Mormon Beginnings in Samoa: Kimo Pelio, Samuela Manoa and ...
Sound level meter DB 100 -...
Transcript of Sound level meter DB 100 -...
MicrophoneMicrophone................................... prepolarised electret condenser.Nominal sensitivity........................ 20 mV/Pa .
Sound level meter Standards......................................IEC 61672-1 Class 2 /
IEC 60651 Class 2 / IEC 60804 Class 2 Measured parameters................... L
A and L
Aeq
Other displayed parameters.......... LAFmax
, LAFmin
, LASmax
, LASmin
Frequency weighting..................... A Measuring range........................... 30-130 dB Time weighting.............................. slow, fastData integration time for L
Aeq..........from 1s to 15 min
Overload indicator......................... detected at the peak sound-pressure levelBacklighted display....................... graphic 128x64 pixels.
Adjustable contrast.Resolution..................................... 0,1 dBReference direction....................... microphone axisReference range............................30 - 130 dBReference level............................. 94 dBReference frequency..................... 1000 Hz
Environmental effectsStorage relative humidity............... 95 % RH max.Storage temperature......................from 0 °C to + 50 °C.Operating temperature.................. from -10 °C to + 50 °C.Humidity dependence....................in accordance with standard between 30
and 90%RH, reference being at 65%HR and 40°C.
Static pressure dependence..........According to class 2 requirementsStandards......................................IEC 61672-1 / IEC 60651 / IEC 60804Electromagnetical compatibility...... As per 89/336/CEE guideline
Power supplyBatteries........................................3 AAA or rechargeable batteries
(Rq: rechargeable batteries must not be recharged inside the instrument)
Battery life (at 20°C)......................30 hours min (with alkaline batteries)
Ouput
DB 100 sound level meter is reliable, easy to use and in accordance with metrology requirements. DB100 can measure :
- Sound-pressure level
- Time averaged or equivalent continuous sound pressure level
DO NOT PLUG USB cable. The output is not USB compatible, the plug is maintenance- and optional accessory-specific.
Sound-pressure level LA
as per two weighting times FAST or SLOW
Time averaged sound level LAeq
To be used for stable or slightly fluctuating sound sources.Sound-pressure level (L
A ) unit is dBA and L
Amax and
LAminvalues are saved.
To be used for fluctuating sound sources.Time averaged sound level (L
Aeq) unit is dBA with a
programmable integration time in minutes and seconds.
Sound level meter
DB 100
DESCRIPTION
TECHNICAL FEATURES
*Supplied with wind screen
LA measuring L
Aeq measuring Contrast Calibration About...
Screens
LA : Hold function
(During measurement)
LAmax
and LAmin
reset 1x
LAmeasurement 1x Slow time weighting
2x Fast time weighting
1x Hold
2x Re-start
From LA measuring screen
1x
From LA measuring screen
LAeq
measurement Go to LAeq
measuring screen
1x Start
1x
Reset 2x
Contrast settings
1x 1x Decrease
1x Increase
Backlight 1x 1x
Deactive2x
Active
Calibration 2x 1x Calibration value decrease of 0.1dB
1x Calibration value increase of 0.1dB
1x
French2x
EnglishLanguage 3x
FUNCTIONS (Once instrument is switched on)
Function keys (See table)
Erase and back to previous screen
Screen key (See table)
On/Off key
CTL 100 Acoustic controller
The acoustic controller allows DB100 functional check with a reference of 90 dB at 1000 Hz.
Wind screen
To protect the microphone against wind and dust.
174
mm
58 mm
32 mm
27 mm
« ^ » symbol indicates the detection of input overload, while « ^ » appears measures must not be taken in account.
NTa
ng –
DB1
00 –
19/
02/1
5 –
RC
S (2
4) P
érig
ueux
349
282
095
Non
-con
tract
ual d
ocum
ent –
We
rese
rve
the
right
to m
odify
the
char
acte
ristic
s of
our
pro
duct
s w
ithou
t prio
r not
ice.
DIMENSIONS ACCESSORIES (OPTIONAL)
QUICK START
LAeq
: Hold function(During measurement)
1x
Stop2x
Re-start3x
Start
Stop
The acoustic calibrator allows the checking and calibration of the DB 100 sound level meter with a reference of 94 dB at 1000 Hz
CAL200 Acoustic calibrator