&l-;;fm 't;r Pc! qct'l CI') (0 I 7f <l?y/ . '6entral 6rganisatloD Jor 1lfi1way 1 'ITfi lWf 1, N AWAB YUSUF ROM) 5\'II1'W W:: 211 001 ALLAIfA8Al) - 2 JI 001 . No. ELCORE / W-l / Sch Works / EL(G) / Pt.I Dated Tuesday, July 01, 2014. Chief Project Managers, Railway Electrification, Ambala, Bhubaneswar, Chennai, Danapur, Gorakhpur, Jabalpur, Jaipur, Kolkatta, Lucknow, New Jalpaigudi, Secunderabad. Sub Schedule of Rates for General Services. of 57 th Ref Item # 308 of "Recommendations 'ESC held at Pune", circulated vide Board's letter no. 2009 I Elect(TRS) I 138 I 2 Pt dated 25 th October, 2011. Reference above Schedule of Rates for General Services have been prepared at CORE with finance vetting and approval of competent authority. A copy of same is enclosed for your use. Soft copy of same will also be available on CORE's website. U 1 II" [ Akkella P ] Dy.CEE [P] for Chief Electrical Engineer COREl Allahabad +91 9794865 314 Copy 1 Director (RE) I Railway Board I New Delhi 2 CSTE I CORE I Allahabad 3 F A&CAO I CORE with hard copy. 4 CEE ( P&D ) I CORE 5 DyCEE I HQ I CORE 6 SrEDPM I CORE I Allahabad with CD containing soft copy - with a request to upload same on CORE's website as discussed. Q "0- \ [ Akkella P Sarma] Dy.CEE [P] A:ldyceepISORlfinal.doc First page of one pages.

Transcript of SOR for General Services for CORE, Allahabadcore.indianrailways.gov.in/works/uploads/files/SOR for...

  • &l-;;fm 't;r Pc! qct'lCI') (0 I 7f

  • SCHEDULES

  • 1

    Schedule:A Modification Of HT Power Line Crossing 11 kV I 33 kV ( to be read along with explanatory notes)

    CPWD Code Rate# Description of items Unit

    unless mentioned otherwise in Rs. 11 kV CABLE LAYING

    1

    2

    3

    4

    5

    6

    2.1

    2.1 .a

    2.2

    2.2.a

    2.3

    2.3.a

    11CBGR120

    I

    Rate analysis

    arrived from CPWD

    Code 2.1 & RE/S&T

    Sch.

    0208

    11CBGR400

    Rate analysis

    arrived from CPWD

    Code 2.2 & RE/S& T

    Sch.

    0208

    11CBGRT120

    Rate analysis

    arrived from CPWD

    Code 2.3 & RE/S& T

    Sch.

    0208

    11kV cable laying upto 120 sqmm in ground Laying of one number PVC insulated and PVC .sheathed / XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size not exceeding 120 sqmm, direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as re~uired . ____ 11kV cable laying upto 120 sqmm in ground in RCC pipe Laying of one number PVC insulated and PVC sheathed / XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size not exceeding 120 sqmm direct in ground including excavation, laying of 150 mm dia RCC pipe and refilling the trench etc. as required. 11 kV Cable laying upto 400 in ground Laying of one number PVC insulated and PVC sheathed / XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. /' 11 kV Cable laying upto 400 in ground In RCC pipe Laying of one number PVC insulated and PVC sheathed / XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including excavation , laying of 150 mm dia RCC pipe and refilling the trench etc. as required .

    11 kVCable laying upto 120 sqmm in same trench Laying of one number additional PVC insulated and PVC sheathed / XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size not exceeding 120 sqmm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required.

    11 kV Cable laying upto 120 in ground in RCC pipe Laying of one number PVC it)sulated and PVC sheathed / XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size not exceeding 120 sqmm direct in ground in the same trench in one tier horizontal formation including excavation , laying of 150mm dia RCC pipe and refilling the trench etc. as required.

    Metre

    Metre

    Metre

    Metre

    Metre

    Metre

    115X

    30eiY

    121~

    313~

    75~

    274H--

    Akkella P Sarma ~ DyCEE(P) I CORE I ALD scedUle~ DyCEE I RE I MS

    V..- V

    ~~ Sr.~~\\~

  • # CPWD Code unless mentioned otherwise

    Description of items Unit Rate in Rs.

    7 2.4 11CBGRT400 11 kV Cable laying upto 400 sqmm in same trench Laying of one number additional PVC insulated and PVC sheathed I XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size of exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including excavation I sand cushioning , protective covering and refilling the trench etc. as required.

    Metre

    8 2.4.a Rate analysis 11 kV Cable laying upto 400 sqmm in same trench arrived from CPWD in RCC pipe Code 2.4 & RE/S& T Laying of one number additional PVC insulated and

    5ch. PVC sheathed I XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size of exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including excavation , laying of 150 mm dia RCC pipe and refilling the trench etc. as required.

    11 kV cable Laying up to 400 sqmm in pipe Laying of One number PVC insulated and PVC sheathed I XLPE power cable of grade exceeding 1.1. kV but not exceeding 11 kV of size not exceeding 400

    . sqmm in the eXisting RCC I HUME I STONEWARE / METAL pipe as required .

    Metre

    Metre

    277

    9 2.5

    10 2.5.a Rate analysis 11 kV cable Laying up to 400 sqmm in RCC pipe arrived from CPWD Laying of One number PVC insulated and PVC Code 2.5 & RE/5& T sheathed / XLPE power cable of grade exceeding 1.1.

    5ch. kV but not exceeding 11 kV of size not exceeding 400 0208 sqmm in the existing RCC / HUME / STONEWARE I

    METAL pipe as required .

    Metre

    11 2.6 11CBOD400 11 kV Cable laying upto 400 sqmm in open duct Laying of one number ~ PVC insulated and PVC sheathed I XLPE Power cable of grade exceeding 1.1 kV but not exceeding 11 kV of size not exceeding 400 sqmm in the existing masonry open duct as required .

    Metre

    33 kV CABLE LAYING 12 2.7 33CBGR120 33 kV cable laying upto 120 sqmm in ground

    Laying of one number XLPE power cable of grade exceeding 11 kV but not exceeding 33 kV of size not exceeding 120 sqmm direct in ground including excavation I sand cushioning, protective covering and refilling the trench etc. as required.

    Metre

    13 2.7.a Rate analysis arrived from CPWD Code 2.7 & RE/5& T

    5ch. 0208

    33 kV cable lay.ing upto 120 sqmm in Ground in RCC pipe Laying of one number XLPE power cable of grade exceeding 11 kV but not exceeding 33 kV of size not exceeding 120 sqmm direct in ground including excavation I laying of 150 mm dia RCC pipe and refillinq the trench etc. as required.

    Metre

    2

    78~

    X

    280-1

    316;\

    Q.-Akkella P Sarma ~ DyCEE(P) I CORE I ALD Scedule 'A' DyCEE I RE I MS

    vetteo

    ~ 'Sr. A f:" f..

    ~e,

  • --

    # CPWDCode

    unless mentioned otherwise Description of items. Unit

    Rate in Rs.

    14 2.8 33CBGR400 33 kV cable laying upto 400 sqmm in ground Laying of one number XLPE power cable of grade exceeding 11 kV but not exceeding 33 kV of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including excavation. sand cushioning protective covering and refilling the trench etc. as required.

    Metre

    15 2.8.a Rate analysis 33 kV cable laying upto 400 sqmm in ground in arrived from CPWD RCC pipe Code 2.8 & RE/S& T Laying of one number XLPE power cable of grade

    Sch. exceeding 11 kV but not exceeding 33 kV of size 0208 exceeding 120 sqmm but not exceeding 400 sqmm

    direct in ground including excavation laying of 150 mmdia RCC pipe and refilling the trench etc. as required.

    Metre

    16 2.9 33CBGRT120 33 kV cable laying upto 120 sqmm in same trench Laying of one number additional XLPE power cable of grade exceeding 11 kV but not exceeding 33 kV of size not exceeding 120 sqmm direct in ground in the same trench in one tier horizontal formation including excavation sand cushioning protective covering and refilling the trench etc. as required.

    Metre

    17 2.9.a Rate analysis 33 kV cable laying upto 120 sqmm in same trench arrived from CPWD in RCC pipe Code 2.9 & RE/S& T Laying of one number XLPE power cable of grade

    Sch. exceeding 11 kV but not exceeding 33 kV of size not 0208 exceeding 120 sqmm direct in ground in the same

    trench in one tier horizontal formation including excavation . laying of 150 mm dia RCC pipes and refillinQ the trench etc.as required.

    Metre

    18 2.10 33CBGRT400 33 kV cable laying upto 400 sqmm in same trench Laying of one number additional XLPEpower cable of grade exceeding 11 kV but not exceeding 33 kV of size of exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including excavation . sand cushioning protective covering and refilling the trench etc. as required.

    Metre 81

    19 2.10.a Rate analysis 33 kV cable laying upto 400 sqmm in same trench arrived from CPWD in RCC pipe

    Code 2.10 & Laying of one number additional XLPE power cable of RE/S& T Sch. grade exceeding 11 kV but not exceeding 33 kV of size

    0208 of exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including excavation I laying of 150 mm dia RCC pipe and refilling the trench etc. as required.

    Metre

    3

    130W

    321~

    277 --r-

    ~

    280-r

    Akkella P Sarma ~ DyCEE ; :Ea~;rsDyCEE(P) I CORE I ALD Scedule 'A'

  • 4

    ~

    X

    ~

    ~

    ~

    X

    ~

    ~ DyCEE I RE I MS

    ,

    # CPWD Code Description of items.unless mentioned otherwise

    20 2.11 33CBPIP400 33 kV cable laying upto 400 sqmm in pipe Laying of one number XLPE power cable of grade exceeding 11 kV but not exceeding 33 kV of size but not exceeding 400 sqmm in the existing RCC / HUME / STONEWARE / METAL pipe as required.

    21 2.12 33CBBOD400 33 kV cable laying upto 400 sqmm in open duct Laying of one number XLPE power cable of grade exceeding 11 kV but not exceeding 33 kV of size but not exceeding 400 sqmm in the existing masonry open duct as r~uired.

    22 2.13 EXCROCK Hard rock excavation Excavation of the trench in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meters.

    23 3.2 CBRMCC Cable route indicator (Cement Concrete type) Supplying and making cable route marker with cement concrete 1 :2:4 ( 1 Cement: 2 Coarse Sand: 4 graded stone aggregate 20mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required.

    24 3.3 CBRMGI Cable route indicator (G.I type) Supplying and making cable route marker with 10 cm x 10 cm 5 mm thick G.I plate with inscription there on , bolted, welded to 35 mm 35 mm x 6 mm angle iron , 60 cm long and fixing the same in ground as required

    11 kV HEAT SHRINKABLE XLPE CABLE JOINTING 25 5.4 11 HXLlJ

    5.4.1. 5.4.2. 5.4.3. 5.4.4

    5.4.4.a 26 5.5 11HXLOJ

    5.5.1 5.5.2 5.5.3 5.5.4

    'f) 5.5.4.a IdA.. ..61'- 1>. Akkella P Sarma

    DyCEE(P) I CORE I ALD

    11 kV heat shrinkable indoor cable jointing Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 crore , XLPE Aluminum conductor cable of 11 kV grade as required.

    70 sqmm 120 sqmm 240 sqmm 300 sqmm 400 sqmm CJtoJ ?f-i;re.,r-!>')~o~JC.fWj),hQ.VJtR..J..- \o:.,Q. .., 11 kV heat shrrnk'ab~e Outdoor XLPE cable jointing Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following $ize of 3 crore , XLPE Aluminum conductor cable of 11 kV grade as required.

    70 sqmm 120 sqmm 240 sqmm 300 sqmm 400 sqmm I~rn.o l'Q.dT] a,Y-K ~ j >'l J, H.)( 1.-0 )

    Unit Rate in Rs.

    Metre 37 ~ /'

    each

    Metre 31 ~

    Cum 415 /

    Each 113 /

    Each 157 ~/

    each 2500 ~ each 2970 each 3390 each 3390

    3390

    each 3820 each 4180 }each 4470 each 4470 each 4470 H--

  • 5

    # CPWD Code Description of itemsunless mentioned otherwise

    27 5.6 11 HXLSJ 11 kV heat shrinkable Straight Through cable jointing Supplying and making straight through cable jointing kit complete with all accessories including ferrules suitable for following size of 3 crore, XLPE Aluminum conductor cable of 11 kV grade as required.

    5.6.1 70 sqmm 5.6.2 120 sqmm 5.6.3 240 sqmm 5.6.4 300 sqmm

    5.6.4.a 400 sq mm 1.:SaY>\s:L Tel't"W'"./.:.. ~ i YI l.}.e,.,., VI 0 . 2- S-..) 33 kV HEAT SHRINKABLE XLPE CABLE JOINTING

    28 5.14 33HXLlJ

    5.14.1 5.14.2 5.14.3 5.14.4

    5.14.4.a 29 5.15 33HXLOJ

    5.15.1 5.15.2 5.15.3 5.15.4

    5.15.4.a 30 5.16 33 HXLSJ

    5.16.1 5.16.2 5.16.3 5.16.4

    5.16.4.a STEEL TUBULAR POLE & STRUT

    33 kV heat shrinkable Indoor XLPE cable Jointing Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 crore, XLPE Aluminum conductor cable of 33 kV grade as required.

    70 sqmm 120 sqmm 240 sqmm 300 sqmm T ~te.. Yle>r ~ve.n ~ t1--Wl.. ;~ ~vQ.... 400 sqmm t.fc=,k.rm fNL ~re dj., 240 .s~",,,,,, . 33 kV heat shrinkable outdoor XLPE cable Jointing Supplying and making outdoor cable end termination

    . with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 crore, XPLE Aluminum conductor cable of 33 kV grade as required.

    70 sqmm 120 sqmm 240 sqmm 300 sqmm r

  • # CPWD Code

    unless mentioned otherwise Description of items. Unit

    Rate in Rs.

    31 6.6 ERSPCC10 IErection of steel pole or Steel Rail pole upto 10m in C.C Erectiobn of steel pole or steel rail pole of length exceeding 8 metres but not exceeding 10 metres in cement concrete 1:3:6 ( 1 Cement: 3 Coarse Sand: 6 Graded Stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc.as required.

    Each

    32 6.7 ERSPCC12 Erection of steel pole or Steel Rail pole upto 12 m in C.C Erectiobn of steel pole or steel rail pole of length exceeding 10 metres but not exceeding 12 metres in cement concrete 1:3:6 ( 1 Cement: 3 Coarse Sand: 6 Graded Stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.

    Each 1569

    STRUT 33 6.10 ERSPSCC Erection of Steel pole or Rail pole strut in CC

    Erection of steel tubular pole strut or Rail pole strut in Cement Concrete 1:3:6 ( 1 Cement: 3 Coarse Sand: 6 Graded Stone aggregate 40 mm nominal size) foundation including excavation and re filling and secured with holding clamps . bolts . nuts etc. as required.

    each

    STAY 34 8.1 11STY S/E 11 kV Stay set

    Supplying and erection of galvanized stay set for 11 kV over head lines complete with 19/20 mm dia x 1.8 metres long stay rod anchor plate of size 45 cm x 45 cm x7.5 mm thick. thimble. stay clamps. turn buckle(20mm x 600 mm) . 7/4.00 mm dia G.I. stay wire and 11 kV stain insulator etc. in cement concrete 1:3:6 ( 1 Cement: 3 Coarse Sand: 6 Graded Stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.

    Set

    35 8.7 11DPCR75 11 kV double pole 75 mm channel iron cross arm Supplying of two lengths of channel iron 75mm x 40mm x 5.70 kg/mtr double pole cross arm for three wire 11 kV overhead line conductors complete with through bolts and nuts for clamping to the poles 50mm x 6mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together including drilling holes for insulators pinslfittings. bolts and nuts etc. and painting with primer and finish paint as required.

    set

    6

    1343~

    ---r

    1652X

    2120~

    1947rr

    ~ Akkella P Sarma DyCEE(P) I CORE I ALD DyCEE I RE I MS

  • 7

    259~W

    216/\

    282~

    905~

    S020~

    # CPWD Code unless mentioned otherwise

    Description of items Unit Rate in Rs.

    36 8.8 11CBR50 S/E 11 kV cross bracing Supplying and erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of SO mm x SOmm x 6 mm angle iron to form a rectangle of minimum size 1400 mm width x 2S00 mm height, complete with SO mm x 6 mm MS flat iron clamps , bolts and nuts including drilling holes etc. and painting with primer and finish painting as required.

    Set

    37

    ~__,

    8.9

    +-____ ~

    11 133 DPCRER

    ______ ~~____~

    11 122/33 kV double pole cross arm erection Erection of double pole 3 wire cross arm for 11 k~V~~=2~k~V~/3=3~k~V~0~v~e~rh~e~a~d~l~in~e~s~a~s~re~!Q~lu~ir~e~d~.________~

    /Sen ~--~----~------~

    38 8.10 11 PI S/E 11 kV pin insulators Supplying and erection of 11 kV pin insulator complete with large steel head G.!. Pin, nuts, washers etc. as required.

    Set

    39 8.11. 11 DI S/E 11 kV disc insulator , Supplying and erection of 11 kV disc insulator for 11 kV over head lines with galvanized insulator fittings , ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required.

    Set

    40 8.12 11DII PIER 11 kV disc/pin insulator erection ~r~on of disc/pin insulator for 11 kV over head lines as required

    Set

    41 8.13 11LA S/E 11 kV lightning arrestor Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9kV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement, G.!. bolts ., nuts washers etc. as required.

    Set

    42 8.21 33STY S/E 33 kava Stay set Supplying and erection of galvanized stay set for 33 kV over head lines complete with 19/20 mm dia x 1.8 metres long stay, rod, anchor plate of size 45 cm x 4S cm x7.5 mm thick, thimble, stay clamps, turn buckle (20mm x 600 mm) , 7/4.00 mm dia G.!. stay wire and 33 kV stain insulator etc. in cement concrete 1 :3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling as required.

    Set

    43 8.28 33DPCR100 33 kV double pole cross arm Supplying of two lengths of channel iron 100mm x SOmm x 9.S6 kg/mtr double pole cross arm for three wire 33 kV overhead line conductor complete with through bolts and nuts for clamping to the poles , SOmm x 6mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together , including drilling holes for insulators pinslfittings , bolts and nuts etc. and painting with primer and finish paint as required.

    Set

    1\ b

    2610~

    Akkella P Sarma ~ DyCEE(P) I CORE I ALD scedUI~............... DyCEE I RE I MS

    Vett~ :I. ~.

    ,. i"" , Sr. AfA ~~ \0"\

  • 8

    I

    ,

    Akkella P Sarma ~ DyCEE(P) I CORE I ALD Scodulo'A' / DyCEE I RE I MS

    # CPWD Code unless mentioned otherwise

    44 8.29 33CBR65

    45 8.30 33PI

    46 8.31 3301

    47 8.32 33LA

    DANGER BOARDS 48 2.72. DANPLHV

    (Part.1 Internal)

    EARTHING 49 RE.OHE Sch.17.a

    50 RE.OHE Sch.17.E 51 3.10 EAR6GGIWR

    1

    52 3.11 EARG;J~5X5

    ANTI CLIMBING DIVICE 53 RE OHE Sch.30(b)(ii)

    CONDUCTORS 54 7.21 ERCON3.00

    ~ h'" --

    Description of items

    S/E 33 kV cross bracing Supplying and erection of a set of cross bracing frame work for 33 kV over head line double pole structure having four members fabricated out of 65 mm x65mm x 6 mm angle iron to form a rectangle of minimum size 2400 mm width x 2800 mm height I complete with 50 mm x 6 mm MS flat iron clamps I bolts and nuts including drilling holes etc. and painting with primer and finish painting with primer and finish paint as required . S/E 33 kV pin insulators Supplying and erection of 33 kV pin insulator complete with large steel head G.I. Pin nuts I washers etc. asI required. S/E 33 kV disc Insulator Supplying and erection of 11 kV disc insulator for 33 kV over head lines with galvanized insulator ~ttings I ball and socket type and complete with galvanized strain clamps I bolts I nuts I washers etc. as required.

    S/E 33 kV lightning arrestor Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire I 33 kV overhead lines with rated voltage 30 kV (rms) with a nominal discharge current rating of 10 KA ( station class ) and complete with galvanized clamping arrangement I G.I. bolts I nuts washers etc. asI required.

    P/F H.v danger plate: Providing and fixing H.T. danger notice plate of 250 mm x 200 mm made of mid steel at least 2 mmI I thick and vitreous enameled white on both sides II and with inscription in single red color on front side as required

    G.I. earth pipe electrode Supply and erection of single earth electrode. Supply and erection of 8 SWG GI wire for earthing S/L of 6 SWG GI wire Supply and laying of 6 SWGGI wire at 0.50 metre below the ground level for conductor earth electrode including soldering etc; as required -S/L of 25mm x 5mm G.J. earth strip In ground Supply and laying of 25mm x 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode I including soldering etc. as required.

    Supply and erection of Anticlimping device.

    Erection of ACSR conductor upto 7/3.00 mm Erection of ACSR conductor of 7/2.11 mm to 7/3.00 diameter including binding etc. as required.

    Unit Rate in Rs.

    Set 4080 rr

    Set 839 {-,

    Set 2658 ~

    Set 35800 ~

    each 75 t'~

    each 1191 V Metre 11 l/

    Metre 16 ~

    Metre 45 1--each 1448 /

    Kg 34 ;,r

    \lett" cri'V.~.\~:~..~

  • 9

    ./

    # CPWDCode unless mentioned otherwise

    55 7.22 ERCON3.35

    56 7.23 ERCONAA3.1

    57 7.24 ERCONAA3.4

    58 7.25 ER8GIWR

    59 7.40 POLPIP80

    60 7.41 POLPIP100

    61 7.42 DISOHL

    62 7.43 DISPOLBB

    63 7.44 DISPOLCC

    64 DetaeTED 65 oetE~Jl:D 66

    [j~t~D

    Description of items Unit Rate In Rs.

    Erection of ACSR conductor upto 7/3.35 inm Erection of ACSR ~ductor of 7/3.35 diameter and Kg 45 ~ above including binding(etc. a.s reQu>ed. . Erection of AA conductor upto 7/3.10 mm Erction of All aluminum conductor of 7n.96 mm to Kg 457/3.10mm dia meter including binding etc. as Krequired. , Erection of AA conductor upto 7/3.40 mm Erection of All aluminum conductor of 7/3.40mm dia Kg 35 ~ meter and above including binding etc. as required. '" Erection of 8 SWG GI Wire Erection of G.I. wire No: 8SWG including binding etc. Kg 7~ as required. S/F80mm cable protection pipe on pole Supplying and fixing of GI pipe of 80 mm dia " each 884 l'(nominal) 3 metres length along the pole for protection "" of under ground cable as required. "

    S/F100mm cable protection pipe on pole Supplying and fixing of GI pipe of 100 mm dia , each 1234 W(nominal) 3 metres length along the pole for protection of under ground cable as required. Dismantling OH lines Dismantling of overhead lines

    . . ofcompnsmg kg 15 H'copper/aluminum over head conductor, GI wire, cross

    arms Insulators etc. as required. Dismantling pole in BB Dismantling of pole/streetlig ht standard/strut each 341 Wembedded in brick ballast foundation e~c. as required. Dismantling pole in CC Dismantling of pole/streetlight standard/strut each 454 W"embedded in Cement Concrete foundation etc. as required.

    ~S~pply , ere~!1:rT3t:J of 33 kV/400A I set 46750Air break SWlt S~pply, ere~f)et.'Ei T1:Dof 11 kV/200A, Air break SWlt

    set 17680 X Horizontal bor:.DS,~~E Supply and layi Ip 50 mm dia by Metre 3038 (horizontal direct dirllingjHDD) method .

    .~ Akkella P Sarma

    DyCEE(P) , CORE' ALD Scedule 'A~ . DyCEE '~RE. ' MS

    V~~~. 11'>10 {, If,b02{j, eJ;J a(

    i

  • 67

    68

    1

    Schedule:B Modification Of L T Power Line Crossing ( to be read along with explanatory notes)

    #

    69

    70

    71

    72

    73

    ,..,.

    1.1

    1.2

    1.3

    1.4

    1.5

    1.6

    1.7

    CPWD Code Description of items Unit

    unless mentioned otherwise

    MVCBGR25 MV Cable laying upto 25 sqmm in ground Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size not exceeding 25 sqmm direct in ground including

    Metre

    excavation, sand cushioning protective covering and refilling the trench etc as required.

    MVCBGR120- MV Cable laying upto 120 sqmm in ground Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm Metre direct in ground including excavation, sand cushioning protective covering and refilling the trench etc as required.

    MVCBGR400 MV Cable laying upto 400 sqmm In ground ' Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size exceeding 120sqmm but not exceeding 400 sqmm Metre direct in ground including excavation, sand cushioning protective covering and refilling the trench etc as required.

    MVCBGRT25 MV Cable laying upto 25 sqmm in the same trench Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm direct in ground in the same Metre trench in tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc as required.

    MVCBGRT120 MV Cable laying upto 120 sqmm in the same trench Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground in the same trenching one tier

    Metre

    horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc as required.

    MVCBGRT400 MV Cable laying up to 400 sqmm in the same trench Laying of one number additional PVC insulated and PVC sheathed I XLPI;: power cable of 1.1 kV grade of size exceeding 120 sqmm but not exceeding 400 Metre sqmm direct in ground in the same trenching one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc as required .

    MVCBPIP25 MV Cable laying up to 25 sqmm in pipe Laying of one number of PVC insulated and PVC sheathed I XLPE power cable 1.1 kV grade of size not Metre exceeding 25 sqmmin the existing RCC I HUME I STONEWARE I METAL pipe as required.

    Rate

    85, !....... ~

    60~

    15 rr Akkella P Sarma ~ DyCEE(P) I CORE I ALD DyCEE I RE I MS

    j?~,,~

    Sr. AfA ~::=~\~'\

  • 2

    # CPWD Code unless mentioned otherwise

    Description of items . Unit Rate

    74 1.8 MVCBPIP400 MV Cable laying up to 400 sqmm in pipe Laying of one number of PVC insulated and PVC sheathed / XLPE power cable 1.1 kV grade of size exceeding 25 sqmm but not exceeding 400 sqmm the existing HUME / STONEWARE / METAL pipe as

    Metre 21 (. rr

    required.

    75 1.9 MVCBOD25 MV Cable laying up to 25 sqmm in open duct Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1.kV grade of size not exceeding 25 sqmm in the masonry open duct as

    Metre 12 X required.

    76 1.10 MVCBOD400 MV Cable laying up to 400 sqmm in open duct Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1.kV grade of size Metre 17 ~ exceeding 25 sqmm but not exceeding 400 sqmm in the masonry C>Qen duct as required. ,

    77 1.11 MVCBSUR25 MV Cable laying up to 25 sqmm on surface Laying and fixing of one number PVC insulated and PVC sheathed I XLPE Aluminum Conductor cable of 1.1.kV grade of size not exceeding 25 sqmm on

    Metre 3}W surface as r~quired .

    78 1.12 MVCBSUR120 MV Cable laying up to 120 sqmm on surface Laying and fixing of one number PVC insulated and PVC sheathed I XLPE Aluminum Conductor cable of 1.1.kV grade of size exceeding 25 sqmm but not

    Metre 59 W . exceeding 120 sqmm on surface as r~uired.

    79 1.13 MVCBSUR400 MV Cable laying up to 400 sqmm In surface Laying and fixing of one number PVC insulat~d and PVC sheathed I XLPE Aluminum Conductor cable of Metre 61 ~ 1.1.kV grade of size exceeding 120 sqmm but not

    I

    exceeding 400 sqmm on surface as required. 80 1.21 MVCBGR25W MV Cable laying up to 25 sqmm In ground without

    sand and cover Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1. kV grade of size not exceeding 25 sqmm direct in ground including

    Metre 49 rr excavation and refilling the trench etc as required but excluding sand cushioning and protective covering .

    81 1.21.a Rate analysis MV Cable laying up to 25 sqmm in ground in 150 arrived from CPWD mm dia RCC pipe

    Code 1.21 & Laying of one number PVC insulated and PVC RE/S&T Sch.

    0208 sheathed I XLPE power cable of 1.1 kV grade of size not exceeding 25 sqmm direct in 150 mm dia RCC

    Metre 276 X pipe including excavation, sand cushioning protective covering and refilling the trench etc as required but excludinq sand cushioninq and protective coverin..Q.

    Akkella P Sarma r::r-DyCEE(P) I CORE I ALD Schedule'S' .n II ~. DyCEE I RE I MS

    yen 6flVV

    ~ ..M( Sr. AF/\ ~--~7.

  • 3

    # CPWD Code unless mentioned otherwise

    Description of items ' Unit Rate

    82 1.22 MVCBGR120W MV Cable laying up to 120 sqmm in ground without sand and cover Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm

    Metre

    direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering.

    83 1.22.a Rate analysis MV Cable laying up to 120 sqmm in ground in 150 arrived from CPWD mm dia RCC pipe

    Code 1.22 & Laying of one number PVC insulated and PVC RE/5& T 5ch.

    0208 sheathed / XLPE power cable of 1.1 kV grade of size exceeding 120sqmm but not exceeding 400 sqmm

    Metre 282 [;(

    direct in 150 mm dia RCC pipe including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering.

    84 1.23 MVCBGR400W MV Cable laying up to 400 sqmm in grouno'without sand and cover Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1. kV grade of size exceeding 120 sqmm but not exceeding 400 sqmm

    Metre

    direct in ground inqluding excavation and refilling the trench etc as required but excluding sand cushioning and protective coverinQ.

    85 1.23.a Rate analysis MV Cable laying up to 400 sqmm in ground in 150 arrived from CPWD dia RCC pipe

    Code 1.23 & Laying of one number PVC insulated and PVC - RElS& T Sch.

    0208 sheathed / XLPE power cable of 1.1 kV grade ,of size exceeding 25 sqmm but not exceeding 120 sqmm

    Metre 287~ direct in 150 mm dia RCC pipe including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering.

    86 1.24 MVCBGRT25W MV Cable laying up to 25 sqmm In the same trench without sand and cover Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size not exceeding 25 sqmm direct in ground in the same trench in one tier horizontal formation including

    Metre 26X ./ \

    excavation, and refilling the trench etc as required but excluding sand cushioning, protective covering.

    87 1.25 MVCBGRT120W MV Cable laying up to 120 sqmm in the same trench without sand and cover Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground in the same trench in one tier

    Metre 291 ~/rn horizontal formation including excavation, and refilling the trench etc as required but excluding sand cushioninQ, protective covering ..

    Akkella P Sarma ~ DyCEE(P) I CORE I ALD SChedUle'B~ DyCEE I RE I MS

    Vett.~

    '\ .1fIIi - .

    Sr. ..FA ~o1

  • # CPWD Code unless mentioned otherwise

    88 1.26 MVCBGRT400W

    89 3.2 CBRMCC

    90 3.3 CBRMGI

    BRASS COMPRESSION GLAND 91 4.1 MVET

    4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7 4.1.8 4.1.9 4.1.10 4.1.11 4.1.12 4.1.20 4.1.21 4.1.22 4.1.23 4.1.24 4.1.25 4.1.26 4.1.27 4.1.28 4.1.29 4.1.30

    f\4.1.31

    Description of items Unit Rate

    MV Cable laying up to 400 sqmm in the same trench without sand and cover Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size exceeding 120 sqmm but not exceeding 400 Metre 32 f"sqmm direct in ground in the same trench in one tier

    ('

    horizontal formation including excavation, and refilling the trench etc as required but excluding sand cushioninQ, protective coverinQ. Cable route indicator CC type Supplying and making cable route marker with cement concrete 1 :2:4 ( 1 Cement: 2 Coarse Sand: 4 graded stone aggregate 20mm nominal size) of size 60 cm x Each 113 f60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required. Cable route i::tt~Cm; GI type ,. Supplying and . a I cable route marker with 10 em x 10 cm 5 mm thick G.I plate with inscription there on, Each 157 .vbolted. welded to 35 mm 35 mm x 6 mm angle iron, 60 , cm long and fixing the same in ground as required.

    LV I MV Cable end termination Supplying and making end termination with brass compression gland and aluminum lugs for following I size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1. kV grade as required.

    t2 x 6 sqmm Each 69 2x10sqmm Each 76 2 x 16 sqmm Each 101 ~2 x25 sqmm Each 119 2 x 35 sqmm Each 121 ~2 x 50 sqmm - Each 140 3 x 10 sqmm Each 102

    ~3x16sqmm Each 120 3 x25 sqmm Each 128 ~3 x 35 sqmm Each 125 3 x 50 sqmm Each 125-t3 x 70 sqmm Each 169 3 1/2 x 25 sqmm Each 106 ~ 3.1/2 x 35 sqmm Each 137 3.1/2 x 50 sqmm - Each 146 X' 3.1/2 x 70 sqmm Each 168 X 3.1/2 x 95 sqmm Each 197 X 3.1/2 x 120 sqmm Each 199 ~ 3.1/2 x 150 sqmm Each 278

    ~3.1/2 x 185 sqmm Each 319 3.1/2 x 225 sqmm Each 328 f3.1/2 x 240 sqmm Each 381 3.1/2 x 300 sqmm Each 508 ~ 3.1/2 x 400 sqmm Each 508 %

    ~ .... -A !Ill"" 'VI

    Akkella P Sarma

    DyCEE(P) I CORE I ALD DyCEE I RE I MS:;:r/ ~

    ~ ,.-' Sr. ,.'A ~I~~

  • 5

    X W ~:

    ~ -1"

    t

    ~

    ~

    ~

    ~

    ~

    ~

    ~ ~

    ,

    ~

    ~

    ~.

    /. !.!L -"I'>. ~ ... 'V,.I- ~-

    # CPWD Code unless mentioned otherwise

    4.1.32 4.1.33 4.1.34 4.1.35 4.1.36

    92 4.2 MVOJ

    4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.2.6 4.2.7 4.2.8 4.2.9

    4.2.17 4.2.18 4.2.19 4.2.20 4.2.21 4.2.22 4.2.23 4.2.24 4.2.25 4.2.26 4.2.27 4.2.28 4.2.29 4.2.30 4.2.31 4.2.32

    93 4.3 MVSJ

    4.3.1 4.3.2 4.3.3 4.3.4 4.3.5 4.3.6 4.3.7 4.3.8 4.3.9 4.3.17

    ) 4.3.18

    Description of items .

    4 X 10 sqmm 4x16sqmm 4x25sqmm 4 x 35 sqmm 4 x 50 sqmm LV/MVout door Cable jointing Supplying and making out door end termination with cast resin compound including aluminum lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required.

    2x16sqmm 2x25sqmm 2 x 35 sqmm 2 x 50 sqmm 3x16sqmm 3 x25 sqmm 3 x 35 sqmm 3 x 50 sqmm 3 x 70 sqmm 3.1/2 X 25 sgmm 3.1/2 x 35 sgmm 3.1/2 x 50 sqmm 3.1/2 x 70 sqmm 3.1/2 x 95 sqmm 3.1/2 x 120 sqmm 3.1/2 x 150 sqmm 3.1/2 x 185 sqmm 3.1/2 x 225 sqmm 3.1/2 x 240 sqmm 3.1/2 x 300 sqmm 3.1/2 x 400 sqmm 4x16sqmm 4 x25 sqmm ~

    4 x 35 sqmm 4 x 50 sqmm LV/MV straight through Cable jointing Supplying and making straight through jOint with cast resin compound including ferrules and other jointing materials for the following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required. 2 x 16 sqmm 2 x 25 sqmm 2 x 35 sqmm 2x50sqmm 3 x 16 sqmm 3 x 25 sqmm 3 x 35 sqmm 3 x 50 sqmm 3 x 70 sqmm 3.1/2 X 25 sqmm 3.1/2 x 35 sqmm

    Unit Rate

    Each 104 Each 196 Each 137 Each 157 Each 183

    Each 284 Each 294 Each 294 Each 366 -1' Each 294 Each 294 Each 325 Each 357 fr Each 357 Each 294 Each 357 Each 408 Each 438 Each 466 Each 466 Each 566 Each 615 Each 733 Each 733 Each 771 Each 771 Each 335-Each 335-Each 408-Each 408

    Each 582 f\" Each 689 ~ Each 619 Each 670 Each 58~W Each 582 Each 582 Each 670 Each 786-Each 611.~Each 670

    Akkella P Sarma .~_.,....~~_r: 1 DyCEE(P) I CORE I ALD DyCEE I RE I MS

    Sr. A.'A ~1 04

  • 6

    . f

    # CPWD Code unless mentioned otherwise

    4.3.19 4.3.20 4.3.21 4.3.22 4.3.23 4.3.24 4.3.25 4.3.26 4.3.27 4.3.28 4.3.29 4.3.30 4.3.31 4.3.32

    31 of 6.6 ERSPCC10 Sch.

    A

    32 of 6.7 ERSPCC12 Sch.

    A

    STRUT 33 of 6.10 ERSPSCC Sch.

    A

    94 7.1 STYTB4.00

    Description of items Unit Rate

    3.1/2 X 50 sqmm Each 773 ~. ~

    3.1/2 x 70 sqmm Each 840 r3.1/2 x 95 sgmm Each 885 3.1/2 x 120 sqmm Each 1220

    ~3.1/2 x 150 sgmrri Each 1270 3.1/2 x 185 sgmm Each 1420 3.1/2 x 225 sqmm Each 1590 ~ 3.1/2 x 240 sqmm Each 1690 ~3.1/2 x 300 sqmm Each 1960 3.1/2 x 400 sqmm Each 1960 ~4x16sgmm Each 597 4 x25 ~mm Each 670 ~ 4 x 35 sqmm Each 714 4 x 50 sqmm Each 773. ~

    Erection of steel pole or Steel Rail pole upto 10m inCC Erection of steel pole or steel rail pole 'Of length exceeding 8 metres but not exceeding 10 metres in Each 1343 {cement concrete 1 :3:6 ( 1 cement: 3 coarse sand: 6 ,/ graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Erection of steel pole or Steel Rail pole upto 12 m in CC Erection of steel pole or steel rail pole of length exceeding 10 metres but not exceeding 12 metres in Each 1569 rcement concrete 1 :3:6 ( 1 cement: 3 coarse sand: 6 ,../ graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as reguired.

    Erection of Steel pole or Rail pole strut in CC Erection of steel tubular pole or Rail pole strut in Cement Concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 40mrym nominal size) each 1652 Kfoundation including excavation and re filling and

    /

    secured with holding clamps, bolts, nuts etc. as required.

    7 14.00 mm Stay set with turn buckle Supply and erection of stay set complete ( galvanized) with 19 / 20 mm dia x 1.8 metres long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm, thimble, stay clamps, turn buckle (20mm x 6~), 7 14.00 mm dia each 2060 GI stay wire and strain insulator etc. in cement / concrete 1 :3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.

    Akkella P Sarma ~ DyCEE(P) I CORE I ALD DyCEE I RE I MS

    J.-r ~"

  • # CPWD Code unless mentioned otherwise

    Description of items Unit Rate

    95 7.2 STYTB3.15 7 I 3.15 mm Stay set with turn buckle Supply and erection of stay set complete ( galvanized) with 19 / 20 m m dia x 1.8 metres long stay rod , anchor plate of size 45 cm x 45 cm x 7.5 mm, thimble stay clamps turn buckle ( 20mm x 6o.~\ 7 / 3.15 mm dia GI stay wire and strain insulator etc. in cement concrete 1 :3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required .

    ....,..,.

    each 1924

    "" y

    96 7.10 MVCR2WSR75 LV I MV 2 wirejmm channel iron cross arm Supplying of channel iron 75 mm x 40mm x 7.14 kg per metre crossarm for 2 wire over head line complete with clamps, bolts and nuts etc including drilling of holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.

    set 272 ",V

    97 7.11 MVCR4WSR75 LV I MV 4 wir~m channel iron cross arm Supplying of channel iron 75 mm x 40mm x 1.14 kg per metre cross arm for 4 wire over head line complete with clamps, bolts and nuts etc including drilling of holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.

    set 477

    98 7.12 EMVCR Erection of channel iron cross arm Erection of channel iron cross arm on RCC / PCC / Steel tubular /rail pole etc as required.

    set

    99 7.16 SI75 x 90 Supply and erection of 75 mm x 90 mm shackle insulator Supply and erection of 75 mm x 90 mm s,hackle insulator with GI bolt, nuts and straps etc. as required.

    set I

    100 7.17 SI100 x 110 Supply and erection of 100 mm x 110 mm shackle insulator Supply and erection of 100 mm x 110 mm shackle insulator with GI bolt, nuts and straps etc as required.

    set 122

    101 7.18 PI100x65 Supply and erection of pin insulator 65mm Supply and erection of 100 mm x 65 mm pin insulator complete with G.I spindle and nuts etc as required.

    set

    102 7.19 PI100 x 80 Supply and erection of pin insulator 80mm Supply and erection of 100 mm x 80 mm pin insulator complete with G.I spindle and nuts etc as required.

    /pil?

    set

    103 7.20 ERSIPI Erection of LV/MV shackl~~nsulator etc as required. set

    54 of Sch.

    A

    7.21 ERCON3.00 Erection of ACSR conductor upto 7 I 3.00 mm Erection of ACSR conductor of 7 / 2.11 mm to 7 / 3.00 dia including binding etc as required.

    I"rt1Y\ Kg

    55 of Sch.

    A

    7.22

    l'.

    ERCON3.35 Erection ofACSR conductor upto 7 I 3.35 mm Erection of ACSR conductor of 7 / 3.37-,""dia including binding etc as required.

    Kg 45

    7

    ...~

    51 '" ~

    102 rr .. ~

    47 rr '< (

    5t rr 14 -1 34 r

    1/ W A....- .... '-';-

    Akkella P Sarma ~ DyCEE(P) , CORE' ALD DyCEE " ::~~~ \

    +.:~~. Sr. AFA ~I t

  • 8

    # CPWD Code unless mentioned otherwise

    Description of items . Unit Rate

    56 of Sch.

    A

    7.23 ERCONAA3.1 Erection of AA conductor upto 7/3.10 mm Erection of All aluminum conductor of 7 / 1.96 mm to 7 / 3.1 Omm dia including binding etc as required.

    Kg 45

    57 of Sch.

    A

    7.24 ERCONAA3.4 Erection of AA conductor upto 7/3.40 mm Erection of All aluminum conductor of 7 / 3.40mm dia including binding etc as required.

    Kg .,

    58 of Sch.

    A

    7.25 ER8GIWR Erection of 8 SWG GI wire Erection of GI wire No. 8SWG including binding etc. as required.

    Kg ./

    104 7.26 ERHEXGD Erection of hexagonal type guard as required. each 105 7.34 STLBR20

    "'-br -h'rr Street Light Bracket 20 mm dia SUjplying and fixing of 20 mm dia G.1. pipe for street ligh!-\bracket including bending to shape, 40 mm x 3 mm flat iron clamps and wiring with 1.5 sqmm WP / PVC wire and painting the flat iron with primer and finish paint etc. as required. "

    each

    106 7.36 STLBR32 Street Light Bracket 32 mm dia Supply and fixing of 32 mm dia x 2.00 metres long G.1. Pipe (medium class ) bracket for mounting of fluorescentlHPMV / HPSV street light fitting on pole including bending the pipe to the required shape , 40 mm x 3 mm flat iron clamps and wiring with 1.5. sqmm WP / PVC wire and painting the flat iron with primer and finish paint etc as required.

    each

    107 7.39 POLPIP50 S / F 50 mm cable protection pipe on pole Supplying and fixing of GI pipe of 50 mm dia (nominal), 3 metres length along the pole for protection of under I ground cable as required.

    each

    108 7.40 POLPIP80 S / F 80mm cable protection pipe on pole Supplying and fixing of GI pipe of 80 mm dia (nominal) 3 metres length along the pole for protection of under ground cable as required.

    each

    109 7.41 POLPIP100 S / F 100mm cable protection pipe on pole Supplying and fixing of GI pipe of 100 mm dia (nominal) 3 metres length along the pole for protection of under ground cable as required.

    each

    61 of Sch.

    A

    7.42 DISOHL Dismantling OH lines Dismantling of overhead lines comprising of copper / aluminum over head conductor, GI wire, cross arms, insulators etc as required.

    kg 15,.

    62 of Sch.

    A

    7.43 DISPOLBB Dismantling pole in BB Dismantling of pole / streetlight standard / strut embedded in brick ballast foundation etc as required.

    each .. 63 of Sch.

    A

    7.44 DISPOLCC Dismantling pole in CC Dismantling of pole / streetlight standard / strut embedded in Cement Concrete foundation etc as required.

    each 454

    ~

    35 v

    7 r 37 -r

    39~y

    403 K

    603 rr/

    884 rr 1234 ~/

    rr /

    341 1

    ~ Akkella P Sarma DyCEE(P) I CORE I ALD .Ch.dUI.~ DyCEE I RE I MS

    V~t~:

    I.~~

  • --

    # CPWDCode Description of itemsunless mentioned otherwise

    Unit " Rate

    110 2.71 DANPLMV Supply & fixing of MV danger board

    ~ Providing and fixing MV danger notice plate of 200mm \Y).fe,rn cJ "x 150mm, made of mild steel, at least 2 mm thick, and

    vitreous enameled white on both sides, and with " inscription in single red color on front side as required.

    each 68

    49 of Sch.

    A

    RE.OHE Sch.17.a G.I. Earth Pipe Electrode Supply and erection of single earth electrode. each 1191

    50 of Sch.

    A

    RE.OHE Sch.17.E Supply and erection of 8 SWG GI wire for earthing Metre 11

    51 of 3.10 Sch.

    A

    EAR6GGIWR S'L of6 SWG GI wire Supply and laying of 6 SWG GI wire at 0.50 m~tre below the ground level for conductor earth electrode including soldering etc as required.

    Metre -~

    52 of 3.11 Sch.

    A

    EARGI25x5 S , L of 25mm x 5mm G.I. earth strip In groun'd Supply and laying of 25mm x 5 mm G.I. strip at 0.50 metre below ground as strip earth electrod~, including soldering etc as required.

    Metre 45 -

    111 1.41 ITCFFSUR Fixing of light fittings (IN'rERNAL) Installation, testing and commissioning of pre wired

    fluorescent fitting I compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling I wall, including connection with 1.5 sqmm FR PVC insulated copper conductor, single core cable and earthing etc as required.

    -each

    "0

    43

    112 RE LOA ELCORE / Supply &fixing of loop In 'loop out box T / TSS / Gr.144/592 Supply, erection of loop in loop out MS box made up of

    16 SWG MS sheet of size 300 x 250 x 100 mm. No 600

    Rate analysis Supply & erection of out door kiosk with 100 amp

    DELETED ~~:;;rerection of I E~t'l~' klos uitable size r---~----------

    Rate analysis Supply & erection of out door kiosk with 200 Amp114

    f DELETI~C)~;rerection ofo~~6iS s itable size for fixing switches with 200 Amp bus bar as per specification.

    set

    set

    29206

    30940

    115

    t Rate analysis Supply, erection testing and commissioning of

    main L T distribution panel board DELETEr jSupply, erection te~~ c;;i s ' n of main LT ,a... distribution panel ~rcrcOO~ p oe up of 14

    SWG as per specification.

    No 127126

    116

    i Rate analysis Supply, erection testing and commissioning of sub

    L T distribution panel board DELETE'r ().up~ly, .erection testili9\!koDftl!l!!i~f sub L T

    , L ~istnbutlon panel bO~~Hy~EiWup of 14 SWG as per specification.

    No

    66 of Sch.

    A

    Rate a~~ ET~~ntal boring a'l'4>f'W.si~hUI:L . E/1gIt and laying of 1lUc~miil~m dia by

    , . " horizontal boring (HOD) method. " " ". : ' : .. Metre

    9

    .... f

    16 ~

    .. \'

    X

    .. /

    X

    (

    98566 X

    3038:1

    ... Akkella P Sarma ~ DyCEE(P) I CORE I ALD SChedule~~..//) /' DyCEE I RE I MS

    Veft,r::4.J U410 "0,114," S- t 11 (, ~ - '..!

  • 10

    ,

    I-'

    # CPWD Code unless mentioned otherwise

    Description of items Unit Rate

    117 Df!(ee~o SUPPly,ndE''''' . illings Supply and r . 0fti!ol la.'I :l'ngs 1 x 250 watts metal halide with am .

    No 8525

    118 DEttEnj'EsO Supply & erecti~\!~'ingSSupply and ft f l ings 1 x 250 watts metal halide WI amp,

    No 10973

    Akkella P Sarma ~ DyCEE(P) I CORE I ALD Schedule'B' DyCEE I RE I MS

  • 1

    Schedule:C Power Supply Arrangements For Colour Light Signaling ( to be read along with explanatory notes)

    #

    67 of Sch.B

    68 of Sch.B

    70 of Sch.B

    71 of Sch.B

    73 of Sch.B

    74 of

    Sch.B

    75 of Sch.B

    1.1

    1.2

    1.4

    1.5

    1.7

    1.8

    1.9

    CPWD Code Description of work

    unless mentioned otherwise

    MVCBGR25 MV Cable laying upto 25 sqmm in ground Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1. kV grade of size not exceeding 25 sqmm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    MVCBGR120 MV Cable laying upto 120 sqmm in ground Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1. kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    MVCBGRT25 MV Cable laying upto 25 sqmm in the same trench Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1. kV grade of size not exceeding 25 sqmm direct in ground in the same trench in tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    MVCBGRT120 MV Cable laying upto 120 sqmm in the same trench Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1. kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground in the same trench in ' one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    MVCBPIP25 MV Cable laying upto 25 sqmm in pipe Laying of one number of PVC insulated and PVC sheathed I XLPE power cable 1.1 kV grade of size not exceeding 25 sqmm in the existing RCC I HUME I STONEWARE I METAL pipe as required.

    MCVBPIP400 MV Cable laying upto 400 sqmm in pipe Laying of one number of PVC insulated and PVC sheathed I XLPE power cable 1,1 kV grade of size exceeding 25 sqmm but not exceeding 400 sqmm in the existing RCC I HUME I STONEWARE I METAL I pipe as required.

    MVCBOD25 MV Cable laying up to 25 sqmm in open duct Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 .kV grade of size not exceeding 25 sqmm in the masonry open duct as required.

    Unit

    Metre

    Rate

    85

    Metre 91

    Metre 57

    Metre

    Metre

    Metre 21

    Metre

    ~Akkella P Sarma DyCEE(P) I CORE I ALD Schedule 'C' DyCEE { RE { MS

  • 2

    CPWD Code RateUnitDescription of work# unless mentioned otherwise

    MV Cable laying up to 400 sqmm in open duct

    Sch.B

    76 of 1.10 MVCBOD400

    Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 .kV grade of size 17Metre

    ,/exceeding 25 sqmm but not exceeding 400 sqmm in

    the masonry open duct as required .

    77 of MVCBSUR25 MV Cable laying up to 25 sqmm on surface

    Sch.B

    1.11 Laying and fixing of one number PVC insulated and PVC sheathed I XLPE Aluminum conductor cable of Metre 31 1.1.kV grade of size not exceeding 25 sqmm on x: surface as required .

    78 of MV Cable laying up to 120 sqmm on surface1.12 MVCBSUR120 i

    Laying and fixing of one number PVC insulated and PVC sheathed I XLPE Aluminum Conductor cable of

    Sch.B Metre 59

    >

  • 3

    t

    ,/

    /

    ~

    ..

    # CPWD Code Description of work Unit Rate

    unles~ mentioned otherwise

    86 of 1.24 MVCSGRT25W MV Cable laying upto 25 sqmm in the same trench 5ch.S C" -I without sand and cover

    Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of

    Metre 26size not exceeding 25 sqmm direct in ground in the same trench in one tier horizontal formation including /' 13xcavation and refilling the trench etc. as required but excluding sand cushioning protective covering.

    87 of 1.25 MVCSGRT120W MV Cable laying upto 120 sqmm in the same trench 5ch.S without sand and cover

    Laying of one number additional PVC insulated and PVC sheathed / XLPE power cabl~ of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm Metre 29 direct in ground in the same trench in one tier ~ horizontal formation including excavation and refilling the trench etc. as required but excluding sand cushionino orotective coverino.

    89 of 3.2 CSRMCC Cable route indicator CC type 5ch.S Supplying and making cable route marker with cement

    concrete 1 :2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) of size 60 cm x Each 113 60 cm at the bottom and to 50 cm x 50 cm at the top )(with a thickness of 10 cm including inscription duly engraved as required.

    90 of 3.3 CSRMGI Cable route i~ator GI type 5ch.S Supplying and Kl~ cable route marker with 10 cm x

    10 cm 5 mm thick G.I plate with inscription there on, Each 157

    bolted, welded to 35 mm 35 mm x 6 mm angle iron, 60 {'cm long and fixing the same in ground as required.

    91 of 4.1 MVET LV I MV Cable end termination 5ch.S Supplying and making end termination with brass

    compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required.

    4.1.~"~ 2 x 25 sqmm Each 119 l.r-4.1.12 3 x 70 sgmm Each 169 Jc

    92 of 4.2 MVOJ LV I MV out door end termination 5ch.S Supplying and making out door end termination with

    brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required.

    4.2.2 2 x25 sqmm Each 294 4.2.9 . 3 x 70 sqmm Each ' 357

    93 of 4.3 MV51 LV I MV Cable straight through jointing 5ch.S Supplying and making straight through joint with cast

    resin compound including ferrules and other jointing materials for the following size of PVC insulated and PVC sheathed I XLPE aluminum conductor cable of

    ' D 1.1 kV grade as required.

    4.3.2 2 x 25 sqmm Each 689-V '" ~ ....-".

    Akkella P Sarma TJayam1 DyCEE(P) I CORE I ALD Schedule C DyCEE I RE I MS

    V~

    ,.p~

  • 4

    # CPWD Code unless mentioned otherwise

    Description of work . Unit Rate

    4.3.9 3 X 70 sqmm Each 786 (( 49 of Sch.A

    RE.OHE Sch.17.a G.I. earth pipe electrode Supply and erection of single earth electrode.

    each 1191 /'

    50 of Sch.A

    RE.OHE Sch.17.E Supply and erection of 8 SWG GI wire for earthing Metre 11 /' 51 of . 3.10 EAR6GGIWR 5 I L of 6 SWG GI wire Sch.A Supply and laying of 6 SWG GI wire at 0.50 metre

    below the ground level for conductor earth electrode Metre 16

    /,'"

    including soldering etc. as required . 52 of 3.11 EARGI25x5 5 I L of 25mm x Smm G.I. earth strip in ground

    I Sch.A Supply and laying of 25mm x 5 mm G.I. strip at 0.50

    metre below ground as strip earth electrode, including soldering etc. as required.

    Metre 45 , l'

    # 107 of 7.39 POLPIP50 5 I F 50 mm cable protection 50mm pipe on pole Sch.B Supplying and fixing of GI pipe of 50 mm dia ( nominal

    ) 3 metres length along the pole for protection of under I ground cable as required.

    .. each 603

    '"K 108 of 7.40 POLPIPSO 5 I F SO mm cable protection pipe on pole Sch.B Supplying and fixing of GI pipe of 80 mm dia ( nominal

    ) 3 metres length along the pole for protection of under ground cable as required.

    each 884

    ~ ;' 66 of Sch.A

    Rate analysis

    DELETEO Horizontal :t3~~En of HOPE Supply and I i H ~E i ze 150 mm di horizontal direct dn lIn tm meQ d. eEttE E [138 ~

    119 Rate analysis Erection testing and commissioning of AT panel Erection testing and commissioning of automatic color light signal in control distribution panel 30 Amps I 60

    No 395 ~.r--

    Am~s. 120 1.S WGPVCPT Point wiring in PVC conduct VJiJi;\ 'f"I ctlM) ~' F~ 11"-'> c!'\. ,

    Wiring for light pOint I fan point I exhaust fan point I call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface I recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required.

    121 1.8.3 Group C Point 397. -t-122 1.14 WGPVCSB Wiring for circuit I submain wiring in PVC conduit

    Wiring for circuit I submain wiring ~lIong with earth wire with the following sizes of PVC insulated copper

    " conductor, single core cable in surface I recessed PVC conduit as required.

    1.14.1 1.14.2 1.14.3

    2 x 1.5 sgmm + 1 x 1.5 sqmm earth wire 2 x2.5 sqmm + 1 x 2.5 sqmm earth wire 2 x 4 sqmm + 1 x 4 sqmm earth wire

    Metre Metre Metre

    71 t81 97 1.14.4 1.14.5

    2 x 6 sqmm + 1x 6 sqmm earth wire 2 x 10 sqmm + 1 x 10 sqmm earth wire

    Metre Metre

    127..r171 r

    Akkella P Sarma

    DyCEE(P) I CORE I ALD Schedule 'C' DyCEE I RE I MS

    ~~~.

    ~t.,

  • 5

    /~

    ~

    43 1

    .. / '

    ~ X

    # . CPWD Code unless mentioned otherwise

    Description of work Unit Rate

    123 1.29 LPACCPT Supplying and fixing 516 Amps plug in metal box Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5 I 6 amps socket outlet and 5 I 6 amps piano type switch, connection, painting etc. as required ( for light plugs to be used in non residential buildings ).

    each 102,124 1.30 PPACCPT Supplying and fixing 15 I 16 Amps plug in metal

    box Supplying and fixing metal box of 180 mm x 100 mm x 60mm deep ( nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5 I 6 & 15 I 16 amps socket outlet and 15 I 16 amps' piano type switch, connection painting etc. as required .

    each 161

    125 1.33 CREB Supply and fixing of ceiling rose Supply and fixing 3 pin, 5 amp, ceiling rose on the existing junction box I wooden block including connection etc. as required.

    each 1;'\

    126 1.34 BRHOLD Supply and fixing brass batten I angle holder Supply and fixing brass batten I angle holder including connection etc. as required.

    each 3;1

    127 1.35 ERINCFIT Erection of wall bracket I ceiling fittings Erection of wall bracket I ceiling fittings of all sizes and shapes containing up to two GLS lamps per fitting complete with all accessories inciuding connection etc. as required.

    each 19

    " 128 1.41 ITCFFSUR

    (INTERNAL) Erection of FL fitting Installation, testing and commissIoning of pre wired fluorescent fitting I compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling I wall, including connection with 1.5 sqmm FR PVC insulated copper conductor, Single core cable and earthing etc. as required.

    each /

    129 2.21

    2.21.1

    CUBTPN Supply and fixing of TPN switch32/63/100 Amps Providing and fixing following capacity TP & N disconnector fuse switch unit inside the existing cubicle panel board I on wall bracket with lSI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required.

    32 AmpTP & N each . 768 2.21.2 2.21.3

    63AmpTP & N each 1128 100 Amp TP & N each 2308 .y

    130 Rate analysiS Supply and fixing of MCCB switch 100 Amps Providing and fixing of MCCB 4 pole rating 100 Amps 10 KA in MS box of size 400 x 300 x 200 mm including drilling holes in cubicle connections etc. as required.

    panel, making Each 1869 >(

    ~ ~r-.. ..0,., ~ ~-Akkella P Sarma ~ DyCEE(P) I CORE I ALD SChedUle'~ DyCEE I RE I MS

    Vetted

    "'~ .. 8,. 4F~ ~.. ?n:;-

  • 1

    Schedule:D Internal Wiring Of Residential, Service Buildings Wiring Including Power Supply Arrangements

    # CPWDCode unless mentioned otherwise

    131 1.8 WGPVCPT

    1.8.1. 1.8.2. 1.8.3

    132 1.9 WGSTLPTTC

    133 1.10 WGPVCMOD

    1.10.1 1.10.2 1.10.3

    134 1.11 WGSTLMODTC

    135 1.12 WGPVCPP2

    r 'I ~ .L:J.... 1'/1 -,..

    ( to be read along with explanatory notes)

    Description of work

    Point wiring in pvc conduit with piano type switch Wiring for light pOint / fan point / exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required.

    Group A Group B Group C ...

    Twin control point wiring in PVC conduit with piano type switch Wiring for twin control light point with1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. Point wiring in PVC conduit with modular type switch Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate suitable GI box and earthing the pOint with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. Group A Group B Group C Twin control point wiring in PVC conduit with modular type switch Wiring of twin control light pOint with 1.5 sqmm FR PVC insulated copper conductor single core cable

    in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the pOint with 1.5.sqmm FR PVC insulated copper conductor single core cable etc. as required. Power plug wiring in PVC conduit (2 x 4 sqmm) Wiring for light / Power plug with 2 x 4 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC insulated copper conduit along 1 no. 4 sqmm FR PVC insulated copper conductor single core cable for loop earthing as required.

    Unit Rate

    Point 264 t Point 305

    . ~

    Point 397 -1

    KPoint 398 ,/

    Point 293 X Point 335 X~ Point 426-Y

    Point 45~V--

    Metre 97 rI" ~~

    DyCEE I RE I MS

    Akkella P Sarma

    DyCEE(P) I CORE I ALD Schedule 'D'

    v~tfld~

    iW~ . S f. ~FG\

    ~

  • 2

    ./

    # CPWD Code

    unless mentioned otherwise

    136 1.13 WGPVCPP4

    122 1.14 WGPVCSB of

    Sch. C

    1.14.1 1.14.2 1.14.3 1.14.4 1.14.5

    137 1.15 RW

    1.15.1 1.15.2 1.15.3

    138 d!) RWTC l Lb

    139 1.17 WGEC

    1.17.3 1.17.12. 1.17.21 1.17.30

    140 1.21 PVCCON

    1.21.1 1.21.2 1.21.3

    . ~

    Description of work

    IPower plug wiring in PVC conduit (4 x 4 sqrnm) Wiring for light / Power plug with 4 x 4 sqrnm FR PVC insulated copper conductor single core cable in surface / recessed PVC insulated copper conduit along 2 nos. 4 sqmm FR PVC insulated copper conductor single core cable for loop earthing as required .

    Circuit I submain wiring in PVC conduit Wiring for circuit / submain wiring along with earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. 2 x 1.5 sqmm+ 1 x 1.5 sqmm earth wire 2 x2.5 sqmm + 1 x 2.5 sqmm earth wire~ 2 x 4 sqmm + 1 x 4 sqmm earth wire 2 x 6 sgmm + 1x 6 sqmm earth wire c. 2 x 10 sqmm + 1 x 10 sqmm earth wire Point rewiring Rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable and 1.5 sqmm FR PVC insulated copper conductor single core cable as earth wire in existing surface / recessed steel/PVC conduit including dismantling as required.

    Group A Grou-.e B Group C Twin control point rewiring Rewiring for twin control light point with 1.5 sqmm FR PVC insulated copper conductor single core cable and 1.5. sqmm FR PVC insulated copper conductor single core cable as earth wire in existing surface / recessed steel/PVC conduit including dismantling as required.

    Wiring in the existing conduit Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface / recessed steel/PVC conduit as required. 3 x 1.5 sqmm 3 x 2.5 sqmm 3 x 4 s-.9mm 3 x 6 sqmm Supplying and fixing of PVC conduit Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit, as required. 20mm 25mm 32mm

    Unit Rate

    Metre 149 l>I.-

    ~ Metre 71-Metre 8J Metre 97 ~Metre 127 Metre 171 ~

    ~Point 125 Point 144 Point 200 ~

    Point 200 r

    Metre 32 ~

    Metre 43 -r--: Metre 58 ,;-.t Metre 83 --r

    Metre 41 /'

    Metre 47 ---Metre 56 ~ ,.,. ~ ~ -,;----

    Akkella P lfO'

    Sarma ~ DyCEE(P) I CORE I ALD SChedUle~ DyCEE I RE I MS

    Vetted,.... "

    ~r. AFA ~....b~

  • 3

    CPWD Code # . Description of work Unit Rate

    unless mentioned otherwise

    1.22141 MB S I F of steel metal box Supplying and fixing metal box of following sizes( nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75 mm x 75mm x 60 mm deep 1.22.1. each 55 k' 100mm x 1 OOmm x 60mm deep each 641.22.2.

    67150mm X 75mm X 60 mm deep each1.22.3. 150mm X 150mm X 60 mm deep each 871.22.4.

    105200mm x 150mm x 60mm deep each1.22.7 200mm x 250mm x 60mm deep 137each1.22.9 200 mm x 250 mm x 75mm deep each 143 IV1.22.10 200 mm x 300mm x 60 mm deep each 1541.22.13

    each 176

    142

    250 mm x 300 mm x 60 mm deeF 1.22.15 1.23 PTSWEB Supplying and fixing piano type switch and socket

    Supplying and fixing following piano type- switch / socket on the existing switch box I cover including connections etc. as required.

    5 16 amps switch 17each1.23.1 2 way 5/6 amps switch each 191.23.2 15/16 amp switch each 381.23.3 3 pin 5 / 6 amp socket outlet 21each1.23.4

    436Fin 15 / 16 amp socket outlet each1.23.5 Telephone socket outlet 27each1.23.6

    27

    143

    TV Antenna socket out let each1.23.7 1.24 MODSWEB Supplying and fixing modular type switch and

    socket. Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

    465 16 amps switch each1.24.1. 502 way 5 16 amps switch each1.24.2. 67 ~

    1.24,.4 15/16 amF switch each1.24.3

    64veach32in 5 16 amF socket outlet

    1016 pin 15/16 amp socket outlet each1.24.5

    Telephone socket outlet 611.24.6 each TV Antenna socket out let each 60

    144

    1.24.7 1.25 MODFREB Supply and fixing modular type electronic fan

    regulator Supply and fixing stepped type electronic fan regulator each 247 \' on the existing modular plate switch box including " connections but excluding modular type plate etc. as

    required.

    145 MODBPEB Supply and fixing modular blanking plate Supply and fixing modular blanking plate on the

    1.26

    each 20 ,/ lVexisting modular plate & switch box excluding modular

    I plate as required.

    ~

    W

    ~

    ~

    ~

    t

    ~

    t

    ~

    .

    ~

    ~ Akkella P Sarma DyCEE(P) I CORE I ALD Sch.dUI.~ DyCEE I RE I MS

    v' 6;: 1. g~

    ; ~ft . t .

  • # CPWD Code unless mentioned otherwise

    Description of work Unit Rate

    146 1.27 MODGIBXCP Supplying and fixing modules boxes, base & cover plate Supplying and fixing following size I modules, GI Box along with modular base & cover plate for modular switches in recess etc. as reauired.

    1.27.1. 1 or 2 Module (75mm x 75mm) each 88 1.27.2. 4 module ( 125mm x 75mm) each 113 1.27.3 6 module (200mm x 75mm ) each 153 1.27.4 8 module(125mm x 125mm) each 177 1.27.5 12 module (200 mm x 150 mm) each

    123 of

    Sch. C

    1.29 LPACCPT S I F light plug point 5 A piano type in metal box Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5 I 6 amps socket outlet and 5 I 6 amps piano type switch, connection, painting etc. as required ( for light plugs to be used in non residential buildings).

    each 102

    124 of

    Sch. C

    1.30 PPACCPT S I F light plug 15 A point piano type in metal box Supplying and fixing metal box of 180 mm x 100 mm x 60mm deep ( nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5 I 6 & 15 I 16 amps socket outlet and 15 I 16 amps piano type switch, connection painting etc. as required.

    each 161

    125 of

    Sch. C

    1.33 CREB Supply and fixing 3 pin, 5 amp, ceiling rose Supply and fixing 3 pin , 5 amp, ceiling rose on the existing junction box I wooden block including connection etc. as required.

    each 19

    126 of

    Sch. C

    1.34 BRHOLD Supply and fixing brass batten I angle holder Supply and fixing brass batten I angle holder including connection etc. as required.

    each 33

    127 of

    Sch. C

    1.35 ERINCFIT Erection of wall bracket I ceiling fittings Erection of wall bracket I ceiling fittings of all sizes and shapes containing up to two GLS lamps per fitting complete with all accessories including connection etc. as required.

    each 19

    '"

    147 1.36 STPEN300 Supplying and fixing stiff pendent with 300 mm long Supplying and fixing stiff pendent with 300 mm long 20mm dia 1.6 mm thick steel conduit, aluminum cast back plate and brass holder complete, including wiring the down rod with 1.5.sqmm FR PVC insulated copper conductor, reauired.

    single core cable and painting etc. as

    each 75 /'

    4

    ~ j;

    225 --r

    /'r1

    rr

    ~

    V

    V

    :v

    ~ Akkella P Sarma DyCEE(P) I CORE I ALD Schedule 'D' DyCEE I RE I MS

    tlettP

    .~ . !II'.~ ~ ~ r~\~ \

  • # CPWD Code

    unless mentioned otherwise Description of work Unit Rate

    148 1.37 STPEN 600 Supplying and fixing stiff pendent with 600 mm long Supplying and fixing stiff pendent with 600 mm long 20mm dia x 1.6 mm thick steel conduit, aluminum cast back plate and brass holder complete, including wiring the down rod with 1.5.sqmm FR PVC insulated, copper conductor, single core cable and painting etc. as required.

    each

    149 1.38 CALLBELL Supplying and fixing call bell 1buzzer Supplying and fixing call bell / buzzer suitable for DC I AC single phase, 230 volts, complete as required.

    each "

    150 1.39 TTCABCON S I F Twin twisted cable 161 0.2mm Providing and fixing plain 16 I 0.20 mm twin twisted flexible FR PVC insulated copper cable in polythene sleeve or conduit of size on the floor / wall, or side of the table / door etc. as required . ,.

    each

    128 . 1.41 ITCFFSUR Florescent fitting of (Internal) Installation, testing and commissioning of pre wired

    Sch. fluorescent fitting / compact fluorescent fitting of all C types, complete with all accessories and tube etc.

    directly on ceiling / wall, including connection with 1.5 sqmm FR PVC insulated copper conductor, single core cable and earthinQ etc. as required.

    each

    151 1.42 ITCFFDR (Internal)

    ITC fluorescent tube fitting with down rod Installation, testing and commissioning of prewired fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. including supply and fixing ball and ' socket arrangement, 2 nos down-rods of 20mm dia x 1.6mm thick steel conduit up to 30 cm length painting and wiring to the down rods and connection with 1.5.sqmm FR PVC insulated copper conductor, single core cable and earthing etc. as required/

    each

    152

    153

    1.43

    1.44

    EXTDR S 1F of extra down rod Providing and fixing of extra conduit down rod of 20 mm dia, 2 x 10 cm length wiring with 2 x1.S. sqmm FR PVC insulated copper conductor single core cable including painting etc. as required. ( Note: More than 10 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored ).

    each /'

    ITCCF S I F Ceiling fan Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length ( up to 30 cm ) with 1.5.sqmm FR PVC insulated copper conductor, single core cable etc. as required.

    each

    5

    26~ .

    43~

    126~

    17lY-'

    ~ Akkella P Sarma DyCEE I RE I MSDyCEE(P) I CORE I ALD

  • v

    # CPWD Code unless mentioned otherwise

    Description of work Unit Rate

    154 1.46 ITCFR 5 I F resistance type ceiling fan regulator Installation, testing and commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5. sqmm FR PVC insulated copper conductor single core cable earthing the regulator etc. as required.

    each 2~ ./

    155 1.52 ITCEF450 Erection of exhaust fan Installation of exhaust fan upto 450 mm sweep in the existing opening including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.

    each 223 ,,/

    156 1.54 LOUSHEF Fixing of louvers I shutters for exhaust fan Extra for fixing the louvers I shutters complete with frame for a exhaust fan of all sizes.

    each ~ 157 2.21 CUBTPN 5 I F TP&N switch 32 to 400 Amps ,.

    Providing and fixing following capacity TP & N disconnector fuse switch unit inside the existing cubicle panel board with lSI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required.

    7682.21.1 32AmpTP & N each 2.21.2 63AmpTP & N each 1128 2.21.3 100AmpTP&N each 2308 2.21.4. 125 Amp TP & N each 2.21.5 160 Amps TP & N each 3175 2.21.6 200AmpTP &N each 2.21.7 320 Amps TP & N each 5479 2.21.8 400 Amps TP & N each 6731

    158 2.22 MCCB 5 I F of MCCB 100Amps to 800 Amps Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.

    2.22.1. 100 Amps 10 kA each 1613 2.22.2 100 Amps 16 kA ~ . each 2.22.3. 125 Amps 16 kA each 3592 2.22.4. 160 Amps 16 kA each 3932 2.22.5 200 Amp 16 kA each 42092.22.6 200 Amp 25 kA each 2.22.7 250 Amp 25 kA each 6524 2.22.8 250 Amp 35 kA each 8564 2.22.9 315 Amps 35 kA each 11631 2.22.10 400 Amps 35 kA each 11631 2.22.11. 500 Amp 35 kA each 12802 2.22.12. 630 Amp 35 kA each 12802 2.22.13 800 Amps 35 kA each 15726

    6

    ~

    ly

    ~

    2621 :r 3520 y

    X'

    y 2361 y

    ~

    5501 ;;

    ~

    ~

    X ;..r

    Akkella P Sarma ~ DyCEE I RE I MSDyCEE(P) I CORE I ALD

  • 7

    "

    # CPWD Code

    unless mentioned otherwise Description of work Unit Rate

    ~ ~ X'

    ;>(

    ~ j'

    W

    159 2.31 SPMCBDB S I F SP MCB DP Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface I recess complete with tinned cooper busbar, neutral bus bar, earth bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( but with out MCB I RCCB I isolator).

    2.31.1 4 way single door each 301 2.31.2 8 ways single door each 37'l 2.31.3 12 way single door each 464 2.31.4 16 way single door each 549 2.31.5 4 way double door each 450 2.31.6 8 way double door each 709 2.31.7 12 way double door each 746 2.31.8 16 way double door each 882

    160 2.33 TPMCBDB SI FTPMCBDB Supplying and fixing following way three pole and neutral sheet steel MCB distribution board 415 volts, on surface I recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( but without MCB I RCCB / Isolator ).

    2.33.1. 4 way, single door horizontal type each 820 2.33.2. 6 way, single door horizontal_type each 959

    ~

    ~ )0

    y

    v

    r;;

    .y

    2.33.3. 8 way single door horizontalJype each 1388 2.33.4 4 way double door horizontal type each --1311 2.33.5 6 way, double door horizontal type each 1634 2.33.6 8way, double door horizontal type each 16.03

    161 2.51 MCBB Supplying and fixing 5 Amps to 32 Amps Rating 240 volts B series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required.

    2.51.1 Single pole each 86 2.51.2. Single pole and neutral each 171 2.51.3. Triple pole each 273 2.51.4 Triple pole and neutral each 352

    162 2.54 MCBDPIS S I F DP MCB Isolator Supply and fixing of following rating double pole, 240 volts, isolator in the existing MCB DB complete with connections required.

    , testing and c9mm..issioning etc. as

    2.54.1. 40 Amps each 166 2.54.2. 63 Amps each 196

    Akkella P Sarma ~ DyCEE(P) I CORE I ALD Schedu'e 'D'~ DyCEE I RE I MS

    VeH. t... ~ Sr.4fA ~t;\O)

  • 8

    # CPWD Code unless mentioned otherwise

    163 2.55 MCBTPIS

    2.55.1 2.55.2 2.55.3

    164 2.56 RCCBSPN

    2.56.1 2.56.2 2.56.3

    165 2.57 RCCBTPN

    2.57.1 2.57.2. 2.57.3

    166 2.62 MCBDPSOC20

    167 Rate analysis

    168 Rate analysis 67 of 1.1 MVCBGR25 Sch.

    B

    Description of work Unit Rate

    S I F TP MCB Isolator Supplying and fixing following rating four pole 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required .

    ~40 amps each 345 63 amps each 362 100 amps each 460 .{"

    S I F SPN RCCB Supplying and fixing following rating, double pole ( single phase and neutral), 240 volts, residual current circuit breaker ( RCCB ) having a sensitivity current upto 300 mill amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

    25.Amps " each 949 (40 Amps each 1007 63 Amps each 1343 ~ S I FTPN RCCB Supplying and fixing following rating, four pole( three phase and neutral), 415 volts, residual current circuit breaker ( RCCB ) having a sensitivity current upto 300 mill amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required .

    25.Amps each 1168 W 40 Amps each 1208 ~63 Amps each 1426 S I F 20A SPN MGB with 20A plug & socket Supplying fixing 20 amps, 240 volts, SPN industrial type. Socket outlet, with 2 pole and earth metal enclosed plug top along with 20 Amps C series SP

    eac~ 520 rrMCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket out let and complete with connections testing and commissioning etc. as required. 1ISupply and fixing of MS box and fixing Energy

    1.-Sh" Meter each --@ Supply and fixing of MS box of size 400 x 300 x 200 mm and fixing of Enemy Meter 10 120AmJ)s. }Fixing of Geyser by using Rail bolt of suitable size. each 395 MV Cable laying upto 25 sqmm in ground Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size

    Metre ,/ /" 85 /' not exceeding 25 sqmm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as required ,

    ~ Akkella P Sarma DyCEE(P) I CORE I ALD Schedule 'D'~ DyCEE I RE I MS

    V~'""

  • # CPWD Code unless mentioned otherwise

    Description of work . Unit Rate

    68 of 5ch.

    B

    1.2 MVCBGR120 MV Cable laying upto 120 sqmm in ground Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    Metre

    69 of 5ch.

    B

    1.3 MVCBGR400 MV Cable laying upto 400 sqrnm in ground Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    Metre

    70 of 5ch.

    B

    1.4 MVCBGRT25 MY Cable laying upto 25 sqmm in the same trench Laying of one number additional PVC insullted and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    Metre 57

    71 of 5ch.

    B

    1.5 MVCBGRT120 MY Cable laying upto 120 sqmm in the same trench Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the, trench etc. as required.

    Metre

    72 of 5ch.

    B

    1.6 MVCBGRT400 MV Cable laying. up to 400 sqmm in the same trench Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.

    Metre

    73 of 5ch.

    v B

    1.7 MVCBPIP25 MV Cable laying up to 25 sqrnm in pipe Laying of one number of PVC insulated and PVC sheathed I XLPE power cable 1,1 kV grade of size not exceeding 25 sqmm in the existing RCC I HUME I STONEWARE I METAL pipe as required.

    Metre

    74 of 5ch.

    B

    1.8 MVCBPIP400 MV Cable laying up to 400 sqrnm in pipe Laying of one number of PVC insulated and PVC sheathed I XLPE power cable 1.1 kV grade of size exceeding 25 sqmm but not exceeding 400 sqmm in the eXisting RCC I HUME I STONEWARE I METAL pipe as required .

    Metre

    9

    9~V

    97M

    ~

    60/

    63~

    15/

    21 ,/

    Akkella P Sarma =r:.::LDyCEE(P) I CORE I ALD Schedule 'D' / DyCEE I RE I MS

    Vett ...., ~V I .

  • 10

    CPWD Code Unit RateDescription of work# unless mentioned otherwise

    H

    MVCBOD25 Sch.

    B

    75 of 1.9

    76 of Sch.

    B

    , 77 of Sch.

    B

    MVCBOD4001.10

    MVCBSUR251.11

    MVCBSUR120 Sch.

    B

    78 of 1.12

    79 of 1.13 MVCBSlIR400 Sch.

    B

    80 of 1.21 MVCB~R25W Sch.

    B

    81 of Sch.

    B

    1.21.a Rate analysis arrived from CPWD

    Code 1.21 & RE/S&T Sch.

    0208

    /

    82 of 1.22 MVCBGR120W Sch.

    B

    MV Cable laying up to 25 sqmm in open duct Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size not exceeding 25 sqmm in the masonry open duct as required. MV Cable laying up to 400 sqmm in open duct Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 400 sqmm in the masonry open duct as required. MV Cable laying up to 25 sqmm on surface Laying and fixing of one number PVC insulated and PVC sheathed J XLPE Aluminum conductor cable of Metre 31 1.1 kV grade of size not exceeding 25 sqmm on

    ~__~______~____________-Fs~u~rt~ac~e~a~s~ffi~qu~iffi~d~.______________________~______ -+______~ MV Cable laying up to 120 sqmm on surface Laying and fixing of one number PVC insulated and PVC sheathed I XLPE Aluminum conductor cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm on surtace as required.

    MV Cable laying up to 400 sqmm in surface Laying and fixing of one number PVC insulated and PVC sheathed I XLPE Aluminum conductor cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 400 sqmm on surtace as required.

    MV Cable laying up to 25 sqmm in ground without sand and cover Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size NOT exceeding 25 sqmm direct in ground including excavation, and refilling the trench etc. as required. but excluding sand cushioning and protective covering.

    MV Cable laying up to 25 sqmm in ground in 150 mm dia RCC pipe Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size not exceeding 25 sqmm direct in 150 mm dia RCC pipe including excavation, and refilling the trench etc. as required but excluding sand cushioning and protective covering.

    MV Cable laying upto 120 sqmm In ground without sand and cover Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground including excavation, and refilling the trench etc. as required. but excluding sand cushioning and orotective coverina.

    Metre

    Metre 17~

    Metre 59~

    Metre 61/

    , Metre 49/

    I

    Metre 276 /

    Metre 55V

    Akkella P Sarma ~ OyCEE(P) I CORE I ALD Schedule '0' / DyCEE I RE I MS

    . .~~ Ve":l$l1

    ~ i . f'" . '

  • # CPWD Code unless mentioned otherwise

    Description of work Unit Rate

    83 of 1.22.a Rate analysis MV Cable laying up to 120 sqmm in ground in 150 5ch. arrived from CPWD mm dia RCC pipe

    B Code 1.22 & Laying of one number PVC insulated and PVC RE/5&T 5ch. sheathed I XLPE power cable of 1.1 kV grade of size

    0208 exceeding 120 sqmm but not exceeding 400 sqmm direct in 150 mm dia RCC pipe including excavation, sand cushioning protective covering and refilling the trench etc. as required. but excluding sand cushioning and protective coverinQ .

    Metre

    84 of 8ch.

    B

    1.23 MVCBGR400W MV Cable laying up to 400 sqmm in ground without sand and cover Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground including excavation, sand cushioning protective covering and refilling the trench etc. as required but excluding sand cushioning and protective covering.

    Metre

    85 of 5ch.

    B

    1.23a Rate analysis MV Cable laying up to 400 sqmm in ground in 150 arrived from CPWD dia RCC pipe

    Code 1.23 & Laying of one number PVC insulated and PVC RE/5&T 5ch. sheathed I XLPE power cable of 1.1 kV grade of size

    0208 exceeding 25 sqmm but not exceeding 120 sqmm direct in 150 mm dia RCC pipe including excavation, and refilling the trench etc. as required but excluding sand cushioning and protective covering.

    Metre

    86 of 5ch.

    B

    1.24 MVCBGRT25W MV Cable laying up to 25 sqmm in the same trench without sand and cover Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size not exceeding 25 sqmm direct in ground in the same trench in one tier horizontal formation including excavation, and refilling the trench etc. as required but excluding sand cushioning protective covering.

    Metre

    87 of 5ch.

    B

    1.25 MVCBGRT120W MV Cable laying up to 120 sqmm in the same trench without sand and cover Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 25 sqmm but not exceeding 120 sqmm direct in ground in the same trench in one tier horizontal formation including excavation, and refilling the trench etc. as required but excluding sand cushioninQ protective coverinQ.

    Metre 29

    88 of 5ch.

    B

    1.26 MVCBGRT400W MV Cable laying up to 400 sqmm in the same trench without sand and cover Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of size exceeding 120 sqmm but not exceeding 400 sqmm direct in ground in the same trench in one tier horizontal formation including excavation, and refilling the trench etc. as required but excluding sand cushioningJ2l"otective coverinQ.

    Metre 32

    11