Split System Air Conditioning - AC Direct

4
SS-339D 1/04 PRODUCT SPECIFICATIONS www.goodmanmfg.com High-Efficiency Split System Air Conditioning The CLQ outdoor condensing section is designed for ground-level or rooftop mount applications. Standard Features Louvered guard protects coil from damage and adds strength to the unit Bottom pan rails elevate the unit above slab Quiet-operating top discharge Totally enclosed and permanently lubricated 8- pole, 830-RPM PSC condenser motor High-efficiency Copeland scroll compressor Compressor sound blanket Copper tube, aluminum fin coil Brass suction and liquid shut-off valve with sweat connections Fully charged for 15’ [4.57m] of tubing length Factory-installed liquid line filter drier Air Handler and Coil Compatibilities CA and CH indoor coils U, UC, H and HT fan-less indoor coils for heat pump or cooling applications ARUF, ARPT and AEPT multi-position electric heat air handlers CLQ SERIES 14 SEER Cabinet Construction Polyester powder paint provides premium durability and improved UV protection Heavy gauge, zinc-clad, G90 galvanized steel When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds Accessories Standard room thermostat with 1-stage cool/1-stage heat (CHT18-60) Digital room thermostat with 1-stage cool/1-stage heat (CHTD18-60) Outdoor thermostats for staging/multi-staging indoor heating units (OT/EHR18-60) 2 to 5 Ton [7.00 kW to 17.56 kW]

Transcript of Split System Air Conditioning - AC Direct

Page 1: Split System Air Conditioning - AC Direct

SS-339D 1/04

PRODUCT SPECIFICATIONS

www.goodmanmfg.com

High-EfficiencySplit System

Air Conditioning

The CLQ outdoor condensing section is designed for ground-level or rooftop

mount applications.

Standard Features• Louvered guard protects coil from damage and

adds strength to the unit• Bottom pan rails elevate the unit above slab• Quiet-operating top discharge• Totally enclosed and permanently lubricated 8-

pole, 830-RPM PSC condenser motor• High-efficiency Copeland scroll compressor• Compressor sound blanket• Copper tube, aluminum fin coil• Brass suction and liquid shut-off valve with sweat

connections• Fully charged for 15’ [4.57m] of tubing length• Factory-installed liquid line filter drier

Air Handler and Coil Compatibilities• CA and CH indoor coils• U, UC, H and HT fan-less indoor coils for heat

pump or cooling applications• ARUF, ARPT and AEPT multi-position electric

heat air handlers

CLQ SERIES14 SEER

Cabinet Construction• Polyester powder paint provides premium durability

and improved UV protection• Heavy gauge, zinc-clad, G90 galvanized steel• When properly anchored, meets the 2001 Florida

Building Code unit integrity requirements for hurricane-type winds

Accessories• Standard room thermostat with 1-stage cool/1-stage

heat (CHT18-60)• Digital room thermostat with 1-stage cool/1-stage

heat (CHTD18-60)• Outdoor thermostats for staging/multi-staging

indoor heating units (OT/EHR18-60)

2 to 5 Ton[7.00 kW to 17.56 kW]

Page 2: Split System Air Conditioning - AC Direct

PRODUCT SPECIFICATIONS

2

Dimensional Data—CLQ42-60 Models

Dimensional Data—CLQ24-36 Models

Electrical Data

ModelCondenser

Type ApproximateShipping WeightLiquid Connection Suction Connection

CLQ24-1A 3⁄8” [9.5mm] 3⁄4” [19mm] Sweat 206 [93.4kg]

CLQ30-1A 3⁄8” [9.5mm] 3⁄4” [19mm] Sweat 250 [113.4kg]

CLQ36-1 3⁄8” [9.5mm] 7⁄8” [22.2mm] Sweat 260 [117.9kg]

CLQ42-1 3⁄8” [9.5mm] 7⁄8” [22.2mm] Sweat 269[122.0kg]

CLQ48-1 3⁄8” [9.5mm] 7⁄8” [22.2mm] Sweat 313[142.0kg]

CLQ60-1 3⁄8” [9.5mm] 7⁄8” [22.2mm] Sweat 337[152.9kg]

*Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require longer wire sizes.+May use fuses or HACR type Circuit Breakers of the same size as noted**With scroll compressor

Physical Data

Model Volts PH*Minimum

CircuitAmpacity

+MaximumOvercurrentProtection

Maximum Volts

Minimum Volts

Compressor Cond. Fan

RLA LRA FLA HP

**CLQ24-1A 208/230 1 13.1 20 253 197 9.6 45 1.1 1/6

**CLQ30-1A 208/230 1 17.4 30 253 197 13.0 63 1.1 1/6

**CLQ36-1 208/230 1 18.5 30 253 197 13.5 72.5 1.6 1⁄4

**CLQ42-1 208/230 1 23.0 40 253 197 17.1 88.0 1.6 1⁄4**CLQ48-1 208/230 1 24.1 40 253 197 18.0 104.0 1.6 1⁄4**CLQ60-1 208/230 1 28.6 50 253 197 21.6 137.0 1.6 1⁄4

Page 3: Split System Air Conditioning - AC Direct

3

PRODUCT SPECIFICATIONS

1) Seasonal Energy Efficiency Ratio2) Energy Efficiency Ratio @ 80 °F/67 °F Inside - 95 °F3) When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or what is specified on the piston kit chart

supplied with the indoor unit.4) XX of a model designates Electric Heat Quantity.5) EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with

B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay.

Model Evaporator Model Total BTUH [kw] Sensible BTUH [kw] (1) SEER (2) EER Decibels

CLQ24-1A

ARPT032/ARUF032ARPT042/ARUF042

AEPT030U31+GMNTE060-3

HT3236+GMNTE060-3H36F+GMNTE060-3

HT3236/U31/U32/UC32/H36F+EEP (5)HT4860/U47/UC47/H49F+EEP

CA*F030*2A+EEPCA*F048*2A+EEPCHPF030A2A+EEPCHPF048D2A+EEP

CA*F030*2A+GMNTE060-3CHPF030A2A+GMNTE060-3

2200022400230002200022000220002200023000210002200021000220002200022000

[6.4][6.6][6.7][6.4][6.4][6.4][6.4][6.7][6.1][6.4][6.1][6.4][6.4][6.4]

1630016500172001630016300163001630017000156001630015600163001630016300

[4.8][4.8][5.0][4.8][4.8][4.8][4.8][4.9][4.6][4.8][4.6][4.8][4.8][4.8]

13.514.015.014.514.514.513.514.013.514.013.514.014.514.5

12.513.013.813.513.513.512.513.012.513.012.513.013.513.5

74

CLQ30-1A

ARPT032/ARUF032AEPT030AEPT036

U31+GMNTE060-3U32/UC32+GMNTE060-3

H36F+GMNTE060-3HT4248+GMNTE060-3

U61/UC61+GMNTE100-4HT61+GMNTE100-4H61F+GMNTE100-4

HT3236/U31/U32/UC32/H36F+EEP (5)HT61/U61/UC61/U62/UC62/H61F+EEP

CA*F030*2A+EEPCA*F061*2A+EEPCHPF030A2A+EEPCHPF060D2A+EEP

CA*F030*2A+GMNTE060-3CHPF042B2A+GMNTE060-3CA*F061*2A+GMNTE100-4CHPF060D2A+GMNTE100-4

2700027000290002700027000270002700029000290002900027000290002700029000270002900027000270002900029000

[7.9][7.9][8.5][7.9][7.9][7.9][7.9][8.5][8.5][8.5][7.9][8.5][7.9][8.5][7.9][8.5][7.9][7.9][8.5][8.5]

1995019950214601995019950199501995021460214602146019950214601995021460199502146019950199502146021460

[5.8][5.8][6.3][5.8][5.8][5.8][5.8][6.3][6.3][6.3][5.8][6.3][5.8][6.3][5.8][6.3][5.8][5.8][6.3][6.3]

13.514.515.014.514.514.514.515.015.015.013.514.013.514.013.514.014.514.515.015.0

12.513.513.813.513.513.513.513.813.813.812.513.012.513.012.513.013.513.513.813.8

74

CLQ36-1

ARPT049/ARUF049AEPT036

U60/UC60+GMNTE100-4H60F+GMNTE100-4

HT4860+GMNTE100-4U61/UC61+GMNTE120-5U62/UC62+GMNTE120-5

H61F+GMNTE120-5HT61+GMNTE120-5

HT4860/U60/UC60/H60F+EEP (5)HT61/U61/UC61/U62/UC62/H61F+EEP

CA*X060*2A+EEPCA*X061*2A+EEPCHPF048D2A+EEPCHPF060D2A+EEP

CHPF060D2A+GMNTE100-4CHPF048D2A+GMNTE100-4CA*F061*2A+GMNTE120-5CHPF060D2A+GMNTE120-5

34400350003440034400344003500035000350003500034400360003340035000334003500034400344003500035000

[10.0][10.2][10.0][10.0][10.0][10.2][10.2][10.2][10.2][10.0][10.5][9.8][10.2][9.8][10.2][10.0][10.0][10.2][10.2]

24500250002450024500245002500025000250002500024500266002380025000238002500024500245002500025000

[7.2][7.3][7.2][7.2][7.2][7.3][7.3][7.3][7.3][7.2][7.8][7.0][7.3][7.0][7.3][7.2][7.2][7.3][7.3]

13.515.014.514.514.515.015.015.015.013.514.013.514.013.514.014.514.515.015.0

12.513.813.513.513.513.813.813.813.812.513.012.513.012.513.013.513.513.813.8

74

Performance Ratings

Page 4: Split System Air Conditioning - AC Direct

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.Copyright © 2003 Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. • Goodman products are made proudly in the USA.

4

PRODUCT SPECIFICATIONS

Performance Ratings (cont.)Model Evaporator Model Total BTUH [kw] Sensible BTUH [kw] (1) SEER (2) EER Decibels

CLQ42-1

ARPT049/ARUF049AEPT060

U60/UC60+GMNTE100-4H60F+GMNTE100-4

HT4860+GMNTE100-4U61/UC61+GMNTE120-5U62/UC62+GMNTE120-5

H61F+GMNTE120-5HT61+GMNTE120-5

HT4860/U60/UC60/H60F+EEP (5)HT61/U61/UC61/U62/UC62/H61F+EEP

CA*X060*2A+EEPCA*X061*2A+EEPCHPF048D2A+EEPCHPF060D2A+EEP

CA*F060*2A+GMNTE100-4CHPF048D2A+GMNTE100-4CA*F061*2A+GMNTE120-5CHPF060D2A+GMNTE120-5

40000410004000040000400004100041000410004100040000410004000041000400004100040000400004100041000

[11.7][12.0][11.7][11.7][11.7][12.0][12.0][12.0][12.0][11.7][12.0][11.7][12.0][11.7][12.0][11.7][11.7][12.0][12.0]

30000310003000030000300003100031000310003100030000310003000031000300003100030000300003100031000

[8.8][9.1][8.8][8.8][8.8][9.1][9.1][9.1][9.1][8.8][9.1][8.8][9.1][8.8][9.1][8.8][8.8][9.1][9.1]

13.515.014.514.514.515.015.015.015.013.514.013.514.013.514.014.514.515.015.0

12.513.813.513.513.513.813.813.813.812.513.012.513.012.513.013.513.513.813.8

76

CLQ48-1

ARPT049/ARUF049AEPT060

U60/UC60+GMNTE100-4H60F+GMNTE100-4

HT4860+GMNTE100-4U61/UC61+GMNTE120-5U62/UC62+GMNTE120-5

H61F+GMNTE120-5HT61+GMNTE120-5

HT4860/U60/UC60/H60F+EEP (5)HT61/U61/UC61/U62/UC62/H61F+EEP

CA*X060*2A+EEPCA*X061*2A+EEPCHPF048D2A+EEPCHPF060D2A+EEP

CA*F060*2A+GMNTE100-4CHPF048D2A+GMNTE100-4CA*F061*2A+GMNTE120-5CHPF060D2A+GMNTE120-5

44000450004400044000440004500045000450004500044000450004400045000440004500044000440004500045000

[12.9][13.2][12.9][12.9][12.9][13.2][13.2][13.2][13.2][12.9][13.2][12.9][13.2][12.9][13.2][12.9][12.9][13.2][13.2]

33000340003300033000330003400034000340003400033000340003300034000330003400033000330003400034000

[9.6][9.9][9.6][9.6][9.6][9.9][9.9][9.9][9.9][9.6][9.9][9.6][9.9][9.6][9.9][9.6][9.6][9.9][9.9]

13.514.514.014.014.014.514.514.514.513.514.013.514.013.514.014.014.014.514.5

12.513.513.013.013.013.513.513.513.512.513.012.513.012.513.013.013.013.513.5

76

CLQ60-1

ARPT061/ARUF060AEPT060

U61/UC61+GMNTE120-5U62/UC62+GMNTE120-5

H61F+GMNTE120-5HT61+GMNTE120-5

HT4860/U60/UC60/H60F+EEPHT61/U61/UC61/U62/UC62/H61F+EEP (5)

CA*X060*2A+EEPCA*X061*2A+EEPCHPF048D2A+EEPCHPF060D2A+EEP

CA*F061*2A+GMNTE120-5CHPF060D2A+GMNTE120-5

5500055000550005500055000550005400055000540005500054000550005500055000

[16.0][16.0][16.0][16.0][16.0][16.0][15.8][16.0][15.8][16.0][15.8][16.0][16.0][16.0]

3960039600396003960039600396003880039600388003960038800396003960039600

[11.6][11.6][11.6][11.6][11.6][11.6][11.4][11.6][11.4][11.6][11.4][11.6][11.6][11.6]

13.514.014.214.214.214.213.514.013.514.013.514.014.214.2

12.513.013.113.113.113.112.513.012.513.012.513.013.113.1

76

1) Seasonal Energy Efficiency Ratio2) Energy Efficiency Ratio @ 80 °F/67 °F Inside - 95 °F3) When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or what is specified on the piston kit chart

supplied with the indoor unit.4) XX of a model designates Electric Heat Quantity.5) EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with

B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay.