Spectra Flood Q40 - · PDF file3060 695 4680 540mm 190mm 340mm ... 131-136 Half CT Blue...
Transcript of Spectra Flood Q40 - · PDF file3060 695 4680 540mm 190mm 340mm ... 131-136 Half CT Blue...
Order code: LEDJ284 - 40° Version
LEDJ284N - 15° Version
Spectra Flood Q40 Exterior Fixture
User Manual
www.prolight.co.uk Spectra Flood Q40 User Manual 2
Safety advice
WARNINGFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodificationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment.
OPERATING DETERMINATIONSIfthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageandthewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION! TAKE CARE USING THIS EQUIPMENT!HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithothercables.Handlethepowercableandallmainsvoltageconnectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,asthiswillreducethesystem’slife.
• Donotexposetoflammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhenequipmentisnotinuseorbeforecleaning!Onlyhandlethepower-cablebytheplug.Neverpullouttheplugbypullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageisbetween100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedordamaged.Checktheequipmentandthepowercableperiodically.
• Iftheequipmentisdroppedordamaged,disconnectthemainspowersupplyimmediatelyandhaveaqualifiedengineerinspecttheequipmentbeforeoperatingagain.
• Ifyourproductfailstofunctioncorrectly,stopuseimmediately.Packtheunitsecurely(preferablyintheoriginalpackingmaterial),andreturnittoyourProLightdealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybecarriedoutbyaqualifiedtechnician.THISUNITCONTAINSNOUSERSERVICEABLEPARTS.
• Thislightingfixtureisforprofessionaluseonly-itisnotdesignedfororsuitableforhouseholduse.Theproductmustbeinstalledbyaqualifiedtechnicianinaccordancewithlocalterritoryregulations.Thesafetyoftheinstallationistheresponsibilityoftheinstaller.Thefixturepresentsrisksofsevereinjuryordeathduetofirehazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingtoEN62471.Donotviewthelightoutputwithopticalinstrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.
www.prolight.co.uk Spectra Flood Q40 User Manual 3
Product overview & technical specifications
Equippedwith40x10WRGBWLEDs,theQ40issuitableforilluminatinglargebuildings,eventspacesorstages.Theunitutilisesquad-colourLEDtechnologytoreproduceawidecolourspectrumfromrich,primarycoloursthroughtosubtlepasteltonesacrosseithera40°or15°beamwithaflat,evenfield.Designedforrentalandevents,theQ40featuresomegaquickreleasebrackets,PowerCONTRUE1connectorsforpowerinput/outputandalsofeaturesbothwiredandwirelessDMXbyW-DMXSweden.Theslimprofileofthefixtureisideallysuitedforloadingintoroadtrunksholdingmultipleunits.
• 40x10Wquad-colourLEDs(RGBW)
• Beamangle:40°-LEDJ28415°-LEDJ284N
• 40°-8,054Lux@2m(fullon)15°-57,800Lux@2m(fullon)
• 3kHzrefreshrate
•WirelessDMXcontrolbyW-DMXSweden
• DMXchannels:4,6or8selectable
• Staticcolour,colourchange,colourfadeandmaster/slavemodes
• 0-100%dimmingandvariablestrobe
• Suppliedwithinstallationbracketandquickreleaseomegaclamps
• 4pushbuttonmenuwithLCDdisplay
• PowerCONTRUE1input/output
• IPrated5-PinXLRinput/outputtrailingconnections
• Fancooled
Spectra Flood Q40
Specifications Spectra Flood Q40
Powerconsumption 410W
Powersupply 100~240V,50/60Hz
Dimensions 340x540x190mm
Weight 12kg
Ordercodes LEDJ284-40°VersionLEDJ284N-15°Version
0m 1m 2m 3m 4m 5m
40° - LuxFULL ONRGBW
32200612010800234015900
8054153426885863973
358068012002601760
40°
2010383673147993
129024543098.3635
0m 1m 2m 3m 4m 5m
15° - LuxFULL ONRGBW
231000437007660017400117000
578001090019100434029300
2574048508505193013000
15°
145002730479010907310
9250175030606954680
190mm540mm
340mm
IP54
www.prolight.co.uk Spectra Flood Q40 User Manual 4
01-Brackettighteningknobs
02-LCDdisplay
03-Functionbuttons
04-WirelessDMXantenna
05-PowerCONTRUE1input
06-PowerCONTRUE1output
07-IPrated5-PinXLRtrailinginput
08-IPrated5-PinXLRtrailingoutput
09-Fans
Inthebox:1 x fixture, 1 x power cable & 1 x user manual
Technical specifications
01 01
08
07
04 05 06 09 02 03
Underside mounting points:
www.prolight.co.uk Spectra Flood Q40 User Manual 5
Main Menu Sub Menu Options/Values Description
DMXControl
Address 001-512 DMXAddressSetting
Channels
4(4channelmode)
DMXChannelSetting6(6channelmode)
8(8channelmode)
W-DMXON
WirelessDMXSettingOFF
SlaveMode SlaveModeSetting
AutoMode AutoMode
Dimmer
Red 000-255
ManualDimmingModeGreen 000-255
Blue 000-255
White 000-255
Program Show
01C[--](Colour)-Seepage6forcolours
Built-inProgramsFlash[00-99]
02-14Speed[001-100]
Flash[00-99]
Settings
CurveSetting
Curves
Linear
DimmingCurvesSetting
SquareLaw
InvSquareLaw
S-Curve
DimmerSpeed
Fast
Smooth
Backlight-T
10S
BacklightTime
20S
30S
60S
ON
Backlight-L 01-10 BacklightBrightness
FactoryResetYES
FactoryResetNO
DMXFailOFF
DMXSignalFailureSettingHold
InformationTemperature FixtureTemperature
Software SoftwareVersion
Operating instructions
www.prolight.co.uk Spectra Flood Q40 User Manual 6
W-DMX settings:
ToenableW-DMX,pressthe“MENU”buttonandusethe“UP”and“DOWN”buttonstoselect“DMX Control”.Pressthe“UP”and“DOWN”buttonandusethe“UP”and“DOWN”buttonstoselect“W-DMX”.Nowusethe“UP”and“DOWN”buttonstoselect“ON”.
Pressthe“ENTER”buttontoconfirmthesetting.ThegreenLEDtotheleftofthedisplaywillflashindicatingitissearchingforasignal.
NowpairyourfixturewithyourW-DMXtransmitter.ThegreenLEDwillbecomestaticoncesucessfullypaired.
TodisableW-DMX,pressthe“MENU”buttonandusethe“UP”and“DOWN”buttonstoselect“DMX Control”.Pressthe“UP”and“DOWN”buttonandusethe“UP”and“DOWN”buttonstoselect“W-DMX”.Nowusethe“UP”and“DOWN” buttonstoselect“OFF”.Pressthe“ENTER”buttontoconfirmthesetting.
AlternativelywhenW-DMXisenabledpressandholdthe“MENU”button,thedisplaywillshow“W-DMX Lock Out”.OncethisiscompletetheW-DMXhasbeendisabled.
ThegreenLEDwillgoofftoconfirmW-DMXhasbeendisabled.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Operating instructions
4 channel mode:
Channel Value Function
1 000-255 Red(0-100%)
2 000-255 Green(0-100%)
3 000-255 Blue(0-100%)
4 000-255 White(0-100%)
6 channel mode:
Channel Value Function
1 000-255 Masterdimmer(0-100%)
2 000-255 Red(0-100%)
3 000-255 Green(0-100%)
4 000-255 Blue(0-100%)
5 000-255 White(0-100%)
6 000-255 Strobe(slow-fast)
0 Blackout
1 Red
2 FlameRed
3 DeepGoldenAmber
4 MillenniumGold
5 GoldAmber
6 Orange
7 ChromeOrange
8 DeepAmber
9 SpringYellow
10 LimeGreen
11 JASGreen
12 FernGreen
13 MossGreen
14 PrimaryGreen
15 DarkGreen
16 Green
17 MediumBlue/Green
18 LightBlue
19 LighterBlue
20 SteelBlue
21 HalfCTBlue
22 FullCTBlue
23 StateBlue
24 DoubleCTBlue
25 MediumBlue
26 JustBlue
27 DeepBlue
28 Blue
29 CongoBlue
30 SurprisePink
31 FuchsuiaPink
32 FolliesPink
33 SpecialRosePink
34 Pink
35 MoroccanPink
36 WarmWhite
37 ColdWhite
38 White
Colour macros:
www.prolight.co.uk Spectra Flood Q40 User Manual 7
Value CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8
000
Masterdimmer(0-255)
Red(0-255)
Green(0-255)
Blue(0-255)
White(0-255)
Nofuntion Nofuntion Nofunction
001-018 Program1
Value Colour
Strobe(0-255)
000-010 Blackout
011-016 Red
017-022 FlameRed
023-028 DeepGoldenAmber
029-034 MillenniumGold
035-040 GoldAmber
041-046 Orange
047-052 ChromeOrange
053-058 DeepAmber
059-064 SpringYellow
065-070 LimeGreen
071-076 JASGreen
077-082 FernGreen
083-088 MossGreen
089-094 PrimaryGreen
095-100 DarkGreen
101-106 Green
107-112 MediumBlue/Green
113-118 LightBlue
119-124 LighterBlue
125-130 SteelBlue
131-136 HalfCTBlue
137-142 FullCTBlue
143-148 StateBlue
149-154 DoubleCTBlue
155-160 MediumBlue
161-166 JustBlue
167-172 DeepBlue
173-178 Blue
179-184 CongoBlue
185-190 SurprisePink
191-196 FuchsuiaPink
197-202 FolliesPink
203-208 SpecialRosePink
209-214 Pink
215-220 MoroccanPink
221-226 WarmWhite
227-232 ColdWhite
233-255 White
7 channel mode:
Operating instructions
www.prolight.co.uk Spectra Flood Q40 User Manual 8
Operating instructions
7 channel mode cont.:
Value CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8
019-037
Masterdimmer(0-255)
Red(0-255)
Green(0-255)
Blue(0-255)
White(0-255)
Program2
Speed(slow-fast)Strobe(0-255)
038-056 Program3
057-075 Program4
076-094 Program5
095-113 Program6
114-132 Program7
133-151 Program8
152-170 Program9
171-189 Program10
190-208 Program11
209-227 Program12
228-246 Program13
247-255 Program14
www.prolight.co.uk Spectra Flood Q40 User Manual 9
DMX setup
FurtherDMXcablescanbepurchasedfromallgoodsoundandlightingsuppliersorProLightConceptsdealers.Pleasequote:
CABL10 – 2mCABL11 – 5mCABL12 – 10m
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachfixturerequiresa“startaddress”from1-512.Afixturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannelindicatedbythestartaddress.Forexample,afixturethatoccupiesoruses7channelsofDMXandwasaddressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthechainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligentfixturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothefixture.DMXdataissentasserialdatathattravelsfromfixturetofixtureviatheDATA“IN”andDATA“OUT”XLRterminalslocatedonallDMXfixtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogetherandoperatefromasinglecontroller,aslongasallfixturesandthecontrollerareDMXcompliant.ToensureproperDMXdatatransmission,whenusingseveralDMXfixturestrytousetheshortestcablepathpossible.TheorderinwhichfixturesareconnectedinaDMXlinedoesnotinfluencetheDMXaddressing.Forexample;afixtureassignedtoaDMXaddressof1maybeplacedanywhereinaDMXline,atthebeginning,attheend,oranywhereinthemiddle.WhenafixtureisassignedaDMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisfixturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,seeimagebelow.
Also remember that DMX cable must be daisy chained and cannot be split.
www.prolight.co.uk Spectra Flood Q40 User Manual 10
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.DonotconnectthecablesshieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRsoutercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,youmayneedtouseaterminatoronthelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRfixturesmaybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmissionproblemsandinterferance.itisalwaysadvisabletoconnectaDMXterminal,(resistance120Ohm1/4W)betweenpin2(DMX-)andpin3(DMX+)ofthelastfixture.
5-pin XLR (female)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C
3-pin XLR (female)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)
3-pin XLR (male)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)
5-pin XLR (male)Pin 1: GND (screen)Pin 2: Signal (-)Pin 3: Signal (+)Pin 4: N/CPin 5: N/C
DMX setup
www.prolight.co.uk Spectra Flood Q40 User Manual 11
WEEE notice
Correct Disposal of this Product (Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedofwithotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtotheenvironmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromothertypesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheirlocalgovernmentoffice,fordetailsofwhereandhowtheycantakethisitemforenvironmentallysaferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthepurchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.