Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

11
Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW

Transcript of Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

Page 1: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

Stand-By Emergency Lighting Inverter

Three Phase 3 KW – 125 KW

Page 2: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

What is the Cobra 3?It is a three phase

Emergency Lighting Inverterwhich is a stand-by unit.

It defends your environment againstunwanted power outage and

electrical disturbances. It continuallymaintains efficient (over 99%)

AC Emergency Power to operateall emergency lighting fixturesat “full-light” output, providing

Superior dependability and security tocommercial/industrial environments

in a small footprint.

It is available in power levels of3.0, 4.5, 6.0, 8.0, 10.0, 12.0, 16.0,20.0, 224.0, 30.0, 40.0 60.0, 80.0,

100.0 and 125.0 KW

Page 3: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

Why is the Cobra 3 better?With the increased environmental awareness and the

increase in energy costs, what are you to do?With the Cobra technology you can reduce both

energy cost and energy consumption.Cobra’s technology allows a much higherefficiency rating, consuming less power.

Consuming less energy saves your money andthe environment while keeping

the same dependability you expectfrom DSPM.

Page 4: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

What makes theCobra 3 different?

• DSPM Watchdog software always on guard.• Dependable DSP/PWM technology for unsurpassed reliability.• Economical for the lowest overall cost for your light safety, with an Energy Star Rating.• Temperature compensating technology that controls batteries for the longest battery life.• Sealed maintenance free batteries.• Full light output for entire 90 minutes.• Self-diagnostics for a safe and secure lighted environment.• Pure sine wave output for all types of lamps.• ECM module is a patented technology used by DSPM.• Backup solutions for multiple applications such as: indoor and outdoor emergency lighting, exits, cash registers, computers, strategic electronics and more!• 10 Year pro-rated battery warranty• 5 Year power train warranty• Meets federal, state and local codes: UL924, NFPA 101, NFPA 70, NEC and OSHA.• Cities of Chicago and New York Approved. • Complies with the Buy American Act.

Page 5: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

Specifications*Standard Power Levels.........**3.0, 4.5, 6.0, 8.0, 10.0, 12.0, 16.0, 20.0, 24.0, 30.0, 40.0 60.0, 80.0, 100.0 and 125.0 KW*Input Voltage ........................... 208Y/120, 480Y/277, 208 or 480VAC*Input Voltage Range................+10%. -15%*Output Voltage.........................208Y/120 or 480Y/277 VAC*Output Voltage Regulation......±3 for all loads and battery discharge mode*Output Frequency Range........60 Hz, ±1%Output Wave Form....................Sine-wave <5% @ 100% linear loadCrest Factor...............................2.5:1 typicalInput Protection.........................Input Main Circuit BreakerOutput Protection......................Output Main Circuit BreakerSurge Protection.......................The unit will protect itself and the load against surges

as defined in ANSI/EEE C62.45 category A and BBattery.......................................Sealed maintenance-free (AGM) lead calciumRecharge Current.....................Conforms to UL924 standardsExternal Battery........................Provision for hardware connection of

external battery cabinets or DC sourceEfficiency...................................≥99% at 100% linear loadAudible Noise............................<45dB measured on Response Curve “A” Safety Agencies........................Listed to UL standard 924Operating Temperature.............0º to 40ºC (32º to 104ºF)Storage Temperature................-20º to 60ºC (-4º to 140ºF)Humidity....................................5 - 95%, Non-condensingMonitoring.................................LED Displays Alarms and DiagnosticsTransfer Time............................16msec – 60msec*Consult factory for others.*No line to line loads for 3.0 – 6.0 KW units. Specifications subject to change without notice.

Page 6: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

OptionsEnvironmental Control ModuleNormally OFF Circuit 120VAC or 277VACNormally OFF “Hold On” 120VAC or 277VACOutput Circuit Breaker(s)Emergency Power OffRemote Indicator PanelEthernet Interface with RS232Fax ModemForm C ContactsSeismic-Rated BracketOnsite StartupInternal Dimmer BypassExternal Maintenance BypassExtended WarrantyFast Transfer

Subject to change without notice.

Page 7: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

System Drawing:

Specification

Chart:

Page 8: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

BrochureFor your convenience you can download the brochure with

all the information about our Cobra 3 from our website: www.dspmanufacturing.com

Page 9: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

Data SheetFor your convenience you can download the data sheet with

all the information along with how to order ourCobra 3 from our website: www.dspmanufacturing.com

Page 10: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

Other DownloadsFor your convenience you can also download the

technical specification, manual, field service documents, andwhite papers for the Cobra 3 from our website:

www.dspmanufacturing.com

Page 11: Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.

If you have any other questions or would like more information

Call 1.877.DSPM.POWER1.877.377.6769

Thank You!089-0011-01A