Spec Sheet - CryoVation

2
Spec Sheet W50 Pump The CryoVation W50 is a liquid transfer pump fitted with operating controls. The unit is designed to receive liquid carbon dioxide (CO2) or nitrous oxide (N20) at an inlet pressure of about 300 PSIG (17.6 kg/cm2), and deliver it into portable cylinders at a regulated pressure ranging from about 400 PSIG (28.2 kg/cm2) to 900 PSIG (63.3 kg/cm2). For filling of conventional industrial cylinders a fill manifold and scale(s) are required. This equipment is sold separately. Contact CryoVation for various models available, ranging from manually operated to fully automated. Features ___________________________________________ • Pump – Single-stage, single-acting transfer pump with automatic safety bypass valve. The unit is intended for handling liquid carbon dioxide and nitrous oxide, when properly cleaned for “Oxygen Service” and lubricated with “Halocarbon” oil, for liquid nitrous oxide. • Drive - 7 1/2 horsepower, totally enclosed, fancooled motor drives the pump through a pulley and triple V- belt combination. The data plate on the motor will identify voltage requirements and special characteristics. • Automatic Bypass Valve - This valve serves to relieve the system pressure when discharge flow has been stopped or exceeds 1000 psi (70 kg/cm2). Bypass liquid is returned to the liquid supply vessel. • Pressure Gauge - This liquid-filled gauge indicates delivery pressure at the discharge of the pump. • Relief Valve - A relief valve is installed in the discharge line to protect the pump from possible over-pressurization. Technical Specifications: Fluid: LCO2 & LN2O Flow Rate: 50 Lb./Min (22 kg/Min.) Inlet PSI/Min: 290 PSIG (20.4 kg/cm2) Discharge PSI: 1,000 PSIG (70.4 kg/cm) Adjustable maximum Pump Speed: 452 RPM Motor: 7.5 HP, TEFC Pump Style: Reciprocating Voltage: 240/480 V, 3-phase, 60 Hz Bore: 1.625” Stroke: 1.75” Weight: - CryoVation | 609.914.4792 [email protected] | CryoVation.com | TheCryoShop.com

Transcript of Spec Sheet - CryoVation

Page 1: Spec Sheet - CryoVation

Spec Sheet

W50Pump

The CryoVation W50 isa liquid transferpumpfittedwithoperatingcontrols.Theunitisdesignedtoreceiveliquidcarbondioxide(CO2)ornitrousoxide (N20) at an inlet pressure of about 300PSIG(17.6kg/cm2),anddeliveritintoportablecylinders at a regulatedpressure ranging fromabout 400 PSIG (28.2 kg/cm2) to 900 PSIG(63.3 kg/cm2).

For filling of conventional industrial cylindersa fill manifold and scale(s) are required. Thisequipmentissoldseparately.ContactCryoVationfor various models available, ranging frommanuallyoperatedtofullyautomated.

Features ___________________________________________

• Pump–Single-stage,single-acting transferpumpwithautomaticsafetybypassvalve.Theunit isintended for handling liquid carbon dioxide and nitrous oxide, when properly cleaned for “OxygenService”andlubricatedwith“Halocarbon”oil,forliquidnitrousoxide.

• Drive -71/2horsepower,totallyenclosed,fancooledmotordrivesthepumpthroughapulleyandtripleV-beltcombination.Thedataplateonthemotorwillidentifyvoltagerequirementsandspecialcharacteristics.

• Automatic Bypass Valve-Thisvalveservestorelievethesystempressurewhendischargeflowhasbeenstoppedorexceeds1000psi(70kg/cm2).Bypassliquidisreturnedtotheliquidsupplyvessel.

• Pressure Gauge -Thisliquid-filledgaugeindicatesdeliverypressureatthedischargeofthepump.

• Relief Valve - A relief valve is installed in thedischarge line to protect the pump from possibleover-pressurization.

TechnicalSpecifications:

Fluid: LCO2 & LN2OFlow Rate: 50 Lb./Min (22 kg/Min.)Inlet PSI/Min: 290 PSIG (20.4 kg/cm2)Discharge PSI: 1,000PSIG(70.4kg/cm) AdjustablemaximumPump Speed: 452 RPMMotor: 7.5HP,TEFCPump Style: ReciprocatingVoltage: 240/480V,3-phase,60HzBore: 1.625”Stroke: 1.75”Weight: -

CryoVation | 609.914.4792 [email protected] | CryoVation.com | TheCryoShop.com

Page 2: Spec Sheet - CryoVation

W50Pump

Spec Sheet

CryoVation | 609.914.4792 [email protected] | CryoVation.com | TheCryoShop.com

W50Pump

Each pumpmanufactured by CryoVation ismechanically andcryogenicallytestedpriortoshipmenttoensurethatperformancemeets customer specifications. The precision of measuringdevicesprovidesessential results: differential head, flow rate,seal gas consumption, pump efficiency, NPSH, noise andvibrationlevels-alldocumentedandsubmittedtothecustomer.

___________Oil Type:CarbonDioxide SAE30motoroil,non-detergentNitrousOxide KrytoxOil,p/n6353-5270Oil Fill: Tocenterlineofsightglass