SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance...

71
SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual V0.3 Beijing StarPoint Technology Company Ltd.

Transcript of SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance...

Page 1: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management

Conformance Test System User Manual

V0.3

BBeeiijjiinngg SSttaarrPPooiinntt TTeecchhnnoollooggyy CCoommppaannyy LLttdd..

Page 2: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual.

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual. I

Copyright

Beijing StarPoint Tecnology Company Ltd. © 2012 Copyright, all rights reserved.

Without the written intimation from Beijing StarPoint Tecnology Company Ltd., any

organization or individual shall not modify or extract any part of this manual in any way.

Page 3: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual.

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual. II

Page 4: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual.

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual. III

Modify records

The modifier Date Amendant Record Release

ZhangAiQin 5.28 Completed the first draft V0.1

ZhangAiQin 6.12

Modifying the hardware architecture, add the SP8200 and

SP6200 Integrated System V0.2

ZhangMingYang 9.27 To join UE automated testing, software installation V0.3

Page 5: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual.

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual. IV

Contents

COPYRIGHT ....................................................................................................................................... I

CONTENTS ....................................................................................................................................... IV

1. PREFACE .................................................................................................................................... 1

1.1. OVERVIEW ............................................................................................................................. 1

1.2. CONTENTS OF THE GUIDE ...................................................................................................... 1

1.3. GLOSSARY ............................................................................................................................. 2

1.4. SECURITY INFORMATION DESCRIPTION ................................................................................. 2

1.4.1. Working Environment ................................................................................................ 2

1.4.2. Notes ........................................................................................................................... 3

1.4.3. Product Certification .................................................................................................. 3

2. SP8200 SYSTEM ......................................................................................................................... 4

2.1. SYSTEM OVERVIEW ............................................................................................................... 4

2.2. SYSTEM HARDWARE .............................................................................................................. 6

2.2.1. Composition of Hardware ......................................................................................... 6

2.2.2. Hardware Connection ..............................................................................................15

2.3. SYSTEM SOFTWARE ..............................................................................................................19

2.3.1. Composition of Software ..........................................................................................19

3. SP8300 SOFTWARE INSTRUCTIONS ..................................................................................20

3.1. TS MANAGER .......................................................................................................................20

3.1.1. Introduction ................................................................................................................20

3.1.2. Instructions .................................................................................................................26

3.2. EDIT PARA ............................................................................................................................32

3.2.1. Introduction ................................................................................................................32

3.2.2. Instructions .................................................................................................................34

3.3. LOG TRACER ........................................................................................................................35

3.3.1. Introduction ................................................................................................................35

3.3.2. Instructions .................................................................................................................42

3.4. DRIVER ................................................................................................... 错误!未定义书签。

4. SP8300 TEST PROCEDURE ....................................................................................................54

5. SP8200 AND SP6200 INTEGRATED SYSTEM .....................................................................55

5.1. SYSTEM INTRODUCTION .......................................................................................................55

5.1.1. System Overview ......................................................................................................55

5.2. FUNCTION INTRODUCTION ....................................................................................................56

5.2.1. TEST PLAN MANAGEMENT ...............................................................................................57

5.2.2. TEST CASE RUNNNING WINDOW ......................................................................................59

5.2.3. PARAMETER CONFIGURE ..................................................................................................59

Page 6: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual.

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual. V

5.2.4. VIEW LOG INFORMATION .................................................................................................60

6. MATTERS NEED ATTENTION ..............................................................................................64

6.1. OPERATION PROHIBITED .......................................................................................................64

6.2. GENERAL SUGGESTIONS .......................................................................................................64

7. MAINTENANCE AND TECHNIQUE SUPPORT .................................................................65

Page 7: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

1

1. Preface

1.1. Overview

SP8200 system supply all tests of UE on LTE single mode and LTE/TD-SCDMA/GSM multi

mode which defined in 3GPP 36.521-3. It mainly include mobile performance test under

E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status,

RRC connected mobile control ability test, test of ability of clock synchronization and ability of

signal monitoring, measurement procedure relevant test, measurement performance relevant test

and so on.

Its major functions are as follows:

Cover the test cases defined in specification overall.

Support configuration of LTE single cell, LTE Intra-Freq/Inter-Freq multiple cells,

LTE/TD-SCDMA/GSM Inter-RAT multiple cells, and support LTE-FDD/WCDMA in

future.

Professional test

The execution process, measurement algorithm, jugement algorithm, and antenna connction

type, channel environment configurement of each test case is conformity with specification.

The test system and test case will conformed by GCF.

Support UE automatic control

Used the standard AT conmand interface or special interface supply by factory, the UE is

controlled by test system to switch on/off automatically, which can reduce the amount of

work of oprator. At the same time it leads to testing day and night continunously, which

shorten the period of UE authentication.

Supply perfect Log tool.

Include the interface of diaplaying test process and test point in real time, and detailed log

file. It can help user fix the problem of UE.

Support diversity test scheme user defined to meet using in special environment.

User can modify fault-tolerance and judement scheme of predefined test case. Antenna

connection type and channel environment can be configured flexibility.

Suppport user defined test case.

Guided by development manual, user can establish different procedure, signaling parameter

and test case by invoking basic process function, and special control function, special

algorithm, which meet user’s special test/debug requriment.

1.2. Contents of the Guide

The user manual contains comprehensive usage information, and the specific content will be

Page 8: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

2

described in details in later chapters. See the detailed title and content of the profile as Table 1-1:

Table 1-1 User Manual Content

Chapter Number and Name Content Overview

Chapter 1 Preface Contents of the Software, contents of the Guide, glossary and

matters needing attention in ahead of application.

Chapter 2 SP8200 System Composition of SP8200 System, including composition of

hardware, hardware interface and composition of software.

Chapter 3 SP8200 Software

Instructions Instructions of various softwares needed by SP8200.

Chapter 4 SP8200 Test

Procedure SP8300 Test Operation Procedure.

Chapter 5 SP8200 and SP6200

integrated system Introduce the SP8200 and SP6200 integrated system

Chapter 6 Matters Need

Attention

Introduce notes of SP8200,such as Operation Prohibited,

General Suggestions, Blank Screen Handling and so on.

Chapter 7 Maintenance and

Technique Support Maintenance and Technical Support.

1.3. Glossary

Table 1-2 Glossary

Abbreviation English full name

TD-LTE Time Division – Long Term Evolution

SP8200 SP8200 TD-LTE Terminal RRM Conformance Test Set

SS System Simulator

RFSC RF Switch Controller

CE Channel Emulator

TC Test Case

TTCN-3 Testing and Test Control Notation version 3

API Application Program Interface

1.4. Security Information Description

1.4.1. Working Environment

Environment Requirements

SP8200 LTE Terminal Radio Resource Management Conformance Test System(hereinafter

referred to as SP8200)is for Class II equipment installation, and it is properly to run indoor

Page 9: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

3

environment as 2nd level pollution degree. The working temperature is +5 ℃ to + 45 ℃, the

maximum working relative humidity is 80%, and the maximum working altitude is 2000m.

Ventilation Requirements

If the instruments are installed in the cabinet, the cabinet should ventilate freely. If the total

power dissipation inside of the cabinet is above 800W, the forced ventilation is required.

Voltage requirements

110-230V~5.0A,47-63Hz.

1.4.2. Notes

Three preventions

Include water-proof, anti-static, and anti-electromagnetic interference.

Fuses

Fuse can only be uses as rating current and voltage and indicated common type and delay type.

Please do not use repaired fuses or short-circuit fuse seat to prevent from electric shock and fire.

Voltage Matching

Ensure that the instrument setting is matching with line voltage before power on, and install the

proper fuse with security measures. Please refer to the Safety Symbols which is about the

symbols outside of the instrument.

Instrument Grounding

To minimize the risk of electric shock, the rack and housing of instrument must be connected

with electrical grounding protection terminals. The instrument must be connected with AC power

through an earthling cable which must be firmly connected with electrical connecting side

(safety grounding) of power plug. It might result in potential risk of electrical shocking if

interrupted any earthling protection conductor or disconnected any grounding protection

terminals.

No disassemble to the instrument shell

The operator can not disassemble the instrument shell. Any parts of internal instrument can be

only replaced and adjusted by the professional maintenance staff. Once have any damages or

dysfunctional signs, stop operation immediately and wait for professional maintenance staff to

repair.

No operation in explosive environment

Do not use the instrument in the environment of existing flammable gases or fog.

1.4.3. Product Certification

1. Beijing Starpoint Telecommunication Software Co., Ltd has certified by ISO 9001. The

certification number is 01609Q22045R1M;

Page 10: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

4

2. SP8200 System

2.1. System Overview

SP8200 LTE Terminal Radio Resource Management Conformance Test System (SP8200) is set

up on the base of LTE hardware and software platform, and TD-SCDMA hardware and software,

which are developed by Beijing StarPoint Technology Company Ltd..

SP8200 could compelet the RRM conformance test in LTE single mode and

LTE/TD-SCDMA/GSM multi mode, it also outputs test result and generates log in detail.

SP8200 is composed by following software and hardware, shown as Table 2-1.

Table 2-2 Hardware Composition of SP8200 System

Hardware

System Managing Computer

LTE SS(SP8300)

Main Controller module

Base band processing unit

Radio Frequency module

TD-SCDMA SS(SP6300T)

GSM SS(SP8300G)

RF Switch Controller and RF Switch Controller Filter

Channel Emulator(CE)

Router

KVM Switch

Displayer, Keyboard and Mouse

Software

System manage

computer software

Test Case software

Test Suit managing software

Log Tracer

LTE system simulator software

TD-SCDMA system simulator software

LTE RRM RF Switch Controller software

GSM system simulator software

Accessory

cable

RF cable

10MHz clock signal cable

Trigger cable

NetWork cable

SP8200 syetem’s facade is shown as Figure 2-1.

Page 11: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

5

37 U

1 U

1 U

1 U

1 U

M4400-M

SP8300

SP8300

1 U

2 U 2 U

Channel

Emulator

1 U

SP6300T

SP8300G

37 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

2 U

M4400-S

1 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

1 U

Figure 2- 1 SP8200’s facade

SP8200’s configuration is shown as Table 2-2:

Table 2-2 SP8200’s configuration

Hardware

System managing computer 1

TD-LTE SS(SP8300) 2

TD-SCDMA SS(SP6300T) 1

GSM SS (SP8300G) 1

RF Switch Controller 1

Channel Emulator 1

Router 1

KVM switch controller 1

Diaplayer, Keyboard,Mouse 1

Software

SP8200 TD-LTE test case software 1

SP8200 test suit managing software 1

Log Tracer 1

TD-LTE system simulator software 2

TD-SCDMA system simulator

software 1

GSM system simulator software 1

TD-LTE RRM RF Switch controller 1

Page 12: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

6

software

Cable

RF cable Several

10MHz clock signal cable Several

Trigger cable Several

Network cable Several

2.2. System Hardware

2.2.1. Composition of Hardware

2.2.1.1. System Managing Computer

System Managing Computer is the control center of the whole system, it is used to control the

running of software and hardware on each device, to compele system selftest, and to implement

TTCN-3 runnable test suit.

System Managing Computer also is the UI concentrate location of the whole system, including

test managing UI, Log analyzing UI, and test case developing UI which TTCN-3 user defined.

Moreover, System Managing Computer control UE via AT port.

The ports System Managing Computer supply is described as Table 2-2 shown.

Table 2-2 Exterior Interface of System Managing Computer

Name of Interface Functional Description Amount

LAN Standerd 10/100M network port 1

VGA Standerd VGA video port 1

USB Standerd USB 2.0 port 2

The ports descrided above on System Managing Computer are shown in Figure 2-2.

VGALAN

System Manage Computer Back Panel

System Manage Computer Front Panel

USB

USB

Figure 2- 2 Schematic diagram of interfaces’ distribution on System Managing Computer

Page 13: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

7

2.2.1.2. LTE SS

LTE SS means LTE system simulator. It could simulate a normal or abnormal LTE cell in same

time interval, and also could simulate diffrent LTE cells in different time interval.

LTE SS is consist of SP8300 Protocol Analyzer(SP8300),system standerd configure two

SP8300s, Which can be extended more according test requirement.

The interface of LTE SS is described in Table2-3:

Table 2-3 Exterior Interface of SP8300

Type of Interface Name of Interface Functional Description Amount

RF Interface

RF OUT Interface for output of RF signal 2

RF IN/OUT Bidirectional interface for input

and output of RF signal

2

Base band

Interface

CASCADE in/out1 Bidirectional interface for input

and output of HDMI signal (not

use)

2

TRIGGER IN Sync signal input interface with

a cycle of 5ms frame.

1

TRIGGER OUT Sync signal output interface

with a cycle of 5ms frame.

1

10MHz IN/OUT Bidirectional interface for

10MHz reference clock

1

Control Interface

LAN Interface for transferring data

and control message between

SP8300 and System Managing

Computer

1

GPIB Standard GPIB interface. 1

Other Interface

POWER Power on 2

RESET Reset 1

AUDIO IN Interface for input Audio signal 1

AUDIO OUT Interface for output Audio signal 1

AUX Auxiliary interface 1

VGA Displayer interface 1

USB Standard USB 2.0 interface 3

The Interface described above on SP8300 is shown in Figure 2-3.

Page 14: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

8

SP8300 Front Panel

POWER RESET USB USB

RF1

OUT IN/OUT OUT IN/OUT

RF2

SP8300 Back PanelTRIGGER

INTRIGGER OUT

AUDIOIN

AUDIOOUT AUX 10MHz

CASCADE in/out1

CASCADE in/out2

USB VGA LAN GPIB POWER

Figure 2- 3 Schematic diagram of interfaces’ distribution on SP8300

2.2.1.3. SP6300T

SP6300T means TD-SCDMA system simulator, which is used to simulate controlled

TD-SCDMA cell. Its main functions include complete function of protocol stack L1 and L2 on

UTRAN; special function of L1 and L2 to meet test requirement; under controlled condition to

complete system brocast message, random access, register, paging, measurement control, control

of reselection and switch between different systems; and other process of UTRAN.

SP6300T supports TD-SCDMA enhance technology, and can simulate multi TD-SCDMA cells at

the same time.

SP6300T use SP6300 TD-SCDMA Protocol Analyze Tester, The interface of SP6300T is

described in Table2-4:

Table2-4 Exterior Interface of SP6300T

Type of Interface Name of Interface Functional Description Amount

RF Interface IN/OUT Bidirectional interface for input

and output of RF signal

2

OUT Interface for output of RF signal 2

Base band Interface

CASCADE

IN/OUT

Bidirectional interface for input

and output of HDMI signal (not

use)

2

TRIGGER IN Sync signal input interface with

a cycle of 5ms frame.

1

TRIGGER OUT Sync signal output interface

with a cycle of 5ms frame.

1

10MHz IN/OUT Bidirectional interface for 1

Page 15: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

9

10MHz reference clock

Control Interface

LAN Interface for transferring data

and control message between

SP6300T and System Managing

Computer

1

GPIB Standard GPIB interface 1

Other Interface

POWER Power on 1

AUDIO IN Interface for input Audio signal 1

AUDIO OUT Interface for output Audio signal 1

AUX Auxiliary interface 1

VGA Displayer interface 1

USB Standard USB 2.0 interface 3

The Interface described above on SP6300T is shown in Figure 2-4.

SP6300协议分析测试仪 后面板

SP6300T Back Panel

Power Reset

SP6300T Front Panel

USB 1 USB 2 OUT-RF1-IN/OUTOUT-RF2-IN/OUT

Figure 2- 4 Schematic diagram of interfaces’ distribution on SP6300T

2.2.1.4. SP8300G

SP8300G is used to simulate GSM cell, the interface of SP8300G is described in Table2-5:

Table2-5 Exterior Interface of SP8300G

Type of

Interface Name of Interface Functional Description Amount

Page 16: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

10

RF

Interface

RF IN/OUT Bidirectional interface for input and

output of RF signal

2

RF OUT Interface for output RF signal 2

CASCADE IN/OUT Bidirectional interface for input and

output of HDMI signal (not use)

2

TRIGGER IN Sync signal input interface with a

cycle of 5ms frame.

1

TRIGGER IN/OUT Bidirectional interface for input and

output Sync signal with a cycle of

5ms frame.

1

10MHz IN/OUT Bidirectional interface for 10MHz

reference clock

1

10MHz OUT Interface for output 10MHz reference

clock

1

AUDIO IN Interface for input Audio signal 1

AUDIO OUT Interface for output Audio signal 1

Control

Interface

LAN Interface for transferring data and

control message between SP8300G

and System Managing Computer

1

GPIB Standard GPIB interface 1

Other

Interface

Power Power on 1

Preset Preset system 1

AUX Auxiliary interface 1

VGA Displayer interface 1

USB Standard USB 2.0 interface 3

The Interface described above on SP8300G is shown in Figure 2-5.

SP8300G Back Panel

VGAUSB

TRIGGER INTRIGGER IN/OUT AUDIO OUT 10MHz OUT

LAN GPIB

AUDIO IN AUX 10MHz IN

CASCADE IN/OUT1 CASCADE IN/OUT2

PowerOUT-RF2-IN/OUT

SP8300G Front Panel

Preset OUT-RF1-IN/OUT

Figure 2-5 Schematic diagram of interfaces’ distribution on SP8300G

Page 17: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

11

2.2.1.5. CE

CE is Channel Emulator, which is used to emulate channel environment according to the

requirement of test case. It mainly simulates the environment of AWGN, multipath fading,

Doppler shift. CE can supply configuration of predefined typical channel modul, which include

the channel envioroment that most of test cases specified.

The equipment of CE is EB Propsim F8,Which interface is described in Table2-6.

Table 2-6 Exterior Interface of CE

Type of

Interface Name of Interface Functional Description Amount

RF Interface

IN(RF1~RF8) Interface for input RF signal 8

OUT(RF1~RF8) Interface for output RF signal 8

RFLO IN Interface for input LO signal 1

RFLO OUT Interface for output LO signal 1

Clock, Sync

signal

Interface

C1 Sync signal input interface 1

C2 Sync signal output interface 1

C3、C4 Bidirectional interface for input and

output Programable signal

2

10MHz REF IN Interface for input 10MHz

reference clock

1

10MHz REF OUT Interface for output 10MHz

reference clock

1

200MHz SCLK IN Interface for input 200MHz Sample

Clock signal

1

200MHz SCLK OUT Interface for output 200MHz

Sample Clock signal

1

IO CLK IN Interface for input 0-200MHz

Sample Clock signal

1

IO CLK OUT Interface for output 0-200MHz

Sample Clock signal

1

Control

Interface

LAN Interface for transferring data and

control message between CE and

Other systems (10/100/1000M

Interface)

1

GPIB Standard GPIB interface 1

IEEE 488 Bidirectional interface of 16-pin for

input and output Programable

signal

1

Other

Interface

POWER Power on 1

SWITCH Switch 1

DVI Interface for output DVI-A video 1

Page 18: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

12

signal

USB Standard USB 2.0 interface 4

The Interface described above on CE is shown in Figure 2-6.

EB

Propsim

F8

Front Panel

USB

IN OUT

LAN

GPIO DVI

C1 C2 C3 C4

10MHz REF IN10MHz

REF OUT

200MHz SCLK OUT

200MHz SCLK IN

IO CLK IN

IO CLK OUT

RFLO IN RFLO OUT

IEEE 488

POWER

SWITCH

RF1

RF2

RF3

RF4

RF5

RF6

RF7

RF8

EB

Propsim

F8

Back Panel

Figure 2-6 Schematic diagram of interfaces’ distribution on EB Propsim F8

2.2.1.6. RFSC

RF Switch Controller complete input or output RF signal, and connection of UE antenner

automatically, which on base of specical RF connection of each test case and channel

environment set.

RF Switch Controller realize the connection which inconclude Figure A.9,Figure A.10,Figure

A.14,Figure A.15,Figure A.18,Figure A.19,Figure A.20 in Protocol 36.508 Annex A

RF Switch Controller is composed of Switch Controller M4400 and Switch Controller M4400

FILTERS.

The interface of Switch Controller M4400(M4400-M)is disribed in Table 2-7.

Table 2-7 Exterior Interface of Switch Controller M4400(M4400-M)

Type of

Interface Name of Interface Functional Description Amount

RF Interface

of LTE

SS1-TX1 1

SS1-TX2 Interface for input RF signal, which

is connected with RF OUT2

interface of LTE SS 01

1

SS1-RX1 Interface for output RF signal which

is connected with RF IN/OUT1

interface of LTE SS 01

1

Page 19: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

13

SS1-RX2 Interface for output RF signal which

is connected with RF IN/OUT2

interface of LTE SS 01

1

SS2-TX Interface for input RF signal, which

is connected with RF OUT1

interface of LTE SS 02

1

SS2-RX Interface for output RF signal which

is connected with RF IN/OUT2

interface of LTE SS 02

1

SS3-TX Interface for input RF signal, which

is connected with RF OUT1

interface of LTE SS 03

1

SS3-RX Interface for output RF signal which

is connected with RF IN/OUT2

interface of LTE SS 03

1

Other RF

Interface

TD-SCDMA-TX/RX Bidirectional interface for input or

output RF signal, which is

connected to RF TX/RX interface

of TD-SCDMA SS

1

GSM-TX Bidirectional interface for input or

output RF signal, which is connected

to RF TX interface of GSMSS

1

GSM-RX Bidirectional interface for input or

output RF signal, which is connected

to RF RX interface of GSM SS

RF Interface

of CE

CE-IN Interface for input RF signal,which

is used to receive one of two path

LTE RF signal processed by CE

4

CE-OUT Interface for output RF signal,which

is used to support one of two path

LTE RF signal to CE

2

RF Interface

of UE

RF-UE-RX Interface for input RF signal, which

is used to support receiving signal to

UE.

2

RF-UE-TRX Bidrectional interface for input or

output RF signal

2

Control

Interface

LAN Interface for transferring data and

control message between Switch

Controller M4400 and System

Managing Computer (100/1000M)

1

Other

Interface

POWER Power on 2

Switch Controller M4400(M4400-M)上的接口分布如图 2-7 所示:

Page 20: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

14

Switch Controller M4400

Switch Controller M4400 前面板

UE_RX UE_RX/TX

RF_UE_TRX

SS3_TX

CONTROL PORT

RF_TX

GSM_RX GSM_TX TD_RX TD_TX

RRM_UE_TRX SS1_TX1

CE_IN1 CE_IN2 CE_IN3 CE_IN4

RRM_UE_RX

SS2_RX

SS1_RX2 SS1_TX2

RF_UE_RX

SS3_RX

SS1_RX1

SS2_TX

LAN

POWERRF_RX

Switch Controller M4400 后面板

Figure 2-7 Schematic diagram of discibed interface on Switch Controller M4400

The interface of Switch Controller M4400 FILTERS(M4400-S)is disribed in Table 2-8:

Table 2-8 Exterior Interface of Switch Controller M4400 FILTERS

Type of

Interface

Name of

Interface Functional Description Amount

RF

Interface

of UE

RRM_UE_RX Interface for input RF signal, which is

connected to RF interface of UE

1

RRM_UE_TRX Bidrectional interface for input or output RF

signal,which is connected to RF interface of

UE

1

RF

Interface

of CE

CE-RF Interface for input RF signal,which is used to

receive one of two path LTE RF signal

processed by CE

4

Interface of Switch Controller M4400 FILTERS(M4400-S)is diacribed in Table 2-8:

RF Switch Controller

RRM_UE_TRXRRM_UE_RX

Switch Controller M4400 FILTERS Front Panel

CE_RF1 CE_RF2 CE_RF3 CE_RF4

CONTROL PORT

Switch Controller M4400 FILTERS Back Panel

Page 21: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

15

Figure 2-8 Schematic diagram of interface discribtion on Switch Controller M4400 FILTERS

2.2.1.7. KVM Switch

KVM Switch is used to switch the VGA, Keyboard and Mouse which is on LTE SS,

TD-SCDMA SS, GSM SS, RF Switch Controller, CE and System Managing Computer, so that it

can control all the equipments above.

Interface of KVM Switch is described in Table 2-9:

Table 2-9 Exterior interface of KVM Switch

Name of

Interface Functional Description Amount

DC 9V Direct current power of 9V 1

Console Interface to control VGA, Keyboard and

Mouse connections

1

PC1-PC8 Interface for input VGA signal 8

The Interface described above on KVM Switch is shown in Figure 2-9.

KVM Switch Back Panel

DC 9V Console

PC8 PC7 PC6 PC5 PC4 PC3 PC2 PC1

Figure 2-9 Schematic diagram of KVM Switch

2.2.1.8. Router

Router is used to supplies route for LTE SS, TD-SCDMA SS, GSM SS, RF Switch Controller,

CE and System Managing Computer, so that all these equipments can communicate on internet

base on TCP/IP.

2.2.2. Hardware Connection

2.2.2.1. RF connection

The RF connection of SP8200 is shown as Figure 2-10 :

Page 22: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

16

SP8300

SP8300

KVM Switch

POWER

Switch Controller M4400

Switch Controller M4400 FILTERS

RRM_UE_TRX

RRM_UE_RX

Switch Controller M4400 FILTERS

Switch Controller M4400

UE_RX UE_RX/TX

CE

PowerOUT-RF2-IN/OUT

SP8300G

PresetOUT-RF1-IN/OUT

VGALAN

System Manage Computer

SP6300T

Figure 2-10 Schematic diagram of SP8200 RF connection

2.2.2.2. LAN connection

LAN connection of SP8200 is shown as Figure 2-11:

Page 23: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

17

CE

SP8300 KVM Switch

SP8300

POWER

Switch Controller M4400

Switch Controller M4400 FILTERS

SP6300T

SP8300G

LAN

VGALAN

System Manage Computer

Figure 2-11 Schematic diagram of SP8200 LAN connection

2.2.2.3. Video and Mouse connection

Video, Keyboard and Mouse connection of SP8200 is shown as 2-12:

SP8300

KVM Switch

SP8300

SP6300T

CE

Switch Controller M4400

UE_RX UE_RX/TX

RRM_UE_TRX

RRM_UE_RX

Switch Controller M4400 FILTERS

SP8300G

LAN

VGALAN

System Manage Computer

Figure 2-12 Schematic diagram of SP8200 Video,Keyboard and Mouse connection

Page 24: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

18

2.2.2.4. Clock and Sync signal connection

Clock, Sync connection of SP8200 is shown as 2-13:

SP8300KVM Switch

SP8300

SP6300G

POWER

Switch Controller M4400

Switch Controller M4400 FILTERS

CE

SP8300G

VGALAN

System Manage Computer

Figure 2-13 Schematic diagram of SP8200 Clock Sync connection

2.2.2.5. AT connection

AT connection of SP8200 is shown as Figure 2-14:

SP8300 KVM Switch

POWER

Switch Controller M4400

Switch Controller M4400 FILTERS

SP8300

SP6300T

CE

SP8300G

System Manage Computer

USB

USB

Figure2-14 Schematic diagram of SP8200 AT connection

Page 25: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

19

2.3. System Software

2.3.1. Composition of Software

The software running on hardware is shown as follow:

Table 2-3 Run environment and functional description of SP8300 system software

No. Hardware Software Description

1 SP8300

TS Manager User’s main interface, controlling

the operation of test cases

Edit Para

Parameter editor, editing key

parameters and taking effect during

the test

TC Tracer

Track the real-time log of the test

cases and TTCN log off-line

reading

2 R&D Environment

PC

IBM Rational System

Tester 3.3

Develop test cases for TD-LTE

Protocol Test (The third-party

software)

Microsoft

Visual studio 2008

Executable test suite obtained

through compiling testing script

with TTCN-3 (The third-party

software

Log Tracer Display and record the logs in the

SP8300

Page 26: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

20

3. SP8300 Software Instructions

3.1. TS Manager

3.1.1. Introduction

TS Manager offers the user with powerful and artistic diagram interface, so as to

manage the operation of all test cases in the test suite and display the results. TS

Manager Interface contains several windows, dialog box, toolbar and menu. Its

interface is similar to that of WINDOWS application program, so those who are

familiar with WINDOWS operation can handle it more proficiently. For example,

click the right mouse button, the background menu will immediately popup.

3.1.1.1. Software Installation

3.1.1.2. Main Interface

The initial main interface of TS Manager, c

Figure 3- 1 Initial main interface of TS Manager

The above interface shown in 错误!未找到引用源。 is not equipped with the

function of managing and running the test cases. Therefore, you have to load this

interface with the test suite provided by the manufacturer, then you can enter into the

main interface display for the test case’ management and operation of TS Manager,

as shown below:

Page 27: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

21

Figure 3- 2 Main interface of TS Manager

3.1.1.3. Window of Main Interface

Main Interface of TS Manager includes five windows, MSC, Message info, Test

suite and test plan list window, Test case execution window and the information

output window:

Test suite and test plan list window

Test suite and test plan list window lies in the left side of the main interface,

displaying the Multiple Test suite and test suite of multiple test plans. The test suite

can be folded or unfolded to show detailed information.

Test case execution window

Test case execution window lies in the middle of the upper part of the main interface,

display all test cases information in the current test plan. Current test case

information includes execution iterations, test case names and verdict times (pass,

fail, inconclusive).

Information output window

Information output window lies in the middle of the bottom part of the main

interface, real-time displaying the interior running status of the test suite and test

plan, for example, the loading information of test suite or the error prompt message

of project operation. During operation of test case, this window real-time display the

execution status, LOG message and verdict result.

MSC window

MSC window lies in the right side of the top part of the main interface,Real-time

display to execution the test case in SS and UE interactive signaling,Real-time

display refresh SS and UE interactive signaling,once again the test case execution

Page 28: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

22

empty MSC window signaling.

Message info window

Message info window lies in the right side of the bottom part of the main interface,

Real-time display to execution the test case in SS and UE interactive signaling, click

on the one signaling IE content displayed in the message Window.

3.1.1.4. Menu of Main Interface

There are two options in the menu of TS Manager’s main interface, i.e., File and

System, as shown below:

Figure 3- 3 Menu of TS Manager’s main interface

These options will be elaborated respective as follows.

File

Click File in the menu, you will see the following dropdown list:

Page 29: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

23

Figure 3- 4 File of TS Manager file

The functions of the items in the dropdown list of File are as follows:

New: create test plan.

Opensuit: to load with test suite file.

Recent Files: current unfolded file.

Exit: shut down TS Manager.

Settings

Click Settings in the menu, you will see the following drop-down list:

Page 30: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

24

Figure 3- 5 Settings of TS Manager

The function of the item in the drop-down list of System is as follows:

【System Settings】Open settings config dialog

3.1.1.5. Toolbar

The toolbar lies in the bottom of main menu bar, the left of which is standard toolbar

and the right is test case toolbar. The standard toolbar in the Open suite is always in

the activated state; however, the test case toolbar is initially in a prohibited state,

until it is successfully loaded with test suite project, that is, its state is varied with the

operation situation, as shown in below figure:

Page 31: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

25

Figure 3- 6 Toolbar of TS Manager

Standard toolbar

Standard toolbar of TS Manager is shown in Figure3-1:

Figure 3- 7 Standard toolbar of TS Manager

Functions of corresponding button:

Open Suit: loading test suite file.

New Plan: add test plan to in testsuite

Test case toolbar

Test case toolbar of TS Manager is shown in Figure 3-8:

Figure 3- 8 Test case toolbar of TS Manager

Function of each button:

Run/Stop: Run/Stop test case.

Save: Save the number of test cases executions.

ModifyProj: Modify note and testcases number in the test plan.

Page 32: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

26

Edit Para: Edit common parameters of testcase.

RFInfo: Display RF information.

LogTracer: Start Log Tracer.

Report: Open the report directory.

3.1.1.6. Background Menu

In the test suite and test plan list window of TS Manager, click the right mouse

button, you can open and use the background menu of TS Manager, thus you can

swiftly apply the usual functions of the test suite and test plan list, for example, open

test, edit, delete, as shown below:

Figure 3- 9 Background menu of TS Manager

3.1.2. Instructions

3.1.2.1. Start TS Manager

Double click the shortcut on desktop of TS Manager, Then you can start TS

Manager software.

3.1.2.2. Load with Test Suite File

There are two ways of loading test suite project file.

Click File → Open menu item and open the file selection dialog box. In the

36.621-3_Efolder, select and open 36.621-3_E.sptp;

Page 33: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

27

Click the Standard toolbar button , open the file selection dialog box,

In the 36.621-3_E folder, select and open36.621-3_E.sptp;

3.1.2.3. Remove Test Suite File

Select the test suit’s name which you want to remove, click the right mouse button,

popup background menu. Select Remove in the popup menu, you can remove the

test suite.

3.1.2.4. Open with Test Plan

There are two ways of open test plan:

Load with test suite file complete,right click test plan’name with the mouse→Open

menu item and selection open.

Load with test suite file complete,double click test plan’name with the mouse;

3.1.2.5. ADD Test Plan

Load with Test Suite File complete, Click the Standard toolbar button , open

the new plan dialog box, select test case in the structure tree.

3.1.2.6. Delete Test Plan

Test Suite on display test plan, select the test plan’s name which you want to delete,

click the right mouse button, popup background menu. Select Delete in the popup

menu, you can delete the test plan.

3.1.2.7. Edit PICS/PIXIT Parameter

Load with test suite file complete, click the button of in toolbar to open

PICS/PIXIT parameter dialog box. The user can edit PICS/PIXIT parameters

according to the specific requirements when running test case.

See Para Editor software instructions and the editing method of PICS/PIXIT

parameters in the section on 3.2.2.

3.1.2.8. Select Test Case

The operation procedures are as follows:

1. Load with test suite file complete

2. Open with test plan

3. click the button of in toolbar to open modify project(show test

plan’name ) dialog box;

4. Unfolded the nodes for test cases in the test suite structure tree to display all the

Page 34: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

28

sequence of executive test cases;

5. Click the check box in front of the test case name to be selected, a check mark

will appear in the check box which indicates that the test is selected. You can

select one or more test cases.

6. Click Save button

Figure 3- 10 Select Test Case interface

3.1.2.9. Set Iterations of Test Cases to be Executed

Steps are as follow:

1. Load with test suite file complete.

2. Open with test plan.

3. Click the target test case, its Execution information will be displayed in the right.

4. Click the line of Excution iterations parameter in the test plan window of test

case, the parameter editing box appears, set the value of iterations parameter.

5. Click the button of in toolbar, to complete the set up.

6. If the value you set is in line with the constraints of this test case iterations, the

value of Excution Iteration will show the set value, the number of the test

iteration case is set up successfully; otherwise, Excution Iterations will still show

the original value, the number of the test iteration case will set unsuccessfully

and popup system warning dialog box.

Page 35: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

29

Figure 3- 11 Set the number of the test case iteration

3.1.2.10. Run the Test Cases

Steps are as follows:

1. Click the Test Cases toolbar button , you can start and run test cases in the

test plan in proper sequences;

2. Running a single of test cases, right click test case’name with the mouse,open

menu item and select Run test case’name. "Download FPGA…" is displayed

when the hardware and software environment is being prepared; "start running"

is displayed when it is in normal operation; in the end of the run, it displays the

results of the arbitration from the test cases, using "PASS", "FAIL",

"INCONCLUSIVE" , as shown below:

Page 36: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

30

Figure 3- 12 Run test case

3. After starting to run the test cases, the output window of the message output all

the process information of the test cases, as shown below:

Figure 3- 13 Information output window

After running the test cases, TS Manager generates the report file and Log file for

the test case.

3.1.2.11. Close TS Manager

Close TS Manager by the following two methods:

1. Click File→Exit menu item;

Page 37: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

31

2. Click the icon button in the top right corner of the main interface window in the

TS Manager.

3.1.2.12. Set UE Control Type

The ue control type include voltage resource control called POWER Control and AT command

control.

1. Set the POWER Control type

After the system initial ok,click the System/System Config and choose the POWER type,as

fllows:

picture 3- 14 System Config

2. Set the AT Command Control type

After the system initial ok,click the System/System Config and choose the UE type,as fllows:

Page 38: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

32

picture 3- 15 System Config

3.2. Edit Para

3.2.1. Introduction

Edit Para is a sub-window of TS Manager, main functions are as followed:

Edit various types of parameters, such as BOOLEAN type、ENUMERATE

type、BITSTRING type、OCTETSTRING type、HEXSTRING type and

INTEGER type etc, and can check reasonablely;

The function of searching and locating parameters conveniently;

Edit parameters according to demand.

3.2.1.1. Main Interface

The initial main interface in Edit Para as shown below:

Page 39: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

33

Figure 3- 14 Main interface of Edit Para

Private parameters Edit Para as shown below:

Figure 3- 17 Private parameters

3.2.1.2. Window of Main Interface

ID text: Display the ID of the PICS/PIXIT parameter.

Parameter text: Display the name of the PICS/PIXIT parameter.

Value text: Display the value of the PICS/PIXIT parameter. Click value bar you

can edit the Value of the parameter.

Page 40: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

34

Search bar: Search the target PICS/PIXIT parameter by inputting the search

information in the blank bar.

Default button: Restore default parameter value.

Save button: Save the edited value of parameter and refresh Parameter list.

Cancel button: Cancel editing.

3.2.2. Instructions

3.2.2.1. Open Edit Para Window

Click button of TS Manager toolbar to open EditPara Window. As shown in Figure

3-16.

3.2.2.2. Edit Value of PICS/PIXIT Parameter

To modify value of PICS/PIXIT parameter, click on the value bar of the parameter,

the "value" of this line will be under editing status.

Figure 3-18 Edit Value of Parameters

Users modify the parameter value according to their demand, the edit box disappear

when the Enter key is pressed. Parameters return to non-editing state. If the modified

parameters value is consistent with the definition range, the interface display the new

value, marking the modification is accepted. If not, the parameter’s value remains

initial value.

Page 41: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

35

3.2.2.3. PICS/PIXIT Parameters Return to Default Values

When users modified the parameters, if they want to return parameters to default

values, they should click the button on the left bottom of the interface.

3.2.2.4. Search And Locate the PICS/PIXIT Parameter

User can input the parameters information to be checked in the Search Bar, Edit Para

marks all parameters accorded with the data, according to the input parameter

information, to achieve the functions of search and locate. The property of parameter

is defaulted to the current options of Search dialog box, while check box has no this

option.

3.3. Log Tracer

3.3.1. Introduction

Log tracer has the function that sending log information and displaying anslysis, in

which the sender can provide a good interface, well embedded in the client’s

application. The receiver that primarily as a stand-alone software application runs on

separated machine.

3.3.1.1. Main Interface

Log tracer’s initial main interface is shown as below:

Figure 3- 19 Log Tracer’s Main Interface

Page 42: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

36

3.3.1.2. Window of Main Interface

Log tracer consists of four windows, namely View list window, Message list

window, Tree list window and Message window.

View List Window

View list window is at the left top of the main interface. All views are displayed in

the form of tree view. The main categories are: Raw, Filter and Merge.

Message List Window

Message List window is on the right top of the main interface, display all message

that view contain.

Tree List Window

Tree List window is at the left bottom of the main interface, display the selected

message’s structure of Message List area. The value of each node in the tree can be

edited and modified with color-coded nodes.

Message Window

Message window is at the right bottom of the mian interface, display the selected

massage.

3.3.1.3. Menu of Main Interface

Log tracer’s main menu has four parts, namely File, Edit, Control, and Options.

Shown as below:

Figure 3- 20 Log Tracer’s Main Menu

These options will be introduced as follows:

Page 43: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

37

File

Click the File option on the menu, the drop-down list appears as below:

Figure 3- 21 Log Tracer’s File Menu

The function of each option of File’s drop-down list is described as below:

Open: Pop up the file selecting dialog, open the selected .log file (*. splog). It

supports to open multiple files same time.

Save Log: Save the seleted message in Message List to the clipboard, in the form of

XML, for other uses.

Csv Convert: Convert the spcsv file to csv file opened in the form of xls.

Export to XML: Pop up the file save dialog, export the selected single or multiple

messages in Message List, or the selected nodes in tree structure area, in the form of

XML.

Recent Files: Display the recently opened .log files on the righe side of the

sub-menu.

Exit: Close Log Tracer.

Edit

Click the Edit on the menu, the drop-down list appears as below:

Page 44: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

38

Figure 3- 22 Log Tracer’s Edit menu

The function of each option of Edit’s drop-down list is described as below:

Copy: Copy the seleted message in Message List.

Filter: Click this option, edit the filter condition in the filter dialog.

Select All: Select all message in Message List.

Invert Select: Invert Select

Hex to Dec: Select the Hex of displaying information in Tree List area.

Control

Click the Control menu, the drop-down list appears as below:

Page 45: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

39

Figure 3- 23 Log Tracer’s Control menu

The function of each option of Control menu’s drop-down list is described as below:

Start: Start to receive messages, and set status of the corresponding button on Tool

bar (Start: not available; Stop: available).

Stop: Suspend to receive log message (sender continues to send, but the receiver

throw away the received message), and set status of the corresponding button on

Toolbar (Start: available; Stop: not available).

Clear: Clear the existed log messages.

Options

Click the Option menu, the drop-down list appears as below:

Page 46: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

40

Figure 3- 24 Log Tracer’s Options menu

The function of each option of Option’s drop-down list is described as below:

Color Config: Configure background color of different level message and refresh

the current display.

Dictionary: Display all name, version number and current use status of the

dictionary that match the name.

Decoder: Specified the library function edition that supported by ASNI and CSNI

decoding.

Authorize Config: Configure Authrorize IP address.

SystemInfo Config: Configure system information.

Lost Messeges: Display the lost message serial number of each session.

Columns Config: Configure columns information display on the interface.

3.3.1.4. Toolbar

Log tracer’s Tool bar is at the top of the main interface, shown as below:

Page 47: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

41

Figure 3- 25 Log Tracer’s Tool Bar

The function of each button of the Tool bar is described as below:

Figure 3- 15 Log Tracer’s Tool Bar

1. Start: Start to receive log message.

2. Stop: Suspend to receive log message (sender continues to send, but the receiver

throw away the received message), and set status of the corresponding button on

Tool bar (Start: available; Stop: not available).

3. Refresh/UnRefresh: The log messages refresh or keep static by real time.

4. Clear All: Clear the existed log messages.

5. Open: Pop up the file selecting dialog, open the selected .log file (*. splog). It

supports to open multiple files same time.

6. Save: Save the current log information.

7. Filter: Click this button, edit the filter condition in the filter dialog.

8. Searching box: Enter the searching message in the Searching box of Tool bar, and

click the Searching button in the designated area to find the specified string. Then

the first object is highlighted.

9. Find Prev: Click this option, highlight the last matching message list row.

10. Find Next: Click this option, highlight the next matching message list row.

Page 48: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

42

11. Csv Convert: Convert the spcsv file into csv file.

3.3.1.5. Status Bar

Log tracer’s Status bar is at the bottom of the main interface. It displays connect

status, control status, socket connecting number, message number of the software.

Shown as below:

Figure 3- 26 Log Tracer’s Status Bar

3.3.2. Instructions

3.3.2.1. Start Log Tracer

By path: Tsmanager\Release_final\SSPRealease\TSManager\PSInterface\PS\Bin,

open the StarPoint_Universal_LogTool_Cfg.ini file, set the computer IP address of

Log Tracer’s Tool bar under the IP Address of [TracerIP]. After that, then can start

Log Tracer’s Tool bar, which record and display the log message of the current

running test case.

Click Log Tracer’s Tool bar button, or click Control→Start menu, start to

receive log message.

3.3.2.2. Load Log file

1. Click Log Tracer’s Tool bar button, or click File→Open menu, pop up the

File open dialog:

2. Select to load the log file (*.splog) in the file dialog. After the file is

successfully loaded, the interface is shown as below:

Page 49: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

43

Figure 3- 27 Log loaded successfully interface

3.3.2.3. Save Log file

If you want to save message in the Message List window for log file, click

File→Save Log menu.

3.3.2.4. Set Filter condition

Click Log Tracer’s Tool bar button, or click Edit→Filter menu, then you can

open Filter dialog, edit filter condition. Shown as below:

Figure 3-28 Log Tracer Filter dialog

Page 50: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

44

The instruction for use of Filter dialog is described as below:

The name of the Filter is on the left of Filter interface’s display area. The foreground

color of Filter of the Filter’s sub-nodes displayed in the main interface’s View List’s

display area, is black, the color of the foreground that not shown is gray. There is no

selected default Filter in Filter list. It doesn’t support multiple selections.

When selecting a Filter, this Filter’s condition will display in the right side of the

corresponding item. The other projects can be modified except for Filter name.

Filter Name: Default display Filter’s name [Filter_NNN] (N stands for number),

which can be edited. It cannot be edited when display the exited name of Filter.

Start Time: Display the starting time of Filter. Default display time is system time.

The format is yyyy/MM/DD HH:mm:ss.

End Time: Display the ending time of Filter. Default time is system time. The

format is yyyy / MM / DD HH: mm: ss.

Session Fliter: Display ID of all Session, sorted by name. The default Session is the

first.

Priority: Display all priority, sorted by name. The default priority is the first.

Viewable: Indicate that whether the Filter is displayed in sub-node of [View List] in

the main interface.

Filter interface contain three buttons, namely Delete, Save, Close.

Delete button: Delete the selected filter in Filter list, and clear Filter name in Filter

condition display area.

Save button: Save the condition of recent display Filter in Filter condition display

area, and refresh Filter list.

Close button: Close this interface, and refresh the sub-node of Filter in View List of

the main interface.

3.3.2.5. Convert to Csv file

If more detail of log is needed, you can convert the spcsv file into csv file.

Load spcsv file

Click the button on the Tool bar, or File→Csv Convert menu, load spcsv file by

path C:\Log\LogData, Shown as below:

Page 51: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

45

Figure 3- 29 Loading Spcsv file window

Select the spcsv file according to demand, then click Open button, the spcsv file will

convert into csv file. If the seleted spcsv file was not wanted to be converted, you

can click Cancel button.

Load Csv file

Csv file is another kind of log containing larger data information and more detail

information. You can view the csv file converted into by the spcsv file by path:

C:\Log\LogData, shown as below:

Figure 3- 30 Loading Csv file window

Open Csv file

Double click the target file to open the .csv file in the form of .xls; Aslo you can

click right mouse and click open to view the file, shown as below:

Page 52: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

46

Figure 3- 31 Csv File Opening Window

3.3.2.6. Configure the background color

Click Options→Color Config Menu, open Color Config dialog, set the background

color of different message. Shown as below:

Figure 3- 32 Log Tracer’s Color Config Dialog

Priority text: Display the name of Priority. When select any Priority, the message of

Priority will display in the bottom [Priority Color edit area] corresponding items.

Color text: The background color is the Priority’s.

Priority text editing area: Display name of Priority. The default is empty and it can

not be edited.

Color button: The default background color is the interface’s color. Click and pop

up the Color Chooser dialog, select the new color, and the background color will

change into a new color.

Save button: Save the color configure information.

Close button: Close the interface.

Page 53: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

47

3.3.2.7. View Dictionary Version Number

Click Options→Dictionary menu, open Dictionary dialog, and view the version number, shown

as below:

Figure 3- 33 Log Tracer’s Dictionry Manager

The introduction for use of Dictionary dialog is described as below:

Dictionary text: display name of the Dictionary dll.

Version text: Display the version number of the Dictionary dll, namely the last 6

figures in underscore of the Dictionary dll.

Close button: Close the interface.

3.3.2.8. Close Log Tracer

There are two ways to close Log Tracer:

1. Click File→Exit menu;

2. Click the Close icon button, on the up right corner of the main interface window.

3.4. UE Controler

3.4.1. Introduction

SP8300 UE controller software is installed on the remote PC. UE controller receives AT

commands from TS Manager when test case running, and sends these AT commands to UE.

3.4.1.1. Main Interface

UE controller’s initial main interface is shown as below:

Page 54: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

48

Figure 3- 34 UEController’S main interface

3.4.1.2. Window of Main Interface

UEController software main interface contains five window, respectively is Command display

list Windows,, Mode Windows, Authorization Windows, COM Settings window, Switch Settings

window and Input window.

Command display list Windows:

on the top of the UE controller main interface, display the input message and the message

from TsManager.

Figure 3- 35 Command display list Windows Mode Windows

Page 55: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

49

Select online mode or offline mode for UE Controller.

Figure 3- 36Mode Windows

Authorization Windows:

Set the IP address and Port number of the authorization server.

Figure 3- 37Authorization Windows

Click on the【SET】 button, appear as follows interface:

Figure 3- 38Authorization Windows

Click the【OK】can save.

COM Settings window:

COM Settings window provide Settings UE used serial identification and serial interface

baud rate of the user interface. Click on the【SET】 button, can according to users in the

COM Port edit box SET UE serial identification and Bit Rate edit box SET communication

baud Rate, the initial serial Port, and the user setting write configuration files saved, as

the next open UEController software default serial setting.

Figure 3- 39 COM Settings window

Page 56: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

50

Switch Settings window:

Switch Setting window to provide custom shutdown and startup AT instruction function,

click the 【SET】 button can save Settings, as below:

Figure 3- 40 Switch Settings window

Input window:

Input window can again the drop-down box manual Input or choose AT instruction, click

on the【Send】button can Send UE, as below:

Figure 3- 41 Input window

3.4.2. Instructions

3.4.2.1. Start UE controller

By path: Program Files\SP6300 UE controller\BIN_R\UECtrl.INI, you can set the [UEInfo] port

and mofify the checkout information of AT command. After setting, you should restart UE

controller.

Double click the shortcut of on desktop of UE controller, then you can start UE

controller software.

3.4.2.2. Set the parameters in the Com Settings window

User according to the instructions provided by the UE manufacturer, input serial of UE

automation testing support in the COM Port edit box logo, and select the appropriate baud rate,

click the [SET] button, UEController start serial port initialization process. The serial

initialization the success, Command display list Windows displays "COM Initializatin

Succeeded!", As shown below, otherwise, COM Initializatin Failed! "

Page 57: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

51

Figure 3- 42 Initialization com results suggest that information

3.4.2.3. Close UE controller

Close UE controller software by the following two methods:

Click the icon button in the top right corner of the main interface window in the UE controller

software.

3.5. Driver

Driver is used to drive the hardware of the system,you should load it on system

simulator not on the PC.

Before the TS Manager open, you should start the driver firstly.

Load driver: Open workpath_cell file, then double-click lte_ss_diver.exe file to

start the diver, as shown below:

Page 58: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

52

Figure 3- 43 Loading driver

Open diver: If the driver load successfully, it appears as below:

Figure 3- 44 Interface of driver

Display the information of opening TS Manager: After the driver load

successfully, you can open TS Manager on PC, the interface of the driver is shown as

below:

Page 59: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

53

Figure 3- 45 Information of opening TS Manager

Display the information of running test case: If the test case running

successfully on TS Manager.The interface of driver display the following

information.

Figure 3- 46 Information of running test case

Close driver: Click the button on the right top of interface to close the driver.

Page 60: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

54

4. SP8300 Test Procedure

1. Starting up

After all the modul of SP8200 pluged in, which inconclude LTE SS01,LTE SS02,

Switch Controller M4400,Switch Controller M4400 FILTERS,SP6300T,

SP8300G,CE,KVM Switch), the power indicator light shows red. Press Power

botton on the front panel, the indicator light turn to green, then SP8200 starts.

2. Start driver

Double press Control button to swich the interface of LTE SS02, and open

workpath_cell2 file, then double-click lte_ss_diver.exe file to start the diver;

On PC, view the WithCE and WithRFS by path of workpath\8200_ss_config.ini. If

the value is 1, it means the equipment is connected, if the value is 0, it means the

equipment is not connected,

On PC, View the IP adress ipaddress=SS1 IP|SS2 IP,(SS1 IP is LTE SS01 10M IP

adress,SS2 IP is LTE SS02 10M IP adress)by path workpath \ drv_config.ini

3. Start TS Manager

Open workpath file, then double-click TS Manager.exe file to start the TS Manager;

4. Establish New Plan

Click NEW Plan button, load adapter file, and select the test suite or the test case file

to load in the dialog.

5. Run the test case

Select the test suit, Click Run button in Tool bar, then you can run the test cases

which selected in the NewPlan.

6. Cease to run test case

Click Stop button in the Tool bar, then you can cease to run test case.

7. Power off

Click Start → Turn Off to power off SP8200, when no signal is shown on the

screen, press Power botton. Please don’t change the order of power off.

Page 61: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

55

5. SP8200 and SP6200 Integrated

System

5.1. System Introduction

5.1.1. System Overview

Along with the development of LTE product, the SP8200 and SP6200 integrated

system is established on the unit platform. SP6200 is integrated on SP8200. SP8200

control the operation of SP6200 and SP8200, dispatching of the two system. SP8200

displays the Log information of the test case of SP8200 and SP6200 at the same time.

User can edit the test plan of SP8200 and SP6200 on SP8200, and the test case of

SP8200 and SP6200 can run in the meantime, so the RRM test of TD-SCDMA and

LTE test can be done separately meanwhile, multi UE can be connected at the same

time.

The SP8200 and SP6200 system is composed of software and hardware which is

shown as Table5-1:

Table5-1 Software and Hardware of SP8200 and SP6200 integrated system

Hardware

Hardware system of SP8200(referrence 2.2 Section)

SP6200 Hardware(referrence SP6200 TD-SCDMA Terminal

Radio Resource Management Conformance Test System user

manual)

Software

Software of system

managing computer

TTCN-3 edit/compile sofeware

System managing software

Log analyzing software

TD-SCDMA SS software

Process managing software

Communication interface software

L1,L2 software of TD- SCDMA

LTE SS software

Process managing software

Communication interface software

L1 and L2 software of LTE

RF switch controller software of LTE RRM

SP6200 software system(referrence SP6200 TD-SCDMA Terminal

Radio Resource Management Conformance Test System user

manual)

Auxiliary

Cable

RF cable

10MHz clock cable

Page 62: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

56

Trigger cable

5.1.2 Systemic Framework

37 U

1 U

1 U

1 U

1 U

M4400-M

SP8300

SP8300

1 U

2 U 2 U

Channel

Emulator

(SP8200 Side)

1 U

SP6300T

SP8300G

37 U

1 U

1 U

1 U

1 U

SP6200-SSP

1 U

1 U

1 U

1 U

1 U

2 U

M4400-S

Aeroflex

6103G-Server

1 U

1 U

1 U

Channel Emulator

(SP6200 Side)

M4300

37 U

1 U

1 U

SP6200-RAP

SP6200-RAP

1 U

1 U

1 U

1 U

1 U

1 U

1 U

2 U

5 U Aeroflex

6103G

2 U

1 U

1 U

Figure 5- 1 Systemic Framwork

5.2. Function Introduction

SP8200 and SP6200 integrated system uses the interface of SP8200, by means of Mouse and

Keyboard to control the whole system, the main functions of this system are adding test plan of

SP6200 to SP8200 and adding interface of running test case.

SP8200 uses list to manage test suit and test plan. The new main functions of

SP8200 and SP6200 integrated system are in Table5-2:

Table 5-2 New function of SP8200 and SP6200 integrated system

modul Instruction of function

TC Plan View Add SP6200 test plan management on TC PlanView

TS Manager

NewPlan Dialog

Add SP200 test case editing, which list all the test cases of test suit in tree

stucture

TS Manager

Manage View

Add SP6200 test case running window, which edit the test case running

times and display the running result

Page 63: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

57

Message Pane Add test case information of SP6200 in OUTPUT window

TS Manager

Para Editor

Add SP6200 parameter edit window and SP6200 PICS/PIXIT list setting

window

Test case running Add SP6200 test case control modul, the test cases of SP6200 and SP8200

can running side by side

Log managing Add SP6200 Log managing function

5.2.1. Test Plan Management

SP8200 list all the test case of SP8200 by tree structure, which classify by the feature of test case.

User edit test plan by choosing test case.

SP6200 uses the same interface as SP8200, and the same way of editing test plan. As the separate

test suit, the test cases of SP8200 and SP6200 are separate, which can not display on the same

interface at the same time. The interface of opening the test suit is shown as below:

Figure 5-2 Test plan editing window

User edit the test plan of SP8200 or SP6200 separately, then save the test plan separately, and

display the test plan on the test suit managing interface. The interface of editing test plan is

shown as below:

Page 64: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

58

Figure 5-3 Test plan editing interface

After the test plan saved, the test suit’s label of SP8200 and SP6200 seprately display on the test

suit managing interface, which is shown as below;

Figure 5-4 Display of added Test plan interface

Page 65: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

59

5.2.2. Test Case Runnning Window

Test case running window mainly discrib the status of test case running, times of running test

case, display status information of test case. SP8200 manage test case running window by TAB,

each TAB page manage test case running window separately. All the test cases share Log

window and MSC window. After adding SP6200, a TAB manage test case running window, Log

window, MSC window. For each test case there is a separate window to support outputting test

case information. Test case running window is shown as below:

Figure 5-5 Test case running interface

In the figure,the blue part is the lable of TAB, below the TAB is the test plan window, Which

displays the basic information of all the test cases in the test plan.

OUTPUT window is the test case running information list. While the test case running, the

OUTPUT window displays the process information in real time.

The MSC window is on the right, which display the sequence diagram of primitive while test

case running, the time of sending primitive and the time of receiving primitive. The Message

Info window displays the stream of information.

After adding SP6200 on SP8200, each TAB page is related to test plan list window, OUTPUT

window, MSC window. There are different window resource on SP6200 and SP8200,which

make the information output normally.

5.2.3. Parameter Configure

Open Parameter Config window in System menu, when select System Config sub menu, the

parameter of SP8200 can be edited, when 6200 Para Setting selected, the parameter of SP6200

can be edited.

Page 66: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

60

The Syetem menu is shown as below:

Figure 5-6 System menu

Select PIS list and click Set.

Figure 5-7 Parameter configure window of SP6200

5.2.4. View Log Information

Both SP8200 and SP6200 have Log information, which is display in real time when test case

running. The Output window in TS Manager output the hyperlink of Log formation, which is

shown as below:

Page 67: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

61

Figure 5-8 Hyperlink of Log file on TS Manager interface

SP8200 supplies Log Tracer to view communication of low layer in realtime. Log Tracer also

display UTRAN information and information stream.

Log information of SP6200 is the communication of low protocol stack, Message Analyzer

supplies the result and analyzed result of the log.

Log of SP6200 send to the formulate catalogue of PC though remote port, Message Analyser is I

integrated in SP8200 interface. It can open the log file which upload to local from remote port.

The interface of Message Analyser is shown as below:

Page 68: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

62

Figure 5-5 Interface of Message Analyser

Message Analyser is used to open .msglog file.

SP6200 TC TRACER is used to analyze the Log file created by TTCN, TC Tracer is shown as

below:

Figure 5-6 Interface of TC TRACER

Page 69: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

63

TC Tracer is used to open TTCN log file.

SP6200 remote log use network mapping, which map the local environment of SP6200 to PC of

SP8200.

SP8200 interface is added to display the REPORT link of SP6200, and SP8200 display the log of

each test case in OUTPUT window, REPORT file link. Which is shown as below:

Figure 5-7 Interface of SP6200 REPORT

Page 70: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

64

6. Matters Need Attention

6.1. Operation Prohibited

The following operations may result in the display appears blank screen.

1. Cut off the power supply before the SP8300 instrument has been completely

turned off.

2. Press the Power button before the operating system has been properly shut down.

3. Plug or unplug the monitor's VGA cable before the SP8300 instrument has been

completely turned off.

4. Severe vibration of SP8300 instrument.

6.2. General Suggestions

Try not to replace the monitor frequently. If you do need to replace the monitor,

please turn off the SP8200 first.

Page 71: SP6300 User Manual - starpointcomm.com introduction...E-UTRAN RRC idle status, mobile performance test under E-UTRAN RRC connected status, RRC connected mobile control ability test,

SP8200 LTE Terminal Radio Resource Management Conformance Test System User Manual

65

7. Maintenance and Technique Support

Any modification, maintenance or repair, must be performed by professional maintenance

personnel.

If you have any questions in the process of work, welcome to contact with our technique support,

our contact way as follows:

WEB: http://www.starpointcomm.com

TEL: 010-62304490

FAX: 010-62300393

EMAIL: [email protected]

ADD: 3/F, BuildingA, Wangjing Science Technology Pioneer Park No.2, Li Ze Zhong Er

Lu, Chaoyang District, Beijing, China

POST: 100102