Product Specifications

Spectronic GENESYS 6 UV-Visible SpectrophotometerPart Number 335908 Series

Optical Design Split-beam, grating-based, dual detectors

Spectral Bandwidth 1.8 nm

Lamp Source Xenon

WavelengthRange 190 – 1100 nmAccuracy ± 1.0 nmRepeatability ± 0.5 nm

PhotometricRange - 0.1 – 3.0A; 0.3 – 125%T; ± 9999 CReadout Absorbance, Transmittance, ConcentrationAccuracy 0.5% or 0.005A, whichever is greater, up to 2A

Noise < 0.001A at 0A; < 0.002A at 2A, peak-to-peak at 340 nm

Drift < 0.001A/hour

Stray Light < 0.1%T at 220, 340, and 400 nm

Scanning Speed 10 – 2,000 nm/min

Slew Rate 11,000 nm/min

Scanning Sampling Interval 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

Cell Holder Automatic 6-cell changer

Graphic Display 320 x 240 pixel LCD, 96.5 x 71 mm (3.8" x 2.8")

Keypad Sealed membrane

SoftwareAbsorbance, Transmittance, ConcentrationStandard CurveAbsorbance RatioAbsorbance DifferenceKineticsSurvey Scan (full range scanning)

Scanning speed: 10 – 2,000 nm/minSampling interval: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

3-point NetMultiwavelengthPerformance ValidationCell CorrectionSmartStart™ program

Disc Drive 3 1/2" floppy; 1.44 Mb

Test Storage Up to 80 tests in non-volatile memory; floppy disk

Data Storage Floppy disk

Printer (optional) 40-column internal, graphical

Output Bi-directional RS232C (text only); parallel port output in HP PCL format (text and graphics)

Languages (user selectable) Software, printouts and operator’s manual: English, French, German, Spanish, Italian (user selectable)

Power Requirements Selected automatically; 100 – 240 Volts

Dimensions 330 W x 410 D x 235 H mm (13" x 16" x 9")

Weight 9.1 Kg (20.1 lb)

Warranty 1 year

Whether used in industries such as food and beverage,pharmaceutical, chemical orbiochemical research or production, you can count onthis full range scanning spectrophotometer to deliveraccurate, reliable results every time.

For over 50 years, researchers, quality controlchemists, teachers and students worldwidehave relied on Thermo Electron Corporationto provide UV-Visible spectrophotometers tomeet their specific applications and budgets.The Spectronic™ GENESYS™ 6 UV-Visiblespectrophotometer continues the tradition of performance, quality and value that havebecome our hallmark.

Proven Technology

UV-Visible Spectrophotometer

Spectronic GENESYS 6

Analyze • Detect • Measure • Control™

m o l e c u l a r s p e c t r o s c o p y

Chemical

Academic

Industrial QC

Pharmaceutical

Environmental

©2006 Thermo Electron Corporation. All rights reserved. All trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications,terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

BR51307_E 11/06M

Thermo Electron Scientific Instruments LLC, Madison, WI USA is ISO Certified.

Australia +61 2 8844 9500Austria +43 1 333 50340Belgium +32 2 482 30 30Canada +1 800 532 4752China +86 10 5850 3588

Denmark +45 70 23 62 60France +33 1 60 92 48 00Germany +49 6103 408 1014India +91 22 2778 1101Italy +39 02 950 591

Japan +81 45 453 9100Netherlands +31 76 587 98 88Scandinavia +46 8 556 468 00South Africa +27 11 570 1840Spain +34 91 657 4930

Switzerland +41 61 48784 00UK +44 1442 233555USA +1 800 532 4752

www.thermo.com

Page 2: Spectronic GENESYS 6 - thermofisher.cnthermofisher.cn/Resources/200802/productPDF_2486.pdf · Product Specifications Spectronic GENESYS 6 UV-Visible Spectrophotometer Part Number

Product Specifications

Spectronic GENESYS 6 UV-Visible SpectrophotometerPart Number 335908 Series

Optical Design Split-beam, grating-based, dual detectors

Spectral Bandwidth 1.8 nm

Lamp Source Xenon

WavelengthRange 190 – 1100 nmAccuracy ± 1.0 nmRepeatability ± 0.5 nm

PhotometricRange - 0.1 – 3.0A; 0.3 – 125%T; ± 9999 CReadout Absorbance, Transmittance, ConcentrationAccuracy 0.5% or 0.005A, whichever is greater, up to 2A

Noise < 0.001A at 0A; < 0.002A at 2A, peak-to-peak at 340 nm

Drift < 0.001A/hour

Stray Light < 0.1%T at 220, 340, and 400 nm

Scanning Speed 10 – 2,000 nm/min

Slew Rate 11,000 nm/min

Scanning Sampling Interval 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

Cell Holder Automatic 6-cell changer

Graphic Display 320 x 240 pixel LCD, 96.5 x 71 mm (3.8" x 2.8")

Keypad Sealed membrane

SoftwareAbsorbance, Transmittance, ConcentrationStandard CurveAbsorbance RatioAbsorbance DifferenceKineticsSurvey Scan (full range scanning)

Scanning speed: 10 – 2,000 nm/minSampling interval: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

3-point NetMultiwavelengthPerformance ValidationCell CorrectionSmartStart™ program

Disc Drive 3 1/2" floppy; 1.44 Mb

Test Storage Up to 80 tests in non-volatile memory; floppy disk

Data Storage Floppy disk

Printer (optional) 40-column internal, graphical

Output Bi-directional RS232C (text only); parallel port output in HP PCL format (text and graphics)

Languages (user selectable) Software, printouts and operator’s manual: English, French, German, Spanish, Italian (user selectable)

Power Requirements Selected automatically; 100 – 240 Volts

Dimensions 330 W x 410 D x 235 H mm (13" x 16" x 9")

Weight 9.1 Kg (20.1 lb)

Warranty 1 year

Whether used in industries such as food and beverage,pharmaceutical, chemical orbiochemical research or production, you can count onthis full range scanning spectrophotometer to deliveraccurate, reliable results every time.

For over 50 years, researchers, quality controlchemists, teachers and students worldwidehave relied on Thermo Electron Corporationto provide UV-Visible spectrophotometers tomeet their specific applications and budgets.The Spectronic™ GENESYS™ 6 UV-Visiblespectrophotometer continues the tradition of performance, quality and value that havebecome our hallmark.

Proven Technology

UV-Visible Spectrophotometer

Spectronic GENESYS 6

Analyze • Detect • Measure • Control™

m o l e c u l a r s p e c t r o s c o p y

Chemical

Academic

Industrial QC

Pharmaceutical

Environmental

©2006 Thermo Electron Corporation. All rights reserved. All trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications,terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

BR51307_E 11/06M

Thermo Electron Scientific Instruments LLC, Madison, WI USA is ISO Certified.

Australia +61 2 8844 9500Austria +43 1 333 50340Belgium +32 2 482 30 30Canada +1 800 532 4752China +86 10 5850 3588

Denmark +45 70 23 62 60France +33 1 60 92 48 00Germany +49 6103 408 1014India +91 22 2778 1101Italy +39 02 950 591

Japan +81 45 453 9100Netherlands +31 76 587 98 88Scandinavia +46 8 556 468 00South Africa +27 11 570 1840Spain +34 91 657 4930

Switzerland +41 61 48784 00UK +44 1442 233555USA +1 800 532 4752

www.thermo.com

Page 3: Spectronic GENESYS 6 - thermofisher.cnthermofisher.cn/Resources/200802/productPDF_2486.pdf · Product Specifications Spectronic GENESYS 6 UV-Visible Spectrophotometer Part Number

Product Specifications

Spectronic GENESYS 6 UV-Visible SpectrophotometerPart Number 335908 Series

Optical Design Split-beam, grating-based, dual detectors

Spectral Bandwidth 1.8 nm

Lamp Source Xenon

WavelengthRange 190 – 1100 nmAccuracy ± 1.0 nmRepeatability ± 0.5 nm

PhotometricRange - 0.1 – 3.0A; 0.3 – 125%T; ± 9999 CReadout Absorbance, Transmittance, ConcentrationAccuracy 0.5% or 0.005A, whichever is greater, up to 2A

Noise < 0.001A at 0A; < 0.002A at 2A, peak-to-peak at 340 nm

Drift < 0.001A/hour

Stray Light < 0.1%T at 220, 340, and 400 nm

Scanning Speed 10 – 2,000 nm/min

Slew Rate 11,000 nm/min

Scanning Sampling Interval 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

Cell Holder Automatic 6-cell changer

Graphic Display 320 x 240 pixel LCD, 96.5 x 71 mm (3.8" x 2.8")

Keypad Sealed membrane

SoftwareAbsorbance, Transmittance, ConcentrationStandard CurveAbsorbance RatioAbsorbance DifferenceKineticsSurvey Scan (full range scanning)

Scanning speed: 10 – 2,000 nm/minSampling interval: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

3-point NetMultiwavelengthPerformance ValidationCell CorrectionSmartStart™ program

Disc Drive 3 1/2" floppy; 1.44 Mb

Test Storage Up to 80 tests in non-volatile memory; floppy disk

Data Storage Floppy disk

Printer (optional) 40-column internal, graphical

Output Bi-directional RS232C (text only); parallel port output in HP PCL format (text and graphics)

Languages (user selectable) Software, printouts and operator’s manual: English, French, German, Spanish, Italian (user selectable)

Power Requirements Selected automatically; 100 – 240 Volts

Dimensions 330 W x 410 D x 235 H mm (13" x 16" x 9")

Weight 9.1 Kg (20.1 lb)

Warranty 1 year

Whether used in industries such as food and beverage,pharmaceutical, chemical orbiochemical research or production, you can count onthis full range scanning spectrophotometer to deliveraccurate, reliable results every time.

For over 50 years, researchers, quality controlchemists, teachers and students worldwidehave relied on Thermo Electron Corporationto provide UV-Visible spectrophotometers tomeet their specific applications and budgets.The Spectronic™ GENESYS™ 6 UV-Visiblespectrophotometer continues the tradition of performance, quality and value that havebecome our hallmark.

Proven Technology

UV-Visible Spectrophotometer

Spectronic GENESYS 6

Analyze • Detect • Measure • Control™

m o l e c u l a r s p e c t r o s c o p y

Chemical

Academic

Industrial QC

Pharmaceutical

Environmental

©2006 Thermo Electron Corporation. All rights reserved. All trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications,terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

BR51307_E 11/06M

Thermo Electron Scientific Instruments LLC, Madison, WI USA is ISO Certified.

Australia +61 2 8844 9500Austria +43 1 333 50340Belgium +32 2 482 30 30Canada +1 800 532 4752China +86 10 5850 3588

Denmark +45 70 23 62 60France +33 1 60 92 48 00Germany +49 6103 408 1014India +91 22 2778 1101Italy +39 02 950 591

Japan +81 45 453 9100Netherlands +31 76 587 98 88Scandinavia +46 8 556 468 00South Africa +27 11 570 1840Spain +34 91 657 4930

Switzerland +41 61 48784 00UK +44 1442 233555USA +1 800 532 4752

www.thermo.com

Page 4: Spectronic GENESYS 6 - thermofisher.cnthermofisher.cn/Resources/200802/productPDF_2486.pdf · Product Specifications Spectronic GENESYS 6 UV-Visible Spectrophotometer Part Number

Longpath Cell Holder

• Used for increased measurement sensitivity

• Available for rectangular or cylindrical cell

• Holds up to three 50 mm pathlength cells in 6-Position Cell Holder or one 100 mm pathlengthcell in Single Cell Holder Platform

Test Tube Holder

• Ideal for C.O.D. tubes and glasswarefrom reagent kits

• Holds test tubes up to 25 mm in diameter and up to 102 mm tall

Filter Holders

• Used to measure transmittance scans of filters and glass samples

• Spring-loaded and adjustable holders

Single Cell Holder Platform

• Holds one filter, test tube or longpathcell holder

• Recommended for microcells

Sipper System

• Optical glass or quartz flowcell

• Increased sample throughput

• Selectable tubing and pump time accommodates sample volumes from 2 – 15 mL

Spectronic GENESYS 6 UV-Visible Spectrophotometer

Powered to Perform, Priced to Surprise Scanning

• Records scans between 10 – 2,000 nm/min

• Runs with data intervals from 0.1 – 5 nm for greater scan detail

• Calculates 3-point net and area-under-the-curve

(a) Full-range scan of holmium oxide showing data manipulation options

(b) Segment of holmium oxide scan showing net height of the peak at 487 nm

Absorbance Ratio/Absorbance Difference

• Measures at two wavelengths, plus optional reference wavelength (for turbidity correction)

• Calculates concentrations in Absorbance Difference mode using user-defined factors

(c) Measurement of two DNA samples showing absorbance ratios. Values outside user set limits are flagged

(d) Calculation of DNA concentration using Absorbance Difference mode

Kinetics

• Measures and records reactions for up to 96 hours

• Calculates reaction rates in delta A per minute and displaysresults in concentration units of your choice

• Rescales and calculates rates over specified portions of the curve

(e) Assay of isocitrate dehydrogenase showing rate and concentration

Standard Curve

• Prepares and saves curves with up to 15 standards

• Includes 7 curve-fit options

• Offers option of pre-set or defined units

• Shows standard curve graph and curve-fit statistics

• Measures and displays up to 9999 samples; values outside userset limits are flagged

(f) Set-up screen for standard curve program showing curve-fit options

(g) Measurement of chlorine standards at 515 nm

Versatile Sampling Choices

Thermo Electron offers a complete rangeof accessories to address a variety ofsample types and laboratory needs.Complement your Spectronic GENESYS 6instrument with an easy-to-use accessoryto further increase productivity in your lab.

More Up-time

• Chemically resistant cover and sealed keypad keep yourinstrument running, regardless of accidental spills

• Reliable, proven technology minimizes costly repairs

• Long-lasting Xenon light source

More Bench Space

• Compact design gives you plenty of room for other lab equipment

• Built-in printer delivers high-quality printout of data and graphics without increasing system footprint

More Reliable Control

• High-resolution, backlit display makes readings easy to see

• User-friendly software

• Easy-to-use keypad simplifies setup and operation

• Built-in floppy disc drive and RS232C port provide accurate and safe data transfer

• Built-in or external printer prevents errors in transcription

More Sampling Options

• Built-in, 6-position auto cell changer increases samplethroughput

• Cuvette holders available for cells from 1 mm to 100 mmpathlength offer flexible sampling

• Simple sipper systems speed up sample introduction – available for Visible or UV-Visible applications

Advanced Design for High PerformanceDesigned for superior performance, the Spectronic GENESYS 6 spectrophotometeris the system you can count on to deliver accurate, reliable results.

Xenon Lamp

• Uses only one lamp for the entire 190 – 1100 nm wavelength range – fewer components mean less wear and tear

• Guaranteed for 2 x 108 flashes – equivalent to years of operation

• Flashes only when needed during measurements, resulting in extended lamp life

• Generates no heat – drift is virtually nonexistent

• Includes built-in UV and Visible emission lines for calibration purposes and to verify wavelength accuracy

• Provides high energy in UV region for more reliable results in life science applications

1.8 nm Spectral Bandwidth

• Provides high resolution without sacrificing energy

Dual-detector Split-beam Optical System

• Improves system stability by directing a portion of the light to a reference detector

Automatically Document Your ResultsThe Spectronic GENESYS 6 spectrophoto-meter can print to a built-in or external printer. Both options allow you to document all parameters including date, time, serial number, test name and final results – which is ideal for Good Laboratory Practice (GLP) requirements.

Graphical Internal Printer

• Compact design requires no additional bench space

• Uses thermal paper

External Printer

• Compatible with a wide variety of printers using HP PCL format

• Uses full-size paper

Built-in Automatic Cell Changer Saves TimeA 6-position cell holder (one position for a blank solution and five positions forsamples) makes obtaining accurate measurements easy. Simply press the RUN TEST key and the standard turret measures all positions automatically.• Runs automatically with all software

programs

• Always shows active position on display

• Removes easily for cleaning (no tools required)

• Includes unique Cell Correction software that automatically corrects for differences for up to six unmatchedcuvettes, including microcells

(c)

(d)

(a)

(b)

(e)

(h)

(i)

(f)

(g)

Printout of Photometric Accuracy,Wavelength Accuracy, and

Stray Light tests

The Spectronic GENESYS 6 spectrophotometer gives you all the featuresyou have come to expect from the Spectronic GENESYS product line,including a rugged, yet compact design, user-friendly software and unrivaled reliability. Best of all, this spectrophotometer provides all the functionality of an advanced instrument at an affordable price.

Let the System Do the Work for You With the Spectronic GENESYS 6 spectrophotometer, both routine and complextesting is easy. Its built-in software enables you to set up, save, then lock your testsfor added security. Simply program the test once – and all users in your laboratorycan follow the same procedure.

More Error-free Testing

• Program and save your test – Load and Run. The instrument will be set up thesame every time

• Lock your saved tests to prevent accidental alterations to your setup

More SavingsOur exclusive Cell Correction program option is available in all test modes. The program automatically “matches” up to six cuvettes – for up to 31 individualwavelengths AND a full scan. There is no need to purchase expensive matchedcuvettes-the system matches them for you.

More Productivity

• User-friendly software and easy-to-use keypad mean that anyone, regardless ofexperience, can run a test within minutes

• Auto cell changer allows you to load and measure several samples and then goon to another task

• Sample sipper systems increase sample throughput, eliminating the need for sev-eral expensive cells and for manually cleaning cells between each measurement

• Data output options (printer, RS232C or floppy disk) mean you no longer need tomanually write results in a paper notebook

Easy Data StorageThe instrument includes a built-in 3 1/2" floppy drive, so methods anddata can be saved directly to disk.Data is saved as an ASCII file – it can be easily transferred to a computer for data manipulation or archiving. In addition, methods can be transported to anotherSpectronic GENESYS 6 instrument.

Enhance Your Resultswith VISIONlite™ SoftwareVISIONlite software is a user-friendly package that offers a broad range of data handling, recording and processing capabilities. Full spectral scans,kinetics, single and multi-wavelength,and standard curve analyses can easily be performed with this software. In addition, increased data manipulation features allow you to get your results in the form you need.

Performance Validation

• Performs routine checks to verify instrument performance– Meets requirements from regulatory agencies– Time, date and serial number shown on printout– Software designed for use with Spectronic Standards and

internal standards

• Wavelength accuracy– Uses UV and visible wavelengths from internal Xenon lamp

OR– Uses Spectronic filter standards

• Photometric accuracy– Spectronic Standards, NTRMs or third-party standards required– Instrument reports actual results and a Pass/Fail indication based on

the tolerances that you set

• Stray light– Measures stray light at 220, 340 and 400 nm

• Noise– Measurements at 0 A and 2 A performed at 230 and 340 nm

• Diagnostics– Internal/external printer and RS232C output checked

(h) Selection of tests in the Performance Validation program

(i) Entry of standards in Photometric Accuracy test

Printout of chlorine standard curve showing

parameters, absorbancesof standards and

standard curve graph

Printout of full-range scan of holmium oxide withlabeled peaks and valleys

Page 5: Spectronic GENESYS 6 - thermofisher.cnthermofisher.cn/Resources/200802/productPDF_2486.pdf · Product Specifications Spectronic GENESYS 6 UV-Visible Spectrophotometer Part Number

Longpath Cell Holder

• Used for increased measurement sensitivity

• Available for rectangular or cylindrical cell

• Holds up to three 50 mm pathlength cells in 6-Position Cell Holder or one 100 mm pathlengthcell in Single Cell Holder Platform

Test Tube Holder

• Ideal for C.O.D. tubes and glasswarefrom reagent kits

• Holds test tubes up to 25 mm in diameter and up to 102 mm tall

Filter Holders

• Used to measure transmittance scans of filters and glass samples

• Spring-loaded and adjustable holders

Single Cell Holder Platform

• Holds one filter, test tube or longpathcell holder

• Recommended for microcells

Sipper System

• Optical glass or quartz flowcell

• Increased sample throughput

• Selectable tubing and pump time accommodates sample volumes from 2 – 15 mL

Spectronic GENESYS 6 UV-Visible Spectrophotometer

Powered to Perform, Priced to Surprise Scanning

• Records scans between 10 – 2,000 nm/min

• Runs with data intervals from 0.1 – 5 nm for greater scan detail

• Calculates 3-point net and area-under-the-curve

(a) Full-range scan of holmium oxide showing data manipulation options

(b) Segment of holmium oxide scan showing net height of the peak at 487 nm

Absorbance Ratio/Absorbance Difference

• Measures at two wavelengths, plus optional reference wavelength (for turbidity correction)

• Calculates concentrations in Absorbance Difference mode using user-defined factors

(c) Measurement of two DNA samples showing absorbance ratios. Values outside user set limits are flagged

(d) Calculation of DNA concentration using Absorbance Difference mode

Kinetics

• Measures and records reactions for up to 96 hours

• Calculates reaction rates in delta A per minute and displaysresults in concentration units of your choice

• Rescales and calculates rates over specified portions of the curve

(e) Assay of isocitrate dehydrogenase showing rate and concentration

Standard Curve

• Prepares and saves curves with up to 15 standards

• Includes 7 curve-fit options

• Offers option of pre-set or defined units

• Shows standard curve graph and curve-fit statistics

• Measures and displays up to 9999 samples; values outside userset limits are flagged

(f) Set-up screen for standard curve program showing curve-fit options

(g) Measurement of chlorine standards at 515 nm

Versatile Sampling Choices

Thermo Electron offers a complete rangeof accessories to address a variety ofsample types and laboratory needs.Complement your Spectronic GENESYS 6instrument with an easy-to-use accessoryto further increase productivity in your lab.

More Up-time

• Chemically resistant cover and sealed keypad keep yourinstrument running, regardless of accidental spills

• Reliable, proven technology minimizes costly repairs

• Long-lasting Xenon light source

More Bench Space

• Compact design gives you plenty of room for other lab equipment

• Built-in printer delivers high-quality printout of data and graphics without increasing system footprint

More Reliable Control

• High-resolution, backlit display makes readings easy to see

• User-friendly software

• Easy-to-use keypad simplifies setup and operation

• Built-in floppy disc drive and RS232C port provide accurate and safe data transfer

• Built-in or external printer prevents errors in transcription

More Sampling Options

• Built-in, 6-position auto cell changer increases samplethroughput

• Cuvette holders available for cells from 1 mm to 100 mmpathlength offer flexible sampling

• Simple sipper systems speed up sample introduction – available for Visible or UV-Visible applications

Advanced Design for High PerformanceDesigned for superior performance, the Spectronic GENESYS 6 spectrophotometeris the system you can count on to deliver accurate, reliable results.

Xenon Lamp

• Uses only one lamp for the entire 190 – 1100 nm wavelength range – fewer components mean less wear and tear

• Guaranteed for 2 x 108 flashes – equivalent to years of operation

• Flashes only when needed during measurements, resulting in extended lamp life

• Generates no heat – drift is virtually nonexistent

• Includes built-in UV and Visible emission lines for calibration purposes and to verify wavelength accuracy

• Provides high energy in UV region for more reliable results in life science applications

1.8 nm Spectral Bandwidth

• Provides high resolution without sacrificing energy

Dual-detector Split-beam Optical System

• Improves system stability by directing a portion of the light to a reference detector

Automatically Document Your ResultsThe Spectronic GENESYS 6 spectrophoto-meter can print to a built-in or external printer. Both options allow you to document all parameters including date, time, serial number, test name and final results – which is ideal for Good Laboratory Practice (GLP) requirements.

Graphical Internal Printer

• Compact design requires no additional bench space

• Uses thermal paper

External Printer

• Compatible with a wide variety of printers using HP PCL format

• Uses full-size paper

Built-in Automatic Cell Changer Saves TimeA 6-position cell holder (one position for a blank solution and five positions forsamples) makes obtaining accurate measurements easy. Simply press the RUN TEST key and the standard turret measures all positions automatically.• Runs automatically with all software

programs

• Always shows active position on display

• Removes easily for cleaning (no tools required)

• Includes unique Cell Correction software that automatically corrects for differences for up to six unmatchedcuvettes, including microcells

(c)

(d)

(a)

(b)

(e)

(h)

(i)

(f)

(g)

Printout of Photometric Accuracy,Wavelength Accuracy, and

Stray Light tests

The Spectronic GENESYS 6 spectrophotometer gives you all the featuresyou have come to expect from the Spectronic GENESYS product line,including a rugged, yet compact design, user-friendly software and unrivaled reliability. Best of all, this spectrophotometer provides all the functionality of an advanced instrument at an affordable price.

Let the System Do the Work for You With the Spectronic GENESYS 6 spectrophotometer, both routine and complextesting is easy. Its built-in software enables you to set up, save, then lock your testsfor added security. Simply program the test once – and all users in your laboratorycan follow the same procedure.

More Error-free Testing

• Program and save your test – Load and Run. The instrument will be set up thesame every time

• Lock your saved tests to prevent accidental alterations to your setup

More SavingsOur exclusive Cell Correction program option is available in all test modes. The program automatically “matches” up to six cuvettes – for up to 31 individualwavelengths AND a full scan. There is no need to purchase expensive matchedcuvettes-the system matches them for you.

More Productivity

• User-friendly software and easy-to-use keypad mean that anyone, regardless ofexperience, can run a test within minutes

• Auto cell changer allows you to load and measure several samples and then goon to another task

• Sample sipper systems increase sample throughput, eliminating the need for sev-eral expensive cells and for manually cleaning cells between each measurement

• Data output options (printer, RS232C or floppy disk) mean you no longer need tomanually write results in a paper notebook

Easy Data StorageThe instrument includes a built-in 3 1/2" floppy drive, so methods anddata can be saved directly to disk.Data is saved as an ASCII file – it can be easily transferred to a computer for data manipulation or archiving. In addition, methods can be transported to anotherSpectronic GENESYS 6 instrument.

Enhance Your Resultswith VISIONlite™ SoftwareVISIONlite software is a user-friendly package that offers a broad range of data handling, recording and processing capabilities. Full spectral scans,kinetics, single and multi-wavelength,and standard curve analyses can easily be performed with this software. In addition, increased data manipulation features allow you to get your results in the form you need.

Performance Validation

• Performs routine checks to verify instrument performance– Meets requirements from regulatory agencies– Time, date and serial number shown on printout– Software designed for use with Spectronic Standards and

internal standards

• Wavelength accuracy– Uses UV and visible wavelengths from internal Xenon lamp

OR– Uses Spectronic filter standards

• Photometric accuracy– Spectronic Standards, NTRMs or third-party standards required– Instrument reports actual results and a Pass/Fail indication based on

the tolerances that you set

• Stray light– Measures stray light at 220, 340 and 400 nm

• Noise– Measurements at 0 A and 2 A performed at 230 and 340 nm

• Diagnostics– Internal/external printer and RS232C output checked

(h) Selection of tests in the Performance Validation program

(i) Entry of standards in Photometric Accuracy test

Printout of chlorine standard curve showing

parameters, absorbancesof standards and

standard curve graph

Printout of full-range scan of holmium oxide withlabeled peaks and valleys

Page 6: Spectronic GENESYS 6 - thermofisher.cnthermofisher.cn/Resources/200802/productPDF_2486.pdf · Product Specifications Spectronic GENESYS 6 UV-Visible Spectrophotometer Part Number

Longpath Cell Holder

• Used for increased measurement sensitivity

• Available for rectangular or cylindrical cell

• Holds up to three 50 mm pathlength cells in 6-Position Cell Holder or one 100 mm pathlengthcell in Single Cell Holder Platform

Test Tube Holder

• Ideal for C.O.D. tubes and glasswarefrom reagent kits

• Holds test tubes up to 25 mm in diameter and up to 102 mm tall

Filter Holders

• Used to measure transmittance scans of filters and glass samples

• Spring-loaded and adjustable holders

Single Cell Holder Platform

• Holds one filter, test tube or longpathcell holder

• Recommended for microcells

Sipper System

• Optical glass or quartz flowcell

• Increased sample throughput

• Selectable tubing and pump time accommodates sample volumes from 2 – 15 mL

Spectronic GENESYS 6 UV-Visible Spectrophotometer

Powered to Perform, Priced to Surprise Scanning

• Records scans between 10 – 2,000 nm/min

• Runs with data intervals from 0.1 – 5 nm for greater scan detail

• Calculates 3-point net and area-under-the-curve

(a) Full-range scan of holmium oxide showing data manipulation options

(b) Segment of holmium oxide scan showing net height of the peak at 487 nm

Absorbance Ratio/Absorbance Difference

• Measures at two wavelengths, plus optional reference wavelength (for turbidity correction)

• Calculates concentrations in Absorbance Difference mode using user-defined factors

(c) Measurement of two DNA samples showing absorbance ratios. Values outside user set limits are flagged

(d) Calculation of DNA concentration using Absorbance Difference mode

Kinetics

• Measures and records reactions for up to 96 hours

• Calculates reaction rates in delta A per minute and displaysresults in concentration units of your choice

• Rescales and calculates rates over specified portions of the curve

(e) Assay of isocitrate dehydrogenase showing rate and concentration

Standard Curve

• Prepares and saves curves with up to 15 standards

• Includes 7 curve-fit options

• Offers option of pre-set or defined units

• Shows standard curve graph and curve-fit statistics

• Measures and displays up to 9999 samples; values outside userset limits are flagged

(f) Set-up screen for standard curve program showing curve-fit options

(g) Measurement of chlorine standards at 515 nm

Versatile Sampling Choices

Thermo Electron offers a complete rangeof accessories to address a variety ofsample types and laboratory needs.Complement your Spectronic GENESYS 6instrument with an easy-to-use accessoryto further increase productivity in your lab.

More Up-time

• Chemically resistant cover and sealed keypad keep yourinstrument running, regardless of accidental spills

• Reliable, proven technology minimizes costly repairs

• Long-lasting Xenon light source

More Bench Space

• Compact design gives you plenty of room for other lab equipment

• Built-in printer delivers high-quality printout of data and graphics without increasing system footprint

More Reliable Control

• High-resolution, backlit display makes readings easy to see

• User-friendly software

• Easy-to-use keypad simplifies setup and operation

• Built-in floppy disc drive and RS232C port provide accurate and safe data transfer

• Built-in or external printer prevents errors in transcription

More Sampling Options

• Built-in, 6-position auto cell changer increases samplethroughput

• Cuvette holders available for cells from 1 mm to 100 mmpathlength offer flexible sampling

• Simple sipper systems speed up sample introduction – available for Visible or UV-Visible applications

Advanced Design for High PerformanceDesigned for superior performance, the Spectronic GENESYS 6 spectrophotometeris the system you can count on to deliver accurate, reliable results.

Xenon Lamp

• Uses only one lamp for the entire 190 – 1100 nm wavelength range – fewer components mean less wear and tear

• Guaranteed for 2 x 108 flashes – equivalent to years of operation

• Flashes only when needed during measurements, resulting in extended lamp life

• Generates no heat – drift is virtually nonexistent

• Includes built-in UV and Visible emission lines for calibration purposes and to verify wavelength accuracy

• Provides high energy in UV region for more reliable results in life science applications

1.8 nm Spectral Bandwidth

• Provides high resolution without sacrificing energy

Dual-detector Split-beam Optical System

• Improves system stability by directing a portion of the light to a reference detector

Automatically Document Your ResultsThe Spectronic GENESYS 6 spectrophoto-meter can print to a built-in or external printer. Both options allow you to document all parameters including date, time, serial number, test name and final results – which is ideal for Good Laboratory Practice (GLP) requirements.

Graphical Internal Printer

• Compact design requires no additional bench space

• Uses thermal paper

External Printer

• Compatible with a wide variety of printers using HP PCL format

• Uses full-size paper

Built-in Automatic Cell Changer Saves TimeA 6-position cell holder (one position for a blank solution and five positions forsamples) makes obtaining accurate measurements easy. Simply press the RUN TEST key and the standard turret measures all positions automatically.• Runs automatically with all software

programs

• Always shows active position on display

• Removes easily for cleaning (no tools required)

• Includes unique Cell Correction software that automatically corrects for differences for up to six unmatchedcuvettes, including microcells

(c)

(d)

(a)

(b)

(e)

(h)

(i)

(f)

(g)

Printout of Photometric Accuracy,Wavelength Accuracy, and

Stray Light tests

The Spectronic GENESYS 6 spectrophotometer gives you all the featuresyou have come to expect from the Spectronic GENESYS product line,including a rugged, yet compact design, user-friendly software and unrivaled reliability. Best of all, this spectrophotometer provides all the functionality of an advanced instrument at an affordable price.

Let the System Do the Work for You With the Spectronic GENESYS 6 spectrophotometer, both routine and complextesting is easy. Its built-in software enables you to set up, save, then lock your testsfor added security. Simply program the test once – and all users in your laboratorycan follow the same procedure.

More Error-free Testing

• Program and save your test – Load and Run. The instrument will be set up thesame every time

• Lock your saved tests to prevent accidental alterations to your setup

More SavingsOur exclusive Cell Correction program option is available in all test modes. The program automatically “matches” up to six cuvettes – for up to 31 individualwavelengths AND a full scan. There is no need to purchase expensive matchedcuvettes-the system matches them for you.

More Productivity

• User-friendly software and easy-to-use keypad mean that anyone, regardless ofexperience, can run a test within minutes

• Auto cell changer allows you to load and measure several samples and then goon to another task

• Sample sipper systems increase sample throughput, eliminating the need for sev-eral expensive cells and for manually cleaning cells between each measurement

• Data output options (printer, RS232C or floppy disk) mean you no longer need tomanually write results in a paper notebook

Easy Data StorageThe instrument includes a built-in 3 1/2" floppy drive, so methods anddata can be saved directly to disk.Data is saved as an ASCII file – it can be easily transferred to a computer for data manipulation or archiving. In addition, methods can be transported to anotherSpectronic GENESYS 6 instrument.

Enhance Your Resultswith VISIONlite™ SoftwareVISIONlite software is a user-friendly package that offers a broad range of data handling, recording and processing capabilities. Full spectral scans,kinetics, single and multi-wavelength,and standard curve analyses can easily be performed with this software. In addition, increased data manipulation features allow you to get your results in the form you need.

Performance Validation

• Performs routine checks to verify instrument performance– Meets requirements from regulatory agencies– Time, date and serial number shown on printout– Software designed for use with Spectronic Standards and

internal standards

• Wavelength accuracy– Uses UV and visible wavelengths from internal Xenon lamp

OR– Uses Spectronic filter standards

• Photometric accuracy– Spectronic Standards, NTRMs or third-party standards required– Instrument reports actual results and a Pass/Fail indication based on

the tolerances that you set

• Stray light– Measures stray light at 220, 340 and 400 nm

• Noise– Measurements at 0 A and 2 A performed at 230 and 340 nm

• Diagnostics– Internal/external printer and RS232C output checked

(h) Selection of tests in the Performance Validation program

(i) Entry of standards in Photometric Accuracy test

Printout of chlorine standard curve showing

parameters, absorbancesof standards and

standard curve graph

Printout of full-range scan of holmium oxide withlabeled peaks and valleys

Page 7: Spectronic GENESYS 6 - thermofisher.cnthermofisher.cn/Resources/200802/productPDF_2486.pdf · Product Specifications Spectronic GENESYS 6 UV-Visible Spectrophotometer Part Number

Longpath Cell Holder

• Used for increased measurement sensitivity

• Available for rectangular or cylindrical cell

• Holds up to three 50 mm pathlength cells in 6-Position Cell Holder or one 100 mm pathlengthcell in Single Cell Holder Platform

Test Tube Holder

• Ideal for C.O.D. tubes and glasswarefrom reagent kits

• Holds test tubes up to 25 mm in diameter and up to 102 mm tall

Filter Holders

• Used to measure transmittance scans of filters and glass samples

• Spring-loaded and adjustable holders

Single Cell Holder Platform

• Holds one filter, test tube or longpathcell holder

• Recommended for microcells

Sipper System

• Optical glass or quartz flowcell

• Increased sample throughput

• Selectable tubing and pump time accommodates sample volumes from 2 – 15 mL

Spectronic GENESYS 6 UV-Visible Spectrophotometer

Powered to Perform, Priced to Surprise Scanning

• Records scans between 10 – 2,000 nm/min

• Runs with data intervals from 0.1 – 5 nm for greater scan detail

• Calculates 3-point net and area-under-the-curve

(a) Full-range scan of holmium oxide showing data manipulation options

(b) Segment of holmium oxide scan showing net height of the peak at 487 nm

Absorbance Ratio/Absorbance Difference

• Measures at two wavelengths, plus optional reference wavelength (for turbidity correction)

• Calculates concentrations in Absorbance Difference mode using user-defined factors

(c) Measurement of two DNA samples showing absorbance ratios. Values outside user set limits are flagged

(d) Calculation of DNA concentration using Absorbance Difference mode

Kinetics

• Measures and records reactions for up to 96 hours

• Calculates reaction rates in delta A per minute and displaysresults in concentration units of your choice

• Rescales and calculates rates over specified portions of the curve

(e) Assay of isocitrate dehydrogenase showing rate and concentration

Standard Curve

• Prepares and saves curves with up to 15 standards

• Includes 7 curve-fit options

• Offers option of pre-set or defined units

• Shows standard curve graph and curve-fit statistics

• Measures and displays up to 9999 samples; values outside userset limits are flagged

(f) Set-up screen for standard curve program showing curve-fit options

(g) Measurement of chlorine standards at 515 nm

Versatile Sampling Choices

Thermo Electron offers a complete rangeof accessories to address a variety ofsample types and laboratory needs.Complement your Spectronic GENESYS 6instrument with an easy-to-use accessoryto further increase productivity in your lab.

More Up-time

• Chemically resistant cover and sealed keypad keep yourinstrument running, regardless of accidental spills

• Reliable, proven technology minimizes costly repairs

• Long-lasting Xenon light source

More Bench Space

• Compact design gives you plenty of room for other lab equipment

• Built-in printer delivers high-quality printout of data and graphics without increasing system footprint

More Reliable Control

• High-resolution, backlit display makes readings easy to see

• User-friendly software

• Easy-to-use keypad simplifies setup and operation

• Built-in floppy disc drive and RS232C port provide accurate and safe data transfer

• Built-in or external printer prevents errors in transcription

More Sampling Options

• Built-in, 6-position auto cell changer increases samplethroughput

• Cuvette holders available for cells from 1 mm to 100 mmpathlength offer flexible sampling

• Simple sipper systems speed up sample introduction – available for Visible or UV-Visible applications

Advanced Design for High PerformanceDesigned for superior performance, the Spectronic GENESYS 6 spectrophotometeris the system you can count on to deliver accurate, reliable results.

Xenon Lamp

• Uses only one lamp for the entire 190 – 1100 nm wavelength range – fewer components mean less wear and tear

• Guaranteed for 2 x 108 flashes – equivalent to years of operation

• Flashes only when needed during measurements, resulting in extended lamp life

• Generates no heat – drift is virtually nonexistent

• Includes built-in UV and Visible emission lines for calibration purposes and to verify wavelength accuracy

• Provides high energy in UV region for more reliable results in life science applications

1.8 nm Spectral Bandwidth

• Provides high resolution without sacrificing energy

Dual-detector Split-beam Optical System

• Improves system stability by directing a portion of the light to a reference detector

Automatically Document Your ResultsThe Spectronic GENESYS 6 spectrophoto-meter can print to a built-in or external printer. Both options allow you to document all parameters including date, time, serial number, test name and final results – which is ideal for Good Laboratory Practice (GLP) requirements.

Graphical Internal Printer

• Compact design requires no additional bench space

• Uses thermal paper

External Printer

• Compatible with a wide variety of printers using HP PCL format

• Uses full-size paper

Built-in Automatic Cell Changer Saves TimeA 6-position cell holder (one position for a blank solution and five positions forsamples) makes obtaining accurate measurements easy. Simply press the RUN TEST key and the standard turret measures all positions automatically.• Runs automatically with all software

programs

• Always shows active position on display

• Removes easily for cleaning (no tools required)

• Includes unique Cell Correction software that automatically corrects for differences for up to six unmatchedcuvettes, including microcells

(c)

(d)

(a)

(b)

(e)

(h)

(i)

(f)

(g)

Printout of Photometric Accuracy,Wavelength Accuracy, and

Stray Light tests

The Spectronic GENESYS 6 spectrophotometer gives you all the featuresyou have come to expect from the Spectronic GENESYS product line,including a rugged, yet compact design, user-friendly software and unrivaled reliability. Best of all, this spectrophotometer provides all the functionality of an advanced instrument at an affordable price.

Let the System Do the Work for You With the Spectronic GENESYS 6 spectrophotometer, both routine and complextesting is easy. Its built-in software enables you to set up, save, then lock your testsfor added security. Simply program the test once – and all users in your laboratorycan follow the same procedure.

More Error-free Testing

• Program and save your test – Load and Run. The instrument will be set up thesame every time

• Lock your saved tests to prevent accidental alterations to your setup

More SavingsOur exclusive Cell Correction program option is available in all test modes. The program automatically “matches” up to six cuvettes – for up to 31 individualwavelengths AND a full scan. There is no need to purchase expensive matchedcuvettes-the system matches them for you.

More Productivity

• User-friendly software and easy-to-use keypad mean that anyone, regardless ofexperience, can run a test within minutes

• Auto cell changer allows you to load and measure several samples and then goon to another task

• Sample sipper systems increase sample throughput, eliminating the need for sev-eral expensive cells and for manually cleaning cells between each measurement

• Data output options (printer, RS232C or floppy disk) mean you no longer need tomanually write results in a paper notebook

Easy Data StorageThe instrument includes a built-in 3 1/2" floppy drive, so methods anddata can be saved directly to disk.Data is saved as an ASCII file – it can be easily transferred to a computer for data manipulation or archiving. In addition, methods can be transported to anotherSpectronic GENESYS 6 instrument.

Enhance Your Resultswith VISIONlite™ SoftwareVISIONlite software is a user-friendly package that offers a broad range of data handling, recording and processing capabilities. Full spectral scans,kinetics, single and multi-wavelength,and standard curve analyses can easily be performed with this software. In addition, increased data manipulation features allow you to get your results in the form you need.

Performance Validation

• Performs routine checks to verify instrument performance– Meets requirements from regulatory agencies– Time, date and serial number shown on printout– Software designed for use with Spectronic Standards and

internal standards

• Wavelength accuracy– Uses UV and visible wavelengths from internal Xenon lamp

OR– Uses Spectronic filter standards

• Photometric accuracy– Spectronic Standards, NTRMs or third-party standards required– Instrument reports actual results and a Pass/Fail indication based on

the tolerances that you set

• Stray light– Measures stray light at 220, 340 and 400 nm

• Noise– Measurements at 0 A and 2 A performed at 230 and 340 nm

• Diagnostics– Internal/external printer and RS232C output checked

(h) Selection of tests in the Performance Validation program

(i) Entry of standards in Photometric Accuracy test

Printout of chlorine standard curve showing

parameters, absorbancesof standards and

standard curve graph

Printout of full-range scan of holmium oxide withlabeled peaks and valleys

Page 8: Spectronic GENESYS 6 - thermofisher.cnthermofisher.cn/Resources/200802/productPDF_2486.pdf · Product Specifications Spectronic GENESYS 6 UV-Visible Spectrophotometer Part Number

Product Specifications

Spectronic GENESYS 6 UV-Visible SpectrophotometerPart Number 335908 Series

Optical Design Split-beam, grating-based, dual detectors

Spectral Bandwidth 1.8 nm

Lamp Source Xenon

WavelengthRange 190 – 1100 nmAccuracy ± 1.0 nmRepeatability ± 0.5 nm

PhotometricRange - 0.1 – 3.0A; 0.3 – 125%T; ± 9999 CReadout Absorbance, Transmittance, ConcentrationAccuracy 0.5% or 0.005A, whichever is greater, up to 2A

Noise < 0.001A at 0A; < 0.002A at 2A, peak-to-peak at 340 nm

Drift < 0.001A/hour

Stray Light < 0.1%T at 220, 340, and 400 nm

Scanning Speed 10 – 2,000 nm/min

Slew Rate 11,000 nm/min

Scanning Sampling Interval 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

Cell Holder Automatic 6-cell changer

Graphic Display 320 x 240 pixel LCD, 96.5 x 71 mm (3.8" x 2.8")

Keypad Sealed membrane

SoftwareAbsorbance, Transmittance, ConcentrationStandard CurveAbsorbance RatioAbsorbance DifferenceKineticsSurvey Scan (full range scanning)

Scanning speed: 10 – 2,000 nm/minSampling interval: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm

3-point NetMultiwavelengthPerformance ValidationCell CorrectionSmartStart™ program

Disc Drive 3 1/2" floppy; 1.44 Mb

Test Storage Up to 80 tests in non-volatile memory; floppy disk

Data Storage Floppy disk

Printer (optional) 40-column internal, graphical

Output Bi-directional RS232C (text only); parallel port output in HP PCL format (text and graphics)

Languages (user selectable) Software, printouts and operator’s manual: English, French, German, Spanish, Italian (user selectable)

Power Requirements Selected automatically; 100 – 240 Volts

Dimensions 330 W x 410 D x 235 H mm (13" x 16" x 9")

Weight 9.1 Kg (20.1 lb)

Warranty 1 year

Whether used in industries such as food and beverage,pharmaceutical, chemical orbiochemical research or production, you can count onthis full range scanning spectrophotometer to deliveraccurate, reliable results every time.

For over 50 years, researchers, quality controlchemists, teachers and students worldwidehave relied on Thermo Electron Corporationto provide UV-Visible spectrophotometers tomeet their specific applications and budgets.The Spectronic™ GENESYS™ 6 UV-Visiblespectrophotometer continues the tradition of performance, quality and value that havebecome our hallmark.

Proven Technology

UV-Visible Spectrophotometer

Spectronic GENESYS 6

Analyze • Detect • Measure • Control™

m o l e c u l a r s p e c t r o s c o p y

Chemical

Academic

Industrial QC

Pharmaceutical

Environmental

©2006 Thermo Electron Corporation. All rights reserved. All trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications,terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

BR51307_E 11/06M

Thermo Electron Scientific Instruments LLC, Madison, WI USA is ISO Certified.

Australia +61 2 8844 9500Austria +43 1 333 50340Belgium +32 2 482 30 30Canada +1 800 532 4752China +86 10 5850 3588

Denmark +45 70 23 62 60France +33 1 60 92 48 00Germany +49 6103 408 1014India +91 22 2778 1101Italy +39 02 950 591

Japan +81 45 453 9100Netherlands +31 76 587 98 88Scandinavia +46 8 556 468 00South Africa +27 11 570 1840Spain +34 91 657 4930

Switzerland +41 61 48784 00UK +44 1442 233555USA +1 800 532 4752

www.thermo.com