Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive...
-
Upload
eleanore-osborne -
Category
Documents
-
view
234 -
download
0
Transcript of Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive...
![Page 1: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/1.jpg)
Spatial and temporal limits of fMRISpatial and temporal limits of fMRI
• Menon RS, Kim SG. Spatial and temporal limits in cognitive
neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.
With supplementary material from:
• Menon RS, Goodyear BG. Submillimeter functional localization in human
striate cortex using BOLD contrast at 4 Tesla: implications for the vascular
point-spread function. Magn Reson Med. 1999 Feb;41(2):230-5.
• Menon RS, Luknowsky DC, Gati JS. Mental chronometry using latency-
resolved functional MRI. Proc Natl Acad Sci U S A. 1998 Sep 1;95(18):10902-7.
Presentation by Robert PinkertonPresentation by Robert Pinkerton
![Page 2: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/2.jpg)
ResolutionResolution
““The ability to resolve 2 different regions of neural The ability to resolve 2 different regions of neural activation.” activation.”
fMRI System ParametersfMRI System Parameters
TemporalTemporal- Volume Acquisition Time (VAT)- Volume Acquisition Time (VAT)
SpatialSpatial - Voxel size - Voxel size
![Page 3: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/3.jpg)
QuestionsQuestions
A)A) How fast?How fast?
B)B) How small?How small?
![Page 4: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/4.jpg)
What are we measuring?What are we measuring?
![Page 5: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/5.jpg)
![Page 6: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/6.jpg)
The signalThe signal
Will this transceive surface coil array…Will this transceive surface coil array…
……??
i) 2 sii) 13 s
![Page 7: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/7.jpg)
LimitationsLimitations
- TechnologyTechnology- Signal to Noise Ratio (SNR)Signal to Noise Ratio (SNR)
- Physiology Physiology - The ultimate limiting factor!The ultimate limiting factor!
![Page 8: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/8.jpg)
Limitations: NoiseLimitations: Noise
- Signal to Noise Ratio (SNR)Signal to Noise Ratio (SNR)Noise Sources:Noise Sources:
PhysiologicalPhysiologicalrespiration, cardiac, motionrespiration, cardiac, motion
ExtrinsicExtrinsicSystem (RF Coil, Gradients, preamps System (RF Coil, Gradients, preamps
etc.)etc.)IntrinsicIntrinsic
Patient LoadingPatient Loading
![Page 9: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/9.jpg)
Ultimately…Ultimately…
“ “Ultimately, it is the extent of the lateral Ultimately, it is the extent of the lateral connections and their inherent activity that connections and their inherent activity that will determine the cortical vasculature point will determine the cortical vasculature point spread function [spatial resolution] in spread function [spatial resolution] in different areas of the brain.”different areas of the brain.”
![Page 10: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/10.jpg)
Mapping ODC using the initial hyperoxygenated BOLD response
![Page 11: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/11.jpg)
![Page 12: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/12.jpg)
![Page 13: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/13.jpg)
Methods to increase spatial Methods to increase spatial resolution by using information resolution by using information
in the time domain.in the time domain.
![Page 14: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/14.jpg)
DipTR ~ 500 ms
![Page 15: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/15.jpg)
Mental Rotation: Figure 1, Menon & Kim
![Page 16: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/16.jpg)
Mental Rotation: Figure 1, Menon & Kim
![Page 17: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/17.jpg)
Widthcompare width to RT
![Page 18: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/18.jpg)
Mental Mental ChronometryChronometry
Menon et al, Proc. Natl. Acad. Sci. USA 1998
![Page 19: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/19.jpg)
Answers: It all depends!Answers: It all depends!
A)A) How fast?How fast?VAT ~ 50 ms - 3 sVAT ~ 50 ms - 3 s
Resolution:
~ 2s normal for ROI studies~ 500 ms for DIP measurements~ 100 ms for single event trials~ 50 ms for one slice, poor res
![Page 20: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/20.jpg)
Answers: It all depends!Answers: It all depends!
B)B) How small?How small?
x, x, y ~ 0.1 - 3 mmy ~ 0.1 - 3 mm
Resolution:
~ 3.8 mm diameter of PSF for feline cortex due to 1mm2 patch of activation~ 0.6 mm diameter of PSF for human cortex odc~ 0.1 mm capillary separation
![Page 21: Spatial and temporal limits of fMRI Menon RS, Kim SG. Spatial and temporal limits in cognitive neuroimaging with fMRI. Trends Cogn Sci. 1999 Jun;3(6):207-216.](https://reader035.fdocuments.in/reader035/viewer/2022081503/5697c00f1a28abf838cca471/html5/thumbnails/21.jpg)