STANDARD BSP EFA CABLES Rev. 0 (July 2013)

description

bsp cable

Transcript of Standard BSP EFA Cables_Rev0.1

STANDARD BSP EFA CABLESRev. 0 (July 2013)

Indoor, Instrument Signal Cables, Non-IS (items 1, 2, 3, 4)……………………………………………..……………………...………….Page 3

Indoor, Instrument Signal Cables, IS (items 5, 6, 7, 8)…………………………………………………...…...……………………..……….Page 5

Outdoor, Instrument Signal Cables, Non-IS (items 9, 10, 11, 12)……………………………….…..……………………...…………….Page 7

Outdoor, Instrument Signal Cables, IS (items 13, 14, 15, 16)………………………………………...…………………………..……….Page 9

Indoor, Fire Resistant Cables, Non-IS (items 17, 18, 19)…………………………………………………..……..…………………….……….Page 11

Outdoor, Fire Resistant Cables, Non-IS (items 20, 21, 22, 23)…………………………………………..…………………………..……….Page 12

Outdoor, Instrument Signal Cables, Non-IS, with individual and overall Shield (items 24, 25, 26, 27)…….…………...…Page 14

Outdoor, Instrument Signal Cables, with Ind and overall Shield, IS (items 28, 29, 30, 31)……..…..……………………...…Page 16

Fire Resistant Power Cables (items 32, 33, 34)…………………………………………………………………......…..……………….………Page 18

Instrument Standard Power Cables (items 35, 36, 37, 38)………………………………………………….......……………….………….Page 20

Fieldbus Cables (items 39, 40, 41)……………………………………………………………….………………………...……………….……………Page 22

Fiber Optic Cables (items 42, 43, 44)……………………………………………………………….…………………...……………..……………Page 23

Contents

Rev. 0 (July-2013) Page 2 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

1 1001694864 Indoor, Instrument Signal, Non-IS, 1 Pair, 0.5mm², Black

Fire spec non armoured electrical cable

Application NON IS INSTRUMENT SIGNAL, SINGLE PAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS,OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 1 PAIR, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 7.00 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

2 1001694865 Indoor, Instrument Signal, Non-IS, 2 Pairs, 0.5mm², Black

Fire spec non armoured electrical cable

Application NON IS INSTRUMENT SIGNAL, MULTIPAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 2 PAIRS, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 7.90 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

Rev. 0 (July-2013) Page 3 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

3 1001694866 Indoor, Instrument Signal, Non-IS, 10 Pairs, 0.5mm², Black

Fire spec non armoured electrical cable

Application NON IS INSTRUMENT SIGNAL, MULTIPAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 10 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 17.2 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

4 1001694867 Indoor, Instrument Signal, Non-IS, 20 Pairs, 0.5mm², Black

Fire spec non armoured electrical cable

Application NON IS INSTRUMENT SIGNAL, MULTIPAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 20 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 22.3 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

Rev. 0 (July-2013) Page 4 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

5 1001694868 Indoor, Instrument Signal, IS, 1 Pair, 0.5mm², Blue

Fire spec non armoured electrical cable

Application IS, INSTRUMENT SIGNAL, SINGLE PAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 1 PAIR, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 7.00 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

6 1001694869 Indoor, Instrument Signal, IS, 2 Pairs, 0.5mm², Blue

Fire spec non armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 2 PAIRS, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 7.90 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

Rev. 0 (July-2013) Page 5 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

7 1001694870 Indoor, Instrument Signal, IS, 10 Pairs, 0.5mm², Blue

Fire spec non armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 10 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 17.2 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

8 1001694871 Indoor, Instrument Signal, IS, 20 Pairs, 0.5mm², Blue

Fire spec non armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, INDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, OS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 20 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 22.3 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

Rev. 0 (July-2013) Page 6 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

9 1001694872 Outdoor, Instrument Signal, Non-IS, 1 Pair, 0.5mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, SINGLEPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 1 PAIR, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 11.4 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

10 1001694873 Outdoor, Instrument Signal, Non-IS, 2 Pairs, 0.5mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 2 PAIRS, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 12.3 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 7 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

11 1001694874 Outdoor, Instrument Signal, Non-IS, 10 Pairs, 0.5mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 10 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 22.9 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

12 1001694875 Outdoor, Instrument Signal, Non-IS, 20 Pairs, 0.5mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 20 PAIRS,CONDUCTOR SIZE :16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, od, overall (mm) 29.1 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 8 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

13 1001694876 Outdoor, Instrument Signal, IS, 1 Pair, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, SINGLEPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 1 PAIR, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 11.4 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

14 1001708906 Outdoor, Instrument Signal, IS, 2 Pairs, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 2 PAIRS, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 12.3 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 9 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

15 1001694878 Outdoor, Instrument Signal, IS, 10 Pairs, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 10 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 22.9 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

16 1001694879 Outdoor, Instrument Signal, IS, 20 Pairs, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 20 PAIRS,CONDUCTOR SIZE :16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) 29.1 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 10 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

17 1001694860 Indoor, Fire Resistant Cable, Non-IS, 2 Cores, 1.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT SIGNAL, MULTI CORE, INDOOR

Flammability properties FIRE RESISTANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction FRI, XLPE, MS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Number, cores 2 CORES

Core Colour Identifications AS PER BS EN50288-7, WHITE WITH NUMBERS

Cross section, cores (mm2) 1.5 SQ. MM.

Diameter, OD, overall (mm) 11 MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

18 1001694841 Indoor, Fire Resistant Cable, Non-IS, 4 Cores, 1.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT SIGNAL, MULTI CORE, INDOOR

Flammability properties FIRE RESISTANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction FRI, XLPE, MS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Number, cores 4 CORES

Core Colour Identifications AS PER BS EN50288-7, WHITE WITH NUMBERS

Cross section, cores (mm2) 1.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

Rev. 0 (July-2013) Page 11 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

19 1001694842 Indoor, Fire Resistant Cable, Non-IS, 10 Cores, 1.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT SIGNAL, MULTI CORE, INDOOR

Flammability properties FIRE RESISTANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction FRI, XLPE, MS, FR-LSZH

Mat, conductor wire ANNEALED COPPER WIRE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, outer sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Colour, outer sheath BLACK

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Number, cores 10 CORES

Core Colour Identifications AS PER BS EN50288-7, WHITE WITH NUMBERS

Cross section, cores (mm2) 1.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec non armoured electrical cable CBL ELEC N-ARM FIRE

20 1001694843 Outdoor, Fire Resistant Cable, Non-IS, 2 Cores, 1.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT SIGNAL, MULTI CORE, OUTDOOR

Flammability properties FIRE RESISTANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction FRI, XLPE, MS, FR-LSZH, SWA, FR-LSZH - UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, cores 2 CORES

Core Colour Identifications AS PER BS EN50288-7, WHITE WITH NUMBERS

Cross section, cores (mm2) 1.5 SQ. MM.

Diameter, od, overall (mm) 14.0 MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 12 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

21 1001694844 Outdoor, Fire Resistant Cable, Non-IS, 4 Cores, 1.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT SIGNAL, MULTI CORE, OUTDOOR

Flammability properties FIRE RESISTANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction FRI, XLPE, MS, FR-LSZH, SWA, FR-LSZH - UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, cores 4 CORES

Core Colour Identifications AS PER BS EN50288-7, WHITE WITH NUMBERS

Cross section, cores (mm2) 1.5 SQ. MM.

Diameter, od, overall (mm) 16.0 mm, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

22 1001694845 Outdoor, Fire Resistant Cable, Non-IS, 10 Cores, 1.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT SIGNAL, MULTI CORE, OUTDOOR

Flammability properties FIRE RESISTANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction FRI, XLPE, MS, FR-LSZH, SWA, FR-LSZH - UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, cores 10 CORES

Core Colour Identifications AS PER BS EN50288-7, WHITE WITH NUMBERS

Cross section, cores (mm2) 1.5 SQ. MM.

Diameter, od, overall (mm) 19.8 mm, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 13 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

23 1001694846 Outdoor, Fire Resistant Cable, Non-IS, 20 Cores, 1.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT SIGNAL, MULTI CORE, OUTDOOR

Flammability properties FIRE RESISTANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction FRI, XLPE, MS, FR-LSZH, SWA, FR-LSZH - UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Screening OVERALL SCREEN ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, cores 20 CORES

Core Colour Identifications AS PER BS EN50288-7, WHITE WITH NUMBERS

Cross section, cores (mm2) 1.5 SQ. MM.

Diameter, od, overall (mm) XX mm, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

24 1001694847 Outdoor, Instrument Signal, Non-IS, with Ind and overall Shield, 1 Pair, 0.5mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, SINGLEPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 1 PAIR, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 14 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

25 1001694848 Outdoor, Instrument Signal, Non-IS, with Ind and overall Shield, 2 Pairs, 0.5mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 2 PAIRS, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

26 1001694850 Outdoor, Instrument Signal, Non-IS, with Ind and overall Shield, 10 Pairs, 0.5mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 10 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 15 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

27 1001694849 Outdoor, Instrument Signal, Non-IS, with Ind and overall Shield, 20 Pairs, 0.5 mm², Black

Fire spec armoured electrical cable

Application NON IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 20 PAIRS,CONDUCTOR SIZE :16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, od, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

28 1001694851 Outdoor, Instrument Signal, with Ind and overall Shield, IS, 1 Pair, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, SINGLEPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 1 PAIR, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 16 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

29 1001694852 Outdoor, Instrument Signal, with Ind and overall Shield, IS, 2 Pairs, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 2 PAIRS, CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

30 1001694853 Outdoor, Instrument Signal, with Ind and overall Shield, IS, 10 Pairs, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 10 PAIRS,CONDUCTOR SIZE: 16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 17 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

31 1001694854 Outdoor, Instrument Signal, with Ind and overall Shield, IS, 20 Pairs, 0.5mm², Blue

Fire spec armoured electrical cable

Application IS, INSTRUMENT SIGNAL, MULTIPAIR, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec BS EN 50288-7 IEC 60754 & 61034 - LSZH

Construction XLPE, IS, MS, FR-LSZH, OS, SWA, FR-LSZH-UV Resistant

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLUE, INTRINSICALLY SAFE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 20 PAIRS,CONDUCTOR SIZE :16/0.2

Pair Colour Identifications AS PER BS EN50288-7, BLACK AND WHITE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER EN50288-7.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

32 1001694855 Fire Resistant Power Cable, 2 Cores, 2.5mm², Black

Fire spec armoured electrical cable

Application FIRE RESISTANT POWER, MULTICORE, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 600V/1000V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1 IEC 60754 & 61034 - LSZH

Construction FRI/XLPE/FRLSZH/SWB/FRLSZH/UV RESISTANT

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE BRAIDED

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANT

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Number, Cores 2 CORES ,CONDUCTOR SIZE :XX

Core Colour Identifications BROWN AND BLUE WITH NUMBERS EMBOSSED FOR EACH CORE.

Cross section, cores(mm2) 2.5 SQ. MM.

Diameter, OD, overall (mm) 15.5 MM, TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 18 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

33 1001694856 Fire Resistant Power Cable, 4 Cores, 2.5mm², Black

Fire spec armoured electrical cable

Application Fire Resistant Power Cable OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 600/1000 V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1 IEC 60754 & 61034 - LSZH

Construction FRI/XLPE/FRLSZH/SWB/FRLSZH/UV-RESISTANT

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE BRAIDED

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Number, Cores 4 CORES,CONDUCTOR SIZE :16/0.2

Core Colour Identifications BROWN, BLACK, GREY AND BLUE WITH NUMBERS EMBOSSED FOR EACH CORE.

Cross section, cores(mm2) 2.5 SQ. MM.

Diameter, OD, overall (mm) 17 MM, TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

34 1001708908 Fire Resistant Power Cable, 12 Cores, 2.5mm², Black

Fire spec armoured electrical cable

Application Fire Resistant Power Cable OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 600/1000 V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1 IEC 60754 & 61034 - LSZH

Construction FRI/XLPE/FRLSZH/SWB/FRLSZH/UV RESISTANT

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Design spec, conductor GLASS MICA TAPE APPLIED OVER CONDUCTOR

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE BRAIDED

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Resistance, fire FIRE RESISTANT TO IEC 60331-21 and BS6387 Cat-C

Number, Cores 12 CORES, CONDUCTOR SIZE :16/0.2

Core Colour Identifications WHITE WITH NUMBERS EMBOSSED FOR EACHCORE.

Cross section, cores(mm2) 2.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 19 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

35 1001694857 Instrument Standard Power cable, 2 Cores, 2.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT POWER MULTICORE, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 600/1000 V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1 IEC 60754 & 61034 - LSZH

Construction XLPE/FRLSZH/SWB/FRLSZH-UV RESISTANCE

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE BRAIDED

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Cores 2 CORES, CONDUCTOR SIZE: 16/0.2

Core Colour Identifications BROWN AND BLUE WITH NUMBERS EMBOSSED FOR EACH CORE.

Cross section, cores(mm2) 2.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

36 1001694858 Instrument Standard Power cable, 4 Cores, 2.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT POWER MULTICORE, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage V 600/1000

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1 IEC 60754 & 61034 - LSZH

Construction XLPE/FRLSZH/SWB/FRLSZH-UV RESISTANCE

Mat, conductor wire PLAIN ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring BRAIDED GALVANISED STEEL WIRE

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Cores 4 CORES, CONDUCTOR SIZE: XX

Core Colour Identifications BROWN, BLACK, GREY AND BLUE WITH NUMBERS EMBOSSED FOR EACH CORE.

Cross section, cores(mm2) 2.5 SQ. MM.

Diameter, OD, overall (mm) 15 MM, TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 20 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

37 1001694859 Instrument Standard Power cable, 12 Cores, 2.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT POWER MULTICORE, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage V 600/1000

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1 IEC 60754 & 61034 - LSZH

Construction XLPE/FRLSZH/SWB/FRLSZH-UV RESISTANCE

Mat, conductor wire PLAIN ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE BRAIDED

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Cores 12 CORES CONDUCTOR SIZE: XX

Core Colour Identifications WHITE WITH NUMBERS EMBOSSED FOR EACHCORE.

Cross section, cores(mm2) 2.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

38 1001708907 Instrument Standard Power cable, 27 Cores, 2.5mm², Black

Fire spec armoured electrical cable

Application INSTRUMENT POWER MULTICORE, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 600/1000 V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1, IEC 60754 & 61034 - LSZH

Construction XLPE/FRLSZH/SWB/FRLSZH-UV RESISTANCE

Mat, conductor wire ANNEALED COPPER WIRE

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE BRAIDED

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Cores 27 CORES, CONDUCTOR SIZE: XX

Core Colour Identifications WHITE WITH NUMBERS EMBOSSED FOR EACHCORE.

Cross section, cores(mm2) 2.5 SQ. MM.

Diameter, OD, overall (mm) XX MM, TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 21 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

39 1001694921 Fieldbus, 1 Pair, 0.8mm², Black

Fieldbus cable per IEC 61558-2

Application H1 Fieldbus- TYPE A, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1, IEC 60754 & 61034 - LSZH

Construction XLPE/ IS/FRLSZH/OS/SWA/FRLSZH-UV RESISTANCE

Mat, conductor wire STRANDED BARE COPPER

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE ARMOUR

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 1 PAIR, CONDUCTOR SIZE: XX

Pair Colour Identifications AS PER BS IEC-60502-1, BLUE AND ORANGE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.8 SQ. MM.

Diameter, OD, overall (mm) TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Maximum conductor resistance 22 OHMS/KM

Impedance @ 31.25kHz 100 OHMS +/- 20%

Maximum attenuation @ 39kHz 3 DB/KM

Maximum Capacitive unbalance to shield 150 pF/KM

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Outer sheath to be marked with "FIELDBUS CABLE" label.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

40 1001694922 Fieldbus, 2 Pairs, 0.8mm², Black

Fieldbus cable per IEC 61558-2

Application H1 Fieldbus- TYPE A, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1, IEC 60754 & 61034 - LSZH

Construction XLPE/ IS/FRLSZH/OS/SWA/FRLSZH-UV RESISTANCE

Mat, conductor wire STRANDED BARE COPPER

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE ARMOUR

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 2 PAIRS, CONDUCTOR SIZE: XX

Pair Colour Identifications AS PER BS IEC-60502-1, BLUE AND ORANGE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.8 SQ. MM.

Diameter, OD, overall (mm) TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Maximum conductor resistance 22 OHMS/KM

Impedance @ 31.25kHz 100 OHMS +/- 20%

Maximum attenuation @ 39kHz 3 DB/KM

Maximum Capacitive unbalance to shield 150 pF/KM

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Outer sheath to be marked with "FIELDBUS CABLE" label.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

Rev. 0 (July-2013) Page 22 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

41 1001694923 Fieldbus, 10 Pairs, 0.8mm², Black

Fieldbus cable per IEC 61558-2

Application H1 Fieldbus- TYPE A, OUTDOOR

Flammability properties FLAME RETARDANT

Voltage 300 V

Max Operating Temp 90 DEGREE C

Design spec IEC-60502-1, IEC 60754 & 61034 - LSZH

Construction XLPE/ IS/FRLSZH/OS/SWA/FRLSZH-UV RESISTANCE

Mat, conductor wire STRANDED BARE COPPER

Mat spec, insulation CROSS-LINKED POLYETHYLENE

Mat spec, inner sheath FLAME RETARDANT -LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034

Armouring SINGLE LAYER OF GALVANISED STEEL WIRE ARMOUR

Mat spec, outer sheath FLAME RETARDANT - LOW SMOKE ZERO HALOGEN TO IEC 60754 & 61034, U.V RESISTANT

Colour, outer sheath BLACK, UV RESISTANCE

Screening INDIVIDUAL AND OVERALL SCREEN WITH ALUMUNIUM POLYESTER TAPE WITH TINNED COPPER DRAIN WIRE

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, Pairs 10 PAIRS, CONDUCTOR SIZE: XX

Pair Colour Identifications AS PER BS IEC-60502-1, BLUE AND ORANGE WITH NUMBERS EMBOSSED FOR EACH PAIR.

Cross section, cores(mm2) 0.8 SQ. MM.

Diameter, OD, overall (mm) TOLERANCE AS PER IEC-60502-1.

UV Resistant ACCORDING TO UL1581 – SECT 1200

Maximum conductor resistance 22 OHMS/KM

Impedance @ 31.25kHz 100 OHMS +/- 20%

Maximum attenuation @ 39kHz 3 DB/KM

Maximum Capacitive unbalance to shield 150 pF/KM

Marking on the external surface of the outer sheath OUTER SHEATH TO BE EMBOSSED WITH BS NUMBER, CABLE SIZE, TYPE (FLAME RETARDANT REDUCED

TOXICITY) AND MANUFACTURER'S NAME.

Cable drum shall have fixed weatherproof identification of the following: SAP NUMBER, MANUFACTURER'S NAME AND YEAR OF MANUFACTURE, ORDER AND

ITEM NUMBER, CABLE TYPE AND SIZE, VOLTAGE GRADE AND MARKING FOR DIRECTION OF LAY.

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Outer sheath to be marked with "FIELDBUS CABLE" label.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Fire spec armoured electrical cable CBL ELEC ARM FIRE

42 1001694861 Fiber Optic, 12 Cores, Single Mode, Black

Fiber Optic Cable

Application Ethernet / VoIP/ Data/ CCTV/ Instrument Signal, Multi core

Flammability properties Flame Retardant, Low Smoke Zero Halogen

Design spec IEC 60793, IEC 60794 Part 3, IEC 60754 & IEC 61034 - LSZH

Construction Strength member, Fiber, Loose tube, moisture barrier sheath, PE inner sheath, SWA, PE outer sheath

Mat spec, Central Strength member Fiber Glass

Core Cladding Material/ Filling PBT Loose Tubes/ Jelly Filled

Mat spec, inner sheath Polyethylene, LSZH

Mat spec, outer sheath PE, LSZH

Colour, outer sheath Black

Armouring Single Layer of Galvanised Steel Wire

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, cores 12 cores

UV Resistant According To UL1581 – Sect 1200

Optical Fibre Type : Single Mode

Max Attenuation 0.4 dB/km @ wavelength 1300nm

Core Diameter: 8.7± 0.5µm

Cladding Diameter for Each core: 125 ± 2 µm

Outer Diameter: Max 16mm

Connector Type: FC

Cable characteristics IEC 60793-1

Cable drum shall have fixed weatherproof identification of the following: Cable Drum shall be labeled with Manufacturer Name, Applicable IEC Standard,

Number(s) and type(s) of Fiber (s), Total Cable Length, Year of Manufacture, Manufacturing sequence order (Batch Number)

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Rev. 0 (July-2013) Page 23 of 24 Brunei Shell Petroleum Sdn. Bhd.

Standard BSP EFA Cables

Item SAP Material No. Simplified Cable Description Full Cable Specifications

43 1001694862 Fiber Optic, 16 Cores, Single Mode, Black

Fiber Optic Cable

Application Ethernet / VoIP/ Data/ CCTV/ Instrument Signal, Multi core

Flammability properties Flame Retardant, Low Smoke Zero Halogen

Design spec IEC 60793, IEC 60794 Part 3, IEC 60754 & IEC 61034 - LSZH

Construction Strength member, Fiber, Loose tube, moisture barrier sheath, PE inner sheath, SWA, PE outer sheath

Mat spec, Central Strength member Fiber Glass

Core Cladding Material/ Filling PBT Loose Tubes/ Jelly Filled

Mat spec, inner sheath Polyethylene, LSZH

Mat spec, outer sheath PE, LSZH

Colour, outer sheath Black

Armouring Single Layer of Galvanised Steel Wire

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, cores 16 cores

UV Resistant According To UL1581 – Sect 1200

Optical Fibre Type : Single Mode

Max Attenuation 0.4 dB/km @ wavelength 1300nm

Core Diameter: 8.7± 0.5µm

Cladding Diameter for Each core: 125 ± 2 µm

Outer Diameter: Max XXmm

Connector Type: FC

Cable characteristics IEC 60793-1

Cable drum shall have fixed weatherproof identification of the following: Cable Drum shall be labeled with Manufacturer Name, Applicable IEC Standard,

Number(s) and type(s) of Fiber (s), Total Cable Length, Year of Manufacture, Manufacturing sequence order (Batch Number)

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

44 1001694863 Fiber Optic, 24 Cores, Single Mode, Black

Fiber Optic Cable

Application Ethernet / VoIP/ Data/ CCTV/ Instrument Signal, Multi core

Flammability properties Flame Retardant, Low Smoke Zero Halogen

Design spec IEC 60793, IEC 60794 Part 3, IEC 60754 & IEC 61034 - LSZH

Construction Strength member, Fiber, Loose tube, moisture barrier sheath, PE inner sheath, SWA, PE outer sheath

Mat spec, Central Strength member Fiber Glass

Core Cladding Material/ Filling PBT Loose Tubes/ Jelly Filled

Mat spec, inner sheath Polyethylene, LSZH

Mat spec, outer sheath PE, LSZH

Colour, outer sheath Black

Armouring Single Layer of Galvanised Steel Wire

Flame, propagation FLAME RETARDANT to IEC-60332-1 and IEC60332-3-22

Number, cores 24 cores

UV Resistant According To UL1581 – Sect 1200

Optical Fibre Type : Single Mode

Max Attenuation 0.4 dB/km @ wavelength 1300nm

Core Diameter: 8.7± 0.5µm

Cladding Diameter for Each core: 125 ± 2 µm

Outer Diameter: Max XXmm

Connector Type: FC

Cable characteristics IEC 60793-1

Cable drum shall have fixed weatherproof identification of the following: Cable Drum shall be labeled with Manufacturer Name, Applicable IEC Standard,

Number(s) and type(s) of Fiber (s), Total Cable Length, Year of Manufacture, Manufacturing sequence order (Batch Number)

Length Identification: CABLE DIAMETER 10 mm AND ABOVE SHOULD BE MARKED WITH LENGTH IDENTIFICATION AT REGULAR INTERVALS OF 1 METER,STARTING

FROM "0" END WHICH IS ATTACHED TO THE SPINDLE OF THE DRUM.

Routine and Type test reports: TEST CERTIFICATES TO BE SUPPLIED PER BATCH, IDENTIFYING APPLICABLE DRUMS.

Rev. 0 (July-2013) Page 24 of 24 Brunei Shell Petroleum Sdn. Bhd.