Spectra Flood Q40 - · PDF file3060 695 4680 540mm 190mm 340mm ... 131-136 Half CT Blue...

12
Order code: LEDJ284 - 40° Version LEDJ284N - 15° Version Spectra Flood Q40 Exterior Fixture User Manual

Transcript of Spectra Flood Q40 - · PDF file3060 695 4680 540mm 190mm 340mm ... 131-136 Half CT Blue...

Order code: LEDJ284 - 40° Version

LEDJ284N - 15° Version

Spectra Flood Q40 Exterior Fixture

User Manual

www.prolight.co.uk Spectra Flood Q40 User Manual 2

Safety advice

WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.

• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.

• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.

• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.

IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.

Donotendangeryourownsafetyandthesafetyofothers!

Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.

CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!

• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!

• Neverremovewarningorinformativelabelsfromtheunit.

• Donotopentheequipmentanddonotmodifytheunit.

• Donotconnectthisequipmenttoadimmerpack.

• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.

• Donotexposetoflammablesources,liquidsorgases.

• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.

• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.

• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.

• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.

• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.

• Onlyusefusesofsametypeandrating.

• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.

• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.

• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.

• WARRANTY:Oneyearfromdateofpurchase.

www.prolight.co.uk Spectra Flood Q40 User Manual 3

Product overview & technical specifications

Equippedwith40x10WRGBWLEDs,theQ40issuitableforilluminatinglargebuildings,eventspacesorstages.Theunitutilisesquad-colourLEDtechnologytoreproduceawidecolourspectrumfromrich,primarycoloursthroughtosubtlepasteltonesacrosseithera40°or15°beamwithaflat,evenfield.Designedforrentalandevents,theQ40featuresomegaquickreleasebrackets,PowerCONTRUE1connectorsforpowerinput/outputandalsofeaturesbothwiredandwirelessDMXbyW-DMXSweden.Theslimprofileofthefixtureisideallysuitedforloadingintoroadtrunksholdingmultipleunits.

• 40x10Wquad-colourLEDs(RGBW)

• Beamangle:40°-LEDJ28415°-LEDJ284N

• 40°-8,054Lux@2m(fullon)15°-57,800Lux@2m(fullon)

• 3kHzrefreshrate

•WirelessDMXcontrolbyW-DMXSweden

• DMXchannels:4,6or8selectable

• Staticcolour,colourchange,colourfadeandmaster/slavemodes

• 0-100%dimmingandvariablestrobe

• Suppliedwithinstallationbracketandquickreleaseomegaclamps

• 4pushbuttonmenuwithLCDdisplay

• PowerCONTRUE1input/output

• IPrated5-PinXLRinput/outputtrailingconnections

• Fancooled

Spectra Flood Q40

Specifications Spectra Flood Q40

Powerconsumption 410W

Powersupply 100~240V,50/60Hz

Dimensions 340x540x190mm

Weight 12kg

Ordercodes LEDJ284-40°VersionLEDJ284N-15°Version

0m 1m 2m 3m 4m 5m

40° - LuxFULL ONRGBW

32200612010800234015900

8054153426885863973

358068012002601760

40°

2010383673147993

129024543098.3635

0m 1m 2m 3m 4m 5m

15° - LuxFULL ONRGBW

231000437007660017400117000

578001090019100434029300

2574048508505193013000

15°

145002730479010907310

9250175030606954680

190mm540mm

340mm

IP54

www.prolight.co.uk Spectra Flood Q40 User Manual 4

01-Brackettighteningknobs

02-LCDdisplay

03-Functionbuttons

04-WirelessDMXantenna

05-PowerCONTRUE1input

06-PowerCONTRUE1output

07-IPrated5-PinXLRtrailinginput

08-IPrated5-PinXLRtrailingoutput

09-Fans

Inthebox:1 x fixture, 1 x power cable & 1 x user manual

Technical specifications

01 01

08

07

04 05 06 09 02 03

Underside mounting points:

www.prolight.co.uk Spectra Flood Q40 User Manual 5

Main Menu Sub Menu Options/Values Description

DMXControl

Address 001-512 DMXAddressSetting

Channels

4(4channelmode)

DMXChannelSetting6(6channelmode)

8(8channelmode)

W-DMXON

WirelessDMXSettingOFF

SlaveMode SlaveModeSetting

AutoMode AutoMode

Dimmer

Red 000-255

ManualDimmingModeGreen 000-255

Blue 000-255

White 000-255

Program Show

01C[--](Colour)-Seepage6forcolours

Built-inProgramsFlash[00-99]

02-14Speed[001-100]

Flash[00-99]

Settings

CurveSetting

Curves

Linear

DimmingCurvesSetting

SquareLaw

InvSquareLaw

S-Curve

DimmerSpeed

Fast

Smooth

Backlight-T

10S

BacklightTime

20S

30S

60S

ON

Backlight-L 01-10 BacklightBrightness

FactoryResetYES

FactoryResetNO

DMXFailOFF

DMXSignalFailureSettingHold

InformationTemperature FixtureTemperature

Software SoftwareVersion

Operating instructions

www.prolight.co.uk Spectra Flood Q40 User Manual 6

W-DMX settings:

ToenableW-DMX,pressthe“MENU”buttonandusethe“UP”and“DOWN”buttonstoselect“DMX Control”.Pressthe“UP”and“DOWN”buttonandusethe“UP”and“DOWN”buttonstoselect“W-DMX”.Nowusethe“UP”and“DOWN”buttonstoselect“ON”.

Pressthe“ENTER”buttontoconfirmthesetting.ThegreenLEDtotheleftofthedisplaywillflashindicatingitissearchingforasignal.

NowpairyourfixturewithyourW-DMXtransmitter.ThegreenLEDwillbecomestaticoncesucessfullypaired.

TodisableW-DMX,pressthe“MENU”buttonandusethe“UP”and“DOWN”buttonstoselect“DMX Control”.Pressthe“UP”and“DOWN”buttonandusethe“UP”and“DOWN”buttonstoselect“W-DMX”.Nowusethe“UP”and“DOWN” buttonstoselect“OFF”.Pressthe“ENTER”buttontoconfirmthesetting.

AlternativelywhenW-DMXisenabledpressandholdthe“MENU”button,thedisplaywillshow“W-DMX Lock Out”.OncethisiscompletetheW-DMXhasbeendisabled.

ThegreenLEDwillgoofftoconfirmW-DMXhasbeendisabled.

Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

Operating instructions

4 channel mode:

Channel Value Function

1 000-255 Red(0-100%)

2 000-255 Green(0-100%)

3 000-255 Blue(0-100%)

4 000-255 White(0-100%)

6 channel mode:

Channel Value Function

1 000-255 Masterdimmer(0-100%)

2 000-255 Red(0-100%)

3 000-255 Green(0-100%)

4 000-255 Blue(0-100%)

5 000-255 White(0-100%)

6 000-255 Strobe(slow-fast)

0 Blackout

1 Red

2 FlameRed

3 DeepGoldenAmber

4 MillenniumGold

5 GoldAmber

6 Orange

7 ChromeOrange

8 DeepAmber

9 SpringYellow

10 LimeGreen

11 JASGreen

12 FernGreen

13 MossGreen

14 PrimaryGreen

15 DarkGreen

16 Green

17 MediumBlue/Green

18 LightBlue

19 LighterBlue

20 SteelBlue

21 HalfCTBlue

22 FullCTBlue

23 StateBlue

24 DoubleCTBlue

25 MediumBlue

26 JustBlue

27 DeepBlue

28 Blue

29 CongoBlue

30 SurprisePink

31 FuchsuiaPink

32 FolliesPink

33 SpecialRosePink

34 Pink

35 MoroccanPink

36 WarmWhite

37 ColdWhite

38 White

Colour macros:

www.prolight.co.uk Spectra Flood Q40 User Manual 7

Value CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8

000

Masterdimmer(0-255)

Red(0-255)

Green(0-255)

Blue(0-255)

White(0-255)

Nofuntion Nofuntion Nofunction

001-018 Program1

Value Colour

Strobe(0-255)

000-010 Blackout

011-016 Red

017-022 FlameRed

023-028 DeepGoldenAmber

029-034 MillenniumGold

035-040 GoldAmber

041-046 Orange

047-052 ChromeOrange

053-058 DeepAmber

059-064 SpringYellow

065-070 LimeGreen

071-076 JASGreen

077-082 FernGreen

083-088 MossGreen

089-094 PrimaryGreen

095-100 DarkGreen

101-106 Green

107-112 MediumBlue/Green

113-118 LightBlue

119-124 LighterBlue

125-130 SteelBlue

131-136 HalfCTBlue

137-142 FullCTBlue

143-148 StateBlue

149-154 DoubleCTBlue

155-160 MediumBlue

161-166 JustBlue

167-172 DeepBlue

173-178 Blue

179-184 CongoBlue

185-190 SurprisePink

191-196 FuchsuiaPink

197-202 FolliesPink

203-208 SpecialRosePink

209-214 Pink

215-220 MoroccanPink

221-226 WarmWhite

227-232 ColdWhite

233-255 White

7 channel mode:

Operating instructions

www.prolight.co.uk Spectra Flood Q40 User Manual 8

Operating instructions

7 channel mode cont.:

Value CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8

019-037

Masterdimmer(0-255)

Red(0-255)

Green(0-255)

Blue(0-255)

White(0-255)

Program2

Speed(slow-fast)Strobe(0-255)

038-056 Program3

057-075 Program4

076-094 Program5

095-113 Program6

114-132 Program7

133-151 Program8

152-170 Program9

171-189 Program10

190-208 Program11

209-227 Program12

228-246 Program13

247-255 Program14

www.prolight.co.uk Spectra Flood Q40 User Manual 9

DMX setup

FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:

CABL10 – 2mCABL11 – 5mCABL12 – 10m

Setting the DMX address:

TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-512.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.

DMX 512:

DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).

DMX linking:

DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.

DATA cable (DMX cable) requirements (for DMX operation):

ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.

Also remember that DMX cable must be daisy chained and cannot be split.

www.prolight.co.uk Spectra Flood Q40 User Manual 10

Notice:

Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.

Special note:

Line termination:

Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.

Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.

Terminationreducessignaltransmissionproblemsandinterferance.itisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.

5-pin XLR (female)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

3-pin XLR (female)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

3-pin XLR (male)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)

5-pin XLR (male)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C

DMX setup

www.prolight.co.uk Spectra Flood Q40 User Manual 11

WEEE notice

Correct Disposal of this Product (Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European countries with separate collection systems)

Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedofwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.

Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.

Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk 12Spectra Flood Q40 User Manual