Standard ProductsWater Treatment 20-09-13
-
Upload
americanguy10 -
Category
Documents
-
view
218 -
download
1
description
Transcript of Standard ProductsWater Treatment 20-09-13
Standard ProductsWater Treatment
Standard ProductsWater Treatment
S T A N D A R D P R O D U C T S
Veolia Water Solutions & Technologies (VWS), subsidiary of Veolia
Water, is a specialised provider of technological solutions in water
treatment.
All standard products offered by VWS are manufactured to strict
quality standards, using the best materials.
Standard products have short lead times and can be quickly
installed on site. Many are modular in design and as such are easily
integrated into existing plant.
VWS manufacturing units can provide engineered systems to meet
specific needs. Standard products may also be configured for higher
flow rates, water qualities, etc.
All technologies are supplied and supported by local VWS subsidiaries.
Veolia Water Solutions & Technologies is continually extending and
enriching its offer in order to respond to the changing needs of its
clients.
Related Services, Consumables & Spare Parts: Local after-sales service
and support teams offer preventative and corrective maintenance
programs to ensure the long-term, efficient operation of installed
plant.
Screen & Disc Filtration
Screen and disc fi lters are used to remove particulate impurities from water.
Particles in water can cause problems of erosion in pumps and pipe work and can
block fi ne jets such as spray nozzles. Water fl ows through a screen or between
discs which retain particles larger than the defi ned fi ltration grade. Screen and disc
fi lters do a similar job to cartridge fi lters but the screens/discs are cleaned rather
than replaced, so operating costs are minimal.
Typical applications include:
Protection of domestic water fi ttings
Protection of membrane processes from fouling
Filtration of cooling water to prevent heat exchanger fouling
Pre-fi ltration of process water
Scre
en &
Dis
cFi
ltra
tio
n
Berkal™Protective Filters
Berkal™ disc filtration systems remove contaminants such as fibres, grit, sand and algae.
Flow rates from 10 to 120 m3/hr.
Features & Benefits
• Compact systems with high flowand retention capacities
• Automatic backwashing of indivi-dual filters based on time or pres-sure differential; continual flow,optimised backwash water usage
• Modular design, choice of filtrationgrades from 20 to 400 µm; highlyscalable, flexible
• Combines screen filtration anddepth filtration to ensure highcontaminant removal rates
• Air assisted backwashing; rinsewater consumption is only 0.5% offiltrate capacity
• No consumables; low runningcosts, minimal maintenance
• Corrosion resistant polypropylenepipework
Options• Filtration grades (µm): 20, 50, 100,
130, 200, 400• Backwashing: air aided flushing
(standard), internal or external flushing • Piping: plastic coated steel,
stainless steel
Applications
• Side stream filtration of coolingtower water
• Pre-treatment to softeners, ion exchangers or membrane systems
• Feed water for irrigation systems
• Prevention of corrosion andblockages within pipework, valves,distributors and other equipment
• Municipal wastewater
• Aquaculture
Related Services
Local after-sales service and supportteams offer preventative and corrective maintenance programs to ensure the long-term, efficientoperation of installed plant.
Berkal™System Performance
Temperature and Pressure Ratings
Model
Temp. Range Pressure
Flow Connections BackwashAir**
Width Height DepthRates*
2/1/100
2/2/100(S)
2/3/100(S)
2/4/100(S)
2/5/100(S)
2/6/100(S)
2/7/100(S)
2/8/100(S)
m3/hr
10-15
15-30
30-45
45-60
60-75
75-90
90-105
105-120
litres
46
46
46
46
46
46
46
46
°C
5-35
5-45
5-55
5-65
5-70
bar
0.8-10
0.8-9
0.8-8
0.8-7
0.8-6.5
mm
821
955
1297
1597
1897
2155
2455
2755
mm
834
1101
1101
1129
1129
1129
1156
1156
mm
408
825
825
852
852
848
907
907
Raw
Rp 2"
DN80
DN80
DN100
DN100
DN100
DN150
DN150
Filtrate
Rp 2"
DN80
DN80
DN100
DN100
DN100
DN150
DN150
Backwash
Rp 2"
DN50
DN50
DN50
DN50
DN50
DN50
DN50
*100µm filter**per filter element at 5-6 bar(S) S version is with high-grade steel pipe work
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkal™/AQF0021_EN_V1.2
3.8 ¾
4.2 1
4.3 1 ¼
3.8 ¾
4.2 1
1 ¼4/3
190
190
190
190
190
190
423
413
413
463
463
463
190
190
190
190
190
190
30
30
30
30
30
30
Berko 2
104
136
270
297
297108
1 130 270
135
135
135
1352.3
Berko 3 5.0 1 ¼
Berko 4 8.0 1 ½
Berko 5 20.9
0116823620361 ¾ R ¾ R5.401168254203611 R1 R0.60116823620361 ¼ 1 R ¼ 1 R0.90116825720361 ½ 1 R ½ 1 R0.9
979797
120120
9448710761 ¾ R ¾ R3.435490207611 R1 R2.73542220761 ¼ 1 R ¼ 1 R8.72356420761 ½ 1 R ½ 1 R0.0123576207612 R2 R5.11
1422354575
100
Rp 1½Rp 2
DN 65DN 80
DN 100DN 125
Rp 1½Rp 2
DN 65DN 80
DN 100DN 125
R ½R ½R 1R 1R ¼R ¼
101010101010
959595959595
285285370370480480
475475493510600620
1422354575
100
Rp 1½Rp 2
DN 65DN 80
DN 100DN 125
Rp 1½Rp 2
DN 65DN 80
DN 100DN 125
R ½R ½R 1R 1R ¼R ¼
101010101010
959595959595
285285370370480480
530530660665720730
354575
100
DN 65DN 80
DN 100DN 125
DN 65DN 80
DN 100DN 125
R 1R 1R ¼R ¼
10101010
95959595
370370480480
660665720730
Granular Media Pressure Filtration
Granular media is contained within a pressure vessel, typically GRP or coated steel. Water enters the top of the vessel and fl fo deb eht hguorht sdrawnwod swo media, exiting through a collector system at the base. Contaminants are removed by straining and/or adsorption depending on the chosen media. The fi lters must be periodically backwashed.
Depending on the type of fi lter media used, granular media fi ltration has a variety of applications including:
Filtration of water after chemical dosing to remove colloidal haze and turbidity Pre-fi ltration to protect membrane processes from fouling Filtration of cooling water to prevent heat exchanger fouling Filtration of borehole water to remove iron and manganese Removal of chlorine from water to protect ion exchange resins or membranes Increasing the pH of acidic water to prevent corrosion Feed water for drip irrigation systems
Sand is used to remove particulates and suspended solids. For high suspended solids loads, a layer of coarse anthracite may be added above the sand. Multimedia fi ltration may also be used for very fi ne fi ltration by adding a layer of fi ne garnet below the sand. Sometimes two stages of fi ltration are used –often anthracite and sand in the fi rst vessel with sand and garnet in the second. This allows chemicals like polyelectrolytes to be added between the stages to improve fi ltration effi ciency.
Granular activated carbon is widely used to remove chlorine from water prior to ion exchange or reverse osmosis where it could damage the resins or membranes.Dechlorination by activated carbon also removes the taste associated with chlorine.Activated carbon is also used to remove a wide range of organic chemicals including chlorinated hydrocarbons, pesticides and the species that cause taste, odour and co-lour.
Manganese dioxide is used as a catalytic fi lter bed to remove iron and manganese from borehole water for a range of industrial applications.
Dolomite or limestone chips are occasionally used in fi a sa ro enola rehtie ,sretl separate layer above sand, to neutralise low pH waters. The media slowly dissolves and has to be replaced at regular intervals.
Gra
nula
r Med
iaPr
essu
reFi
ltrat
ion
m3 5.22157.0rh/
Inches
mm 620 620 620 620
mm 968 1439 1705 1748
mm 480 480 530 550
kg 55 75 150 200
bar 1.4 - 8.5
bar 10 10 10 10
°C
Rp 1
40 40 40 40
Rp 1 Rp 1 Rp 1
1.4 - 8.5 1.4 - 8.5 1.4 - 8.5
1 ½2 ½2 ½
1 1 ½1 ½2 ½2 ½
800 650 1914 70 522 1666900 750 2140 90 595 1892
1050 900 2140 135 746 18921200 1150 2140 190 896 18921550 1400 2302 320 1250 2005
2 ½
2 ½
2 ½
1900 1450 23002250 1700 2410 2500 2000 26702800 2300 27203000 2450 29203300 2700 30603900 3200 3320
1900 1450 33002250 1700 34102500 2000 36702800 2300 37203000 2450 39203300 2700 40603900 3200 4320
½½ ½½ ½½ ½
½ ½
800 650 1914900 750 2140
1050 900 21401300 1150 21401550 1400 2302
1900 1450 23002250 1700 24102500 2000 26702800 2300 27203000 2450 28903300 2700 30603900 3200 3320
Softening
Salts of calcium and magnesium have low solubility. In water they are collectively called “hardness” and cause a variety of problems in industrial water use, including:
Scale in cooling towers, causing blockages Scale in low pressure steam boilers, reducing heat transfer effi ciency Fouling in reverse osmosis systems, causing loss of performance Scale in hot water calorifi ers (heaters), reducing heat transfer effi ciency Scum in laundries, reducing effi ciency of detergents Deposits in domestic hot and cold water services, contributing to Legionella
problems Streaky deposits in glass and bottle washing
Ion exchange softening is the most widely used softening process. Water is passedthrough a bed of cation exchange resin where calcium and magnesium ions are removed from the water in exchange for sodium ions. When the sodium ions on the resin have been replaced by calcium or magnesium ions, the softening reaction stops and the resin need to be regenerated. Regeneration is achieved by passing a salt solution through the resin bed.
Softening
Soft
enin
g
Berkoion™ SoftenersCompact Range
Berkoion™ Compact softeners provide high quality softened water for industrial and domestic applications.
Flow rates from 1.0 to 2.3 m3/hr.
Features & Benefits:
• Compact designs with integrated brine tanks; space saving, easy installation
• Simplex configuration
• Volume or time based automatic regeneration; minimal operator involvement
• Optimised hydraulic conditions; reduce salt usage, low cost per litre of treated water
A-Series
• Automatically regenerated after 4 days without use; bacterial control, avoids resin problems
• Complete disinfection during regeneration; bacterial control
• Electronic display; simple monitoring and operation
Applications
• Boiler feed
• RO feed water
• General manufacturing
• Glass washing
• Cleaning and rinse waters
• Dishwashing
• Domestic
Related Services
Local after-sales service and support teams offer preventative and corrective maintenance programs to ensure the long-term, efficient operation of installed plant.
Visit our website:www.veoliawaterst.com
Model Flow Rates*
Capacity Salt UsagePer Regen.
Connection WorkingPressures
Width Height Depth
m3/hr kg CaCO3 kg inches bar mm mm mm
Z Series
Simplex, time controlled
Z15 KV 1.0 - 1.2 1.1 3.75 R 1 1.4 - 8.5 570 1090 435
A Series
Simplex, volume controlled
A4 KV 1.9 - 2.1 0.18 0.36 Rp 1 1.4 - 8.0 500 665 320
A13 KV 2.0 - 2.3 0.64 1.17 Rp 1 1.4 - 8.0 590 1090 280
*A Series - With pressure loss of 0.8 bar and mixing from 20 to 8°dH (358 to 143 ppm CaCO3)Z15 KV - With pressure loss of 0.32 bar at 1.2 m3/h
System Performance
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion™ Compact Range/AQF0013_EN_V2.0-Nov.13
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Material Specifications
Potable water free from organic contamination and suspended matter. Maximum temperature 30°C (40°C for Z15 KV).
Feed Water Requirements
All models 230V 50Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Electrical Supply
Berkoion™ Softeners
Berkoion™ SoftenersClassic Duplex Range
Berkoion™ Classic Duplexsofteners provide high qualitysoftened water for industrialapplications.
Flow rates from 1.4 to 17 m3/hr.
Features & Benefits:
• Proven designs and materials; efficient operation, easy to maintain, reliable
• Volume controlled automatic regeneration; minimal operator involvement, efficient operation
• Bercore™ counter current regeneration; reduces salt usage and waste, lowers cost per litre of treated water, improves treated water quality
• Duplex design; continual flow of treated water
Specific models
• Advanced controller with LCD display; range of control options, easy to use, integrates with centralized control systems
Applications
• Boiler feed
• Glass washing
• Cleaning and rinse waters
• RO feed water
• General manufacturing
Related Services
Local after-sales service and support teams offer preventative and corrective maintenance programs to ensure the long-term, efficient operation of installed plant.
Visit our website:www.veoliawaterst.com
Model Flow Rates Capacity Salt UsagePer Regen.
Connection WorkingPressures
Width Height Depth
m3/hr kg CaCO3 kg Rp (inches)/DN(mm) bar mm mm mm
Volume controlled
AWA 2-25 1.4 - 2.0 1.3 2.5 Rp 1 1.8 - 8.5 1110 1087 390
AWA 2-45 2.3 - 3.2 2.3 4.0 Rp 1 2.0 - 8.5 1310 1577 530
AWA 2-70 2.8 - 3.5 3.5 6.5 Rp 1 2.0 - 8.5 1447 1556 530
AWA 2-90 4.0 - 5.0 4.5 8.0 Rp 1 2.0 - 8.5 1579 1832 600
AW 2-105 6.0 - 7.2 4.8 8.6 DN 40 2.0 - 8.5 1748 1918 650
AW 2-150 8.0 - 10.0 7.1 12.6 DN 40 2.5 - 8.5 2190 1928 980
AW 2-250 12.0 - 14.0 12.2 21.6 DN 50 2.5 - 8.5 2482 1895 995
AW 2-350 15.0 - 17.0 17.3 30.6 DN 50 2.5 - 8.5 2853 2228 1185
Displays & ControllersAW 2-25, AW 2-45, AW 2-70, AW 2-90Microprocessor controller with LED display.AW105, AW150, AW250, AW350Advanced microprocessor controller with LCD display. Intuitive symbol based keypad; programmable with retentive memory; indication of current flow rate, capacity remaining before next regeneration; pulse input. May be connected to centralized control system.
System Performance
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion™ Classic Duplex Range/AQF0040_EN_V3.0-Nov.13
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Material Specifications
Potable water free from organic contamination and suspended matter. Maximum temperature 40°C.
Feed Water Requirements
All models 230V 50Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Electrical Supply
Berkoion™ Softeners
Berkoion™ SoftenersHigh Flow Duplex Range
Berkoion™ High Flow Duplexsofteners provide high qualitysoftened water for industrialapplications.
Flow rates from 2.7 to 68 m3/hr.
Features & Benefits:
• Proven designs and materials; efficient operation, easy to maintain, reliable
• Volume controlled automatic regeneration; minimal operator involvement, efficient operation
• Bercore™ counter current regeneration; reduces salt usage and waste, lowers cost per litre of treated water, improves treated water quality
• Duplex design; continual flow of treated water
• Multiple individual valves; reduce pressure loss by almost 50% compared to single valve systems
• Advanced controller with LCD display; range of control options, intuitive operation, integrates with centralized control systems
Applications
• Boiler feed
• Glass washing
• Cleaning and rinse waters
• RO feed water
• General manufacturing
Related Services
Local after-sales service and support teams offer preventative and corrective maintenance programs to ensure the long-term, efficient operation of installed plant.
Visit our website:www.veoliawaterst.com
Model Flow Rates Capacity Salt UsagePer Regen.
Connection WorkingPressures
Width Height Depth
m3/hr kg CaCO3 kg mm bar mm mm mm
Volume controlled
AW 2-550 2.7 - 27.0 28.0 49.5 DN 80/80 3.0 - 8.5 3195 2650 1390
AW 2-800 3.9 - 39.0 40.7 72.0 DN 100/80 3.0 - 8.5 3945 2735 1695
AW 2-1050 5.1 - 51.0 53.4 94.5 DN 100/80 3.0 - 8.5 4490 2815 1770
AW 2-1400 6.8 - 68.0 71.2 126.0 DN 100/100 3.0 - 8.5 4665 2910 1925
Displays & ControllersAW SeriesAdvanced microprocessor controller with LCD display. Intuitive symbol based keypad; programmable with retentive memory; indication of current flow rate, capacity remaining before next regeneration; pulse input. May be connected to centralized control system.
*All models require a source of compressed air
System Performance
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion™ High Flow Duplex Range/AQF0043_EN_V2.0-Nov.13
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Pipework Polyvinyl Chloride (PVC)
Material Specifications
Potable water free from organic contamination and suspended matter. Maximum temperature 40°C.
Feed Water Requirements
All models 230V 50Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Electrical Supply
Berkoion™ Softeners
Reverse Osmosis
Reverse osmosis (RO) is a process that uses a membrane to remove over 95% of dissolved salts, such as calcium bicarbonate and sodium chloride, from water. It is used either alone or in combination with processes such as ion exchange in a variety of industrial applications where the total dissolved solids (TDS) concentration in water has to be reduced, including:
Purifi ed water for pharmaceutical manufacturing Laboratory glassware washing Semiconductor rinse water Process water Water for soft drinks production and brewing Boiler feed water Desalination of brackish or sea water to drinking water quality Recycling and reuse
The RO membrane also acts as a very fi ne fi lter removing 99% of suspended and colloidal solids, bacteria and organic molecules with molecular weights in excess of about 200Da. This makes the process particularly attractive for applications where treated water not only has to be low in TDS but also of high clarity and free from bacteria, such as that used for soft drinks and pharmaceuticals manufacturing.
Reverse Osmmossis
Reve
rse
Osm
osis
SIRION MiniTM
Reverse Osmosis Systems
SIRION MiniTM reverse osmosis systems produce high puritywater, removing up to 98% of dissolved inorganics and over99% of large dissolved organics,colloids and particles.
Flow rates from 10 to 90 l/hr.
Features & Benefits
Low energy membranes result inlower operating pressures; cost savings
Optimized flow:size ratio; space saving and efficient
5µm pre-filtration included withinunit; membrane protection
Digital user interface; simple operation, monitoring of conductivity and temperature
Dry run monitor; pump protection
Treated water diverted at start-up;ensures water quality
Timed recirculation rinse; reducesmembrane fouling
Option
Output to PLC via analogue signalfor conductivity monitoring
Applications
Micro Electronics
Boiler feed
Hospitals
Food and beverage industry
Automotive industry
Laboratory
Industrial process water
Related Services
Local after-sales service and supportteams offer preventative and corrective maintenance programs to ensure the long-term, efficientoperation of installed plant.
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Mini/AQF0010_EN_V3.0
SIRION MiniTM
System Performance Model 10-15 EP 10-40 EP 10-80 EP
Nominal Flows at 12°C*Permeate 09-0654-0302-01rh/l
Feed 0710904rh/l
Typical Salt Rejection 89-6989-6989-69%
Pump Motor Size 52.052.052.0Wk
*Flow rates are dependent on feed water quality, those quoted are typical values based on 1000 ppm TDS & SDI <3.
System Dimensions Model 10-15 EP 10-40 EP 10-80 EP
Height 796796796mm
Depth 083083083mm
Width 054054054mmWeight 360653gk
Pipe ConnectionsModel
Feed Water (BSPP Male) 1/2''
mm 8mm 8mm 8
mm 8mm 8mm 8
''2/1''2/1
Permeate (push in)Concentrate (push in)
Feed Water Supply QualityPotable water free from organic contamination, chlorine and suspended matter. Softening may be required for hard water areas.
Supply Pressure rab 6.xamrab 2.nimTemperature C°52.xamC°2.nim
Electrical SupplyAll models 230V 50Hz standard.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
10-15 EP 10-40 EP 10-80 EP
SIRION™ MidiReverse Osmosis Systems
SIRION™ Midi reverse osmosissystems produce high puritywater, removing up to 98% of dissolved inorganics and over99% of large dissolved organics,colloids and particles.
Flow rates from 90 to 800 l/hr.
Features & Benefits
Low energy membranes result in lower operating pressures; cost savings
Optimised flow:size ratio; space saving and efficient
1µm pre-filtration included withinthe unit; membrane protection
Programmable user interface; simple operation, monitoring andstorage (14 days) of flow rate,conductivity and temperature values
Modem & RS232 connections
Dry run monitor; pump protection
Treated water diverted at start-up;ensures water quality
Timed recirculation rinse; reducesmembrane fouling
Option
Output to PLC via analogue signalfor conductivity monitoring
Applications
Boiler feed
Industrial process water
Cleaning and rinse waters
Healthcare
Pharmaceuticals
Laboratory
Reuse/recycling
Related Services
Local after-sales service and support teams offer preventativeand corrective maintenance programs to ensure the long-term,efficient operation of installed plant.
Hydrex® Chemicals
Hydrex® 4000 water treatment chemicals from Veolia Water Solutions & Technologies should be used for optimized operation.
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Midi/AQF0009_EN_V3.1 - Dec.13
SIRION™ MidiSystem Performance
ModelNominal Flows at 12°C*PermeateFeedTypical Salt RejectionPump Motor Size
*Flow rates are dependent on feed water quality, those quoted are typical values based on 1000 ppm TDS & SDI <3.
System Dimensions ModelHeight mmDepth mm
mmkg
WidthWeight
Feed Water Supply QualityPotable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply PressureTemperature
Electrical Supply10-100EP to 10-300EP models 230V, 1ph, 50 Hz standard10-500EP & 10-750 EP models 400V, 3ph–N–PE, 50 Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Pipe ConnectionsModel
Feed Water (push in)Permeate (push in)First Permeate (push in)
Concentrate (push in)
101062060059
10-100 EP
12 mm
12 mm12 mm12 mm
10-100 EP
90-110150
96-980.56
10-100 EP
l/hrl/hr%
kW
126062060061
10-200 EP
12 mm
12 mm12 mm12 mm
10-200 EP
10-200 EP
180-220300
96-980.56
126062060068
10-300 EP
12 mm
12 mm12 mm12 mm
10-300 EP
10-300 EP
280-330450
96-980.56
126062060073
10-500 EP
15 mm
15 mm15 mm12 mm
10-500 EP
10-500 EP
450-550750
96-981.5
126062060095
10-750 EP
15 mm
15 mm15 mm12 mm
10-750 EP
10-750 EP
650-800100096-98
1.5
rab 6.xamC°52.xam
rab 2.nimC°2.nim
SIRION™ MaxiReverse Osmosis Systems
SIRION™ Maxi reverse osmosissystems produce high puritywater, removing up to 98% of dissolved inorganics and over99% of large dissolved organics,colloids and particles.
Flow rates from 450 to 5000 l/hr.
Features & Benefits
• Low energy membranes result in lower operating pressures; cost savings
• Optimised flow:size ratio; space saving and efficient
• 1µm pre-filtration included withinthe unit; membrane protection
• Programmable user interface; simple operation, monitoring andstorage (14 days) of flow rate,conductivity and temperature values
• Modem & RS232 connections
• Dry run monitor; pump protection
• Treated water diverted at start-up;ensures water quality
• Timed recirculation rinse; reducesmembrane fouling
Option
• Output to PLC via analogue signalfor conductivity monitoring
Applications
• Boiler feed• Industrial process water
• Cleaning and rinse waters
• Reuse/recycling
• Healthcare
• Pharmaceuticals
Related Services
Local after-sales service and supportteams offer preventative and corrective maintenance programs to ensure the long-term, efficientoperation of installed plant.
Hydrex® Chemicals
Hydrex® 4000 water treatment chemicals from Veolia Water Solutions & Technologies should be used for optimised operation.
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Maxi/AQF0007_EN_V3.1 - Dec.13
System Performance Model 14-500-EP 14-750-EP 14-1000-EP 14-1500-EP 14-2000-EP 14-2500-EP 14-3000-EP 14-4000-EP 14-5000-EPNominal Flows at 12°C*PermeateFeedTypical Salt Rejection %Pump Motor Size
*Flow rates are dependent on feed water quality, those quoted are typical values based on 1000 ppm TDS & SDI <3.
System Dimensions Model 14-500-EP 14-750-EP 14-1000-EP 14-1500-EP 14-2000-EP 14-2500-EP 14-3000-EP 14-4000-EP* 14-5000-EP*
HeightDepth mmWidth mmWeight kg
*If height is an issue consider the SIRION™ Mega
Feed Water Supply QualityPotable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure rab 6.xamrab 2.nimTemperature C°52.xamC°2.nim
Electrical SupplyAll models 380/415V, 3 phase, 50Hz standard.
All connections are union socket - PVC-U
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Pipe ConnectionsModel 14-500-EP
Feed DN 20
DN 15DN 15
DN 15
14-750-EP
DN 20
DN 15DN 15
DN 15
14-1000-EP
DN 20
DN 15DN 15
DN 15
14-1500-EP
DN 25
DN 15DN 25
DN 25
DN 25
DN 15DN 25
DN 25
14-2000-EP 14-2500-EP
DN 32
DN 25DN 25
DN 25
DN 32
DN 25DN 25
DN 25
14-3000-EP 14-4000-EP
DN 40
DN 25DN 32
DN 32
14-5000-EP
DN 40
DN 25DN 32
DN 32
PermeateFirst Permeate
Concentrate
23581070636290
16301070636240
2358
3306361070
2358
3706361145
2358
4106361070
2950
3008001200
2950
32580012001070
636220
1630
1070636200
1630mm
l/hrl/hr
kW
96-98
450-500700
2.2
96-98
650-8001000
2.2
96-98
950-11001400
2.2
96-98
1450-16002000
4.0
96-98
1950-21002700
4.0
96-98
2450-26003300
4.0
96-98
2900-31004000
4.0
96-98
3800-40005200
4.0
96-98
4700-50006250
5.5
SIRION™ Maxi
SIRION™ MegaReverse Osmosis Systems
SIRION™ Mega reverse osmosissystems produce high puritywater, removing up to 98% of dissolved inorganics and over99% of large dissolved organics,colloids and particles.
Flow rates from 5 to 30 m3/hr.
Features & Benefits
Low energy membranes result in
Frequency controlled variable speedpump can save up to 50% of theelectrical power required byconventional systems
lower operating pressures; cost savings
5µm pre-filtration included withinthe unit for membrane protection
Programmable user interface; simple operation, monitoring andstorage (14 days) of pressure, flowrate, conductivity and temperaturevalues
Modem & RS232 connections
Dry run monitor; pump protection
Treated water diverted at start-up;ensures water quality
Timed recirculation rinse; reducesmembrane fouling
Options
Anti-scalant/sodium bisulfate dosing equipment
Output to PLC via analogue signal
pH control
Concentrate rinse valve
for conductivity monitoring
Applications
Boiler feedIndustrial process waterCooling waterReuse / recyclingHealthcareBiotechnologiesElectronicsHospitalsChemical industryPrimary metals
Related Services
Local after-sales service and supportteams offer preventative and corrective maintenance programs to ensure the long-term, efficientoperation of installed plant.
Hydrex® Chemicals
Hydrex® 4000 water treatment chemicals from Veolia Water Solutions & Technologies should be used for optimised operation.
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Mega/AQF008_EN_V4.1 - Dec.13
SIRION™ Mega
Feed Water Supply QualityPotable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure rab6.xamrab2.nimTemperature C°03.xamC°2.nim
Electrical SupplyAll models 380/415V, 3 phase, 50Hz standard.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
System Performance ModelNominal Flows at 10°C*PermeateFeedTypical Salt RejectionPump Motor Size
*Flow rates are dependent on feed water quality and temperature, the above values are based on 1000 ppm TDS, 10°C & SDI <3.
System Dimensions Model
HeightDepthWidthWeight (dry)
*If height is not an issue consider the more compact SIRION™ Maxi
All connections are union socket - PVC-U
Pipe ConnectionsModel
FeedPermeateConcentrate
m3/hrm3/hr
kW%
mmmmmmkg
110 x 2
56.3
96-987.5
17509004100980
110 x 2*
110 x 2DN 40DN 40DN 40
110 x 3
7.59.4
96-9811
185090041001100
110 x 3
110 x 3DN 40DN 40DN 40
110 x 4
1012.5
96-9811
1850900
49001150
110 x 4
110 x 4DN 50DN 40DN 40
210 x 4
1518.8
96-9815
1850900
49001200
210 x 4
210 x 4DN 50DN 50DN 40
211 x 4
2025
96-9818.5
2150900
49001350
211 x 4
211 x 4DN 65DN 50DN 40
211 x 5
2531.3
96-9822
2255900
59001700
211 x 5
211 x 5DN 65DN 65DN 40
3037.5
96-9830
320 x 5
2280900
59001700
320 x 5
320 x 5DN 80DN 65DN 50
SIRION MultipureTM
Reverse Osmosis Systems
SIRION MultipureTM reverse osmosis systems are specifically designedto treat brackish waters. They reject over 99% of the salt contained within the feed water.
Flow rates for standard systemsrange from 4.7 to 104.2 m3/hr forfeed waters of up to 5 000 ppm(TDS.)
Features & Benefits
• Standardized and skid-mounted;short lead times and quick start-up
• Small footprint; easily integratedinto existing plant
• Chemical pre-treatment; protectsthe RO membranes
• High pressure pump with variablefrequency drive; efficient and quietoperation
• State-of-the-art RO membranes
• Flushing and chemical cleaning system; removes salt deposits, prevents scaling and maintains system performance
• Touch screen interface for easy operation
• PLC control
Applications
• Production of potable water
• Industrial process water
• Agricultural irrigation
• Industrial water reuse
Related Services
Local after-sales service and supportteams offer preventative and corrective maintenance programs to ensure the long-term, efficientoperation of installed plant.
Hydrex® Chemicals
Hydrex® 4000 water treatment chemicals from Veolia Water Solutions & Technologies should beused for optimized plant operation.
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Multipure/AQF0016_EN_V2.0
SIRION MultipureTM
Equipment Performance & Dimensions pmuPsenarbmeMsnoisnemiD lanimoNC°51 @ wolF
Model Feed Permeate Recovery WxDxH Weight 1st array 2nd array Powerm3/hr m3/hr % m kg Quantity Quantity kW
Feed water TDS up to 1000 ppmRO 100/1 5.94 4.17 70RO 150/1 8.92 6.25 70RO 225/1 14.29 9.38 70RO 325/1 19.10 13.54 70RO 425/1 23.39 17.71 75RO 500/1 27.67 20.83 75RO 600/1 32.94 25 75RO 750/1 41.34 31.25 75RO 850/1 47.41 35.42 75RO 1100/1 61.19 45.83 75RO 1300/1 72.13 54.17 75RO 1450/1 80.66 60.42 75RO 1800/1 100.13 75 75RO 1900/1 105.7 79.17 75RO 2100/1 116.82 87.5 75RO 2200/1 122.39 91.67 75RO 2500/1 139.07 104.17 75Feed water TDS up to 3000 ppmRO 100/3 6.41 4.17 70RO 125/3 7.38 5.21 70RO 200/3 12.78 8.33 70RO 280/3 17.89 11.67 70RO 375/3 22.18 15.75 70RO 450/3 26.65 18.79 70RO 550/3 32.44 23 70RO 650/3 38.43 27.25 70RO 780/3 46.21 32.63 70RO 1000/3 55.48 41.67 75RO 1175/3 65.28 48.96 75RO 1350/3 75 56.25 75RO 1500/3 83.33 62.5 75RO 1700/3 94.57 70.83 75RO 1800/3 100 75 75RO 1900/3 105.56 79.17 75RO 2100/3 116.82 87.5 75RO 2400/3 133.51 100 75Feed water TDS up to 5000 ppmRO 100/5 6.33 4.17 70RO 175/5 11.13 7.29 70RO 250/5 15.93 10.42 70RO 350/5 22.32 14.67 70RO 400/5 25.46 16.75 70RO 500/5 31.61 20.83 70RO 600/5 38.46 25 70RO 700/5 44.39 29.17 70RO 900/5 53.57 37.5 70RO 1100/5 65.48 45.83 70RO 1250/5 74.4 52.08 70RO 1550/5 92.26 64.58 70RO 1650/5 98.21 68.75 70RO 1750/5 104.17 72.92 70RO 1950/5 116.07 81.25 70RO 2150/5 127.98 89.58 70
ytilauQ ylppuS retaW deeFsnoitacfiicepS lairetaM
Pressure Vessels FRP 400 psi Feed Water Design Temp. (°C) 15Pipework AISI 316L SCH40 for high pressure Max. SDI 3
Others: uPVC Max. Turbidity (NTU) 1Skid Epoxy coated carbon steel Max. TOC (ppm) 3Pump Material AISI 304 or 316L (depending on TDS) Iron (ppm) < 0.1Pump Type Centrifugal submersible multistage sleeved Manganese (ppm) < 0.1Control Cabinet Painted carbon steel to IP54 Free Chlorine (ppm) < 0.1Membranes Polyamide spiral wound (8”)
5x1.7x2.25x1.7x2.25x1.7x2.2
5.5x1.7x2.27.5x1.7x2.25.5x1.7x2.26.5x1.7x2.27.5x1.7x2.26.5x1.7x2.27.5x1.7x2.27.5x1.7x2.27.5x1.7x2.2
(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)
5x1.7x2.25x1.7x2.25x1.7x2.2
5.5x1.7x2.25.5x1.7x2.25.5x1.7x2.26.5x1.7x2.27.5x1.7x2.27.5x2x2.27.5x2x2.27.5x2x2.27.5x2x2.27.5x2x2.2
(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)
5x1.7x2.25x1.7x2.2
5.5x1.7x2.27.5x1.7x2.25.5x1.7x2.26.5x1.7x2.27.5x1.7x2.26.5x1.7x2.27.5x1.7x2.27.5x1.7x2.27.5x1.7x2.2
(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)(9x2x2.2) + (9x1.5x2.2)
140014501600170019002100220023002500320034503700
4300+43004550+45504800+48005000+50005500+5500
1400145015001600180021002350240025753200345037004000
4300+43004550+45504800+48005000+50005500+5500
9701100140016101600195022002575320034503700
4300+43004550+45504800+48005000+50005500+5500
236812121518202430304242485460
23681212151820243030364242485460
36812121518202430304242485460
2334681012151818242430303036
233468101215181824242430303036
334681012151818242430303036
7.59.211
18.518.5222630303745556375757592
131113
18.518.522303037455555637575929292
111322222230373755556375929292110
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
SIRION130 - 350 Series
™ Basic
Reverse Osmosis Systems
SIRION™ Basic reverse osmosissystems produce high puritywater, removing up to 98% ofdissolved inorganics and over99% of large dissolved organics,colloids and particles.
Flow rates from 100 to350 l/hr.
Features & Benefits• Low energy membranes result in
lower operating pressures; cost savings
• Simple instrumentation with manual pressure gauges and manual flow-meters; low cost
• Optimized flow: size ratio; space saving and efficient
• 1µm pre-filtration included within unit; membrane protection
• Programmable user interface; simple operation, monitoring of conductivity
• Dry run monitor; pump protection• Timed recirculation rinse; reduces
membrane fouling
Options• Treated water diverted at start-up;
ensures water quality• Monitoring of temperature
Applications• Air conditioning • Heating system• Boiler feed water
Related ServicesLocal after-sales service and support teams offer preventative and corrective maintenance programs to ensure the long-term, efficient operation of installed plant.
Hydrex® ChemicalsHydrex® 4000 water treatment chemicals from Veolia WaterSolutions & Technologies should be used for optimised operation.
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Basic 130-350 Series/AQF059_EN_V3.1
Model 130 250 350
Nominal Flows at 12°C
Permeate l/hr 100-130 200-250 300-350
Feed l/hr 125-175 250-335 375-470
Typical Salt Rejection % 96-98 96-98 96-98
Pump Motor Size kW 0.55 0.55 0.55
*Flow rates are dependent on feed water quality.All capacity data is referenced to 12°C water temperature and a feed water total salt contents of 750 ppm.
System Performance
Model 130 250 350
Height mm 1040 1260 1260
Depth mm 380 380 380
Width mm 600 600 600
Weight kg 59 61 68
System Dimensions
Model 130 250 350
Feed Water, Permeate, First Permeate, Concentrate 12 mm 12 mm 12 mm
Pipe Connections
Potable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure min. 2 bar max. 6 bar
Temperature min. 5°C max. 25°C
Feed Water Supply Quality
230V, 50Hz standard.
Electrical Supply
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
SIRION™ Basic (130 - 350 Series)
SIRION5000 - 20000 Series
™ Basic
Reverse Osmosis Systems
SIRION™ Basic reverse osmosis systems produce high purity water, removing up to 98% of dissolved inorganics and over 99% of large dissolved organics, colloids and particles.
Flow rates from 5 to 20 m3/hr.
Options• Anti-scalant/sodium bisulfate
dosing equipment • Treated water diverted at start-up;
ensures water quality
Features & Benefits• Low energy membranes result in
savings• 5µm pre-filtration included within
the unit for membrane protection• Programmable user interface;
simple operation, monitoring, conductivity and temperature values
• Dry run monitor; pump protection• Timed recirculation rinse; reduces
membrane fouling• Simple instrumentation with
manual pressure gauges and manual flow-meters; low cost
Applications• Air conditioning • Heating system• Boiler feed water
Related ServicesLocal after-sales service and support teams offer preventative and corrective maintenance programs to ensure the long-term, efficient operation of installed plant.
Hydrex® ChemicalsHydrex® 4000 water treatment chemicals from Veolia WaterSolutions & Technologies should be used for optimised operation.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Basic 5000-20000 Series/AQF061_EN_V2.1
Visit our website:www.veoliawaterst.com
Model 5000 7500 10000 15000 20000
Nominal Flows at 12°C
Permeate m3/hr 5 7.5 10 15 20
Feed m3/hr 6.3 9.4 12.5 18.8 25
Typical Salt Rejection % 96-99 96-99 96-99 96-99 96-99
Pump Motor Size kW 7.5 11 11 15 18.5
*Flow rates are dependent on feed water quality and Temperature, the above values are based on 1000 ppm TDS, 12°C.
Equipment Performance
Model 5000 7500 10000 15000 20000
Height mm 1800 1800 1800 1800 1800
Depth mm 860 860 860 860 860
Width mm 3350 3760 4775 4815 4900
Weight (dry) kg 950 1050 1100 1150 1300
System Dimensions
Model 5000 7500 10000 15000 20000
Feed DN40 DN40 DN50 DN50 DN65
Permeate DN40 DN40 DN40 DN50 DN50
Concentrate DN25 DN25 DN25 DN32 DN32
All connections are union socket - PVC-U.
Pipe Connections
Potable water free from organic contamination, chlorine and suspended matter. A softened water supply is normally required.
Supply Pressure min. 2 bar max. 6 bar
Temperature min. 5°C max. 30°C
Feed Water Supply Quality
All models 380/415V, 3 phase, 50Hz standard.
Electrical Supply
SIRION™ Basic (5000 - 20000 Series)
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
SIRION Sea WaterTM
Reverse Osmosis Systems
SIRION Sea Water TM reverse osmosis systems are specifically designed to treat seawater.They reject over 99% of the saltcontained within the feed water.
Flow rates for standard systemsrange from 1 to 41 m3/hr for feedwaters of up to 36 000 ppm (TDS).
Features & Benefits
• Standardized and skid-mounted;short lead times and quick start-up
• Small footprint; easily integratedinto existing plant
• Chemical pre-treatment; protectsthe RO membranes
• High pressure pump with variablefrequency drive; efficient and quietoperation
• Energy recovery device for highflow rate models; energy savings of 35-55%
• State-of-the-art RO membranes
• Flushing and chemical cleaning system; removes salt deposits, prevents scaling and maintains system performance
• Touch screen interface for easy operation
• PLC control
Applications
• Production of potable water
• Agricultural irrigation
• Industrial process water
Related Services
Local after-sales service and supportteams offer preventative and corrective maintenance programs toensure the long-term, efficient operation of installed plant.
Hydrex® Chemicals
Hydrex® 4000 water treatment chemicals from Veolia Water Solutions & Technologies should beused for optimized plant operation.
SIRION Sea WaterTM
Equipment Performance & Dimensions Flow @ 20°C
RecoveryDimensions Membranes Pump
Model rewoPytitnauQthgieWHxDxWetaemreP deeFm3/hr m3/hr % m kg - kW
D-25 5.30 1.06 20
D-50 6.42 2.12 33
D-75 7.95 3.18 40
D-100 10.60 4.24 40
D-125 13.25 5.30 40
D-150 15.88 6.35 40
D-190-PX 19.88 7.95 40
D-230-PX 23.88 9.55 40
D-270-PX 26.55 11.15 42
D-360-PX 35.36 14.85 42
D-450-PXD-450-T
44.17 18.55 42
D-530-PX 52.98 22.25 42
D-530-T 52.98 22.25 42
D-620-PX 61.90 26.00 42
D-620-T 61.90 26.00 42
D-710-PX 70.48 29.60 42
D-710-T 70.48 29.60 42
D-800-PX 79.45 33.37 42
D-800-T 79.45 33.37 42
D-890-PX 88.33 37.10 42
D-890-T 88.33 37.10 42
Material SpecificationsLow PressurePrefilter Housing Polyamide (PA)Filter Element PolypropyleneDosing Pumps PVC head, Teflon-coated EPDM diaphragmChemical Product Tanks PEFlushing and Chemical Cleaning Tank FRPFlushing and Chemical Cleaning Pump Stainless steelPiping and Accessories PVC-U / PN-16High PressureHigh-Pressure Pump Stainless Steel AISI 904-L / Super Duplex
(depending on the model)Pressure Vessels FRPRO Membranes Link crossed aromatic polyamide (8”)Piping and Accessories Stainless steel for seawater applications
AISI 904-L (Standard) ZERON/ 254 SMO (Options)Skid Epoxy-painted carbon steel
Feed Water Supply QualityRaw Water Design Temperature 02C°Raw Water Maximum Turbidity 1UTNRaw Water Minimum Pressure 3rabSDI <3
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Sea Water/AQF0017_EN_V3.0
3x1.7x2.2
3x1.7x2.2
4x1.7x2.2
5x1.7x2.2
6x1.7x2.2
4x1.7x2.2
6.5x1.7x2.2
8x2x2.2
8.5x2x2.2
8.5x2x2.2
9x2x2.2
9x2x2.2
10x2x2.2
9x2x2.2
10x2.15x2.2
9.5x2.15x2.2
10x2.15x2.2
9.5x2.15x2.2
10x2.15x2.2
9.5x2.15x2.2
10x2.15x2.2
9.5x2.15x2.2
1600
1700
1800
1900
2000
2100
2200
3100
3400
3700
4025
3975
4325
4275
4525
4475
4530
4500
4535
4525
4600
4550
2
4
6
8
10
12
15
18
21
28
35
35
42
42
49
49
56
56
63
63
70
70
18.5
22
22
2x15
2x22
2x22
22+2.2
30+2.2
2x18.5+3
2x22+3
2x30+4
75
55+5.5
75
55+5.5
110
75+7.5
110
75+7.5
11.
90+7.5
132
44.17 18.55 42
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
Ultrafi ltration
Ultrafi ltration is a membrane separation process similar to microfi dna noitartl reverse osmosis. However, it diff ers in terms of the size of particles removed and its operation. Ultrafi ltration operates at low pressures and is capable of removing suspended solids including fi thgiew ralucelom hgih dna sdiolloc ,setalucitrap en dissolved materials.
Applications include: Surface water Borehole water Swimming pool water Recycling/reuse RO feed water Oil/water separation in emulsion Recovery of metal particles Regeneration of degreasing/cleaning solutions
Ultrafi ltratioon
Ultr
afi lt
ratio
n
2.5 to 44
2.5 to 176
55
55
11 165 220
110 165 220
2.5 - 11 5 - 22 7.5 - 33 10 - 44
55 11 165 2202236/2156* 2236/2156* 2252/2178* 2276/2194*
1648 1657 2635 2655
50 50 50
3 - 19 Aug.2013
Deionisation
There are many industrial processes in which the presence of any dissolved salts in water can cause problems. Removing all the dissolved salts from water is called deionisation or demineralisation. Processes that need high purity water include:
High pressure boilers Chemical manufacture Toiletries and cosmetics production Humidifi cation systems Battery top-up Surface fi nishing
For industrial processes requiring high purity water, the most widely used purifi cation technology is twin bed ion exchange deionisation. The ion exchange resins are contained in two separate pressure vessels and fl ow through them in series. Raw water enters the cation exchange vessel and passes down through the resin bed where calcium, magnesium, sodium and other cations are removed from the water in exchange for hydrogen ions. The water then passes through the anion exchange vessel where chloride, sulfate, bicarbonate and other anions are removed in exchange for hydroxide ions. When the hydrogen and hydroxide ions on the resins have been replaced by the cations and anions from the water, the deionisation reaction stops and the resins need to be regenerated.
Deionisationn
Dei
onis
atio
n
004003051
m3 0.4 - 0.10.3 - 5.05.1 - 52.0rh/
0.6 - 0.40.6 - 0.40.6 - 0.4rab
0.38.26.1rab
0.35.38.2sruoh
m3 0.48.20.2rh/
m3 0.26.10.1
530201l
l
l
143211
5.734201
m3 0010652
004003051
050256915051mm
007076076mm
05210701078mm
000100010001mm
000100010001mm
059538084gk
111sehcni
111sehcni
111sehcni
004003051
02<01<01<l/gm
02< :egarevA 03< :mumixaMmc/Sμ
Continuous Electrodeionisation (CEDI)
Continuous Electrodeionisation (CEDI) is a technology combining ion exchange resins and ion-selective membranes with direct current to remove ionised species from water. It overcomes the limitations of ion exchange resin beds, notably the release of ions as the beds exhaust and the associated need to change orregenerate the resins. Reverse osmosis (and sometimes membrane degassing) is typically used prior to CEDI to ensure that the CEDI stack is not overloaded with high levels of salts.
Applications include: Pharmaceutical High pressure boiler feed Humidifi cation systems Microelectronics Central laboratory
Continuous Eleectrodeiionisatiion (CEDDI)
CED
I
Ultraviolet Disinfection
Ultraviolet (UV) technology is an eff retaw rof ygolonhcet eerf-lacimehc evitce disinfection.
UV disinfection can be applied to: Process water Wastewater
An ultraviolet (UV) disinfection system transfers electromagnetic energy from a mercury arc lamp to organisms’ genetic material. UV radiation, generated by an electrical discharge through mercury vapour, penetrates the microorganisms and destroys or slows down their ability to reproduce. The eff ectiveness of a UV disinfection system depends on the characteristics of the water, the intensity of UV radiation, the amount of time the microorganisms are exposed to the radiation, and the reactor confi guration. For any one treatment plant, disinfection success is directly related to the concentration of colloidal and particulate constituents in the water.
Ultraviolet DDisiinfectioon
UV
Dis
infe
ctio
n
UV Water TreatmentUV Disinfection - Industrial range
Ultra Violet (UV) technology is an effective chemical-freetechnology for water disinfection.
Capacity: up to 112 m3/hr for disinfection
Features & benefits:
• Compact, easy to install ; can be mounted horizontally or vertically depending the models
• Conveniently fit into existing pipework
• Easy to maintain and operate
• Low operation cost
• Silent operation
• Chemical-free process ; safety
• Environmentally-friendly: No production of toxic by-products
• Typical lamp operating life of up to 16,000 hours
• No effect on pH, colour, flavour or aroma
• No detrimental effect on product stability
• No residue
• Overdosing not possible
• UV Chamber in 316L stainless steel construction
• Quick replacement of Arc Tubes
• Optional UV monitor
Applications
• Production of pure water
• Electronics and semiconductor industry
• General industries
• Destruction of residual ozone after disinfection and sanitisation (deozonisation)
Related services
Local after-sales service andsupport teams offer preventative and corrective maintenanceprograms to ensure the long-term, efficient operation of installed plant.
Visit our website:www.veoliawaterst.com
Model Max Flow
m3/hr
Power
W
Dia
mm
Length
mm+/- 5mm
Weight
kg
Connections
PN16 Flange
A B Lamp Total Empty Full
UV 35 i 3.5 3.6 80 105 63 920 5 6 1’’
UV 64 i 6.4 7.2 80 105 102 958 7 12.5 1½’’
UV 127 i 12.7 14.1 140 170 102 1385 9 17.5 2’’
UV 230 i 23 23 270 320 102 1385 9 17.5 2’’
UV 468 i 46.8 56 270 320 168 1437 25 52 3’’
UV 900 i 89 112 550 630 206 1985 46 107 6’’
A – Disinfection at 26mJ/cm2 RED MS2 Phage, 95% T10 transmittance at the end of lamp lifeB – Disinfection at 26mJ/cm2 RED MS2 Phage, 98% T10 transmittance at the end of lamp life
Specifications
Material AISI 316L : DN 1.4404 Water Temperature +5 to +40°C
Finish External Passivated & Electropolished Maximum CIP Temperature 95°C
Protection IP65 / NEMA 4 Finish internal: As made pipe and tube, welds left as laid,
electropolished and passivated
Finish internal: As made pipe and tube, welds left as laid,
electropolished and passivated
Pressure 9 bar, max operating* * UV 900i 6 Bar max operating pressure
Mounting Horizontal or Vertical** *Note UV900i cannot be mounted vertically
UV Chamber Specifications
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/UV Water Treatment - Industrial range/ AQF060_EN_V2.0
Enclosure Material Powder Coated Carbon Steel
Power Supply 230V 50/60Hz
Cable 5m maximum Control Box to UV Chamber
Ambient +5 to +40°C
Indicator Lamps Lamp On + Fault
Output (VFC) Lamp On
UV 35 i – UV 468 i IP65 / NEMA 4
Dimensions/Weight 400 x 300 x 155 mm(excl Brackets) 15kg
UV 900 i IP55 / NEMA12
Dimensions/Weight 600 x 400 x 210 mm(excl Brackets) 19kg
Control Box Specifications
Long life 254Nm amalgam lamp.Lamp Life – Expected 16,000 hours (12,000 Hours UV230i, UV468i & UV900i) Warranty 9,000 hours. Based on less than 4 start/stop cycles per 24 hours.
UV Lamp Specifications
All units are supplied with a Certificate of Conformity.
Documentation
UV Water Treatment - Industrial range
UV Water TreatmentUV Disinfection - Pharma range
Ultra Violet (UV) technology is an effective chemical-freetechnology for water disinfection:Versions built to cGMP requirements available for pharmaceutical and sanitary applications.
Capacity: up to 112 m3/hr for disinfectionup to 19.6 m3/hr for deozonisation
Features & benefits:
• Compact, easy to install ; can be mounted horizontally or vertically depending the models
• Conveniently fit into existing pipework
• Easy to maintain and operate
• Low operation cost
• Silent operation
• Chemical-free process ; safety
• Environmentally-friendly: No production of toxic by-products
• Typical lamp operating life of up to 16,000 hours
• No effect on pH, colour, flavour or aroma
• No detrimental effect on product stability
• No residue
• Overdosing not possible
• UV Chamber in 316L stainless steel construction
• Quick replacement of Arc Tubes
• Optional UV Monitor
Applications
• Production of pure water
• Pharmaceutical
• Destruction of residual ozone after disinfection and sanitisation (deozonisation)
• Cosmetics and toiletries industry
Related services
Local after-sales service andsupport teams offer preventative and corrective maintenanceprograms to ensure the long-term, efficient operation of installed plant.
Visit our website:www.veoliawaterst.com
Model Max Flow
m3/hr
Power
W
Dia
mm
Length
mm+/- 5mm
Weight
kg
Connections
TC – Triclamp Inches
A B Lamp Total Empty Full
UV 36P 3.6 0.45 80 105 63 920 5 6 1’’
UV 72P 7.2 1.42 80 105 102 958 7 12.5 1½’’
UV 141P 14.1 2.3 140 170 102 1385 9 17.5 2’’
UV 230P 23 4.5 270 320 102 1385 9 17.5 2’’
UV 560P 56 8.4 270 320 168 1437 20 47 3’’
UV 1120P 112 19.6 550 630 206 1985 39 100 6’’
A – Disinfection at 26mJ/cm2 RED MS2 Phage, 98% T10 transmittance at the end of lamp lifeB – Deozonisation is based on a 90% reduction of Ozone at 98% T10 transmittance at the end of lamp life
Specifications
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/UV Water Treatment - Pharma range / AQF078_EN_V1.1
Enclosure Material Powder Coated Carbon Steel
Power Supply 230V 50/60Hz
Cable 5m maximum Control Box to UV Chamber
Ambient +5 to +40°C
Indicator Lamps Lamp On + Fault
Output (VFC) Lamp On / Low UV
UV 36 P – UV 560P IP65 / NEMA 4
Dimensions/Weight 400 x 300 x 155 mm(excl Brackets) 18kg
UV 1120P IP55 / NEMA12
Dimensions/Weight 600 x 400 x 210 mm(excl Brackets) 22kg
Control Box Specifications
Long life 254Nm amalgam lamp.Lamp Life – Expected 16,000 hours (12,000 Hours UV230P, UV560P & 1120P) Warranty 9,000 hours. Based on less than 4 start/stop cycles per 24 hours.
UV Lamp Specifications
All units are supplied with a Certificate of Conformity, with material certificates, lamp output certificates & FDA Validation pack.
Documentation
UV Water Treatment - Pharma range
Material AISI 316L : DN 1.4404 Water Temperature +5 to +40°C
Finish External Passivated & Electropolished Maximum CIP Temperature 95°C
Protection IP65 / NEMA 4 Finish, Internal < 0.5μm Ra
Pressure 9 bar, max operating* * UV1120P 6 Bar max operating pressure
Mounting Horizontal or Vertical** ** UV1120P cannot be mounted vertically
**Photo includes the UV Monitor.
UV Chamber Specifications
Multi-Technology Solutions
Water treatment technologies are diff erentiated by their ability to treat diff tnere types of contaminants. It is often necessary to combine diff erent treatment technologies in order to produce a suitable quality of water for an application.
Applications include: Filtration, softening and RO for utility feed and process water Filtration, softening, RO and DI for healthcare, microelectronics and laboratories Filtration, softening, twin pass RO and CEDI for pharmaceutical RO & CEDI for high pressure boiler feed RO & CEDI for healthcare, microelectronics and central laboratory
The existence of similar applications and thus water requirements across diff erent businesses has encouraged water treatment companies to propose pre-packaged multi-technology solutions. Typically such solutions are skid-mounted or containerised and have smaller footprints than combined independent technologies. They also have the advantage of being pre-piped and pre-confi gured prior to delivery for quick installation and start-up. In addition, the control systems are specifi cally designed to monitor and control the combined technologies making for an effi cient and easy to use system.
Multi-Technooloogy Soluutions
Mul
ti-Te
chno
logy
So
lutio
ns
000300020001005rh/l
011404720731096rh/l
0111047073091rh/l
5.75.50.40.3Wk
37%
23520202mm
52025151mm
52025101mm
05mm
003105220602mm
Clarifi cation & Flotation
Clarifi cation is a multi-step process that reduces turbidity and suspended matter. It is also used to reduce iron and remove colour, taste and odour in the water by adding oxidising agents such as chlorine. Clarifi cation consists of three stages: coagulation, fl occulation and sedimentation.
During the coagulation stage, chemical coagulants or pH-adjustment chemicals are used to destabilise the particles. During the fl occulation stage, other chemicals are added which encourage the previously destabilised particles to stick together and form fl ocs. During sedimentation, the fl ocs settle by gravity and separate from the water.
Applications include: Primary clarifi cation of wastewater Treatment of biofi lter backwash water Clarifi cation of trickling fi lter effl uents Storm water treatment Tertiary polishing or phosphorus removal Drinking water treatment, both ground and surface waters Giardia and cryptosporidium removal Pre-treatment of industrial process waters Recycling/reuse
Flotation DAF is a process using air dissolved in water in order to achieve solid/liquid separation.In order to increase the process effi ciency, chemical additives are normally dosed. Coagulation followed by fl occulation inside the treated fl uid is achieved.Coagulation is meant to destabilise solid particles in stable equilibrium inside the fl uid, while fl erom dna reggib otni selcitrap eht rehtag ot tnaem si noitalucco extended fl ocs.
Clarifi cationn & Flotatioon
Clar
ifi ca
tion
& F
lota
tion
Actiflo® MiniThe Ultimate MicrosandEnhanced Clarifier
The pre-engineered Actiflo® Mini is a very compact standard package plant for drinking water treatment, municipal wastewater treatment as well as industrial process water and wastewater treatment and reuse. The process is a highly efficient and proven clarification technology based on a strong 20+ year operating experience and over 750 references worldwide (2012).
In Actiflo® Mini, water is flocculated with microsand and polymer. The microsand enhances the formation of robust flocs and acts as ballast, significantly increasing their settling velocity. The unique characteristics of the resulting microsand ballasted flocs allow for clarifier designs with very short retention times, high rise rates and extremely compact system footprints that are up to 50 times smaller than other clarification processes of similar capacity. A hydrocyclone ensures the microsand continuous cleaning, recovery and reuse in the process.
Unit flow rates: - Drinking and process water: from 3 to 7 m3/hr- Wastewater: from 3 to 15 m3/hr
Features & Benefits•High treatment efficiency: Turbidity
and TSS removal up to > 99%; treats all water and wastewater sources
•Extremely quick start-up time: Reaches treatment efficiency within few minutes
•Process stability: The microsand buffers the effect of raw water flow or load variations, making the process very user friendly and easy to operate
•Quick optimization: Short hydraulic retention time makes it feasible for the process to adjust quickly to changing raw water quality
•Efficient use of chemicals: Microsand ballasted flocculation and settling helps to avoid common chemical overdosing to achieve good clarification performance
•Efficient in cold water applications: Suitable for use also in Nordic regions
•Compact design: Can be easily integrated and retrofitted into existing structures
•Modular: Units may be combined to achieve treatment of high flow rates
Related ServicesLocal after-sales service and support teams offer preventive and corrective maintenance programs to ensure long-term, efficient operation of installed plant.
Applications•Surface and ground water treatment
•Very high or very low turbidity water and wastewater
•Treatment of water with high natural organic matter (colour, TOC)
•Efficient treatment of algae, phosphorus, heavy metals, oil & grease, particle counts, crypto and giardia, coliforms, etc.
•Primary, secondary and tertiary clarification of wastewater
•Treatment of biofilter backwash water and trickling filter effluents
•Stormwater and combined sewer overflow treatment, reverting to effluent polishing during dry weather
•Industrial process water treatment for cooling tower make-up or prior to demin plants
•Pre-treatment to membrane and ion exchange systems
•Industrial wastewater treatment in all market segments, including leachate and run-off water
•Recycling/Reuse of municipal and industrial effluents
Hydrex® ChemicalsHydrex® 3000 & 6000 water treatment chemicals from Veolia Water Solutions & Technologies should be used for optimized plant operation.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Actiflo® Mini/AQF0124_EN_V1.1
Visit our website:www.veoliawaterst.com
Process & Drinking Water Application 3(*) - 7 m3/H
Industrial & Municipal Wastewater Application 3(*) - 15 m3/H
Length 3 m
Width 1 m
Height 2.7 m
Operating Weight 3.4 tonne
Total Installed Power max. 4kW
Supply Power (Standard) (**) 380V x 3phase x 50/60 Hz
Recirculation Pump 3.5 m3/H x 20mH x 2.2 kW
Chemical Dosing Pump (Standard) (***) PAC, Acid, Alkali, Polymer
Monitoring Instrument (Standard) (****)
1 x pH at Coagulation Tank3 x Flowmeter at Inlet, Recirculation & Sludge Line
1 x Pressure at Hydrocyclone Inlet2 x Turbidity Meter at Inlet & Outlet
Equipment Performance & Dimensions
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
Actiflo® Mini
(*) In case of the operation at < 5 m3/H, the separation of sludge from microsand should be investigated, due to over-mixing in Maturation Tank.(**) 220V x 3 phase x 50/60Hz is optional.(***) Additional chemical dosing or different type of chemical should be discussed prior to the order.(****) Additional monitoring should be discussed prior to the order.
Actiflo® Mini is supplied as a complete functional system, including chemical preparation and dosing equipment as well as integrated PLC & SCADA.It can be supplied as a stand-alone unit or pre-installed in a 20’ container.
0804
06108
023061
046023
06108
023061
046023
0821046
4.2
4.8
4.8
4.8
8.11.4
4.2
4.8
4.8
4.8
4.21.5
7.27.5
6.32.8
8.11.4
4.21.5
7.27.5
6.32.8
Actiflo® Turbo PackThe Ultimate MicrosandEnhanced Clarifier
The pre-engineered Actiflo® Turbo Pack is a very compact standard package plant for drinking water treatment, municipal wastewater treatment as well as industrial process water and wastewater treatment and reuse. The process is a highly efficient and proven clarification technology based on a strong 20+ year operating experience and over 750 references worldwide (2012).
In Actiflo® Turbo, water is flocculated with microsand and polymer in a Turbomix draft tube. The microsand enhances the formation of robust flocs and acts as ballast, significantly increasing their settling velocity. The unique characteristics of the resulting microsand ballasted flocs allow for clarifier designs with very short retention times, high rise rates and extremely compact system footprints that are up to 50 times smaller than other clarification processes of similar capacity. A hydrocyclone ensures the microsand continuous cleaning, recovery and reuse in the process.
Unit flow rates from 1 500 m3/d to 43 000 m3/d.
Features & Benefits•High treatment efficiency: Turbidity
and TSS removal up to > 99%; treats all water and wastewater sources
•Extremely quick start-up time: Reaches treatment efficiency within few minutes
•Process stability: The microsand buffers the effect of raw water flow or load variations, making the process very user friendly and easy to operate
•Quick optimization: Short hydraulic retention time makes it feasible for the process to adjust quickly to changing raw water quality
•Efficient use of chemicals: Microsand ballasted flocculation and settling helps to avoid common chemical overdosing to achieve good clarification performance
•Efficient in cold water applications: Suitable for use also in Nordic regions
•Compact design: Can be easily integrated and retrofitted into existing structures
•Modular: Units may be combined to achieve treatment of high flow rates
Related ServicesLocal after-sales service and support teams offer preventive and corrective maintenance programs to ensure long-term, efficient operation of installed plant.
Applications•Surface and ground water treatment
•Very high or very low turbidity water and wastewater
•Treatment of water with high natural organic matter (colour, TOC)
•Efficient treatment of algae, phosphorus, heavy metals, oil & grease, particle counts, crypto and giardia, coliforms, etc.
•Primary, secondary and tertiary clarification of wastewater
•Treatment of biofilter backwash water and trickling filter effluents
•Stormwater and combined sewer overflow treatment, reverting to effluent polishing during dry weather
•Industrial process water treatment for cooling tower make-up or prior to demin plants
•Pre-treatment to membrane and ion exchange systems
•Industrial wastewater treatment in all market segments, including leachate and run-off water
•Recycling/Reuse of municipal and industrial effluents
Hydrex® ChemicalsHydrex® 3000 & 6000 water treatment chemicals from Veolia Water Solutions & Technologies should be used for optimized plant operation.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Actiflo® Turbo Pack/AQF0123_EN_V1.1
Visit our website:www.veoliawaterst.com
Model
Flows (m3/d)
60 m/h 80 m/h(Drinking / Process Water)
120 m/h(Municipal / Industrial Wastewater)
ACP2-15 1 500 2 000 3 000
ACP2-30 3 000 4 000 6 000
ACP2-40 4 500 6 000 9 000
ACP2-45 6 000 8 000 12 000
ACP2-55 9 000 12 000 18 000
ACP2-60 12 000 16 000 24 000
ACP2-70 18 750 25 000 37 500
ACP2-75 21 375 28 500 42 750
ModelDimensions (mm)
Length WidthHeight
(Tank) (Assembled)
ACP2-15 4 156 2 029 2 859 4 479
ACP2-30 5 744 2 254 3 175 4 794
ACP2-40 6 824 2 580 3 315 4 970
ACP2-45 6 871 2 668 3 175 5 177
ACP2-55 8 374 3 278 3 175 5 177
ACP2-60 9 352 3 990 3 175 5 177
ACP2-70 10 651 4 500 3 650 5 648
ACP2-75 11 830 4 612 3 650 5 648
Equipment Performance
Unit Dimensions
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
Actiflo® Turbo Pack
Membrane Bioreactors & Biological Wastewater Treatment
Membrane Bioreactors (MBR) are used to treat industrial and municipal wastewaters to produce high quality effl uents suitable for water reuse applications – either directly or following a reverse osmosis treatment stage. MBR combine two basic processes: biological treatment and membrane separation in either a single tank or separate tanks. The biological breakdown of the pollution takes place in an aerated reactor containing suspended microorganisms (biomass or activated sludge). The keydiff erentiator of MBR is that the biological process is coupled with membranes for biomass fi sa hcus ,sessecorp noitarapes lanoitnevnoc gnisu fo daetsni noitartl clarifi cation and fl otation.
Advantages over conventional systems: Small footprint and quick start-up Complete suspended solids removal High load rate capability High removal of COD and nutrients (nitrogen, phosphorous) Low sludge production No sludge bulking Effl uent disinfection; barrier against pathogens, such as chlorine-resistant
organisms, cryptosporidium and giardia
Applications include: Small or medium sized industrial or municipal effl uent treatment plants Temporary solutions during refurbishment or upgrade work Recycling for boiler feed, process water, aquifer recharge, public utility
Membrane BBiooreactorrs & Bioological Wastewaterr Treeatmennt
MBR
& B
iolo
gica
l w
aste
wat
er
trea
tmen
t
Biosep™ Pack 3Membrane Bioreactor (MBR)
Features & Benefits
Standardised systems; short leadtimes and quick start-up
Skid-mounted, modular design; easily integrated into existingplant, extensible
Integrated filtration and membranecleaning system
Suitable for all types of effluent, easily integrated into a wide varietyof biological designs; highly flexible
Compared to conventional activated sludge:
Compact solution; less equipmentand civil engineering, simplifiedtreatment line
No settler; no risk of sludge loss,performance independent of sludge index
Long biomass retention time; highCOD removal, including slowly biodegradable COD
Applications
Small or medium sized industrial
or municipal effluent treatment
plants (800 to 10,000 PE)
Temporary solutions during
refurbishment or upgrade work
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Hydrex® Chemicals
Hydrex® 4000 & 7000 water
treatment chemicals from Veolia
Water Solutions & Technologies
should be used for optimized plant
operation.
Biosep™ Pack is added to a biological aeration tank. The membrane bioreactor replaces the traditional settling system and separates perfectly the purifying biomass from thetreated effluent through microfiltration. The microfiltered water is of excellentbacteriological quality and removal of TSS is guaranteed at any time.
Flow rates from 4 to 110 m3/hr.
Biosep™ PackEquipment & Dimensions
Membrane Tank Membrane
PowerBackwash Air
BSP 1 M 5BSP 1 M 10 BSP 1 M 15 BSP 2 M 20BSP 2 M 30
04 - 12
08 - 33
12 - 56
16 - 66
24 - 110
1
1
1
2
2
2.5
3
4
3
4
6 - 8
6 - 8
6 - 8
6 - 8
6 - 8
20
29
52
29
52
0.006 - 6
0.006 - 6
0.006 - 6
0.006 - 6
0.006 - 6
2
3 or 4
3 or 6
3 or 4
3 or 6
5.5
11
15
18.5
30
150
300
450
600
900
10
12
15
24
30
1
1
1
2
2
Typical PerformancesCOD < 50mg/l*BOD5 < 5 mg/lSuspended Solids < 3mg/l (detectable threshold)Total Nitrogen < 10-15 mg/l
Mod
els
Net
Flow
Rate
s (m
3 /hr
)
Num
ber o
f Mem
bran
e M
odul
es
Dia
met
er (m
)
Tota
l Hei
ght (
m)*
Net
Vol
ume
(m3 )
Antif
oam
Dos
ing
Pum
p (l/
h)
Dosa
tron
or B
ackw
ash
Pum
p So
lutio
n (m
3 /h)**
Ai
r Blo
wer
Pow
er (k
W)
Air B
low
er F
low
Rat
e (m
3 /h)
Mai
n Co
ntro
l Cen
ter P
ower
(kW
)
9882 FICHE BIOSEP PACK (Gb):Mise en page 1 29/05/08 22:29 Page 2
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Biosep™ Pack/AQF0034_EN_V3.1 - 11.2012
Total Phosphorous < 0.5 - 2 mg/lTurbidity < 1 NTUE.coli < 1000/100ml
Material SpecificationsMembrane Tank Fiber Reinforced Platsic (FRP)Access Fittings (ladder, platform, guard rails) Epoxy Coated or 304 LSkid PEPiping PE / PVC / PVC-C
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company.
Num
ber o
f Mem
bran
e Ta
nks
Antifoamskid
*Membrane tank height must be selected with site constraints (aeration basin and discharges levels)**2 backwash solutions are available, it must be chosen depending on potable water availability (3m3/h at 1 bar minimum)
*COD depends on the non-biodegradable (hard COD) fraction
Evaporation
Evaporation is a process of physical separation which can be applied to liquid systems. Evaporation technology is a natural and clean method of separation; for this reason it has become recognised as BAT (Best Available Technology) in several European Directives for waste treatment.
Typical applications include: Wastewater treatment Reduction of volumes to be disposed ZLD Recycling and Reuse Exploitation of exceeding thermal energy Production of high quality deionised water for boiler feed and cooling circuits
make-up Treatment of cooling towers blow-down
Evaporation
Evap
orat
ion
Mobile Water Solutions
Veolia Water Solutions & Technologies off ers Aquamove™ service to industries using purifi ed water for their production lines or utilities. Aquamove™ constitutes a large fl eet of mobile water treatment units, that may be deployed as stand-alone units or combined to form complete systems: skid-mounted systems, containers and trailers.
Aquamove™ off ers emergency hire, planned temporary hire and long-term contract for: Boiler, turbine feed water Process water Cooling water Drinking water Wastewater
Aquamove™ safeguards the production of the purifi ed water when clients are facing: Plant commissioning Filling pressure boilers Equipment breakdown Plant downtime for maintenance purposes Raw water changes Peak demand Process trial validation
Technologies available: Reverse osmosis Deionisation Ion exchange polishing Softening Filtration Activated carbon Clarifi cation Evaporation, …
Mobile Wateer SSolutionns
Mob
ile W
ater
Solu
tions
Water Treatment Chemicals
Veolia operates more than 5000 water treatment facilities across the world, including process, boiler feed, cooling water, waste water and sludge treatment. Our research & development team constantly innovates and delivers new technologies that provide optimum solutions to environmental problems with a high-value to our clients’ businesses. Hydrex™ chemicals are committed to complying with all chemical regulations (ie Reach, Biocides Directive in Europe,…).
Veolia Water Solutions & Technologies off eht esimitpo ot margorp ™xerdyH sre entire water cycle, chemical consumption, operating and maintenance costs.
Protecting water treatment systems against scale deposition, corrosion, fouling, etc. Reducing unnecessary downtime Ensuring optimum productivity Preventing and reducing environmental risks Allowing energy saving
Hydrex™ range includes: 1000 Series:Total boiler water treatment chemicals 2000 Series: Closed and open cooling system treatment programs 3000 Series: Drinking water production 4000 Series: Eff ective membrane antiscalants and cleaners approval by major
membrane manufacturers 5000 Series: Industrial maintenance chemicals 6000 Series: State-of-the-art clarifi cation and wastewater chemistry and
application experience 7000 Series: Biocides with a broad spectrum of activity and Legionella control 8000 Series: Established process and specialty chemicals 9000 Series: Wide range of other applications
Wat
erTr
eatm
ent
Chem
ical
s
Consumables & Spare Parts
Veolia Water Solutions & Technologies works in partnership with its customers to ensure the optimal running of their water treatment facilities.
Veolia Water Solutions & Technologies off ers a wide range of consumables and spare parts.
Cartridge fi lters Reverse osmosis membranes Ion exchange resins Activated carbon and other fi ltration media CEDI stacks Valves Instrumentation Dosing systems UV systems Test kits, etc.
Cons
umab
les
& S
pare
Par
ts
FILOTM CarbCartridge Filters
Features & Benefits
• Effective carbon surface areafor good chlorine reductionLow pressure lossLong lifeSeveral lengths available:9" 3/4 ; 20" ; 26" ; 30" ; 40"
•
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Chlorine reductionTaste and odour removalMembrane pre-treatmentProcess waterOrganic reduction in plating bathsRemoval of surfactant
•
The FILOTM Carb cartridge filters
are a range of activated carbon
filters.
Nominal rating: 10 μm.•
••••••
200
100
0
3
2
1
0
0 2 4 6
Diff
eren
tia
l Pre
ssu
re (
psi
d)
Flow Rate (l/min) for Water at 20°C
Performance
Diff
eren
tia
l Pre
ssu
re (
mb
ar)
Applications
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Carb/AQF113_EN_V1.2
FILOTM CarbSpecifications
Ordering Information
Length Micron End Fiting Part Number
9" 3/4 10 CFCBYS9510
CFCBZD9514
SOE CODE 3 CFCBZD9540
26" 10 SOE CODE 3 CFCBZD9541
SOE CODE 3 CFCBZE9540CFCBZE9512
SOE CODE 3 CFCBZF9512
CFCBZF9513
DOE
DOE
DOE
DOE
20"
30"
40"
10
10
10
Filtration Media Steam activated, Acid washed coal
Material Specifications
Recommended Operating Conditions
Max. Temperature 50°C (120°F)Max. Recommended Differential Pressure 1.5 bar (22 psid)
Dimensions
Outside Diameter 2.7"Inside Diameter 1.1"
Performance
Chlorine Reduction per 10" based on 2 ppm Inlet Concentration 22700 litres @ 3.8 l/min (6000 gallons @ 1 gpm)
FILOTM Carb-HPCartridge Filters
Features & Benefits
• Effective carbon surface areafor good chlorine reductionLow pressure lossLong lifeSeveral lengths available:9" 3/4 ; 20" ; 30" ; 40"
•
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Chlorine reductionTaste and odour removalMembrane pre-treatmentProcess waterOrganic reduction in plating bathsRemoval of surfactant
•
The FILOTM Carb-HP cartridge
filters are a range of high
performance activated carbon
filters.
Nominal rating: 1 μm.
•
••••••
400
200
0
6
4
2
0
0 2 4 6
Diff
eren
tia
l Pre
ssu
re (
psi
d)
Flow Rate (l/min) for Water at 20°C
Performance
Diff
eren
tia
l Pre
ssu
re (
mb
ar)
Applications
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Carb-HP/AQF114_EN_V1.2
FILOTM Carb-HPSpecifications
Ordering Information
Filtration Media Steam activated, Acid washed coal
Material Specifications
Recommended Operating Conditions
Max. Temperature 50°C (120°F)Max. Recommended Differential Pressure 1.5 bar (22 psid)
Dimensions
Outside Diameter 2.7"Inside Diameter 1.1"
Performance
Chlorine Reduction per 10" based on 2ppm inlet Concentration 76000 litres @ 3.8 l/min (20000 gallons @ 1 gpm)
Length Micron End Fiting Part Number
9" 3/4 1 CFCBYS9511
20" 1 CFCBZD9515
SOE CODE 3 CFCBZE9541
CFCBZE9513
SOE CODE 3 CFCBZF9541CFCBZF9514
DOE
DOE
DOE
DOE
30" 1
40" 1
FILOTM PleatCartridge Filters
Features & Benefits
• Cost effective high surface areaAbsolute rating from 1 to 25 micronsLong lifeSeveral lengths available:9" 3/4 ; 20" ; 30" ; 40"Endcaps available FDA approvedAll polypropylene construction
••
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Water pre-filtrationWater final filtration
•
The FILOTM Pleat cartridge filters
are dedicated to water pre-
filtration and final filtration of a
wide range of water treatment
applications.
Absolute rating from 1 to 25 μm. •
•
•
•
•
Applications
Performance
200
100
0
3
2
1
0
0 10 20 30
Diff
eren
tia
l Pre
ssu
re (
psi
d)
Flow Rate (l/min) for Water at 20°C
(Performance FILOTM Pleat 10")
Diff
eren
tia
l Pre
ssu
re (
mb
ar) 1 μ
m
5 μm
10 μm
25 μm
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Pleat/AQF115_EN_V1.1
FILOTM PleatSpecifications
Ordering Information
Filtration Media PolypropyleneEnd Caps Polypropylene / Nylon
Material Specifications
Recommended Operating Conditions
Max. Temperature 65°C (150°F)
Max. Recommended Differential Pressure 2.5 bar
Max. Differential Pressure 4 bar
Dimensions
Outside Diameter 2.7" (68 mm)
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYKYS9410 DOE CFYKZE9411
CODE 7 CFYKYS9450 CODE 7 CFYKZE9451
CODE 3 CFYKYS9440 CODE 3 CFYKZE9441
DOE CFYOYS9411 DOE CFYOZE9411
CODE 7 CFYOYS9450 CODE 7 CFYOZE9452
CODE 3 CFYOYS9440 CODE 3 CFYOZE9441
DOE CFYTYS9410 DOE CFYTZE9410
CODE 7 CFYTYS9450 CODE 7 CFYTZE9450
CODE 3 CFYTYS9440 CODE 3 CFYTZE9440
DOE CFZDYS9410 DOE CFZDZE9410
CODE 7 CFZDYT9450 CODE 7 CFZDZE9450
CODE 3 CFZDYS9440 CODE 3 CFZDZE9440
DOE CFYKZD9411 DOE CFYKZF9410
CODE 7 CFYKZD9451 CODE 7 CFYKZF9450
CODE 3 CFYKZD9441 CODE 3 CFYKZF9440
DOE CFYOZD9411 DOE CFYOZF9410
CODE 7 CFYOZD9451 CODE 7 CFYOZF9450
CODE 3 CFYOZD9441 CODE 3 CFYOZF9440
DOE CFYTZD9410 DOE CFYTZF9410
CODE 7 CFYTZD9450 CODE 7 CFYTZF9450
CODE 3 CFYTZD9440 CODE 3 CFYTZF9440
DOE CFZDZD9410 DOE CFZDZF9410
CODE 7 CFZDZD9450 CODE 7 CFZDZF9450
CODE 3 CFZDZD9440 CODE 3 CFZDZF9440
25
9" 3/4
20"
30"
40"
1
5
10
25
1
5
10
25
1
5
10
25
1
5
10
FILOTM Pleat-HPCartridge Filters
Features & Benefits
• Cost effective high surface areaAbsolute rating from 0.6 to 40 micronsLong lifeSeveral lengths available:10" ; 20" ; 30" Endcaps available: DOE, Code 7Code 3 FDA approvedAll polypropylene construction
••
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Water pre-filtrationWater final filtration
•
The FILOTM Pleat-HP cartridge
filters are offering an absolute
rated polypropylene media
with a broad range of chemical
compatibility.
The graded filter density along
with the optimised pleating
gives FILOTM Pleat-HP an
exceptional lifetime.
Absolute rating from 0.6 to 40 μm
(> 99.99% retention at micron
rating)
•
•
•
•
•
Applications
Performance
100
50
0
1
0
0 10 20
Diff
eren
tia
l Pre
ssu
re (
psi
d)
Flow Rate (l/min) for Water at 20°C
(Performance FILOTM Pleat 10")
Diff
eren
tia
l Pre
ssu
re (
mb
ar) 0.6 μm
1.2 μm
5 μm
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Pleat-HP/AQF116_EN_V1.4
Filtration Media PolypropyleneEnd Caps Polypropylene
Material Specifications
Recommended Operating Conditions
Max. Continuous Temperature 60°C (140°F)
Steam Sterilisation Can be repeatedly stem sterilised or autoclaved at up to 130°C
Max. Forward Differential Pressure 4 bar at 25°C
Dimensions
Outside Diameter 2.7" (68 mm)
Material Specification Micron End Fiting Part Number
DOE CFYGYT9410
CODE 7 CFYGYT9450
CODE 3 CFYGYT9440
DOE CFYKYT9410
CODE 7 CFYKYT9451
CODE 3 CFYKYT9440
DOE CFYOYT9410
CODE 7 CFYOYT9450
CODE 3 CFYOYT9440
CODE 9 CFYOYT300682
10 CODE 9 CFYTYT300683
25 CODE 9 CFZDYT300684
40 CODE 9 CFZFYT300685
DOE CFYGZD9410
CODE 7 CFYGZD9450
CODE 3 CFYGZD9440
DOE CFYKZD9410
CODE 7 CFYKZD9450
CODE 3 CFYKZD9440
DOE CFYOZD9410
CODE 7 CFYOZD9450
CODE 3 CFYOZD9440
CODE 9 CFYOZD300686
10 CODE 9 CFYTZD300687
25 CODE 9 CFZDZD300688
40 CODE 9 CFZFZD300689
DOE CFYGZE9410
CODE 7 CFYGZE9450
CODE 3 CFYGZE9440
DOE CFYKZE9410
CODE 7 CFYKZE9450
CODE 3 CFYKZE9440
DOE CFYOZE9410
CODE 7 CFYOZE9451
CODE 3 CFYOZE9440
0.6
1.2
5
30"
0.6
1.2
0.6
1.2
5
10"
5
20"
FILOTM Pleat-HPSpecifications
Ordering Information
FILOTM SpunCartridge Filters
Features & Benefits
• High flow ratesLow pressure lossHigh dirt holding capacityLong lifeFast rinse up to 18 MΩSeveral lengths available:9" 3/4 ; 20" ; 30" ; 40"FDA approved
••
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
High Purity Water
•
The FILOTM Spun cartridge filters
are a range of nominal rated
depth liquid filters (polypropylene).
Rating from 1 to 50 μm. •
•
•
•
Applications
Performance
0 20
Diff
eren
tia
l Pre
ssu
re (
mb
ar)
Flow Rate (l/min) for Liquid at 20°C
100
75
50
25
0
1 μm
5 μm
10 μm
20 μm
50 μm
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Spun/AQF117_EN_V1.2
Filtration Media PolypropyleneEnd Caps Polypropylene
FILOTM SpunSpecifications
Ordering Information
Material Specifications
Recommended Operating Conditions
Max. Temperature 65°C (150°F)
Max. Recommended Differential Pressure 2 bar (30 psid)
Max. Differential Pressure 4 bar @ 20°C (68°F)
Dimensions
Outside Diameter 2.5"Inside Diameter 1.1"
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
9" 3/4
1 DOE CFYKYS9300
30"
1 DOE CFYKZE9300
CODE 8 CFYKYS9370 CODE 8 CFYKZE9370 CODE 3 CFYKYS9341 CODE 3 CFYKZE9341
5 DOE CFYOYS9300
5 DOE CFYOZE9300
CODE 8 CFYOYS9370 CODE 8 CFYOZE9370 CODE 3 CFYOYS9341 CODE 3 CFYOZE9342
10 DOE CFYTYS9300
10 DOE CFYTZE9301
CODE 8 CFYTYS9370 CODE 8 CFYTZE9370 CODE 3 CFYTYS9341 CODE 3 CFYTZE9341
20 DOE CFZDYS9300
20 DOE CFZDZE9300
CODE 8 CFZDYS9370 CODE 8 CFZDZE9370 CODE 3 CFZDYS9341 CODE 3 CFZDZE9340
50 DOE CFZGYS9300 50 DOE CFZGZE9300
40"
1 DOE CFYKZF9300
CODE 8 CFYKZF9370 CODE 3 CFYKZF9341
5 DOE CFYOZF9300
20"
1 DOE CFYKZD9300 CODE 8 CFYOZF9370
CODE 8 CFYKZD9370 CODE 3 CFYOZF9341 CODE 3 CFYKZD9341
10 DOE CFYTZF9300
5 DOE CFYOZD9300 CODE 8 CFYTZF9370
CODE 8 CFYOZD9370 CODE 3 CFYTZF9341 CODE 3 CFYOZD9341
20 DOE CFZDZF9300
10 DOE CFYTZD9300 CODE 8 CFZDZF9370
CODE 8 CFYTZD9370 CODE 3 CFZDZF9340 CODE 3 CFYTZD9341 50 DOE CFZGZF9300
20 DOE CFZDZD9300
50"
1 DOE CFYKZG9300 CODE 8 CFZDZD9370 5 DOE CFYOZG9300 CODE 3 CFZDZD9340 20 DOE CFZDZG9300
50 DOE CFZGZD9300 50 DOE CFZGZG9300
FILOTM Spun-HPCartridge Filters
Features & Benefits
• High flow ratesLow pressure lossHigh dirt holding capacityLong lifeFast rinse up to 18 MΩSeveral lengths available:9" 3/4 ; 20" ; 30" ; 40"FDA approved
••
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
High Purity Water
•
The FILOTM Spun-HP cartridge
filters are a range of absolute
rated depth liquid filters
(polypropylene).
Absolute rating from 1 to 20 μm.•
•
•
•
Applications
400
300
200
100
0
7
6
5
4
3
2
1
0
0 8 16
Diff
eren
tia
l Pre
ssu
re (
psi
d)
Flow Rate (l/min) for Liquid at 20°C
Performance
Diff
eren
tia
l Pre
ssu
re (
mb
ar)
1 μm
5 μm
10 μm
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Spun-HP/AQF118_EN_V1.3
Filtration Media PolypropyleneEnd Caps Polypropylene
FILOTM Spun HPSpecifications
Ordering Information
Material Specifications
Recommended Operating Conditions
Max. Temperature 65°C (150°F)
Max. Recommended Differential Pressure 2 bar (30 psid)
Cleaning and Sterilisation
Max. Differential Pressure 4 bar @ 20°C (68°F)
FILOTM Spun-HP can be repeatedly (up to 25 times) steam sterilised in situ or autoclaved up to 130°C (266°F). FILOTM Spun-HP filters can be sanitised with hot water at up to 90°C (400 hours in 20 minutes
cycles) and are compatible with a wide range of chemicals.
Dimensions
Outside Diameter 2.5"Inside Diameter 1.1"
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYFYS9310 DOE CFYFZE9310
CODE 3 CFYFYS9340 CODE 3 CFYFZE9340
CODE 7 CFYFYS9350 CODE 7 CFYFZE9350
DOE CFYKYS9310 DOE CFYKZE9310
CODE 3 CFYKYS9340 CODE 3 CFYKZE9340
CODE 7 CFYKYS9350 CODE 7 CFYKZE9350
DOE CFYOYS9310 DOE CFYOZE9310
CODE 3 CFYOYS9340 CODE 3 CFYOZE9341
CODE 7 CFYOYS9350 CODE 7 CFYOZE9350
DOE CFYTYS9310 DOE CFYTZE9310
CODE 3 CFYTYS9340 CODE 3 CFYTZE9340
CODE 7 CFYTYS9350 CODE 7 CFYTZE9350
DOE CFZDYS9310
CODE 3 CFZDYS9340
CODE 7 CFZDYS9350
DOE CFYFZD9310 DOE CFYFZF9310
CODE 3 CFYFZD9340 CODE 3 CFYFZF9340
CODE 7 CFYFZD9350 CODE 7 CFYFZF9350
DOE CFYKZD9310 DOE CFYKZF9310
CODE 3 CFYKZD9340 CODE 3 CFYKZF9340
CODE 7 CFYKZD9350 CODE 7 CFYKZF9350
DOE CFYOZD9310 DOE CFYOZF9310
CODE 3 CFYOZD9340 CODE 3 CFYOZF9340
CODE 7 CFYOZD9350 CODE 7 CFYOZF9350
DOE CFYTZD9310 DOE CFYTZF9310
CODE 3 CFYTZD9340 CODE 3 CFYTZF9340
CODE 7 CFYTZD9350 CODE 7 CFYTZF9350
40"
0.5
1
5
10
30"
0.5
1
5
10
20"
0.5
1
5
10
9" 3/4
0.5
1
5
10
20
FILOTM MemCartridge Filters
Features & Benefits
• High flow ratesHydrophilic PES membraneValidated membraneIntegrity testableFull traceability
••
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Sterile FiltrationHigh Purity Water
•
The FILOTM Mem constitutes a
range of pleated membrane
cartridge filters for microbial
reduction for pharmaceutical
and electronic applications.•
•
•
Quality
• Manufactured in a controlled environmentManufactured in accordance with GMP100% flushed with purified water100% integrity testedMaterials meet 21CFR part 177 and USP class VI requirementsFull validation guide available
•
•
•
•
•
•
Applications
100
0 10 l/min 20 l/min
50
Typical initial clean media differential pressure
per 250 mm (10") cartridge for water at 20°C, 1 cp
1
Performance
Diff
eren
tia
l Pre
ssu
re (
mb
ar)
Diff
eren
tia
l Pre
ssu
re (
psi
d)
0.2
μm
0.45 μ
m
0.1
μm
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Mem/AQF119_EN_V1.3
Filtration Media Polyethersulphone
Support Polyester
Cage and Core Polypropylene
O-ring Seal Silicone
End Cap Nylon
Reinforcing Ring Stainless Steel
FILOTM MemSpecifications
Ordering Information
Material Specifications
Recommended Operating Conditions
Max. Continuous Operating Temperature 60°C (140°F)
Cleaning and Sanitisation
Max. Differential Pressure (forward) 4.0 bard (60 psid) @ 40°C (104°F) ; 1.7 bard (25 psid) @ 90°C (194°F)
FILOTM Mem cartridge can be autoclaved up to 10 times up to 130°C or steam sterilised up to 130°C
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYCYT9410 DOE CFYBYT9410
CODE 3 CFYCYT9440 CODE 3 CFYBYT9440
CODE 7 CFYCYT9451 CODE 7 CFYBYT9450
CODE 9 CFYCYT9460 DOE CFYCYT9411
DOE CFYEYT9410 CODE 3 CFYCYT9441
CODE 3 CFYEYT9440 CODE 7 CFYCYT9452
CODE 7 CFYEYT9450
CODE 9 CFYEYT9460 DOE CFYBZD9410
CODE 3 CFYBZD9444
DOE CFYCZD9410 CODE 7 CFYBZD9450
CODE 3 CFYCZD9440 DOE CFYCZD9411
CODE 7 CFYCZD9451 CODE 3 CFYCZD9441
CODE 9 CFYCZD9460 CODE 7 CFYCZD9452
DOE CFYEZD9410
CODE 3 CFYEZD9440
0.1
DOE CFYBZE9410
CODE 7 CFYEZD9450 CODE 3 CFYBZE9440
CODE 9 CFYEZD9460 CODE 7 CFYBZE9450
DOE CFYCZE9411
DOE CFYCZE9410 CODE 3 CFYCZE9441
CODE 3 CFYCZE9440 CODE 7 CFYCZE9451
CODE 7 CFYCZE9450
CODE 9 CFYCZE9460
DOE CFYEZE9411
CODE 3 CFYEZE9440
CODE 7 CFYEZE9450
CODE 9 CFYEZE9460
0.1
20"
30"
10"
0.2
0.2
0.1
0.2
0.2
30"
0.45
0.45
0.45
0.2
10"
0.2
20"
FILOTM Mem-P (Pharmaceutical applications) FILOTM Mem-E (Electronic applications)
Integrity Test Minimum bubble point: 49 psig (3.4 bar)Diffusional flow in water per 10": 16 cc/min at 41 psig (2.8 bar)
RO MembranesVWSRO-XTLE-2521Extra Low Energy Element
Part NumberNominal Area
m²Permeate Flow Rate
m3/d (usgpd)Minimum Salt Rejection
(%)
MBROYL0700 1.1 1.2 (320) 98
TypeConfiguration: Spiral WoundMembrane Polymer: Composite Polyamide/Polysulphone
Test Conditions500 ppm NaCl solution, 7 bar (100 psi), 25°C, pH 6 – 7, Permeate Recovery 10%.
Operating Limits*Maximum Applied Pressure: 21 bar (300 psig)Maximum Free Chlorine Concentration: < 0.1 ppmMaximum Operating Temperature: 45°CFeedwater pH Range: 3.0 – 10.0Maximum Feedwater Turbidity: 1.0 NTUMaximum Feedwater Fouling Index (SDI): 5Maximum Element Recovery: 20%Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained by the application of this information or the safety or suitability of our products, either alone or in combination with other products. Users are advised to make their own tests to determine the safety and suitability of each product combination for their own purposes.
A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYL0700 1.4 (6) 21 (533) 2.4 (61) 0.75 (19.1) 0.9 (2) 1.2 (30.5)
Maximum Feed Flowm3/hr (usgpm)
Dimensions inches (mm) Weight. kg (lbs)
Permeate tube lengthinches (mm)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-XTLE-2521/AQF106_EN_V1.2 nov10
RO MembranesVWSRO-XTLE-4021Extra Low Energy Element
Part NumberNominal Area
m²Permeate Flow Rate
m3/d (usgpd)Minimum Salt Rejection
(%)
MBROYN0700 3 3.6 (960) 98
TypeConfiguration: Spiral WoundMembrane Polymer: Composite Polyamide/Polysulphone
Test Conditions500 ppm NaCl solution, 7 bar (100 psi), 25°C, pH 6 – 7, Permeate Recovery 10%.
Operating Limits*Maximum Applied Pressure: 21 bar (300 psig)Maximum Free Chlorine Concentration: < 0.1 ppmMaximum Operating Temperature: 45°CFeedwater pH Range: 3.0 – 10.0Maximum Feedwater Turbidity: 1.0 NTUMaximum Feedwater Fouling Index (SDI): 5Maximum Element Recovery: 20%Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained by the application of this information or the safety or suitability of our products, either alone or in combination with other products. Users are advised to make their own tests to determine the safety and suitability of each product combination for their own purposes.
A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYN0700 2.7 (12) 21 (533) 3.95 (100) 0.75 (19.1) 1.8 (4) 1.2 (30.5)
Maximum Feed Flowm3/hr (usgpm)
Dimensions inches (mm) Weight. kg (lbs)
Permeate tube lengthinches (mm)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-XTLE-4021/AQF105_EN_V1.2 nov10
RO MembranesVWSRO-XTLE-4040Extra Low Energy Element
Part Number
MBROYN0704 7.9 9.5 (2500) 99 99.2
Nominal Aream²
Permeate Flow Ratem3/d (usgpd)
Salt Rejection (%)
Minimum Nominal
TypeConfiguration: Spiral WoundMembrane Polymer: Composite Polyamide/Polysulphone
Test Conditions500 ppm NaCl solution, 7 bar (100 psi), 25°C, pH 6 – 7, Permeate Recovery 15%.
Operating Limits*Maximum Applied Pressure: 42 bar (600 psig)Maximum Free Chlorine Concentration: < 0.1 ppmMaximum Operating Temperature: 45°CFeedwater pH Range: 3.0 – 10.0Maximum Feedwater Turbidity: 1.0 NTUMaximum Feedwater Fouling Index (SDI): 5Maximum Element Recovery: 20%Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained by the application of this information or the safety or suitability of our products, either alone or in combination with other products. Users are advised to make their own tests to determine the safety and suitability of each product combination for their own purposes.
A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYN0704 3.6 (16) 40 (1016) 3.95 (100) 0.75 (19.1) 3.6 (8) 1.05 (26.7)
Maximum Feed Flowm3/hr (usgpm)
Dimensions inches (mm) Weight. kg (lbs)
Permeate tube lengthinches (mm)
A B C
Visit our website:www.veoliawaterst.com
VWS CATALOGUE /VWSRO-XTLE-4040/AQF104_EN_V1.3 sept11
RO MembranesVWSRO-LERA-8040Low Energy Regular Area Element
Part Number
MBROYR0750 37 45.4 (12000) 99.0 99.3
Nominal Aream²
Permeate Flow Ratem3/d (usgpd)
Salt Rejection (%)
Minimum Nominal
TypeConfiguration: Spiral WoundMembrane Polymer: Composite Polyamide/Polysulphone
Test Conditions1500 ppm NaCl solution, 10.5 bar (150 psi), 25°C, pH 6 – 7, Permeate Recovery 15%.
Operating Limits*Maximum Applied Pressure: 42 bar (600 psig)Maximum Free Chlorine Concentration: < 0.1 ppmMaximum Operating Temperature: 45°CFeedwater pH Range: 3.0 – 10.0Maximum Feedwater Turbidity: 1.0 NTUMaximum Feedwater Fouling Index (SDI): 5Maximum Element Recovery: 20%Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained by the application of this information or the safety or suitability of our products, either alone or in combination with other products. Users are advised to make their own tests to determine the safety and suitability of each product combination for their own purposes.
A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYR0750 17 (75) 40 (1016) 7.89 (200) 1.125 (28.6) 16.4 (36)
Maximum Feed Flowm3/hr (usgpm)
Dimensions inches (mm) Weight. kg (lbs)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-LERA-8040/AQF110_EN_V1.2 nov10
RO MembranesVWSRO-SRHA-8040Standard Rejection High Area Element
Part Number
MBROYR0754 41 45.4 (12000) 99.5 99.6
Nominal Aream²
Permeate Flow Ratem3/d (usgpd)
Salt Rejection (%)
Minimum Nominal
TypeConfiguration: Spiral WoundMembrane Polymer: Composite Polyamide/Polysulphone
Test Conditions1500 ppm NaCl solution, 10.5 bar (150 psi), 25°C, pH 6 – 7, Permeate Recovery 15%.
Operating Limits*Maximum Applied Pressure: 42 bar (600 psig)Maximum Free Chlorine Concentration: < 0.1 ppmMaximum Operating Temperature: 45°CFeedwater pH Range: 3.0 – 10.0Maximum Feedwater Turbidity: 1.0 NTUMaximum Feedwater Fouling Index (SDI): 5Maximum Element Recovery: 20%Maximum Pressure Drop Per Element: 0.7 bar (10 psi)
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained by the application of this information or the safety or suitability of our products, either alone or in combination with other products. Users are advised to make their own tests to determine the safety and suitability of each product combination for their own purposes.
A
B
C
Feed
Concentrate
Permeate
Part Number
MBROYR0754 17 (75) 40 (1016) 7.89 (200) 1.125 (28.6) 16.4 (36)
Maximum Feed Flowm3/hr (usgpm)
Dimensions inches (mm) Weight. kg (lbs)
A B C
Visit our website:
www.veoliawaterst.com
VWS CATALOGUE /VWSRO-SRHA-8040/AQF112_EN_V1.2 nov10
Pressure GaugesRadial or Bottom ConnectionStainless SteelWith Liquid Filling
Features & Benefits
• Excellent load-cycle stability and shock resistanceAll stainless steel constructionGerman Lloyd, Gosstandart and DVGW approval
PART REF. IMPSGG0030
Hygienic/ sanitary type diaphragmtype pressureConnection 1.5" Tri-clamp
PART REF. IMPSGG1315
Liquid, glycerine filled ; Dampens out vibrations out which can occurEase of reading the pressureIncreased gauge life
PART REF. IMPSGG1360
Liquid, glycerine filled ; Dampens out vibrations out which can occurEase of reading the pressureIncreased gauge life
•
•
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
With liquid-filled case for applications with high dynamic pressure pulsationsor vibrations
•
The measurement of pressure
using Bourdon tube type
pressure gauges is important for
monitoring the operation of
water treatment solutions and
also assists with the prediction
of the maintenance requirements.
Scale ranges from 0 to 11 bar
depending the models:
• PART REF. IMPSGG0030 from 0 to 7 bar
• PART REF. IMPSGG1315 from 0 to 6.8 bar from 0 to 100 psi
• PART REF. IMPSGG1360 from 0 to 11 bar from 0 to 160 psi
•
•
•
•
•
Applications
•
•
•
VWS Monitor Free Chlorine, Total Chlorine, Hardness, Carbonate Hardness
Features & Benefits
• Menu-driven, programmable functions in clear LCD text displayProgrammable hardness unit in °dH, °f, ppm CaCO
3, mmol/l
Accurate titration via piston-dosing pumpLow maintenance operationLow reagent and water consumptionTwo adjustable limit values withprogrammable switch functionsMonitoring of two measuring points Analysis initiation: Automatic time set intervals (0 - 99 minutes) Dependent on the residual plant capacity Quantity-dependent (water meter) External controlProgrammable supplementary programOutput terminal for alarm (fault messages) Monitoring of an analysis run and error messages Monitoring of the filter capacityReagent storage bottle 500ml for extended operating periodsAnalog terminal 0/4-20mAAvailable in 3 languages
•
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Boiler feed waterProcess waterPharmaceuticalsFood & beverageDialysisSwimming pool waterDrinking water•
The VWS Monitor
is the ideal system for water
quality monitoring.
Several models and parameters:
Free chlorine (CLF)Total chlorine (CLT)Hardness (TH)Hardness & Chlorine (THCL)Carbonate hardness (KH)
•
•
•
•
•
•
•
••
•
Ideal for monitoring water quality:
• •
•
•
•
•
•
•
••
•
Applications
••
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /VWS Monitor/AQF122_EN_V1.1
VWS MonitorPerformance
Ordering Information
Specifications
Parameter Reagent type °dH °f ppm CaCO3 mmol/l mg/l - ppmCL 2250 ACL 2250 B 0 - 2.50CL 2250 CCL 2250 A 0 - 2.50CL 2250 B
Water hardness TH 2005 0.05 - 0.50 0.09 - 0.89 0.89 - 8.95 0.01 - 0.09Water hardness TH 2025 0.25 - 2.50 0.45 - 4.48 4.47 - 44.7 0.04 - 0.45Water hardness TH 2100 1.0 - 10.0 1.79 - 17,9 17.9 - 179 0.18 - 1.79Water hardness TH 2250 2.5 - 25.0 4.48 - 44.8 44.8 - 448 0.45 - 4.48
Carbonate hardness TC 2050 0.5 -5.0 0.90 - 8.96 0.18 - 1.79Carbonate hardness TC 2100 1.0 - 20.0 1.79 - 35.8 0.36 - 7.16
Total chlorine
Free chlorine
Total ChlorineCarbonate Hardness + Hardness
Hardness + Total Chlorine
Part NumberIEPOHR301087
IEPOGU301092
IEPOGU301091
IEPOGU301089
IEPOGU301090
ModelVWS Monitor KHVWS Monitor CLFVWS Monitor CLT
VWS Monitor DUOVWS Monitor THCL
Measuring ParameterCarbonate Hardness
Free Chlorine
Power supplyPower consumption
Degree of protectionProtection class
Ambient temperatureWater temperatureOperating pressure
Dimensions (W x H x D)Weight
230 V or 24 V ± 10 % ; 50 - 60 Hzmax. 30 VA
IP 65I ; CE
10 - 45 °C10 - 40 °C
0.1 - 8 bar ; 104 - 8 x 105 Pa380 x 480 x 280 mm
approx. 10.5 kg
VWS Monitor THHardness
Features & Benefits
• Menu-driven, programmable functions in clear LCD text displayProgrammable hardness unit in °dH, °f, ppm CaCO
3, mmol/l
Accurate titration via piston-dosing pumpLow maintenance operationLow reagent and water consumptionTwo adjustable limit values withprogrammable switch functions Analysis initiation: Automatic time set intervals (0 - 99 minutes) Quantity-dependent (water meter) External analysis STOPOutput terminal for alarm (fault messages) Monitoring of an analysis run and error messages Reagent storage bottle 500ml for extended operating periodsAnalog terminal 0/4-20mAAvailable in 6 languages
•
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
operation of installed plant.
Boiler feed waterProcess waterPharmaceuticalsFood & beverageDialysisSwimming pool waterDrinking water•
The VWS Monitor TH
automatically determines
residual / total water hardness
via titration.
Measuring range: 0.05 -25.0°dH•
•
•
•
•
•
•
••
•
Ideal for monitoring water quality:
• •
•
•
•
•
•
Applications
•
•
Visit our website:www.veoliawaterst.com
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /VWS Monitor/AQF121_EN_V1.1
VWS Monitor THPerformance
Ordering Information
Specifications
Parameter Reagent type °dH °f ppm CaCO3 mmol/l mg/l - ppmWater hardness TH 2005 0.05 - 0.50 0.09 - 0.89 0.89 - 8.95 0.01 - 0.09Water hardness TH 2025 0.25 - 2.50 0.45 - 4.48 4.47 - 44.7 0.04 - 0.45Water hardness TH 2100 1.0 - 10.0 1.79 - 17,9 17.9 - 179 0.18 - 1.79Water hardness TH 2250 2.5 - 25.0 4.48 - 44.8 44.8 - 448 0.45 - 4.48
Measuring parameterHardness
ModelVWS Monitor TH
Part NumberIEPOHR301088
Power supplyPower consumption
Degree of protectionProtection class
Ambient temperatureWater temperatureOperating pressure
Dimensions (W x H x D)Weight
230 V or 24 V ± 10 % ; 50 - 60 Hzmax. 30 VA
IP 65I ; CE
10 - 45 °C10 - 40 °C
0.1 - 8 bar ; 104 - 8 x 105 Pa380 x 480 x 280 mm
approx. 10.5 kg
www.veoliawaterst.comwww.veoliawaterst.com