Space Frame Structures for SNAP
description
Transcript of Space Frame Structures for SNAP
![Page 1: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/1.jpg)
Space Frame Structures for SNAPSpace Frame Structures for SNAP
Bruce C. Bigelow
University of Michigan
Department of Physics
11/04/04
![Page 2: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/2.jpg)
2
Space Frames for SNAPSpace Frames for SNAP
SNAP already has baseline primary and secondary structures. Why look at others?
Minimizing structure mass = mission flexibility Higher resonant frequencies are (almost) always better Minimizing carbon fiber mass reduces H2O dry-out issues
Open structures provide maximum access to payloads Space frame structures are prevalent in space (heritage)
![Page 3: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/3.jpg)
3
Space FramesSpace Frames
Features: Loads carried axially (ideally) Joints/nodes carry some moments (not space truss) Deflections scale linearly with length:
d = PL/AE loads carried in tension/comp. (SF) Versus:
d = PL/nAG loads carried in shear (monocoque) d = PL^3/nEI loads carried in bending
Fast and easy to model with FEA Facilitate test and integration Space frames are ideal for supporting discrete loads Space frames make poor fuel tanks and fuselages…
![Page 4: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/4.jpg)
4
Space Frames for SNAPSpace Frames for SNAP
Status of space frames for SNAP(PPT presentations in BSCW PS1300/Weekly):
Space frame spectrograph mount 05/14/04 Athermal (constant length) strut designs 06/04/04 Det. space frame designs for TMA-63 07/29/04 Indet. Space frame designs for TMA-65 08/26/04 Node/joint design concepts 09/02/04 Survey of space heritage structures 09/02/04 Minimum obscuration SMA structure 09/16/04 TMA 65, fold mirror, and lower baffle 10/28/04
![Page 5: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/5.jpg)
5
Spectrograph mountSpectrograph mount
Design features: Hexapod space frame to carry 10Kg spectrograph 2:1 hexapod geometry => horizontal deflections, no tilts Attaches to common focal plane mounting points
Essentially no loads carried by focal plane assembly Simple interface to spectrograph
3 discrete support points, or round flange Supports spectrograph load near center of mass
Minimizes moment loads Simple interface to FP (mount points, cylindrical volumes) Spectrograph and mount easily separate from FPA Invar, CF, or athermal struts
Simple control of spectrograph thermal defocus
![Page 6: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/6.jpg)
6
FEA ModelFEA Model
SNAP Baseline design:
• Moly, Invar, Ti flexures
• Attaches to FPA baseplate
• Loads carried near detect.
Natural frequencies for spectrograph, mount, and flexures: 116, 121, 164 Hz.
Mass: ?
![Page 7: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/7.jpg)
7
Spectrograph mounting structureSpectrograph mounting structure
Ease of access to detector connectionsFP assembly with spectrograph included (note redundant str.)
![Page 8: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/8.jpg)
8
Dynamic FEADynamic FEA
f1 = 413 Hz, transverse mode, 25 x 2 mm Invar struts, 2.5 Kg, f1 = 675 Hz for carbon fiber (MJ55), 25 x 2 mm struts, 0.5Kg
First 6 freq:
1. 413 Hz
2. 415 Hz
3. 416 Hz
4. 470 Hz
5. 478 Hz
6. 490 Hz
![Page 9: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/9.jpg)
9
Athermal StrutsAthermal Struts
Design features: Thermally compensated or controlled length struts 3 materials to provide varying expansion/contraction Avoid high stresses due to CTE mismatches Provide integral flexures for kinematic constraints Provide features for length adjustments (alignment) Application details required for FEA
![Page 10: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/10.jpg)
10
Athermal StrutsAthermal Struts
Blue = Ti CP Grade 1 --- 17 PPM/K
Light Grey = Invar --- 1.26 PPM/K
Dark Grey = Ti 6Al 4V --- 6.7 PPM/K
L1 = 156mm, L2 = 78mm, L3 =222mm(x2), 600mm long strut
![Page 11: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/11.jpg)
11
Athermal StrutsAthermal Struts
EDM cross-flexure2:1 truss geometry on focal plane assy, 600mm long struts
![Page 12: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/12.jpg)
12
OTA Space FramesOTA Space Frames
Motivations: Minimize telescope structure deflections under gravity Maximize resonant frequencies on ground and in orbit Minimize structure mass, CF outgassing, etc. Maximum access to optical elements (assembly, test) Explore parameter space for SNAP structure
![Page 13: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/13.jpg)
13
OTA Space Frames – TMA 63OTA Space Frames – TMA 63
Design objectives: Maintain symmetry to extent possible Locate nodes for access to primary loads
3 nodes above secondary mirror for hexapod mount 3 nodes above primary for secondary support 3 nodes behind primary for mirror, attach to SC 3 nodes below tertiary axis to stabilize secondary supp.
Locate nodes and struts to avoid optical path Size struts to minimize mass and deflections Round struts used for constant stiffness vs. orientation Non-tapered struts used – easy for first cut designs COI M55J carbon fiber composite used for all struts CF can be optimized for cross section, thermal expansion
![Page 14: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/14.jpg)
14
OTA Space Frames – TMA 63OTA Space Frames – TMA 63
![Page 15: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/15.jpg)
15
TMA-63 structure FEATMA-63 structure FEA
Elements
![Page 16: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/16.jpg)
16
Dynamic FEADynamic FEA
Dynamic analyses: Telescope mass: 360kg payload, 96kg structures Modal analysis for ground, launch
f1 = 72 Hz f2 = 74 Hz f3 = 107 Hz f4 = 114 Hz f5 = 131 Hz
Modal analysis for on-orbit (unconstrained) f7 = 106 Hz f8 = 107 Hz
![Page 17: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/17.jpg)
17
Static FEAStatic FEA
First ground mode, 72 Hz
![Page 18: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/18.jpg)
18
Nodes for space framesNodes for space frames
Design features: Nodes connect the struts in a space frame Accommodate diameters of struts (constant diameter, wall) Minimize mass (often a large fraction of the mass in a SF) Maximize ease of fabrication and assembly Provide attachment points for secondary structures
![Page 19: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/19.jpg)
19
Nodes for space framesNodes for space frames
• Molded node, 22mm x 2mm tubes, V = 13103 mm^3
• Invar = 0.1 Kg, Ti = 0.06 Kg, CC = 0.02 Kg
![Page 20: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/20.jpg)
20
Nodes for space framesNodes for space frames
• Machined node, 22mm OD tubes, V = 58561 mm^3
• Invar = .47 Kg, Ti = 0.26 Kg, CC = 0.09 Kg
![Page 21: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/21.jpg)
21
Secondary Mirror StructureSecondary Mirror Structure
Design features: Minimize pupil obscuration by SMA structures Minimize structure mass Maintain high first resonance Secondary support vanes:
25 mm diameter x 2 mm wall Requires revisions to current outer baffle design
![Page 22: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/22.jpg)
22
Secondary StructureSecondary Structure
Blue/green hexapod struts are outside of CA
![Page 23: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/23.jpg)
23
Secondary StructureSecondary Structure
Trial 9, ring at 2.85m elev.
![Page 24: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/24.jpg)
24
Space frame developmentsSpace frame developments
Latest work: TMA 65 structure with nodes Fold mirror sub-frame Lower baffle structure (Al) and close-outs
Rings have 50 x 50 x 3 mm sections Struts have 50 x 50 x 6mm sections Upper baffle mass = 190 Kg Baffle structure (38 Kg) + close-outs (27 Kg) = 65 Kg f1 = 33 Hz CF baffle structure: 20Kg, 40Hz
![Page 25: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/25.jpg)
25
TMA-65 structure with nodesTMA-65 structure with nodes
![Page 26: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/26.jpg)
26
Fold mirror sub-structureFold mirror sub-structure
![Page 27: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/27.jpg)
27
Lower baffle structureLower baffle structure
![Page 28: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/28.jpg)
28
Lower baffle, structure clearanceLower baffle, structure clearance
![Page 29: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/29.jpg)
29
Deformation in 1g held by GSEDeformation in 1g held by GSE(baffle displacement~2.6mm)(baffle displacement~2.6mm)
Baseline: mass = 79 Kg
![Page 30: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/30.jpg)
30
Lower baffle structureLower baffle structure
mass = 65 Kg
![Page 31: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/31.jpg)
31
Baffle/OTA Assembly Mode 1, 20HzBaffle/OTA Assembly Mode 1, 20Hz
![Page 32: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/32.jpg)
32
Lower baffle structureLower baffle structure
![Page 33: Space Frame Structures for SNAP](https://reader035.fdocuments.in/reader035/viewer/2022062314/568139bc550346895da15fba/html5/thumbnails/33.jpg)
33
Space frames for SNAPSpace frames for SNAP
Conclusions: Space frames are applicable to most SNAP structures Space frame structures offer significant mass reductions over
current baseline designs Space frame structures provide higher frequencies/mass
compared to baseline designs Space craft structure heritage is well established Space frame structures will readily scale to larger apertures Space frames for SNAP: Ready for prime time!