SONIC 4000 - PMK 4000 Datasheet.pdfPMK‘s PS-02 and PS-03 Power Supplies use a Lemosa connector...

4
Probing Solutions. Made in Germany. EN Datasheet High Impedance Active Probe SONIC 4000

Transcript of SONIC 4000 - PMK 4000 Datasheet.pdfPMK‘s PS-02 and PS-03 Power Supplies use a Lemosa connector...

Page 1: SONIC 4000 - PMK 4000 Datasheet.pdfPMK‘s PS-02 and PS-03 Power Supplies use a Lemosa connector Type 304 for Power- as well as Dataline connection. With the free software „PMK Remote

Probing Solutions. Made in Germany.

EN

Datasheet

High Impedance Active Probe

SONIC 4000

Page 2: SONIC 4000 - PMK 4000 Datasheet.pdfPMK‘s PS-02 and PS-03 Power Supplies use a Lemosa connector Type 304 for Power- as well as Dataline connection. With the free software „PMK Remote

SONIC 4000

Order-Number 884-000-000

Electrical Specifications

Attenuation Ratio ( (± 2 % at DC) (1) 10:1

Probe Bandwidth (-3 dB) 4 GHz

Input Dynamic Range ± 8 V

Maximum Rated Input Voltage 20 V

Input Resistance (System) 1 MΩ

Input Capacitance (System) 0.6 pF

Input Coupling of the Measuring Instrument 50 MΩ

Mechanical Specifications

Weight (probe only) 107 g

Cable Length 1.3 m

Probe Input Sockets 0.64 mm square / 0.8 mm round

Output Connectors BNC (SMA available on request)

(1) Connected to oscilloscope with an input impedance of 1 MΩ ± 1 %.

Environmental Specifications

Altitudeoperating up to 2000 m

non-operating up to 15000 m

Temperature Rangeoperating 0° C to +45° C

non-operating -40° C to +71° C

Maximum Relative Humidityoperating 80 % relative humidity for temperatures up to +31° C, decreasing linearly to 40 % at +45° C

non-operating 95 % relative humidity for temperatures up to +40° C

Max. Input Voltage and Dynamic Measuring Range

The Sonic active probe is protected against electro-static-discharge voltage (ESD). However, applying input-voltages outside the specified limits can result in destruction of the probe´s amplifier.

SONIC 4000 DATASHEET

The maximum amplitude of the applied signal may not exceed the limits of the graph below, to avoid input linearity errors and damage to the probe.

Power Supply

PMK‘s PS-02 and PS-03 Power Supplies use a Lemosa connector Type 304 for Power- as well as Dataline connection. With the free software „PMK Remote Control“ you can readout and adjust PMKs Active Probes remotely via these Power Supplies like a Hub. Please find the Pin Assignment below:

The maximum amplitude of the applied signal may not exceed the limits of the graph below, to avoid damage to the probe.

Please note, that any noise of the supply voltage influences the noise of the signal in general. We therefore recommend using a PMK PS-02 or PS-03 Power Supply.

2 1

3 4PIN Assignment1 (-9 V)2 (+9V)3 SDA4 SCL

Volta

ge [V

] AC

pea

k

Frequency [Hz]

Input Voltage vs. Frequency SONIC 4000 RF

1

10

100

1G 10G100M10M1M

Dynamic Measuring Range Maximum Input Voltage

Volta

ge [

V] A

C p

eak

Input Voltage vs. Frequency Sonic 4000

Frequency [Hz]

|Z| [

Ohm

]

Sonic 4000 Input Impedance

f / Hz

Page 3: SONIC 4000 - PMK 4000 Datasheet.pdfPMK‘s PS-02 and PS-03 Power Supplies use a Lemosa connector Type 304 for Power- as well as Dataline connection. With the free software „PMK Remote

Probe Accessories

Use ground lead only for connections to earth ground. The accessories provided with the probe have been safety tested. Do not use any other accessories than those "originally" provided.

Scope of Delivery

SONIC 4000 DATASHEET

890-020-916Marker Bands 4 x 4 colors

890-500-800L-In Adapter

890-720-840Y-Leitung to

0.8 mm sockets

P25-0 /-2Pico Hook™black / red

890-400-808Ground Lead 7 cm

890-400-809Ground Lead 13 cm

890-400-803Ground Lead 90° 5 cm

890-400-804Ground Lead 90° 10 cm

890-800-001Sonic Spring Tip x5

890-800-000Sonicic Solid Tip x5

890-100-150self-adhesive Cu-pads x10

(2 x 2 cm)

890-400-813Ground Leaf

890-502-130QFP IC-Clips 13 mm long

up to 0.5 mm pitch(1 Pair, yellow/green)

890-502-000QFP IC-Clips 13 mm short

up to 0.5 mm pitch(1 Pair, yellow/green)

890-400-811Z-Ground

890-400-812Ground Blade

891-010-814PCB Adapter Sonic x10

891-025-814PCB Adapter Sonic x25

891-010-8102.54 mm Adapter Sonic x10

891-025-8102.54 mm Adapter Sonic x25

- PS-02 (2 Channel) 889-09V-PS2- PS-02-L (2 Channel with Lan) 889-09V-PS2-L- PS-03 (4 Channel) 889-09V-PS3- PS-03-L (4 Channel with Lan) 889-09V-PS3-L- AP-01 (Battery Pack, 1 Channel) 889-09V-AP01

Item Qty Item Qty

Ground Blade 1 Case 1

Ground Lead 7 cm 1 Calibration Certificate 1

Ground Lead 13 cm 1 2-Footer (black) 1

Ground Lead 90° 5 cm 1 Probe 1

Ground Lead 90° 10 cm 1 Self adhesive Cu Pad (2 x 2 cm) 2

Ground Leaf 3 Solid Tip 3

Instruction Manual 1 Pair of SMD Test Grabbers (black & red) 1

L-In Adapter 1 Pair of QFP IC-Clips (short, yellow & green) 1

Set Marker bands (4 x 4 colors) 1 Pair of PicohooksTM (black & red) 1

PCB Adapter 5 Y-Lead Adapter to 0.8 mm sockets 1

2.54 mm Adapter Sonic 2 - -

Power Supplies*

Order No. Item Order No. Item

889-09V-PS2 PS-02 (2 Channel) 889-09V-AP01 AP-01 ( Battery pack, 1 Channel)

889-09V-PS2-L PS-02-L (2 Channel with Lan) 890-520-900 Power Supply Cable (0.5 m)**

889-09V-PS3 PS-03 (4 Channel) 890-520-915 Power Supply Cable (1.5 m)

889-09V-PS3-L PS-03-L (4 Channel with Lan) - -

* The Power Supplies needs to be ordered separately. ** The Power Supply Cable (0.5 m), is included in all Power Supplies as standard.

Page 4: SONIC 4000 - PMK 4000 Datasheet.pdfPMK‘s PS-02 and PS-03 Power Supplies use a Lemosa connector Type 304 for Power- as well as Dataline connection. With the free software „PMK Remote

Copyright © 2020 PMK GmbH All rights reserved.

Information in this publication supersedes that in all previously published material. Specifications are subject to change without notice.

D84-SONIC-000 Revision Mar. 2020

PMK Mess- und Kommunikationstechnik GmbH Koenigsteiner Str. 98

65812 Bad Soden, Germany

Tel: +49 (0) 6196 5927 - 930 Internet: www.pmk.de Fax: +49 (0) 6196 5927 - 939 E-Mail: [email protected]

Manufacturer