Series KFG
The insert mechanismprovides a reliable retaining force on the tube.
Fastens lightly.Adhesion or bindingalso prevented.
Sleeve
Union nut
Guide
Body
Prevents the tube from disconnecting during piping.
Tube can be connected without fully removing the nut.
Stainless Steel 316 Insert Fittings
Operating fluid temperature
–5 to 150 °CCan be used with steam.
Grease-free
Applicable tubing material
FEP, PFA, Nylon, Soft nylon, Polyurethane, Polyolefin
Material: Stainless Steel 316
CAT.EUS50-26 -UKA
Air, Water, Steam
–100 kPa to 1MPa
3.0 MPa
–5 to 150°C (No freezing)
Grease-free specification
With sealant
Operating fluid
Operating pressure range
Proof pressure
Ambient and Operating fluid temperature
Lubricant
Seal on the threads
Specifications
Stainless Steel 316 One-touch FittingsSeries KQG• Material: Metal parts/
Stainless steel 316Seal parts/Special FKM
• Operating fluid temperature: –5 to 150°C
• Grease-free
Port sizeApplicable tubing O.D.
ø4 ø6 ø8 ø10 ø12M5
R1/8
R1/4
R3/8
R1/2
Related Product
Male Connector: KFGHMale Connector: KFGH Male Branch Tee: KFGTMale Branch Tee: KFGT
Male Elbow: KFGLMale Elbow: KFGL
O.D. I.D.
Connectionthread
R1/8
R1/4
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R1/2
R1/4
R3/8
R1/2
KFGH0425-01SKFGH0425-02SKFGH0604-01SKFGH0604-02SKFGH0806-01SKFGH0806-02SKFGH0806-03SKFGH1075-02SKFGH1075-03SKFGH1075-04SKFGH1209-02SKFGH1209-03SKFGH1209-04S
ø2.5
ø4
ø6
ø7.5
ø9
ø4
ø6
ø8
ø10
ø12
Applicabletubing size Model
Applicabletubing size
O.D. I.D.
Connectionthread
R1/8
R1/4
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R1/2
R1/4
R3/8
R1/2
KFGT0425-01SKFGT0425-02SKFGT0604-01SKFGT0604-02SKFGT0806-01SKFGT0806-02SKFGT0806-03SKFGT1075-02SKFGT1075-03SKFGT1075-04SKFGT1209-02SKFGT1209-03SKFGT1209-04S
ø2.5
ø4
ø6
ø7.5
ø9
ø4
ø6
ø8
ø10
ø12
Model
O.D. I.D.
Connectionthread Model
R1/8
R1/4
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R1/2
R1/4
R3/8
R1/2
KFGL0425-01SKFGL0425-02SKFGL0604-01SKFGL0604-02SKFGL0806-01SKFGL0806-02SKFGL0806-03SKFGL1075-02SKFGL1075-03SKFGL1075-04SKFGL1209-02SKFGL1209-03SKFGL1209-04S
ø2.5
ø4
ø6
ø7.5
ø9
ø4
ø6
ø8
ø10
ø12
Applicabletubing size
Straight Union: KFGHStraight Union: KFGHApplicable tubing size
O.D. I.D.
ø2.5ø4ø6
ø7.5ø9
KFGH0425-00KFGH0604-00KFGH0806-00KFGH1075-00KFGH1209-00
ø4ø6ø8
ø10ø12
Applicable tubing size
O.D. I.D.
ø2.5ø4ø6
ø7.5ø9
KFGT0425-00KFGT0604-00KFGT0806-00KFGT1075-00KFGT1209-00
ø4ø6ø8
ø10ø12
Model
Model
Union Tee: KFGTUnion Tee: KFGT
Features 1
q
w
e
r
t
1
Stainless Steel 316Insert Fittings
Series KFG
Applicable Tubing
Specifications
Operating fluid
Operating pressure range Note)
Proof pressure
Ambient and Operating fluid temperature
Lubricant
Seal on the threads
Air, Water, Steam
–100 kPa to 1 MPa
3.0 MPa
–5 to 150°C (No freezing)
Grease-free specification
With sealant
Note) Please avoid using in a vacuum holding application such as a leak tester, as leakage may occur.
No.
12345
DescriptionSleeveUnion nutGuideMale connector bodyMale elbow body
Stainlesssteel 316
Material
Silver plated inner surfaceFluorine coating
Note
Component Parts
Construction
e qw
Series Tubing O.D.Tubing O.D. x I.D. (mm)
ø12 x ø9ø10 x ø7.5ø8 x ø6ø6 x ø4ø4 x ø2.5
TH
TL
T
TS
TU
TPH
TPS
FEP
PFA
Nylon
Soft nylon
Polyurethane
Polyolefin
Soft polyolefin
Dimensions
2
Series KFG
Male Connector: KFGHApplicabletubing size
ø4
ø6
ø8
ø10
ø12
ø2.5
ø4
ø6
ø7.5
ø9
KFGH0425-01SKFGH0425-02SKFGH0604-01SKFGH0604-02SKFGH0806-01SKFGH0806-02SKFGH0806-03SKFGH1075-02SKFGH1075-03SKFGH1075-04SKFGH1209-02SKFGH1209-03SKFGH1209-04S
R1/8
R1/4
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R1/2
R1/4
R3/8
R1/2
10
14
10
14
12
14
17
22
17
22
10
12
14
17
19
32
36
32.7
36.7
33.7
37.7
38.7
39.7
40.7
43.7
39.7
40.7
43.7
11.5
11.2
12.2
14.2
O.D. I.D.
Connec-tion
threadModel
Width across flats
H1 H2L M
1.5
3
5
6.5
8
1.6
6
17
30
45
ød
28
30
28.7
30.7
29.7
31.7
32.4
33.7
34.4
35.5
33.7
34.4
35.5
16
25
19
29
24
32
44
44
52
75
47
55
78
A∗ Weight(g)
∗ Reference dimensions after installation of R threadNote) Figures shown when using FEP tubing
Male Elbow: KFGLApplicabletubing size
ø4
ø6
ø8
ø10
ø12
ø2.5
ø4
ø6
ø7.5
ø9
KFGL0425-01SKFGL0425-02SKFGL0604-01SKFGL0604-02SKFGL0806-01SKFGL0806-02SKFGL0806-03SKFGL1075-02SKFGL1075-03SKFGL1075-04SKFGL1209-02SKFGL1209-03SKFGL1209-04S
R1/8
R1/4
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R1/2
R1/4
R3/8
R1/2
10
12
14
10
12
14
17
19
17
19
17
19
18
21
20
21
25
21
25
22
27
25
30
35
38
44
58
64
77
61
64
80
O.D. I.D.
Connec-tion
threadModel
Width across flats
H1 H2L1 L2
11.5
11.2
12.2
14.2
M
1.5
3
5
6.5
8
1.6
6
12
16
23
26
27
35
ød A∗ Weight(g)
∗ Reference dimensions after installation of R threadNote) Figures shown when using FEP tubing
19
20
22.1
23.1
21.8
24.8
24.5
26.6
26
25.6
27.7
29
29.7
31.2
33.2
36.7
39.7
36.7
39.7
L AM
Applicable tubing
Connection thread(with seal)
H2
H1
ød
L1
L2
A
M
H2
Connection thread(with seal)
H1
Applicable tubing
ød
Male Branch Tee: KFGTApplicabletubing size
ø4
ø6
ø8
ø10
ø12
ø2.5
ø4
ø6
ø7.5
ø9
KFGT0425-01SKFGT0425-02SKFGT0604-01SKFGT0604-02SKFGT0806-01SKFGT0806-02SKFGT0806-03SKFGT1075-02SKFGT1075-03SKFGT1075-04SKFGT1209-02SKFGT1209-03SKFGT1209-04S
R1/8
R1/4
R1/8
R1/4
R1/8
R1/4
R3/8
R1/4
R3/8
R1/2
R1/4
R3/8
R1/2
10
12
14
10
12
14
17
19
17
19
17
19
20
23
22
23
22
27
24
27
35
39
41
46
58
60
69
95
101
117
104
106
124
O.D. I.D.
Connec-tion
threadModel
Width across flats
H1 H2L1 L2
11.5
11.2
12.2
14.2
M
1.5
3
5
6.5
8
3
10
16
25
30
41
32
48
ød A∗ Weight(g)
Effectivearea Note)
(mm2)
Effectivearea Note)
(mm2)
Effectivearea Note)
(mm2)
∗ Reference dimensions after installation of R threadNote) Figures shown when using FEP tubing
19
20
24.1
25.1
23.8
26.8
25.5
28.6
29
28.6
29.7
29
29.7
31.2
33.2
36.7
39.7
36.7
39.7
ød
AL
2
M M
L1 L1
H2
Connection thread(with seal)
H2
2-applicable tubing
H1
3
Series KFGStainless Steel 316Insert Fittings
Straight Union: KFGHApplicabletubing size
ø4ø6ø8
ø10ø12
ø2.5ø4ø6
ø7.5ø9
KFGH0425-00KFGH0604-00KFGH0806-00KFGH1075-00KFGH1209-00
8
10
12
17
10
12
14
17
19
O.D. I.D.
Model
Width across flats
H1 H2L
11.5
11.2
12.2
14.2
M
1.5
3
5
6.5
8
1.6
6
17
30
45
ød Weight(g)
Note) Figures shown when using FEP tubing.
43.9
45.4
48.4
52.4
52.3
20
28
39
63
73
Union Tee: KFGTApplicabletubing size
ø4ø6ø8ø10ø12
ø2.5ø4ø6
ø7.5ø9
KFGT0425-00KFGT0604-00KFGT0806-00KFGT1075-00KFGT1209-00
10
12
14
10
12
14
17
19
O.D. I.D.
Model
Width across flats
H1 H2L
11.5
11.2
12.2
14.2
M
1.5
3
5
6.5
8
42
52
70
117
128
1.6
6
17
30
45
ød Weight(g)
Effectivearea Note)
(mm2)
Effectivearea Note)
(mm2)
Note) Figures shown when using FEP tubing.
29
29.7
31.2
36.7
Sleeve: KFGSApplicabletubing O.D.
ø4ø6ø8ø10ø12
KFGS-04KFGS-06KFGS-08KFGS-10KFGS-12
8
9
6.5
8.5
10.5
13
15
Model LøD
0.7
0.9
1.2
2.1
2.2
Weight(g)
Union Nut: KFGNApplicabletubing O.D.
ø4ø6ø8ø10ø12
KFGN-04KFGN-06KFGN-08KFGN-10KFGN-12
15
16
18
10
12
14
17
19
ModelWidth
across flatsH
L
5
6
8
11.5
13.5
Weight(g)
M ML
H2H1
2-applicable tubing
H2
ød
øD
L
L
H
ML
MLL
M
H2H2
3-applicable tubing
H1
H2
ød
ød
Dimensions
Compatibility Checklist for Used Materials and Fluids
Note 1) [ ] denotes the concentration. Aqueous solutions without condensation notes are in a saturated state.
Note 2) The above data is based on a room temperature of 20°C. Note that you may obtain different figures, depending on temperature conditions.
Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance. In addition, using fluids other than those specified in the catalog are not covered by the product’s warranty.
How to Read the Table
: Completely unaffected or largely unaffected. : May be slightly affected, but, dependent upon
condition, can sufficiently withstand. : Advisable to use as little as possible. : Not applicable, as substantially affected. : No data is available.
ChemicalMain body
Stainless steel 316
Acrylonitrile
Acetamide
Acetaldehyde
Acetone
Aniline
Amylene
Sulphurous acid gas (Humid gas)
Sodium bisulfite [50%]
Allyl alcohol
Benzoic acid
Ammonia (Compressed gas)
Isopropyl alcohol
Isophorone
Ethyl alcohol
Ethyl ether
Ethylene
Ethylene glycol
Ethylene diamine
Ethylene dichloride
Epichlorohydrine
Methyl tertiary butyl ether
Allyl chloride
Ammonium chloride
Calcium chloride
Iron chloride (II) [5%]
Sodium chloride
Magnesium chloride
Hydrochloric acid [5%]
Chlorine gas (Humid gas)
Carbitol
Formic acid [50%]
o-Xylene
p-Xylene
ChemicalMain body
Stainless steel 316
Citric acid
Cumene
Glycerin
Cresol
Chromic acid [10%]
Chlorosulfonic acid
Chlorofluorocarbon (CFC) 11
Chlorofluorocarbon (CFC) 113
Chlorofluorocarbon (CFC) 12
Chlorofluorocarbon (CFC) 13B1
Chlorofluorocarbon (CFC) 14
Chlorofluorocarbon (CFC) 22
Chlorobenzene
Chloroform (Trichloromethane)
Acetic acid
Amyl acetate
Isopropyl acetate [20%]
Ethyl acetate
Butyl acetate
Methyl acetate
Calcium hypochlorite
Sodium hypochlorite [5%]
Potassium cyanide [50%]
Copper cyanide
Diisobutyl ketone
Diisobutylene
Diethanolamine
Diethylamine
Diethylene glycol
Carbon tetrachloride
Cyclohexanol
Cyclohexanone
Cyclohexane
4
Series KFGApplicable Fluid Compatibility List
Compatibility Checklist for Used Materials and Fluids
Note 1) [ ] denotes the concentration. Aqueous solutions without condensation notes are in a saturated state.
Note 2) The above data is based on a room temperature of 20°C. Note that you may obtain different figures, depending on temperature conditions.
Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance. In addition, using fluids other than those specified in the catalog are not covered by the product’s warranty.
How to Read the Table
: Completely unaffected or largely unaffected. : May be slightly affected, but, dependent upon
condition, can sufficiently withstand. : Advisable to use as little as possible. : Not applicable, as substantially affected. : No data is available.
ChemicalMain body
Stainless steel 316
Dichloroethylene
Dichlorobenzene
Dichloromethane (Methylene chloride)
Ethylene bromide
Potassium bromide [30%]
Potassium dichromate [25%]
Oxalic acid
Bromine gas
Tartaric acid
Nitric acid [65%]
Ammonium nitrate
Ammonium hydroxide
Calcium hydroxide
Sodium hydroxide [50%]
Barium hydroxide
Solvent naphtha
Tetrachloroethylene
Tetrahydrofuran
Dodecylbenzene
Trichloroethane
Trichloroethylene
Trichloroacetic acid
Toluene
Naphtha
Naphthenic acid
Lactic acid
Carbon disulfide
Picric acid
Pyridine
Phenol
Carbonic acid (Humid gas and aqueous solution)
ChemicalMain body
Stainless steel 316
Butyl phthalate
Butyl alcohol
Hydrofluoric acid [50%]
Furfurol
n-Propyl alcohol
Propylene glycol
Bromochloroethane
n-Hexane
n-Hexyl alcohol
n-Heptane
Benzene
n-Pentane
Boric acid
Gallic acid
Formic aldehyde
Methyl methacrylate
Methyl alcohol
Methyl isobutyl ketone
Methyl ethyl ketone
Ethyleneglycol monomethyl ether
Monoethanolamine
Morpholine
Butyric acid
Sulphuric acid [10%]
Ammonium sulfate
Sodium bisulfate [10%]
Iron sulfate (ll)
Sodium sulfate
Phosphoric acid [85%]
Hydrogen sulfide (Humid gas and aqueous solution)
5
Series KFGApplicable Fluid Compatibility List
Back page 1
Series KFG
Safety Instructions
1. The compatibility of the pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalogue information with a view to giving due consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery and equipment.Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. (Understanding JIS B 8370 General Rules for Pneumatic Equipment, and other safety rules are included.)
3. Do not service machinery/equipment or attempt to remove components until safety is confirmed.1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway
of the driver objects have been confirmed. 2. When equipment is removed, confirm that safety process as mentioned above. Turn off the supply pressure for this equipment
and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity).3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc.
4. Contact SMC if the product will be used in any of the following conditions:1. Conditions and environments beyond the given specifications, or if product is used outdoors.2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and
beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment.3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis.4. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for
the prevention of a breakdown. And, examine the devices periodically if they function normally or not.
These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices.
Note 1) ISO 4414: Pneumatic fluid power – General rules relating to systemsNote 2) JIS B 8370: General Rules for Pneumatic EquipmentNote 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalisation or hospital visits for long-term medical treatment.Note 4) Equipment damage refers to extensive damage to the equipment and surrounding devices.
Danger In extreme conditions, there is a possible result of serious injury or loss of life.
Warning Operator error could result in serious injury or loss of life.
Caution Operator error could result in injury Note 3) or equipment damage Note 4).
Labels Explanation of the labels
Explanation of the Labels
Selection/Handling/Applications
1. SMC, its officers and employees shall be exempted from liability for any loss or damage arising out of earthquakes or fire, action by a third person, accidents, customer error with or without intention, pro-duct misuse, and any other damages caused by abnormal operating conditions.
2. SMC, its officers and employees shall be exempted from liability for any direct or indirect loss or dama-ge, including consequential loss or damage, loss of profits, or loss of chance, claims, demands, pro-ceedings, costs, expenses, awards, judgments and any other liability whatsoever including legal costs and expenses, which may be suffered or incurred, whether in tort (including negligence), contract, breach of statutory duty, equity or otherwise.
3. SMC is exempted from liability for any damages caused by operations not contained in the catalogues and/or instruction manuals, and operations outside of the specification range.
4. SMC is exempted from liability for any loss or damage whatsoever caused by malfunctions of its pro-ducts when combined with other devices or software.
Exemption from Liability
Back page 2
4) When the union nut is loose, tighten it additionally, tempora-rily by hand.
5) After fixing the body with the tightening tool, tighten the union nut by 1.5 turns, using an appropriate wrench. Shown below is the equivalent tightening torque.
When tightening the nut, the laser marking can be used for reference.
Laser marking
Series KFGSpecific Product Precautions 1Be sure to read this before handling. For Safety Instructions, refer to the back of page 1.For Fittings and Tubing Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A).
Fitting size
KFG0425
KFG0604
KFG0806
KFG1075
KFG1209
Equivalent tightening torque N m
7 to 9
11 to 13
13 to 15
16 to 18
16 to 18
1. Do not use in locations where the connecting threads and tu-bing connection will slide or rotate. The connecting threads and tubing connection will come apart under these conditions.
2. Use tubing at or above the minimum bending radius. Using below the minimum bending radius can cause breakage or flattening of the tube.
3. Consult with SMC regarding fluids other than air, water andsteam.
4. In case of liquid fluids, keep surge pressure at or below the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, damage to the fittings and tubing may occur.
Selection
Caution
1. Before mounting, please confirm that the model, size, etc. are correct. In addition, please confirm that there are no blemishes, nicks or cracks in the product.
2. When tubing is connected, consider factors such as changes in the tubing length due to pressure, and give adequate spa-ce.
3. Mount so that the fittings and tubing are not subjected to strain or moment loads. This can cause damage to the fittings and flattening, bursting or disconnection of the tubing, etc.
4. Mount so that the tubing is not damaged due to tangling and abrasion. This can cause flattening, bursting or disconnection of the tubing, etc.
Mounting
Caution
1. Taper threadsWhen installing, tighten with the proper torque shown in the table below. As a rule, this corresponds to two or three turns with a tool after being tightened by hand.
2. Tightening toolsTighten with an appropriate wrench using the hexagon wrench flats on the body.Tighten by placing an appropriate wrench firmly against the fit-ting body. Position the wrench on the base as close as possi-ble to the threads. If the wrench size is not correct, the fitting body may be damaged.
Installation of Threads
Caution
Connection thread size
R 1/8
R 1/4
R 3/8
R 1/2
Proper tightening torque N⋅m
7 to 9
12 to 14
22 to 24
28 to 30
CautionInstallation and Removal of Tubing
1. Installation of tubing1) Take a tube with no flaws on its periphery and cut it off at a
right angle. Do not use pinchers, nippers or scissors, etc. The tubing might be cut diagonally or flattened, making ins-tallation impossible or causing problems such as discon-nection and leakage.
2) Without loosening the union nut, grab the tube and gently push it thoroughly into the fitting.
3) After insertion, confirm that the tube will not disconnect.
Back page 3
TubingRecyclable life
5 times
Twice
Series
THTL
TTSTU
TPHTPS
Material
FEPPFA
NylonSoft nylon
PolyurethanePolyolefin
Soft polyolefin
Recyclable Life for Body and Union Nut
Series KFGSpecific Product Precautions 2Be sure to read this before handling. For Safety Instructions, refer to the back of page 1.For Fittings and Tubing Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A).
1. Pre-maintenance inspectionWhen the product is to be removed, turn off the power, cut off the supply pressure, and confirm that fluid in the piping has been discharged.
2. During regular maintenance, check for the following and repla-ce any components as necessary.a) Scratches, gouges, abrasion, corrosionb) Leakagec) Flattening or distortion of tubingd) Hardening, deterioration or softness of tubing
3. Do not repair the fittings or patch the tubing for reuse.
4. Using this product for extended periods of time can result in leaks due to the material change. In such cases, perform adit-tional tightening to the unit nut.A guide for the additional tightening is 1/6 to 1/4 turns. The li-mit for additional tightening is 1/2 turns.When there is a leak even after additional tightening, replace the sleeve and union nuts with new ones.
5. Sleeve is not reusable. Replace it every time piping is perfor-med.Body and union nut are reusable. Refer to the table below for reusable life.
Maintenance
Caution1. Do not use in environments or locations where there is danger
of damage to the fittings and tubing.For fitting and tubing materials, refer to specifications and construction drawings, etc.
2. Do not operate in locations where vibration or impact occurs because this can cause leakage, damage to fittings, etc. Plea-se contact SMC regarding use in these environments.
Operating Environment
Warning
1. Our product warranty is not valid if tubing brands other than that from SMC are used.
Precautions on Use of Other Tubing Brands
Caution
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
ARGENTINA, AUSTRALIA, BOLIVIA, BRASIL, CANADA, CHILE,CHINA, HONG KONG, INDIA, INDONESIA, MALAYSIA, MEXICO,NEW ZEALAND, PHILIPPINES, SINGAPORE, SOUTH KOREA,
TAIWAN, THAILAND, USA, VENEZUELA
OTHER SUBSIDIARIES WORLDWIDE:
© DiskArt™ 1988
© DiskArt™ UKSMC Pneumatics (UK) LtdVincent Avenue, Crownhill, Milton Keynes, MK8 0ANPhone: +44 (0)800 1382930 Fax: +44 (0)1908-555064E-mail: [email protected]://www.smcpneumatics.co.uk
AustriaSMC Pneumatik GmbH (Austria).Girakstrasse 8, A-2100 KorneuburgPhone: +43 2262-62280, Fax: +43 2262-62285E-mail: [email protected]://www.smc.at
Czech RepublicSMC Industrial Automation CZ s.r.o.Hudcova 78a, CZ-61200 BrnoPhone: +420 5 414 24611, Fax: +420 5 412 18034E-mail: [email protected]://www.smc.cz
PortugalSMC Sucursal Portugal, S.A.Rua de Engº Ferreira Dias 452, 4100-246 PortoPhone: +351 22-610-89-22, Fax: +351 22-610-89-36E-mail: [email protected]://www.smces.es
BelgiumSMC Pneumatics N.V./S.A.Nijverheidsstraat 20, B-2160 WommelgemPhone: +32 (0)3-355-1464, Fax: +32 (0)3-355-1466E-mail: [email protected]://www.smcpneumatics.be
LithuaniaSMC Pneumatics Lietuva, UABSavanoriu pr. 180, LT-01354 Vilnius, LithuaniaPhone: +370 5 264 81 26, Fax: +370 5 264 81 26
LatviaSMC Pneumatics Latvia SIASmerla 1-705, Riga LV-1006, LatviaPhone: +371 781-77-00, Fax: +371 781-77-01E-mail: [email protected]://www.smclv.lv
SwedenSMC Pneumatics Sweden ABEkhagsvägen 29-31, S-141 71 HuddingePhone: +46 (0)8-603 12 00, Fax: +46 (0)8-603 12 90E-mail: [email protected]://www.smc.nu
FranceSMC Pneumatique, S.A.1, Boulevard de Strasbourg, Parc Gustave EiffelBussy Saint Georges F-77607 Marne La Vallee Cedex 3Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010E-mail: [email protected]://www.smc-france.fr
FinlandSMC Pneumatics Finland OYPL72, Tiistinniityntie 4, SF-02031 ESPOOPhone: +358 207 513513, Fax: +358 207 513595E-mail: [email protected]://www.smc.fi
EstoniaSMC Pneumatics Estonia OÜLaki 12-101, 106 21 TallinnPhone: +372 (0)6 593540, Fax: +372 (0)6 593541E-mail: [email protected]://www.smcpneumatics.ee
GreeceS. Parianopoulus S.A.7, Konstantinoupoleos Street, GR-11855 AthensPhone: +30 (0)1-3426076, Fax: +30 (0)1-3455578E-mail: [email protected]://www.smceu.com
TurkeyEntek Pnömatik San. ve Tic Ltd. Sti.Perpa Tic. Merkezi Kat: 11 No: 1625, TR-80270 Okmeydani IstanbulPhone: +90 (0)212-221-1512, Fax: +90 (0)212-221-1519E-mail: [email protected]://www.entek.com.tr
PolandSMC Industrial Automation Polska Sp.z.o.o.ul. Konstruktorska 11A, PL-02-673 Warszawa, Phone: +48 22 548 5085, Fax: +48 22 548 5087E-mail: [email protected]://www.smc.pl
NetherlandsSMC Pneumatics BVDe Ruyterkade 120, NL-1011 AB AmsterdamPhone: +31 (0)20-5318888, Fax: +31 (0)20-5318880E-mail: [email protected]://www.smcpneumatics.nl
IrelandSMC Pneumatics (Ireland) Ltd.2002 Citywest Business Campus, Naas Road, Saggart, Co. DublinPhone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500E-mail: [email protected]://www.smcpneumatics.ie
HungarySMC Hungary Ipari Automatizálási Kft.Budafoki ut 107-113, H-1117 BudapestPhone: +36 1 371 1343, Fax: +36 1 371 1344E-mail: [email protected]://www.smc-automation.hu
SwitzerlandSMC Pneumatik AGDorfstrasse 7, CH-8484 WeisslingenPhone: +41 (0)52-396-3131, Fax: +41 (0)52-396-3191E-mail: [email protected]://www.smc.ch
ItalySMC Italia S.p.AVia Garibaldi 62, I-20061Carugate, (Milano)Phone: +39 (0)2-92711, Fax: +39 (0)2-9271365E-mail: [email protected]://www.smcitalia.it
GermanySMC Pneumatik GmbHBoschring 13-15, D-63329 EgelsbachPhone: +49 (0)6103-4020, Fax: +49 (0)6103-402139E-mail: [email protected]://www.smc-pneumatik.de
SloveniaSMC industrijska Avtomatika d.o.o.Grajski trg 15, SLO-8360 ZuzemberkPhone: +386 738 85240 Fax: +386 738 85249E-mail: [email protected]://www.smc-ind-avtom.si
SlovakiaSMC Priemyselná Automatizáciá, s.r.o.Námestie Martina Benku 10, SK-81107 BratislavaPhone: +421 2 444 56725, Fax: +421 2 444 56028E-mail: [email protected]://www.smc.sk
RomaniaSMC Romania srlStr Frunzei 29, Sector 2, BucharestPhone: +40 213205111, Fax: +40 213261489E-mail: [email protected]://www.smcromania.ro
NorwaySMC Pneumatics Norway A/SVollsveien 13 C, Granfos Næringspark N-1366 LysakerTel: +47 67 12 90 20, Fax: +47 67 12 90 21E-mail: [email protected]://www.smc-norge.no
DenmarkSMC Pneumatik A/SKnudsminde 4B, DK-8300 OdderPhone: +45 70252900, Fax: +45 70252901E-mail: [email protected]://www.smcdk.com
RussiaSMC Pneumatik LLC.4B Sverdlovskaja nab, St. Petersburg 195009Phone.:+812 718 5445, Fax:+812 718 5449E-mail: [email protected]://www.smc-pneumatik.ru
SpainSMC España, S.A.Zuazobidea 14, 01015 VitoriaPhone: +34 945-184 100, Fax: +34 945-184 124E-mail: [email protected]://www.smces.es
http://www.smceu.comhttp://www.smcworld.com
EUROPEAN SUBSIDIARIES:
BulgariaSMC Industrial Automation Bulgaria EOOD16 kliment Ohridski Blvd., fl.13 BG-1756 SofiaPhone:+359 2 9744492, Fax:+359 2 9744519E-mail: [email protected]://www.smc.bg
CroatiaSMC Industrijska automatika d.o.o.Crnomerec 12, 10000 ZAGREBPhone: +385 1 377 66 74, Fax: +385 1 377 66 74E-mail: [email protected]://www.smceu.com
1st printing KT printing KT 00 UK Printed in Spain