Stahl Hazardous Area Product Catalogue

592
condensed catalogue 2014 Products for explosive gas atmospheres and areas with combustible dust Explosion protected electrical equipment Systems and components for automation Explosion protected light fittings and emergency lighting systems

description

Stahl Hazardous Area Product Catalogue

Transcript of Stahl Hazardous Area Product Catalogue

  • 1. condensed catalogue 2014Products for explosive gas atmospheres and areas with combustible dustExplosion protected electrical equipmentSystems and components for automationExplosion protected light fittings andemergency lighting systems

2. 2013-09-10KP00IIIenExplosion Protection by R. STAHL - General CatalogueSalesR. STAHLAm Bahnhof 30 74638 Waldenburg (Wrtt.) ET +49 (0) 79 42 / 943 - 0 F +49 (0) 79 42 / 943 - [email protected] www.stahl.dePlease find your contact person under the sales organisation, see page 588R. STAHL www.stahl.deThe newest CDwith the R. STAHLcatalogue can beobtained from yourR. STAHL partner. 3. Condensed Catalogue 2014valid as of January 2014Seite0 General Information 2Terms of Sale and Delivery | Pictograms | WebCodeA2 Safety Barriers 4General | Single-Channel-Safety Barriers | Dual-Channel-Safety BarriersA3 Isolators 12Overview | Power Supply | Transmitter | Isolating Repeater | Switching RepeaterRelay Module | Binary Output | HART-Multiplexer | System Components | pac-Bus | pac CarrierA4 Remote I/O 74General Information | CPU & Power Modules | BusRail | Temperature Input ModulesInput/Output Modules for Analog Signals | Input/Output Modules for Digital SignalsA5 Fieldbus Technology 118General Information | Power Supply and Diagnosis | Field Device Coupler | System Components and AccessoriesA6 Wireless 140General Information | WLAN Access Point | Localisation System | WirelessHART GatewayA7 Operating and Monitoring Systems 152System Description | Remote HMI | Open HMI | Operator Interfaces EagleOperator Interfaces Falcon | EnclosuresA8 Camera and Video Systems 234Camera Systems for all Areas | Cameras | Video SoftwareE2 Lighting 254Compact Light Fittings | Light Fittings for Flourescent Lamps | Tubular Light Fittings | Emergency Light FittingsLED Cluster Lighting | Pendant Light Fittings | Bulkhead Light Fittings | Floodlights |Portable Lamps | Hand LampsE3 Installation Equipment 326Installation Switches | Junction Boxes | Terminal Boxes | Connection Technology for Data Networks | Plug ConnectorsPlugs and Sockets | Couplers | Coupler Sockets | Socket Outlet Assemblies | Maintenance Socket Isolators | Cable ReelE4 Control Devices 378Position Switches | Radio Position Switches | Control Equipment for Panel Mounting | Control Device SystemGrounding Systems and Grounding Monitoring Devices | Measuring and Monitoring Equipment for Panel MountingE5 Signalling Devices 452Visual Signalling Devices | Audible and Visual Signalling Devices | Audible Signalling Devices | Operator PanelsE6 Components for Heating Systems 496Junction Boxes for Heat Tracing | Temperature Controller and Limiter | Thermostats | AccessoriesE7 Load Disconnect Switches and Motor Starters 514Safety Switches | Load and Motor Switchgear | Motor Protection Circuit-Breakers | Standard Motor StartersDirect On-Line Motor Starters | Star-Delta Starter Combinations | Reversing Starter CombinationsE8 Applications Low Voltage Systems 532Power Distribution | Lighting and Heating Panels | Machine Controls | Battery BoxesUPS Uninterrupted Power Supply | Pressurized ApparatusE9 Components for System Solutions 544Ex d Technology | Ex e Technology | Components for Use in Ex d and Ex e EnclosuresE10 Installation Equipment and Accessories 548Cable Glands | Cable Glands with Strain Relief | Cable Glands in BrassBreathing Glands | Stopping Plugs | AccessoriesType Index - Sales Organisation / International 584Type Index | Addresses2013-09-10KP00IIIen Contents 1 4. 0Condensed Catalogue 2014Conditions of Sales and Delivery, Pictograms and WebCodeConditions of Sales and DeliveryThe list on hand will be valid as of 2014-01-01.All lists published up to now, including the technicalspecifications and the conditions of sale and delivery,will then be no longer valid and will be replaced by thelist on hand.All deliveries and services are based on ourGeneral Terms and Conditions of Delivery.They become an integral part of the contract with each orderand can be viewed under the link:www.stahl.de / DOWNLOADSChanges of technical data, dimensions, weights, design andavailability are reserved.The items in this list form a focus of our program of delivery.This Condensed Catalogue will be run with a higherstockpiling of devices and component parts.With our Condensed Catalogue we want to make yourscheduling and warehousing easier.If you will favour these devices during construction and projectplanning you will secure yourself particularly convenientdelivery times.You may find the complete delivery program in ourgeneral catalogue and up-to-date in our online-cataloguewww.stahl.de.Pictograms Application of the PictogramsEx Symbolfor all devices in explosion-protected designOffshorefor all devices that are suitable for offshore applications. When the materials areselected special importance is put on the harsh conditions of seawater atmosphere.Shippingfor all devices with ship approvalLow temperaturefor all devices that may be used in temperatures below -20 CHigh temperaturefor all devices that may be used in temperatures higher than +40 CR. STAHL Schaltgerte GmbHProduct Segments PSIn the present Condensed Catalogue you will find anassociated product segment with every item number.This allows a computerized classification of definedproduct segments and delivery conditions.Mark-up for small-volume purchasesFor purchase orders with a net order value < 100 Euro we willcharge a mark-up for small-volume purchases of 25 Euro net.CancellationWe will charge a processing fee of 50 Euro net for thecancellation of an order. With special productions according tothe orders the cancellation costs will depend on the productionstage.RepurchaseRepurchases are only possible for unopened regular stockon hand, within 6 months after delivery and only with priorconsultation. If the goods have been returned freight prepaidand after the quality of the returned goods has been acceptedwe will credit 70% of the product invoice value.2 2013-09-10KP00IIIen 5. 0Condensed Catalogue 2014Conditions of Sales and Delivery, Pictograms and WebCodeWebCode DescriptionBy entering the WebCode on our homepage www.stahl.de you will be led directlyWebCode XXXXXXX to the respective documents.WebCode Example: Installation Switch Series 8030/51WebCode 8030A2013-09-10KP00IIIen R. STAHL Schaltgerte GmbH 3 6. Safety Barriers4 Safety Barrieres 2013-09-10KP00IIIen 7. A2ContentsSafety BarriersSingle-Channel Safety Barriers INTRINSPAK 9001 6Dual-Channel Safety Barriers INTRINSPAK 9002 8Safety Barriers with Electronic Current Limitation INTRINSPAK 9004 10You will find further information on the Internet www.stahl.deGeneral InformationEngineeringApplication ExamplesAccessories and Spare Parts2013-09-10KP00IIIen Safety Barriers 5 8. A2A2A2A2A2A2A2A2A2A2A2A2A2A2Safety BarriersSeries 9001 / 9002 / 9004Series 9001 / 9002 / 9004 A210064E009001: WebCode 9001A> Complete product range for all standardapplications> Flexible and space saving - single anddual channel versions on 12 mm only> Time-saving installation thanks tosimultaneous snapping onto the rail and connecting to PE and earth> Reduced inventory due to uniformexchangeable fuse9002: WebCode 9002A9004: WebCode 9004AATEX / IECEX NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 29001, 9002:x x x x x x 9001, 9002:Ex i interfaces9004:Ex i interfacesx x x x 9004:Installation in x x Installation in x x Installation in x x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIIEx i interfaces9001, 9002:Ex i interfacesx x x x x xEx i interfaces9004:Ex i interfacesx x xTechnical DataVersion 9001 9002 9004Explosion protectionGlobal (IECEx)Gas and dust IECEx PTB 09.0001X IECEx PTB 08.0057X IECEx PTB 12.0003XEx nA [ia Ga] IIC T4 Gc[Ex ia Da] IIICEx nA [ia Ga] IIC T4 Gc[Ex ia Da] IIICEx nA [ib Gb] IIC T4 GcEx nA [ib Gb] IIB T4 Gc[Ex ib Db] IIICEurope (ATEX)Gas and dust PTB 01 ATEX 2088 X PTB 01 ATEX 2053 X PTB 02 ATEX 2008E II 3 (1) G Ex nA [ia Ga]IIC/IIB T4 GcE II (1) D [Ex ia Da] IIICE II 3 (1) G Ex nA [ia Ga]IIC/IIB T4 GcE II (1) D [Ex ia Da] IIICE II (2) GD [EEx ib] IIB/IICE II 3 G EEx nA II T4(Installation in Zone 2)Certifications and certificatesCertificates IECEx, ATEX, Canada (CSA),Kazakhstan(operating licence),Russia (GOST R),Serbia (SRPS), Ukraine (TR),Belarus (operatingauthorisation)IECEx, ATEX, Canada (CSA),Kazakhstan(operating licence),Russia (GOST R),Serbia (SRPS), Ukraine (TR),USA (FM, UL), Belarus(operating authorisation)IECEx, ATEX, Canada (CSA),Kazakhstan(operating authorisation),Russia (GOST R),Serbia (SRPS), Ukraine (TR),Belarus (operatingauthorisation)Further parametersInstallation in Zone 2, Division 2 and in safe areaFurther information see respective certificate and operating instructionsEnclosure material Polyamide 6 GFDegree of protectionaccording to IEC 60529terminal enclosure:housing:IP20IP40Connection type 4 cage terminals, each maximum 1.5 mm2 flexible / solid2 PA-terminals, each maximum 4 mm2 flexible / solidAmbient temperatureAmbient temperature -20 ... +60 CStorage -20 ... +75 CDimensions 12 x 104 x 70 mmWeight approx. 0.115 kg6 Safety Barriers 2013-09-10KP00IIIen 9. A2A2A2A2A2A2A2A2A2A2A2A2A2A2Safety BarriersSeries 9001 / 9002 / 9004Selection tableUN Rmax Safety data Schematic Order number Art. no. PSUo Io PoV V mA mWSingle-Channel Safety Barriers for Negative Polarity Series 9001/006 32 8.6 390 839 Pic. A 9001/00-086-390-101 158434 2024 375 28 85 595 Pic. A 9001/00-280-085-101 158344 20319 28 100 700 Pic. A 9001/00-280-100-101 158356 20Single-Channel Safety Barriers for Positive Polarity Series 9001/016 27 8.3 442 917.2 Pic. B 9001/01-083-442-101 158338 20218 8.6 50 107.5 Pic. B 9001/01-086-050-101 158379 2073 8.6 150 322.5 Pic. B 9001/01-086-150-101 158418 2032 8.6 390 839 Pic. B 9001/01-086-390-101 158439 208 106 12.6 150 473 Pic. B 9001/01-126-150-101 158502 2012 135 15.8 150 593 Pic. B 9001/01-158-150-101 158535 2053 15.8 390 1541 Pic. E 9001/01-158-390-101 158509 20262 16.8 75 315 Pic. B 9001/01-168-075-101 158568 2016 241 19.9 100 498 Pic. B 9001/01-199-100-101 158632 20168 19.9 150 746 Pic. B 9001/01-199-150-101 158638 2066 19.9 390 1940 Pic. E 9001/01-199-390-101 158519 2020 ... 35 505 25.2 57 359 Pic. C 9001/01-252-057-141 158689 20505 25.2 60 378 Pic. D 9001/01-252-060-141 158693 20268 25.2 100 630 Pic. M 9001/01-252-100-141 158697 2024 666 28 50 350 Pic. B 9001/01-280-050-101 158665 20375 28 85 595 Pic. B 9001/01-280-085-101 158351 20319 28 100 700 Pic. B 9001/01-280-100-101 158365 20294 28 110 770 Pic. B 9001/01-280-110-101 158380 20198 28 165 1155 Pic. B 9001/01-280-165-101 158392 20124 28 280 1960 Pic. E 9001/01-280-280-101 158722 20Single-Channel Safety Barriers for Alternating Polarity Series 9001/020.7 134 1.6 15 6 Pic. F 9001/02-016-015-101 158669 2043 1.6 50 20 Pic. F 9001/02-016-050-101 158673 2020 1.6 150 60 Pic. F 9001/02-016-150-101 158681 2020.1 1.6 150 60 Pic. F 9001/02-016-150-111 158685 206 354 9.3 30 69.8 Pic. F 9001/02-093-030-101 158743 2079 9.3 150 348.8 Pic. F 9001/02-093-150-101 158753 2036 9.3 390 906.8 Pic. F 9001/02-093-390-101 158755 20Single-Channel Diode Return Barriers for Positive Polarity Series 9001/0316 19.9 0 0 Pic. G 9001/03-199-000-101 158475 2024 28 0 0 Pic. G 9001/03-280-000-101 158486 20Single-Channel Safety Barriers for Transmitter Series 9001/5120 ... 35 28 110 770 Pic. K 9001/51-280-110-141 158530 20 28 91 637 Pic. L 9001/51-280-091-141 158524 202013-09-10KP00IIIen Safety Barriers 7 10. A2A2A2A2A2A2A2A2A2A2A2A2A2A2Safety BarriersSeries 9001 / 9002 / 9004Schematic for Single-Channel Safety Barriers Series 9001Picture A Picture B Picture CPicture D Picture E Picture F+ UN + UN Ex iPicture G Picture K Picture LPicture MSelection tableChannel UN Rmin Rmax Safety data Schematic Order number Art. no. PSV V mA mWDual-Channel Safety Barriers Polarity: - / - Series 9002/00121+222.517.5- -321416- -Dual-Channel Safety Barriers Polarity: + / - Series 9002/10121+266- -490490- -121+266- -4242- -Safety Barriers09405E00 09406E00 09407E0009408E00 09409E00 09410E0009411E00 09415E00 09416E0009417E00Uo Io Po358463- -2620268751138540245785Pic. C 9002/00-260-138-001 158867 20543543- -9.339.3318.7202020505090Pic. A 9002/10-187-020-001 158937 204949- -9.339.3318.72702702706306301260Pic. A 9002/10-187-270-001 158933 208 2013-09-10KP00IIIen 11. A2A2A2A2A2A2A2A2A2A2A2A2A2A2Safety BarriersSeries 9001 / 9002 / 9004Selection tableChannel UN Rmin Rmax Safety data Schematic Order number Art. no. PSUo Io PoV V mA mWDual-Channel Safety Barriers Polarity: + / + Series 9002/11121+21616- -14231423- -15761576- -19.919.919.91515307575150Pic. B 9002/11-199-030-001 158929 20121+222.517.5- -321416- -358463- -2620268751138570260850Pic. B 9002/11-260-138-001 158870 20121+22525- -321321- -358358- -28282893931866506501300Pic. B 9002/11-280-186-001 158848 20Dual-Channel Safety Barriers Safety Barrier Polarity: + / Signal Barrier Polarity: + Series 9002/13121+21616- -95- -- -108- -- -19.919.919.922232251100151120Pic. F 9002/13-199-225-001 158921 20121+220 - 3522- -216- -- -243- -- -25.225.225.2118012174020760Pic. N 9002/13-252-121-041 158830 20121+22424- -321- -- -358- -- -2828289039363021651Pic. F 9002/13-280-093-001 158852 20121+220 - 3526- -292- -- -327- -- -28282897010067921700Pic. G 9002/13-280-100-041 158818 20121+22424- -269- -- -290- -- -282828107311074921770Pic. F 9002/13-280-110-001 158857 20Dual-Channel Safety Barriers Polarity: ~ / ~ Series 9002/22121+20.70.71.419.919.9- -20.120.1- -1.61.63.21501503006060120Pic. J 9002/22-032-300-111 158954 20121+29918158158- -177177- -1212248080160240240480Pic. M 9002/22-240-160-001 158948 20Dual-Channel Safety Barriers Signal Barrier Polarity: + / Signal Barrier Polarity: + Series 9002/33121+225.525.5- -0- -- -0- -- -282828000000Pic. I 9002/33-280-000-001 158913 20Dual-Channel Safety Barriers Star Barrier / Star Barrier Series 9002/77121+2 6492492- -545545- -9.39.39.3202040505090Pic. K 9002/77-093-040-001 158905 20121+2 67171- -82.182.1- -9.39.39.3150150300350350700Pic. K 9002/77-093-300-001 158897 20121+2 12111111- -126126- -1515151501503005605601130Pic. K 9002/77-150-300-001 158889 20121+2 24657657- -730730- -282828474794330330660Pic. K 9002/77-280-094-001 158877 202013-09-10KP00IIIen Safety Barriers 9 12. A2A2A2A2A2A2A2A2A2A2A2A2A2A2Safety BarriersSeries 9001 / 9002 / 9004Schematic for Dual-Channel Safety Barriers Series 9002Picture A Picture B Picture CPicture E Picture F Picture GPicture H Picture I Picture JPicture K Picture M Picture NSelection tableUN Rmax Safety data Schematic Order number Art. no. PSV V mA mWSingle-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity Series 9004/0112 30 16.8 50 840 Pic. A 9004/01-168-050-001 159060 2024 56 28 45 1260 Pic. A 9004/01-280-045-001 159082 2026 73 31.5 25 787.5 Pic. A 9004/01-315-025-001 159086 20Single-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity with Voltage Limitation Series 9004/5123 ... 27 20.6 50 1030 Pic. B 9004/51-206-050-001 159090 20SchematicSingle-Channel Safety Barriers with Electronic Current Limitation, Polarity +Picture A Picture BSafety Barriers09418E00 09419E00 09420E0009422E00 09423E00 09424E0009425E00 09426E00 09427E0009428E00 09430E00 11030E00Uo Io Po10013E00 10014E0010 2013-09-10KP00IIIen 13. A2A2A2A2A2A2A2A2A2A2A2A2A2A2Safety BarriersSeries 9001 / 9002 / 90042013-09-10KP00IIIen Safety Barriers 11 14. IsolatorsIsolatorsOverview of the System Components ISpac 14General ISpac 15Applications ISpac 16Ex i IsolatorsPower SupplyEx i Power Supply ISpac 9143 18TransmitterFrequency Transmitter ISpac 9146 20Vibration Transducer Supply Unit ISpac 9147 22Transmitter Supply Unit ISpac 9160 24Transmitter Supply Unit with Limit Value ISpac 9162 26Temperature Transmitter ISpac 9182 50Isolating RepeaterIsolating Repeater HART Input ISpac 9163 28mA-Isolating Repeater ISpac 9164 30Isolating Repeater ISpac 9165 32Isolating Repeater Loop Powered ISpac 9167 34Resistance Isolator ISpac 9180 4812 Isolators 2013-09-10KP00IIIen 15. A3ContentsEx i IsolatorsIsolating RepeaterFieldbus Isolating Repeater ISpac 9185 52Fibre Optics Fieldbus Isolating Repeater ISpac 9186 54Switching RepeaterSwitching Repeater ISpac 9170 36Relay ModuleI.S. Relay Module ISpac 9172 38Electronic Relay ISpac 9174 40Binary OutputBinary Output ISpac 9175 42Binary Output with Line Fault Transparency ISpac 9175 44Binary Output without Power Supply ISpac 9176 46Non - Ex i IsolatorsTransmitterTransmitter Supply Unit ISpac 9160 66Transmitter Supply Unit with Limit Value ISpac 9162 67mA-Isolating Repeater ISpac 9164 68Isolating Repeater ISpac 9165 69Isolating Repeater Loop Powered ISpac 9167 70Relay Module ISpac 9172 71Temperature Transmitter ISpac 9182 73System ComponentsSupply Module ISpac 9193 58HART Termination Board ISpac 9196 64HART-Multiplexer ISpac 9192 56pac-Bus ISpac 9194 60pac-Carrier ISpac 9195 62You will find further information on the Internet www.stahl.deEngineering ISpac2013-09-10KP00IIIen Isolators 13 16. A3GeneralOverview of the System ComponentsAssetManagementLevelControl LevelControl LevelZone 2 / Division 2Control LevelZone 1 / Division 1IsolatorsField Circuit Non-Ex i15801E00PLC / DCS PLC / DCSClassic / HARTmeld devicesClassic / HARTmeld devicesField Circuit Ex i14 2013-09-10KP00IIIen 17. A3A3A3A3A3A3A3A3A3A3A3A3A3A3GeneralA311748E00WebCode ISpacA> Versions Ex i and non-Ex i> All functions with 2 channels per module> Galvanic isolation between inputs, outputs andpower supply> Modules for DIN-rail installation or comfortablesystem integration via pac-Carrier> Detachable terminals available in screw terminaland spring clamp terminal versions> Extended temperature range -20 +70 C> Installation possible in Zone 2 resp. Div. 2> Most isolator versions can be used for applicationsaccording to functional safety SIL (IEC 61508)> Customer specific engineering byR. Stahls competence center> macros for easier planning andengineering availableATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex ix x x x x x Ex iinterfaceInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIIinterfacex x x Ex iinterfacex x x x x xTechnical DataMounting type on DIN-rail (NS35/15, NS35/7.5) or in pac-CarrierVersions - Screw terminals (standard)- Spring clamp terminalsRemovable, for wire cross-section 0.2 ... 2.5 mm2 or 2 x 1.5 mm2 flexible with orwithout splay protection or single-wireDegree of protectionEnclosure IP30Terminals IP20Ambient conditionsAmbient temperatureSingle device -20 ... +70 CGroup assembly -20 ... +60 CThe installation conditions affect the ambient temperature.Observe operating instructions.Storage temperature -40 ... +80 CGalvanic isolation Between inputs, outputs and power supplyVoltage range 18 ... 31.2 V DC / 96 ... 253 V AC (only 9170)Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs),Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)Ship approval DNVInstallation in Zone 2, Div. 2 and in the safe areaDimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations06812E00122 mm / 4.80 "X99 mm / 3.90 " Y114,5 mm / 4.51 "Dim. XScrew terminals 108 mm / 4.25 inSpring clamp terminals 128 mm / 5.04 inDim. YSeries 9143, 9185, 9192 35.2 mm / 1.39 inSeries 9146, 9147, 9160, 9162,17.6 mm / 0.69 in9163, 9165, 9167, 9170, 9172,9175, 9176, 9180, 9182, 91932013-09-10KP00IIIen Isolators 15 18. A3ISpacApplication of isolatorsSymbol Application ISpac Type Ex iIsolatorsSignal circuitNon Ex iSignal circuit06861E002-, 3-, 4-wire transmitters andcurrent sources91609162 (with limit value)Page 24Page 26Page 66Page 6706329E002-wire HART transmitter 91609162 (with limit value)Page 24Page 26Page 66Page 6707649E004-wire HART transmitter 91639164Page 28Page 30 Page 6806321E00I/P converter, HART control valve 91659167Page 32Page 34Page 69Page 7006331E00Resistance thermometers /Resistance temperature detectors(RTD)91829180Page 50Page 48Page 7206332E00Thermocouple 9182 Page 50 Page 7206333E00Contact, optocouple output 91709172Page 36Page 3806334E00NAMUR proximity switch 9170 Page 3606326E00Speed control,Flow measurement9146 Page 2006324E00Solenoid valve,LED indicating lamp, horn9175917691729174Page 42Page 46Page 38Page 40Page 7106327E00Fire & gas detectors 9167 Page 34 Page 7016 2013-09-10KP00IIIen 19. A3ISpacApplication of isolatorsSymbol Application ISpac Type Ex i06317E00Alarm contact 914691629182Signal circuitPage 20Page 26Page 50Non Ex iSignal circuitPage 67Page 7206330E00HART Multiplexer 91929196Page 56Page 6406328E00Modbus, Profibus DP,ServiceBus R.STAHL91859186Page 52Page 5406318E00Power supply ofintrinsically safe users9143 Page 1806892E00Vibration sensor 9147 Page 2215280E00Voltage source 9163 Page 28HARTEx iV2013-09-10KP00IIIen Isolators 17 20. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Ex i Power SupplyField Circuit Ex iSeries 9143Series 9143 A307673E00WebCode 9143A> For intrinsically safe power supply of3- or 4-wire transmittters and controllers> Intrinsically safe output [Ex ib] IIC/IIB> Stable output voltage> Galvanic isolation between output andpower supply> Power supply 24 V AC / DC or 85 ... 230 V AC> Compact designATEX / IECExZone 0 1 2 20 21 22Ex i interface x x x xInstallation in x*) x*)*) Restrictions see table explosion protectionSelection TableVersion Auxiliary power Ex i output Order number Art. no. PSNominal voltageUNMax. nominalcurrent INEx i power supplySeries 914324 V AC / DC 4.0 ... 5.6 V 160 mA 9143/10-065-200-10s 159820 299.5 ... 11.8 V 130 mA 9143/10-124-150-10s 159823 2912.5 ... 14.7 V 140 mA 9143/10-156-160-10s 159797 2914.6 ... 17.6 V 35 mA 9143/10-187-050-10s 159800 29115 / 230 V AC 4.0 ... 5.6 V 160 mA 9143/10-065-200-20s 159785 299.5 ... 11.8 V 130 mA 9143/10-124-150-20s 159791 2912.5 ... 14.7 V 140 mA 9143/10-156-160-20s 159829 2914.6 ... 17.6 V 35 mA 9143/10-187-050-20s 159832 29Note Other versions - see Automation CatalogueThe order code above is with screw type removable terminals.Technical DataExplosion protectionVersion 9143/10-...-...-10.24 V AC / DC9143/10-...-...-20.115 / 230 V ACGlobal (IECEx)Gas, dust and mining IECEx BVS 12.0009X IECEx BVS 12.0009XEx nA [ib Gb] IIC/IIB T4 Gc[Ex ib Db] IIIC[Ex ib Gb] IIC/IIB[Ex ib Db] IIIC[Ex ib Mb] I [Ex ib Mb] IEurope (ATEX)Gas, dust and mining BVS 05 ATEX E 152X BVS 05 ATEX E 152XE II 3 (2) G Ex nA [ib Gb] IIC/IIB T4 GcE II (2) D [Ex ib Db] IIICE II (2) G [Ex ib Gb] IIC/IIBE II (2) D [Ex ib Db] IIICE I (M2) [Ex ib Mb] I E I (M2) [Ex ib Mb] ICertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),Korea (KCs), Russia (GOST R), Serbia (SRPS), Belarus (operating authorisation)Ship approval DNV18 Isolators 2013-09-10KP00IIIen 21. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Ex i Power SupplyField Circuit Ex iSeries 9143Technical DataSafety dataVersion 9143/10-065-200-.0. 9143/10-124-150-.0. 9143/10-156-160-.0. 9143/10-187-050-.0.Max. voltage Uo 6.5 V 12.4 V 15.6 V 18.7 VMax. current Io 200 mA 150 mA 160 mA 50 mAMax. power Po 1.3 W 1.86 W 2.496 W 0.935 WFurther parametersVersion 9143/10-...-...-10.24 V AC / DC9143/10-...-...-20.115 / 230 V ACInstallation in Zone 2, 22 and in the safe area in Zone 22 and in the safe areaFurther information see respective certificate and operatinginstructionssee respective certificate and operatinginstructionsAuxiliary powerVersion 9143/10-...-...-10.24 V AC / DC9143/10-...-...-20.115 / 230 V ACRated voltage UN 24 V AC / DC 115 / 230 V ACVoltage range AC: 20 ... 28 VDC: 18 ... 35 V85 ... 230 V AC2013-09-10KP00IIIen Isolators 19 22. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Frequency TransmitterField Circuit Ex iSeries 9146Series 9146 A311024E00WebCode 9146A> Speed control of rotating partsin hazardous areas> Most compact device in its class,2 versions available: limit value switch, frequency/currentconversion, impulse divider functionwithin 17.6 mm width dual channel frequency/current conversionwithin 17.6 mm width> Line fault monitoring indicated by LED andfault-contact contact enables easy monitoringand prompt troubleshooting> Broad input frequency range 0.001 ... 20 kHzATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x xInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIISelection TableVersion Channels Output Limit value contact(per channel)Impulse output Order number Art. no. PSFrequency TransmitterField Circuit Ex iSeries 91461 0/4 ... 20 mA 2 NO / NC one NO selectable 9146/10-11-12s 159883 212 0/4 ... 20 mA without one NO selectable 9146/20-11-11s 159886 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.Technical DataExplosion protectionGlobal (IECEx)Gas, dust and mining IECEx BVS 13.0095XEx nA nC [ia Ga] IIC T4 Gc[Ex ia Da] IIIC[Ex ia Ma] IEurope (ATEX)Gas and dust BVS 05 ATEX E 0171 XE II 3 (1) G Ex nAc nCc [ia] IIC T4E II (1) D [Ex ia] IIICCertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),Russia (GOST R), Serbia (SRPS), USA (FM), Belarus (operating authorisation)Ship approval DNVSafety dataMax. voltage Uo 10.5 VMax. current Io 23.4 mAMax. power Po 61.4 mW (linear characteristic curve)20 Isolators 2013-09-10KP00IIIen 23. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Frequency TransmitterField Circuit Ex iSeries 9146Technical DataAuxiliary powerNominal voltage UN 24 V DCNominal current at UN, 20 mA1 channel 55 mA2 channels 75 mAEx i inputInput signal acc. to EN 60947-5-6 (NAMUR)Input frequency 0.001 ... 20000 HzOutput see selection tableError detection Ex i inputMessage of line fault andauxiliary power failure- contact (30 V / 100 mA) closed to earth in case of error- pac-Bus, potential-free contact (30 V / 100 mA)2013-09-10KP00IIIen Isolators 21 24. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Vibration Transducer Supply UnitSeries 9147Series 9147 A314793E00WebCode 9147A> For vibration, acceleration and speedsensors in 2- and 3-wire design> Space-saving dual-channel version> Signal frequencies up to 50 kHz> Easy setting by means of front-siderotary switch> Galvanic isolation between inputs andoutputs and auxiliary power> For use up to SIL 2 (IEC 61508)ATEX / IECExZone 0 1 2 20 21 22Ex i interface x x x x x xInstallation in x*) x*)*) Restrictions see table explosion protectionSelection tableVersion Channels Order number Art. no. PS WeightkgVibration transducersupply unitSeries 91471 9147/10-99-10s 212432 21 0.1502 9147/20-99-10s 212433 21 0.210Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.Technical DataExplosion protectionGlobal (IECEx)Gas, dust and mining IECEx BVS 12.0001 XEx nA [ia Ga] IIC T4 Gc[Ex ia Da] IIC[Ex ia Ma] IEurope (ATEX)Gas, dust and mining BVS 12 ATEX E 007 XE II 3 (1)G Ex nA [ia Ga] IIC T4 GcE II (1)D [Ex ia Da] IICE I (M1) [Ex ia Ma] ICertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), Canada (FMc), Kazakhstan (GOST K),Russia (GOST R), USA (FM)Ship approval DNVSafety dataMax. voltage Uo 26.3 VMax. current Io 88.3 mAMax. power Po 579 mWInsulation voltage Um 253 VFurther parametersInstallation in Zone 2Further information see respective certificate and operating instructions22 Isolators 2013-09-10KP00IIIen 25. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Vibration Transducer Supply UnitSeries 9147Technical DataElectrical dataVersion 1 channel9147/10-99-102 channels9147/20-99-10Auxiliary powerNominal voltage UN 24 V DC 24 V DCVoltage range 18 ... 31.2 V 18 ... 31.2 VResidual ripple within( 3.6 VSS ( 3.6 VSSvoltage rangeNominal current at UN1 channel 75 mA 2 channels 88 mAPower consumption at UN1 channel 1.8 W 2 channels 2.1 WPower dissipation at UN1 channel 1.4W 2 channels 1.8WPolarity reversal protection yes yesOperation indication LED green "PWR" LED green "PWR"Undervoltage monitoring yes (no faulty devices / output states) yes (no faulty devices / output states)Ex i inputInput resistance 10 kInput signal -20 ... -0.5 VFunctional range -24 ... 0 VOutput currentFor 3-wire operationFor 2-wire operationOutput10 mA at -21 V20 mA at -18 V2.6 / 4.3 / 7.9 mA at -10 VOutput signal -20 ... -0.5 VInternal resistance < 30 Load resistance1 channel > 2 k2 channels > 10 kSignal transmissionDelay input / output < 7 sPhase fluctuation < 0.6 % / periodTransferable frequency range 0 ... 50 kHzRipple at a load resistance of< 60 mVss10 kError limitsrelative to the measuring span -0.5 ... -20 VTemperature influence < 0.05 % / 10 KAuxiliary power influence < 0.05 %Load resistance influenceAt RL = 3 ... 10 k < 0.35 % / kDC transmission faultAt UN and 20 C < 0.5 %AC transmission faultAt UN and 20 CFrequency Phase fault Amplitude fault0 ... 200 Hz ( 0.5 1 %< 400 Hz ( 1.0 1 %> 600 Hz ( 1.5 1 %< 1 Hz ( 2.5 1 %< 10 kHz ( 25 +1 / -5 %< 20 kHz ( 50 +1 / -5 %< 50 kHz ( 125 -30 %Electromagnetic compatibility Tested to the following standards and regulations:EN 61326-1 Use in industrial environment2013-09-10KP00IIIen Isolators 23 26. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Transmitter Supply UnitField Circuit Ex iSeries 9160 Rev. FSeries 9160 Rev. F A309745E00WebCode 9160A> Suitable for 2-, 3-wires transmitter,2-wires HART transmitter and mA-sources(4-wires transmitter)> Intrinsically safe input [Ex ia] IIC> Galvanic isolation between input,output and power supply> Open-circuit and short-circuit monitoringand messaging for input and output(can be switched off)> For use up to SIL 2,special version up to SIL 3 (IEC 61508)> High accuracyATEX / IECExZone 0 1 2 20 21 22Ex i interface x x x x x xInstallation in x*) x*)*) Restrictions see table explosion protectionVariants with UL/FM approval for NEC on requestSelection TableOutput version(control)Channels Input Output A Output B SIL LFD* Order number Art. no. PS0/4 ... 20 mAactive / sourcewith HART1 0/4 ... 20 mA 0/4 ... 20 mA 2 no 9160/13-11-10s 214893 213 yes 9160/13-11-13s 214897 210/4 ... 20 mA 2 no 9160/19-11-10s 214901 210/4 ... 20 mAHigh Power0/4 ... 20 mA 2 yes 9160/14-11-11s 214899 212 0/4 ... 20 mA 0/4 ... 20 mA 0/4 ... 20 mA 2 no 9160/23-11-10s 214905 210/4 ... 20 mApassive / sinkwith HART1 0/4 ... 20 mA passive 2 no 9160/13-10-10s 214837 212 0/4 ... 20 mA passive passive 2 no 9160/23-10-10s 214903 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.* LFD - line fault diagnosisno - Device transmits line fault on the field side via the 4 ... 20 mA signal. Without LED / relay contact.yes - Device transmits line fault on the field side via the 4 ... 20 mA signal. With LED / relay contact.24 Isolators 2013-09-10KP00IIIen 27. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Transmitter Supply UnitField Circuit Ex iSeries 9160 Rev. FTechnical DataOutput version (control) 0/4 ... 20 mA active / source with HARTVersion 9160/xx-11-10 9160/xx-11-13 9160/14-11-11Explosion protectionGlobal (IECEx)Gas, dust and mining IECEx BVS 08.0050X IECEx BVS 08.0050XEx nA [ia Ga] IIC T4 Gc[Ex ia Da] IIIC[Ex ia Ma] IEx nA nC [ia Ga] IIC T4 Gc[Ex ia Da] IIIC[Ex ia Ma] IEurope (ATEX)Gas, dust and mining DMT 03 ATEX E 010 X DMT 03 ATEX E 010 XE II 3 (1) G Ex nA [ia Ga] IIC T4 GcE II (1) D [Ex ia Da] IIICE I (M1) [Ex ia Ma] IE II 3 (1) G Ex nA nC [ia Ga] IIC T4 GcE II (1) D [Ex ia Da] IIICE I (M1) [Ex ia Ma] ICertifications and certificatesCertificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS),Ukraine (TR), Belarus (operating athorisation)Ship approval DNVVersion 9160/xx-11-10 9160/xx-11-13 9160/14-11-11Safety dataMax. voltage Uo 27 V 27 V 27 VMax. current Io 88 mA 88 mA 112.5 mAMax. power Po 576 mW 576 mW 731 mWAuxiliary powerNominal voltage UN 24 V DC 24 V DC 24 V DCNominal current at UN, 20 mA1 channel 75 mA 95 mA 95 mA2 channels 115 mA Ex i inputInput signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HARTSupply voltage for transmitter ) 16 V at 20 mA(for 2-, 3-wire)) 16 V at 20 mA(for 2-, 3-wire)) 18 V at 20 mA(for 2-, 3-wire)OutputOutput signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HARTLoad resistance RL 0 ... 600 (terminal 1+ / 2- or 5+ / 6-)0 ... 379 (terminal 3+ / 2- or 4+ / 6-)(with internal 221 resistorfor HART)0 ... 600 (terminal 1+ / 2-)0 ... 379 (terminal 3+ / 2-)(with internal 221 resistorfor HART)0 ... 600 (terminal 1+ / 2- or 5+ / 6-)0 ... 379 (terminal 3+ / 2- or 4+ / 6-)(with internal 221 resistorfor HART)Output version (control) 0/4 ... 20 mA passive / sink with HARTVersion 9160/xx-10-10Explosion protectionGlobal (IECEx)Gas, dust and mining IECEx BVS 08.0050XEx nA nC [ia Ga] IIC T4 Gc[Ex ia Da] IIIC[Ex ia Ma] IEurope (ATEX)Gas, dust and mining DMT 03 ATEX E 010 XE II 3 (1) G Ex nA nC [ia Ga] IIC T4 GcE II (1) D [Ex ia Da] IIICE I (M1) [Ex ia Ma] ICertifications and certificatesCertificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS),Ukraine (TR), Belarus (operating athorisation)Ship approval DNVSafety dataMax. voltage Uo 27 VMax. current Io 88 mAMax. power Po 576 mWAuxiliary powerNominal voltage UN 24 V DCNominal current at UN, 20 mA1 channel 75 mA2 channels 115 mAEx i inputInput signal 0/4 ... 20 mA with HARTSupply voltage for transmitter ) 16 V at 20 mA (for 2-, 3-wire)OutputOutput signal Current sink, max. 30 V with HARTLoad resistance RL see data sheet2013-09-10KP00IIIen Isolators 25 28. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Transmitter Supply Unit with Limit ContactField Circuit Ex iSeries 9162Series 9162 A311025E00WebCode 9162A> Compact limit value switch with2 configurable limiting values and0/4 ... 20 mA or 4 ... 20 mA output> Suitable for 2-, 3-wire transmitter,2-wire HART transmitter and mA-sources> Intrinsically safe input [Ex ia] IIC> Open circuit / short-circuit monitoringand messaging> Variant for use up to SIL 2 (IEC 61508)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex ix x x x x x Ex iinterfaceInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) For restrictions, see Explosion protection tableClass I Class I Class II Class IIIinterfacex x x Ex iinterfacex x x x x xSelection TableVersion Channels Input Output Limit contact SIL Order number Art. no. PSTransmitter supply unit1 0/4 ... 20 mA0/4 ... 20 mA2 NO / NC 9162/13-11-12s 160120 21with limit contactwith HARTwith HARTSeries 91624 ... 20 mAwith HART4 ... 20 mAwith HART2 NO / NC 2 9162/13-11-14s 202460 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.Technical DataVersion 9162/13-11-12 9162/13-11-14Explosion protectionGlobal (IECEx)Gas and dust IECEx FMG 10.0020X IECEx FMG 10.0020XEx nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 C[Ex iaD]Ex nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 C[Ex iaD]Europe (ATEX)Gas and dust FM 06 ATEX 0008 X FM 06 ATEX 0008 XE II 3 (1) G Ex nAc nCc [ia] IIC T4E II (1) D [Ex ia] IIICE II 3 (1) G Ex nAc nCc [ia] IIC T4E II (1) D [Ex ia] IIICCertifications and certificatesCertificates IECEx, ATEX, India (PESO), Canada (cFM),Kazakhstan (GOST K), Korea (KTL),Russia (GOST R), Serbia (SRPS), USA (FM),Belarus (operating authorisation)IECEx, ATEX, Canada (cFM),Russia (GOST R), Serbia (SRPS), USA (FM),Belarus (operating authorisation)Ship approval DNV DNV26 Isolators 2013-09-10KP00IIIen 29. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Transmitter Supply Unit with Limit ContactField Circuit Ex iSeries 9162Technical DataVersion 9162/13-11-12 9162/13-11-14Safety dataMax. voltage Uo 27 V 27 VMax. current Io 87.9 mA 87.9 mAMax. power Po 574 mW 574 mWAuxiliary powerNominal voltage UN 24 V DC 24 V DCNominal current at83 mA 83 mAUN, 20 mAOutputOutput signal 0/4 ... 20 mA with HART 4 ... 20 mA with HARTLoad resistance RL 0 ... 600 (terminal 1+ / 2-) 0 ... 600 (terminal 1+ / 2-)Limiting valuesConfiguration using ISpac Wizard using ISpac WizardMessage 2 NO / NC 2 NO / NCSwitching voltage ( 30 V ( 30 VSwitching current( 100 mA ( 100 mA(resistive load)Error detection Ex i inputMessage of line fault andauxiliary power failure- contact (30 V / 100 mA) closed to earth in case of error- pac-Bus, potential-free contact (30 V / 100 mA)2013-09-10KP00IIIen Isolators 27 30. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Isolating Repeater InputSeries 9163 Rev. BSeries 9163 Rev. B A315281E00WebCode 9163A> Suitable for 4-wire HART transmittersand voltage sources> Intrinsically safe input [Ex ia] IIC> Galvanic Isolation between input,output and power supply> Open-circuit and short-circuit monitoring andmessaging (can be switched off)> For use up to SIL 2 (IEC 61508)ATEX / IECExZone 0 1 2 20 21 22Ex i interface x x x x x xInstallation in x*) x*)*) Restrictions see table explosion protectionVariants with UL/FM approval for NEC on requestSelection TableVersion Channels Input Output LFD* Order number Art. no. PSIsolating repeater1 0/4 ... 20 mA0/4 ... 20 mAno 9163/13-11-10s 214914 21inputwith HARTwith HARTSeries 9163passive (sink) no 9163/13-10-10s 214912 210/1 ... 5 V,0/2 ... 10 V0/4 ... 20 mA no 9163/11-81-10s 214910 212 0/4 ... 20 mAwith HART0/4 ... 20 mAwith HARTno 9163/23-11-10s 214920 21passive (sink) no 9163/23-10-10s 214918 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.* LFD - line fault diagnosis,no - The device transmits a line fault detected in the field circuit via the 4 ... 20 mA signal.Without LED / relay contact.28 Isolators 2013-09-10KP00IIIen 31. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Isolating Repeater InputSeries 9163 Rev. BTechnical DataVersion 9163/.3-1.-1.. 9163/11-81-10.Explosion protectionGlobal (IECEx)Gas and dustIECEx BVS 08.0050X IECEx BVS 08.0050XEx nA [ia Ga] IIC T4 Gc Ex nA [ia Ga] IIC T4 Gc[Ex ia Da] IIIC [Ex ia Da] IIIC[Ex ia Ma] I [Ex ia Ma] IEurope (ATEX)Gas and dust DMT 03 ATEX E010X DMT 03 ATEX E010XE II 3 (1) G Ex nA [ia Ga] IIC T4 GcE II (1) D [Ex ia Da] IIIC[Ex ia Ma] IE II 3 (1) G Ex nA [ia Ga] IIC T4 GcE II (1) D [Ex ia Da] IIIC[Ex ia Ma] ICertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO),Russia (GOST R), Serbia (SRPS),Ukraine (TR)IECEx, ATEXSafety dataMax. voltage Ui 30 V 30 VMax. current Ii 150 mA negligibleMax. power Pi 1000 mW negligibleMax. voltage Uo negligible 4.2 VMax. current Io negligible negligibleMax. power Po negligibleAuxiliary powerNominal voltage UN 24 V DC 24 V DCNominal current atUN, 20 mA1 channel 80 mA 80 mA2 channels 135 mA Input signal 0/4 ... 20 mA with HART 0 ... 5 V resp. 0 ... 10 VOutputOutput signal 9163/.3-11-10.: 0/4 ... 20 mA with HART9163/.3-10-10.: passive (sink)0/4 ... 20 mALoad resistance RL 0 ... 600 (terminal 1+/2- resp. 5+/6-)0 ... 479 (terminal 3+/2- resp. 4+/6-)(with internal 221 resistor for HART)0 ... 600 (terminal 1+/2- resp. 5+/6-)2013-09-10KP00IIIen Isolators 29 32. A3A3A3A3A3A3A3A3A3A3A3A3A3A3mA - Isolating RepeaterSeries 9164Series 9164 A308580E00WebCode 9164A> Interconnection of mA-sources andactive 2-wire inputs is possible> Perfect solution to integrate 4-wiretransmitters with 2 wire I/O-cards> Instrinsically safe input (Ex i) orincreased safety protection Ex e version> Bidirectional HART transmission 4 ... 20 mA> Galvanic isolation between input and outputATEX NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x xInstallation in x*) x*) x*) Installation in x*) x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIISelection TableVersion Channels Input Output Order number Art. no. PSmA - Isolating1 Ex i: 4 ... 20 mA HARTEx i: passive HART9164/13-20-06 224365 21repeater(sink)(sink)Series 9164Ex e: 4 ... 20 mAHART (sink)Ex i: passive HART(sink)9164/13-20-08 224364 21Technical DataVersion 9164/13-20-06 (Ex e Input) 9164/13-20-08 (Ex i Input)Explosion protectionEurope (ATEX)Gas and dust KEMA 04 ATEX 1236 X KEMA 04 ATEX 1298E II 2 (1) G Ex e mb [ia Ga] IIC T4 GbE II (1) D Ex e mb [ia Da] IIICE II 2 (1) G Ex ia [ia Ga] IIC T4 GbE II (1) D [Ex ia Da] IIICCertificates and approvalsCertificates ATEX ATEXShip approval DNV DNVSafety dataInput 4-wire transmitter-sideEx e connectionNominal voltage Un: 30 VNominal current In: 30 mANominal power Pn: 900 mW4-wire transmitter-sideEx i connectionOutput parameters: Uo, Io, Po = 0Max. voltage Ui: 30 VMax. current Ii: 150 mAMax. power Pi: 1 WOutput 2-wire outputOutput parameters: Uo, Io, Po = 0Max. voltage Ui: 30 VMax. current Ii: 150 mAMax. power Pi: 1 W2-wire outputOutput parameters: Uo, Io, Po = 0Max. voltage Ui: 30 VMax. current Ii: 150 mAMax. power Pi: 1 WAuxiliary power without withoutEx i / Ex e InputVersion passive (current sink) passive (current sink)Input signal 3.8 ... 20.5 mA with / wihout HART 3.8 ... 20.5 mA with / wihout HARTEx i outputVersion passive (current sink) passive (current sink)Output signal 3.6 ... 21 mA with HART 3.6 ... 21 mA with HART30 Isolators 2013-09-10KP00IIIen 33. A3A3A3A3A3A3A3A3A3A3A3A3A3A3mA - Isolating RepeaterSeries 9164Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations09432E0010 mm / 4.0" 3 672 mm / 2.83 " 12 mm / 0.47 "2013-09-10KP00IIIen Isolators 31 34. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Isolating RepeaterField Circuit Ex iSeries 9165Series 9165 A309734E00WebCode 9165A> For intrinsically safe operation of(HART)-control valves, i/p transmitters,displays> For HART output signals 0/4 ... 20 mA> Intrinsically safe output [Ex ia] IIC> Galvanic isolation between input,output and power supply> Open circuit / short-circuit monitoring andmessaging (can be switched off)> For use up to SIL 2 (IEC 61508)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x xInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protection:Class I Class I Class II Class IIISelection TableVersion Channels Input Ex i output signal LFD relay Order number Art. no. PSIsolating Repeater1 0/4 ... 20 mA0/4 ... 20 mAyes 9165/16-11-11s 201270 21Field Circuit Ex iwith HARTwith HARTSeries 9165no 9165/16-11-10s 207909 212 0/4 ... 20 mAwith HART0/4 ... 20 mAwith HARTyes 9165/26-11-11s 201272 21no 9165/26-11-10s 207910 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.LFD - Line fault diagnosticno - device transmits field-side line fault via 4 ... 20 mA signal via LEDyes - device transmits field-side line fault via 4 ... 20 mA signal via LED and relay contact32 Isolators 2013-09-10KP00IIIen 35. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Isolating RepeaterField Circuit Ex iSeries 9165Technical DataGlobal (IECEx)Gas and dust IECEx BVS 10.0011XEx nA nC [ia Ga] IIC T4 Gc[Ex ia Da] IIICEurope (ATEX)Gas and dust DMT 03 ATEX E 012 XE II 3 (1) G Ex nA nC [ia Ga] IIC T4 GcE II (1) D [Ex ia Da] IIICCertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K),Korea (KCs) only for 9165/16-11-11., Russia (GOST R), Serbia (SRPS), Ukraine (TR),USA (FM, UL*), Belarus (operating authorisation)* for UL approval - special version on requestShip approval DNVSafety dataMax. voltage Uo 25.6 VMax. current Io 96 mAMax. power Po 605 mWAuxiliary powerNominal voltage UN 24 V DCNominal current atUN, 20 mA1 channel 55 mA2 channels 90 mAInput signal 0/4 ... 20 mA with HARTEx i outputOutput signal 0/4 ... 20 mA with HARTConnectable load0 ... 800 resistanceFault detection Ex i outputSignalization of faulty lineand power supply failure- Contact (30 V / 100 mA) closed to ground in case of fault- pac-Bus, floating contact (30 V / 100 mA)(only for 9165/.6-11-11.)2013-09-10KP00IIIen Isolators 33 36. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Isolating Repeater Loop PoweredField Circuit Ex iSeries 9167Series 9167 A308577E00WebCode 9167A> For intrinsically safe operation of(HART)-control valves, i/p transmitters,displays, fire and gas detectors> For HART output signals 0/4 ... 20 mA> Intrinsically safe output [Ex ia] IIC> Galvanic isolation betweeninputs and outputs> Without power supply> Very low internal resistance> HART communication signal transmitting,bidirectionally> For use up to SIL 3 (IEC 61508)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x xInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIISelection TableVersion Channels Ex i output Uo / Io / Po max. load resistance RL Order number Art. no. PSIsolating Repeater1 15.7 V / 60 mA / 233 mW 360 9167/11-11-00s 160238 21Loop Powered FieldCircuit Ex iSeries 916725 V / 99 mA / 613 mW 800 9167/13-11-00s 160244 2118.8 V / 107 mA / 503 mW 590 9167/14-11-00s 160250 212 15.7 V / 60 mA / 233 mW 360 9167/21-11-00s 160241 2125 V / 99 mA / 613 mW 800 9167/23-11-00s 160247 2118.8 V / 107 mA / 503 mW 590 9167/24-11-00s 160253 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.34 Isolators 2013-09-10KP00IIIen 37. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Isolating Repeater Loop PoweredField Circuit Ex iSeries 9167Technical DataExplosion protectionGlobal (IECEx)Gas and dust IECEx BVS 11.0089XEx nA [ia Ga] IIC T4 Gc[Ex ia Da] IIICEurope (ATEX)Gas and dust BVS 04 ATEX E 082 XE II 3 (1) G Ex nA [ia Ga] IIC T4 GcE II (1) D [Ex ia Da] IIICCertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),Korea (KCs) only for 9167/14-11-00, Russia (GOST R), Serbia (SRPS), Ukraine (TR),USA (FM, UL), Belarus (operating authorisation)Ship approval DNVSafety dataVersion 9167/.1-11-00, max. 360 9167/.3-11-00, max. 800 9167/.4-11-00, max. 590 Max. voltage Uo 15.7 V 25 V 18.8 VMax. current Io 60 mA 99 mA 107 mAMax. power Po 233 mW 613 mW 503 mWAuxiliary power without without withoutInput signal IE 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HARTEx i outputOutput signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HARTFunction range 0 ... 40 mA 0 ... 40 mA 0 ... 40 mA2013-09-10KP00IIIen Isolators 35 38. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Switching RepeaterField Circuit Ex iSeries 9170Series 9170 A306528E00WebCode 9170A> For operation of contacts,proximity sensors (NAMUR), optocouplers> Intrinsically safe input [Ex ia] IIC> Galvanic isolation between input,output and auxiliary power> Open-circuit / short-circuit monitoring andmessaging (can be switched off)> Inversion of output signal can be adjusted> Transmission frequency up to 10 kHz> Can be used up to SIL 2 (relay output) orSIL 3 (electronic output) (IEC 61508)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex ix x x x x x Ex iinterfaceInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIIinterfacex x x Ex iinterfacex x x x x xSelection TableOutput version(control)Channels Power supply Output / channel LFD relay LFT Order number Art. no. PSSignal relay(125 V / 1 A)1 24 V DC 1 change-over contact no no 9170/11-11-13s 207471 212 change-over contacts yes no 9170/10-11-11s 160309 21120 ... 230 V AC 2 change-over contacts yes no 9170/10-11-21s 160318 212 24 V DC 1 change-over contact yes no 9170/20-10-11s 160290 212 NO yes no 9170/20-11-11s 160287 21no no 9170/21-11-13s 207472 21120 ... 230 V AC 1 change-over contact yes no 9170/20-10-21s 160300 212 NO yes no 9170/20-11-21s 160303 21Power relay(250 V / 4 A)1 24 V DC 1 change-over contact yes no 9170/10-12-11s 160312 21120 ... 230 V AC 1 change-over contact yes no 9170/10-12-21s 160321 212 change-over contacts yes no 9170/10-13-21s 160327 212 24 V DC 1 change-over contact yes no 9170/20-12-11s 160293 21120 ... 230 V AC 1 change-over contact yes no 9170/20-12-21s 160306 21Electronic(35 V / 50 mA)1 24 V DC 1 electronic output yes no 9170/11-14-11s 203287 21yes 9170/11-14-12s 203288 212 24 V DC 1 electronic output yes no 9170/21-14-11s 203152 21yes 9170/21-14-12s 203153 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.LFD - Line fault diagnosticno - device transmits line fault via LEDyes - device transmits line fault via LED and relay contactLFT - line fault transparency, device signals line fault on field side to the control directly via the signal output.36 Isolators 2013-09-10KP00IIIen 39. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Switching RepeaterField Circuit Ex iSeries 9170Technical DataVersion 24 V DC9170/.0-11-11.,9170/20-10-11.24 V DC9170/.1-11-13.,9170/.1-11-14.,9170/.1-14-12.24 V DC9170/.0-12-11.Explosion protectionGlobal (IECEx)Gas IECEx BVS 09.0041X IECEx BVS 09.0041X IECEx BVS 09.0041XEx nAc nCc [ia] IIC T4, [Ex ia] IIIC Ex nAc nCc [ia] IIC T4, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIICEurope (ATEX)Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X DMT 02 ATEX E195XE II 3 (1) G Ex nAc nCc [ia] IIC T4E II (1) D [Ex ia] IIICE II 3 (1) G Ex nAc nCc [ia] IIC T4E II (1) D [Ex ia] IIICE II (1) G [Ex ia] IICE II (1) D [Ex ia] IIICCertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO),India (PESO), Canada (CSA),Kazakhstan (GOST K),Russia (GOST R), Ukraine (TR),USA (FM, UL),Belarus (operating authorisation)IECEx, ATEX, India (PESO),Canada (CSA),Kazakhstan (GOST K),Russia (GOST R), USA (FM),Belarus (operating authorisation)IECEx, ATEX, Brazil (INMETRO),India (PESO), Canada (CSA),Kazakhstan (GOST K),Russia (GOST R), Serbia (SRPS),Ukraine (TR), USA (FM, UL),Belarus (operating authorisation)Ship approval DNV DNV DNVFurther parametersInstallation in Zone 2, Div. 2 andin the safe areain Zone 2, Div. 2 andin the safe areain safe areaFurther information see respective certificate andoperating instructionssee respective certificate andoperating instructionssee respective certificate andoperating instructionsVersion 120 ... 230 V AC9170/.0-11-21.,9170/20-10-21.120 ... 230 V AC9170/.0-12-21.,9170/.0-13-21.Explosion protectionGlobal (IECEx)Gas IECEx BVS 09.0041X IECEx BVS 09.0041X[Ex ia] IIC, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIICEurope (ATEX)Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195XE II (1) G [Ex ia] IICE II (1) D [Ex ia] IIICE II (1) G [Ex ia] IICE II (1) D [Ex ia] IIICCertifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), India (PESO),Canada (CSA), Kazakhstan (GOST K),Russia (GOST R), Serbia (SRPS), Ukraine (TR),USA (FM, UL), Belarus (operating authorisation)IECEx, ATEX, Brazil (INMETRO), India (PESO),Canada (CSA), Kazakhstan (GOST K), Korea (KCs)only for 9170/10-12-21., Russia (GOST R),Serbia (SRPS), USA (FM, UL),Belarus (operating authorisation)Ship approval DNV DNVFurther parametersInstallation in safe area in safe areaFurther information see respective certificate and operating instructions see respective certificate and operating instructionsSafety dataVersion 9170/10-..-..(1 channel)9170/11-..-..(1 channel)9170/20-..-..(2 channels)9170/21-..-..(2 channels)Inputs (channels individually)Max. voltage Uo 10.6 V 9.6 V 10.6 V 9.6 VMax. current Io 24 mA 10 mA 24 mA 10 mAMax. power Po 64 mW 24 mW 64 mW 24 mWInputs (2 channels parallel)Max. voltage Uo 10.6 V 9.6 VMax. current Io 48 mA 20 mAMax. power Po 128 mW 48 mWVersion 24 V DC9170/..-1.-1.120 ... 230 V AC9170/.0-1.-21.Auxiliary powerNominal voltage UN 24 V DC 120 ... 230 V ACInput signal acc. to EN 60947-5-6 (NAMUR) acc. to EN 60947-5-6 (NAMUR)Output see selection table see selection tableError detection Ex i inputMessage of line fault andauxiliary power failure- Contact in the output circuit (35 V / 50 mA) opens incase of fault (only at 9170/.1-14-12.)- contact (30 V / 100 mA), closed to ground incase of fault *)- pac-Bus, floating contact (30 V / 100 mA) *)*) not at 9170/.1-11-13.none2013-09-10KP00IIIen Isolators 37 40. A3A3A3A3A3A3A3A3A3A3A3A3A3A3I.S. Relay ModuleSeries 9172Series 9172 A308578E00WebCode 9172A> For binary signal and control circuits> Intrinsically safe inputs or outputs [Ex ia] IIC> Galvanic isolation betweeninputs and outputs> For use up to SIL 2 (IEC 61508)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x xInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) For restrictions, see Explosion Protection tableClass I Class I Class II Class IIISelection TableVersion Channels Input Output / channel Order number Art. no. PSI.S. relay module1 Ex i signal 1 change over contact9172/10-11-00s 160359 21Series 9172(250 V / 4 A)Ex i / I.S., 1 change over contact(125 V / 4 A, 30 V / 4 A)9172/12-11-00s 169651 21Non-Ex i signal Ex i / I.S., 1 change over contact(125 V / 4 A, 30 V / 4 A)9172/11-11-00s 160366 212 Ex i signal 1 change over contact(250 V / 4 A)9172/20-11-00s 160363 21Ex i / I.S., 1 change over contact(125 V / 4 A, 30 V / 4 A)9172/22-11-00s 169653 21Non-Ex i signal Ex i / I.S., 1 change over contact(125 V / 4 A, 30 V / 4 A)9172/21-11-00s 160369 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.Technical DataExplosion protectionGlobal (IECEx)Gas and dust IECEx BVS 09.0002XEx nA nC [ia Ga] IIC T4 Gc[Ex ia Da] IIICEurope (ATEX)Gas and dust BVS 04 ATEX E 097 XE II 3 (1) G Ex nA nC [ia] IIC T4E II (1) D [Ex iaD]Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)Ship approval DNV38 Isolators 2013-09-10KP00IIIen 41. A3A3A3A3A3A3A3A3A3A3A3A3A3A3I.S. Relay ModuleSeries 9172Technical DataSafety dataVersion 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00InputsMax. voltage Ui 30 V 30 VMax. current Ii 150 mA 150 mAMax. power Pi 1.3 W 1.3 WOutputs (contact) for connection of intrinsically safe circuits with:max. voltage Ui125 V AC125 V DCmax. current Ii4 A0.25 AInternal capacitance Ci negligible negligible negligibleInternal inductance Li negligible negligible negligibleIsolation voltage 253 V AC 253 V AC 253 V AC60 V DC0.3 A30 V DC4 AFurther parametersVersion 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00Installation in Zone 2, Div. 2 andin the safe area *)in Zone 2, Div. 2 andin the safe areain Zone 2, Div. 2 andin the safe area *)*) in Zone 2 max. contact loadcapacity 125 V / 4 A *) in Zone 2 max. contact loadcapacity 125 V / 4 AFurther information see respective certificate andoperating instructionssee respective certificate andoperating instructionssee respective certificate andoperating instructionsAuxiliary powerSupply without without withoutMax. power losses per0.4 W 0.4 W 0.4 WchannelInputInput signal Ex i non-Ex i Ex iSwitching signal 12 ... 30 V 12 ... 31.2 V 12 ... 30 VCurrent consumption < 16 mA at 12 V< 11 mA at 24 ... 30 V< 16 mA at 12 V< 11 mA at 24 ... 31.2 V< 16 mA at 12 V< 11 mA at 24 ... 30 VOutput see Selection Table see Selection Table see Selection TableAccessories and Spare PartsDesignation Description Art. no. PS WeightkgRelay modules forinstallation in Zone 1The modules 8510/122-06-6..-00 contain relay modules of Series 9172.If 8510 modules are installed in an enclosure of the degree of protection Ex e(e.g. Type 8150 or 8146), installation in Zone 1 is possible.165514 19 1.470165531 19 1.470200381 19 1.470220076 19 1.470Relay modules Type 9172 Modules Type 85109172/10-11-00s 8510/122-06-600-009172/20-11-00s 8510/122-06-601-009172/21-11-00s 8510/122-06-602-009172/22-11-00s 8510/122-06-604-002013-09-10KP00IIIen Isolators 39 42. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Electronic RelaySeries 9174Series 9174 A302133E00WebCode 9174A> Ex i control for switching Ex e loads> Maintenance-free and electronic switching> Compact design (width 12 mm)> Installation in Zone 1 together with I/O IS1 orFF Digital I/O coupler Series 9413> Galvanic isolation between input and outputATEXZone 0 1 2 20 21 22Ex i interface x x x xFor use in x x x xSelection TableVersion Channels Input Output Order number Art. no. PS WeightkgElectronic relaySeries 91741 Ex i Ex e, 48 V DC, 2 A 9174/10-14-00 212340 29 0.110Ex e, 250 V UC, 1 A 9174/10-15-00 212431 29 0.110Technical DataExplosion protectionEurope (ATEX)Gas and dust applied forEII 2 G Ex e mb [ib Gb] IIC T4 GbE II (2) D [Ex ib Db] IIICVersion 9174/10-14-10 9174/10-15-10Safety dataMax. voltage Ui 28 V 28 VMax. current Li 150 mA 150 mAMax. power Pi 780 mW 780 mWInternal capacitance Ci negligible negligibleInternal inductance Li negligible negligibleIsolation voltage 253 V 253 VRated operational currentEx e back-up fuse 2 A 3.15 AMax. power dissipation 0.85 W 1.6 WEx i inputSwitching level forON / OFFON 11 ... 28 V 11 ... 28 VOFF 0 ... 5 V 0 ... 5 VControl current < 15 mA < 15 mAEx e outputMax. voltage 48 V DC 250 V AC / DCMax. current 2 A 1 AMin. voltage 5 V DC 90 V AC / 40 V DCMin. current 2 mA 10 mAMax. switching frequency 300 Hz 300 Hz40 Isolators 2013-09-10KP00IIIen 43. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Electronic RelaySeries 9174Dimensional Drawings (All Dimensions in mm / inch) - Subject to Alterations14836E00108,8 mm / 4.28 "101,5 mm / 3.99 "90 mm / 3.54 "7,5 mm / 0.29 "92 mm / 3.62 "79 mm / 3.11 " 12,2 mm / 0.48 "2013-09-10KP00IIIen Isolators 41 44. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Binary OutputSeries 9175Series 9175 A309822E00WebCode 9175A> For intrinsically safe operation ofI.S. solenoid valves and indicators> Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC> Galvanic isolation between input,output and power supply> Open-circuit and short-circuit monitoring(can be switched off)> For use up to SIL 3 (IEC 61508)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex ix x x x x x Ex iinterfaceInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIIinterfacex x x Ex iinterfacex x x x x xSelection TableVersion Channels No-loadvoltage UoutMax. outputcurrent Iout maxInternalresistance RiOrder number Art. no. PSBinary outputSeries 91751 10 V 60 mA 150 9175/10-12-11s 160398 2117.5 V 45 mA 130 9175/10-14-11s 160410 2125 V 35 mA 250 9175/10-16-11s 160416 212 10 V 60 mA / 120 mA *) 150 / 75 *) 9175/20-12-11s 160404 2117.5 V 45 mA / 90 mA *) 130 / 65 *) 9175/20-14-11s 160413 2125 V 35 mA / 70 mA *) 250 / 125 *) 9175/20-16-11s 160419 21*) Parallel connection of the outputs possible; thus, doubling of the output current.Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.42 Isolators 2013-09-10KP00IIIen 45. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Binary OutputSeries 9175Technical DataExplosion protectionGlobal (IECEx)Gas IECEx BVS 10.0050XEx nAc nCc [ia] IIC T4[Ex ia] IIICEurope (ATEX)Gas and dust DMT 03 ATEX E 043 XE II 3 (1) G Ex nA nC [ia] IIC T4E II (1) D [Ex iaD]Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),Russia (GOST R), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)Ship approval DNVSafety dataVersion 9175/.0-12-11. 9175/.0-14-11. 9175/.0-16-11.Max. values per outputMax. voltage Uo 11.3 V 19.6 V 11.3 VMax. current Io 75 mA 150 / 60 mA 110 / 50 mAMax. power Po 210 mW 732 mW 760 mWAuxiliary powerNominal voltage UN 24 V DCNominal current(at UN, Iout max)80 mA / 140 mAInputVoltage for ON / OFFON 15 ... 31.2 VOFF 0 ... 5 VControl circuit < 5 mAEx i output see selection tableFault detection Ex i outputSignalization of faulty lineand power supply failure- Contact (30 V / 100 mA) closed to ground in case of fault- pac-Bus, floating contact (30 V / 100 mA)2013-09-10KP00IIIen Isolators 43 46. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Binary Output with Line Fault TransparencySeries 9175Series 9175 A307439E00WebCode 9175A> For intrinsically safe operation ofI.S. solenoid valves and indicators> Intrinsically safe output [Ex ia] IIC> Line fault transparency (LFT):line fault signalling directly via output onPLC / DCS> For use up to SIL 2 (IEC 61508)ATEX / IECExZone 0 1 2 20 21 22Ex i interface x x x x x xInstallation in x xSelection TableVersion Channels No-load voltageUoutMax. outputcurrent Iout maxInternalresistance RiOrder number Art. no. PSBinary outputwith line faulttransparencySeries 91751 10 V 60 mA 150 9175/10-12-12s 168456 2117.5 V 45 mA 130 9175/10-14-12s 168458 2125 V 35 mA 250 9175/10-16-12s 168460 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.44 Isolators 2013-09-10KP00IIIen 47. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Binary Output with Line Fault TransparencySeries 9175Technical DataExplosion protectionGlobal (IECEx)Gas IECEx BVS 10.0050XEx nAc nCc [ia] IIC T4[Ex ia] IIICEurope (ATEX)Gas and dust DMT 03 ATEX E 043 XE II 3 (1) G Ex nA nC [ia] IIC T4E II (1) D [Ex iaD]Certifications and certificatesCertificates IECEx, ATEX, India (PESO), Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR),Belarus (operating authorisation)Ship approval DNVMax. values per outputVersion 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12.Max. voltage Uo 11.3 V 19.6 V 11.3 VMax. current Io 110 / 50 mA 150 / 60 mA 75 mAMax. power Po 760 mW 732 mW 210 mWAuxiliary powerNominal voltage UN 24 V DC 24 V DC 24 V DCCurrent consumptionDevice draws its power from auxiliary power or signal cable as a function of its switching state.Version 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12.Switching state Input = Output Input = Output Input = OutputSwitching state OFFAuxiliary power ratedcurrent IN40 mA 35 mA 30 mASwitching state ONAuxiliary power ratedcurrent IN14 mA 14 mA 14 mASignal input ratedcurrent IN90 mA 80 mA 50 mAPower consumption 2.5 W 2.26 W 1.5 WPower loss 1.92 W 1.73 W 1.4 WInputVoltage for ON / OFFON 15 ... 31.2 VOFF 0 ... 5 VControl circuit < 5 mAEx i output see selection tableFault detection Ex i outputSignalization of faulty lineand power supply failure- contact on the signal input open in case of fault- pac-Bus, floating contact (30 V / 100 mA)2013-09-10KP00IIIen Isolators 45 48. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Binary Output without Power SupplySeries 9176Series 9176 A310495E00WebCode 9176A> For intrinsically safe operation ofEx i solenoid valves, indicators and horns> Power supply by control circuit, loop powered> Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC> Galvanic isolationbetween inputs and outputs> For use up to SIL 3 (IEC 61508)ATEX NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex ix x x x x x Ex iinterfaceInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIIinterfacex x x Ex iinterfacex x x x x xSelection TableVersion Channels No-load voltageUoutMax. outputcurrent Iout maxInternalresistance RiOrder number Art. no. PSBinary outputwithout power supplySeries 91761 10 V 60 mA 150 9176/10-12-00s 160452 2117.5 V 45 mA 130 9176/10-14-00s 160459 2125 V 29 mA 320 9176/10-15-00s 160472 2135 mA 250 9176/10-16-00s 160465 2143 mA 460 9176/10-17-00s 200546 212 10 V 60 mA / 120 mA *) 150 / 75 *) 9176/20-12-00s 160456 2117.5 V 45 mA / 90 mA *) 130 / 65 *) 9176/20-14-00s 160462 2125 V 29 mA / 58 mA *) 320 / 160 *) 9176/20-15-00s 165567 2135 mA / 70 mA *) 250 / 125 *) 9176/20-16-00s 160468 2143 mA / 86 mA *) 460 / 230 *) 9176/20-17-00s 171425 21*) Parallel connection of the outputs possible. Doubling of the output current.Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.46 Isolators 2013-09-10KP00IIIen 49. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Binary Output without Power SupplySeries 9176Technical DataExplosion protectionEurope (ATEX)Gas and dust BVS 04 ATEX E 075 XE II 3 (1) G Ex nA [ia] IIC T4E II (1) D [Ex iaD]Certifications and certificatesCertificates ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),Russia (GOST R), Ukraine (TR), USA (FM), USA (UL) - not for type 9176/..-17-00,Belarus (operating authorisation)Ship approval DNVSafety dataVersion 9176/..-12-... 9176/..-14-... 9176/..-15-... 9176/..-16-... 9176/..-17-...Max. values per outputMax. voltage Uo 11.3 V 19.6 V 27.6 V 27.6 V 27.6 VMax. current Io[Ex ia] 75 mA 150 mA 86.5 mA 110 mA 60 mA[Ex ib] 60 mA 44 mA 50 mA Max. power Po 210 mW 732 mW 596 mW 760 mW 415 mWAuxiliary power withoutInputVoltage for ON / OFFON 18 ... 31.2 VOFF 0 ... 5 VEx i output see selection table2013-09-10KP00IIIen Isolators 47 50. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Resistance IsolatorSeries 9180Series 9180 A311026E00WebCode 9180A> For intrinsically safe operartion of resistancethermometers or other resistance sensors> World-wide unique dual channel solution space saving, only 8.8 mm per channel> For 2-, 3- and 4-wire circuits> Resistance range from18 ... 391 or 180 ... 3910 > Intrinsically safe input [Ex ia] IIC> Galvanic isolation between input,output and power supplyATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x xInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIISelection TableVersion Channels Measuring range Order number Art. no. PSResistance isolator1 18 ... 391 (Pt100) 9180/10-77-11s 160491 21Series 9180180 ... 3910 (Pt1000) 9180/11-77-11s 160499 212 18 ... 391 (Pt100) 9180/20-77-11s 160494 21180 ... 3910 (Pt1000) 9180/21-77-11s 160502 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.Technical DataExplosion protectionGlobal (IECEx)Gas and dust IECEx BVS 10.0055XEx nAc nCc [ia] IIC T4[Ex ia] IIICEurope (ATEX)Gas and dust BVS 05 ATEX E 176 XE II 3 (1) G Ex nAc nCc [ia] IIC T4E II (1) D [Ex ia] IIICCertifications and certificatesVersion 9180/.0 9180/.1Certificates IECEx, ATEX, Brazil (INMETRO),India (PESO), Kazakhstan (GOST K),Korea (KCs) only for 9180/10-77-11.,Russia (GOST R), USA (FM),Belarus (operating authorisation)IECEx, ATEX, Brazil (INMETRO),India (PESO), Kazakhstan (GOST K),Russia (GOST R), USA (FM),Belarus (operating authorisation)Ship approval DNV DNV48 Isolators 2013-09-10KP00IIIen 51. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Resistance IsolatorSeries 9180Technical DataVersion 9180/.0 9180/.1Safety dataMax. voltage Uo 6.5 V 6.5 VMax. current Io 16.5 mA 16.5 mAMax. power Po 27 mW 27 mWEx i inputConnection type (no. of wires) 2-, 3-, 4-wire circuits 2-, 3-, 4-wire circuitsMeasuring range 18 ... 391 (Pt100) 180 ... 3910 (Pt1000)Middle resolution 10 m 100 m OutputOutput signal equals input signal (resistance)Response time (10 ... 90 %)< 10 msMultiplexer operationResponse time (Input = Output) < 1secError detection Ex i inputMessage of line fault andauxiliary power failure- contact (30 V / 100 mA) closed to earth in case of error- pac-Bus, potential-free contact (30 V / 100 mA)2013-09-10KP00IIIen Isolators 49 52. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Temperature TransmitterField Circuit Ex iSeries 9182Series 9182 A309746E00WebCode 9182A> For intrinsically safe operation ofthermocouples, resistance thermometers,resistance transmitters, mV-sources> One unit individually configurable for nearlyall temperature sensors> Intrinsically safe input [Ex ia] IIC> Galvanic isolation between input, output,power supply and configuration interface> Open-circuit and short-circuit monitoring andmessaging (can be switched off)> Simple configuration with PC or DIP-switchesATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex ix x x x x x Ex iinterfaceInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIIinterfacex x x Ex iinterfacex x x x x xSelection TableVersion Channels Output Limit value contact(per channel)SIL Order number Art. no. PSTemperaturetransmitterSeries 9182,field circuit Ex i1 0/4 ... 20 mAactive / sourcewithout 9182/10-51-11s 160546 212 9182/10-51-13s 201653 212 NO / NC 9182/10-51-12s 160549 212 9182/10-51-14s 201682 210/4 ... 20 mApassive / sinkwithout 2 9182/10-59-13s 201657 212 0/4 ... 20 mAactive / sourcewithout 9182/20-51-11s 160541 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.Signal duplication due to parallel connection of inputs of 9182/20-51-.. (dual channel).Further information see operating instruction.50 Isolators 2013-09-10KP00IIIen 53. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Temperature TransmitterField Circuit Ex iSeries 9182Technical DataExplosion protectionGlobal (IECEx)Gas IECEx BVS 09.0046XEx nAc nCc [ia] IIC T4[Ex ia] IIICEurope (ATEX)Gas and dust DMT 02 ATEX E 243 XE II 3 (1) G Ex nAc nCc [ia] IIC T4E II (1) D [Ex ia] IIICCertifications and certificatesVersion 9182/.0-51-1. 9182/10-5.-13, SIL 29182/10-51-14, SIL 2Certificates IECEx, ATEX, Brazil (INMETRO),Canada (CSA), Kazakhstan (GOST K),Korea (KTL) only for 9182/10-51-11,Russia (GOST R), Ukraine (TR),USA (FM, UL),Belarus (operating authorisation)IECEx, ATEX, Kazakhstan (GOST K),Russia (GOST R), Ukraine (TR),Belarus (operating athorisation)Ship approval DNV DNVSafety dataMax. voltage Uo 6.5 VMax. current Io 19.7 mAMax. power Po 32 mW (linear characteristic)Auxiliary powerNominal voltage UN 24 V DCNominal current at UN1 channel 70 mA2 channels 80 mAEx i Input The input parameters can be set via the parameterising software ISpac Wizard orDIP switch (only type 9182/.0-5.-11.).Input resistance thermometerTypes Pt 100, Pt 500, Pt 1000Ni 100, Ni 500, Ni 1000Type of circuit 2-, 3-, 4-wire circuitInput thermocouple Types B, E, J, K, N, R, S, T, L, U, XKInput resistance transmitterup to 100 k (RTD)Output(only for 9182/.0-51-1.)Output signal 0/4 ... 20 mA (configurable)Connectable loadresistance RL1 channel 0 ... 750 2 channels 0 ... 600 Limiting valuesMessage 2 NO / NC per channel(configurable using ISpac Wizard)Switching voltage ( 30 VSwitching current(resistive load)( 100 mAError detection Ex i inputMessage of line fault andauxiliary power failure- contact (30 V / 100 mA) closed to earth in case of error- pac-Bus, potential-free contact (30 V / 100 mA)2013-09-10KP00IIIen Isolators 51 54. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Fieldbus Isolating RepeaterSeries 9185Series 9185 A309812E00WebCode 9185A> For isolation between an intrinsically safe ornon-intrinsically safe RS 422 / RS 485 busand a non-intrinsically safe RS 232, RS 422,RS 485 interface> For operation of the intrinsically safeProfibus DP (RS 485 IS to PNO standard)> Intrinsically safe fieldbus RS 422, RS 485[Ex ib] IIC> Galvanic isolation betweenRS 422 / RS 485 (Ex i), RS 232, RS 422,RS 485 and power supply> Transmission speed adjustablebetween 1.2 kbit/s and 1.5 Mbit/s> Automatic setting of transmission speedfor Profibus DP> BitrefreshATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex ix x x x Ex iinterfaceInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIIinterfacex x Ex iinterfacex x x x x xSelection TableVersion Interfaces field area Interfaces safe area Order number Art. no. PSFieldbus isolatingRS-485 IS (PNO) RS-232, RS-422, RS-485 9185/11-35-10s 160587 21repeaterSeries 9185RS-422, RS-485 RS-232, RS-422, RS-485 9185/12-45-10s 160594 21Note The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.52 Isolators 2013-09-10KP00IIIen 55. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Fieldbus Isolating RepeaterSeries 9185Technical DataVersion 9185/11-35-10 9185/12-45-10Explosion protectionGlobal (IECEx)Gas and dust IECEx BVS 06.0004X IECEx BVS 06.0004XEx nAc [ib] IIC T4[Ex ib] IIICEx nAc IIC T4Europe (ATEX)Gas and dust DMT 02 ATEX E246X BVS 10 ATEX E 105 XE II (2) GD [EEx ib] IIC/IIB,E II 3 G EEx nA II T4E II 3G Ex nAc IIC T4Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO),India (PESO), Canada (CSA),Kazakhstan (GOST K), Russia (GOST R),Serbia (SRPS), Ukraine (TR), USA (FM),Belarus (operating authorisation)IECEx, ATEX, Brazil (INMETRO),India (PESO), Canada (CSA),Kazakhstan (GOST K), Russia (GOST R),Serbia (SRPS), Ukraine (TR), USA (FM),Belarus (operating authorisation)Ship approval DNV, ABS, RS DNV, ABS, RSVersion 9185/11-35-10 9185/12-45-10Safety dataMax. voltage Uo 3.73 V Max. current Io 149 mA Max. power Po 139 mW For connection RS 485 ISInsulation voltage 253 V Internal capacity Ci andnegligible inductivity LiMax. permissiblevoltage Ui 4.2 V Auxiliary powerNominal voltage UN 24 V UC 24 V UCNominal current (24 V) 80 mA 80 mAInterface field areaVersion RS 485 IS RS 485 / RS 422 (can be set)Level setting: RS 485 IS (PNO specification) and RS485 IS (R. STAHL specification)EIA RS 485, EIA RS 422Connections Sub-D socket X3, 9-pole Sub-D socket X3, 9-poleTransfer speed 1.2 kbit/s ... 1.5 bit/s 1.2 kbit/s ... 1.5 bit/sSettings fixes transmission speed or automatic detection> 9.6 kbit/s (only with Profibus DP)fixes transmission speed or automatic detection> 9.6 kbit/s (only with Profibus DP)Line length depends on transmission speed and cable depends on transmission speed and cableTerminating resistor to be set in external plug to be set in external plugData transmissionLED green "RxD3" LED green "RxD3"indicationInterface safe areaVersion RS 232, RS 422 (from Rev. B), RS 485 RS 232, RS 485 / RS 422 (can be set)Settings fixed transmission speed or automaticdetection > 9.6 kbit/s (only with Profibus DP)fixed transmission speed or automaticdetection > 9.6 kbit/s (only with Profibus DP)2013-09-10KP00IIIen Isolators 53 56. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Fibre Optics Fieldbus Isolating RepeaterSeries 9186Series 9186 A308579E00WebCode 9186A> Easy installation and mainetance due to: Intrinsically safe optical interface Intrinsically safe bus connection viaRS-485 IS (PNO)> High availability due to: Build-up of ring structures, redundantPoint-to-Point, line structures Integrated analysis of optical input signal Error message if critical levels of inputsignal reached> Transmission of Profibus DP, Modbus,HART on RS-485, R. STAHL Servicebus> 9186/12 Installation in Zone 1 and Zone 2 possible Fieldbus interface for intrinsically safeProfibus DP (PNO)> 9186/.5 Installation in Zone 2 possibleATEX NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 0 1 2 20 21 22 Division 1 2 1 2 1 29186/12-11-11:x x x x x x x x x 9186/12-11-11:Ex i interface9186/.5-..-..:Ex i interfacex x x 9186/.5-..-..:9186/12-11-11:Installation inx*) x*) x*) x*) x*) x*) x*) 9186/12-11-11:9186/.5-..-..:Installation inx*) x*) x*) x*) 9186/.5-..-..:*) Restrictions see table explosion protectionClass I Class I Class II Class IIIEx i interfacex x x x x xEx i interfacex x xInstallation inx*) x*) x*)Installation inx*) x*) x*)Selection TableVersion Installation in Network structure Order number Art. no. PSFibre optics fieldbusisolating repeaterSeries 9186Zone 1 Ring, point-to-point redundant, line 9186/12-11-11 160623 25Zone 2 andin the safe areaPoint-to-point, end of line 9186/25-12-11 160625 25Ring, point-to-point redundant, line 9186/15-12-11 160624 25Technical DataVersion 9186/12 9186/.5Installation in Zone 1 Zone 2 and in the safe areaExplosion protectionEurope (ATEX)Gas and dust BVS 06 ATEX E 145 X BVS 07 ATEX 068 XE II 2G (1) G Ex e mb ib [ia, op is] IIC T4E II (1) D [Ex iaD]E II (1) GD [Ex op is] IICE II 3 G Ex nA nC II T4Certifications and certificatesCertificates ATEX, Kazakhstan (GOST K),Russia (GOST R), USA (FM)ATEX, Canada (UL), Kazakhstan (GOST K),Russia (GOST R), USA (UL)Ship approval DNV DNVSafety dataMax. voltage Uo 3.7 V Max. current Io 148 mA Max. power Po 137 mW 54 Isolators 2013-09-10KP00IIIen 57. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Fibre Optics Fieldbus Isolating RepeaterSeries 9186Technical DataVersion 9186/12 9186/.5Installation in Zone 1 Zone 2 and in the safe areaSafety dataFor connection RS 485 ISMax. permissiblevoltage Ui 4.2 V Internal capacity Ci andinductivity Linegligible Ex i fault-contactMax. permissiblevoltage Ui24 V Max. permissiblecurrent Ii600 mA Internal capacity Ci andinductivity Linegligible Auxiliary powerNominal voltage UN 24 V DC 24 V DCNominal current (at UN) 67 mA 130 mAOptical interfaceProtocols protocol transparent for RS-485 interface protocol transparent for RS-485 interfaceNetwork topologies Ring topology, line topology,point-to-point connectionRing topology, line topology,point-to-point connectionRedundancy automatic switching in case of line fault automatic switching in case of line faultConnection ST, BFOC/2.5 connector ST, BFOC/2.5 connectorWavelength 850 nm 850 nmTransmission distance ( 2000 m ( 2000 mElectrical interfacesProtocols PROFIBUS DP, Modbus, HART,ServiceBus R.STAHL (IS1)PROFIBUS DP, Modbus, HART,ServiceBus R.STAHL (IS1)Version RS 485 IS (PNO) RS 485Connection Sub-D socket X1, 9-pole Sub-D socket X1, 9-poleBit rate 1.2 kbit/s ... 1.5 Mbit/s 9.6 kbit/s ... 1.5 Mbit/sFault controlPower supply failure Fault-contact is open Fault-contact is openTransmission level is good LED green and yellow "FO signal",fault-contact is closedLED green and yellow "FO signal",fault-contact is closedTransmission levelreduced (- 1.5 dBm)LED yellow "FO signal", fault-contact is open LED yellow "FO signal", fault-contact is openFibre breakage ortransmission level istoo low (- 3 dBm)LED red "FO ERR", fault-contact is open LED red "FO ERR", fault-contact is openSwitching capacity offault-contactsee Ex i values max. 60 V DC, 42 V, 1 AMechanical dataWeight approx. 200 g approx. 200 gMounting type on DIN rail, EN 50022 (NS35/15; NS35/7.5) on DIN rail, EN 50022 (NS35/15; NS35/7.5)Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations35,2 mm1.38 "99 mm / 3.89 "106 mm / 4.17 "35,2 mm1.38 "114,2 mm / 4.49 "106,7 mm / 4.20 "99 mm / 3.89 "106 mm / 4.17 "35,2 mm1.38 "114,2 mm / 4.49 "106,7 mm / 4.20 "06251E00 11335E00 11328E00126,5 mm / 4.98 "119 mm / 4.68 "99 mm / 3.89 "106 mm / 4.17 "9186/12-11-11 9186/15-12-11 9186/25-12-112013-09-10KP00IIIen Isolators 55 58. A3A3A3A3A3A3A3A3A3A3A3A3A3A3HART-MultiplexerSeries 9192Series 9192 A309730E00WebCode 9192A> Used for connection of up to32 HART capable field devices to anHART management system> Compatible to Cornerstone, AMS,FDM, Fieldcare, PDM, PRM etc. andFDT application> CommDTM for integration into FDT tools> Up to 128 HART-Multiplexer on onePC interface> Up to 3968 HART field devices> Galvanic isolation between power supply,RS 485 bus and HART channels> For use up to SIL 3 (IEC 61508)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIISelection TableVersion Channels Order number Art. no. PSHART-Multiplexer32 9192/32-10-10 160695 21Series 9192incl. 14-core connection cable for pac-Carrier Series 9195 or HART connection board Series 9196CommDTM available, download under the given WebCode 9192A56 Isolators 2013-09-10KP00IIIen 59. A3A3A3A3A3A3A3A3A3A3A3A3A3A3HART-MultiplexerSeries 9192Technical DataExplosion protectionGlobal (IECEx)Gas IECEx BVS 10.0042XEx nAc II T4Europe (ATEX)Gas BVS 03 E 213 XE II 3 G Ex nA II T4Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),USA (FM), Belarus (operating authorisation)Ship approval DNVAuxiliary powerNominal voltage UN 24 V DCNominal current (24 V) 55 mASystem configuration09237E00Field device interface (HART)Number of channels 16 or 32, setting via switchConnection Ribbon cable, 14-pole (inclusive)Signal HART FSKHART Specification HART Field Communication Protocal Rev. 7.1 (downwards compatible to Rev. 4.0);FSK Physical Layer Specification (Rev. 7.1)RS 485 interfaceNumber 1Connection Sub-D socket, 9-poleSignal RS 485Protocol compatible to Cornerstone, AMS, PDM, PRM, FDMNumber of HART-Multiplexerperbus segmentmaximum 312013-09-10KP00IIIen Isolators 57 60. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Supply ModuleSeries 9193Series 9193 A309814E00WebCode 9193A> Supply of 24 V DC power supply intothe pac-Bus> Supply current up to 4 A(for approx. 30 - 50 modules)> Single or redundant supply,decoupled via diodes, with LED indication> Exchangeable fuses for both supply circuits> Power supply failure and line fault messagingvia relay contacts> Different operating modes can be selectedvia DIP-switches(error signal and single / redundant supply)> Any installation on the pac-Bus(beginning, end, middle, both sides)ATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protectionClass I Class I Class II Class IIISelection TableVersion Supply Error messaging Order number Art. no. PSSupply module24 V / 4 A,Line fault and power supply failure 9193/20-11-11s 160717 21Series 9193primary + redundantNote The order numbers listed in the table are for devices equipped with screw-type terminals.For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with"k" for spring-type terminals.58 Isolators 2013-09-10KP00IIIen 61. A3A3A3A3A3A3A3A3A3A3A3A3A3A3Supply ModuleSeries 9193Technical DataExplosion protectionGlobal (IECEx)Gas IECEx BVS 10.0042XEx nAc nCc II T4Europe (ATEX)Gas BVS 03 E 213 XE II 3 G Ex nA nC II T4Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs),Russia (GOST R), USA (FM)Ship approval DNVInputPower supply 24 V DCInput range 18 ... 31.2 VRedundant supply yes, decoupled with diodesSafety fuse 5 x 20 mm; 2 x T 4.0 A; exchangeable for prim. and red. supplyOutput Supply into the pac-Bus24 V / maximum 4 AError messagePower fail PF Contact (35 V / 100 mA)Line fault LF Contact (35 V / 100 mA), closed in good conditions2013-09-10KP00IIIen Isolators 59 62. A3A3A3A3A3A3A3A3A3A3A3A3A3A3pac-BusSeries 9194Series 9194 A302710E00WebCode 9194A> Supply for approx. 40 modules per segment> Usabel for high and low profile DIN rails(NS35/15 and NS35/7.5)> Just snap on DIN rail without tools> Elements can be appended at any time> Potential free error messaging contactfor common error signal> Gold plated contacts forhighest contact safety> Low cost supply via terminals> Supply module with integrated replaceablefuses and redundant supply availableATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protection:Class I Class I Class II Class IIISelection TableVersion Picture Description Order number Art. no. PSpac-BusSeries 919409885E00pac-Bus single element,raster distance 17.6mm9194/31-17 160731 21Terminal setfor pac-Bus10374E005-pole, (set begin + end)with bridge for error message chain9194/50-01 160730 21Technical DataExplosion protectionGlobal (IECEx)Gas IECEx BVS 10.0042XEx nAc II T4Europe (ATEX)Gas BVS 03 E 213 XE II 3 G Ex nA II T4Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),USA (FM)Ship approval DNVAuxiliary powerMax. current 4 AConnection Screw terminals, 5-pole, maximum 1.5 mm2 or via supply module Series 9193Mounting type on DIN-railMounting orientation horizontal or vertical60 Isolators 2013-09-10KP00IIIen 63. A3A3A3A3A3A3A3A3A3A3A3A3A3A3pac-BusSeries 9194Dimensional Drawing (All Dimensions in mm / inches) - Subject to Alterations21 mm / 0.82 "09858E003,8 mm / 0.15 "17,6 mm / 0.69 "24,2 mm / 0.95 "22 mm / 0.87 "37 mm / 1.45 "15 mm / 0.59 "2013-09-10KP00IIIen Isolators 61 64. A3A3A3A3A3A3A3A3A3A3A3A3A3A3pac-CarrierSeries 9195Series 9195 A314224E00WebCode 9195A> pac-Carrier for 8 or 16 modules,up to 32 signals> All standard ISpac isolators can be used> Integration of Ex i and non-Ex i field circuitsin one carrier> Flexible engineering due to: direct allocation between I/O module andpac-Carrier simple connection tothe HART managemet system horizontal and vertical installation possible installation possible in Zone 2 and Div. 2> Easy and quick installation due to: customized system cables toautomation system installation of the isolators without tools installation of the carrier on DIN rail ormounting plate> Low out of service time of the system due to: redundant power supply withfault detection contact andexchangeable fuses very robust chassis proven bythe DNV approval for ship buildingATEX / IECEx NEC 505 NEC 506 NEC 500Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x xInstallation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)*) Restrictions see table explosion protection:Class I Class I Class II Class IIISelection TableVersion Number of slots Connection HART-Multiplexer Order number PSpac-Carrier8 no 9195/08A-...-... 27Series 91959192/32 9195/08H-...-... 2716 no 9195/16A-...-... 279192/32 9195/16H-...-... 27Customer specific versions for the following DCS: Yokogawa Centum VP, Yokogawa Pro-Safe-RS,Emerson Delta V, TRICONEX, Invensys, Honeywell, Siemens.Detailed information about the available pac carrier versions as well as technical documentation you maydownload from the internet at www.ispac.info. Engineering and shipment of new versions within 6 weeks.Technical DataExplosion protectionGlobal (IECEx)Gas IECEx BVS 10.0042XEx nAc nCc II T4Europe (ATEX)Gas BVS 03 ATEX E 213 XE II 3 G Ex nA nC II T4Certifications and certificatesCertificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),USA (FM)62 Isolators 2013-09-10KP00IIIen 65. A3A3A3A3A3A3A3A3A3A3A3A3A3A3pac-CarrierSeries 9195Technical DataAuxiliary powerNominal voltage UN 24 V DCRedundant supply yes, decoupled with diodesFuse 2 x TR5; T 2.0 A; exchangeable, for primary and redundant supplyConnection of field devicesNumber of channels 8, 16, 32System configuration10154E02HART interfacePLC or DCSSystem cable System cablepac Carrier 9195ipHART MuxEx iManagement SystemredundantConnection - via connection of automation systemsAssetHART RS485- via HART multiplexer 9192 (only at 9195/..H-...-...)Error messagePower fail PF Contact (35 V / 100 mA), closed in good conditionsDimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations09826E00155 mm / 6.10 "130 mm / 5.12 "*144 mm / 5.67 " 130 mm / 5.12 "Type 9195/08.-...-..., 8 slots09854E00155 mm / 6.10 "130 mm / 5.12 "*286 mm / 11.26 " 130 mm / 5.12 "Type 9195/16.-...-..., 16 slots* depending on Type, see Engineering Guide150 mm / 5.91 "*150 mm / 5.91 "*2013-09-10KP00IIIen Isolators 63 66. A3A3A3A3A3A3A3A3A3A3A3A3A3A3HART Termination BoardSeries 9196Series 9196 A307858E00WebCode 9196A>