SOTECH OPTIMA FC...Sotech Ltd 2 Traynor Way Whitehouse Business Park Peterlee County Durham SR8 2RU...
Transcript of SOTECH OPTIMA FC...Sotech Ltd 2 Traynor Way Whitehouse Business Park Peterlee County Durham SR8 2RU...
Versatile | Fully Independently Tested | Completely Secret Fixed | CWCT Tested and Certified
S O T E C H O P T I M A F C
Only the top cutout of eachpanel fully engages the carrierhook.
Panel security screw.
Datum
Top of slot
5mm
5mm
Lower hooks on same panelare spaced to leave a 5mmexpansion gap.
For s
lots
/hoo
ks c
trs s
ee n
otes
bel
owD
imD
im
Fac
e H
eigh
t
Top of slot
Face Height 951mm+ 100mm down from top of panel face150mm up from bottom of panel faceAdditionally equally spaced intermediate holes max 700cts
Face Height 401>950 100mm down from top of panel face150mm up from bottom of panel face
Face Height 251>400 50mm down from top of panel face100mm up from bototm of panel face
Only the top hole of each panel makes contact with a support hook, all other hooksare 5mm lower to allow for expansion.
Typical Slot Setout Info.
Hook Centres.3mm Solid Aluminium - 400mm ctrs.
(ACM is shown in the details above which also apply to 3mm solid Aluminium.)
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCHook Arrangement
FC-01 08.04.16
1:4 A
Sotech Optima FC | Solid Aluminium System Details
Contents
3. Hook Arrangement............................................................4. Vertical Joint Detail...........................................................5. Horizontal Joint.................................................................6. Base Detail........................................................................7. Coping Detail.....................................................................8. Vertical Window Interface..................................................9. Horizontal Window Interface..............................................10. External Corner.................................................................11. Internal Corner...................................................................12. Facade Abutment Detail....................................................13. Horizontal Joint On SIPS Wall Panel.................................14. External Corner On SIPS Wall Panel.................................15. Feature Channel Detail......................................................16. Intermediate Support.........................................................17. Vertical Movement Joint....................................................
Sotech Optima FC | ACM System Details
18. Hook Arrangement.............................................................19. Vertical Joint......................................................................20. Horizontal Joint..................................................................21. Base Detail........................................................................22. Coping Detail.....................................................................23. Vertical Window Interface..................................................24. Horizontal Window Interface..............................................25. External Corner..................................................................26. Internal Corner...................................................................27. Facade Abutment Detail.....................................................28. Horizontal Joint On SIPS Wall Panel.................................29. External Corner On SIPS Panel.........................................30. Feature Channel Detail......................................................31. Intermediate Support.........................................................32. Vertical Movement Joint.....................................................
2
(FC-01)(FC-02)(FC-03)(FC-04)(FC-05)(FC-06)(FC-07)(FC-08) (FC-09)(FC-10)(FC-11)(FC-12)(FC-13)(FC-14)(FC-15)
(FC-ACM-01)(FC-ACM-02)(FC-ACM-03)(FC-ACM-04)(FC-ACM-05)(FC-ACM-06)(FC-ACM-07)(FC-ACM-08)(FC-ACM-09) (FC-ACM-10)(FC-ACM-11)(FC-ACM-12)(FC-ACM-13)(FC-ACM-14)(FC-ACM-15)
Sotech Optima FC | Solid Aluminium System Details
Sotech Optima FC | ACM System Details
Only the top cutout of eachpanel fully engages the carrierhook.
Panel security screw.
Datum
Top of slot
5mm
5mm
Lower hooks on same panelare spaced to leave a 5mmexpansion gap.
For s
lots
/hoo
ks c
trs s
ee n
otes
bel
owD
imD
im
Fac
e H
eigh
t
Top of slot
Face Height 951mm+ 100mm down from top of panel face150mm up from bottom of panel faceAdditionally equally spaced intermediate holes max 700cts
Face Height 401>950 100mm down from top of panel face150mm up from bottom of panel face
Face Height 251>400 50mm down from top of panel face100mm up from bototm of panel face
Only the top hole of each panel makes contact with a support hook, all other hooksare 5mm lower to allow for expansion.
Typical Slot Setout Info.
Hook Centres.3mm Solid Aluminium - 400mm ctrs.
(ACM is shown in the details above which also apply to 3mm solid Aluminium.)
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCHook Arrangement
FC-01 08.04.16
1:4 A
3
(FC-01)(FC-02)(FC-03)(FC-04)(FC-05)(FC-06)(FC-07)(FC-08) (FC-09)(FC-10)(FC-11)(FC-12)(FC-13)(FC-14)(FC-15)
(FC-ACM-01)(FC-ACM-02)(FC-ACM-03)(FC-ACM-04)(FC-ACM-05)(FC-ACM-06)(FC-ACM-07)(FC-ACM-08)(FC-ACM-09) (FC-ACM-10)(FC-ACM-11)(FC-ACM-12)(FC-ACM-13)(FC-ACM-14)(FC-ACM-15)
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.
20
50
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
Panel ModulePanel Module
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
324
GasketOptional Colour Match Strip
15161718
1
56
8
7
21011 9 12 11 13
151814 17 16
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCVertical Joint Detail
FC-02 08.04.16
1:3 A4
3 2 4
1
56
8
7
21011
9
12
11
13
15
18
1417
1620
Cladding Zone
To Suit U Value
Top Hat
Facade Substrate & Weather Line
SFS to suit loads
Pan
el M
odul
eP
anel
Mod
ule
Bkt
Mod
ule
Sub
ject
To C
alcs
11
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCHorizontal Joint
FC-03 08.04.16
1:3 A
5
6
50
Cladding Zone
To Suit U Value
Top Hat
Facade Substrate & Weather Line
SFS to suit loads
Pan
el M
odul
e
Bkt
Mod
ule
Sub
ject
To C
alcs
Dead loadbracket
GroundworksBy Others
InsulationBy Others
MembraneBy Others
3 2 4
1
567
19
12
11
15
18
17
16
11
To S
uit
Insect Mesh. By Others.19
821011
9
13
14
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCBase Detail
FC-04 08.04.16
1:3 A
Cladding Zone
To Suit U Value
Primary Structure & Weather Line
Pan
el M
odul
eC
opin
g To
Sui
t
1
9
19
11
Coping Width
15
2
2
Wind loadbracket
13
16
17
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Anchor & Plug - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
Extruded Carrier Profile With Gasket - centres to suit loads.
12
Roof Membrane. By Others.
13
Insulated board. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
Top Hat - thickness to suit.19
3 2 4
567
8
10
Coping Joint3
Coping Intermediate Support
19
2
7
15
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCCoping Detail
FC-05 08.04.16
1:3 A
7
Cladding ZoneTo Suit U Value
Primary Structure & Weather Line
Pan
el M
odul
e
To S
uit D
etai
l
50
Wind loadbracket
Pan
el M
odul
eP
anel
Mod
ule
Wind loadbracket
19
1
20
19
17
16
18
15
9
1919
13
1
3 2 4
567
1
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
8 2 10 11
EPDM or similar. By Others.19
12 11
15
Indicative Window System
1
To S
uit D
etai
l 15x6 WeepHole
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCVertical Window Interface
FC-06 08.04.16
1:3 A
8
1
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
Panel Module To Suit Detail
50
20
912
19
13
1
1513181714
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
EPDM or similar. By Others.19
Indicative Window System
3 2 4
567
Flashing Fixing Option
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCHorizontal Window Interface
FC-07 08.04.16
1:3 A
9
1
Cladding Zone Facade Substrate & Weather Line
Panel ModuleTo Suit Module
20
9
13
1
6 57
1715
18
To S
uit M
odul
eP
anel
Mod
ule
13
12 11
14
50
Top Hat
To Suit U Value SFS to suit loads
2 43
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
EPDM or similar. By Others.19
Corner Pressing Option
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCExternal Corner
FC-08 08.04.16
1:3 A
10
1
Panel ModuleTo Suit Detail
20
9
16
32 4
1714
1211 14
1
13
15
Facade Substrate & Weather Line Cladding Zone
Top Hat
50SFS to suit loads To suit U value
EPDM or similar. By Others.19
65 7
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCInternal Corner
FC-09 08.04.16
1:3 A
11
To Suit Structure Tolerance
9
161718
14 13
15
Top
Hat
SFS
to s
uit l
oads
To s
uit U
val
ue
Faca
de S
ubst
rate
& W
eath
er L
ine
Cla
ddin
g Zo
ne
1
10 8
EPDM or similar. By Others.19
75
43 5
12
13
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCFacade Abutment Detail
FC-10 08.04.16
1:3 A
12
20
Cladding Zone
Top Hat
Facade Substrate & Weather Line
SIPS Panel
Pan
el M
odul
eP
anel
Mod
ule
17
16
EPDM or similar. By Others.19
15
3 24
12 11
6 57
821011
13
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
Insulated SIPS Panel. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCHorizontal Joint On SIPS Wall Panel
FC-11 08.04.16
1:3 A
13
Facade Substrate & Weather Line
SIPS Panel
Pan
el M
odul
eTo
Sui
t Det
ail
1
8
16
Top Hat
Cladding Zone
20
To Suit Detail Panel Module
15
EPDM or similar. By Others.19
6 57
2 43
11 1213
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
Insulated SIPS Panel. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCExternal Corner On SIPS Wall Panel
FC-12 08.04.16
1:3 A
14
To Suit Detail
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
3 2 4
1
5
8
7
21011
19 9 12 11
1514 17 16 18
Aluminium Pressing.19
1
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCFeature Channel Detail
FC-13 08.04.16
1:3 A
15
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
Support ModuleSupport Module
324
1
5
8
7
21011 9 12 11 13
151814 17 16
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCIntermediate Support
FC-14 08.04.16
1:3 A
16
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
Panel ModulePanel Module
324
1
5
8
7
21011 9 1211 13
15 1814 17 16
20
9
17
Breather membrane & VCLlooped to accommodatemovement.
12
Optima FC Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FCVertical Movement Joint
FC-15 08.04.16
1:3 A
17
Only the top cutout of eachpanel fully engages the carrierhook.
Panel security screw.
Datum
Top of slot
5mm
5mm
Lower hooks on same panelare spaced to leave a 5mmexpansion gap.
For s
lots
/hoo
ks c
trs s
ee n
otes
bel
owD
imD
im
Fac
e H
eigh
t
Top of slot
Face Height 951mm+ 100mm down from top of panel face150mm up from bottom of panel faceAdditionally equally spaced intermediate holes max 700cts
Face Height 401>950 100mm down from top of panel face150mm up from bottom of panel face
Face Height 251>400 50mm down from top of panel face100mm up from bototm of panel face
Only the top hole of each panel makes contact with a support hook, all other hooksare 5mm lower to allow for expansion.
Typical Slot Setout Info.
Hook Centres.ACM - 700mm ctrs.
(ACM is shown in the details above which also apply to 3mm solid Aluminium.)
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMHook Arrangement
FC-ACM-01 08.04.16
NTS A
18
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.
20
50
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
Panel ModulePanel Module
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
324
GasketOptional Colour Match Strip
15161718
1
56
8
7
21011 9 12 11 13
151814 17 16
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMVertical Joint
FC-ACM-02 08.04.16
1:3 A
19
3 2 4
1
56
8
7
21011
9
12
11
13
15
18
1417
1620
Cladding Zone
To Suit U Value
Top Hat
Facade Substrate & Weather Line
SFS to suit loads
Pan
el M
odul
eP
anel
Mod
ule
Bkt
Mod
ule
Sub
ject
To C
alcs
11
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMHorizontal Joint
FC-ACM-03 08.04.16
1:3 A
20
50
Cladding Zone
To Suit U Value
Top Hat
Facade Substrate & Weather Line
SFS to suit loads
Pan
el M
odul
e
Bkt
Mod
ule
Sub
ject
To C
alcs
Dead loadbracket
GroundworksBy Others
InsulationBy Others
MembraneBy Others
3 2 4
1
567
19
12
11
15
18
17
16
11
To S
uit
Insect Mesh. By Others.19
821011
9
13
14
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMBase Detail
FC-ACM-04 08.04.16
1:3 A
21
Cladding Zone
To Suit U Value
Primary Structure & Weather Line
Pan
el M
odul
eC
opin
g To
Sui
t
1
9
11
Coping Width
15
2
219
Wind loadbracket
13
16
17
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Anchor & Plug - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
Extruded Carrier Profile With Gasket - centres to suit loads.
12
Roof Membrane. By Others.
13
Insulated board. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
Aluminium Pressing - thickness to suit.19
3 2 4
567
8
10
Coping Joint3
Coping Intermediate Support
19
12
2
7
15
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMCoping Detail
FC-ACM-05 08.04.16
1:3 A
12
22
Cladding ZoneTo Suit U Value
Primary Structure & Weather Line
Pan
el M
odul
e
To S
uit D
etai
l
50
Wind loadbracket
Pan
el M
odul
eP
anel
Mod
ule
Wind loadbracket
19
1
20
19
17
16
18
15
9
1919
13
1
3 2 4
567
1
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
8 2 10 11
EPDM or similar. By Others.19
12 11
15
Indicative Window System
1
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMVertical Window Interface
FC-ACM-06 08.04.16
1:3 A
23
1
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
Panel Module To Suit Detail
50
20
912
19
13
1
1513181714
EPDM or similar.19
Indicative Window System
3 2 4
567
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMHorizontal Window Interface
FC-ACM-07 08.04.16
1:3 A
Flashing Fixing Option
24
1
Cladding Zone Facade Substrate & Weather Line
Panel ModuleTo Suit Module
20
9
13
1
6 57
1715
18
To S
uit M
odul
eP
anel
Mod
ule
13
12 11
14
50
Top Hat
To Suit U Value SFS to suit loads
2 43
EPDM or similar. By Others.19
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMExternal Corner
FC-ACM-08 08.04.16
1:3 A
25
1
Panel ModuleTo Suit Detail
20
9
16
32 4
1714
1211 14
1
13
15
Facade Substrate & Weather Line Cladding Zone
Top Hat
50SFS to suit loads To suit U value
EPDM or similar. By Others.19
65 7
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMInternal Corner
FC-ACM-09 08.04.16
1:3 A
26
To Suit Structure Tolerance
9
161718
14 13
15
Top
Hat
SFS
to s
uit l
oads
To s
uit U
val
ue
Faca
de S
ubst
rate
& W
eath
er L
ine
Cla
ddin
g Zo
ne
1
10 8
EPDM or similar. By Others.19
75
43 5
12
13
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMFacade Abutment Detail
FC-ACM-10 08.04.16
1:3 A
27
20
Cladding Zone
Top Hat
Facade Substrate & Weather Line
SIPS Panel
Pan
el M
odul
eP
anel
Mod
ule
17
16
EPDM or similar. By Others.19
15
3 24
12 11
6 57
821011
13
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
Insulated SIPS Panel. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMHorizontal Joint On SIPS Wall Panel
FC-ACM-11 08.04.16
1:3 A
28
Facade Substrate & Weather Line
SIPS Panel
Pan
el M
odul
eTo
Sui
t Det
ail
1
17
16
Top Hat
Cladding Zone
20
To Suit Detail Panel Module
15
EPDM or similar. By Others.19
6 57
2 43
11 1213
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
Insulated SIPS Panel. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMExternal Corner On SIPS Panel
FC-ACM-12 08.04.16
1:3 A
29
To Suit Detail
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
3 2 4
1
5
8
7
21011
19 9 12 11
1514 17 16 18
Aluminium Pressing. By Others.19
1
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMFeature Channel Detail
FC-ACM-13 08.04.16
1:3 A
30
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
Support ModuleSupport Module
324
1
5
8
7
21011 9 12 11 13
151814 17 16
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMIntermediate Support
FC-ACM-14 08.04.16
1:3 A
31
To S
uit U
Val
ueS
FS to
sui
t loa
ds
Cla
ddin
g Zo
ne
Top
Hat
Faca
de S
ubst
rate
& W
eath
er L
ine
Panel ModulePanel Module
324
1
5
8
7
21011 9 1211 13
15 1814 17 16
20
9
17
Breather membrane & VCLlooped to accommodatemovement.
12
Optima FC-ACM Panel. Finish to suit project.Self Drill Fastener(Ejot JT4-ZT-4-4.8x19).
345678 Nvelope Handsfree Bkt - to suit zone & ctrs to suit loadings.
Tek Fixing - type to suit substrate material. By Others.
Insulation - thickness & type to suit specification. By Others.
Top Hat - material to suit span. By Others.
Isolator.9
Breathable Membrane. By Others.
10
Cemetitious Board (or simiar), thickness to suit specification. By Others.
11
SFS Substrate - profile size & centres to suit loadings. By Others.
12
V.C.L. - if required. By Others.
13
Internal Finish. By Others.
14
Insulation - If required. By Others.
PVC Anti Rattle Clip
Optima FC Carrier ProfileHook Plate
GasketOptional Colour Match Strip
15161718
@A4
Sotech Ltd2 Traynor WayWhitehouse Business ParkPeterleeCounty DurhamSR8 2RU
Title:
Drg No:
Rev:Scale: Checked By:
Date:Drawn By:
DD
Sotech
Tel: 0191 587 2287Fax: 0191 518 0703
www.sotech-optima.co.uk
Optima FC-ACMVertical Movement Joint
FC-ACM-15 08.04.16
1:3 A
32