L C A M P U S
3'-7"
2'-1 3/4"
3"
7"
3'-4 1/4"
3'-3 5/8"
3'-2 3/8"
1/4"
1/8"
3/4"
1/4"
3/4”
APCO FullView Large Assemblysigns - horizontal configurationMechanically fastened to wall
1/4” (th.) continuous lightweight backer. Inset 1/8” from all edges
3/4” (th.) aluminum accent bar,mechanically fastened to backer.
3/4” (th.) acrylic header, VHB tapedto backer. Edges painted to matchface.
1/4” (th.) painted acrylic panel spaced 1/8” off background
1/8” (th.) spacer
LEFT SIDE VIEW RIGHT SIDE VIEW
CONSTRUCTIONDETAIL
TOP VIEW Custom fabricated cabinet, see details below.
DECORATIVE HEADERCustom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted 1/8” off cabinet. 1/8” spacer should not be visible.
DIRECTORY HEADER3/4” (th.) painted acrlyic header with silk-screened copy and graphics. Edges painted to match face. VHB taped to backer plate.
ACCENT BARS3/4” (th.) painted aluminum accent bars mechanically fastened to backer plate.
DIRECTORY CABINETAPCO FullView Large Assembly sign - horizontal configuration with vertical divider bar. Mounted to backer plate, signs should be flush with Header above. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. 3’-9”w x 2’-13/4”h
DECORATIVE FOOTER3/4” (th.) painted acrlyic header with silk-screened copy and graphics. Edges painted to match face. VHB taped to backer plate.
INSTALLATIONSign to be mechanically fastened to wall through APCO FullView Large mounting plate.. Depending on wall condition extra backing may be required to support weight of sign.
SPECIFICATIONSSee D-2c Main Directory for additional fabrication specifications.
D-2f MAIN DIRECTORY, WALL MOUNTED, SIMPLIFIEDScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
35
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-3a ELEVATOR DIRECTORYScale: 1”=1’-0” on an 11” x 17” sheet
Scale: 2”=1’-0” on an 11” x 17” sheet
Floor 10
MULTNOMAHELEVATORA
Floor 10
MULTNOMAHELEVATORA
Floor 1
SAM JACKSONELEVATOR
Floor 1
PHYSICIANS PAVILIONELEVATOR
Floor 3
DOERNBECHERELEVATOR
A
Floor 10
MULTNOMAHELEVATORA
PHYSICIANS PAVILIONELEVATOR
4 1/4"
3 1/4"
6 5/8"
1 3/8"
1 1/4"
1 3/8"
1 1/4"
SIDE VIEW FRONT VIEW
HEADER AND FOOTER DETAILS
To matchthicknessof APCO
sign frame,approx 1/2”.
TOP VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic, inset 1/4” from edges
HEADER:Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
CABINET:APCO FullView FVS2418(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
FOOTER: Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
HEADER FONT:Myriad Pro Semibold Condensed @ 25% kerning. Set for Optical kerning. Text is in all capital letters.
FOOTER FONT:Myriad Pro Condensed @ 25% kerning. Set for Optical kerning.
1 3/8"
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Drawing Revised 6/12/19
LAYOUT EXAMPLES
1/8"
2'-7 1/2"
5"
2'-0"
2 1/2"
1'-6"1/2"1/8"
36
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-3b ELEVATOR DIRECTORY, INSIDE CABScale: 1”=1’-0” on an 11” x 17” sheet
D-3c ELEVATOR DIRECTORY, INSIDE CABScale: 1”=1’-0” on an 11” x 17” sheet
D-3e PHYSICIAN DIRECTORYScale: 1”=1’-0” on an 11” x 17” sheet
Use this elevator to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
Orthopedics 10
Ultra Sound 10
DESTINATION FLOOR
Use this elevator to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
DESTINATION FLOOR
1-0"
PHYSICIANS LISTINGCafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
Orthopedics 10
Ultra Sound 10
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
Orthopedics 10
Ultra Sound 10
SIDE VIEW
TOP VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic, inset 1/4” from edges.
SIGN FRAME:APCO FullView FVL2524(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
BACKER PLATE: Constructed from 1/8" (th.) acrylic, inset 1/4” from edges.
SIGN FRAME:APCO FullView FVS1212(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
BACKER PLATE: Constructed from 1/8" (th.) acrylic, inset 1/4” from edges.
SIGN FRAME:APCO FullView FVS2212(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
TOP VIEW TOP VIEW
Drawing Revised 6/12/19
1'-0"
1'-10"
5/8"1/8"
1/2"1/8"
1'-0"
4"
2'-1"
2'-0"
1/2"1/8"
37
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-3b ELEVATOR DIRECTORY, INSDIE CAB, DETAILScale: 1”=1’-0” on an 11” x 17” sheet
D-3c ELEVATOR DIRECTORY, INSIDE CAB DETAILScale: 1”=1’-0” on an 11” x 17” sheet
D-3e PHYSICIAN DIRECTORY DETAILScale: 1”=1’-0” on an 11” x 17” sheet
1'-0"
2'-1/4"
1'-0" 2'-0"
2'-3/8"
1'-0"
SquareFVS
.265"
Drawing Revised 6/12/19
38
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-3f CUSTOM ELEVATOR DIRECTORYScale: 1”=1’-0” on an 11” x 17” sheet
Floor 3
G HATFIELD ELEVATOR
SIDE VIEW
To matchthicknessof APCO
sign frame,approx 1/2”.
TOP VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic, inset 1/4" from edges
HEADER:Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
CABINET:Custom 32" x 10 1/2" APCO FullView sign frame with square edges - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
FOOTER: Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
FRONT VIEW
Use these elevators to access the following destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
DESTINATION FLOOR DESTINATION FLOOR
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hospital Administration 8
Information 9
Drawing Revised 6/12/19
1/8"
5"
2 1/2"
1/2"1/8"
10 1/2"1'-6"
2'-8"
39
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-3f CUSTOM ELEVATOR DIRECTORY DETAILSPECIFICATION DETAILSScale: 2”=1’-0”
Floor 3
HATFIELD ELEVATORG
Floor 3
5"
2 1/2"
4 1/4"
3 1/4"
6 5/8"
HATFIELD ELEVATORG 1 3/4"2"
SquareFVS
.265"
APCO FULLVIEWLarge Assembly Sign - Horizontal Configuration
HEADER FONT:Myriad Pro Semibold Condensed @ 25% kerning. Set for Optical kerning. Text is in all capital letters.
FOOTER FONT:Myriad Pro Condensed @ 25% kerning. Set for Optical kerning.
1 3/8"
Drawing Revised 6/12/19
5/8"
1/8"
2'-8"
1'-6 1/2"
11"
40
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-3g ELEVATOR DIRECTORYScale: 1”=1’-0” on an 11” x 17” sheet
Scale: 2”=1’-0” on an 11” x 17” sheet
Floor 1
SCHOOL OF NURSINGELEVATOR
Floor 1
SCHOOL OF NURSINGELEVATOR
Floor 1
SCHOOL OF NURSINGELEVATOR
1 3/8"
1 1/4"
1'-4 1/2"
1'-4 1/2"
SIDE VIEW FRONT VIEW
HEADER AND FOOTER DETAILS
To matchthicknessof APCO
sign frame,approx 1/2”.
TOP VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic, inset 1/4” from edges
HEADER:Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
CABINET:APCO FullView FVS2416.5(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
FOOTER: Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
HEADER FONT:Myriad Pro Semibold Condensed @ 25% kerning. Set for Optical kerning. Text is in all capital letters.
FOOTER FONT:Myriad Pro Condensed @ 25% kerning. Set for Optical kerning.
1 3/8"
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Drawing Revised 6/12/19
1/8"
2'-7 1/2"
5"
2'-0"
2 1/2"
1/2"1/8"
41
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-4b STRIP MAP w/GUIDE INFOScale: 1”=1’-0” on an 11” x 17” sheet
D-4c STRIP MAPScale: 1”=1’-0” on an 11” x 17” sheet
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
DoernbecherChildren’sHospital
Hatf ieldResearch Ctr
KohlerPavilion
Tram
You are in the Hospital Floor 9
SIDE VIEW
You are in the Hospital Floor 9
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
You are in the Hospital Floor 9 You are in the Hospital Floor 9
BACKER PLATE:1/8” Acrylic panel mounted to the wall.
SIGN FRAME:APCO FullView FVS2234(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
FOOTER: Acrylic panel with silk-screened graphics. Panel surface to be flush with decorative header and cabinet above.
See guide detail page for sections and specifications.
Similar construction to D-4b SIGN FRAME:APCO FullView FVS2224(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
TOP VIEWTo match thickness
of APCO sign frame,aprox 3/8”
Drawing Revised 6/12/19
2'-10"
2'-0"10" 2'-0"1'-11 1/2"
2'-9 1/2"
1/8"
1'-10 1/2"
2 3/8"
2'-7/8"
42
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
D-5 BUILDING/FLOOR TRANSITION SIGN, WALL-MOUNTEDScale: 1”=1’-0” on an 11” x 17” sheet
TOP VIEW
SIDE VIEW
CONSTRUCTION:Sign is fabricated from 1/4" (th.) painted Komacel panel with 1/4" (th.) painted acrylic accent bars. Letters are 1/4" (th.) acrylic painted white.
Size may vary from location to location. Corbin to provide an estimate for size. Fabricator to verify width on-site prior to fabrication.
H AT FI E L D R E S E A R C H C E N T E R M U LT N O M A H PAV I L I O N • F L O O R 3
D O E R N B E C H E R C H I L D R E N ’ S H O S P I TA L
D O E R N B E C H E R C H I L D R E N ’ S H O S P I TA L
M U LT N O M A H PAV I L I O N • F L O O R 3
3 1/4" 2 3/4"
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
43
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Directories
GUIDES
44
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
G-2 GUIDE SIGN, LARGE Scale: 1”=1’-0” on an 11” x 17” sheet
Floor 1
Library ResearchAdministration
To OHSU HospitalTo Parking Garage
Floor 3
Center for OphthalmicOptics and Lasers
Use phone to contactyour party beforeringing the bell.
Floor 1 Floor 5
Elks Children’s Eye Clinic-Opthalmic Genetics-Translational Clinical TrialsOculofacial Plastic and Reconstructive SurgeryRestroom
Floor 8
8C Cardiac/Surgical ICUHospital Elevator
Rehabilitation Therapy-Physicial Therapy-Occupational Therapy-Speech Therapy
Floor 4
Casey Vision CorrectionCornea ServicesPhotography/UltrasoundRestroomRetina/InflammatoryDiseasePatient Education Ctr
Parking Garage ElevatorTo Tram
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS2218(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER: Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
TOP VIEWTo match thickness
of APCO sign frame,aprox 3/8”
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
1/8"
1'-6"
1'-10 1/2"
2 1/2"
2'-1"
C
45
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Guides
G-2 GUIDE SIGN, LARGE, DETAILSPECIFICATION DETAILSScale: 2”=1’-0”
Scale: 1 1/2”=1’-0”
Floor 9
Hospital Administration
Conference Room 9D53Marquam CaféRestroomTo OHSU Hospital
TYPICAL DESTINATION TEXT:Myriad Pro Semibold Condensed, 1” cap @
25% kerning, set for optical display. Some destinations will require 5% or 10%
kerning.
HOSPITAL ADMINISTRATION TEXT:Myriad Pro Semibold Condensed @ 5% kerning,
set for optical display.
CONFERENCE ROOM 9D53 TEXT:Myriad Pro Semibold Condensed @ 10% kerning,
set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
APCO FULLVIEWAPCO FullView FVS2218(H)MF - horizontal configuration
Drawing Revised 6/12/19
SquareFVS
.265"
Floor 9 Floor 9
Floor 9Floor 9
EMERGENCY Elevator
Conference Room 9D53Hatfield ElevatorHospital AdministrationMarquam CaféRestroom
Conference Room 9D53Hatfield ElevatorHospital AdministrationRestroom
Hatfield ElevatorHospital ElevatorTramTo OHSU Hospital
Kohler OutpatientElevator (Access to Parking)
Patient/Family LoungePatient Rm 9020-9144
Kohler InpatientElevatorPatient Rm 9020-9144To OHSU HospitalTram
G
EB
G
3"
1/8"2 1/2" 1 3/8"
1 3/4"
1 1/2"
1 3/4"
1 3/4"
7/8"
1 1/2"1 1/4"
3 1/2"
7/8"
2 1/8"
1 1/2"
2 1/8"
1 3/4"
1"1 7/8"
1 1/2"
1 1/8"
1 1/4"
3 3/8"
1"
3 1/4"
1 3/4"
1"
1'-6"
1'-10"
2'-1"
46
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Guides
G-2a GUIDE SIGN, MEDIUM Scale: 1”=1’-0” on an 11” x 17” sheet
G-2b GUIDE SIGN, SMALL Scale: 1”=1’-0” on an 11” x 17” sheet
Floor 2
Floor 5
Floor 2
Movement DisordersProgramParkinson Center of OR
To Multnomah Pavilion
Floor 5
Division of VascularSurgeryMultnomah Elevator
Floor 8
EMERGENCY Check-In
1'-5"
TOP VIEW
SIDE VIEW
To match thicknessof APCO sign frame,
approx 3/8”TOP VIEW
SIDE VIEW
To match thicknessof APCO sign frame,
approx 3/8”
P3
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS1818(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER: Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
SIGN FRAME:APCO FullView FVS1418(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
P3
Drawing Revised 6/12/19
EXAMPLE LAYOUT
1/8" 1/8"
1'-6"
1'-6 1/2"
2 1/2"
1'-9"
1'-6"
A
47
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Guides
G-3 GUIDE SIGN, FREESTANDING Scale: 1”=1’-0” on an 11” x 17” sheet
Kohler OutpatientElevatorPatient Rm 9020-9144To Parking Garage
Floor 9
Kohler OutpatientElevatorPatient Rm 9020-9144To Parking Garage
Floor 9
BACK OF CABINET w/o INSERT
SIDE VIEW
TWO LINEDESTINATION:The destination followinga two lined destination should be 2 3/8” from baseline to baseline. This is only for destinations following a two line destination. All others arespaced 2” from baseline to baseline.
TYPICAL DESTINATION TEXT:
Myriad Pro Semibold Condensed @ 25% kerning, set for optical display. Some
destinations will require 0% to 10% kerning.
FOOTER FONT:Myriad Pro Condensed @ 20% kerning. Kerning set for Optical.
FREESTANDING GUIDE:Double-sided freestanding guide sign fabricated out of 1/8” (th.) painted aluminum. DIRECTORY CABINET:APCO FullView Large Assembly sign - horizontal configuration with vertical divider bar. Mounted to central support, signs should be flush with Header above. Large format printed inserts sit behind matte acrylic lens. Inserts should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.1’-6”w x 2’-2”h
ACCENT BARS:1/2” (th.) aluminum bars mechanically fastened (or welded ) to the cabinet.
REMOVABLE BASE:Lower kickplate is removable (by counter-sunk screws on the side of the kiosk) to reveal mounting hardware. Fabricator to engineer sign mounting (must be secured to the floor).
Drawing Revised 6/12/19
2'-2"
2 3/8"1/2"
1'-6"
1'-6 3/4"
3'-2"
1/2"2 1/2"
4 1/2"
2'-6 1/2"
5'-7 3/8"
2"
3 1/2"
5/8"1/8"
4 1/4"
2 3/8"1 5/8"
3" 1"2"
1 5/8"
48
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Guides
OVERHEADS
49
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
HospitalElevator
HospitalElevator
1'-4 1/2"
HospitalElevator
3 1/8"
1'-4 1/2"
approx10"
Waiting
1'-4 1/2"
approx10"
O-1b PROJECTING IDENTIFIER, LARGE, WALL MOUNT
O-1a,b OVERHEAD, PROJECTING ID/GUIDEScale: 1”=1’-0” on an 11” x 17” sheet
HospitalElevator
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS10165(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS10165(H)CMW. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
FONT:Myriad Pro SemiBold Condensed optical kerning @ 25%.
3 3/4"
2 1/4"
3/4"
1 5/8"
6 1/2"
3 3/4"2 1/4"
3/4"
O-1a PROJECTING IDENTIFIER, LARGE, CEILING MOUNT
EXAMPLE LAYOUTS
Drawing Revised 6/12/19
3 1/8"
1'-4 1/2"
approx10"
10"
10"
50
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
CODECART
CODECART
6"
9"
8"
O-1c PROJECTING IDENTIFIER, MEDIUM, CEILING MOUNT
EXAMPLE LAYOUTS
O-1d PROJECTING IDENTIFIER, MEDIUM, WALL MOUNT
O-1c,d OVERHEAD, PROJECTING ID/GUIDEScale: 1”=1’-0” on an 11” x 17” sheet
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
P15
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0809(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
NOTE:This sign is required by OHSU at Code Cart locations. Wall mount or ceiling mount as needed.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0809(H)C-MW Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
Drawing Revised 6/12/19
8"
9"
8"
9"
8"
9"
2 1/4"
51
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
4
4
4 4 1/2"
1/4"
46"
6"
NOTE:This sign is required by OHSU at all fire extinguisher locations. Wall mount or ceiling mount as needed.
O-1e PROJECTING IDENTIFIER, SMALL, CEILING MOUNT
EXAMPLE LAYOUTS
O-1f PROJECTING IDENTIFIER, SMALL, WALL MOUNT
O-1e,f OVERHEAD, PROJECTING ID/GUIDEScale: 1”=1’-0” on an 11” x 17” sheet
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0606(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0606(H)C-MW. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
3 5/8"
Drawing Revised 6/12/19
6"
6"
6"
6"
52
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
1'-3"
1'-3"
E
E
E
5 1/4"
O-1g,h OVERHEAD, PROJECTING ID/GUIDEScale: 1”=1’-0” on an 11” x 17” sheet
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0815(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
O-1h PROJECTING IDENTIFIER, WALL MOUNT
O-1g PROJECTING IDENTIFIER, CEILING MOUNT
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0815(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
6"
5/8"
6"
5/8"
Drawing Revised 6/12/19
8"
8"
E
53
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
Patient Education Center
Casey Eye Elevator Casey Eye Elevator Casey Eye Elevator
4D MRI Waiting 4D MRI Waiting
Casey Eye Elevator
O-2 OVERHEAD IDENTIFIER/GUIDE, DOUBLE-SIDED, CEILING MOUNTED FLUSH
MOUNTING EXAMPLES
OR
O-2 OVERHEAD IDENTIFIER/GUIDE, DOUBLE-SIDED, CEILING MOUNTED SUSPENDED
O-2 OVERHEAD IDENTIFIER/GUIDE, DOUBLE-SIDED, CEILING MOUNTED
O-2 OVERHEAD IDENTIFIER/GUIDE, DOUBLE-SIDED, CEILING MOUNTED
Insert with symbol
Insert without symbol
O-2a OVERHEAD IDENTIFIER/GUIDE, SINGLE-SIDED, WALL MOUNTEDO-2a OVERHEAD IDENTIFIER/GUIDE, SINGLE-SIDED, WALL MOUNTED
O-2, O-2a OVERHEAD ID/GUIDESScale: 1”=1’-0” on an 11” x 17” sheet
Patient Education Ctr
P6
P6
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0848(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0848(H)CMW. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0848(H). Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
Drawing Revised 6/12/19
4'-0"
8"
4'-0"
8"
4'-0"
8"
54
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
Casey Eye Elevator
Check-in and Reception
Photography/Ultrasound
4'-0"
3"
OHSU Sleep Disorders Prog
5" 3"
3"
3"
O-2, O-2a OVERHEAD ID/GUIDE DETAILScale: 1”=1’-0” on an 11” x 17” sheet
Casey Eye Elevator
FONT:Myriad Pro Semibold Condensed @ 25% kerning.
FONT:Myriad Pro Semibold Condensed @ 25% kerning.
FONT:Myriad Pro Semibold Condensed @ 25% kerning.
FONT:Myriad Pro Semibold Condensed @ 5% kerning.
3 1/4" 2 3/4"
3"
6"
4'-0"
Hatfield Research Center
FONT:Myriad Pro Semibold Condensed @ 25% kerning.
3 1/4" 2 3/4"
3"
6"
4'-0"
FONT:Myriad Pro Semibold Condensed @ 5% kerning.
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
5"
2"
55
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
2 1/4"
4 3/8"
Elevator to ParkingTo OHSU Hospital
Elevator to ParkingTo OHSU Hospital
EMERGENCY ElevatorHatfield Elevator
North Café
Elevator to ParkingTo OHSU Hospital
Elevator to ParkingTo OHSU Hospital
North Café
3 5/8"
E
To OHSU Hospital
Gastroenterology Faculty & ResearchPulmonary and Critical Care Medicine
O-3 OVERHEAD GUIDE, DOUBLE-SIDED, CEILING MOUNTED FLUSH
OR
O-3 OVERHEAD GUIDE, DOUBLE-SIDED, CEILING MOUNTED SUSPENDED
O-3 GUIDE, LARGE, DOUBLE-SIDED, CEILING MOUNTED EXAMPLE LAYOUTS
O-3a OVERHEAD GUIDE,LARGE, DOUBLE-SIDED, CEILING MOUNTED
O-3a OVERHEAD GUIDE, LARGE, SINGLE-SIDED, WALL MOUNTED
O-3 & O-3a OVERHEAD GUIDESScale: 1”=1’-0” on an 11” x 17” sheet
EMERGENCY Elevator
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS1048(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS1048(H)CMW. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS1048(H). Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
Hatfield Elevator
P6
2 3/4"
2 3/4"
3"
3 1/4"Diagnostic ImagingOrthopaedics and Rehab
FONT:Myriad Pro Semibold Condensed @ 5% kerning.
4"
2 1/2"
2 1/4"
Drawing Revised 6/12/19
10"
4'-0"
2 1/2"
3 5/8"
E
2 1/2"
56
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
O-4a & O-4b PROJECTING ID/GUIDESScale: 1”=1’-0” on an 11” x 17” sheet
KohlerOutpatientElevator
KohlerOutpatientElevator
Down toFloor 1North Café
ConferenceRoom505
1'-6"
KohlerOutpatientElevators
KohlerOutpatientElevators
Down toFloor 1North Café
ConferenceRoom505
4 1/2"
5/8"
2 3/8"
3 1/8"
2 5/8"2 1/8"
7 1/8"
3 3/8"
2 1/4"
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS15165(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS15165(H)CMW. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
O-4a PROJECTING IDENTIFIER/GUIDE, CEILING MOUNTED O-4b PROJECTING IDENTIFIER/GUIDE, WALL MOUNTED
KohlerOutpatientElevator
FONT:Myriad Pro SemiBold Condensed @ 10% kerning.
FONT:Myriad Pro SemiBold Condensed @ 10% kerning.
P6FONT:Myriad Pro SemiBold Condensed @ 10% kerning.
Drawing Revised 6/12/19
1'-3"
1'-3"
57
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
Day Stay Surgery Admit/Waiting
Short Stay UnitTo Sam Jackson Hall
Diagnostic Imaging Rheumatology andImmunology InfusionOrthopaedics and Rehab
1'-7"
4'-6"
10"
6'-0"
Day Stay Surgery Admit/Waiting
Short Stay UnitTo Sam Jackson Hall
Diagnostic Imaging Rheumatology andImmunology InfusionOrthopaedics and Rehab
6 3/8"
2 1/2"4 3/8"
2 3/8"3" 2 3/8"
2 1/8"
4 1/4"
2'-11 1/2"
4"
Multnomah ElevatorA
Multnomah ElevatorA
O-5 OVERHEAD GUIDE, DOUBLE-SIDED, CEILING MOUNTScale: 1”=1’-0” on an 11” x 17” sheet
O-5b OVERHEAD GUIDE, DOUBLE-SIDED, CEILING MOUNTScale: 1”=1’-0” on an 11” x 17” sheet
O-5b OVERHEAD GUIDE, DOUBLE-SIDED, CEILING MOUNTO-5 OVERHEAD GUIDE, DOUBLE-SIDED, CEILING MOUNTED
SIGN:Message panels are fabricated from two 1/4" (th.) painted Komacel panels mounted back-to-back using APCO aluminum mounting bracket with square profile. Sign edges to be painted to match face. Messaging to be surface applied vinyl graphics. Sign top and bottom edges to have break-formed aluminum trim fabricated from .090 (th.) aluminum. Sign is mounted using APCO extruded aluminum mounting bracket.
SIGN:Message panels are fabricated from two 1/4" (th.) painted Komacel panels mounted back-to-back using APCO aluminum mounting bracket with square profile. Sign edges to be painted to match face. Messaging to be surface applied vinyl graphics. Sign top and bottom edges to have break-formed aluminum trim fabricated from .090 (th.) aluminum. Sign is mounted using APCO extruded aluminum mounting bracket.
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
P6
P6
3 5/8"
3 5/8"
Drawing Revised 6/12/19
58
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
O-6 OVERHEAD ID/GUIDE, CEILING MOUNTScale: 1”=1’-0” on an 11” x 17” sheet
O-6a OVERHEAD ID/GUIDE, WALL MOUNT Scale: 1”=1’-0” on an 11” x 17” sheet
Reception3'-0"
8"
Restroom3'-0"
8"
3'-0"
8"
Waiting3'-0"
8"
Reception
Day Stay SurgeryAdmit/Waiting
Day Stay SurgeryAdmit/Waiting
O-6a OVERHEAD IDENTIFIER/GUIDE, SINGLE-SIDED, WALL MOUNTEDO-6 OVERHEAD IDENTIFIER/GUIDE, DOUBLE-SIDED, CEILING MOUNTED
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0836(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0836(H)CMF. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
P6 P6
Drawing Revised 6/12/19
59
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
O-6 OVERHEAD ID/GUIDE CEILING MOUNT DETAILScale: 1”=1’-0” on an 11” x 17” sheet
O-6a OVERHEAD ID/GUIDE, WALL MOUNTED DETAILScale: 1”=1’-0” on an 11” x 17” sheet
Reception3'-0"
8"
Restroom3'-0"
8"Waiting
Day Stay SurgeryAdmit/Waiting
O-6a OVERHEAD IDENTIFIER/GUIDE, SINGLE-SIDED, WALL MOUNTEDO-6 OVERHEAD IDENTIFIER/GUIDE, DOUBLE-SIDED, CEILING MOUNTED
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
Drawing Revised 6/12/19
2 1/4"
2 3/8"
3 1/8"
5 1/8" 3 1/2" 3 1/2"
3 1/2"
60
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Overheads
IDENTIFIERS
61
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
I-1b PRIMARY IDScale: 1”=1’-0” on an 11” x 17” sheet
TOP VIEW
Pharmacy
PHARMAC YHEALTH CONNE
ResearchAdministration
RESEARCH ADMINISTR ATIONHEALTH CONNECTIONS
RESEARCH ADMINISTR ATIONHEALTH CONNECTIONS
MarquamCaféMonday-Friday6:30 a.m. - 2 p.m.
MARQUAM C AFEHEALTH CONNECTIONS
OculofacialPlastic andReconstructiveSurgery
OCULOFACIAL PLASTIC & RECONSTHEALTH CONNECTIONS
9K OrthopaedicSpine
PATIENT ROOMS 9020-9144HEALTH CONNECTIONS
ClinicalNeurophysiology
CLINIC AL NEUROPHYSIOLOGYHEALTH CONNECTIONS
Patient Rooms9020-9144
OHSU/AFSCMECareer WorkplaceEnhancement Center
C AREER WORKPLACEHEALTH CONNECTIONS
Center for Learning &Development
RehabilitationTherapyPhysical TherapyOccupational TherapySpeech Therapy
REHABILITATION THER APYHEALTH CONNECTIONS
1'-2"
2 1/2"3 3/4"
Autonomic, EEG/EMGEvokes Potential,Oken Cognitive, andNeuroscience Lab
PhysicalTherapyTerapia física
PHYSIC AL THER APYHEALTH CONNECTIONS
SIDE VIEW
Insert with symbol Insert without symbol
To matchthicknessof APCO
sign frame
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS8514(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
62
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
I-1b PRIMARY ID DETAILSPECIFICATION DETAILSScale: 2”=1’-0”
MarquamCafé
Monday-Friday6:30 a.m. - 2 p.m.
MARQUAM C AFEHEALTH CONNECTIONS
11K Cardiac/Vascular
PATIENT ROOMS 11006-11140HEALTH CONNECTIONS
Clinical NeurophysiologyEEG/EMGEvokes PotentialOken CognitiveNeuroscience Lab
CLINIC AL NEUROPHYSIOLOGYHEALTH CONNECTIONS
Patient Rooms11006-11140
OHSU/AFSCMECareer WorkplaceEnhancement Center
C AREER WORKPLACEHEALTH CONNECTIONS
Center for Learning andDevelopment
PhysicalTherapyTerapia física
PHYSIC AL THER APYHEALTH CONNECTIONS
2 1/4"
4 1/2"
1 3/8"
1 1/8"
2 1/4"
1 3/8"
3/4"
5/8"
5/8"
1"
3/4"
1 3/8"
2 1/4"5/8"
2 1/2" 2 1/2" 3 3/4"
Pharmacy
PHARMAC YHEALTH CONNE
ResearchAdministration
RESEARCH ADMINISTR ATIONHEALTH CONNECTIONS
OculofacialPlastic andReconstructiveSurgery
OCULOFACIAL PLASTIC AND RECONSTHEALTH CONNECTIONS
1'-2"
3"
3 3/4" 3/4"
1 1/8" 2 3/8"
5/8"3/8" 1/4"
RehabilitationTherapyPhysical TherapyOccupational TherapySpeech Therapy
REHABILITATION THER APYHEALTH CONNECTIONS
5/8"1"
1"
2 1/4"
5 3/8"4 1/2"
2 1/4"
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
HOURS OF OPERATION TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
SUB-SPECIALITY TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
TEXT FOR LONG NAMES:3/4” (h.) Myriad Pro Condensed @ 25% kerning, set for optical display.
PATIENT ROOMS TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
SPANISH TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
Drawing Revised 6/12/19
8 1/2"
2 3/8"
11 3/8"
EXAMPLE LAYOUTS
63
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
Classroom8N124
8 N124SJFGHZSJHGJHG
Clinic A
Rooms A1-A6
C 9 0 0 6 .1SJFGHZSJHGJHG
I-1c CLASSROOM/LAB ID w/ NOTIFIER BARScale: 1”=1’-0” on an 11” x 17” sheet
SIDE VIEW
BACKER PLATE:1/8” thick acrylic panel mounted to the wall.
CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS8514(H)MF. Sign frame is mounted to acrylic backer plate. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Sign footer is flush with surface of sign cabinet. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters painted, Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer plate. Sign footer is flush with surface of sign cabinet.
NOTIFIER BAR:APCO Notifier Message Strip mounted to backer plate, aligned flush with the bottom of the sign. Notifier bar should be the same width of sign cabinet so edges of the bar are flush with the edges of the sign cabinet.
NOTIFIER BAR:APCO Notifier Message Strip mounted to backer plate, aligned flush with the bottom of the sign. Notifier bar should be the same width of sign cabinet so edges of the bar are flush with the edges of the sign cabinet.
To matchthicknessof APCO
sign frame
Classroom8N124
8 N124SJFGHZSJHGJHG
approx 1'-2 "
approx1'-3/4"
Drawing Revised 6/12/19
64
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
Classroom2S040
2S0 4 0HGJHG
approx 1'-2"
8 1/2"
2 1/2"
11 1/2"
approx9"
4"1/8"
1/2"
1 1/8"
I-1c CLASSROOM/LAB ID w/ NOTIFIER BARSPECIFICATION DETAILSScale: 3”=1’-0”
Scale: 3”=1’-0”
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 20% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
5/8"3/8"
1/4"
2 1/2"
4 1/8"1 5/8"
NOTIFIER BAR:APCO Notifier Message Strip mounted to backer plate, aligned flush with the bottom of the sign. Notifier bar should be flush with surface of sign. If necessary, an acrylic spcer can be added to the back of the notifier bar to allow fludh alignment with sign face.
Drawing Revised 6/12/19
65
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
I-1e PRIMARY ID w/LETTER SIZED INSERT HOLDERScale: 1”=1’-0” on an 11” x 17” sheet
If the light is green, pleasecome in.
If the light is red, please pick up the phone and someone will be with you shortly.
Thank you.
TOP VIEW
MarquamCafé
MARQUAM C AFEHEALTH CONNE
RESEARCH ADMINISTR ATIONHEALTH CONNECTIONS
1'-2"
ResearchAdministration
RESEARCH ADMINISTR ATIONHEALTH CONNECTIONS
8 1/2"
1'-2"
2 1/2"3 3/4"
4A AbdominalTransplant andSurgical Specialties
ABDOMINAL TR ANSPLANT/SURG SPECHEALTH CONNECTIONS
Patient Rooms4A4-4A48
If the light is green, pleasecome in.
If the light is red, please pick up the phone and someone will be with you shortly.
Thank you.
PERI-ANESTHESIA C AREHEALTH CONNECTIONS
Doors will be locked from7 p.m. - 5 a.m.
If you need assistance, pleasepick up the phone.
One (1) visitor at a time
Thank you.
Peri-AnesthesiaCare
If the light is green, pleasecome in.
If the light is red, please pick up the phone and someone will be with you shortly.
Thank you.
If the light is green, pleasecome in.
If the light is red, please pick up the phone and someone will be with you shortly.
Thank you.
If the light is green, pleasecome in.
If the light is red, please pick up the phone and someone will be with you shortly.
Thank you.
IRU ADMIT TING/RECOVERYHEALTH CONNECTIONS
Please do not wait in front ofthese doors.
The IRU waiting Room is located in Sam Jackson Hall.
Thank you.
IRU Admitting/Recovery
SIDE VIEW
8 1/2” x 14” paper insert
To matchthicknessof APCO
sign frame
Insert with symbol Insert without symbol
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS8514(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
INSERT FRAME:APCO FullView FVS8514(IA)MF - to allow for 8 1/2” x 14” changeable notice. Frame is mounted to acrylic backer panel. Left side of holder to be filled with painted acrylic panel separated from insert holder by a blocking strip. Notice is changed by inserting a sticky note or similar between the display and non-glare lens then pulling the notice up/out of the frame.
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
1'-8 3/8"
11"3"
66
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
I-1e PRIMARY ID, w/LETTER SIZED INSERT HOLDER DETAILSPECIFICATION DETAILSScale: 2”=1’-0”
MarquamCafé
MARQUAM C AFEHEALTH CONNE
1'-2"3 3/4" 3/4"
2 3/8"
5/8"3/8"
1/4"
1 1/8" 4A AbdominalTransplant andSurgical Specialties
ABDOMINAL TR ANSPLANT/SURG SPECHEALTH CONNECTIONS
Patient Rooms4A4-4A48
If the light is green, pleasecome in.
If the light is red, please pick up the phone and someone will be with you shortly.
Thank you.
PERI-ANESTHESIA C AREHEALTH CONNECTIONS
Doors will be locked from7 p.m. - 5 a.m.
If you need assistance, pleasepick up the phone.
One (1) visitor at a time
Thank you.
Peri-AnesthesiaCare
IRU ADMIT TING/RECOVERYHEALTH CONNECTIONS
Please do not wait in front ofthese doors.
The IRU waiting Room is located in Sam Jackson Hall.
Thank you.
IRU Admitting/Recovery
1/2"7/8"
5/8"
1 3/8"
1 1/8"
7/8"1 1/8"
1 3/8"
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
PATIENT ROOM TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
EXAMPLE LAYOUTS
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
3"
Drawing Revised 6/12/19
8 1/2"
8 1/2"
2 3/8"1'-8 3/8"
1 5/8"
67
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
247 8GJHG
Patient andFamily Lounge
247 8GJHG
8 1/2"
Patient andFamily Lounge
2478GnHG
6"
1/4"
OHSU ParkinsonCenter of Oregonand MovementDisorders Program
2478GnHG
8 1/2"
Population HealthAssessment OfficeA School of NursingKnight Cancer InstituteCollaboration
1020Av1130A
I-2 SECONDARY IDScale: 1”=1’-0” on an 11” x 17” sheet
TOP VIEW
To matchthicknessof APCO
sign frame
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS0685(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
I-2 SECONDARY ID DETAILSPECIFICATION DETAILSScale: 3”=1’-0”
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
SUB-HEADING TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
5/8"
3/8"
1"
1"
1 3/4"3/4"
1 1/8"
Drawing Revised 6/12/19
8 7/8"
1 1/8"
8 7/8"
2 3/8"
1 3/8"
3/4"
1 1/4"
1 1/2"
1/2"
3/4"
8 5/8"
68
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
247 8GJHG
Kenneth C. SwanLibrary
247 8GJHG
Hours:Monday-Thursday8 a.m. - 4 p.m.
Reserved for faculty and staff.
8 1/2"
Kenneth C. SwanLibrary
2478GnHG
I-2a CONFERENCE ROOM ID w/INSERT HOLDERScale: 1”=1’-0” on an 11” x 17” sheet
TOP VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS0685(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
INSERT FRAME:APCO FullView FVS1185(IA)MF - to allow for 8 1/2” x 11” changeable notice. Frame is mounted to acrylic backer panel. Notice is changed by inserting a sticky note or similar between the display and non-glare lens then pulling the notice up/out of the frame.
I-2a CONFERENCE ROOM ID w/NOTICE HOLDERSPECIFICATION DETAILSScale: 3”=1’-0”
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
DESTINATION TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
Hours:Monday-Thursday8 a.m. - 4 p.m.
Reserved for faculty and staff.
1 3/8"
1 1/8"
7/8"
1 3/8"
7/8"
5/8"
Drawing Revised 6/12/19
1'-8 1/2"
2 3/8"
1'-8 1/2"
1"
1 3/4"3/4"
6"
8 1/2"
5/8"
3/8"1/4"
8 5/8"
69
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
6 7 8GJHGVB
1N072CGnHGDVD
approx 8"
1/4"
approx4"
1N072BGnHGDVGH
6 7 8GJHGVB
345v345
TOP VIEW
I-3 GENERAL ROOM IDScale: 1”=1’-0” on an 11” x 17” sheet
To matchthicknessof APCO
sign frame
SIDE VIEW
LogisticsManagement
6 7 8GJHDFG
Office
approx8"
3 4 52478
TOP VIEW
SIDE VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS0408(H) - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
EXAMPLE LAYOUTS
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
5/8"
3/8"
1"
LogisticsManagement
5/8"1 1/4"
1"
I-3 GENERAL ROOM ID SPECIFICATION DETAILSScale: 3”=1’-0” on an 11” x 17” sheet
AdministrativeAssistantLaurie Beam
AdministrativeAssistantLaurie Beam
1 1/4"
1"
1/16"
5/8"
7/8"
3 4 52478
SIDE VIEW
Exam
1Exam
1
5/8" Exam 1 1/4"
1 1/2"
1/2"
1
Drawing Revised 6/12/19
5/8"
~8"
3/8"
4"
2 3/8"
7"7"
2 3/8"
4"
2 3/8"
7"
70
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
6 7 8GJHGVB
NOTIFIER BAR:APCO Notifier Message Strip mounted to backer plate, aligned flush with the bottom of the sign. Notifier bar should be the same width of sign cabinet so edges of the bar are flush with the edges of the sign cabinet.
NOTIFIER BAR:APCO Notifier Message Strip mounted to backer plate, aligned flush with the bottom of the sign. Notifier bar should be the same width of sign cabinet so edges of the bar are flush with the edges of the sign cabinet.
1N072CGnHGDVD 1/4"
approx 8"
approx4"
TOP VIEW
I-3a GENERAL ROOM ID w/ NOTIFIER BARScale: 1”=1’-0” on an 11” x 17” sheet
To matchthicknessof APCO
sign frame
SIDE VIEW
Office
6 7 8GJHDFG
Office
approx8"
3 4 52478
TOP VIEW
SIDE VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS0485(H) - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
Drawing Revised 6/12/19
5/8"
3/8"
AdministrativeAssistantLaurie Beam
1 1/4"
1"
1/16"
5/8"
7/8"AdministrativeAssistantLaurie Beam
~8"
3/8"
4"
2 3/8"
7"7"
2 3/8"
71
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
approx 8"
approx4"
5A23GnHGDV
NOTIFIER BAR:APCO Notifier Message Strip mounted to backer plate, aligned flush with the bottom of the sign. Notifier bar should be the same width of sign cabinet so edges of the bar are flush with the edges of the sign cabinet.
I-4 PATIENT ROOM IDScale: 1”=1’-0” on an 11” x 17” sheet
125A 2 32478
125A 2 32478
TOP VIEW
SIDE VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS0408(H) - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
5/8"
3/8"
I-4 PATIENT ROOM ID SPECIFICATION DETAILSScale: 3”=1’-0” on an 11” x 17” sheet
122"
SquareFVS
.265"
1/4"
I-4a PATIENT ROOM ID w/ NOTIFIER BARScale: 1”=1’-0” on an 11” x 17” sheet
125A 2 32478
TOP VIEW
SIDE VIEW
Drawing Revised 6/12/19
4"
2 3/8"
~8"
3/8"
7"
2 3/8"
4"
2 3/8"
~8"
3/8"
7"
72
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
FACILITIES SVCS WORKSHOP
4 N 0 81BT I S S U E C U LT U R E
FACILITIES SVCS WORKSHOP
4N081BTISSUE CULTURE
8"
4"
3/8"
1N109FACILITIE S SVC SWORK SHOPFACILITIES SVCS WORKSHOP
8"
4"
3/8"
3/8"
5/8"
1"
7/8"
7/8"3/8"
1/4"
SIGN PANEL:3/8” thick painted acrylic panel with tactile and Braille characters. Tactile characters painted white.
I-5 UTILITY IDScale: 1”=1’-0” on an 11” x 17” sheet
TOP VIEW
DESTINATION TEXT:Myriad Pro Condensed, kerning set 75% and optical display.
I-5 UTILITY ID SPECIFICATION DETAILSScale: 3”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
73
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
Leah CuddingtonAssistant
Leah CuddingtonAssistant
approx8 1/2"
approx3 1/2"
Joan McHenryAdministrative Assistant
8 1/2"
approx3 1/2"
I-6 CUBICAL IDScale: 1”=1’-0” on an 11” x 17” sheet
TOP VIEW
SIGN FRAME:APCO FullView FVS3585(V) - vertical configuration, pin to be installed in the upper left position. Sign can be mounted to cubicle with velcro, APCO pin attachment, APCO panel clip attachment, or VHB tape depending on wall surface. Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
NAME:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
TITLE:Myriad Pro Condensed @ 25% kerning, set for optical display.
I-6 CUBICAL IDSPECIFICATION DETAILSScale: 3”=1’-0” on an 11” x 17” sheet
1"
1 1/4"
3/4"
5/8"
1/2"
Drawing Revised 6/12/19
PIN-U
A unique dual-pin feature allows smaller FullView frames to attach to fabric surfaces.
Pin Attachment For Fabric Mounting
Aluminum clips are custom fabricated to specified dimensions and adhered to the back of the FullView frame.
Panel Clip AttachmentFor Office Partitions
Compatible with the following FullView Standard Assembly, Top Access, Inner Access or E-Series frame sizes:
• 3"h x 6"w• 3.5"h x 8.5"w• 4"h x 4"w• 6"h x 4"w
Compatible with the following FullView Standard Assembly, Top Access, Inner Access or E-Series frame sizes:
• 3"h x 6"w• 3.5"h x 8.5"w• 4"h x 4"w• 5.5"h x 8.5"w• 6"h x 4"w• 6"h x 6"w Dimension Min. Max.
A 1/2" 1"B 1" 3"C (Visible) 0" 3"D 2" 4"
A
D
C
B
74
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
I-7 INDIVIDUAL LETTERS, RULE LINEScale: 1 1/4”=1’-0” on an 11” x 17” sheet(unless otherwise noted)
INDIVIDUAL LETTERS:1/4” thick painted acrylic letters and baseline. Letters and baseline to be cut from same piece of acrylic - no seams. Faces, sides and backs of composition are to be painted. Composition is pin-mounted 3/8” off wall. Pins to be painted to match letters. Fabricator to engineer locations for pins. Owner and fabricator to determine final locations and mounting height.
NOTE:Use this sign type only at major public destination desks like Admitting and Information. Not to be used to identify departments or hospital units per directive from Facilities, Hospital Administration, and the Wayfinding Committee.
FONT: Myriad Pro SemiBold Condensed. All capital letters. Text height is stretched to 110%.Kerning set at 100%.
10 1/2"
7"
Drawing Revised 6/12/19
75
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
STANDARD LAYOUT: ALTERNATE LAYOUT:
I-7c INDIVIDUAL LETTERS:1/4” thick acrylic letters painted to match dark gray mounted to 1/4” thick frosted acrylic panel, frosted on first surface. Second surface to be painted white (preferred) or covered with white vinyl (acceptable). Faces, sides and backs of letters are to be painted. Acrylic panel is mounted to wall with brushed aluminum decorative stand-off museum mounts. Fabricator to engineer if additional mounts are necessary. Owner and fabricator to determine final dimensions and mounting height.
FONT:Myriad Pro SemiBold Condensed. All capital letters. Vertical Scale is set to 110% and tracking is set to 50. Initial letter has a 4-3/8” cap height, subsequent letters have a 4-0” cap height.
(SO1625AL) 5/8” x 1” Through Grip Standoffs,Round, Aluminum, Silver
Drawing Revised 6/12/19
I-7c INDIVIDUAL LETTERS, ACRYLIC PANELScale: 1/2”=1’-0” on an 11” x 17” sheet(unless otherwise noted)
4 3/8" 4"
APPROXIMATELY
6 5/8" 6"
APPROXIMATELY
76
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
STANDARD LAYOUT:ALTERNATE LAYOUT:
Drawing Revised 6/12/19
8'-0"
8'-0"8'-0"
8'-0"
8'-0"
4'-0" 4'-0"4'-0"
9'-7"
2'-0"
1'-6"
3'-0"
2'-0" 2'-0"
2'-0"2'-0"
2'-0" 2'-0"
77
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
I-9 RESEARCH BAY IDENTIFIER Scale: 1”= 1” on an 11” x 17” sheet
SIGN PANEL:1/8” thick matte acrylic panel with sub-surface paint and vinyl graphics. 3N068.A1
3N068.A1DESTINATION TEXT:Myriad Pro Condensed, kerning set 75% and optical display.
MOUNTING OPTIONS
PHOTO 1 BACK
OPTION 1
OPTION 2OPTION 2
OPTION 1
4"
1"
5/8"
Drawing Revised 6/12/19
78
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
C E L L A N D D E V E L O P M E N T A L B I O L O G Y
V-1 VINYLScale: 1”=1’-0” on an 11” x 17” sheet
FONT:Myriad Pro SemiBold Condensed. All capital letters and optical kerning.
DETAIL:3M Matte White Opaque vinyl applied to the second surface of glass window. Composition is left justified off 2 1/2” from the window mullion. Sign is mounted to glass window panels.
FONT:Myriad Pro SemiBold Condensed. All capital letters and optical kerning.
DETAIL:3M Matte White Opaque vinyl applied to the second surface of glass window. Composition is left justified off 2 1/2” from the window mullion. Sign is mounted to glass window panels.
M O L E C U L A R A N DM E D I C A L G E N E T I C S
Drawing Revised 6/12/19
1'-10"
2 1/2"
5 3/8"
3 3/8"
1'-10"
2 1/2"
3 3/8" 3 1/16"
3 1/16"
79
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
Parking GarageB U I L D I N G 1
3'-6"
6'-9 7/8"
3'-6"
6'-9 7/8"
Access to Floors 2-16B U I L D I N G 1
2’-6"
1’-3 3/4"
4 1/2"
6"
2 3/8"
3 1/2"
2 3/8"
3 1/2"
1/4"
1/4"
1/4"
10 1/2"
2’-6"
1’-3 3/4"
4 1/2"
6"
1/4"
1/4"
1/4"
10 1/2"
V-3 VINYL ON ELEVATOR DOORScale: 1/2”=1’-0” on an 11” x 17” sheet
3M Dusted Crystal (7725SE-324) vinyl, or equivalent with digitally printed graphics.
“BUILDING 1”Font: Gotham Condensed Book, in all caps, with tracking set at 200. “Parking Garage”Font: Gotham Condensed Book, in upper and lower case, with tracking set at 50.
“BUILDING 1”Font: Gotham Condensed Book, in all caps, with tracking set at 200. “Access to Floors 2-16”Font: Gotham Condensed Book, in upper and lower case, with tracking set at 50.
ALTERNATE LAYOUT:
Symbol to be 3M Dusted Crystal (7725SE-324) vinyl, or equivalent.
P17
P17
Drawing Revised 6/12/19
80
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
Opaque vinyl with digitally applied graphics. Fabricator to field verify door measurements.
Staff OnlyStaff Only
TBD
6'-9 7/8"
3" 6 3/4"
4'-0"
V-4 VINYL ON STAFF ELEVATOR DOORScale: 1/2”=1’-0” on an 11” x 17” sheet
“Staff Only”Font: Gotham Condensed Medium, in upper and lower case, with tracking set at 50.
Drawing Revised 6/12/19
81
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
P216 01"P216 0
3"
V-5 DOOR VINYLScale: 1/2” = 1’-0“ on an 11” x 17” sheet
SIGN PANEL:Self-adhesive white vinyl digitally printed to match black.
DESTINATION TEXT:Myriad Pro Condensed, kerning set 75% and optical display.
Drawing Revised 6/12/19
5/8"
82
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Identifiers
NOTIFIERS
83
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
11"
8 1/2"
11"
8 1/2"
1'-5"
11"
8 1/2"
11"
NOTE:If sign requires easy removal of the printed insert a sign frame with a thumb slot can be specified.
Pleasewaithere
SIDE VIEW
COUNTER TOP MODULE:APCO FullView FVS1185(H) sign. Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
N-1f NOTICE HOLDER
N-1a,b,c,d,e,f,g NOTICE HOLDERSScale: 1”=1’-0” on an 11” x 17” sheet
N-1a NOTICE HOLDER N-1b NOTICE HOLDER N-1c NOTICE HOLDER
TOP VIEW
SIDE VIEW
TOP VIEW TOP VIEW
SIDE VIEW SIGN CABINET:APCO FullView FVS0806(H) sign. Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView FVS8511(H) sign. Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
NOTE:An N-1g sign with the message “Please wait here” is required for all check-in desk locations.
SIGN CABINET:APCO FullView FVS1117(H) sign. Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
N-1e NOTICE HOLDER
N-1g NOTICE HOLDER
TOP VIEW
SIDE VIEW
SIGN CABINET:APCO FullView FVS1711(H) sign. Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
SIGN CABINET:APCO FullView FVS8511(H) sign mounted on a FS301 Vertical Single-sided Pedestal.
Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic
window for optimal appearance.
N-1d NOTICE HOLDER
TOP VIEW
SIGN CABINET:APCO FullView FVS1185(H) sign. Printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
Drawing Revised 6/12/19
1'-5"
11"
6"
8"
11"
8 1/2"
84
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Notifiers
Pleasewaithere
Oregon nurse staf f ing lawsInformation for patients and familiesOHSU complies with the provisions of Senate Bill 469, which created new provisions regardingsuf f icient nurse staf f ing in all Oregon hospitals. The Oregon Health Authority is responsible forenforcing the provisions of Oregon’s nurse staf f ing laws.
Important elements of Oregon’s hospital nurse staf f ing laws that you should know:
• This nursing unit has a staf f ing plan in place to provide for the care needs of its patients.• The staf f ing plan is developed in partnership between the nurses who provide patient care and nurse managers.• The staf f ing plan includes details about the number of nurses as well as the skills and competencies needed to provide safe and quality care for the patients on this unit.
If you have a concern about your care, please bring it to the attention of your nurse, the nursemanager of this unit or OHSU Patient Relations at 503-494-7959. If we’re unable to resolve yourconcern, you may call the Oregon Health Authority’s Health Care Regulation and QualityImprovement division at 971-673-0540, or by email at [email protected].
Visit www.healthoregon.org/hcrqi for more information.
N-1 GENERAL NOTICE HOLDER DETAILSScale: 3”=1’-0” on an 11” x 17” sheet
FONT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
FONT:Typeset as shown.
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
1"
1"
1 1/4"
1 7/8"
8 1/2"
11"
8 1/2"
11"
85
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Notifiers
Please lockthe door.
Please lockthe door.
Cell phones may interfere with patient care equipment.
No cell phones in this area.
8"
8"
8"
Lift Phonefor Assistance
Nearest accessiblerestroom is around
the corner nearElevator A. RADIATION AREA BIOHAZARD
N-2 GENERAL INFORMATIONScale: 1”=1’-0” on an 11” x 17” sheet
SIGN PLAQUE:1/4” Acrylic panel with sub-surface paint and vinyl graphics.
TOP VIEW
SIDE VIEW
Drawing Revised 6/12/19
1/4"
86
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Notifiers
EmergencyExit Only
Staff OnlyAuthorized
Personnel Only
AuthorizedPersonnel
Only
1 1/2"
1 1/2"
7/8"
Please lockthe door.
7/8"
1 1/2"
Cell phones may interfere with patient care equipment.
No cell phones in this area.
Lift Phonefor Assistance
Nearest accessiblerestroom is around
the corner nearElevator A.
2 1/4"
1 1/4"
1"
5/8"
BIOHAZARD
N-2 GENERAL INFORMATION DETAILScale: 3”=1’-0” on an 11” x 17” sheet
FONT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
7/8"
1 1/2"
4"
1 3/4"7/8"
4"
1 3/4"3/4"
4"
1 1/2"
7/8"
4"
1 1/2"
7/8"
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
1 1/8"1/2"1/2"
3 3/4"
1 1/8"
7/8"
87
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Notifiers
Accessible Path to Hospital
1'-0"
1'-0"
Take Elevator toLobby to access
DoernbecherChildren’s Hospital.
FIRECONTROL
ROOMNO PUBLIC ACCESS
AUTHORIZEDPERSONNEL ONLY
USE PHONE FOREMERGENCY
ANDACCESS
To Stairs and Unisex Bike
Locker RoomDental Clinic entrance is near the garage drive entry.
South Elevatorswill not access
the Dental Clinic.
SIGN PLAQUE:1/4” Acrylic panel with sub-surface paint and vinyl graphics.
TOP VIEW
SIDE VIEW
N-2a GENERAL INFORMATIONScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
1/4"
88
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Notifiers
Accessible Path to Hospital
Dental Clinic entrance is near the garage drive entry.
South Elevatorswill not access
the Dental Clinic. To Stairs and
Unisex Bike Locker Room
FIRECONTROL
ROOM
NO PUBLIC ACCESSAUTHORIZED
PERSONNEL ONLY
USE PHONE FOREMERGENCY
ANDACCESS
N-2a GENERAL INFORMATION DETAILScale: 3”=1’-0” on an 11” x 17” sheet
Take Elevator toLobby to access
DoernbecherChildren’s Hospital.
5 1/4"
2 5/8"1 7/8"
1 3/4" 1 1/8"
1 1/8"
1 7/8"
FONT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
Drawing Revised 6/12/19
EXAMPLE LAYOUTS
2"
3 1/4"
1 1/8"
1 7/8"
1 1/4"
5"
7/8"1 1/2"
1 1/4"
1'-0"
1'-0"
1/4"
5/8"
1 1/8"
1 7/8"
3 3/8"
2"
1 7/8"
1 1/4"
89
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Notifiers
All are welcome to use the restroom that aligns with
their gender identity or expression.
All are welcome to use the restroom that aligns with
their gender identity or expression.
All are welcome to use the restroom that aligns with
their gender identity or expression.
Push button below to access unit.
WOMEN2478
NOTE:This sign must be used on all public multi-stall restrooms.
Push button to access unit.
approx 8"
approx4"
R-1
N-3
N-3 GENERAL INFORMATIONScale: 1”=1’-0” on an 11” x 17” sheet
N-3 GENERAL INFORMATIONSPECIFICATION DETAILSScale: 3”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
SquareFVS
.265"
TOP VIEW
SIDE VIEW
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS0408(H) - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
1/2" 1/2"
1/2"
3/4"
2 1/4"
~8"
3/8"
~4 1/2"
90
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Notifiers
REGULATORY
91
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
RESTROOM SIGN STANDARDS:• Gender specific, multi-stalled restrooms must include both the
R-1/R-1a sign and the N-3 sign above it, as well as directions to the nearest unisex/single-user restroom.
• Add directions to the nearest gender-neutral restroom.• Unisex/single user restrooms use the R-1/R-1a only.• Restrooms with changing tables should use the R-1a sign with
the correct symbol and “Changing Table Available” message.• Restrooms that are not accessible must include an N-2.• Tactile and braille messages: Women’s restroom = WOMEN Men’s restroom = MEN Patient restroom = RESTROOM Staff restroom = STAFF RESTROOM Unisex/single stall restroom = RESTROOM• O-1c or O-1d are used at all public restrooms or patient
restrooms (when not located within a patient room).• R-1/R-1a signs use a symbol without the circle.• O-1c/O-1d flag signs use a symbol with the circle.
WOMENWOMEN
All are welcome to use the restroom that aligns with
their gender identity or expression.
R-1
60"
85"
N-3
MENMEN
All are welcome to use the restroom that aligns with
their gender identity or expression.
R-1 R-1a
N-3
N-2
O-1d
Nearest accessiblerestroom is around
the corner nearElevator A.N-2
Single-userrestroom locatednear the Waiting
Room.
RESTROOMRESTROOM R-1
N-2
Nearest accessiblerestroom is around
the corner nearElevator A.
RESTROOM2478
Changing TableAvailable
STAFF RESTROOMSTAFF RESTROOM
All are welcome to use the restroom that aligns with
their gender identity or expression.
R-1
N-3
Drawing Revised 6/12/19
92
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Regulatory
WOMEN2478
EXIT STAIRS2478F 2478
6"
2 3/8" EXIT STAIRS
NOTE:All public multi-stall restrooms must also include an N-3 sign with gender neutral statement. approx 8"
6"
2 1/2"
approx9"
1/4"
WOMEN2478
4"
R-1 REGULATORYScale: 1”=1’-0” on an 11” x 17” sheet
~8"
3/8"
TOP VIEW
SIDE VIEW
CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0608(H)MF. Sign frame is mounted to acrylic backer plate. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Sign footer is flush with surface of sign cabinet. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters painted, Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer plate. Sign footer is flush with surface of sign cabinet.
R-1 REGULATORY DETAILSPECIFICATION DETAILSScale: 3”=1’-0”
Scale: 3”=1’-0”
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
5/8"
3/8"
1"
Drawing Revised 6/12/19
93
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Regulatory
WOMEN2478
Changing TableAvailable
WOMEN2478
Changing TableAvailable
8"
2 3/8" RESTROOM2478
Changing TableAvailable
NOTE:All public multi-stall restrooms must also include an N-3 sign with gender neutral statement. approx 8"
2 1/2"
1/4"
WOMEN2478
4"
2"
Changing TableAvailable
5/8"
8"
R-1a REGULATORYScale: 1”=1’-0” on an 11” x 17” sheet
~8"
3/8"
TOP VIEW
SIDE VIEW
CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS0808(H)MF. Sign frame is mounted to acrylic backer plate. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Sign footer is flush with surface of sign cabinet. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters painted, Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer plate. Sign footer is flush with surface of sign cabinet.
P6
Scale: 3”=1’-0”
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
5/8"
3/8"
1"
R-1a REGULATORY DETAILSPECIFICATION DETAILSScale: 1”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
94
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Regulatory
STAIR 1ROOF ACCESS
91 THROUGH ROOFEXIT THIS LEVEL
R-2 REGULATORY STAIRWELLScale: 1”=1’-0” on an 11” x 17” sheet
1'-0"
1'-6"
TOP VIEW
SIGN PLAQUE:1/4” Photoluminescent (Glow in the Dark) acrylic panel. Silk screened or direct to substrate printed Dark Blue photoluminescent letters. Text is set in all uppercase letters. Center entire composition horizontally and vertically on sign panel. -Sign to be Photoluminescent per OSSC 1022.8.1.6
FONT:Myriad Pro SemiBold Condensed @ 25% kerning. All capital letters.
R-2 REGULATORY STAIRWELL DETAILSPECIFICATION DETAILSScale: 3”=1’-0”
STAIR 1ROOF ACCESS
11 THROUGH ROOFEXIT THIS LEVEL
FONT:Myriad Pro SemiBold Condensed @ 25% kerning. All capital letters.
Alternate Layout
1 1/2"
1"1 3/4"
5"
1 1/4"
2 3/8"
1"
1 3/4"
Drawing Revised 6/12/19
STAIR 2NO ROOF ACCESS
91 THROUGH 10 DOWN TO 1
TO EXIT
1 1/2"
1"1 3/4"
5"
1 1/4"
2 3/8"
1"
1 3/4"
95
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Regulatory
FONT:Myriad Pro SemiBold Condensed. All capital letters.
R-3 REGULATORY, EXITSPECIFICATION DETAILSScale: 1”=1’-0”
LEVEL V1
★ F L O O R 1
SIGN PLAQUE:1/4” Photoluminescent (Glow in the Dark) acrylic panel. Silk screened or direct to substrate printed Dark Blue photoluminescent tactile letters. Text is set in all uppercase letters. Center entire composition horizontally and vertically on sign panel. Grade 2 Braille characters and background are photoluminescent.
Drawing Revised 6/12/19
LEVEL V1
★ FLOOR 1
8"
2 1/4"
96
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Regulatory
DECORATIVE AND CUSTOM
97
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
DIRECTORY SIGN DECORATIVE, CONSTRUCTION DETAILSScale: 4”=1’-0” on an 11” x 17” sheet
SECTION 1: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
SIDE VIEW: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
TOP VIEW: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
SECTION 2: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
3/16" (th.) lightweight spacer.
APCO FullView sign frame assembly.
1/4" (th.) continuous lightweight backer. Inset 1/4" from all edges.
1/4" (th.) acrylic header, VHB tapedto backer. Edges painted to matchface.
1/4" (th.) painted acrylic panel spaced 1/8" off background.
1/8" (th.) tape spacer.
Mechanically fasten to wall. Fabricator to engineer placement and number of attachment points.
1/2" (th.) painted acrylic accent bars.
Middle accent bars are cutout so that they can be mounted from the front and secured through the backer plate.
Mechanically fasten trim assembly to top and bottom accent bars with tamper resistant countersunk screws. Top and bottom bars to be solid.
Middle accent bar to be routed to fit around trim assembly. Mechanically fasten to backer panel through back of sign.
1/8" (th.) painted acrylic footer, VHB taped to 1/2" (th.) spacer.
1/8" (th.) painted acrylic footer, VHB taped to 1/2" (th.) spacer.
1/2"
3/8" x 3/4" (th.) aluminum bar.
Stylmark 3/4" (w) architectural trim. Part numbers 411331 and 310395 (or equivalent).
1"
3/8"3/8"1"
1 1/8"1 1/2"
98
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
GUIDE SIGN DECORATIVE, CONSTRUCTION DETAILSScale: 4”=1’-0” on an 11” x 17” sheet
SECTION 1: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
SIDE VIEW: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
TOP VIEW: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
SECTION 2: CONSTRUCTION DETAILScale: 4”=1’-0” on an 11” x 17” sheet
Drawing Revised 6/12/19
3/16" (th.) lightweight spacer.
APCO FullView sign frame assembly.
1/4" (th.) continuous lightweight backer. Inset 1/4" from all edges.
1/4" (th.) acrylic header, VHB tapedto backer. Edges painted to matchface.
1/4" (th.) painted acrylic panel spaced 1/8" off background.
1/8" (th.) tape spacer.
Mechanically fasten to wall. Fabricator to engineer placement and number of attachment points.
1/2" (th.) painted acrylic accent bars.
Mechanically fasten trim assembly to top and bottom accent bars with tamper resistant countersunk screws. Top and bottom bars to be solid.
Middle accent bar to be routed to fit around trim assembly. Mechanically fasten to backer panel through back of sign.
1/8" (th.) painted acrylic footer, VHB taped to 1/2" (th.) spacer.
1/2"
3/8" x 3/4" (th.) aluminum bar.
Stylmark 3/4" (w) architectural trim. Part numbers 411331 and 310395 (or equivalent).
1"
3/8"3/8"1"
99
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
EXISTING CABINET
EXISTING CABINET
REPLACEMENT DIRECTORY HEADERPainted acrylic header with silk-screened text and graphics. Fabricator to confirm thinckness of existing header and replace with same size acrylic header.
D-2e MAIN DIRECTORY, WALL MOUNTED, EXISTING CABINETScale: 1”=1’-0” on an 11” x 17” sheet
INSERTSLarge format printed inserts sit behind glass windows. Inserts should fit tight against window for optimal appearance. Fabricator to remove old “slat” system and engineer backing to house inserts. Backing should fit within existing cabinet.
MEASUREMENTSOverall measurements are provided for approximate sizing. It will be the fabricators responsibility to confirm actual dimensions prior to fabrication.
S C H O O L O F N U R S I N G
S C H O O L O F N U R S I N G
APPROX 7'-2"
BUILDING DIRECTORY LISTING FIRST FLOOR BUILDING MAP EXTERIOR CAMPUS MAP
APPROX 6'-9"
APPROX2'-1 5/8"
APPROX2'-1 5/8"
APPROX2'-1 5/8"
Drawing Revised 6/12/19
100
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
D-3 ELEVATOR DIRECTORY DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
Floor 9
HOSPITALELEVATORB
SIDE VIEW SECTION 1
SECTION 2
Floor 9
HOSPITALELEVATORB
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Floor 9
KOHLER OUTPATIENTELEVATOR
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Floor 9
EMERGENCY ELEVATOR
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
Floor 9
HATFIELDELEVATORG
Use these elevators to access thefollowing destinations.
Cafe 9
Care Management 9
Center for Learning/Development 14
Clinical Technology Services 1
CT Scan 8
Diagnostic Radiology 10
EMERGENCY 8
Environmental Services 1
Express Admit Unit 5
Facilities Operations 1
Food & Nutrition 3
Gift Shop 9
Hemodialysis 4
Hospital Administration 8
Information 9
MRI 10
Rehabilitation Services 8
Patient Access Services 9
Patient Advocate 9
Radiology 10
Volunteer Services 9
DESTINATION FLOOR
TOP VIEW
CUSTOM ELEMENTS:HEADER: Custom fabricated cabinet with painted acrylic panels. Acrylic panels are mounted directly to backer plate.
SIDE RAILS: Constructed from extruded aluminum parts and painted.
CABINET:APCO FullView FVS2418(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
BACKER PLATE:1/4” (th.) acrylic panel, inset 1/4” from edges (only behind middle part of sign.
FOOTER: Acrylic panel with silk-screened graphics. Panel surface to be flush with decorative header and cabinet above.
See detail drawing for sections and specifications.
HEADER FONT:Myriad Pro Semibold Condensed @ 25% kerning. Set for Optical kerning. Text is in all capital letters.
FOOTER FONT:Myriad Pro Condensed @ 25% kerning. Set for Optical kerning.
1 3/8"
1 5/8" 1 3/8"2 1/8"
Drawing Revised 6/12/19
1'-6"1'-5 1/2"
1'-8 3/4"3/4"
1/2"
2'-9 1/2"2'-0"
2 1/2"
5"
1 1/2"
1"
2'-11"
101
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
D-4 STRIP MAP w/ GUIDE INFO, DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
D-4a STRIP MAP, DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
DoernbecherChildren’sHospital
Hatf ieldResearch Ctr
KohlerPavilion
Tram
You are in the Hospital Floor 9
SIDE VIEW
SECTION 1
SECTION 2
Cafe
Elevators
Gift Shop
Information
Public Pathways
Restrooms
Hospital CElevators
ToDoernbecherChildren’sHospital
SurgeryWaiting
Patient Relations
ToKohler PavilionTram
YouAreHere
C
Information
You are in the Hospital Floor 9 You are in the Hospital Floor 9You are in the Hospital Floor 9
CUSTOM ELEMENTS:HEADER: Fabricated from painted, layered acrylic panels attached to backer panel with VHB tape.
SIDE RAILS: Constructed from extruded aluminum parts and painted.
FOOTER: Acrylic panel with silk-screened graphics. Panel surface to be flush with decorative header and cabinet above.
See guide detail page for sections and specifications.
SIGN FRAME:APCO FullView FVS2234(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
Similar construction to D-4 SIGN FRAME:APCO FullView FVS2224(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
TOP VIEW
Drawing Revised 6/12/19
2'-10"
2'-0"10"
1/2"
2'-0"
2'-2 1/2"
1'-11 1/2"
1 1/2"
2 3/8"
2'-3 7/8"
1"
3'-1/2"
2'-9 1/2"
102
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
G-1 GUIDE SIGN, LARGE, DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
Floor 9
SIDE VIEW
Floor 9 Floor 9 Floor 9 Floor 9Floor 9
EMERGENCY Elevator
Conference Room 9D53Hatfield ElevatorHospital AdministrationMarquam CaféRestroom
Conference Room 9D53Hatfield ElevatorHospital AdministrationRestroom
Hatfield ElevatorHospital ElevatorTramTo OHSU Hospital
Kohler OutpatientElevator (Access to Parking)
Patient/Family LoungePatient Rm 9020-9144
Kohler InpatientElevatorPatient Rm 9020-9144To OHSU HospitalTram
Hospital Administration
Conference Room 9D53Marquam CaféRestroomTo OHSU Hospital
SECTION 1
SECTION 2
G
TOP VIEW
CUSTOM ELEMENTS:HEADER: Fabricated from painted, layered acrylic panels attached to backer panel with VHB tape.
SIDE RAILS: Constructed from extruded aluminum parts and painted.
FOOTER: Acrylic panel with silk-screened graphics. Panel surface to be flush with decorative header and cabinet above.
See guide detail page for sections and specifications.
SIGN FRAME:APCO FullView FVS2218(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
Drawing Revised 6/12/19
1'-6"
1/2"
2'-3 7/8"
1"
EB
G
103
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
G-1 GUIDE SIGN, LARGE, DECORATIVE, DETAILSPECIFICATION DETAILSScale: 2”=1’-0”
Scale: 1 1/2”=1’-0”
Floor 9
Hospital Administration
Conference Room 9D53Marquam CaféRestroomTo OHSU Hospital
TYPICAL DESTINATION TEXT:Myriad Pro Semibold Condensed, 1” cap @
25% kerning, set for optical display. Some destinations will require 5% or 10%
kerning.
HOSPITAL ADMINISTRATION TEXT:Myriad Pro Semibold Condensed @ 5% kerning,
set for optical display.
CONFERENCE ROOM 9D53 TEXT:Myriad Pro Semibold Condensed @ 10% kerning,
set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
APCO FULLVIEWAPCO FullView FVS2218(H)MF - horizontal configuration (no pin)
Drawing Revised 6/12/19
Floor 9 Floor 9
Floor 9Floor 9
EMERGENCY Elevator
Conference Room 9D53Hatfield ElevatorHospital AdministrationMarquam CaféRestroom
Conference Room 9D53Hatfield ElevatorHospital AdministrationRestroom
Hatfield ElevatorHospital ElevatorTramTo OHSU Hospital
Kohler OutpatientElevator (Access to Parking)
Patient/Family LoungePatient Rm 9020-9144
Kohler InpatientElevatorPatient Rm 9020-9144To OHSU HospitalTram
G
EB
G
1'-8 5/8"
3"
1 1/8" 1 1/2" 1 1/8" 1"
1/8"2 3/8" 1 3/8"
1/2"
1/4"
5/8"
1'-11 1/2"
2'-3 7/8"
1 3/4"
1 1/2"
1 3/4"
1 3/4"
7/8"
1 1/2"1 1/4"
3 1/2"
7/8"
2 1/8"
1 1/2"
2 1/8"
1 3/4"
1"1 7/8"
1 1/2"
1 1/8"
1 1/4"
3 3/8"
1"
3 1/4"
1 3/4"
1"
104
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
G-1a GUIDE SIGN, MEDIUM, DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
G-1b GUIDE SIGN, SMALL, DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
Floor 9Floor 9
Floor 9 Floor 9
Hospital Administration
Conference Room 9D53Marquam CaféRestroomTo OHSU Hospital
SIDE VIEW
TOP VIEW
1'-6"
1/2"
Stairs toEMERGENCY
To OHSU Hospital
TOP VIEW
1'-6"
1/2"
SIDE VIEW
CUSTOM ELEMENTS:HEADER: Fabricated from painted, layered acrylic panels attached to backer panel with VHB tape.
SIDE RAILS: Constructed from extruded aluminum parts and painted.
FOOTER: Acrylic panel with silk-screened graphics. Panel surface to be flush with decorative header and cabinet above.
See guide detail page for sections and specifications.
SIGN FRAME:APCO FullView FVS1818(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
SIGN FRAME:APCO FullView FVS1418(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
Drawing Revised 6/12/19
1" 1"
1'-11 3/4"
1'-7 1/4"
105
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
G-1a GUIDE SIGN, MEDIUM, DECORATIVE DETAILSPECIFICATION DETAILSScale: 2”=1’-0”
G-1b GUIDE SIGN, SMALL, DECORATIVE DETAILSPECIFICATION DETAILSScale: 2”=1’-0”
Floor 9
Hospital Administration
Conference Room 9D53Marquam CaféRestroomTo OHSU Hospital
Floor 9
Stairs toEMERGENCY
To OHSU Hospital
TYPICAL DESTINATION TEXT:Myriad Pro Semibold Condensed, 1” cap @
25% kerning, set for optical display. Some destinations will require 5% or 10%
kerning.
FOOTER TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
SquareFVS
.265"
APCO FULLVIEWAPCO FullView FVS1818(H)MF - horizontal configuration (no pin)
APCO FULLVIEWAPCO FullView FVS1418(H)MF - horizontal configuration (no pin)
Drawing Revised 6/12/19
1'-8 5/8"
3"
1 1/8" 1 1/2" 1 1/8" 1"
1/8"2 3/8" 1 3/8"
1/2"
1/4"
5/8"
1"1 7/8"
1 1/2"
1 1/8"
1 1/4"
3 3/8"
1"
3 1/4"
1 3/4"
1"
2'-1/4"
3 1/4"1 1/2"
1'-7 7/8"
106
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
G-4a GUIDE SIGN, CUSTOM Scale: 1”=1’-0” on an 11” x 17” sheet
G-4b GUIDE SIGN, CUSTOM Scale: 1”=1’-0” on an 11” x 17” sheet
Floor 9
EMERGENCY Elevator
Hatfield Elevator
Hatfield Elevator
Hospital Administration
Marquam Café
Gift Shop
Hospital Elevator
Floor 9
Care Management
Hospital Elevator
Patient Relations
Restroom
Surgery Waiting
To Kohler Pavilion
Tram
Gift Shop
Market
To Doernbecher
To VA Hospital
APPROX 29.875"APPROX 29.5"
Floor 9
EMERGENCY Elevator
Hatfield Elevator
Hatfield Elevator
Hospital Administration
Marquam Café
Gift Shop
Hospital Elevator
APPROX 29.875"
5"
3 1/2" 1 3/4"
3"
1 1/2"
3"
4"
2"
3"
4"
1 3/8"
8 5/8"
CONSTRUCTION:Sign is to replace existing sign inset into the wall. New sign to match dimensions for height, width and depth.Fabricator to verify dimensions and construction prior to fabrication.
FOOTER:Acrylic panel with silk-screened graphics. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
DIVIDER BAR:1/4” (th.) aluminum bar
CABINET:Custom APCO FullView-like vertical rail system. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance.
FOOTER TEXT:Myriad Pro Condensed @ 20% kerning, set for optical display.
TYPICAL DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
Drawing Revised 6/12/19
2 1/2"1/4"
2'-2"
E
G
CE
G
APPROX 86"
APPROX 86.5"
107
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
I-1 PRIMARY ID, DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
I-1a PRIMARY ID, w/SLIDER, DECORATIVEScale: 1”=1’-0” on an 11” x 17” sheet
PhysicalTherapyTerapia física
PHYSIC AL THER APYHEALTH CONNECTIONS
MarquamCaféMonday-Friday6:30 a.m. - 2:00 p.m.
MARQUAM C AFEHEALTH CONNECTIONS
PsychiatryAdministrationMonday-Friday8:00am-4:30pm
PSYCHIATRY ADMINISTR ATIONHEALTH CONNECTIONS
HospitalAdministration
HOSPITAL ADMINISTR ATIONHEALTH CONNECTIONS
Oregon Clinical and TranslationalResearchInstitute (OCTRI)
OR CLINIC AL/TR ANSLATION RSRCH INSTHEALTH CONNECTIONS
9K OrthopaedicSpine
PATIENT ROOMS 9020-9144HEALTH CONNECTIONS
Clinical NeurophysiologyEEG/EMGEvokes PotentialOken CognitiveNeuroscience Lab
CLINIC AL NEUROPHYSIOLOGYHEALTH CONNECTIONS
Patient Rooms9020-9144
OHSU/AFSCMECareer WorkplaceEnhancement Center
C AREER WORKPLACEHEALTH CONNECTIONS
Center for Learning &Development
ConferenceRoom 9D53
CONFERENCE ROOM 9D53HEALTH CONNECTIONS
CONFERENCE ROOM 9D53HEALTH CONNECTIONS
SIDE VIEW
HOSPITAL ADMINISTR ATIONHEALTH CONNECTIONS
TOP VIEW
SIDE VIEW
In Use
TOP VIEW
In Use
IN-USE SLIDER:APCO in-use slider integrated into sign frame assembly. Slider should be the same width of sign cabinet so edges of the bar are flush with the edges of the sign cabinet.
Insert with symbol Insert without symbol
HEADER: Fabricated from painted, layered acrylic panels attached to backer panel with VHB tape.
SIDE RAILS: Constructed from extruded aluminum parts and painted.
FOOTER: Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel surface to be flush with decorative header and cabinet above.
See primary identifier detail page for sections and specifications.
SIGN FRAME:APCO FullView FVS8514(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
HEADER: Fabricated from painted, layered acrylic panels attached to backer panel with VHB tape.
SIDE RAILS: Constructed from extruded aluminum parts and painted.
FOOTER: Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel surface to be flush with decorative header and cabinet above.
See primary identifier detail page for sections and specifications.
SIGN FRAME:APCO FullView FVS8514(H)MF - horizontal configuration, pin to be installed in the upper left position (with no pin), mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique. Cabinet to be surface flush with decorative header above.
Drawing Revised 6/12/19
1"
1'-4 3/4" 1'-2"
1'-2 3/8"
2 1/2"3 3/4"
1'-4 5/8"
1'-2 3/8"
108
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
I-1 PRIMARY ID, DECORATIVE DETAILScale: 2”=1’-0” on an 11” x 17” sheet
I-1a PRIMARY ID, w/SLIDER, DECORATIVE DETAILScale: 2”=1’-0” on an 11” x 17” sheet
PhysicalTherapy
PHYSIC AL THER APYHEALTH CONNECTIONS
MarquamCaféMonday-Friday6:30 a.m. -2:00 p.m.
MARQUAM C AFEHEALTH CONNECTIONS
PsychiatryAdministrationMonday-Friday8 a.m. - 4:30 p.m.
PSYCHIATRY ADMINISTR ATIONHEALTH CONNECTIONS
HospitalAdministration
HOSPITAL ADMINISTR ATIONHEALTH CONNECTIONS
Oregon Clinical and TranslationalResearchInstitute (OCTRI)
OR CLINIC AL/TR ANSLATION RSRCH INSTHEALTH CONNECTIONS
9K OrthopaedicSpine
PATIENT ROOMS 9020-9144HEALTH CONNECTIONS
Clinical NeurophysiologyEEG/EMGEvokes PotentialOken CognitiveNeuroscience Lab
CLINIC AL NEUROPHYSIOLOGYHEALTH CONNECTIONS
Patient Rooms9020-9144
OHSU/AFSCMECareer WorkplaceEnhancement Center
C AREER WORKPLACEHEALTH CONNECTIONS
Center for Learning &Development
PhysicalTherapyTerapia física
PHYSIC AL THER APYHEALTH CONNECTIONS
8 1/2"
2 3/8" 5/8"3/8"
1/4"
3" 1 1/8"2 1/4"
1 5/8"
3 3/4" 3/4"
1 5/8"
1 5/8"
2 1/4"
4 1/2"
1 3/8"
1 1/8"
2 1/4"
1 3/8"
3/4"
1 1/8"
5/8"
5/8"
1"
3/4"
1 3/8"
1 1/8"
4 1/2"
1 3/8"5/8"
2 1/4"5/8"
2 1/2" 2 1/2" 3 3/4"
ConferenceRoom 9D53
CONFERENCE ROOM 9D53HEALTH CONNECTIONS
In Use
3/4"
1 1/4" 3/4"
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
HOURS OF OPERATION TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
HOURS OF OPERATION TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
PATIENT ROOMS TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
PATIENT ROOMS TEXT:Myriad Pro Semibold Condensed @ 25% kerning, set for optical display.
“(OCTRI)” TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
“(Center for...)” TEXT:Myriad Pro Condensed @ 25% kerning, set for optical display.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
Drawing Revised 6/12/19
9"
1'-7/8"
1 1/8"1 1/2"
1'-1 1/2"
1'-2"
1'-4 3/4"
109
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
GeneralDentistryClinic
GENER AL DENTISTRY CLINICSJFGHZSJHGJHG
GeneralDentistryClinic
GENER AL DENTISTRY CLINICCONFERENCE ROOM
In Use In Use
I-1ca PRIMARY ID w/SLIDERScale: 1”=1’-0” on an 11” x 17” sheet
SIDE VIEW
BACKER PLATE:1/8” thick acrylic panel mounted to the wall.
CABINET:APCO FullView Standard Assembly - horizontal configuration, FVS8514(H). Sign frame is mounted to acrylic panel backer plate. Sign is mounted on side for access to release pin. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Sign components are surface flush. Window is removed from frame with a suction cup tool using a lift/pull technique.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters painted white, Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel. Sign components are surface flush.
To matchthicknessof APCO
sign frame
Insert without symbol
approx 1'-2 "
11 3/8"
IN-USE SLIDER:APCO in-use slider integrated into sign frame assembly. Slider should be the same width of sign cabinet so edges of the bar are flush with the edges of the sign cabinet.
Drawing Revised 6/12/19
110
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
Classroom8N124
8N124SJFGHZSJHGJHG
I-1d CLASSROOM/LAB ID w/ INSERTScale: 1”=1’-0” on an 11” x 17” sheet
To matchthicknessof APCO
sign frame
Classroom8N124
8 N124SJFGHZSJHGJHG
SIDE VIEW
approx 1'-2"
approx1'-4"
BACKER PLATE: Constructed from 1/8" (th.) acrylic.
SIGN FRAME:APCO FullView FVS8514(H)MF - horizontal configuration, pin to be installed in the upper left position, mounted to acrylic panel. Large format printed insert sits behind matte acrylic lens. Insert should fit tight against acrylic window for optimal appearance. Window is removed from frame with a suction cup tool using a lift/pull technique.
INSERT FRAME:APCO FullView FVS0414(IA)MF - to allow for 8 1/2” x 11” changeable notice. Frame is mounted to acrylic backer panel. Left side of holder to be filled with painted acrylic panel separated from insert holder by a blocking strip. Notice is changed by inserting a sticky note or similar between the display and non-glare lens then pulling the notice up/out of the frame.
FOOTER:Acrylic panel with tactile and Braille characters. Tactile letters and Braille painted background color. Panel thickness to equal thickness of APCO sign frame. Panel is mounted to backer panel.
Drawing Revised 6/12/19
111
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
Classroom1S008
approx 1'-2"
8 1/2"
2 1/2"
approx9"
4"1/8"
1/2"
1 1/8"
1S0 08SJFGHZSJHGJHG
4"
approx1'-4"
Classroom1S008
1S008SJFGHZSJHGJHG
11"
4"
11"
8 1/2"
112
3
1
2
3
8 1/2” x 11”piece of paper
Edging to align insert and keep from falling behind painted masking
Sub-surfacepainted masking
Folded 8 1/2” x 11”piece of paper
Classroom1S008
1S 0 0 8SJFGHZSJHGJHG
Background painted to match masking when no insert is used
3
I-1d CLASSROOM/LAB ID w/ INSERTSPECIFICATION DETAILSScale: 3”=1’-0”
Scale: 3”=1’-0”
SquareFVS
.265"
DESTINATION TEXT:Myriad Pro Semibold Condensed @ 20% kerning, set for optical display.
PAPER INSERT:Folded standard Xerox paper,
11” width.
EDGING/INSERT EDGE:Edging to align insert and keep from
falling behind painted masking.
SUB-SURFACE PAINTED ACRYLIC LENS:Masks backing and insert edge.
FOOTER TEXT:Myriad Pro Condensed @ 75% kerning, set for optical display. Fabricator to confirm dimensions with ADA Standards for Accessible Design.
5/8"3/8"
1/4"
2 1/2"
4 1/8"1 5/8"
Drawing Revised 6/12/19
112
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
LOGO ON A LIGHT BACKGROUND:1/4" (th.) aluminum logo painted to match Dark Grey.
LOGO ON A DARK BACKGROUND:1/4" (th.) brushed aluminum (horizontal grain) logo.
MOUNTING:Pin-mount 1/4" from wall surface with studs welded to reverse side of logo elements. Secure with silicone adhesive or other per code.
Side View(detail)
I-8 LOGOScale: 1"=1'-0" on an 11" x 17" sheet
2'-11"
5'-0"
2'-0"
NOTE:Use of this sign type must be approved by the Chief Marketing Officer.
Drawing Revised 6/12/19
113
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
Check-in Building 2Ctr for Health & Healing - Bldg 1Pharmacy Building 2Tram
4'-6"
Check-in Building 2Parking ElevatorRestroomsRood Family Pavilion Garage
Check-in Building 2Ctr for Health & Healing - Bldg 1Pharmacy Building 2Tram
6 3/8"
2 1/2"4 3/8"
2 3/8"3"
P6
O-5c OVERHEAD GUIDE, DOUBLE-SIDED, PROJECTION MOUNTEDScale: 1”=1’-0” on an 11” x 17” sheet
O-5c OVERHEAD GUIDE, DOUBLE-SIDED, PROJECTION MOUNTED
SIGN:Message panels are fabricated from 1/2" (th.) painted Komacel panels with APCO aluminum mounting bracket with square profile. Sign edges to be painted to match face. Messaging to be surface applied vinyl graphics. Sign bottom edge to have break-formed aluminum trim fabricated from .090 (th.) aluminum.
FONT:Myriad Pro SemiBold Condensed @ 25% kerning.
NOTE:An ampersand is acceptable in Center for Health & Healing because it’s part of the offical name.
3 5/8"
Drawing Revised 6/12/19
SIDE A SIDE B
2'-8"
1'-8"
Suspended overheads use Carl Stahl I-Sys® Edelstahl-Seilsystem Stainless Steel Wire Rope System. Fork with internal thread (#817-0500) and threaded M5 cable for mounting.
1" x 1/2" aluminum U channel painted to match Metallic Silver
114
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
N-1d-alt NOTICE HOLDER, LETTER PORTRAIT, ACRYLICScale: 3”=1’-0” on an 11” x 17” sheet
Front ViewSide View
Insert Layout TBD
1/4" (th.) black wall spacer made from inexpensive recycled or recyclable material (Komacel or Sintra) to “float” sign off the wall. Inset from all sign edges 3/8".
All edges eased so there are no sharp corners or edges.
1/4" (th.) clear acrylic backer panel.
Attach to wall with VHB tape and liquid adhesive as required.
1/8" (th.) non-glare acrylic lens. Attached to backer panel with VHB tape, leaving left edge open to allow insertion of printed insert.
Leave slot between acrylic lens and backer panel to allow insertion of printed insert. Insert to be tightly sandwiched between acrylic backer and non-glare acrylic lens – no rippling.
3/8" 3/8"
3/8"
1/2"
11 1/2"
9"
8 1/2" x 11" laminated printed sign insert to be minimally printed at 1200 DPI using pigment-based UV inks on a white, satin finish photo paper, with a matte UV over-laminate. The thickness of the insert must be heavy enough so that no wrinkles or waves will occur once installed into the sign.
Layouts can be customized depending on needs of the facility. Inserts can be pre-printed or customized using a simple word processing template. If a template is created it should use the system fonts in the Myriad Pro family whenever possible. If necessary a sans serif typeface like Arial can be used so that it looks compatible with the system. White paper can be used but avoid using colors that do not match the system.
Non-glare acrylic lens has a sub-surface painted border on the acrylic lens to match Light Silver. Border to conceal insert edges and VHB tape.
Provide thumb slot on backer behind acrylic lens for easy insert removal.
Drawing Revised 6/12/19
115
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom
N-1h NOTICE HOLDER W/BROCHURE HOLDERSScale: 3”=1’-0” on an 11” x 17” sheet
SIGN FRAME:APCO FullView FVS8511(H) sign. Custom-printed 11" x 8 1/2" insert sits behind matte acrylic lens.
SIGN BACKER:1/4" (th.) sign backer to extend below sign frame. Paint to match Silver.
BROCHURE HOLDERS:Mount two brochure holders to sign backer below sign frame. Suggested brochure holder: Slim Pocket Brochure Holder - for Wall Mounted 3-3/4 wide Trifold Literature - See more at: http://www.display-world.com.
11"
10"
9"
Drawing Revised 6/12/19
116
STANDARDS MANUAL FOR INTERIOR WAYFINDING SIGNAGE Manual Revised 6/12/19
Decorative and Custom