SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo.
-
Upload
betty-kelley -
Category
Documents
-
view
215 -
download
0
Transcript of SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo.
SPS Synchrotron Light Monitor-BSR-Status
G. TRADE. Bravin, A. Goldblatt, F. Roncarolo
2SPS BSR Status, G. Trad 04 /02/2015
Content
System Description Location Components
Commissioning SR Intensity
Status
Outlook Batmon Readings
Summary
s
3
SystemDescription
Commissioning
Status
Outlook
SPSLayout
BSR
3SPS BSR Status, G. Trad 04 /02/2015
SR Monitor
Light Source
SR extraction
Optical Systems Detector
SystemDescription
Commissioning
Status
Outlook
4SPS BSR Status, G. Trad 04 /02/2015
• Critical wavelength emitted (even at the flat top energy 28 µm) is far from the detectable range
• Expected light results to be the Edge radiation
• Short distance between the two dipoles lead to interference phenomena
System DescriptionSystemDescription
Commissioning
Status
Outlook
5SPS BSR Status, G. Trad 04 /02/2015
integrated energy per turn over the detectable range in function of the energy
α ɣ12.8
• From E≈400 GeV the emitted light is comparable to the LHC emitted by the LHC undulator at 450 GeV
• Therefore it is reasonable to foresee an SR monitor at flattop energy in the SPS
SR Source SimulationSystemDescription
Commissioning
Status
Outlook
6SPS BSR Status, G. Trad 04 /02/2015
SystemDescription
Commissioning
Status
Outlook
s
80/ mm
96 mm
100
mm
SR Light
Towards optical system
Beam
axi
s
Mirr
or a
xis
View
Port
7SPS BSR Status, G. Trad 04 /02/2015
SystemDescription
Commissioning
Status
Outlook
8SPS BSR Status, G. Trad 04 /02/2015
Shielded Optical Table
Motorized Steering mirror
Extraction Mirror
SR Light
SystemDescription
Commissioning
Status
Outlook
9SPS BSR Status, G. Trad 04 /02/2015
SystemDescription
Commissioning
Status
Outlook
10SPS BSR Status, G. Trad 04 /02/2015
SR LightIntensified gated CCD(Motorized)
Filters : ND+ColorOn motorized wheel
Ocular Lens for zoom(motorized)
Apochromat Lens
SystemDescription
Commissioning
Status
Outlook
11SPS BSR Status, G. Trad 04 /02/2015
Calibration Target for magnification
Calculation
SystemDescription
Commissioning
Status
Outlook
12SPS BSR Status, G. Trad 04 /02/2015
Imaged SPS SR light for a bunch of 1011 protons over 4 SPS turnsalong the energy ramp.
SR Source MeasurementSystemDescription
Commissioning
Status
Outlook
13SPS BSR Status, G. Trad 04 /02/2015
measured
predictedobserved
Measured SR intensity integrated over the detector area
SR Source MeasurementSystemDescription
Commissioning
Status
Outlook
14SPS BSR Status, G. Trad 04 /02/2015
• Hardware Fully installed for a flattop measurement
• Software missing for a safe image acquisition with no expert tools
• Hardware missing for a continuous measurement along the ramp• (function generator for the gain control).
• If optimized acquisition could reach 30 frames per seconds (expert tools)
StatusSystem
Description
Commissioning
Status
Outlook
15SPS BSR Status, G. Trad 04 /02/2015
OUTLOOK
CROSS CALIBRATION WITH WS (s) FOR RESOLUTION MEASUREMENTS
17SPS BSR Status, G. Trad 04 /02/2015
Dispersion is important in the horizontal planeNeeded a good (delta p)/p knowledge
18SPS BSR Status, G. Trad 04 /02/2015
Possible Installation of a high frame rate digital camera (1000 fps)
SystemDescription
Commissioning
Status
Outlook
19SPS BSR Status, G. Trad 04 /02/2015
SPARE